Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 8-19-16FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CO STRUCTION M-;Ar rno.,nr+mcnt nf Rr rsinPss and Professional Requlation - Residential Perfor . - e Method a Project Name: Bennett Residence Builder Name: JWN Builders 49 ` A Street: 10751 S Ocean Dr. Lot Al Permit Office: Number�6# f St Lucie t;y 460i1(831� City, State, Zip: Jensen Beach, FL , Permit Owner: Bennett Residence Jurisdiction: County:: 611000 St. Lucie (Florida Climate Zone 2 ) Design Location: FL, Fort Pierce 1. New construction or epsting From Plans New ( ) 9. Wall Types (1625.3 sqft.) a. Concrete Block - Int Insul, Exterior Insulation R=4.2 Area 1376.30 if 2. Single family or multiple family Single-family 1 b. Frame - Wood, Adjacent R=13.0 249.00 ftz 3. Number of units, if multiple family 1 c. N/A R= fP 2 d. N/A R= ftz 4. Number of Bedrooms 10. Ceiling Types (1577.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1577.00 ftz 6. Conditioned floor area above grade (ftz) 1577 b. N/A R= R= ftz ft2 c. N/A Conditioned floor area below grade (ftz) 0 11. Ducts R ftz 7. Windows(225.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Dbl, U=0.24 225.00 ftz SHGC: SHGC=0.27 12. Cooling systems kBtulhr Efficiency b. U-Factor. N/A ftz a. Central Unit 28.6 SEER:16.00 SHGC: c. U-Factor: N/A 13. Heating systems kBtuhrr Efficiency SHGC: N/A ftz a. Electric Heat Pump 27.6 HSPF:9.00 d. U-Factor: SHGC: Area Weighted Average Overhang Depth: 1.000 ft. 14. Hot water systems Area Weighted Average SHGC: 0.270 a. Electric p� Ca 40 gallons 8. Floor Types (1577.0 sqft.) Insulation Area EF: 0.980 a. Raised Floor R=19.0 1577.00 ftz b. Conservation features b. N/A R= ft2 None c. N/A R= fF 15. Credits CF, Pstat Total Proposed Modified Loads: 52.68 PASS Glass/Floor Area: 0.143 Total Baseline Loads: 58.61 I hereby certify that the plans and specifications covered by this calculation are in compli •th t Florida Energy Code. � / PREPARED BY' '�- DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNERIAGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure quauries as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. doors, - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report cRin tested in accordance with Section 803 of RESNET Standards, is not greater than 0.000 w e ufy 811812016 4:05 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4