HomeMy WebLinkAbout9' HDP20 W6 fl#BCIS Home I Log In € User Registration ' Hot Topics ( Submit Surcharge I Stats & Facts I Publications Contact Us BCIS Site Map
i rdx
�' Product Approval
USER: Public User
## Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL16107-R14
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Mason, OH 45040
(513)770-6062
mwesterfield@clopay.com
Scott Hamilton
shamilton@clopay.com
Exterior Doors
Sectional Exterior Door Assemblies
Evaluation Report from a Florida Registered Architect or a Licensed
Engineer
Evaluation Report - Hardcopy Received
Scott Hamilton
PE-63286
Intertek Testing Services NA, Inc. - QA Entity
12/31/2023
Gary Pfuehler
Validation Checklist - Hardcopy Received
GaCy Pfuehl rodf
FL16107 R14 COI Statem
ScottHamil on 120424.pdf
Standard
ANSI/DASMA 108
ANSI/DASMA 115
ASTM E1886
ASTM E1996
ASTM E330
TAS 201
TAS 202
TAS 203
Florida Licensed Professional Engineer or Architect
FL16107 R14 Eauiv 20200812 - FBC - ASTM 1886-1996 eq i4 iv.pd
Method 1 Option D
02/16/2021
Links Search
2002
1994
1994
1994
Professiona
Date Validated 02/16/2021
Date Pending FBC Approval 02/22/2021
Date Approved 04/13/2021
Summary of Products
Go to Page
..... ..... ............................. ................... ........................ ........ ............. :..........................................
Page 3/3
................... ........................................................... .................................. .................. .................. ....................................... ............................................ ................................ ... ......... ......................................
F 'Model, Number or Name Description
....................................................... .
16107.41 141 W6-09 DSIU-1F171: 9200, 9201, 9203, 1 Double -skin Insulated PUR (exterior skin 27 ga. min.; interior
skin 27 ga.
HDP20, HDPF20, HDPL20, 7200, 7201, min.) Single -Car (up to 9'0" wide) WINDCODE® W6 Garage
Door with
7203, 8200, 8201, 8203 Optional Impact -Resistant Lites
.............. .............:........................................ ..... .... ........................ ............... ..... ....... .............. ......... ....................... .......................................................
Limits of Use ! Installation Instructions
....................................................
! Approved for use in HVHZ: Yes I FL16107 R14 II 104184-A-Rev05-pi f
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes E Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF !Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with EL16107 R14 AE CDpC 140220-a pdf
optional impact -resistant glazing are impact -resistant (large missile Created by Independent Third Party: No
impact).
......................
16107.42 42 W6-09 DSIU-1F171: 9200, 9201, 9203, i Double -skin Insulated PUR (exterior skin 27 ga. min.; interior
skin 27 ga.
HDP20, HDPF20, HDPL20, 7200, 7201, min.) Single -Car (up to 9'0" wide) WINDCODE® W6 Garage
Door
7203, 8200, 8201, 8203
.......................................................................................................................................................'..........................................................................................................................................................................................
.
Limits of Use !Installation Instructions
Approved for use in HVHZ: No i FL16107 R14 IT 104184-B-R v05 Rdf
Approved for use outside HVHZ: Yes ! Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF ! Evaluation Reports
Other: Doors with standard glazing meet the wind load requirements of ? FL16107 R14 AF Cl3PC 140 0-A odf
the building code but DO NOT meet the impact resistant requirement for Created by Independent Third Party: No
windborne debris regions.
....................... ....................... .................... ..................... ............... ;...........................................................................................................................................
16107.43 .43 W6-16 DSIU-1F171: 9200, 9201, 9203, Double -skin Insulated PUR (exterior skin 27 ga. min.; interior
skin 27 ga.
HDP20, HDPF20, HDPL20, 7200, 7201, min.) Double -Car (9'2" to 167' wide) WINDCODEQ W6 Garage
Door with
7203, 8200, 8201, 8203 Optional Impact -Resistant Lites
Limits of Use ! Installation Instructions
Approved for use in HVHZ: Yesi F t6107 R14 IT 10487 -A-R 05 odf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF ;Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with FL16107 R14 AE CBPC 140220-A p�Jf
! optional impact -resistant glazing are impact -resistant (large missile Created by Independent Third Party: No
impact).
..................... ...................... .................... ......................... .............. ............................................................................................................................................................ .................................................................................................................................................................................................
......................................... ........
......... .......
16107.44 44 W6-16 DSIU-11`171: 9200, 9201, 9203, ! Double -skin Insulated PUR (exterior skin 27 ga. min.; interior
skin 27 ga.
HDP20, HDPF20, HDPL20, 7200, 7201, min.) Double -Car (9'2" to 167' wide) WINDCODE@ W6 Garage
Door
i 7203, 8200, 8201, 8203
Limas of Use ! Installation Instructions
Approved for use in HVHZ: No FL16107 R14 II 104879-B-Rev05 pdf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF i Evaluation Reports
Other: Doors with standard glazing meet the wind load requirements of EL16707 R14 AE CBPC140 0-A p�
,the building code but DO NOT meet the impact resistant requirement for Created by Independent Third Party: No
windborne debris regions.
.............................................................................................................................................................................................................................................
16107.45 45 W3-09 DSIU-1A171: 9130, 9131, 9133, ! Double -skin Insulated PUR (exterior skin 27 ga. min.; inte
for skin 27 ga.
HDP13, HDPF13, HDPL13, 7130, 7131, min.) Single -Car (up to 9'0" wide) WINDCODE(V W3 Garage
Door
i.7133, 8130, 8131, 8133 i
.............................
Limits of Use !Installation Instructions
Approved for use in HVHZ: No i F 1 6y 07 R14 II t 04t 7 -R v04 p�{
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +20 PSF/-21 PSF Evaluation Reports
Other: The OPTIONAL glazing available for this product meets the wind ! Fl 16107 R14 AF CRPC140 0-A,odf
load requirements of the building code but DOES NOT meet the impact Created by Independent Third Party: No
resistant requirement for windborne debris regions. The product without
glazing DOES comply with the impact resistant requirement for
windborne debris regions (ref 1609.1.2 FBC).
t....... .... .............. ................................. ............................... ................................ .................................. ........................... .................................... ......... ............................... ......................................... ............................................................ !....
16107.46 i 46 W7-09 PAN-21`153: 73, 75, 84A, 94, 98, ! Steel Pan (min. 25 ga.) Single Car (up to 9'0" wide) WINDCODE®
.... ...................................... ........
W7
42, 42B, 48, 48B, 4F, 4RST, 6RST,GD5S, Garage Door with Optional Impact -Resistant Lites
GD5SV, GRSS, GRSSV, AR5S, AR5SV, ED5S, !
EDSSV
...................................................................................................:.......................................................................................................................................................................................................
.............................................................................................................................................................._.....................................................
Limits of Use ! Installation Instructions
Approved for use in HVHZ: Yes ; FL16107 R14 II 101702-Rev13 pd
Approved for use outside HVHZ: Yes ! Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes Created by Independent Third Party: No
Design Pressure: +42 PSF/-48 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with ; FL16107 R14 AF CBPC140625-n p�f
optional impact -resistant glazing are impact -resistant (large missile i Created by Independent Third Party: No
impact).
..................................................
16107.47 47 W5-16 PANSP-2F153/6: 73SP, 15SP, Steel Pan (min. 25 ga.) Double -Car (92" to 16'0" wide) WINDCODE@
INS
765P, 76VSP, GD5SSP, GD5SPV !Garage Door with Optional Impact -Resistant Lites
-- - - - - - -
-----------------------------
Limits of use !Installation Instructions
Approved for use in HVHZ: No i FL16107 R14 II 104818-A-R v03 odf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes Created by Independent Third Party: No
Design Pressure: +32 PSF/-37 PSF Evaluation Reports
Other: Solid doors (no glazing) or doors with optional impact -resistant FL16107 R14 AF CBPC1406;15-n_
glazing are impact -resistant (large missile impact). Created by Independent Third Party: No
.......................................................................................................................................................................
16107.48 48 W5-16 PANSP-21`153/6: 73SP, 15SP, Steel Pan (min. 25 ga.) Double -Car (92" to 16'0" wide) WINDCODE@
W5
76SP, 76VSP, GD5SSP, GD5SPV ;Garage Door
Limits of Use i Installation Instructions
Approved for use in HVHZ: No FL16107 R14 II 104818-B-R v03.p lJff
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No i Created by Independent Third Party: No
Design Pressure: +32 PSF/-37 PSF ' Evaluation Reports
Other: Doors with standard glazing meet the wind load requirements of FL16107 R14 AE CBPC 140 2n-A_p
the building code but DO NOT meet the impact resistant requirement for Created by Independent Third Party: No
windborne debris regions.
-------------------- ------....----------------------------------------------------......---------:_....--------------------------------------------------------------------------------------.._.._---
16107.49 49 W8-09 W-1G899: Custom Reserve Custom Wood Single -Car (up to 9'0" wide) WINDCODE®
W8 Garage Door
' Collection CR800, MR800, CH800, CRDnnn
............. ........... ..... ....... ....... .......... ........................ ......................... :...........................................................................................................................................................
.......................................................................................................................................................... ... ... .........................................
Limits of Use Installation Instructions
...................... ..................................
Approved for use in HVHZ: Yes ! FL16107 R14 II 10493 -R v03 pdf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes Created by Independent Third Party: No
Design Pressure: +47 PSF/-55 PSF ;Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with i FL16107 R14 AE CBPC 121212-A p l�f
optional impact -resistant glazing are impact -resistant (large missile Created by Independent Third Party: No
impact).
.
..........................................................................................................................
16107.50 50 W7-16 W-1G899: Custom Reserve i Custom Wood Double -Car (9'2" up to 167' wide) WINDCODE®
W7
Collection CR800, MR800, CH800, CRDnnn Garage Door
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes ! F 16107 R14 II 104 qR-aP, n pd
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes Created by Independent Third Party: No
Design Pressure: +41 PSF/-48 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with i FL16107 R14 AE CBPC 1 1 1 -A pdf
optional impact -resistant glazing are impact -resistant (large missile Created by Independent Third Party: No
impact).
.............................................................................................................
16107.51 51 W6-16 SPO-2F449: Grand Harbor, !Steel Pan (min. 24 ga.) with Overlay Double -Car (9'2" to
16'2" wide)
Evanston, Stone Manor ! WINDCODE® W6 Garage Door
.............................................................................................................................................................................................................................................................................................................................................
.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R14 II 104790-A-RevO9.pdf
Approved for use outside HVHZ: Yes i Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact- FL16107 R14 AE CBPC 1304 -A pdf
resistant (large missile impact).i Created by Independent Third Party: No
-- --------------------
-------------------------
16107.52 52 W6-16 SPO-21`499: Grand Harbor, iSteel Pan (min. 24 ga.) with Overlay Double -Car (9'2" to
167' wide)
Evanston, Stone Manor WINDCODEO W6 Garage Door
Limits of Use Installation Instructions
Approved for use in HVHZ: No ! FL16107 R14 II 104790-B-Rev09 p Id
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: N/A Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load requirements of i FL16107 R14 AE CBPC 130423-A odf
the building code but DO NOT meet the impact resistant requirement for Created by Independent Third Party: No
windborne debris regions.
Go to Page
Page 3/3
4Tacls next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund
Statement
do not send
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request,
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.
395. *Pursuant
to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email
address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are publ
s record. If you
do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public
To determine if
you are a licensee under Chapter 455, F.S., please click here_
Product Approval Accepts:
CrtiE Card
.................
..............................