HomeMy WebLinkAboutEPL Display CardFORM R405-2014
\PERFORMANCE
ENERGY
LEVEL
EPL
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*
= 99
The lower the EnergyPerformance Index, the more efficient the home.
w
Lot Al Venture Harbor, Ft. Pierce, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=7.5
1278.00 ft2
b. Frame - Wood, Exterior
R=13.0
225.00 ftZ
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
2 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
Yes a. Under Attic (Vented)
R=30.0
1577.00 ft2
6. Conditioned floor area (ft2)
1577 b. N/A
R=
ft2
7. Windows** Description
Area c. N/A
R=
ft2
a.
a. U-Factor: Dbl, U=0.28
11. Ducts
144.00 ft2 a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 315.4
SHGC: SHGC=0.29
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
37.0 SEER:18.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
37.0
COP:1.00
Area Weighted Average Overhang Depth:
0.861 ft.
Area Weighted Average SHGC:
0.290
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Electric
a. Raised Floor R=19.0 1577.00 ft2EF:
0.99
b. N/A R=
ft2
b. Conservation features
c. N/A R=
ft2
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code c pliant features.
Builder Signature: / i�c Date:�fz
y�1iE STq?oAt•
(i Al
coD WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservati •RM I o f e
i
5/9/2016 1:28 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant S - DPgeYof 1
FORM R405-2014
'
PROJECT
_
1
Title:
Building Type:
Owner:
`# of Units:
Builder Name:
Permit Office:
:,Jurisdiction:
Family Type:
New/Existing:
Comment:
Bennett Residence
User
Bennett
1
St. Lucie County
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 1577
Total Stories: 1
Worst Case: Yes
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/SubDivision:
PlatBook:
Street: Lot Al Venture Harbor
County: St. Lucie
City, State, Zip: Ft. Pierce,
FL,
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
1577 14193
SPACES
Number
Name
Area Volume . Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
1577 14193 Yes 1
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space R-Value
Area
Tile Wood Carpet
1 Raised Floor
Main ---- ----
1577 ft2
19 0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Gable or shed
Metal 1708 ft2 328 ft2 Medium
0.96
No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1577 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1577 ft2 0.11 Wood
5/9/20161:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
'
WALLS
Adjacent Cavity Width
U Type Space R-Value Ft In Ft
Height
In Area
Sheathing Framing Solar
RAW-*_Flacti
Below
°
1
N
Exterior Concrete Block - Int Insul Main
7.5 33 9
297.0 ft2
0 0.75
0
2
NE
Exterior Concrete Block - Int Insul Main
7.5 28 9
252.0 ft2
0 0.75
0
3
S
Exterior Frame - Wood Main
13 25 9
225.0 ft2
0.23 0.75
0
4
E
Exterior Concrete Block - Int Insul Main
7.5 16 9
144.0 ft2
0 0.75
0
5
SE
Exterior Concrete Block - Int Insul Main
7.5 28 9
252.0 ft2
0 0.75
0
6
W
Exterior Concrete Block - Int Insul Main
7.5 37 9
333.0 ft2
0 0.75
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N Wood Main
None
.46 3
7
21 ft2
2
W Wood Main
None
.46 3
7
21 ft2
WINDOWS
Orientation shown is the entered orientation (_> changed to Worst Case.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1
W 6 Metal Double (Tinted) Yes
0.28 0.29
10.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
2
N 1 Metal Double (Tinted) Yes
0.28 0.29
20.0 ft2 0 ft 0 in
0 ft 0 in
Drapes/blinds
None
3
NE 2 Metal Double (Tinted) Yes
0.28 0.29
40.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
4
NE 2 Metal Double (Tinted) Yes
0.28 0.29
28.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
5
E 4 Metal Double (Tinted) Yes
0.28 0.29
20.6 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
6
SE 5 Metal Double (Tinted) Yes
0.28 0.29
6.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
7
SE 5 Metal Double (Tinted) Yes
0.28 0.29
20.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
382.8 ft2 382.8 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse . Proposed ACH(50) .000286
1182.8 64.93 122.11 .2087
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None
COPA
37 kBtu/hr
1
sys#1
5/9/2016 1:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
Split
SEER: 18
37 kBtu/hr
1110 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.99 40 gal
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
-- Supply —
- Return —
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 315.4 ft
Attic
78.85 ft Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programabl[eThermostat:
Ceiling Fans:
��Y
Heat ng H Jan H Feb
HX Mar
Apr
M:yri
Jun Jul
May
Aug
ri
Sep
ri
0
Oct
Nov
Nov
Dec
DecVenting
[[ ]] Jan [[ ]] Feb
Mar
LXj Jun Jul
Aug
Sep
X
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (VVD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
5/9/20161:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4