HomeMy WebLinkAboutEPL Display CardFORM R405-2014 \PERFORMANCE ENERGY LEVEL EPL DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. w Lot Al Venture Harbor, Ft. Pierce, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=7.5 1278.00 ft2 b. Frame - Wood, Exterior R=13.0 225.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1577.00 ft2 6. Conditioned floor area (ft2) 1577 b. N/A R= ft2 7. Windows** Description Area c. N/A R= ft2 a. a. U-Factor: Dbl, U=0.28 11. Ducts 144.00 ft2 a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 315.4 SHGC: SHGC=0.29 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 37.0 SEER:18.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 37.0 COP:1.00 Area Weighted Average Overhang Depth: 0.861 ft. Area Weighted Average SHGC: 0.290 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Electric a. Raised Floor R=19.0 1577.00 ft2EF: 0.99 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code c pliant features. Builder Signature: / i�c Date:�fz y�1iE STq?oAt• (i Al coD WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservati •RM I o f e i 5/9/2016 1:28 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant S - DPgeYof 1 FORM R405-2014 ' PROJECT _ 1 Title: Building Type: Owner: `# of Units: Builder Name: Permit Office: :,Jurisdiction: Family Type: New/Existing: Comment: Bennett Residence User Bennett 1 St. Lucie County Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1577 Total Stories: 1 Worst Case: Yes Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/SubDivision: PlatBook: Street: Lot Al Venture Harbor County: St. Lucie City, State, Zip: Ft. Pierce, FL, CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1577 14193 SPACES Number Name Area Volume . Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1577 14193 Yes 1 2 1 Yes Yes Yes FLOORS # Floor Type Space R-Value Area Tile Wood Carpet 1 Raised Floor Main ---- ---- 1577 ft2 19 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Gable or shed Metal 1708 ft2 328 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1577 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1577 ft2 0.11 Wood 5/9/20161:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 ' WALLS Adjacent Cavity Width U Type Space R-Value Ft In Ft Height In Area Sheathing Framing Solar RAW-*_Flacti Below ° 1 N Exterior Concrete Block - Int Insul Main 7.5 33 9 297.0 ft2 0 0.75 0 2 NE Exterior Concrete Block - Int Insul Main 7.5 28 9 252.0 ft2 0 0.75 0 3 S Exterior Frame - Wood Main 13 25 9 225.0 ft2 0.23 0.75 0 4 E Exterior Concrete Block - Int Insul Main 7.5 16 9 144.0 ft2 0 0.75 0 5 SE Exterior Concrete Block - Int Insul Main 7.5 28 9 252.0 ft2 0 0.75 0 6 W Exterior Concrete Block - Int Insul Main 7.5 37 9 333.0 ft2 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Main None .46 3 7 21 ft2 2 W Wood Main None .46 3 7 21 ft2 WINDOWS Orientation shown is the entered orientation (_> changed to Worst Case. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 6 Metal Double (Tinted) Yes 0.28 0.29 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 2 N 1 Metal Double (Tinted) Yes 0.28 0.29 20.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 3 NE 2 Metal Double (Tinted) Yes 0.28 0.29 40.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 NE 2 Metal Double (Tinted) Yes 0.28 0.29 28.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 E 4 Metal Double (Tinted) Yes 0.28 0.29 20.6 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 SE 5 Metal Double (Tinted) Yes 0.28 0.29 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 SE 5 Metal Double (Tinted) Yes 0.28 0.29 20.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse . Proposed ACH(50) .000286 1182.8 64.93 122.11 .2087 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 37 kBtu/hr 1 sys#1 5/9/2016 1:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 18 37 kBtu/hr 1110 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.99 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply — - Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 315.4 ft Attic 78.85 ft Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[eThermostat: Ceiling Fans: ��Y Heat ng H Jan H Feb HX Mar Apr M:yri Jun Jul May Aug ri Sep ri 0 Oct Nov Nov Dec DecVenting [[ ]] Jan [[ ]] Feb Mar LXj Jun Jul Aug Sep X Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/9/20161:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4