Loading...
HomeMy WebLinkAbout20-0722.16 CGI SERIES 160 SENTINEL AMUMINUM OUTSWING GLAZED DOOR WITH OR WITHOUT SL'S NOA No. 20-0722.16 Expiration Date: August 08, 2023 Approval Date: November 05, 2020 Page 1 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy CGI Windows & Doors, Inc. 3780 W. 103rd Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series “160 Sentinel” Aluminum Outswing Glazed Doors w/wo Sidelites - LMI APPROVAL DOCUMENT: Drawing No. MD-160FD Rev A (former W13-01 Rev F), titled “Series Sentinel 160 Alum Outswing Door”, sheets 1 thru of 14 of 14, , prepared by manufacture, dated 07/14/20, signed and sealed by Lynn A. Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance numbe and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Limitations: 1. See Design Pressure ratings single and double doors in sheet 3, single sidelite in sheet 4 and door mullion in sheet 5. For mulled unit lower design of door or sidelite or mullion shall apply to the entire assembly. 2. See glazing option in sheets 1 and 2 and locking hardware options in sheet 10. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami-Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises # 17-1222.16 and consists of this page 1 and evidence pages E-1, E-2, E-3 & E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No 20-0722.16 Expiration Date: August 08, 2023 Approval Date: November 05, 2020 E - 1 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’S A. DRAWINGS 1. Manufacturer's die drawings and sections (submitted under files below) 2. Drawing No.W13-01 Rev D, titled “Series 160 Sentinel Outswing Doors”, sheets 1 thru of 11 of 11, inclusive sheet 9.1, prepared by Al-Farooq Corporation, dated 01-03-13 and last revised on AUG 05, 2015, signed and sealed by Javad Ahmad, P.E. B. TESTS (submitted under file #13-0226.06) 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94(+50.0 PSF, sill S-I only) 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 Along with manufacturer’s parts and section drawing marked-up drawings of aluminum out w/ sidelites, by American test Lab of South Florida, Inc., Test Report No. ATLSF-1218.01-12 dated 02/11/2013, signed and sealed by Henry Hatem, P.E. 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with manufacturer’s parts and section drawing marked-up drawings of aluminum sidelites, issued by Certified Testing Lab., Test Report No. CTLA 3056WC (sample #3) dated 04/16/2015, signed and sealed by Ramesh Patel, P.E C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2014 (5th Edition), prepared by Al Farooq Corporation, dated 10/06/2014, 05/19/15 and last revised on AUG 04, 2015, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies w/ ASTME-1300-02, -04 and -2009. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0624.02 issued to E.I. DuPont DeNemours & Co., Inc. for their “DuPont Sentry Glass ® Interlayer”, expiring on 01/14/17. 2. Notice of Acceptance No. 12-1231.10 issued to Eastman Chemical Company (MA) former Solutia Inc. for “Saflex clear & color glass interlayer “, expiring on 05/21/16. 3. Notice of Acceptance No. 12-1231.08 issued to Eastman Chemical Company (MA) former Solutia Inc. for “Saflex CP-Saflex & Saflex HP composite interlayer w/ PET core “, expiring on 12/11/18. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No 20-0722.16 Expiration Date: August 08, 2023 Approval Date: November 05, 2020 E - 2 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to FBC 2014 (5th Edition) and letter of no financial interest, prepared by Al Farooq Corporation, dated 09/23/14, signed and sealed by Javad Ahmad, P.E. 2. Lab compliance and addendum letters, as part of the above referenced test reports. G. OTHER 1. This file NOA revises # 13-0226.06, expiring 08/08/18. 2. Test proposals approved dated 12/16/14 & # 12-0553, dated 04/25/12 approved by RER. 2. EVIDENCE SUBMITTED UNDER PREVIOUS NOA(s) A. DRAWINGS 1. Drawing No.W13-01 Rev F, titled “Series Sentinel 160 Alum Outswing Door (L.M.I./S.M.I.)”, sheets 1 thru of 13 of 13, inclusive sheet 1.1, prepared by Al-Farooq Corporation, dated 01/03/13 and last revised on 02/13/18, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with manufacturer’s parts and section drawing marked-up drawings of aluminum out w/ sidelites, by Fenestration Testing Laboratory, Inc., Test Report No. FTL 17102 dated 05/19/17, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6th Edition (2017), prepared by Al Farooq Corporation, dated 11/13/17, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies w/ ASTME-1300-09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America., Inc. for their “Sentry Glas® (Clear and White) Interlayer”, expiring on 07/04/23. 2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their “Saflex Clear & Color glass Interlayers “, expiring on 05/21/21. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No 20-0722.16 Expiration Date: August 08, 2023 Approval Date: November 05, 2020 E - 3 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS (continue) 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their “Saflex CP-Saflex & Saflex HP Composite Glass Interlayers w/ PET Core “, expiring on 12/11/18. 4. Notice of Acceptance No. 17-1114.14 issued to Kuraray America., Inc. for their “Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayers”, expiring on 07/08/19. F. STATEMENTS 1. Statement letter of conformance to FBC 6th Edition (2017) and of no financial interest prepared by Al Farooq Corporation, dated 11/13/17, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. This NOA revises NOA #14-1015.04, expiring on 08/08/18. 2. Test proposal #16-0947, dated 07/26/16, approved by RER. 3. New Evidence submitted A. DRAWINGS 1. Drawing No. MD-160FD Rev A (former W13-01 Rev F), titled “Series Sentinel 160 Alum Outswing Door”, sheets 1 thru of 14 of 14, , prepared by manufacture, dated 07/14/20, signed and sealed by Lynn A. Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202–94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202–94 3) Water Resistance Test, per FBC, TAS 202–94 4) Large Missile Impact Test per FBC, TAS 201–94 5) Cyclic Wind Pressure Loading per FBC, TAS 203–94 along with marked-up drawings and installation diagram of all CGI Windows and Doors, Inc. and PGT Industries, Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No 20-0722.16 Expiration Date: August 08, 2023 Approval Date: November 05, 2020 E - 4 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (continue): PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 2020, 7th Edition, prepared by manufacturer, dated 07/14/20, signed and sealed by A. Lynn Miller, P. E. 2. Glazing complies with ASTM E1300–04, -09, -12 and-16. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. (former E.I. DuPont DE Nemours & Co., Inc.) for the “Sentry Glass ® Interlayer”, expiring on 07/4/23. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. (Former E.I. DuPont DE Nemours & Co., Inc. for the “Kuraray Trofosil Ultra clear and color PVB Interlayer (Former Kuraray Butacite ® PVB interlayer)”, expiring on 07/08/24. 3. Notice of Acceptance No. 18–0301.06 issued to Eastman Chemical Company (MA) (Former Solutia, Inc.) for the “Saflex CP - Saflex and Saflex HP Composite Glass Interlayers w/ PET Core”, expiring on 12/11/23. F. STATEMENTS 1. Statement letter of conformance to FBC 2020 (7th Edition), issued by manufacturer, dated 07/14/20, signed and sealed by Lynn Miller, P. E. 2. Notification of Successor Engineer per the Florida Administrative Code Section 61G15-27.001, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated 07/20/20, signed and sealed by A. Lynn Miller, P.E. G. OTHER 1. This NOA revises 17-0227.05 expiring 08/08/23 for FBC 2020 updates. 2. RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda, P.E.