HomeMy WebLinkAboutInsulation Installation CertificateFeb 2717 01:11 p JWN Construction 772-871-9500 d\k3 INSULATION INSTALLATION CERTIFICATE TD: JWN Construction LOT, BLOCK: SECTION: JOB#; 108795 JOB NAME- Bennet Res - Lot 10 PA FEB 2 7 201? PERMIT WGi St. Lucie County, FL JOB ADDRESS: 10751 S Ocean Dr The imdersiped hereby certifies that insulation has been installed at the above described priogcrty as fellows; 1. Exterior CBS walls have been insulated with ................... _....... Check one ( ) Spray on cellulose to a thickness of NJA inches, which thickness, according to the { ) Fiberglass blankets manufacturer, CFI ( ) Aluminum Foil Density NIA will yield an "It" value of 10 0 Block Fill Exterior Frame walls have been insulated with ..._ .......................Check one ( ) Spray on cellulose to a thickness of inches, which thickness, according to the ( ) Fiberglass blankets manufacturer, ( ) Aluminum Foil Density wA will yield an "R" value of ( ) Other Spray Foam 2. Main Ceilings have been insulated with . ...................._..Check one ( ) Fiberglass blankets to a thickness of8 inches, which thickness, according to the ( ) Fiberglass loose fit I manufacturer, SES Sucraseal () Aluminum Foil Density WA will yield an "R" value of 30 Spray Foam Ceilings Cathedral have been insulated with ........ ................Check one ( ) Fiberglass blankets to a thickness of inches, which thickness, according to the ( ) Fiberglass loose fill manufacturer, () Aluminum Foil Density N/A will yield an "R" value of () Other Wfulow 3. Interior knee walls have been insulated with ................................Check one ( ) Fiberglass blankets to a thickness of g inches, which thickness, according to the ( ) Polyurethane manufacturer, SES Sucraseal ( ) Spray on cellulose Density WA will yield an "R" value of 30 W Other Spray Foam 4. Garage partition walls of conditioned living areas have been insulated with.. ............ .,,_.. _...._. ... ................. ..Check -one 0() Fiberglass blankets to a thickness of 6.25 inches, which thickness, according to the ( ) Spray on cellulose manufacturer, Certainteed ( ) Polyurethane Density WA will yield an'V value of 19 ( ) Other Aluminum Foil MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating different tenants shall be insulated as follows - Fratne/Metal stud walls R-I I (Min.); CBS or Concrete walls R-3 (Min.); by Energy Code requirements. See Energy Code Rev. 1/97, paragraph 903.2(b), on page 9-17, latest edition. These "minimums levels of insulation" are not included in the Energy Calculations: but shall be installed in the field. NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F. (lb/tt3) average of three (3) "DRY SAMPLES' of actual installlaat[io MER Enterprises LLC Insulation Contractor Insulation Contractor Signature MCIN6231 Insulation Contractor's CC# l2/16!16 Date of Certification Builder's Name - Builder's CC# N11110c r „unrp KELLY L YOUNG notary Public - Slate of Florida 61y Comm. Expires Jul t, 2018 Commission # FF 138101