Loading...
HomeMy WebLinkAboutTruss® Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. MiTek® RE: 27052 - Gingras Residence MITek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: Mel-Ry Construction Project Name: Gingras Residence Model: Customa'•F s ory0�115 Lot/Block: 833 Subdivision: Venture 2 Address: lot 833 Stingray City: Port St. Lucie State: Florida Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria $ Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): -'Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.5 Wind Code: ASCE 7-10 [All Heighll Wind Speed: 170 mph Roof Load: 47.0 psf Floor Load: 55.0 psf This package includes 57 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. 1 Seal# I Truss Name I Date I No. I Seal# Truss Name I Date 1 IT6375406 IA01G 6/19/014 118 IT6375423 -CJ3 6/19/014 12 I T6375407 I A02 16/19/014 119 I T6375424 I -CJ3B 16/19/014 1 13 I T6375408 I A03 16/19/014 1 20 I T6375425 I -CJ4 16/19/014 1 14 I T6375409 I A04 16/19/014 121 I T6375426 I -CJ5 16/19/014 1 15 I T6375410 I A05 16/19/014 122 I T6375427 I -CJ5B 16/19/014 1 16 I T6375411 I A06 16/19/014 123 I T6375428 I D01 G 16/19/014 1 17 I T6375412 I A07 16/19/014 124 I T6375429 1 D02 16/19/014 I 18 I T6375413 I A08G 16/19/014 125 I T6375430 I D03 16/19/014 1 19 I T6375414 I B01 G 16/19/014 126 I T6375431 I D04 16/19/014 1 110 I T6375415 I B02 16/19/014 127 I T6375432 I -EJ 1 C 16/19/014 1 111 I T6375416 1 B03 16/19/014 128 I T6375433 1-EJ2 16/19/014 1 112 J T6375417 I B04 16/19/014 129 I T6375434 1-EJ2C 16/19/014 1 113 I T6375418 I C01 G 16/19/014 130 I T6375435 I -EJ3 16/19/014 1 114 I T6375419 I CO2 16/19/014 131 I T6375436 I -EJ3C 16/19/014 1 115 I T6375420 I -CJ1 16/19/014 132 I T6375437 I -EJ4C 16/19/014 1 116 I T6375421 I -CJ 1 B 16/19/014 133 I T6375438 I -EJ5 16/19/014 1 117 I T6375422 I -CJ2 16/19/014 134 I T6375439 I -EJ5C 16/19/014 1 The truss drawing(s) referenced above have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by East Coast Truss. Truss Design Engineer's Name: Albani, Thomas My license renewal date for the state of Florida is February 28, 2015 IMPORTANT NOTE: Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2D A. q 14' 0 39380 j ATE ' �: FL Cert. 6634 :] June 19,2014 Albani, Thomas 1 of 2 RE: 27052 - Gingras Residence Site Information: Customer Info: Mel-Ry Construction Project Name: Gingras Residence Model: Custom 2 story Lot/Block: 833 Subdivision: Venture Address: lot 833 Stingray City: Port St. Lucie State: Florida No. Seal# Truss Name I Date 35 IT6375440 -EJ6C 6/19/014 136 IT6375441 I -EJ7 16/19/014 137 IT6375442 I -ERC 16/19/014 1 138 IT6375443 I-EJ8C 16/19/014 1 139 IT6375444 I-EAC 16/19/014I 140 IT6375445 I FG01 16/19/014 I 141 IT6375446 I FG02 16/19/014 142 IT6375447 I FG03 16/19/014 143 IT6375448 I FG04 16/19/014 144 IT6375449 I FL01 16/19/014 I 145 IT6375450 I FL02 16/19/014 I 146 IT6375451 I FL03 16/19/014 I 147 IT6375452 I FL04 16/19/014 I 148 IT6375453 I FL05 16/19/014 I 149 I T6376454 I -HJ 1 16/19/014 150 I T6375455 I -HJ3 16/19/014 I 151 IT6375456 I -HJ3D 16/19/014 I I52 IT6375457 I -HJ5 16/19/014 I �53 IT6375458 I-HJ513 16/19/014I 54 I T6375459 I -HJ7 16/19/014 1 155 IT6375460 I-HJ7A 16/19/014I 156 IT6375461 I MG01 16/19/014 I 157 IT6375462 I MV3 16/19/014 I 2 of 2 Job Truss Truss Type Qty Ply Gingras Residence T6375406 2705:1 A01G Roof Special Girder 1 1 Job Reference (opt oal East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:1329 2014 Vage 1 I D:p?QmlfchP88mXvBBT2NUhcz4kwS-k?vioN?OkyjQHtDCfncgD6p6111 cLFErOccvgQz4jd4 7-0-0 1as 4 14-0-9 15-1-8 18-7-0 23-1-8 _ 7-0-0 114. 3-6.4 1-0-15 3.5.8 4-6-8 Scale = 1:39.9 2.79 12 NAILED • 3.00 12 4x8 = NAILED 3x8 4x6 4x4 3x4 = NAILED 5x8 M18SHS = 3x4 = 3x8 = 1x4 11 3x8 = Special HUS26 1-ao 1 a• 7-ao 1as-a 14-0-s 1st-e 18- -0 23-1-8 1.0.0 0.4• 5.8.0 3-s-4 3-6-4 1-a15 3-5.8 4-8-8 Plate Offsets (X Y)-- 11:0-7-4 0-1-121 LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr NO Code FBC201 0/TP 12007 CSI. TC 0.98 BC 0.88 WB 0.73 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 *Except* 1-2: 2x4 SP 2856F 1.8E BOT CHORD 2x4 SP 285OF 1.8E 'Except' 1-11: 2x6 SP SS WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=2172/0-8-0, 7=1615/0-8-0 Max Horz 1=-56(LC 6) Max Uplift 1 =-609(LC 4), 7=-424(LC 5) DEFL. in floc) I/deft Ud PLATES GRIP Vert(LL) 0.35 10-11 >791 240 MT20 244/190 Vert(TL)-0.8710-11 >319 180 M18SHS 244/190 Horz(TL) 0.15 7 n/a n/a Weight: 107 lb FT = 0% BRACING - TOP CHORD • Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-10-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-1860/488, 1-2=-5788/1640, 2-20=-5638/1627, 3-20=5638/1627, 3-4=-5651/1505, 4-5=-4707/1264,5-6=-4754/1264,6-7=-4824/1268 BOT CHORD 1 -1 =-436/1551, 1-12--1532/5549, 12-21 =-1 842/6973, 21-22=-1842/6972, 11-22=-1835/6947, 10-11=-1821/6893, 9-10=-1412/5605, 8-9=-1185/4631, 7-8=-1185/4631 WEBS 2-12=-230/1035, 3-12=-1493/348, 3-11=-249/962, 3-1 0=-1 513/562, 4-10=-223/617, 4-9=-1945/520, 5-9=-483/1910, 6-9=459/394 . NOTES- 1) Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl„ GCpl=0;18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.6 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated, 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) • This truss has been designed for a live load of 20,Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=609, 7=424. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 10) Use Simpson Strong -Tie HUS26 (14-1 Od Girder, 4-10d Truss, Single Ply Girder) or equivalent at 9-11-0 from the.left end to connect truss(es) to back face of bottom chord. 11) Fill all nail holes where hanger is In contact with lumber. 12) "NAILED" indicates 3-1 Od (0.148"4") or 3-12d (0.148" 0.25") toe -nails. For more details refer to MITews ST-TOENAIL Detail. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 437 lb down and 180 lb up at 7-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (3). %% A. � O• S•. .9 i 39380 --� ' lATE wZ. I ,441 A'� o R , o 1s , .5'ONA` 1����, FL Cert. 6634 June 19,2014 Continued on roe 2 ® WARWAG, •Vedfi design parameters'-d READ A07ESGM179SAW IhaUDED HITEKREFEREACERAGEM11-7473 ma I/29/2014DfFMEX& Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the MY� MAW erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication. quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inlormallon va' able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. 1f5outhernRine7SP lumberisspecified,thedefignvaluesarethose ffective0fi O3J20131iyA1SC Tampa, FL 33610-4115 Job Truss Truss Type Qty Gingras Residence T6375406 27052 r • A01G Roof Speclal Girder ]Ply 1 1 Job Reference o t'o al East Coast Truss, Fort Pierce, FL. 34946 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-74, 2-4=-74, 4-5=-74, 5-7=-74, 1-17=-20 Concentrated Loads (lb) Vert: 2=-99(8) 12=-437(B) 20=-99(B) 21=29(1]1) 22=-947(6) 7.520 a Apr.222014 MITeK Industries,, Inc. -I nu Jun lY 13:1J:2Y 2V14 vage z ID:p?Qm IfchP66mXvB BT2N Uhcz4kwS-k?vioN?OkyjQHlDCfncgD6p6l11 cLFErOccvgQz4jd4 ®WA MM -Versfy *Wp parameoers aad NrAD AWESGIV ROSAW INCLUDED M114423 Ma r/29J2016aE aMME Design valid for use only with Mirek connectors. This design is based only upon parameters shown, and is for an individual building component. �• Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsiblllity, of the MITP.k• erector. Additional permanenfbracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Salety Informatign va able from Truss Plate Institute. 781 14. Lee Street, Suite 312, Alexandria, VA zp2314. If 3o utheIM PIne�SP� lumber is specili ed, the design values are thrbse effective 06/0112013 by ALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375407 27052 A02 Hip 1 1 Job Reference factional East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 Walk Industries, Inc. Thu Jun 19 13:13:30 2014 Page 1 I D: p7Qm IfchP88mXvBBT2NUhcz4kwS-CCT4DjOeVGsHu1 nODV7vmKMOzRNz4gi7EGLSCsz4jd3 5-0-B 9-0-0 14-1-8 1e-1-0 23-1-8 , 5-0.8 3-11.8 5-1.8 3.11-8 5-0-8 Scale = 1:39.2 4x8 = 3.00 12 44 = 3x4 = 3x8 11 3x4 = 3x4 = 3x8 = 3x8 = 1-0-0 0-4- 7.8.0 5.1.8 9-0-0 Plate Offsets (X,Y)-- (1:0-0-0.1-8-131 i1:0-4-8 0-0-21 (3:0-5.4 0-2-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL - 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) 0.16 7-9 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.87 Vert(TL) -0.47 7-12 >585 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.20 Horz(TL) 0.10 6 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 98 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-1-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-4-11 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing WEDGE be installed during truss erection, in accordance with Stabilizer Left: 2x4 SP No.3 Installatione REACTIONS. (lb/size) 6=1058/0-8-0, 1=1115/0-8-0 Max Horz 1=64(LC 7) Max Uplift6=-240(LC 5), 1=-254(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-996/217, 1-2=-2637/610, 2-3=-2380/490, 3-4=-2373/510, 4-5=-2458/507, 5-6=-2964/708 BOT CHORD 1-13=-207/926, 1-9=-547/2513, 8-9=-394/2297, 7-8=-394/2297, 6-7=-641/2837 WEBS 2-9=-273/160, 4-7=-19/303, 5-7=514/253 NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 ,♦♦� S plate grip DOL=1.60 ♦ P q 3) Provide adequate drainage to prevent water ponding. ��♦♦ Q�• • \ G•E•NS�� ' • 4) Plates checked for a plus or minus 0 degree rotation about its center. ,,��`�`.•'�,� •,9!j 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. '. 6) • This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will PQ'6 3938 _=4� fit between the bottom chord and any other members. * �� 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 6=240, 1=254. Mir 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ATE '•411 i�� s . 10�, 61ONA1-E� ,% �rrr►nIIII � FL Cert. 6634 June 19,2014 AWARNIM•Vedfrdesign paracrem and RCAF AMESCH7MS AND INCLUDED MITEKREFEREMX PAGE MII.7473 m. I1291201dafFMME ■ Design valid for use onN with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responslblllity of the WOWerector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va• able from Jruss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. It SouthernP'ine�SP lumberisspecified,thedesignvaluesarethoseetfective06 01/2013ibyAL5C Tampa, FL 3361GAI lS Job Truss Truss Type Qty Ply Gingras Residence T6375408 27052V A03 Hip 1 1 Job Reference factional) East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITeK Industnes, Inc. Thu Jun 19 1 3:1J:31 ZU14 rage 1 ID:p9QmlfchPBBmXvBBT2NUhcz4kwS-g01SD21GGa 8WBManCeBIXvZ6rj4pDIBTv5Cklz4jd2 6-0-8 11-0-0 12-1-8 17-1-0 23-1-8 6-0-8 4-11-8 1-1-8 4-11.8 6-0-8 Scale = 1:39.2 4x8 = 4x4 = 3.00 12 3x4 = 3x8 I 1x4 I 3x4 = 5x8 = 1x4 II US - 1.0-0 1 4- 6-0-8 11-0-0 12-1-8 17-1-0 23-1-8 1-0.00-4- 4-8-8 4-11-8 1-1-8 . 4-11-8 8-0.8 Plate Offsets (X Y)-- 11.0-0-0 1-8-131 f1.0-4-8 0-0-21 13.0-5-8 0-2-01 18.0-4-0 0-3-01 LOADING•(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.52 Vert(LL) 0.17 7-8 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.88 Vert(TL) -0.46 7-8 >608 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.47 Horz(TL) 0.11 6 n/a n/a BCDL 10.0 Code FB C201 0/TP 12007 (Matrix-M) Weight: 101 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 6=105810-8-0, 1=111510-8-0 Max Horz 1=78(LC 7) Max Uplift6=-267(LC 5), 1=-280(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-1004/250, 1-2=2652/668, 2-3=-2114/525, 3-4=-2024/534, 4-5=-2120/529, 5-6=-2933/733 BOT CHORD 1-14=-232/925, 1-10=-603/2532, 9-10=-603/2532, 8-9=-409/2022, 7-8=-657/2801, 6-7=-657/2801 WEBS 2-9=-606/205, 3-9=-49/275, 4-8=-63/313, 5-8=-856/273 Structural wood sheathing directly applied or 3-2-0 oc purlins. Rigid ceiling directly applied or 7-3-8 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide NOTES- 1) Unbalanced roof live loads have been considered for this design. `ot,1111111111, 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; ,**% 5' A. ��� Exp D; Encl., GCpl=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 ,�% P. plate grip DOL=1.60 e4 o'' GCE N S'• 3) Provide adequate drainage to prevent water ponding. ,,�,``r,• �,��'..�, 4) Plates checked for a plus or minus 0 degree rotation about its center. -- " •� 3 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 39380.. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in ail areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 6=267, _ � a: 1=280. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. �O AT E : ��: .,0,;/ /ONA`,` nnnl FL Cert. 6634 ::] June 19,2014 A WARN M•Verifydeslita pmalmD!rs,gad RFAD AV77..5Gff 7WISAWD M&DEDt47TFXRFFERENt'ZMGFK11-742:1am 1jM120tdNE7'0fftnF Design valid for use only with Wek connectors. This design is based only upon parameters shown, and is for an individual building component. ■■ �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibilllty of the MITek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety I format on 4vprble from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. 1f50uttertl i1tiiSP1lumtt.riss,.,1iiie+d,thedesign values firethese effective46�0212013by74t.5£ Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375409 270521 A04 Common 1 1 Job Reference o tiOnai East Coast Truss, Fort Pierce, FL. 34945 6-3.14 3.00 F12 5-2-14 44 = 7.S2u s Apr Z2 ZU14 MI I eK mousines, mc. I nu Jun lu 1:1:1J:J7 Lu14 cage I ID:p7QmlfchP88mXvB BT2NUhcz4kwS-gO1 SD21 GGa—BWBManCeBlXvXrrkapGj8Tv5Oklz4jd2 5-2-14 3x8 11 3x4 = 3x4 = 3x4 = 6-3-14 Scale=1:38.5 3x4 = 3x8 = 1.0.0 1 4 8.2-13 15-1-11 23-1-8 1-0.0 0-4- 5.10.13 6-10-13 7-11-13 Plate Offsets (X Y)— 11:0-4-8 0-0-21,11:0-0-0.1-8-131 LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft Lld PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.66 Vert(LL) 0.19 6-8 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.78 Vert(TL) -0.53 6-8 >527 180 BCLL 0.0 Rep Stress Incr YES WB 0.28 Horz(TL) ' 0.10 5 n/a nla BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 92 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 5=105810-8-0, 1=1116/0-8-0 Max Horz 1=81(LC 7) Max Uplift5=-274(LC 5), 1=-289(LC 4) BRACING - TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-0-10 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection; in accordance with Stabilizer Installation gu FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 1-1=-1001/259, 1-2=-2686/722, 2-3=-2385/623,3-4=-2574/680, 4-5=-2931/784 BOT CHORD. 1-12=-2441929, 1-8=-653/2563, 7-8=-420/1899, 6-7=-420/1899, 5-6=-705/2799 WEBS 2-8=-406/194, 3-8=-105/537, 3-6=-167/735, 4-6=-484/223 NOTES- 1)'Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) The solid section of the plate is required to be placed over the splice line at joint(s) 7. �0 •'•. 4) Plate(s) at joint(s) 5, 8, 2, 3, 6, 4, 1 and 1 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 7 checked for a or minus 5 degree rotation about its center. ,♦ 0 G � N � �<J plus 6) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. ♦♦ l yam' ♦•�•• • ♦ 3, 7) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will • 39380 fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=274, o + 1=289. �AT 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. PO�O•• E : Z. �44/ • o,�SS < p R O P •�N % ���, N A� E�.�. /0 FL Cert. 6634 June 19,2014 ®WARNIM-Vedfrdesign pan,metiers aad RFAD ACUSON MISAW IMVDCD MMKREFEREMTFACFM77.7473 m. 2/29/2D[QDFFOUME Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown p Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the iVliTek• erector. Additional permanent bracing of the overall structureJs the responsibility of the bullding designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inlorma Ion va ble from Truss Plqte In titute, 781 N. Lee Street, Suite 312, Alexandria, VA Z2314. Tampa, FL 33610-4115 If Southe.tn irte�SPumber iss"cilie , the deMgn values are these effective 45 01121013 by ALSC 4 Job Truss Truss Type Qty Ply Gingras Residence T6375410 2705:r ' A05 Attic 2 1 Job Refere ce o do a East Coast Truss, Fort Pierce, FL, 34946 7.520 s Apr 22 2014 MTek Industries, Inc. Thu Jun 19 13:13:32 2014 Page 1 ID:p7QmlfchP88mXvBBT2NUhcz4kwS-8abfRO1 u11678LxnLv9NrlRgoE57YjOHiZgZHlz4jdl i 7-5-0 11-0-0 12-1-8 16-8.8 23-1-8 i 7-5-0 3-7-0 1-1-8 3-7.0 7-5-0 3x4 = 3x4 = 3.00 12 Scale = 1:39.9 3x6 = 5x5 = 5x5 = 3x6 = LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Cade FBC2010/TPI2007 CSI. TC 0.78 BC 0.76 WB 0.32 (Matrix-M) DEFL. in Vert(LL) -0.42 Vert(TL) -0.82 Horz(TL) 0.09 Attic -0.18 (loc) I/deft Ud 9-10 >660 240 9-10 >340 180 8 n/a n/a 9-10 542 360 PLATES GRIP MT20 244/190 Weight: 89 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP 285OF 1.8E `Except TOP CHORD Structural wood sheathing directly applied or 3-0-12 oc purlins, 4-5: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 9-5-14 oc bracing. BOT CHORD 2x4 SP No.1 *Except* MiTek recommends that Stabilizers and required cross bracing 9-10: 2x6 SP SS, 3-6: 2x4 SP No.2 be Installed during truss erection, in accordance with Stabilizer WEBS 2x4 SP No.3 Installatione WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 8=1100/0-8-0, 1=1156/0-8-0 Max Horz 1=78(LC 7) Max Uplift8=-243(LC 5), 1=-251(LC 4) Max Grav 8=1369(LC 15), 1=1448(LC 14) FORCES, (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-1449/217, 1-2=-3668/502, 2-3=-3524/522, 3-4=-612/735, 4-5=-457/40, 5-6=-453/1217, 6-7=-3507/528, 7-8=-3670/729 BOT CHORD 1-14=-202/1342, 1 -1 0=-429/3482, 9-10=-426/3512, 8-9=-731/3530 WEBS 2-10=01464, 7-9=0/468, 3-24=-2073/425, 6-19=-3061/511, 6-21=-2858/498 ,�Illlllf►!II NOTES- A. 1) Unbalanced roof live loads have been considered for this design. �� P 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; �� 0 Exp D; Encl., GCpl=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 ��;��•••�\ C' E N S� e9if!` plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 0 39380 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will - {z ► fit between the bottom chord and any other members. : ,' SAT E 7) Ceiling dead load (5.0 psf) on member(s). 2-3, 3-20, 4-20, 4-5, 5-23, 6-23, 6-7 8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (0.0 psf) applied only to room. 9-10, 19-21, 21-24, 22-24 j0 AN 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except Gt=lb) 8=243, �j� • .. R >, \ �� 1=251. 4#� s ....•• \CI �� 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. -* S�� AL 11) Attic room checked for U360 deflection. �4�I j I111"' FL Cert. 6634 —] June 19,2014 ® WARNIAG N1WV d W9. panmco=rs and RE4D WES0MMMAND 1=11DED METFKR£FEREMTPAGEMU 74Y3 n:.. Tjd.9j20I48HOREME Design valid for use only with M7ek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown . Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Intormatlon 7vailIable from.Jruss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA $2314 115outhcln the SPklumtrerissue>;11ed>thedeslgnvaiuesaTethiaof#ettiva051a2ZIO13byAtSC Tampa, FL 33610-4115 Job. Truss Truss Type Qty Ply Gingras Residence T6375411 270520 A06 Attic 5 1 Job Re ere ce o tional East Coast Truss, Fort Pierce, FL. 34946 11-10-0 11.6-12 -- 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:33 2014 Page 1 ID:p?Qm IfchP8BmXvBBT2N Uhcz4kwS=dm8Dek2 WnB EsNWzudgcNy_p5eNiH90RwDa6pBz4jdO 7-5-0 3-2-9 0-7-15' 0'3.4 3-2-9 7-5-0 Scale = 1:39.2 0-3-4 0.7-15 I 7-6-12 i ADO= 7-6-12 3.00 12 3x8 = 5x5 = 5x5 = 3x8 = LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2010/TPI2007 CSI. TC 0.93 BC 1.00 WB 0.33 (Matrix-M) DEFL. In Vert(LL) -0.48 Vert(TL) -0.96 Horz(TL) 0.10 Attic -0.18 (loc) I/defl Ud 8-9 >583 240 8-9 >290 180 7 n/a n/a 8-9 536 360 PLATES GRIP MT20 244/190 Weight: 88 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP 285OF 1.8E TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. 8-9: 2x6 SP SS MiTek recommends that Stabilizers and required cross bracing WEBS 2x4 SP No.3 be installed during truss erection, in accordance with Stabilizer WEDGE Left: 2x4 SP No.3 Installation REACTIONS. (lb/size) 7=1106/0-8-0, 1=1150/0-8-0 Max Horz 1=-81(LC 6) Max Uplift7=-251(LC 5), 1=-257(LC 4) Max Grav7=1345(LC 15), 1=1406(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-1407/228, 1-2=-3466/514, 2-3=-3320/537, 3-4=-348/1071, 4-5=-264/15l 1, 5-6=-3308/544,6-7=-3808/798 BOT CHORD 1-13=-201/1238, 1-9=-441/3281, B-9=-438/3312, 7-8=-753/3566 WEBS 2-9=0/471, 6-8=0/465, 3-23=-2450/475, 5-18=-3375/573, 5-20=-3041/525 NOTES- ,tt1/11111111'r 1) Unbalanced roof live loads have been considered for this design. � S A. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; �� P` Iq Exp D; Encl., GCpl=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left -and right exposed; Lumber DOL=1.60 ♦♦ Q0• • • ..... • - plate grip DOL=1.60 ♦♦ G E N g • • q� �� 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 0 3938 5) • This truss has been designed for a live load of 20.Opsf an the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will * �.- fit between the bottom chord and any other members. �- 6) Ceiling dead load (5.0 psf) on member(s). 2-3, 3-19, 4-19, 4-22, 5-22, 5-6 7) Bottom chord live load (40.0 psf) and additional bottom chord dead load (0.0 psf) applied only to room. 8-9, 18-20, 20-23, 21-23 E • 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 7=251, i�� • I A 1=257. �•. A Q; 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. �j� • • 4 O R Q • \ ,♦ 10) Attic room checked for U360 deflection. l� • ' • 1� NAk- FL Cert. 6634 June 19,2014 a, WARNIM3 -Verify desr;Tn pan. mernrs ..d READ WES W Mrs AM XMINDED MITER-REFEREA0UF PAGE M77-Z473 rea .1IZ9/20[dNFTX7W!tASE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responslbilllty of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Cdterla, DSB-89 and. BCSI Building Component 6904 Parke East Blvd. SalelyInformation 4v,,,Vble Gom Truss Plate Institute, Tel N. Lee Street, Suite 312, Alexanddo, VA 22331 1 � 1fSauthern(sine SF tunntrerisslxecified,thettesi"_ valuesare thoseeffective45i AtSIC Tampa, FL 33610-4N5 Job Truss Truss Type Qty Ply Gingras Residence " T6375412 27052 • A07 Hip 2 1 Job Reference (optional) tasl 008sI 1 russ, i-on Nleree, rL. 34946 1.0ZU S Apr zz ZU14 MI I ex mausmes, mc. I nu Jun 10! 13:13:34 zu14 rage 1 ID: p?Qm IfchPBBmXvBBT2N Uhez4kwS-5zibs438YVMjNf59SKBrwAX4y2lvOeia9tJgLdz4jd? 5.0.8 9-0-0 , 14-1-8 18-1-0 23-1-8 , 5.0.8 3-11-B 5.1.8 3-11-B 5-0-8 Scale=1:39.2 48 = 3.00 12 4x4 = 3x4 = 3x8 II 3x4 = - 3x4 = 3x8 3x8 = 1.0-o o-4- 7-8.0 . 5-1.8 9.0.0 Plate Offsets (X•Y)-- rl:0-0-0,1-8-131,r1:0-4-8,0-0-21 r3:0-5-4.0-2-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL", in (loc), I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) 0.16 7-9 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.87 Vert(TL) -0.47 7-12 >585 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.20 Horz(TL) 0.10 6 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 98 lb FT = 0% LUMBER- . TOP CHORD 2x4 SP No.2 BOT CHORD 20 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 6=1058/0-8-0, 1=1115/0-8-0 Max Horz 1=64(LC 7) Max Uplift6=-240(LC 5), 1=-254(LC 4) BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-4-11 oc bracing. ' MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=996/217, 1-2=-2637/610, 2-3=-2380/490, 3-4=-2373/510, 4-5=-2458/507, 5-6=-2964/708 BOT CHORD 1-13=-207/926, 1-9=-547/2513, 8-9=-394/2297, 7-8=-394/2297, 6-7=-641/2837 WEBS 2-9=-273/160, 4-7=-19/303, 5-7=-514/253 NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; 6=45ft; L=24ft; eave=4ft; Cat. II; ♦♦ ♦♦♦�S' A'�i,II Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 ♦ I� plate grip DOL=1,60 �♦ P \`r` ,.......•• a �i 3) Provide adequate drainage to prevent water ponding. E N 4) Plates checked for a plus or minus 0 degree rotation about its center. ��`r.••• S'_ • 7i ,9 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. �, �_ , ��• ''r'' 6) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 3 y 3 t3 0 fit between the bottom chord and any other members. * .• 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 6=240, 1 254, 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.-0 O • -�T E ' : �t 40 FL Cert. 6634 June 19,2014 ®WARNItR3•Vedtr dusk7n yanunemrs aad RFiia ng7ES fiN 7fRS,iNUlhY1VAL0 M7TFKR£FLRENCE FAC'LA}ff•MI3 m•1J24J20rQDN'aRF.t/5E Design valid for use onlywith MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek` erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inlorma Ion va able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. lfSouthem ine{SP lumber isspeclf ed, the deftrivalues are thoseeffecltiveOG 0112013byAtSC Tampa, FL 33810.4115 Job Truss Truss Type City Ply Gingres Residence T6375413 2705Y �• AOBG Hip Girder 2 1 Jo a ere ce o do al East Coast Truss, Pon Pierce, FL. 34945 7.520 S Apr 22 2014 WeK Industries, Inc. Thu Jun 19 13:13:3b ZU14 Page 1 I D:p?QmlfchP88mXvB BT2NUhcz4kwS-Z9Gz3Q4nJoUa?ogLO2i4TN3DwS341zxkOX3Du3z4jd_ i 7-0-0 , 11-6-12 16-1-8 23-1-8 _ ' 7-0-0 4-s-12 4-6-12 7-0.0 3.00 F12 3x10 = 4x6 = 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.66 TCDL 17.0 Lumber Increase 1.25 BC 0.94 BCLL 0.0 " Rep Stress Incr NO WB 0.71 BCDL 10.0 Code FBC201O/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP 285OF 1.8E BOT CHORD 2x4 SP 285OF 1.8E WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 5=187710-8-0, 1=1957/0-8-0 Max Horz 1=-49(LC 23) Max Uplift5=-540(LC 5), 1=-567(LC 4) 3x8 = 19 3 20 23 - 7 4x8 1018SHS = 1x4 II 4x6 = 3x4 = Scale = 1:39.5 3x10 = DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.39 8 >719 240 MT20 244/190 Vert(TL) -0.92 8-9 >301 180 M18SHS 244/190 Horz(TL) 0.19 5 n/a n/a Weight: 91 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-10-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-9-6 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-2085/608, 1-2=-5426/1602, 2-18=-5275/1585, 18-19=-527511585, 3-19=-5275/1585, 3-20=-5750/1699, 20-21=-5750/1699, 4-21=-5750/1699, 4-5=-5912/1714 BOT CHORD 1-13=-564/1926, 1-9=-1490/5198, 9-22=-1858/6661,.22-23=-1858/6661, 8-23=-1858/6661, 7-8=-1858/6661, 7-24=-1858/6661, 6-24=-1858/6661, 5-6=-1596/5673 WEBS 2-9=-2231973, 3-9=-1619/408, 3-8=0/375, 3.6=-1126/300, 4-6=-213/984 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.6 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding, 4) All plates are MT20 plates unless otherwise Indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=ib) 5=540, 1=567, 9) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 10) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 127 lb down and 117 ib up at 7-0.0, 127 lb down and 117 lb up at 9-0-12, 127 lb down and 117 lb up at 11-0-12, 127 lb down and 117 lb up at 12-0-12, and 127 lb down and 117 Ib up at 14-0-12, and 127 lb down and 117 lb up at 16-1-8 on top chord, and 437 lb down and 180 lb up at 7-0-0, 53 I down and 5 lb up at 9-0-12, 53 lb down and 5 lb up at 11-0-12, 53 lb down and 5 lb up at 12-0-12, and 53 lb down and 5 lb up at 14-0-12, and 508 lb down and 187 lb up at 16-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on Daae 2 FL Cert. 6634 June 19,2014 ®WARNIM3•Veritydmo. yarur,,eGers,sud RFAB MM7ESON 7 MAW INCIUDED H1TFKR£FERENLEFACEN11-7473ter. 11J.91201dUffMom ■■■ Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsiblllity of the MiTek` erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Edst Blvd. ' Safety Informa Ion va able from Truss Plate Institute. 781 N. Lee Street, Suite 312, Ale andria, Vqq 2314. if5outhern "itle�fiP lumberisspecified,thedesigovatuesairethoseef ectivea6 01/2013 by ALSC Tampa, FL 33610.4115 Job Truss Truss Type City Ply Gingras Residence T6375413 27052a # A08G Hip Girder 2 1 Jo b Refere ce o tionai East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:35 2014 Page 2 ID: p?Qm IfchP88mXvB BT2NUhcz4kwS-Z9Gz3Q4nJoUa?ogL02i4TN3DwS341zxkOX3Du3z4jd_ LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-74, 2-4=-74, 4-5=-74, 10-13=-20 Concentrated Loads (lb) Vert: 2=-99(F) 4=-99(F) 7=-29(F) 9=-437(F) 6=-508(F) 18=-99(F) 19=99(F) 20=-99(F) 21=-99(F) 22=29(F) 23=-29(F) 24=-29(F) ®WARNIM7 Vwify design pan.meta. and READMMMMISAND MaWED MITEKR£FEREt.CE PAGE NII•2473 mR 1140014DffOMM Design valid for use only with M7ek connectors. This design Is based only upon parameters shown, and is for an individual building component. �• so Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing 10 Insure stability during construction is the responsibillity of the MOW Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component fabrication, 6904 Parke East Blvd. Safety Inlormatlon vo able from Truss Plate Institute, 781 N. Lee Street. Suite 312, Alexandria, VA 2314. lf5authern 1ne7fiP lumberisspecified,thedesignvalues are those effettilreOfi1O1J1013byRtSC Tampa, FL 33610-0115 Job Truss Truss Type City Ply Gingras Residence T6375414 27MO 4, B01G Roof Special Girder 1 • 1 ob a e ence o do a East Coast Truss, Fort Pierce, FL. 34946 ' 7.520 s Apr 22 2014 MTek Industries, Inc. Thu Jun 19 13:13:36 2014 Page 1 ID:p7QmlfchP88mXvBBT2NUhcz4kwS-1 LgLGm5P46cRdyFYalEJ7bcTIsV9UaStdBonPWz4jcz L 5-4-10 8-8-1 13-8-1 5.4-10 3-3-8 5-0-0 Scale=1:22.8 44 = 2.79 12 4x8 = 3.00 112 3x8 II 3x4 = 1x4 II 3x4 = 1-110 1-4-15 5-4-10 8-8-1 ,."613.8-1. 1-0 b-453-11-11 3-3-8 5-0-0 Plate Offsets (X.Y)— fl:0-0-0.1-10-81 f1:0-4-15 0-0-21 f3:0-5-4 0-2-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) 0.07 5-7 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.57 Vert(TL) -0.17 5-7 >949 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.12 Horz(TL) 0.04 4 n/a n/a BCDL 10.0 Code FBC�01 OrrP12007 (Matrix-M) Weight: 50 lb FT = 0% LUMBER- BRACING-* TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-10-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-11-9 oc bracing. WEBS 2x4 SP No-3 MiTek recommends that Stabilizers and required cross bracing WEDGE be installed during truss erection, in accordance with Stabilizer [installation Left: 2x4 SP No.3 REACTIONS. (lb/size) 4=784/0-8-0, 1=802/0-8-10 Max Horz 1=-32(LC 6) Max Uplift4=-227(LC 5), 1=-232(L'C 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces. 250 (lb) or less except when shown. TOP CHORD 1-1=-687/199, 1-2=-1713/503, 2-16=-1657/503, 3-16=1657/503, 3-4=-2031/607 BOT CHORD 1-11=-183/636, 1-7=-445/1639, 7-17=-552/1967, 6-17=-552/1967, 5-6=-552/1967, 4-5=-545/1934 WEBS 3-7=-436/227.3-5=-66/315 NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; ,,'i111111/I�/I Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 ,�� S A l't plate grip DOL=1.60 �� A� Provide adequate drainage to ptevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about Its center, ♦♦� •� (✓ E N �`r.• �, /f �• �•• `"• 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • �, Pa 3 938 0 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 0 + * fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except Qt=lb) 4=227, i — 1=232. 8) Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. _ •�t� 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 88 lb down and 90 lb up at 6-9-6, �� .;' ATE : �W and 88 lb down and 90 lb up at 8-8-1 on top chord, and 23 Ito down and 12 Ito up at 6-9-6, and 214 lb down and 114 lb up at 8-7-5 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. ;C �j�,�c�• P`•• 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). `Q ♦♦ ��'s/O N A1- �,1� LOAD CASE(S) Standard t111111110 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-74, 2-3=-74, 34=-74, 8-11=-20 Continued on Dame 2 FL Cert. 6634 June 19,2014 ® WARNING -Verdi desrdn panmeW. and READ N07ES ON TNTSANO MCUIDED MTTEKR£FERME PACE MIJ-7423.. 11291ZOUMOMME Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responslbillity of the WOW Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPIi Quality Criteria, DSB-89 and BCSI Building Component fabrication, 6904 Parke East Blvd. Safety Informa Ion va able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. It SouthernPine�SP� lumber isspecified, the design values are those effective 461101/2013 by ALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375414 270570 41 601G Roof Spacial Girder 1 1 b fere ce o t'o al East Coast Truss, Fort Pierce, FL. 34946 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-39(B) 5=214(B) 16=-39(8) 17=-8(B) 7.520 s Apf 22 2014 MiTBK Industries, Inc. Thu Jun 19 13:13:36 2014 Page 2 ID: p7Qm IfchP88mXvBBT2NUhcz4kwS-1 LgLGm5P46cRdyFYaIEJ7bcTIsV9UaStdBonP Wz4jcz �WARNIff •Y.&V desirPr rammemrs and READ A07ES ON TRTS AND IMIUDED M1TEKREFEREKE PAGE Mfi•7473 m a 212V20168170unm Design valid for use only with Mffek connectors. This design Is based only upon parameters shown, and Is for an individual building component. �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB•89 and BCSI Building Component 6904 Parke East Blvd. Safely Inlormatlon gva' able from]russ Plate In titute, 781 N. Lea Street Suite 312, Alexandria, Vq 2314. Tampa, FL 33610.4115 If Southern P"iT1e {SP� lumber ss sp ecif iec , the design values are those effeitiTre Qfi/01/2013 by ALSC Job Truss Truss Type Qty Ply Gingras Resitlenca T6376416 27053 B02 Roof Special 1 1 Jo a ere ce o io al East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:36 2014 Page 1 ID:p?QmlfchP88mXvBBT2NUhcz4kwS-1 LgLGm5P46cRdyFYalEJ?bcQ2sWZUaptdBonP Wz4jcz 6-2-2 13-1-12 6-2-2 6-11-10 Scale=1:21.6 4x4 2.79 12 3 .Ann 119 6 Tx4 n 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.57 TCDL 17.0 Lumber Increase 1.25 BC 0.48 BCLL 0.0 ' Rep Stress Incr YES WB 0.10 BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 SLIDER Left 20 SP No.3 1-6-0 REACTIONS. (lb/size) 1=590/Mechanical, 4=646/0-8-0 Max Horz 1=-42(LC 6) Max Upliftl=-164(LC 4), 4=-165(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-753/133, 2-3=-1229/332, 3-4=-1443/413 BOT CHORD 1-5=-267/1158, 475=-435/1509 WEBS 3-5=0/256 DEFL. In (loc) .I/deft Ltd Vert(LL) -0.06 5-12 >999 240 Vert(TL) , -0.18 5-12 >891 180 . Horz(TL) 0.02 4 n/a n/a PLATES GRIP MT20 244/190 Weight: 44 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=0ft; B=45ft; L=24ft; eave=4ft; Cat, II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 j111111111rrr� 3) Plates checked for a plus or minus 0 degree rotation about its center. ,�� s A. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. P 5 • This truss has been designed for a live load of 20.0 sf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. ,` �, F '.�!% i 6) Refer to girder(s) for truss to truss connections. G 39380 ` 7) Provide mechanical connection (by others) of truss to beating plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b) 1=164, 4=165. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. • _ AT E to ;��•O�F �� OR 10 rrrrrrnn►j11� FL Cert. 6634 June 19,2014 ,&WARNIAG-VerslydesgaparameoenandRF4D MWESGM7MSAN0 IMIUDFDMITEKREFEREAtE PAGE k11- 7423 rea1/29/201daff0 WE Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the erector, Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek' fabrication, quality control, storage, delivery, erection and bracing, consult ' ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inlormotion va able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria. VA 2314. If 6outhe rn Rine�SP� lumbe r is specified, the design values are those effective Ob j0112013 by ALSC Tampa, FL 33610.4115 Job ' Truss Truss Type Qty Ply Gingras Residence • T6375416 27052• � 803 Roof Special 1 1 Jo efe erica o do a East Coast Truss, Fort Pierce, FL. 34946 5-0-8 4x4 2.79 12 7.520 a Apr 22 2014 MITBK industries, inc. I nu Jun 19 1J:1J:Jr 2U14 F'age 1 I D:p?QmlfchP88mXvB BT2NUhcz4kwS-VYOkU651 rQklE6gk7TIYYo9ZGFsWD1 Al rrYKxyz4jcy 13-1-12 7-4-4 Scale=1:21.7 3x8 II 1x4 ii 3x4 = LOADING (psf) SPACING- 2.0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.67 TCDL 17.0 Lumber Increase 1.25 BC 0.49 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 BCDL • 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 SLIDER Left 2x4 SP No.3 1-6-0 REACTIONS. (lb/size) 1=583/Mechanical, 4=65310-8-0 Max Horz 1=-43(LC 6) Max Uplift 1 =-1 61 (LC 4), 4=-168(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1121/303, 3-4=-1614/461 BOT CHORD 1-5=-233/1052, 4-5=-490/1700 DEFL. in (loc) Udefl Ud Vert(LL) 0.08 5-12 >999 • 240 Vert(TL) -0.23 5-12 >673 180 Horz(TL) 0.02 4 n/a n/a PLATES GRIP MT20 244/190 Weight: 44 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer guide,Installation NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=0ft; 6=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ��,,0\V`P,• • A�e �j fit between the bottom chord and any other members. G E N S •• q�1�is 6) RefeP to girder(s) for truss to truss connections. `��,` �.� E•_•.•,:r.` ! 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=161, 4=168. 0 3938OOy 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ;ram 'O••" 'SATE •40 FL Cert. 6634 June 19,2014 ® WARNi7✓j •Verity design yaramemra aad RFi1D tA7£S GN7lilSAND IM117D£D MIT£KR£F£R£NCF MiGE NI!•7473 yea IJd9/IO1QaFFGHEUSE Design valid for use only with MiTek connectors. This design is based only upon parameters •shown• and Is for an Individual building component, Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing. consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informatign vatlIable from Truss Plate In titute, 781 N. Lee gireet, Suite 312, Alexandria, VA zz2314: Tampa, FL 33610.4115 , if5out lem Vine SP lumber issfueeilieT ,thedeMgn values arethoseeffective 06)01%2013byAtSC' Job Truss Truss Type Qty Ply Gingras Residence T6376417 27059 • 804 Roof Special 1 1 Job Reference footionah East coast Truss, Fort Pierce, FL. 34946 5-4-14 4x4 2.79 12 7.620 a Apr 22 9014 MiTeK Intlustnes, Inc. Thu Jun 19 13:13:37 2014 Page 1 I D:p7QmlfchP68mXvB BT2NUhcz4kwS-VYOkU651 rQklE6gk7TIYYo9YnFrxD1 H 1 rrYKxyz4jcy 13-1-12 7-8-13 Scale=1:21.5 1x4 it 3x4 = 5-4-14 7-8-13 Plate Offsets (X,Y)— (1:0-1-12.0-1-71 LOADING (psf) SPACING- 2-0.-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.76 Vert(LL) 0.10 5-12 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.53 Vert(TL) -0.29 5-12 >551 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.08 Horz(TL) -0.02 1 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 47 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 SLIDER Left 2x8 SP No.2 1-6-0 REACTIONS. (lb/size) 1=578/Mechanical, 4=658/0-8-0 Max Harz 1=-44(LC 6) Max Upliftl=-158(LC 4), 4=-170(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-411/71, 2-3=-1035/281, 3-4=-1761/506 BOT CHORD 1-5=-205/968, 4-5=-540/1865 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-2-2 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuit=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0,18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates has bee ncked for a plus or minus 0 degree rotation about its center. 4) This trussn designed for a 10.0 psf bottom chard live load honconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will. 0••,`J. �r fit between the bottom chord and any other members. , p � E N,3 ••• 6) Refer to girder(s) for truss to truss connections. ,�,`%.'•�.� ��'..9�li 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift atjoint(s) except (jt=lb) 1=158, 4=170. ` * ; • Pao 3938 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LATE �✓ i Qom A%�� • � O ��P s/ONALE��``� �,1nn 1 n+11 FL Cert. 6634 June 19,2014 ®WARMA0 •Verffydes4a pars Mn•ad READ AVIESaM 7MTSAM0INCLUDED MITEKREFEREMX PAGE Mll-7473 re• I1291201dVET OSE Design valid for use only with M1ek connectors. This design is based any upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown ' Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity, of the M'Tok• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication. quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va' able from Truss Plate In titute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. 1f5outhemPine�SP lumberisspec->tier, theclesignvaluesarethwoeffactive461Q1f2013byAtSC Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence T6375418 27052 ' C01G Roof Special Girder 1 1 o e e ence do al Cast l:0asl 1 rues, t-on Nlerce, f•L. 34945 7.520 S Apr 22 2014 MITex Industries, Inc. Tnu Jun 19 13:13:39 ZU14 Naga 1 ID:p7Qm IfchPBBmXvB BT2NUhcz4kwS-RwV,AJvo7HN 1_000z7FunOdDEvp3a5gp7JJ91 ROrz4jcw t 4-5-9 7-'0-1 11-9.8 14-8-6 16.8-1 21-6-11 23-1-8 r 4.5.9 3-4-9 3-11.7 2-10.14 1-11-11 4-10.9 1.6-13 3.00 12 3x4 = 3x8 11 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 17.0 Lumber Increase 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2010/TP12007 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* 6-8: 2x6 SP No.2 1.37112 4x4 = CSI. TC 0.66 BC 0.36 WB 0.58 (Matrix-M) 5x6 = 11 10 5x5 = DEFL. in (loc) Vert(LL) 0.09 9-11 Vert(TL) -0.11 9-11 Horz(TL) 0.01 11 BRACING- . TOP CHORD BOTCHORD WEDGE Left: 2x4 SP No.3 REACTIONS. All bearings 1-8-7 except Qt=length) 1=0-8-0, 11=0-6-0. (lb) - Max Horz 1=40(LC 31) Max Uplift All uplift 100 lb or less at joints) 7 except 8=-163(LC 8), 1=-241(LC 4), 11=-1204(LC 4) Max Grav All reactions 250 lb or less at joint(s) 7, 8, 7 except 1=643(LC 36). 11=1336(LC 36) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1 -1 =-487/206, 1-2=-1233/557, 2-3=-1075/825, 3-22=-1043/799, 4-22=1058/764, 4-23=-603/716, 23-24=-598/705, 5-24=-603/683, 5-25=-615/314, 6-25=-634/310, 6-7=-604/298 BOT CHORD 1 1-17=-202/460, 1-12=-516/1196, 12-26=-684/645, 11-26=684/645, 10-11=-284/611, 10-27=-284/611, 9-27=-284/611, 9-28=-284/611, 8-28=-284/611, 7-8=-265/596 WEBS 2-12=-639/363,4-11=-11621747,4-12=-1113/1481.5-11=1204/923 I/defl Ud >999 240 >999 180 n/a n/a Scale = 1:39.2 3x4 = PLATES GRIP MT20 244/190 Weight: 95 lb FT = 0% Structural wood sheathing directly applied or 5-3-2 oc purlins. Rigid ceiling directly applied or 6-0-0 cc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide, NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 7 except Qt=lb) ,,,,,BPS I A. /���i � O� G. , E. IVS� •y ii `�� �� .' �,�_ • .� Ali i Pd6_39380 ��• ;ram ATE ': 441 Z. 0 8=163, 1=241, 11=1204. ./ is `G � 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.SQ �G\ %%� 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 308 lb down and 625 lb up at �����, N A` �� 7-10-1, 134 lb down and 118 lb up at 10-0-5, 103 lb down and 103 lb up at 12-3-5, 83 lb down and 87 lb up at 14-6-5, 63 lb down and 70 lb up at 16-9-5, and 38 lb down and 57 lb up at 19-0-5, and 88 lb down and 192 lb up at 21-6-11 on top chord, and 379 lb down and 188 lb up at 7-9-6, 50 lb down and 127lb up at 10-0-5, 32 lb down and 53 lb up at 12-3-5. 20 lb down and 32 lb up at 14-6-5, and 8 lb FL Cert. 6634 down and 16 lb up at 16-,9-5, and 56 lb down and 38 lb up at 19-0-5 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. June 19,2014 %Aflrtbf;�Pag,AgE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). &WARNINJ Nerift,design pammeters and READ h07ESG7 TNTSAND IM27.UDED MITEKREFERE,AKEAAGE NII-7473 mr. 1119120148ffMME ■ Design valid for use only with MOek connectors. This design is based only upon parameters shown, and Is for an Individual building component. �• Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the WOWerector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va able from Jruss Plate Institute, 781 N. Lee g5ireet, Suite 312, Alexandria, VA 2314. 1i5authernp'ine75P lumber isspetified,thedesignvafuesarethoseeifectire,06 01/1013byALSC Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence • T6375418 27057 a, C01G Roof Special Girder' 1 1 Job Reference (optional East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITeK Industries, Inc. Thu Jun 19 13:13;39 2014 Page 2 ID:p?QmlfchP8BmXvBBT2NUhcz4kwS-RwVWvo7HN1_OUQz7FunOdDEvp3a5gp?JJ91ROrz4jcw LOAD CASE(S) Standard 1) Dead'+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=74, 3-6=-74, 6-7=-74, 13-17=-20 Concentrated Loads (lb) Vert: 3=290(F) 6=96(F) 10=-17(F) 12=180(F) 9=10(F) 5=2(F) 22=-94(F) 23=63(17) 24=-32(F) 25=39(F) 26=-27(F) 27=-5(F) 28=24(F) ®WARNIAG -Verify d.si7n parame[en and READ M)7E5GN7N7SAND Ir aUDED MIIMEFEREAK7 PAGE HH-M73 rea I129/2014MYOUME Design valid for use any with M1ek connectors. This design is based only upon parameters shown, and is for an individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding ' fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 69D4 Parke East Blvd. Spfety Informapn vat able from Truss Plate Institute, 781 N. Lee Street, Suite 312, AI xandria, VA 2314. ft fsDLYhCFl1 PIIlE7 ial1mber lsspecifled,the des:ign values are those'£�C4Y1V£Q`%Qi%20%3byAtSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375419 2705£ CO2 Roof Special 1 1 Job Reference (optional East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:40 2014 Page 1 ID:p7QmlfchP88mXvBBT2NUhcz4kwS-w74s678v8L6t5aYJpblFARn3MTvdPK_TXpm_YHz4jcv 5.0.14 9-0.12 11-9-8 13.8-1 18-3.5 23-1-8 , 5-0-14 3-11-14 2.8.12 1-IN 4-7-5 4.10-3 3.00 12 3x4 = 3x8 II 4x4 = 3x4 = 98 3x8 = 5x5 = LOADING (psf) SPACING- 2,0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.68 TCDL 17.0 Lumber Increase 1.25 BC 0.40 BCLL 0.0 ' Rep Stress ]nor YES WB 0.34 BCDL 10.0 Code FBC201 O/TP 12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 6=421/0-8-0, 1=470/0-8-0, 9=1282/0-6-0 Max Harz 1=54(LC 7) Max Uplift6=-359(LC 5), 1=-81(LC 4), 9=-603(LC 4) Max Grav6=443(LC 18), 1=505(LC 13), 9=1282(LC 1) 1.37112 DEFL. in (too) I/deft Ud Vert(LL) 0.13 7-9 >999 240 Vert(TL)-0.1610-18 >899 180 Horz(TL) 0.02 6 n/a n/a Scale = 1:39.2 3X4 PLATES GRIP MT20 244/190 Weight: 98 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-9 MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-336/31, 1-2=-768/75, 4-5=-289/590, 5-6=-847/688 BOT CHORD 1-14=-32/311, 1-10=-51/767, 9-10=-556/346, 8-9=-623/787, 7-8=-623/787, 6-7=-707/871 WEBS 2-10=-663/282, 5-7=-269/226, 4-9=-932/205, 4-10=-147/675, 5-9=-1286/981 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. If., tt%j f f fit A. gust) Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch right ,�*$% PS ...... �e �♦♦ exposed; Lumber DOL=1.60 plate grip DOL=1.60 ,�� off`. •, .• G E N, '• -9 ♦♦ ' 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. �� ; V�'r•.V�! 39380 ---.- 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except at=lb) 6=359- Z , 9=603. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss, = Xx • O •-T E '�� ; i���ss�O N,A1- �0� ffff11111% � FL Cert. 6634 June 19,2014 ®WARNII!"i •VcritydesRjn ram—tea-dREAD A07ESGN7705AND INr7.IADED MI7FKREFEREhGEPAGEMII-T473 mti I12f120148DICULM Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown ' is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek erector, Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Spf ty Information va able from Truss Pla)e Institute, 781 N. Lee Street, Suite 312, Alekandria. V a231/4 i1 llSfrt••rR F�IfY2� {Y�lumber isspeciliei,the design values 3Te thost i'ffi�ctive ��ft�If IQ13` yy At.SC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375420 27051 • -CJ1 Jack -Open 9 1 Job Reference o tiona East Coast Truss, Fort Pierce, FL, 34946 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 1913:13:40 2014 Page 1 I D: aTo5i8u3YiaH LhcfyS I Q Fyz4kxO-w74s678v8L6l5aYJpblFARn DTT7w P P KTXpm_YHz4jcv 1-0-0 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 17.0 Lumber Increase 1.25 BCLL 0.0 • Rep Stress Incr YES BCDL 10.0 Code FBC2010/TP12007 LUMBER - TOP CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=36/Mechanical, 2=36/Mechanical Max Horz 2=12(LC 4) Max Upliftl=-17(LC 4), 2=-14(LC 4) Scale = 1:5.6 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 0.03 Vert(LL) -0.00 1 >999 240 BC 0.00 Vert(TL) -0.00 1 >999 180 WB 0.00 Horz(TL) -0.00 1 n/a n/a (Matrix-M) Weight: 2 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-6oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide, FORCES, (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. 5) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. A,f q,Jn* ,,`,PS `� Q`"• G 49 Fig'_ 93 380�-�5 r ATE 41j-;4 O /O. .�,F•'c40R1 P •����• O E?G N AL FL Cert. 6634 June 19,2014 AWARNIM •Vent} desc7n p.m.,em,y -d READ M17ESWWSAND IAMDED MIIEKREFERENX PAGE Mri-M73 nt R I1251120148a''OMME Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown pp pp Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the �y� iTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/71`I1 Quality Criteria, DSB-B9 and BCSI Building Component 6904 Parke East Blvd. Sa ety InformallIon gva able from Truss Plate Institute, 781 N. Lee Street, Suite 312, AI xandria, VA 2314 Tampa, FL 33610-4115 if uthemisinetSP lum eri"Pecifietfrthedesignvaluesartth see#eitixe06 03J$013byAM Job Truss Truss Type Qty Ply Gingras Residence T6375421 2705C • -CJ1B Jack -Open 3. 1 Job Reference (optional East Coast Truss, Fort Pierce, FL. 34946 i_n_n 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:40 2014 Page 1 ID:p?QmlfchP88mXvBBT2NUhcz4kwS-w74s678v8L6t5aYJpbIFARnDTT?wPPKTXpm YHz4jcv Scale =1:5.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase - 1.25 TC - 0.03 Vert(LL) -0.00 1 >999 240 TCDL 17.0 Lumber Increase 1.25 BC 0.00 Vert(TL) -0.00 1 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 • n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 2 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.3 REACTIONS. (Ib/size) 1=36/Mechanical, 2=36/Mechanical Max Horz 1=12(LC 4) Max Upliftl=-14(LC 4), 2=-17(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MITek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. 5) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 0111111 trio 393 80 •'--- F): • :. OR X 0`�, �►r1in1 AWARNIMI-Yedfy:fs*jn Pammemrsond READ M77UGV77A5AWInaUDED MIUKREEERENC£FAGEM11-7473 m•. 11291201da2HUM4 ' Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and_proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional. permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component SafetyInformation 7varble from jruss Plate In{titute, 781 N. Lee Street, Suite 312, Alexandria, VA 2z314 If Southern ine SP lumbetrssoecifie,thedesienuaiuesarethmeeffective06fdif Dl3bi,At5C FL Cert. 6634 June 19.2014 t MITek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375422 270% - • -CJ2 Jack -Open 2 1 Job a ere ce o tional East Coast Truss, Fort Pierce, FL. 34946 1-5-15 7.520 S Apr 22 2014 MiTeK Industries, Inc. TDu Jun 19 13;13:41 ZU14 rage 1 I D:p?Qm IfchP88mXvB BT2N Uhcz4kwS-OJdEKT8YveEjjk7VMlpUieJNBlJzBsacmTWY4jz4jcu Scale = 1:6.3 i-se ao- Plate Offsets (X,Y)— 11:0-7-12.0-0-81,f1:0-1-4,Ednel LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.10 Vert(LL) -0.00 5 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.00 5 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/rP12007 (Matrix-M) Weight: 5 lb FT = 0% LUMBER- BRACING. TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-5-15 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer installation REACTIONS. (lb/size) 1=312/0-4-13, 4=-1 01 /Mechanical, 2=-67/Mechanical Max Horz 1=19(LC 4) Max Uplift 1=-251(LC 4), 4=-101(LC 1), 2=-67(LC 1) Max Grav 1=312(LC 1), 4=74(LC 4), 2=53(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 11111 fit between the bottom chord and any other members. ���� S A 1�I� 5) Refer to girder(s) for truss to truss connections. ��� �P... .. .�e 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 1=251 `�� "� ,•'`G E N S •• '9 �� 7) "Semi -rigid pitch brest ks including heels" Member end fixity model was used In the analysis and design of this truss.3938 ` 0 Mir Z ATE • Cu . s/O N A1- G FL Cert. 6634 June 19,2014 ®WARNING-Vdfrdesign Tara M. and READ A07ESON718SAW INCLUDED MITFK1iffEREh1WPAGEM11-M73 ma 11291201JETMEME Design valid for use only with Wek connectors. This design is based only upon parameters shown, and Is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown , is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the WOW Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSO.89 and BCSI Building Component fabrication, 69D4 Parke East Blvd. Safety Informa Ion va' able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. 115outhern ine�SP lumber issuecified.thedeslerlvalues are tflaseeffective06.0 1201391v✓ LSG Tampa, FL 33610-4116 Job Truss . Truss Type Qty Ply Gingras Residence T6375423 2705E -CJ3 Jack -Open 9 1 Job e e e ce o tiona tasi l:oa51 I cuss, Von HIM% t-L.'s4s4a 7'520 a Apr 22 2014 MITBK Indusines, Inc. Tnu Jun 19 1J:13:41 2a14 Yage 1 I D:p7QmlfchP88mXvBBT2N Uhcz4kwS-OJdEKT8YveEjjk7VM IpU1eJMItKA8sacmTWY4jz4jcu 3-0-0 3-0-0 REFER TO MITEK "TOE -NAIL" DETAIL FOR CONNECTION TO SUPPORTING CARRIE Scale = 1:8.2 _Elate Offsets (X.Y)-- rl:0-7-0.0-0-81 r1:0-1-4 Edoel LOADING (psf) " SPACING- 2-0-0 CSI. DEFL. in (too) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.00 6 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.13 Vert(TL) -0.01 6 •>999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 9 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 3-0-0 cc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer installation e REACTIONS. (lb/size) 1=23410-8-0, 2=50/Mechanical, 5=-51Mechanical Max Herz 1=37(LC 4) Max Upliftl=-57(LC 4), 2=-28(LC 4), 5=-5(LC 1) Max Grav 1=234(LC 1). 2=50(LC 1), 5=18(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. Ii; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about Its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will �111 1 jI l l fit between the bottom chord and any other members. ♦,♦� PS A. A �I� 5) Refer to girder(s) for truss to truss connections. ♦ ••,. 4 . 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 5. ,��♦ •'\ G N S • • 4 7) "Seml-rigid pitchbreaks.including heels" Member end fixity model was used in the analysis and design of this truss. `� ,`�.•.�. __�',•� 3938 - Xx Z r • � O.•'- ATE :mow /ON AL i • ...•• FL Cert. 6634 June 19,2014 JAL WARNIAG •Verify design Paramemn aad READ AVTESGN 770SAND lM1VDED M7TEKREFEREKEPAGE N11-M23 — I129/201dDE OWME Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component., Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsiblllity of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va able from Truss Plate In titufe, 781 N. Lee Street, Sulfe 312, Alexandria, Vqq 2314. !fSautilernivine7SPI lumberisspetifierg,thedesignvaluesarethoseeffectiveOfi 01/2013byALSC Tempo, FL 33810.4116 Job Truss Truss Type Qty Ply Gingras Residence T6375424 2705Q A -CJ313 Jack -Open 3 1 Job Reference (optional East Coast Truss, Fort Pierce, FL. 34946 . 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.14 TCDL 17.0 Lumber Increase 1.25 BC 0.16 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=149/0-8-0, 2=85/Mechanical, 5=46/Mechanical Max Horz 1=37(LC 4) Max Upliftl=-35(LC 4), 2=36(LC 4), 5=-4(LC 4) Max Grav 1=149(LC 1), 2=85(LC 1), 5=57(LC 3) FORCES, (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:42 2014 Page 1 ID: p?Qm IfchP88mXvB BT2NUhcz4kwS-sVBdXp9AgyMaLtiiwOKj FssXAGeztJpm?7F5c9z4icl 3-0-0 Scale =1:8.2 3-0.0' DEFL. In (loc) I/deft Ud PLATES GRIP Vert(LL) ' -0.00 8 >999 240 MT20 244/190 Vert(TL) -0.01 5-8 >999 180 Horz(TL) 0.00 1 n/a n/a Weight: 9 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit 5) Refer to girder(s)foeen the bottorntruss to truss connections. chord and any other tiers.A1II�.��,� 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 1, 2, 5, ��P;• • 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ,♦ ,•'\ 0E S ♦ � • • V -�•, li i �• 0 39380 .�— Tt . . rZ ` • l ATE �•`" �p N A1-E� �`�� FL Cert. 6634 June 19,2014 AWARNMR3•Vedfy design p—em. and READ tMESONTNrSAM rNILUDED NTTEKR£FERENCEMENTr-2473m. 2129120i WOMME Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for on Individual building component. Applicability of design paramefers and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the WOW Additional permanent bracing of the overall structure Is the responsibirity, of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component fabrication, 69D4 Parke East Blvd. Safety Intorma Ion Ova able from Truss Plate In titute, 781 N. Lee Street. Suite 312, Ale andria, VA 2314 - lfSouthern "ina{SP lumberisspeiiiieds,thedesignvaluesarethoseaflxecirveO6 01JI913byALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375425 27052 • ° -CJ4 Jack -Open 2 1 Job Re ere ce o tional East Coast Truss, Fort Pierce, FL. 34946 4.5-6 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:42 2014 Page 1 ID: p?Qm IfchP88mXvB BT2NUhcz4kwS-sV BdXp9AgyMaLtiiwOKjFssVdGeftJpm?7F5c9z4jct Scale = 1: 10.0 - -_-- 1-0-0 0-4-0 2-11-8 1-1 Plate Offsets X,Y)-- 11:0-7-0,0-0-81 f1:0.1-4,Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.31 Vert(LL) -0,00 5-9 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.18 Vert(TL) -0.01 5-9 >999 180 SCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-5-6 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation REACTIONS. (lb/size) 1=291/0-8-0, 2=99/Mechanical, 5=23/Mechanical Max Horz 1=55(LC 4) Max Uplift 1 =-72(LC 4), 2=-48(LC 4) Max Grav 1=291(LC 1), 2=99(LC 1), 5=52(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 pelf bottom chard live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit.between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. �P• 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. 7) "Semi -rigid including heels" Member fixity in the design this truss. %�� ,. `���0 ,•'� G ENS '•.-9�'�� V �.�.•,�. pitchbreaks end model was used analysis and of ., A� �_�-- - P4 39380 � 1 ' Mij: ATE ' '�: Off. .• EEC % �4.0 NA FL Cert. 6634 June 19,2014 ®WARNING-Ven1ydesd7e Paramarers aad RFAD 107ESG777N7SAND INCLUDED MITEKREfEREACE PAGE MII-7473 ma 1I39/201daf ot(EME Design valid for use only with MTek connectors. This design 4 based only upon parameters shown, and is for an individual building component.' f Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding iVliTek' fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component Sgfety Informatlon Iva able from Truss Plate Institute, 781 N. Lee S5treet, Suite 312, Ale andria, VA pp2�314 1t5autheFn rne�SP lumberisspeclfied,thedesignvaEuesatetho3eef>xecttueG'6AA1Z2013hgALSC 6904 Parke East Blvd. Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence T6375426 27051 • •CJ5 Jack•Open 8 1 Job Reference (optional East Coast Truss, Fort Pierce, FL. 34946 5-0.0 1 7.520 s Apr 22 2014 MTek Industdes, Inc. Thu Jun 1913:13:43 2014 Paget. ID:p7QmlfchP88mXvBBT2NUhcz4kwS-Ki1719AoRGURyl HuUjsyn3PevgzPcm3vEn7e9cz4jcs Scale=1:10.7 LOADING (psf) TCLL 20.0 . TCDL 17.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC201 O/TP12007 CSI. TC 0.40 SC 0.21 WB 0.00 (Matrix-M) DEFL. In Vert(LL) . -0.01 Vert(TL) -0.01 Horz(TL) -0.00 (loc) I/defl Ud 5-9 >999 240 5-9 >999 180 2 n/a n/a PLATES GRIP MT20 244/190 Weight: 15 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer guide,installation REACTIONS. (lb/size) 1=320/0-8-0, 2=117/Mechanical, 5=30/Mechanical Max Harz 1=62(LC 4) Max Upliftl=-79(LC 4), 2=-57(LC 4) Max Grav 1=320(LC 1), 2=117(LC 1), 5=64(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=0ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. .% p,S A 5) Refer to girder(s) for truss to truss connections, �� ,,....... ., 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. ' �6, , ••� G E N S+ •• '9 rr� 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. `� ,` ; • f!.__��•,�! N0 3 9 3 8 0.,.--- - *: • V ATE r � OR FL Cert. 6634 June 19,2014 ®WARNIAG Vedlydes7a pa umewn,rnd RFitt)tATTBGN TNrSANDfNC1UDEb M77EKR£FEREhCE PAGtNr!•7473 mR IJ24/20iJBtFOAEtdSE Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component.' Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the MOWerector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BC51 Building Component 6904 Parke East Blvd. Safety Information vo able from Truss Plate Institute. 781 N. Lee Street, Suite 312, Alexandria, Vqq 2314. Tampa, FL 33610.4115 IfSoutfiern uteiSP�lumberisspecified,thededignvaluesarethoseeffective06 01/2013.byAt:SC Job Truss Truss Type Qty Ply Gingras Residence T6375427 2705% • -CJ5B Jack -Open 2 1 ' Job Refe ence o do a East Coast Truss, Fort Pierce, FL. 34946 5-0-0 3x4 = 7.520 s Apr 22 2014 MITBK Inauslnes, Inc. [nu Jun le 15:13:4J ZU14 1,8g8 1 ID:p?QmlfchP88mXvBBT2NUhcz4kwS-Kil?19AoRGURyl HuUjsyn3PdogxXcm3vEn?e9cz4ics Scale=1:10.7 5-0.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.47 Vert(LL) -0.02 5-8 >999 240 MT20 2441190 TCDL 17.0 Lumber Increase 1.25 BC 0.33 Vert(TL) -0.06 5-8 >956 180 BCLL • 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 1 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 15 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=267/0-8-0, 2=1401Mechanical, 5=60/Mechanical Max Horz 1=62(LC 4) Max Uplift1=-65(LC 4), 2=-62(LC 4) Max Grav 1=267(LC 1), 2=140(LC 1), 5=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-600/174 BOT CHORD 1-5=-214/632 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ,111111 lllll1 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will �* S /ta �I� fit between the bottom chord and any other members. t�� �P,. • • • .. 44'e 5) Refer to girder(s) for truss to truss connections. 0,• C'EN, •• 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. ,` ; • �.� ��.•,.7! 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 39380 * •tir ATE i�"1S10 N A` E %%N FL Cert. 6634 June 19,2014 WARNING -Verify design p..e Mrs aadREAD 10TESON 77ITSAM MaUDED MITEKREFEREM,Fh70E M11.7473 re 4 I12912016BEEOMME Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responslbillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding ' fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI7 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. S lety Information val able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA2314. i Southo,rnlrille�SP lumber isspetiiied, the design uIluesart those�effective06140112013byALSC Tampa, FL 33610.4115 Job Truss Truss Type Ply Gingras Residence T6375428 27052k • DOIG Roof Special Girder �Qty 1 1 Jo b Reference o do al east coast I russ, Pon Pierce, FL. 34946 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:44 2014 Page 1 I D:p?Qm IfchPBBmXvB BT2NUhcz4kwS-ouJNyVBQCZclaBs42RNBKHxlP4LYLD03SRkCh2z4jcr 2-8-0 3-7-3 7-2-14 2-8-00.11-3 3-7-12 4x4 = 3.00 12 LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr NO Code FBC201 O/TPI2007 CSI. TC 0.16 BC 0.08 WB 0.06 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 *Except* 3-4: 2x4 SP 285OF 1.8E BOT CHORD 20 SP 285OF 1.8E WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=307/0-8-0, 4=187/1-5-8 Max Harz 1=19(LC 4) Max Uplift 1=-169(LC 4), 4=-71(LC 4) Max Grav 1=342(LC 36), 4=197(LC 36) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-275/236, 2-3=-262/212, 3-4=-276/208 BOT CHORD 5-6=-213/261. 4-5=-1981276 4x4 = 1.37112 US II 3x4 = Scale=1:14.0 DEFL. In (loc) I/deft Ltd PLATES GRIP Vert(LL) -0.01 13 >999 240 MT20 244/190 Vert(TL) -0.02 13 >999 180 Horz(TL) -0.00 4 n/a n/a Weight: 27 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as perANSIfTPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. . 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection.(by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb) 1=169. 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 11) Hanger(s) or other connection devlce(s) shall be provided sufficient to support concentrated load(s) 115 lb down and 230 lb up at 2-8-0, and 31 lb down and 71 lb up at 5-1-12 on top chord, and 36 ib down and 103 lb up at 2-8-0, and 22 lb down and 47 lb up at 3-7-3, and 1 lb down and 44 lb up at 5-1-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on Daae 2 `���0.•�p�E�N,9 0 39380 ATE t(1 1111t1{{ FL Cert. 6634 June 19,2014 ,& wARNRr • Verify des4a p.m.,eNrs a.d READ h07ES Olt TMSAW JAUUDED MITEKREEEREACE PAGE HII.7423 mw I/291201dWOMME Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MOW fabrication, Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSVIPII Quality Crlterla, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information va' able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexonddo, Vqq 2314. Tampa, FL 33610.4115 I15ovthc Tn F�ir1e75P� Ivinher is xpeciffed, the design values are those effective 06 j�01/2013 by ALSC Job Truss Truss Type Qty Ply Gingras Residence Tfi375428 27052► a DO1G Roof Special Girder 1 1 Job Reference o tiona East Coast Truss, Fort Pierce, FL. 34946 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-74, 2-3=-74, 3-4=-74, 7-11=-20 Concentrated Loads (lb) Vert: 2=132(F) 6=-27(F) 5=-20(F) 14=71(F) 15=31(F) 7.520 s Apr 22 2014 M(Tek Industries, Inc, Thu Jun 19 13:13:44 2014 Page 2 I D:p7QmlfchPBBmXvB BT2NUhcz4kwS-ouJNyVBQCZclaBs42RNBKHxlP4LYLDO3SRkCh2z4jcr WARNIM3 - Venff desgn pammewn and READ M17ES M1174TSAW It(L1 Wrl) MIUW REFEREKE PASC MII-7473 mr. I fd9/20IJkMMME Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responslbillity of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Sgfety Information 7vapable from Jiuss Plate Institute, 781 N. Lee Street. Suite 312, Alexandria, VA 2314 1 SoutheYnRirtelSp}lumberisspetified,thedoltavaluesaret:hoseeff rt}rea6 IM13byJ'M M!Tek' 6904 Parke East Blvd. Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence T6375429 27052o, D02 Roof Special Girder 1 1 Job efere ce o tional East Coast Truss, Fort Pierce, FL. 34946 4-2-2 3.00 12 3x4 = 4x4 = LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr NO Code FBC2010rrP12007 CSI. TC 0.36 BC 0.47 WB 0.04 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 SLIDER Right 2x4 SP No.3 3-1-1 REACTIONS. (lb/size) 1=502/0-8-0, 4=340/0-9-2 Max Horz 1=27(LC 28) Max Uplift l=-129(LC 4), 4=-96(LC 4) Max Grav 1=504(LC 21), 4=348(LC 21) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=745/199, 2-16=-694/198, 3-16=-695/194, 3-4=-3751133 BOT CHORD 1-6=-152/686, 1-5=-179/686, 5-17=-177/690, 4-17=-177/690 7.520 s Apr 22 2014 MiTeK Industries, Inc. TnU Jun 19 13:13:45 ZU14 Page 1 ID:p7Qm IfchP88mXvB BT2NUhcz4kwS-G4tl9rC2ztk9CLRGb6uQtUU7_Ubk4gxCh5UIDUz4jcq l o-6.10 6-4-8 Scale=1:17.3 1.37112 DEFL. In (loc) I/defl L/d Vert(LL) -0.03 5-14 >999 240 Vert(TL) -0.09 5-14 >999 180 Horz(TL) 0.00 4 n/a n/a PLATES GRIP MT20' 2441190 Weight: 38 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installatione NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional);, cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 ♦j1I I I 111111111.f 3) Plates checked for a plus or minus 0 degree rotation about Its center. ,♦ S A-I� 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ♦♦♦ ��, • ... 'q�e �I� 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will C E NS •• qA ��� fit between the bottom chord and any other members. ��♦,`�••• V� 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 4 except Qt=lb) 1=129. ` 39380 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used In the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 49 lb down and 64 lb up at 64-6, and 21 lb down and 66 lb up at 8-7-6 on top chord, and 7 lb down and 25 lb up at 6-4-6, and 9 lb down and 74 lb up at 8-7-6 on botton : � x chord. The design/selection of such connection device(s) is the responsibility of others. (V 9) in the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). O •,• ATE LOAD CASE(S) Standard �i�Fs; ••. R �•, `tom ♦♦� 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 �j tS Uniform LoadVert:s `2In74, 2-4=-74, 6710=-20 '��, r� N A� �% Concentrated Loads (lb) Vert: 13=66(F) 14=47(F) 16=22(F) 17=15(F)' FL Cert. 6634 7 June 19,2014 ®WARNrhG-Yerifrdesign pan. mewrs and RFAD h07ESGNVUSAND HaUDED MITEXMFEREht£PAGE 1411-7473 rer. 1/t9120IdVEF0 M f• Design valid for use onlywith MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parametersand proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the MiTek' fabrication, Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. IfSouthemPine�SP�lumberisspecified,thedesigonvaluesarethaseaifectiveO6 0112013byAtSC Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence T6375430 27052 • � 003 Roof Special 1 1 Job efe a ce o tiona Fast coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:45 2014 Page 1 I D:p?Qm IfchP88mXvBBT2NUhcz4kwS-G4tl9rC2zlkgCLRGb8uQtUU?BUey4e7Ch5UIDUz4jcq i 5-4-13 8-10-5 5-4-13 3-5-8 Scale = 1:16.7 4x4 = 1.37 [12.. 3.00 2x4 II LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.35 Vert(LL) -0.01 5 >999 240 MT20. 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.27 Vert(TL) -0.03 5 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.16 Horz(TL) 0.00 4 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 34 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=478/0-8-0, 4=341/0-7-4 Max Horz 1=90(LC 7) Max Uplift 1=-119(LC 4), 4=-52(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-524/106, 2-3=-470/110, 3-4=-299/56 BOT CHORD 1-6=-51/462, 1-5=-111/462 WEBS 3-5=-82/411 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=0ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 `t%111 111 111111,1� plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. ��� S A. 4) This truss has been designed for 10.0 bottom live load loads. 0 •'� ��� a N`S a psf chord nonconcurrent with any other'live 5) • This truss has been designed for live load 20.Opsf the bottom in 3-6-0 tall by 2-0-0 vC•E �1�♦ �� F�'q�i ♦♦ a of on chord all areas where a rectangle wide will ��,�� fit between the bottom chord and any other members. 6 Provide bearing `1 3 938 mechanical connection (by others of truss to late capable of withstanding 100 lb uplift atjoint(s) 4 except t-Ib 1=119. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. • T E : �U ;p. ,c ` C? . '�, N A` �0 - ��•. II FL Cert. 6634 June 19,2014 ®WARNIX,-Ve6frdesr.7a parameters-d READ NMSONTNISAND Irr UDEDNITEKREFEREhCEPAGENII-N723m. 1119/2014DEfMME Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPiI Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information gva able from Truss Plate In tltute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. it5outhemPrrre`fiP furnherisspecifie the design values are theseeffestiv 461Q1/2013byALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty , Ply. Gingras Residence T6375431 2705R • D04 Roof Special 1 1 Job e e e ce o tionai East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITeK Intlustnes, Inc. Tnu Jun 19 13:13:46 2014 Naga 1 ID: p?QmlfchP8BmXvBBT2N Uhcz4kwS-kHR7NBCgkBtOpVOT9sPfPi19_u?cp5jLwID Ilxz4jcp 6-7-7 , 7-2-0 , 6-7-7 0-6-9 1.37 112 4x6 = 2x4 I 3 3x4 = 4 7-1-11 7- 0 1-a0 a40 5.9.11 0- 5 Plate Offsets (X Y)-- rl •0-7-0 0-0-81 11.0-1-4 Edoel r2:0-3-0 0-0-111 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.41 TCDL 17.0 Lumber Increase 1.25 BC 0.24 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=419/0-8-0, 4=241/0-7-4 Max Horz 1=137(LC 7) Max Uplift 1 =-1 14(LG 4). 4=-65(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4=-379/181 Scale=1:15.1 DEFL. in (loc) I/dell L/d PLATES GRIP Vert(LL) -0.03 4-8 >999 240 MT20 244/190 Vert(TL) -0.07 4-8 >999 180 Horz(TL). 0.00 4 n/a n/a Weight: 26 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 tic puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. ,`1t,1� �11I��� 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. �% S A. 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,���,...... A�e fit between the bottom chord and any other members. O�P `� ,• •� G E !S+ •• q�1�i� 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at jbint(s) 4 except Qt=lb) ,� ,` ; ' V _ •.��, .` 0 39380 S � Fir Z • ; 4U ATE.. ,O N A, " %� 1=114. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. FL Cert. 6634 June 19,2014 ®WARNIMN.rifydesign paramemn sadRM fM7ESON7?ASdNDlHaUDED MITEKREFEREME PAGE Mll-1413 rew 11t9120I WOMWE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. �' Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity, of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication. quality control, storage, delivery, erection and bracing. consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information vai able from Truss Plate Institute, 78114. Lee Street, Suite 312, Alexandria, VA 2314 It SouthernPine�SPlumbertsspecI ied,thedesig values are thoseeffective06I01JI013byALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375432 27052 • • -EJ1C Jack -Open 1 1 Job a ere ce o to al East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:46 2014 Page 1 ID:p?QmlfchP88mXvBBT2NUhcz4kwS-kHR7NBCgkBtOpVOT9sPfPi1 E3u1kp6pLwlDllxz4jcp 1-8.0 1-8-0 Scale = 1:6.5 o S b 1-7.10 1- o 1-7-10 0- 6 Plate Offsets (X Y)-- 11:0-7-0,0-0-81 11:0-1-4 Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL . 17.0 Lumber Increase 1.25 BC 0.10 Vert(TL) -0.00 4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00, 2 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 5 to FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-8-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.. MITek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation id REACTIONS. (lb/size) 1=220/0-7-10, 3=-46/Mechanical, 2=-17/Mechanical Max Horz 1=21(LC 4) Max Uplift 1=-178(LC 4), 3=-46(LC 1), 2=-19(LC 3) Max Grav 1=220(LC 1), 3=27(LC 4), 2=17(LC 4) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=1.32mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will `,'{{ fit between the bottom chord and any other members. �� S A, 5) Refer to girder(s) for truss to truss connections. ,�� OP'.......44 I� 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift atjoint(s) 3, 2 except Qt=1b) ���o C E ••. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was'used in the analysis and design of this truss. � K 39380,�- :fir ��0ATE ,�;� '4�,ss %, 1/1111{{ FL Cert. 6634 June 19,2014 ® WR!{NLhCi • Ver+fy �ra.sign pan, Drapers and READ A07F-S W RUS AM IM,VDED MtTFKRFEERF.FCt FAeEMi!-i4T3 rea 1/29/20140MON LASE Design valid for use any with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parametersand proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responslbillity, of the iTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safeh Information 4voi able f om jruss Plate In tifute, 781 N. Lee Street, Suite 312. Alexandria, VA 2314. Tampa, FL 33610 4115 ii5outlternpirTetSP (umber Is ecr#e ,the designvaluesarethosscifecthre46j01%1013tay'ALSC Job Truss Truss Type Qly Ply Gingras Residence T6376433 27052 . . -EJ2 Jack -Open 1 1 Job efere ce o lional east coast I russ, ton Pierce, FL. 34946 1-11-2 1-11-2 7,520 s Apr 22 2014 MIIeK Inaustnes, Inc. I nu Jun 1u 14;1:i:41 2U14 Pagel I D:p7Qm IfchP88mXvB BT2NUhcz4kwS-CT7WaXD IUU7tRfbflZwuyvZPkHN6YZ3V8PzslNz4jco Scale =1:6.9 i 1.8-0 1-11-2 1-8-0 Plate Offsets (X,Y)-- 11:0-7-0 0-0-81 11:0-1-4 Edoel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL. 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.00 4 >999 180 BCLL 0.0 Rep Stress Incr YES WS 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 6 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-11-2 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation e REACTIONS. (lb/size) 1=203/0-8-0, 3=-24/Mechanical, 2=3/Mechanical Max Horz 1=24(LC 4) Max Upliftl=-165(LC 4), 3=-25(LC 13), 2=-B(LC 5) Max Grav 1=203(LC 1), 3=7(LC 5), 2=13(LC 6) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES-' 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=4511; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will I 1111'r fit between the bottom chord and any other members. ��� P,CJ A• q ��� 5) Refer to girder(s) for truss to truss connections. �� •... • • 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2 except Qt=lb)........ G E N S+'• eie • ' V.. y '. 3938 ,_ Po OTE �� �l,,S,O N Ak- ,`, rM 111111 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. FL Cert. 6634 June 19,2014 I WARh1T7;•i •V xdfydes 4. p..—f n and READ AV7rSGN7V,1 AM ]AVI UDED M1TEK1ZEFEREhMFAGEM17.247.3 m. 1/29/29148C.1offil E Design valid for use only with Mirek connectors. This design Is based only upon parameters shown, and Is for an individual building component.• Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the �Te�• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding M fabrication, quality control, storage, delivery, erection and bracing. consult ANSI/TPII Quality Criteria, DSB•89 and BCSI Building Component 6904 Parke East Blvd. Safety Inlorma Ion 9vapable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 It Southern ine(SP`}lumberisspecified, the d-esiatvalues are thost_eifectiv�O6f01/2013byALC Job Truss Truss Type Qly Ply Gingras Residence T6375434 27052 ' •EJ2C Jack -Open 1 1 Job Reference o tional East coast I russ, FOR Nierce, FL. 34s46 fazu s Apr ce zuig mi 1 eK mausmas, inc. i nu uun 1L 13:i4;qt zulq rage d ID: p?Qm IfchP88mXvBBT2NUhcz4kwS-CT?WaXD IUU?tRfbflZwuyvZPVHMFYZ3V8Pzsl Nz4jco 2-1-7� 2-1-7 LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft L/d TCLL 20.0 Plates Increase 1.25 TC 0,10 Vert(LL) -0.00 4 >999 240 TCDL 17.0 Lumber Increase 1.25 BC 0.15 Vert(TL) -0.01 4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010ITP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=239/0-8-0, 2=8/Mechanical, 3=-54/Mechanical Max Horz 1=25(LC 4) Max Upliftl=-58(LC 4), 2=-11(LC 4), 3=-54(LC 1) Max Grav 1=239(LC 1), 2=9(LC 13), 3=15(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown, Scale =1:7.1 PLATES GRIP MT20 244/190 Weight: 7 lb FT = 0% BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-7 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installationguide. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0,18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 - 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,,111 1111�/��, fit between the bottom chord and any other members. �� PCj A, qt pol 5) Refer to girder(s) for truss to truss connections. ��,. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 1, 2, 3. �� �0 ,• G E N S+ �• �� ♦♦♦ 7) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. `��,� V ,_...-.<��•�•, -lam, j •• ATE Al WANIPM Veni7y r7esi.,yn pnnmetmrs y fRF.ADA07E9GNTri7S VR1 fhY7.ilIJFfI MITEKRF.'FERf1M'f'R6E Ali7•Tg7.3 n=.a 1129/201403''GMM.. Design valid for use only with M7ek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component S fety Informs Ion 44vagqable from jruss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. i?5o nmla;i7le{SFylumberisspecified,thedestghvatuesarethlsse.etfectiveCtS of%zwbyALSC FL Cert. 6634 7 June 19,2014 —p. MiTe®k' 6904 Parke East Blvd. Tampa, FL 33610.4115 Jab Truss Truss Type Qty Ply Gingras Residence T6376435 �Job•Rsference 27059 s -EJ3 Jack -Open 1 1 (optional) East Coast Truss, Fort Pierce, FL. 34946 2-8-0 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:48 2014 Page 1 I D:p?QmlfchP88mXvBBT2NUhcz4kwS-hfYuosExFo7k3o9rHGR7U76Zphhm HOJeN3iPgpz4jcn Scale =1:7.8 Plate Offsets (X,Y)-- f1:0-7-0 0-0-81, f1:0-14Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.13 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase. 1.25 BC 0.13 Vert(TL) -0.01 4 >999 180 BCLL 0.0 Rep Stress incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 8 lb FT = 0% LUMBER- EIRACING- TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-8-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MITek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Iligigilijign gulde, REACTIONS. (lb/size) 1=229/0-8-0, 2=34/Mechanical, 3=-18/Mechanical Max Horz 1=32(LC 4) Max Uplift I =-56(LC 4), 2=-20(LC 4), 3=-18(LC 1) Max Grav 1=229(LC 1), 2=34(LC 13), 3=9(LC 4) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will `�/���' fit between the bottom chord and any other members. � 5) Refer to girder(s) for truss to truss connections. *.� �... • • • �dj �j 0 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 1, 2, 3. `♦♦�,•'� G E•N S'• '9 �r� 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ♦� ,� V F��•,.i40 w *: N-6 39380 T E --^ 44/ s s /O N Atill ` E ;�� FL Cert. 6634 June 19,2014 ®WARNIM READ M715SON'RUSANJ fhY].ttDEO M!R?CREfFRF.MS A4GEMI!•T47;7 ie.R If29JT(/idL+FJC)AEWE Design valid for use only with M11ek connectors. This design Is based only upon parameters shown, and 1s for an Individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the tVI iTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. S fety I formation gva able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, A 2314 Tampa, FL 33610.4115 1 Sout�lernfxtne45P1tumberrsspeciiied>thedesignvaluesarethoseeffectaiiea /01f1U13byAILSC Job Truss Truss Type Qty Ply Gingras Residence T6375436 27052. . -EJ3C Jack -Open 1 1 Job Reference o ions tasl coast -truss, Fort Pierce, FL, 44946 3.1.12 3.1.12 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.17 TCDL 17.0 Lumber Increase 1.25 BC 0.13 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=240/0-8-0, 2=52/Mechanical, 3=-3/Mechanical Max Horz 1=38(LC 4) Max Uplift 1=-59(LC 4), 2=-28(LC 4), 3=-3(LC 1) Max Grav 1=240(LC 1), 2=52(LC 1), 3=17(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. /,oZU a Apr 22 ZU14 MI ex mausmes, mc. i nu Jun W Id:IJ:4o ZU14 raga 1 ID:p7Qm IfchP88mXvBBT2N Uhcz4kwS-hfYuosExFo7k3o9rHGR7U76ZGhirHOJeN3iPgpz4jcn Scale = 1:8.4 N a5 d DEFL. in (too) I/defl Ud PLATES GRIP Vert(L-) -0.00 4 >999 240 MT20 244/190 Vert(TL) -0.01 4 >999 180 Horz(TL) -0.00 2 n/a n/a Weight: 10 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MITek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installatione NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about Its center. 31 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed fore live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,,,,11 fit between the bottom chord and any other. members. `�% Prj A. 5) Refer to girder(s) for truss to truss connections. �� • • • • .., �e �j� 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. �� �� G E N S '• '9 �� 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. :��A� 39380 •'- -� LATE :•lU M OR ,���ss�4 ®WARNM-Vehflrtesigap ra—mrv,4a RFAb A07ESONVIFYAM JAMUDED MITFKREEERENCEPACENZI-T473—.Ij7.9120I+rUE3'ON ME Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responslbilllty of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Sale Informs on Ova able from Truss Pla a Institute, 781 N. Lee Street, Suite 312, Alexandra, Vq 2314. ifsouthern maiS 1.berisspecified,thedeftovaluesartdthoseef#ertive06��01f2013byRL3C FL Cert. 6634 June 19,2014 Mffek' 6004 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type City Ply Gingras Residence • T6375437 2705$ • -EJ4C Jack -Open 1 1 Jo b Re a ence o do al East Coast Truss, Fort Pierce, FL. 34946 2-8-5 7.520 S Apr 22 2014 MITeK industries, Inc. Thu Jun 19 13:13:49 Z014 Page 1 ID:p?QmlfchP88mXvBBT2NUhcz4kwS-9r6G?CFZ06Fbgyk2q_zM1KekX5100TYocjSzMGz4jcm Scale =1:7.8 1.0.0 1-4.0 2-8-5 1.0.0 0.40 1-4-5 Plate Offsets (X,Y)— f1:0-7-0 0-0-81 fl:0-1-4 Edoel LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.13 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.13 Vert(TL) -0.01 4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a ' n/a BCDL 10.0 Code FBC201 0/TP 12007 (Matrix-M) Weight: 8 lb FT = 0% LUMBER- BRACING - TOP CHORD. 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-8-5 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Ingtallatigo ggide. REACTIONS. (lb/size) 1=22910-8-0, 2=35/Mechanical, 3=-17/Mechanical Max Horz 1=33(LC 4) Max Upliftl=-56(LC 4), 2=21(1_C 4), 3=17(LC 1) . Max Grav 1=229(LC 1), 2=35(LC 13), 3=9(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. `*% • �e �j 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 1, 2, 3. "Semi • •. ,�� �0•. G E N • V ���•, 7) -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. :� ,t; ; + + ,. • O AT E e%fit N A` ��•. FL Cert. 6634 June 19,2014 ,&WARN7M9• Verifydes j­i,rr rmrs Bad READ M77r9Gf1T1IT5AND INCUIDED KrTEKREFEREMFPAGEMII-MJ3 m. I/i.4J201dDEFOMWE Design valid for use only with MTek connectors. This design Is based only upon parameters shown; and is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity, of the MiTek erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. safety Informs lon vo' able from jruss Plate In titute, 781 IJ. Lee SfreeL S01te 312, Alexandria, VA 2314. IfSouthern�rte7fip:lumberisspLcifier�, the design values are those efiettive46 0112018byAtSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375438 27052. • -EJ5 Jack -Open 2 1 Job Reference (optional) East Coast -rruss, Fort Pierce, FL. 34945 5-0.0 5-0-0 d 7.5'Lu a Apr zz "1u14 MI I eK inauslnes, inc. i nu jun 1e 16:1,:4a Lu14 rage 1 ID:p7QmlfchPBBmXvBBT2NUhcz4kwS-9r6G7CFZ06Fbgyk2q_zM1KegC5OmOTYocjSzMGz4jcm Scale=1:10.7 LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2010/TP12007 CSI. TC 0.41 BC 0.21 WB 0.00 (Matrix-M) DEFL. in Vert(LL) -0.01 Vert(TL) -0.01 Horz(TL) 0.00 (loc) I/defl Ud 3-7 >999 240 3-7 >999 180 2 n/a n/a PLATES GRIP MT20 244/190 Weight: 15 Ito FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly -applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation REACTIONS. (lb/size) 1=323/0-8-0, 2=113/Mechanical, 3=28/Mechanical Max Horz 1=61(LC 4) Max Uplift 1 =-80(LC 4), 2=-54(LC 4) Max Grav 1=323(LC 1), 2=113(LC 1), 3=58(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown, NOTES- 1) Wind: ASCE 7-10; Vult=.170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3,Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will %** 1rrrr1 , fit between the bottom chord and any other members. `�� PCj A, q 5) Refer to girder(s) for truss to truss connections.• • �e �i 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. ,�� � ,•'� G E N S • •• '9 ��i 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. �% ,r; 0 39380 -- ATE :emu/. '. 0 N AL E�C� %. rrnn�n��� FL Cent. 6634 June 19,2014 ®WARNIAG. edfrdesign Parametersand READ h07ESGN7Rr5AND1haUDED MINKREFERE&M PAGE N11-7473ma I/29/201daffaffLE Design valid for use only with MiTek connectors, This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity, of the WOW Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component fabrication, 6904 Parke East Blvd. Safety Information va able from Truss Plate Institute. 781 N. Lee Street. Suite 312, Alexandria, VA 2314. IfSvuthernP"ine�SP�lumherisspecified,thedesignvaluesarethoseeffective0b 01/2013byAtSC 'Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6376439 27052• y -EJSC Jack -Open � 1 1 , Job eference o do al East (;cast Truss, Fort Pierce, FL. 34946 3-8-11 7,520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:60 2014 Page 1 ID: p7Qm IfchP88mXvBBT2N Uhcz4kwS-d2geDYFBnPNS16JEOhUbaYBulVN5lwoxrNB Wuiz4jcl Scale = 1:9.1 Plate Offsets (X.Y)-- rl:0-7-0,0-0-81. 11:0-1-4 Edoel LOADING (psf) SPACING- 2-0-0 CS]. DEFL, in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.22 Vert(LL) 0.00 3-7 >999 240 MT20 244/190 TCDL 17,0 Lumber Increase 1,25 BC 0.14 Vert(TL) -0.00 4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 11 ib FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 3-8-11 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation REACTIONS. (lb/size) 1=262/0-B-0, 2=72/Mechanical, 3=9/Mechanical Max Harz 1=45(LC 4) Max Uplift 1=-213(LC 4), 2=-34(LC 4), 3=-41(LC 8) Max Grav 1=262(LC 1), 2=73(LC 13), 3=32(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; 13=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 311 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,`SSI I I I I ►f/,�� fit between the bottom chord and any other members. �� Cj A, 5) Refer to girder(s) for truss to truss connections. ��� �P.... • 'q f e �j 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3 except (jt=lb) �� �, E N S •• '9 �i� O 39380 ---� e�,;�sT� i A1111111 7) "Semi -rigid pitch breaks Including heels" Member end fixity model was used in the analysis and design of this truss. FL Cert. 6634 June 19,2014 ®WARNEN3•Verify desktop.m—ters and READ AWES GN7NIS AND Mrlb Eb MITEKREEEREh PAGE Mrl•7473 m a I/n/20fdaffof mE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown i��■ is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek• erector, Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding , fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va' able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria. VA 314 If Southern Pin e7SPrlurnlrertss7recified,thede5trgnvatuesarethosEefiective46 SjtO13byA1JC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375440 27052 • -EJ6C Jack -Open 1 1 Jo b e e e ce o do a East CoaSt Truss, Fort Pierce, FL. 34946 4-9-0 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:50 2014 Page 1 ID:p7QmlfchP88mXvB BT2NUhcz4kwS-d2geDYFBnPNS16JEOhUbaYBsdVMpiwoxrNBWuiz4jcl I 1-0.0 1-4.0 4-9.0 1 1-0.0 0-40 3-5-0 Plate Offsets (X Y)— 11:0-7-0 0-0-81.11:0-1-4 Edeel LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plates Increase 1,25 TC 0.37 TCDL 17.0 Lumber Increase 1.25 BC 0.22 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=311/0-8-0, 2=106/Mechanical, 3=25/Mechanical Max Horz 1=58(LC 4) Max Uplift 1 =-252(LC 4), 2=-51(LC 4), 3=-64(LC 8) Max Grav 1=311(LC 1), 2=106(LC 1), 3=53(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale=1:10.4 DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) 0.01 3-7 >999 240 MT20 244/190 Vert(TL) -0.01 3-7 >999 180 Horz(TL) -0.00 2 n/a n/a Weight: 14 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-9-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide willI I <<firl., fit between the bottom chord and any other members. `�� PcJ A• ,q ��� 5) Refer to girder(s) for truss to truss connections. �� •,. • • • �e �j .6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3 except (jt=lb) ,���0 ,•'� G != N S+'• '9A �i� 1=252. `� �' •••,�y i 0 39380 Mir - ATE • /0 N A- E�C� �. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. FL Cert. 6634 June 19,2014 ®WARNIMi -Verify design p...mewn aid RFAD A07ES W THIS AND IMIUDED MITFXREFERF&1W PAGE NII.7473 ra a 1/Z9120.rdDff(=WF- Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer, Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responslbillity of the NtiTek• ' erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. S lety Information vai able from Jruss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314 1�Sauthern tne7Sp�lumber lsspecifled, the design values artsthoseef#ectivae' 101/1413byAtSC Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence T6375441 27052 • -EJ7 Jack -Open 14 1 - Job Reference (optional) East Coast Truss, Fort Pierce, FL. 34946 7-D-0 /.ozu s Apr LL Lu14 MI I eK Inausuies, ma. 1 nu Jun la to; IJ:ou Gu Iq rdqu I ID:p?QmlfchP88mXvBBT2NUhcz4kwS-d2geDYFBnPNS16JEOhUbaYB) VlylwoxrNBWuiz4jcl LOADING (psfj SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.92 Vert(LL) -0.04 3-7 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.47 Vert(TL) -0.10 3-7 >855 18.0 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.01 2 n/a n/a BCDL 10.0 Code FBC20101TPI2007 (Matrix-M) Weight: 21. lb FT = O% LUMBER- BRACING- TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide, REACTIONS. (lb/size) 1=429/0-8-0, 2=173/Mechanical, 3=49/Mechanical Max Horz 1=86(LC 4) Max Uplift 1=-107(LC 4). 2=-81(LC 4) Max Grav 1=429(LC 1), 2=173(LC 1), 3=93(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-284/123 BOT CHORD 1-7=-143/333 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; 13=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ;'end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ,��-n P,CJ A• ,q ��j� 4) • This truss has been designed for a live load of 20,Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,�� �`Y` •,.. �e fit between the bottom chord and any other members. `e .•'� ii E N S ' • q�l�i� 5) Refer to girder(s) for truss to truss connections. �� ; • f_-_.,..F••'. [��,—!. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except Qt=lb) r 39 1=107. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ATE : 441 e .00 0 o A, O R 1 O P N,``�� &/0 N A� FL Cert. 6634 June 19,2014 ® WARMAKI -Verify design pammelva..d RrAD AMESGAr MISAN0 INaUDED MITWEEFERENM RAGE MII-7473 yea If29J201daEFOtIEUSE Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown ■�Yi Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibilllty of the WOWerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding . fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI7 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informa Ion va able from Truss Plate Institute. 781 14 Lee Street. Suite 312. Alexandria, VA 2314 IfSauthem ine�SP�lumlTerissp0cified,thedesignvaluesarethvseQtfective05 01/1013byAL5C .Tampa, FL 33610.4115 Job Truss Truss Type city Ply Gingras Residence T6375442 27052a� -EJ7C Jack -Open 1 1 Jo b e e ence o do al Casl Looasl i russ, port coerce, k-L. J4V46 5-0-6 I Ozu s Apr zz zul4 MI I ex,nuuslr us, Inc. I u Jun ,9 wA w:OI ,u 14 rage I ID:p?QmlfchP88mXvB BT2NUhcz4kwS-5EEOQuGpYjVJwGuQyP?g6lk_EvgNUN2431 x3R8z4jck Scale = 1:12.4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) 0.04 3-7 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.33 Vert(TL) -0.04 3-7 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010frPI2007 (Matrix-M) Weight: 18 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-9-6 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation REACTIONS. (lb/size) 1=364/0-8-0, 2=137/Mechanical, 3=37/Mechanical Max Horz 1=71(LC 4) Max Uplift 1 =-296(LC 4), 2=-67(LC 4), 3=-86(LC 4) Max Grav 1=364(LC 1), 2=137(LC 1), 3=72(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1,60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,,�r,l 11 JI,r1j# fit between the bottom chord and any other members. �% P`S A. 5) Refer to girder(s) for truss to truss connections. % • • ...... 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3 except Gt=lb) �� G E ' • �7,9 ice, 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. + �'3938 F �• :'. - ATE � ••� e •.• s `O N A` '� FL Cert. 6634 June 19,2014 ®WARMlKi-Veri7p design parnmebors ,nnd READ MITES GN 7TRS AND lNQUDED MITFKRff ERENCE PAGE. MIf•M73 m.r. I/19/7.0I18EFORENSE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown ■ Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the MOWerector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding tobdcation, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 69D4 Parke East Blvd. Safety Informattion vai able from jruss Plate Institute, 781 N, Lee Street, Suite 312, Alexandria, VA 2314. if,Southern R'ine�,Sp lumber lsspecified,thede5ignvaluesarethose EifectisTe05 01/2013byALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375443 270520 t -EJ8C Jack -Open 1 1 Job Reference (options[ East Coast Truss, Fort Pierce, FL. 34946 6-0-11 d N 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:51 2014 Page 1 I D:p7QmlfchPBBmXvBBT2N Uhcz4kwS-5EEOQuGpYjVJwGuQyP7g61kvjveTUN2431 x3R8z4jck Scale=1:14.0 1-ao 1•a-o 6-s•1 __ 1-ao 0.4-0 Mill Plate Offsets (X Y)-- I1:0-7-0 0-0-81 11:0-1-4 Edoel LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL) 0.09 3-7 >881 240 MT20 244/190 TCDL 17.0 Lumber Increase . 1.25 BC 0.45 Vert(TL) -0.08 3-7 >958 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 21 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc,purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation REACTIONS. (lb/size) 1=419/0-8-0, 2=168/Mechanical, 3=47/Mechanical Max Horz 1=84(LC 4) Max Uplift 1=-341 (LC 4), 2=-82(LC 4), 3=-107(LC 4) Max Grav 1=419(LC 1), 2=168(LC 1), 3=90(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-247/258 BOT CHORD 1-7=-291/290 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. �ry11 1I /I�Ij* m 3) This truss has been designed for a 10.0 psf botto.chord live load nonconcurrent with any other live loads.PS 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord. In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will A. q • • �e �j fit between the bottom chord and any other members. ,�� �`V` •.. ,� .• `� G E N,9 •• 5) Refer to girder(s) for truss to truss connections. 100 lb 2 1=341 ♦ ,` •• V��+,��! 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding uplift at joint(s) except Qt=lb) 0 39380- �- 3=107. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. '.: ATE . 441 O.�s,c� 0 R , O P Q�,\_,�. �.% FL Cert. 6634 June 19,2014 ,&wARNmr,-Verify design rarsnreten unJ AFi10 AO7£SCOM16AND IACIMED MITWR£fEREACE PAGEMfI.7473 rea I12912015NfFaULM Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown ■■��YY Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsiblllity of the MiTek erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabdcation, quality control, storage, delivery, erection and bracing. consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va' able from Truss Plate Institute. 781 N. Lee Street, Suite 312, Alexandria, VA y2314. ItSauthemPine7SP lumberisspecified,thedesignvaluesarethoseeffective45f 112.013byALSC Tampa, FL 33610-4115 Job Truss Truss Type . City Ply Gingras Residence T6375444 27052• 3•EJ9C Roof Special 1 1 Job Reference (optional tast Coast i ruse, ron werce, t-L. 3494b r.ozu s Apr zz zu14 mi i eK mausmes, inc. i nu dun is w:is:oz zuiv rage i ID: p?Qm ifchP86mXVB BT2NUhcz4kW S-ZQoOdEHRJ 1 dAXQTdW6W3fzGAkll eDosElhgdzaz4jcj 7-9-4 7- -1 7-9-4 0• 13 Scale=1:15.7 1•a07-10-1 1-a0 0.4.0 6-2-7 b-3-10 Plate Offsets (X Y)-- 0:0-7-0 0-0-81 11:0-1-4 Edgel 15.0-2-8 0-0-81 LOADING(psf) SPACING. 2-0.0 CSI. DEFL. In floc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.46 Vert(LL) 0.06 5-9 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.06 5-9 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.16 Horz(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC2010rrP12007 (Matrix-M) Weight: 26 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installatione REACTIONS. All bearings Mechanical except (jt=length) 1=0-8-0, 5=0-4-2. (lb) - Max Horz 1=96(LC 4) Max Uplift All uplift 100lb or less atjoirl except 1=-308(LC 4), 3=-551(LC 1), 4=-312(LC 3), 5=-941(LC 4) Max Grav All reactions 250 lb or less atjoint(s) except 1=388(LC 1), 3=277(LC 4), 4=385(LC 4), 5=1061(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-5=-818/406 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about Its center. This truss has beendesignedpsf bottom chord l li 4) the bottom chord in all areas wherelive This t uss has been dee signed forr a load of 20.Opsf on arectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. ��% S • • • • �e �i 5) Refer to girder(s) for truss to truss connections. 551. Ib 3, ♦�%% O \O� , • (, E N S •. q ��� F �•,�✓ 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 308 lb uplift atjoint 1, uplift at joint 312 lb uplift at joint 4 and 941 lb uplift at joint 5. `♦♦� ,•'•�.� _ f 938 7) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. ` Qom! Xx .• E—: ... AT d • 4 Q • q1 ss�ONA1-E;�C�%. fill is FL Cert. 6634 ::1 June 19,2014 A WARNIM •Verify design Pammew. and READ PATES UK 7111SAM 1MIUDE0MITEKREEERE,4CF PAGE 0111.2423 ms. I1t91201dB1 DUME- Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Nil' � Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria,.DSB-B9 and BCSI Building Component 6904 Parke East Blvd. Safety Inlormatlgn vat able from Jruss Plate Institute, 781 N. Lee Street, Sulie 312, Alexandria. VA 2314. 1f5authelnPtne7SP�lumberissgecified,thedesianvaluesarethaseeffective46 01/2013byAISC Tampa, FL 33610-4115 Job ' Truss Truss Type Qty Ply Gingras Residence T6375445 2705Z 1 FG01 FLOOR GIRDER 1 3 Job Reference (optional) easi wasi i russ, ron coerce, rL. sae40 1-10-2� 118-6� 1x4 II 3x8 = 1x4 II 13x8 = 24 2 25 3 26 4 r.ozu s Apr zz zu is mu en mausmes, Inc. i nu uun ro ia: ie:oo cu w rays i ID: p7Qm IfchP88mXvB BT2NUhcz4kwS-1 dMnral34K119a2p3g1 IBApDM iEy7tNXLQAVI z4jci 1-10-2� Scale = 1:35.2 3x8 = 1x4 II 5x14 M18SHS = 27 5 28 6 29 7 30 1x4 II 3x8 = 1x4 II 3x8 = 8 31 9 32 10 33 11 23 22 21 20 19 18 17 16 15 14 13 12 44 II 4x10 = 2x4 I I 3x8 = 6x8 M18SHS = 3x8 = 2x4 I I 3x8 = 2x4 I I 4x10 = 4x4 II 2x4 II 8-4-144 1.4-112 4-14 I 47 11 84 18-14--12511. 22459.8-8 1---14 1.14 11-1-11-11-1 -2-5-6 4 141=3 1-14 4 Plate Offsets (X Y)-- (7.0-5-12 0-3-01 f18:0-3-10 0-0-01 LOADING (psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.88 Vert(LL) -0.58 17 >424 360 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.90 Vert(TL) -0.90 17 >272 240 M18SHS 244/190 BCLL 0.0 Rep Stress [nor NO WB 0.68 Horz(TL) 0.09 12 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 351 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 'Except* TOP CHORD Structural wood sheathing directly applied or 2-2-10 oc purlins, except 7-11: 2x4 SP No.2 end verticals. BOT CHORD 2x6 SP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 *Except* 1-23,11-12: 2x6 SP No.2, 1-22,11-13: 2x4 SP No.2 REACTIONS. (lb/size) 23=3852/Mechanical, 12=3852/Mechanical FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-23=-3266/0, 11-12=-3222/0, 1-24=-7441/0, 2-24=-7441/0, 2-25=-7441/0, 3-25=-7441/0, 3-26=-17125/0, 4-26=-17125/0, 4-27=-17125/0, 5-27=-17125/0, 5-28=-20705/0, 6-28=-20705/0, 6-29=-20705/0, 7-29=2070510, 7-30=17050/0, 8-30=-17050/0, 8-31=-17050/0, 9-31=-17050/0, 9-32=-7359/0, 10.32=-7359/0, 10-33=-7359/0,11-33=-7359/0 BOT CHORD 22-23=0/773, 21-22=0/13782, 20-21=0/13782, 19-20=0/20676, 18-19=0/20676, 17-18=0/20676, 16-17=0/20766, 15-16=0/21020, 14-15=0/13820, 13-14=0/13820, 12-13=01767 WEBS 2-22=-529/0, 3-21=0/566, 4-20=-595/0, 5-19=0/693, 6-17=-674/0, 7-16=0/684, 320=0/3712, 5/0 5-20=3942/097-15= 4283/0, 9 153585, 9?13= 76173 0?11-130/7181 AID NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: �� ��•' G E N ;�A�.••�,� Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. ; • •• : 3 Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. * 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to pIC - connections have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated. 3) All plates are MT20 plates unless otherwise indicated.b E �U 4) Plates checked for a plus or minus 0 degree rotation about its center. :• I HT Q 4 1 5) Refer to girder(s) for truss to truss connections, 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. i� T • T Q` �� ••. 0 R \ �.•� \ ........be 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to attached to s at their outer ends or restrained by other means. 8) Hanger(s) or other iconnection device(s) shall be provided sufficient to support concentrated load(s) 285 lb down at 2-0-0, 285 lb down at 18-9-8, 365 lb down at 4-0-0, 365 lb down at 16-9-8, 429 lb down at 6-0-0, 429 lb down at 8-0-0, 429 ib down at 14-9-8, 429 lb down at 12-9-8, and 429 lb down at 10-0-0, and 429 lb down at 10-9-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. FL Cert. 6634 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. June 19,2014 6&I#A,g W(UeSpandard ®l1'ARNIAG -Verify design paramemn ,cnd I1Ei1D tA7ESGN 7T$SAND I=UDED MITEKREEEREACE PAGE MII-7473.. I119/20I4aFFOREIAE Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer -Bracing shown ■ Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity, of the MiTek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information Qvai�able from Truss Plate Institute, 781 N, Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 lf5nuthemPinettSP lumberisspecdied,thedeAgnvalues are thoseeffectri2e0fi 1%2013byAtSC Job Truss Truss Type Qty Ply Gingras Residence T6375445 27052 1 FG01 FLOOR GIRDER 1 q 3 Jo ee ce o t'o al East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MTek Industries, Inc. Thu Jun 19 13:13:53 2014 Page 2 ID: p7Qm IfchP88mXvB BT2NUhcz4kwS-1 dMnra134K119a2p3g1 IBApDMiEy7tNXLQAVI z4jci LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 12-23=-7, 1-11=-182(F=-115) Concentrated Loads (lb) Vert:24=-285(F) 25=-365(F) 26=-429(F) 27=-429(F) 28=-429(F) 29=-429(F) 30=-429(F) 31=-429(f) 32=-365(F) 33=-285(F) ®WARMIMi NedfT design parumaoen aaJ RFAD M17ESGT77NTSAND YaUDED MITEKREFEREMX PAGE M11-1473 — I12.9120I4MONEWE Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown ■■So�• Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responslbillity, of the N9iTek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. IlSouthemPine{SP lum erisspeltilfieditUiede�s riirutiiesareth3os> eli#eiuve05/03/2013byATSC Tampa, FL336104115 Job Truss Truss Type City Ply Gingras Residence T8375446 27051 1 FG02 Floor Girder 1 n 'o L Job Reference o al r nsr was, , russ, rwx rim-, rL. soygo 0.3.8 1-10-0 i 1-3-0 i 1.4-12 0-9-12 3x4 = 1x4 II 3x4 = 2 3 4 22 21 23 20 10x10 = 46 = Special 10x10 = r.acu s npr u cu w rvm nn muwwoa, mu. r royo , I D:p9QmlfchP88mXvBBT2NUhcz4kwS-Vpw92wlhrettnjd7dXYXkOMTm6eLhazXl_gk1 Tz4jch P:L1_0i i 2-0-0 I�� 3x4 = 1x4 II 5 6 19 18 3x4' = 3x4 = 1x4 II 3x4 = 3x4 = 7 8 9 P 10 17 16 3x4 = 3x4 = 1-101-10-0�� 0� ' Stelg 11:35.3 3x4 = 3x4 = 5x5 = 10 11 12 0 15 14 13 3x4 = 3x4 = 1x4 II 0.1-8 104-10 • 114-10 0- 2-1-8 4-7-8 7-1-8 9-4-10 9- 1-0-2 13-7-12 18-1-12 18.7-12 20-7-12 20 d 0- - 2-0-0 2,_0 2-8-0 2-3-2 —21 -0 0-7, 2-3-2 2-6-0 2-6.0 2-0-0 0- $ 0.1-8 0-7-8 0-4-8 Plate Offsets (X Y)— rl2.0-2-4 0-2-121 i20:0-4-12 Edgel 122:Edae 0-2-81 LOADING (psf) SPACING. 1-4-0 CSI. DEFL, in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase . 1.00 TC 0.68 Vert(LL) -0.37 18 >668 360 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.63 Vert(TL) -0.58 18 >422 240 BCLL 0.0 Rep Stress Incr NO WB 0.69 Horz(TL) 0.06 13 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 209 Ib FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-5 oc purlins. BOT CHORD 2x8 SP SS *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 13-20: 2x4 SP 2850F 1.8E WEBS 2x4 SP No.3 *Except* 1-21: 2x4 SP No.2 REACTIONS. (lb/size) 22=2733/Mechanical, 13=1 121 /Mechanical FORCES. (lb) -Max, Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-22=-2149/0, 12-13=-1060/0, 1-2=-4798/0, 2-3=-7950/0, 3-4=-7941/0, 4-5=-7923/0, 5-6=7108/0, 6-7=-7108/0, 7-8=-7108/0, 8-9=7108/0, 9-10=-5570/0, 10-11=-4013/0, 11-12=-1871/0 BOT CHORD 21-22=01315, 21-23=0/6614, 20-23=0/6475, 19-20=0/8038, 18-19=0/7642, 17-18=017108, 16-17=0/6396, 15-16=0/4898, 14-15=0/3055 WEBS 6-18=01514, 7-17=-701/0, 1-21=0/4912, 2-21=-214210, 2-20=0/1751, 4-19=-298/0, 5-19=0/574, 5-1 8=-1 120/0, 12-14=0/2018, 11-14=-154110, 11-15=0/1247, 10-15=1152/0, 10-16=0/876, 9-16=-1111/0, 9-17=0/1401 NOTES- ,0 S A,ti11111111/��,I 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: , Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. ♦♦ P, ♦ �•.••..... e Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-3-0 oc, 2x4 - 1 row at 0-9-0 oc. �� O G E N • •• �� Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. ♦♦,`� V 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply: 938 connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) Refer to girder(s) for truss to truss connections. : rp • t� ► 6) Provide metal plate or equivalent at bearing(s) 22 to support reaction shown. . 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. %.• ATE 8) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to 0T •.• A,Q. •: ♦� be attached to walls at their outer ends or restrained by other.means. i� . 4 Q Fj \ �,•' �� ♦♦♦ 9) CAUTION, Do not erect truss backwards. ,* lss • .. • .... ♦♦ 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2352 lb down at 3-4-6 on bottom ;///Q N M— ��♦ chord. The design/selection of such connection device(s) is the responsibility of others. �"i f 1111111"k 11) Waming: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD.CASE(S) Standard FL Cert. 6634 June 19,2014 Continued'on a e 2 ® WARNIMT Nedfgdesl0a pa eWn and READ AVVS OF/MISAND INaUDED MITEKREEERE&OF PAGE k13.7473 re•3/Z4/30Id8Et'GREtAE ® Design valid for use only with Mffek connectors. This design is based only upon parameters shown. and is for an Individual building component.®�• Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown ■�Y■ is for lateral support of Individual web members only. Additional temporary bracing fdInsure stability during construction is the responsibillity, of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 69D4 Parke East Blvd. Safe Informa Ion va able from russ Plate Institute, 781 N. Lee Street,'Suite'312, Alwandda, VA 2314. 1fSouthern ine�SP lumberis�ecified,thedesignvaluesarethoseettectiveQ6 Q1J2013byALSC Tama FL 33610-4115 p' Job Truss Truss Type Qty Ply Gingras Residence T6375446 27052 ., -• FG02 Floor Girder 1 2 b eference o lional tasl Goasl I ruse, Fon Fierce, FL. 34945 LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 13-22=-7, 1-12=-67 Concentrated Loads (lb) Vert: 23=-2352(F) 7.520 S Apr ZZ Zu14 MI I eK Inaustnes, Inc. I nu Jun 19 13:13:54 2u14 Fage Z ID: p7Qm IfchP88mXvBBT2NUhcz4kwS-Vpw92wlhrettnjd7dXYXkOMTm6eLhazXl_9k1 Tz4jch ®W,UtNING •Veritt des�n pnrnrreters Jnd READ fA7ES CN7tirSAND lt1F].VDED MITEKRf'EEREMf"hAGE NJJ-7473 ma J/29/201Q!!!f'0NEIJSE Design valid for use only with Wek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the M iTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Sale 1 Iormatlon gvagable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, Vqq 2314. Tama FL 33610-4115 IfSaut�lernPine SP lumberisspetiled,thedesignvaluesarethoseeffective05�01/2013byALSC p' Job Truss Truss Type Qty Ply Gingras Residence T6375447 2705,.A. '1 FG03 Floor Girder 1 Job Reference (optional East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MiTek Industries, Inc. Thu Jun 19 13:13:65 2014 Page 1 ID:p?Qm IfchP88mXvBBT2NUhcz4kwS-z?UXGGJKcy?kOtC BBF3m GbucdWzyQ1 Vg_evHavz4jcg 1-8-14 1-7-2 1-7-2 . 1.7-2 , 1-10.10 , 1-8-6 1-8-6 8.6 1-10-2 Scale = 1:36.3 Special Special Special Special Special Special Special Special Special Special Special Special Special Special Special Special Special Special Special 1x4 II 3x4 = 1x4 I 5x10 = 2x4 II 5x10 = 1x4 II 3x4 = 1x4 II ' 3x8 = 13x8 = 2 3 4 Special 5 Special 6 25 - 7 26 8 27 9 28 10 29 11 3x4 11 3x10 M18SHS = 4x6 = 3x10 = 2x4 II 4x6 = 3x10 = 2x4 II 3x10 = 4x6 II 3x10 M18SHS = 3x4 II Special 2- 2 4-2.11 6-1-5 7-11-14 9-10-8 1 1 4. 12-4-6 44-5 16.4-3 18-4-2 20.9.8 2.4.2 1.10-10 1-10-10 1.10-10 1-10-10 0• - 2 2-3-2 1-11-14 •1-11-14 1-11-14 2-5.8 LOADING (psf) SPACING- 1-4-0 CSI. TCLL 40.0 Plates Increase 1.00 TC 0.80 TCDL 10.0 Lumber Increase 1.00 BC 0.61 BCLL 0.0 Rep Stress Incr NO WB 0.67 BCDL 5.0 Code FBC2010/TP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP SS 'Except' 21-22,13-14: 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* 1-23,11-12,6-17: 2x6 SP No.2 1-22,3-20,5-20,5-17,7-17,7-15,9-15,11-13: 2x4 SP No.2 REACTIONS. (Ib/size) 23=2310/Mechanical, 12=1232/Mechanical, 17=592110-6-0 Max Grav23=2502(LC 3), 12=1375(LC 4), 17=5921(LC 1) DEFL. in (loc) I/deft L/d Vert(LL) -0.09 20-21 >999 360 Vert(TL) -0.12 20-21 >955 240 Horz(TL) 0.01 17 n/a n/a 0 Id PLATES GRIP MT20 244/190 M18SHS 244/190 Weight: 234 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-11-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-23=;-2462/0, 11-12=-1293/0, 1-2=-4699/0, 2-3=-4699/0, 34=4173/0, 4-5=-4173/0, 5-6=0/4677, 6-25=0/4677, 7-25=0/4677, 7-26=-2447/924, 8-26=-2447/924, 8-27=-2447/924, 9-27=-2447/924, 9-28=-2702/56, 10-28=-2702/56, 10-29=-2702/56, 11-29=-2702/56 BOT CHORD 22-23=0/345, 22-24=0/4699, 21-24=0/4699, 20-21=0/4699, 19-20=-1489/1029, 18-19=-1489/1029, 17-18=-1489/1029, 16-17=-2236/0, 15-16=-2328/0, 14-15=-56/2702, 13-14=-56/2702, 12-13=0/251 WEBS 6-17=-1326/0, 2-22=-489/0, 3-21=-226/614, 4-20=-839/0, 5-19=-555/0, 7-16=318/0, ,�11111111,�� 5-17=4605/097-17—3832/0, 7-15=013242, 9-15—1153180 0, 11-13 190=0/4020, 13/2669 •�''• ,,���, E N NOTES- .••\,\Ci SF. •''9j%— 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows; 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-5-0 oc. ,♦��` • r, N O 3 93 Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc, 2x4 - 1 row at 0-6-0 oc. Webs connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-O.oc. 2) All loads are considered equally applied to all plies, except If noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to plyr ri:c connections have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated. 3) Unbalanced floor live loads have been considered for this design. tG/ ;�� .. '- ATE 44/ 4) All plates are MT.20 plates unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. � ,�'.• iC` ii, < p R 1 O P •' N ♦♦♦ �'' 6) Refer to girder(s) for1russ to truss connections. s and design of this truss. 7) "Semi tchbreaks end ixity model was used in the rat �j� lss • • • • •' �� �♦ '��I -rigid 8) Recommend 12x6 t ongbacks,nonhedge, spaced Of 0-0 oc and fastened to each trusslw with 3-1 Old (0.131" X 3') nails. Strongbacks to tO f l l E t��♦ be attached to walls at their outer ends or restrained by other means. 9) CAUTION, Do not erect truss backwards. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 285 lb down at 0-2-12, 285 lb FL Cert. 6634 down at 18-9-8. 365 lb down at 164-6, 365 lb down at 4-0-0. 429 lb down at 6-0-0, 429 lb down at 8-0-0, 429 lb down at 10-0-0, 429 lb down at 10-9-8, and 429 lb down at 12-9-8, and 429 lb down at 14-9-8 on top chord, and 1759 lb down at 3-4-8 on bottom June 19,2014 ContSriM9.0�%ggslgn/selection of such connection device(s) is the responsibility of others A wARMN'•v,!dfy desr;7n Panmeaen and READ A07ES GN 7UTSAND 7MIUDED H27EKREFEREACE PAGE H71- 7473 reo. I/19/20Id8 OMWE Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the WOWerector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication. quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. ' safety Information voi able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. - IiSauihernPine�SRjlumherisspecified,thedesignvaluesarethdseeffettive06 01/2013byALSC Tempe, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence , T6375447 I 270513,. -4 FG03 ' Floor Girder 1 2 Job eefe C0 0 (tonal East Coast Truss, Fort Pierce, FL. 34945 7.520 S Apr ZZ 2014 MITeK Inaustne5, Ina. 1 nu Jun 19 13:13155 ZU14 Page z I D:p?Qm IichP88mXvBBT2NUhcz4kwS-z?UXGGJKcy?kOtC BBF3m GbucdWzyQ 1 Vg_evHavz4jcg NOTES- 11) Special hanger(s) or other connection device(s) shall be provided starting at 0-6-12 from the left end to 20-6-12 sufficient to connect truss(es) to front face of top chord. The designtselection of such special connection device(s) is the responsibility of others. 12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 12-23=-7, 1-11=-182(F=-115) Concentrated Loads (Ib) Vert: 1=-285(F) 6=-429(F) 3=365(F) 4=-429(F) 5=-429(F) 24=-1759(B) 25=-429(F) 26=-429(F) 27=-429(F) 28=-365(F) 29=-285(F) ®WARNIM9•Vndfrdesignparameoera and READ AV7ESGN 7RISAND INCLUDED MITEKREFEREME PAGE M11-1473 — 1129120IQaF7aULM Design valid for use only with MITek connectors. This design 1s based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown ■ Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsiblllity of the MiTek' erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke. East Blvd, Safety Informat1ion vogqable from Truss Plate Institute, 78114, Lee Street, Suite 312, Alexandria, VA 2314. 1t5authemPine�SPftu.berisspecified,thedest.�nvaluesarcthoseeffective05 01/2013hyALSC Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence 'i T6375448 27052 a- \ FG04 Floor Girder 1 2 ' Job Reference (optional) East Coast Truss, Fart Pierce, FL. 34946 1-6-8 i 1-3-0 3x4 = 3x8 = 12 13 11 10 5x5 = 3x4 II LOADING (psf) SPACING- 2-0-0 TCLL 40.0 Plates Increase 1.00 TCDL 10.0 Lumber Increase 1.00 BCLL 0.0 Rep Stress Incr NO BCDL 5.0 Code FBC201O/TP12007 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* 1-11,5-6: 2x6 SP No.2 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:13:56 2014 Page 1 I D:p?Qm IfchP88mXvB BT2NUhcz4kwS-SC1 vTcKyNF7bO1 nOlyb?ppRpnwDl9S1 qD Ieg6Mz4jcf 1-5-0 1-5.0 3x4 = 14 15 3 16 REACTIONS.' (lb/size) 11=1764/Mechanical, 6=2356/Mechanical 9 3x4 = 8 3x4 = , 1-6-8 Scale = 1:19.8 3x4 = 3x8 = 17 4 18 19 5 7 5x5 = 3x4 II CSI. DEFL, in (loc) I/defl L/d PLATES GRIP TC 0.58 Vert(LL) -0.10 8-9 >999 360 MT20 244/190 BC 0.98 Vert(TL) -0.16 • 8-9 >833 240 WB 0.78 Horz(TL) 0.04 6 n/a n/a (Matrix-M) Weight: 114 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-8-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-11=-1681/0, 5-6=-2249/0, 1-12=-2482/0, 12-13=-2482/0, 2-13=-2482/0, 2-14=-4991/0, 14-15=-4991/0, 3-15=-4991/0, 3-16=5560/0, 16-17=5560/0, 4-17=-5560/0, 4-1 8=-3138/0,18-19=-3138/0, 5-19=-3138/0 BOT CHORD 9-10=014162, 8-9=0/5888, 7-8=0/5240, 6-7=0/297 WEBS 5-7=0/3296, 1-10=0/2660, 4-7=-2736/0, 2-10=-2187/0, 4-8=0/416, 2-9=0/1079, 3-8=-408/0, 3-9=-1114/0 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. if front back face in the LOAD CASE(S) section. Ply to `,�>)111 � ffI 2) All loads are considered equally applied to all plies, except noted as (F) or (B) ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. ,�� S p1, -A P q�e� �,� 3) Plates checked for a plus or minus 0 degree rotation about its center. � �\v` ••....... :•. • E N �•.\C' S •••.'9 i 4) Refer to girder(s) for truss to truss connections. ,� 5 "Semi-ri id itchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9� P� 9 Y Y 9 Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to � Z�be "060-6) attached to walls at their outer ends or restrained by other means.7) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 203 Ib down at 1-3-4. 203 Ib downat 2-7-4. 203 Ib down at 3-11-4, 203 Ib down at 5-3-4, 514 Ib down at 6-7-4, 514 Ib down at 7-11-4, 514 Ib down at 9-3-4, and 514 lb'down at 10-7-4, and 1 Ib up at 11-7-4 on top chord. The design/selection of such connection devices) is the responsibility of others." ' �/8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. O• �,a LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 )off O P ,: \_,�. �� •' 0 F{ ��� % • • • • • •' GG \ 1 Uniform LoadVert:6(11 ,,�� BO N A{ -10,1-5=-100 1; Concentrated Loads (lb) Vert: 5=1(B) 12=203(F) 13=-203(F) 14=-203(F) 15=-203(F) 16=-514(F) 17=-514(F) 18=-514(F) 19=-514(F) A^^ June 19,2014 ®WARM1,14-Venfydesign paramea:rs and READ AMESONTNTSAM INaUDED NITEKREEEREKS PAGE 1411.7473 mr. lIZ912025t+F7'OMWE Design valid for use only with Wek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer -not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibillity of the M iTek' erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Salary Inlorma Ion gvapoble from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314 If5outflem ine15PFlumberissimtified, the designvalues are those et#ectivea6;1Q1/2,013hyALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375449 2705%. .I FLOC Floor 13 1 Job Reference (optional casr was i msy, run ognvo 0-3-5 H I 1-3-0 i 5x5 = 3x3 = 3x3 = 3x3 = 1 2 3 4 ID: p?Qm IfchPBBmXVB BT2N Uhcz4kwS-wObHhxLa8ZFSeBMalf6EM0_?MJbOu_AzSy00eoz4jce 1-2-12 1 2-0-0 11 1x4 II 3x3 = 3x3 = 1x4 I I 3x6 FP = 5 6 7 8 9 3x3 = 3x3 = 3x3 = 5x5 = 10 11 12 13 I9 24 23 22 21 20 19 18 17 16 15 14 3x3 11 44 = 3x3 = 3x3 = 3x6 FP = 3x3 = 34 = 3x3 = 44 = 3x3 I I 3x3 = 10-4-10 11-6-2 - p 0-3 1-6-0 2-0-0 2-6-0 2.5-12 0- -s i-0-0 1-0-00- -B 2-5-12 2-0-0 1-6-0 0-3 Plate Offsets (X Y)-- 11:0-2-0 Edoel 113.0-2-0 Edael LOADING (psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.53 Vert(LL) -0.26 18-19 >923 360 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.89 Vert(TL) -0.41 18-19 >590 240 BCLL 0.0 Rep Stress Incr YES WB 0.47 Horz(TL) -0.06 13 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 108 lb FT = 0%F, 0%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except BOT CHORD 2x4 SP No.2(flat) end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=732/0-2-14, 13=732/0-2-14 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 1-2=764/0, 2-3=-761/0, 3-4=-1873/0, 4-5=-2603/0, 5-6=-2994/0, 6-7=-2994/0, 7-8=2994/0, 8-9=-2994/0, 9-10=2603/0, 10-1 1=1 873/0,11-12=-761/0, 12-13=-764/0 BOT CHORD 22-23=0/1402, 21-22=0/2328, 20-21=0/2861, 19-20=0/2861, 18-19=0/2994, 17-18=0/2861, 16-17=0/2328, 15-16=0/1402 WEBS 1-23=0/991, 3-23=-891/0, 3-22=0/656, 4-22=-632/0, 4-21=0/383, 5-21=-358/0, 5-19=-95/434, 13-15=0/991, 11-15=-891/0, 11-16=0/656, 10-16=-632/0, 10-17=0/383, 9-17=-358/0, 9-18=-95/434 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) The solid section of the plate is required to be placed over the splice line at joint(s) 20. 3) Plate(s) at joint(s) 24, 14, 8, 2, 12, 19, 6, 18, 7, 23, 1, 3, 22, 4, 21, 5, 15, 13, 11, 16, 10, 17 and 9 checked for a plus or minus 0 degree � 11.111I f fitp . rotation about its center. 4) Plate(s) at joint(s) 20 checked for a plus or minus 5 degree rotation about its center. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1, 13. �� G E N 5) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. ,���`T.••�,� ic'•.,?%,_�,. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. e * : O 3 938 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. + mj3: ATE [,V . 4 . FL Cert. 6634 �] June 19,2014 AWARNIAIG-Vedfrdesign param.m. and RFAD M17ESGN7NISAND INMIDED MITE1rREFFREAE PAGE MIJ-7473 row I129120IQDITOM SE Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown ■■■ Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibilllty of the M iTek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Salety Inlorma Ion va' able from Jruss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, Vqq 2314 it3outhem ine7SP�lumberisspecified,tinedesignvaluesarethose£ffectivea 01%i013IbyALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6376450 27052 + VAFL02 Floor 4 1 Job Refere ce o io ai Masi Noasl 1 Fuss, run rlerce, rL. 39Y90 s Fyn cc �.a= ID:p?Qm IfchPBBmXVBBT2NUhcz4kwS-Oa9guHMCvtNJFLwmsNdUuE W5c)wpdSfp6g�cg7xBEz4jcd 1-3-0� I 2-0-0 1F-2-1— 2 i Scale=1:30.1 3x3 = 3x6 = 3x3 = 1x4 II - 1x4 I 3x3 = 3x3 = 34 FP = 3x3 = 34 = 5x5 = 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 18 15 14 13 12 3x3 I I 3x4 = 34 = 3x5 FP = 3x3 = 3x3 = 3x3 = 3x4 = 3x3 I I 3x3 = 6-10-12 6-04 LOADING (psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 1-4-0 Plates Increase 1.00 Lumber Increase 1.00 Rep Stress Incr YES Code FBC2010/TPI2007 CSI. TC 0.88 BC 0.92 WB 0.39 (Matrix) DEFL. in (too) I/defl Lid Vert(LL) -0.19 15-16 >999 360 Vert(TL) -0.30 15-16 >666 240 Horz(TL) -0.01 11 n/a n/a PLATES _ MT20 Weight: 91 lb GRIP 244/190 FT = 0%F1 O%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except BOT CHORD 2x4 SP No,2(flat) end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 15-16. REACTIONS. (lb/size) 21=614/Mechanical, 11=614/0-2-14 - FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-21=-613/0, 1-2=-619/0, 2-3=-1485/0, 3-4=-2033/0, 4-5=-2033/0, 5-6=-2033/0, 6-7=-1999/0, 7-8=-1494/0, 8-9=-149410, 9-10=-626/0, 10-11=-629/0 BOT CHORD 19-20=0/1158, 18-19=0/1838, 17-18=011838, 16-17=0/2033, 15-16=0/2118, 14-15=011831, 13-14=0/1148 WEBS 4-17=-425/0, 1-20=0/824, 2-20=749/0, 2-19=0/455, 3-19=-492/0, 3-17=0/614, 11-13=0/815, 9-13=-726/0, 9-14=0/481, 7-14=-469/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 11. 5) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ��f 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0,131" X 3") nails. Strongbacks to S% S A be attached to walls at their outer ends or restrained by other means. ,�� P` 7 Gapbetween inside of to chord bearing and first diagonal or vertical web shall not exceed 0.500in. ♦ �� P s s ♦ pENs•• y �i 8) CAUTION, Do not erect truss backwards. ,♦♦��.••�,� 7 �'•�J!% 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. ' O 9 O .O•• ATE :�4 IV 4,S �O N AX- FL Cert. 6634 June 19,2014 'ANARNIM VedfydesignpammersosariREADMl7TSOMMISANDIM7.UDEDMITFKREfERENCElAraF.Mf1-7473,uaI/79/tOtQUF.YOflFIJSE �e Design valid for use only with Wek connectors. This design is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responslbllllty, of the Nli%k� erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qu�ality cc��ontrol. storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. If5outhernaP"i"i e`SP IbUrnbe 1 sSpeLfied,thedesignvaluesaieth3aseelf#eLtive06110112013byALSC Tampa, FL33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375451 27052A FL03 Floor 1 1 Job Reference o 'e al Casi uoasi truss, 1-on vieree, YL. J4W4b i.ozu a Apr G zu14 "I eK InaUSIDeS, MU. I nU JUn l0 10; 10:00 LV 14 raye 1 ID:p?QmlfchP88mXvB BT2NUhcz4kwS-Oa9guHMCvtNJFLwmsNdUuE W7EjwkdVx66ggc67xB Ez4jcd �♦—I &A ' 2�� 1-2-12 i - Scale = 1:30.1 0 } 3x3 = 3x6 = 3x3 ^ 1x4 II 1x4 II 3x3 = 3x3 = US FP = 3x3 = 3x3 = 5x5 = 1 2 3 4 23 5 6 7 8 9 10 11 3x3 11 3x3 = 3x3 = US FP = 3x3 = 3x3 = 3x3 = 3x3 = 3x3 11 3x3 = B-7-15 7-10-12 1-6-0 4-0-0 5-9-4 5.1 12 6.10.2 B- 10-6-0 11 15-6-0 17.0-0 17-3 1-6-0 2-6-0 1-9-4 0- 0- -13 1-0-0 0- - 2%5 2 2.6-0 2-6-0 1-6-0 0-3 LOADING (psf) SPACING- 1-4-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TIC 0.71 Vert(LL) -0.15 15-16 >841 360 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.92 Vert(TL) -0.22 15-16 >561 240 BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(TL) -0.02 11 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 91 Ib FT = 0%F1 0%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD BOT CHORD 2x4 SP N0.2(flat) `Except* 12-19: 2x4 SP No. 1(flat) BOT CHORD WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 22=303/Mechanical, 11=415/0-2-14, 17=511/0-6-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-22=-298/0, 1-2=-261/0, 2-3=-50610, 3-4=-502/0, 4-23=-502/0, 5-23=-502/0, 5-6=-502/0, 6-7=-967/0, 7-8=-853/0, 8-9=-853/0, 9-10=-397/0, 10-11=-400/0 BOT CHORD 20-21=0/489, 19-20=0/478, 18-19=0/478, 17-18=0/502, 16-17=01502, 15-16=0/844, 14-15=0/994, 13-14=0/71 8 WEBS 4-18=-434/0, 1-21=01347, 2-21=-318/0, 3-18=-222/303, 11-13=01517, 9-13=-445/0, 6-16=-539/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 16-17. 3) Refer to girder(s) for truss to truss connections. ,tilts I I I 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 11. 0 S A 5) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.�P`� A. • A�e �j� 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to `� •, G E N �' •. I be attached to walls at their outer ends or restrained by other means. 7) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 3 93 $ 8) CAUTION, Do not erect truss backwards. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. t� ► '.GATE ..o C? � S.ON Al-E10 ;� 1 rn��il FL Cert. 6634 �] June 19,2014 �WARtdIM-Vmifr d1:.siga pamnrcM. a4d READ k07TS rly TRIS AND jAU,i#DEDMtTEKR£FF.XEtKki FS4GE,Nlr-Mli nr. r, ii i20Id8FF0AEtJSF. �! Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an individual building component. s �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity, of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety I lorma Ion Slvailoble from Truss Plate Institute, 781 N. Lee Sireef, Suite 312, Alexandria, Vq 2314. ifSaut�lem irte`SPyium4mrisspecified,thadesig"valuresarethoseei#tctave40112013hyALSC Tampa, FL 33610.4115 L Job Truss Truss Type Qly Ply Gingres Residence ' T6375452 27052t' 'r' FL04 Floor 3 1 Job Reference (optional) eaaw"em uu run Howe, ram. .,vavo - npi ca - — ID:p7Qm lfchP88mXvBBT2NUhcz4kwS-snj25dMggAVAtWzQ48jRR3le7G7MyAGvGtUjgz4jcc �r 1-3-0 "6- ' 2r 0-0 ' 1i� 3- Scale = 1:30.1 3x3 = 3x6 = 30 = tx4 II 1x4 13x3 = 3x3 = 3x6 FP = 3x3 = 3x3 = 5x5 = 1 2 3 4 23 5 6 7 8 9 10 11 3x3 11 3x3 = 3x3 = 3x6 FP = 3x3 = 3x3 = 3x3 =' 3x3 = 3x3 11 3x3 = 1$-0 4-0-0 5-94 6-6-0 8-0-4 , 10-6-0 13-0-0 15-6-0 17-0-0 17-3$ 1-9d 0.8-12 1-0-12 2-5-12 2-6-0 2-6-0 1-6-0 OL3� LOADING'(psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 1-4-0 Plates Increase 1.00 Lumber Increase 1.00 Rep Stress Incr YES Code FBC2010/TP12007 CSI. TC 0.73 BC 0.92 WB 0.25 (Matrix) DEFL. in (too) I/dell L/d Vert(LL) -0.15 15-16 >824 360 Vert(TL) -0.22 15-16 >548 240 Horz(TL) -0.02 11 n/a n/a PLATES MT20 Weight: 91 lb GRIP 244/190 FT = 0%F, O%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 SP No.2(flat) *Except* end verticals. 12-19: 2x4 SP No.1(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP Nc.3(flat) 2-2-0 oc bracing: 16-17. REACTIONS. (lb/size) 22=303/Mechanical, 11=417/0-2-14, 17=508/0-6-0 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 1-22=-299/0, 1-2=-262/0, 2-3=-506/0, 3-4=-514/0, 4-23=-514/0, 5-23=-514/0, 5-6=-514/0, 6-7=-979/0, 7-8=-860/0, 8-9=-860/0, 9-10=-400/0, 10-11=-403/0 BOT CHORD 20-21=0/490, 19-20=0/483, 18-19=0/483, 17-18=0/514, 16-17=01514, 15-16=0/858, 14-15=0/1003, 13-14=0/722 WEBS 4-18=-446/0, 1-21=0/349, 2-21=-318/0, 3-18=-219/319, 11-13=01521, 9-13=-449/0, 6-16=-537/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. ,1111111,��, 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 11. ��� S A. � 5) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ,�� �p`� • , 'q�e 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to �� Q •,• (, E S •• q,* be attached to walls at their outer ends or restrained by other means. ,�A`�.• � m•_'..•.7� e 7) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. p� 39380_ 8 CAUTION, Do not erect truss backwards. * 9) Warning: Additional permanent and stability bracing for truss system (not part. of this component design) is -always required. _ Mx :O, LATE r S < 0 Fi kV c*�N ON AI- E,•�'% FL Cert. 6634� June 19,2014 WAR NJUK' Verify design panmeren and RFA0 AV7ESGN 7141`6 AM lM.UbE'D11.TF.KRFFIRF.ME PA6IT; Art I- M73 i:.. IJd.912ni1MGM 15E Design valid for use only with Wek connectors. This design is based only upon parameters shown, and Is for an individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the iVliTek� erector. Additional permanent bracing of the overall structure Is the responsibility of the Wilding designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/71`I1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. S lety I Iormaflon vai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Tampa, FL 33610-4115 1 SuutuernF�iT1e�5# lurnburisspecrfled,thedesignvaluesatetheseeffecttive05 01j2013by'AtSC Job Truss Truss Type Qty Ply Gingras Residence T6375453 27052, ='i FL05 Floor 1 1 ob Reference (optional East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITek industries. Inc. Thu Jun 18 13:14:ou zu14 Page 1 I D:p7Qm IfchP88mXvB BT2NUhcz4kwS-KzHQJzNSRUdl Ve49_ofyzfcYcXgM5SDP8wc2F7z4jcb 03-6 5x5 = 3x3 =. 3x8 = i11 i 1-2-8 9 i 1-3-0 a. 3x3 II 8 3x3 5 3x3 II Scale = 1:9.6 0-3-8 1-8-14 3-2-14 ' 0-3-8 1-5.8 1-6-0 Plate Offsets (X Y)-- t1.0-2-0 Edoel LOADING (psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.40 Vert(LL) 0.00 5 >999 360 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.02 Vert(TL) 0.00 5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code FBC2010/TPI2007' (Matrix) Weight: 22 lb FT = 0%F, 0%E LUMBER. BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 3-2-14 cc puriins, except BOT CHORD 2x4 SP No.2(flat) end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (lb/size) 4=99/Mechanical, 1=99/0-2-14 FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 4) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between Inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. FL Cert. 6634 June 19,2014 ®WARNIMi Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. �• Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown �■p s is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibilllty, of the iV�il'ek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety I forma Ion. val able from Truss Plgte Institute, 781 N. Lee Street, Suite 312, Alexandria, Vq 2314 Tampa, FL 33610-4115 It5outlem ne�SP lumberisspecifiedrthedes% values are thasceffettive0bfO1f1O13byAM Job Truss Truss Type Qty Ply Gingras Residence T6375454 27052 -J -Hit Jack -Open 1 1 Job Reference o do al east uoasl 1 russ, Yon Pierce, FL, Mld46 I -a -a s pi cc av w .!I ion „— , ,,,. ,.,. . . .,e„ . ID:p7QmlfchP88mXvBBT2NUhcz4kwS-KzHQJzNSRUd1Ve49 ofyzfcegXg55SHP8wc2F7z4jcb v ch d In Scale = 1:6.2 1.8-2 0-b14 Plate Offsets (X Y)-- 11:0-8-9 0-0-81 11.0-2-0 Edael LOADING (psi) SPACING- 2-0-0 CSI. DEFL, in (too) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TIC 0.05 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.03 Vert(TL) -0.00 4 >999 180 SCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 5 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-8-6 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer -Installation e REACTIONS. (lb/size) 1=200/0-6-12, 3=-13/Mechanical, 2=-28/Mechanical Max Horz 1=20(LC 4) Max Uplift 1 =-1 71 (LC 4), 3=-13(LC 1), 2=-28(LC 1) Max Grav 1=200(LC 1), 3=7(LC 4), 2=24(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60' plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord I've load —concurrent with any other live loads. 4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 1�1' f I'l fit between the bottom chord and any other members. ,,� ,IS A. q� �J., 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 171 lb uplift at joint 1, 13 lb uplift at joint 3 `�% 0 ,•'� C E•N S+'• ^99�i�i and 28 lb uplift at joint 2. /` : • �' r-,_._ -•�'. •y ti. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. _`,� p 3 938 0_ Mr^ •�4/1� ATE 110'If5 t,EON� ®wARNrNu•Yenry design pmametea aad READ h07ES ON 7N7S AND MUDED MI TFKRffERENM PAGE MIJ-74;9 m.-If29/201daff REME Design valid for use only with MTek connectors. This design is based any upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building' designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Salety Information gqvarpble ffr�om Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexanoria, VA 2314. ii5outhernPirre`fiPplumherisspecitied,thedesia uatuesarethoseeffetra1re06 d71J2t713byAi5C FL Cert. 6634 June 19,2014 M!Tek' 6904 Parke East Blvd. Tampa, FL 33610-4116 Job Truss Truss Type Qty Ply Gingras Residence T6375455 27052t -HJ3 Jack -Open 1 1 Jo b a erence o tionai East Coast Truss, Fort Pierce, FL. 34946 m d 7.520 S Apr 22 2014 MITeK Industries, Inc, Thu Jun 19 13:14:U1 ZU14 Nage 1 ID: p7Qm IfchP88mXvB BT2N Uhcz4kwS-o9roWJ04Bomu6ofLXVABWsBnTx7MgvAZMaMbnZz4jca 3-7-12 1-4-10 1-10-4 3-7-12 1-4-10 0-5.10 1-9-8 Scale =1:7.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in ([cc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.14 Vert(LL) -0.01 6 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.16 Vert(TL) -0.02 6 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.02 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 12 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-7-12 cc purlins, BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation REACTIONS. (lb/size) 1=309/0-11-5, 3=-44/Mechanical, 5=72/Mechanical Max Horz 1=38(LC 4) Max Uplift 1=-110(LC 4), 3=-44(LC 1), 5=-54(LC 4) Max Grav 1=309(LC 1), 3=35(LC 4), 5=72(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 31 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,,��41 fit between the bottom chord and any other members. ,,�� PS A q / �I♦♦ 5) Refer to girder(s) for truss to truss connections. �•,. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 Ito uplift at joint 1, 44 Ito uplift at joint 3 ,���� ,• i✓ E N S 4n 9 ♦i♦ and 54 lb uplift at joint 5. �� /L F•�',-"-1! 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. W61-9 380 '•s i 411 '. ATE ���S 0 N A� �?%% ®WARNMU•Verity design parurreocrs snd RE1D h07ESON-MISAIR1 JKLUDED MITFXREFEREACE PAGE MU-2473 m,R I/29/20I4aIi0H ME Design valid for use only with MTekconnectors. This design is based only upon parameters shown, and is loran individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibillity, of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Safety Informa11lgn valIable from Truss Plate In titute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. If SoutherrtPis SPplumbelislspedifiel�. the design values ate those effectiue06 0112013hyALSC FL Cert. 6634 :] June 19,2014 IMF MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingres Residence T6375456 27052 + , ..'It Jack -Open 1 1 Job eference o t'o al East Coast Truss, Fort Pierce, FL. 34946 2-8.9 v A d 7.520 s Apr 22 2014 MTek Industries, Inc. Thu Jun 19 13:14:01 2014 Page 1 ID:p7QmlfchP88mXvBBT2NUhcz4kwS-o9roWJ04Bomu6ofLXVAB Ws8oTx8WgvMZMaMbnZz4jca Scale = 1:7.8' LOADING (psf) SPACING- 2-0-0 CSI. 'DEFL, in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.07 Vert(LL) -0.00 6 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.01 6 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.01 Horz(TL) . -0.00 3 n/a n/a BCDL 10.0 Code FBC2010rTP12007 (Matrix-M) Weight: 9 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-8-9 cc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation REACTIONS. (lb/size) 1=228/0-8-4, 3=-17/Mechanical, 5=401Mechanical Max Horz 1=33(LC 4) Max Uplift 1 =-55(LC 4). 3=-17(LC 1), 5=27(LC 4) Max Grav 1=228(LC 1), 3=12(LC 4), 5=41(LC 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,,�>11� fit between the bottom chord and any other members. _A 5) Refer to girder(s) for truss to truss connections. ��� \V`P• . • ..... .14 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift at joint 1, 17 lb uplift at joint 3 Z. �� ,• •� C E + •• q �i� and 27 lb uplift at joint 5. ,I � ; • �---' F�'••? 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.00 `38 • 1 ATE A`EC� �. FL Cert. 6634 June 19,2014 ®WARNING . yeri£f desiSn pann+.4ers and AfAa M17ESGN7NTSAND lNQUbE0 r4iT£KREFER:ME'FiiGE N77-M73 m-a l%t9/70[daEFWiEtAE Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters. and ptoper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the MITeK• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer, For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. s laty Information vat able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314 1�5o uthe M Pme�Sp� lumber is spec ilied, the design values are these effevtive 46/02/1013 by ALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375457 2705q- �. -HJS Roof Special Girder 1 1 Job Reference (ootionall tast coast i russ, ton Pierce, ru. MO I*0fu s Apr a ZU14 mi i eK mousmes, mc. i nu uun to t s:w:uz zu14 rage I ID: p7Qm IfchP88MXvBBT2NUhcz4kwS-GMPAkfPjy5ulkyEY5DhQ34hvEKThZMOibE59K7z4jcZ 5-10-14 5-10-14 Scale = 1:12.1 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plates Increase 1.25 TC 0.33 TCDL 17.0 Lumber Increase 1.25 BC 0.15 BCLL 0.0 ' Rep Stress Incr NO WB 0.02 BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER. TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=249/0-9-11, 2=245/Mechanical, 4=-21/Mechanical Max Horz 1=68(LC 4) Max Uplift 1 =-1 34(LC 4), 2=-169(LC 4), 4=-25(LC 28) Max Grav 1=358(LC 28), 2=245(LC 1), 4=87(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -Ali forces 250 (lb) or less except when shown. 2x4 II 3 DEFL. In (loc) I/deft L/d PLATES GRIP Vert(LL) -0.01 4-8 >999 240 MT20 2441190 Vert(TL) -0.02 4-8 >999 180 Horz(TL) -0.00 2 n/a n/a Weight: 19 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-10-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installatione NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=241t; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will �11111111!/,, fit between the bottom chord and any other members. 5) Refer to for truss to truss connections. ���� S A. •.. �P`•. • • • A�e ��i girder(s) 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 134 lb uplift at Joint 1, 169 Ito uplift at Joint 2 25 lb 4. %�`' `.�� �� ,•'� G E N g • • '9 ��� F���...� !, and uplift at joint 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. �� ••• : 9 $ 3� • • •••� 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 1,�^ ` 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 90 lb down and 141 Ito up at 1-8-5, - 90 lb down and 141 lb up at 1-8-5, and 103 lb down and 89 lb up at 5-3-2, and 103 lb down and 89 lb up at 5-3-2 on top chord, and 21= lb down and 13 lb up at 5-3-2, and 21 lb down and 13 Ib up at 5-3-2 on bottom chord. The design/selection of such connection � IZ Z device(s) is the responsibility of others. i'�-•. ATE 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). 1.0. O •• �C/ LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 �i �` �'•. 0 R \G �� ��I StS �" • `" �` Uniform Loads (plf) Vert: 1-9=-74 3-5=-20 �!!lllllllll Concentrated Loads (lb) Vert: 10=140(F=70, 8=70) 11=-49(F=-25, 8=-25) 12=-7(F=-3, B=-3) FL Cert. 6634 ::] June 19,2014 ® WARMIfr - Venfr design p---b— and READ MUS GM MIS AND INCUMED MITEXR£FEREME PAGE NII.2473 ma I124/2016WMEWE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown ■ Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the MiTek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. IfSautliernaP nelSP)lulmherisspeci iedithedel5gLee raluesa eithaseelifeitdive46A 112013byALSC Tampa, FL33610-4115 Job Truss Truss Type Oty Ply Gingras Residence T6375458 27052,E � -HJ58 Diagonal Hip Girder 1 1 Job Reference (optional) Last coast i russ, ran Pierce, f-L. 34e4b 6.11-6 r.ozu s Apr "ZU14 M1 i OK maustnes, inc. i nu aun ie ian4:ua zu 14 rage I ID: p?QmifchP88mXVBBT2NUhcz4kwS-kYyZx?PLjPOcM6pkfwDfbHE3AknDlpOsqurisSz4jcY 3x4 3x4 11 Scale = 1:13.3 1-4-4 1-2 6-11-6 1-4-4 0-5-10• 5-1-8 Plate Offsets (X Y)— 11.0-11-3 0-2-71 11:0-3-0 Edoel LOADING (psf) SPACING. 2-0-0 CS]. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.44 Vert(LL) -0.01 5-9 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.02 5-9 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC2010ITP12007 (Matrix-M) Weight: 22 Ito FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-d oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide, REACTIONS. (lb/size) 1=441/0-11-5, 5=226/Mechanical Max Horz 1=90(LC 5) Max Upliftl=-182(LC 4), 5=-83(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=0ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to for truss to truss connections. ,,��/ ,�% PS A. �e �j girder(s) 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 182 lb uplift at joint 1 and 83 lb uplift at joint�� % %� ,•'� G•E•N �i • �' S�•�q�y 5. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. � �® . Z •• of "" 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 100 lb down and 72 lb up at 4-1-14,� * w and 76 Ito down and 64 lb up at 4-1-14 on top chord, and 16 lb down and 34 lb up at 1-3-15, and 32 lb down and 24 Ito up at 4-1-14, an; 8 Ib down and 27 lb up at 4-1-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. front back 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as (F) or (B). ::� :. SATE Z LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pif) Q ••. W �j�'C� Q;•' ��,�� I�� •. 0 R �� Vert: 1-2=-74, 2-3=-74, 4-6=-20 , `� SS'J /O Concentrated Loads (lb) Vert: 8=-16(F)10=13(F=24,B=-11)11=-1l(F=15,B=-26), i111 N A� `',�� FL Cert. 6634 June 19,2014 ®WARNIM • Vedly drsgn paameesn aad READ AV IES ON rNTSAND IMQ BDEn MMKREFEREACEPAGE MII• MY3 mr. I/29/20IQBUOAEUSE Design valid for use only with MITek connectors. This design is based any upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responslbillity of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality storage, delivery, erection and bracing, consult ANSI/17I1 Quoin Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. gcontrol, Safe js ss Plate Ingtitute, 781 Lee Street, Suite 312, AI xandda, VA 2314. i t5outiie la ne va lumber sprecifieU,thedesl nualuesaretfioseei�festave0fi 01120131zyALSC Tampa, FL 33610.4115 Job Truss Truss Type City Ply Gingras Residence T6375459 2705k D -HJ7 Diagonal Hip Girder. 3 1 b Reference (optionall East Coast Truss, Fort Pierce, FL. 34946 - 7.520 s Apr 22 2014 MITeK Industries, Inc. Thu Jun 19 13:14:03 2014 Page 1 ID:p?QmlfchP88mXvB BT2NUhcz4kwS-kYyZx?PLjPOcM6pkfwDfbHE2skjHlnl squrisSz4jcY 5-5-15 9-9-5 5-5-15 4-3-6 Scale = 1:18.3 3x4 II 1-410 1-10-4 5.5-15 9-9-5 LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr NO Code FBC201 O/TP12007 CSI. TC 0.46 BC 0.51 WB 0.19 (Matrix-M) DEFL. in Vert(LL) 0.04 Vert(TL) -0.08 Horz(TL) 0.01 (loc) I/deft Ud 6-7 >999 240 6-7 >999 180 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 38 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 1=536/0-11-5, 6=428/Mechanical Max Herz 1=127(LC 5) Max Upliftl=-225(LC 4), 6=-154(LC 4) FORCES. (lb) -'Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 1-12=-687/280, 2-12=-648/260 BOT CHORD 1-11=-277/96, 1-8=-2081647, 1-14=-264/647, 7-14=-264/647, 7-15=-2641647, 6-15=-264/647 WEBS 2-6=-560/243 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS left exposed end vertical left and right exposed; Lumber DOL=1.60 (directional); cantilever and right ; DOL=1.60 t111111111111111,� A. plate grip 2 Plates checked fora or minus 0 degree rotation about its center. ♦�♦� Pcj ♦ �e plus 3) This truss has been designed for a 10.0 psf bottom chard live load nonconcurrent with any other live loads. ,�� "O , •.. G E N S ... 1 �# 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.. ; A` V j 0 39380., 5) Refer to for truss toti truss connections. -� girder(s) 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 225 lb uplift at joint 1 and 154 lb uplift at joint 6. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used 1n the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 76 lb down and 64 lb up at 4-1-14, o ; •' ,_ qT E / 76 lb down and 64 lb up at 4-1-14, and 119 lb down and 93 lb up at 6-11-13, and 119 lb down and 93 lb up at 6-11-13 on top chord, and 16 lb down and 34 lb up at 1-3-15, 8 Ib down and 27 lb up at 4-1-14, 8 lb down and 27 lb up at 4-1-14, and 26 lb down and 11 lb o 0'• .0 T �•. �� P .' up at 6-11-13, and 26 lb down.and 11 lb up at 6-11-13 on bottom chord. The design/selection of such connection device(s) is the �40responsibilR Q N_`�� ,of c `�j ♦♦� ty others.,��V�s 9) In the LOAID CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). �O N A' `;,`% LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 FL Cent, 6634 June 19,2014 Continued on Paqe 2 ®N'ARNIM •Vwtty de.sr.7n paaunww x and RF46 Aa7F.SdN7N75AND IM7.VVFD MITFICRFFF.RENCFPASE MII-1473 am 1f29J2e148FfaafUM Design valid for use any with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. . Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown ii��YY■ Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsiblllity, of the MiTek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety qqvo able from Truss Plate In titute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. It fiaInformation uthern Pine `SP� lumber isspecifiel > theclesign values are them effective 06 0112013 by ALSC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Gingras Residence T6375459 27052p- -HJ7 Diagonal Hip Girder 3 1 'Job Reference (optional East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITek Industries, Inc. I nu Jun 19 1J:14:UJ ZU14 Yage Z ID:p?Qm IfchP88mXvB BT2NUhcz4kwS-kYyZx?PLjPOcM6pkfwDfbH E2skjHlnl squrisSz4jcY LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-74, 3-4=-74, 5-8=-20 Concentrated Loads (lb) Vert: 10=16(F) 12=47(F=24, 13=24) 13=-86(F=43, 13=43) 14=30(F=15, B=15) 15=-21(F=-11, B=-11) �WARNMG Verify desdlnpara—&-snd IRFAD M USGMMISAMD INaUDED MMKIIEFEREACE PAGE Mil-7413 mn I/291201dW'aN WE Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability dudng construction Is the respo'nsibillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 69D4 Parke East Blvd. Safety Information va able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314.. 7frsouthern4tine�SP lumherisspecified,thedeslgnvaluesarethoseeffective46 01/2013byALSC Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply Gingras Residence 1 T6375460 27052y- "Job -HJ7A Diagonal Hip Girder 2 1 Reference (optional) East Coast Truss, Fort Pierce, FL. 34946 7.520 a Apr 22 2014 MITeK Industries, Inc. Tnu Jun 19 13:14:U4 ZU14 Page 1 ID:p7QmlfchP8BmXvBBT2NUhcz4kwS-DkWx9LQzUj8T GOwDekuBVmD982R1B1?3YaFOuz4jcX' 5-6 5 9-10-1 5-6-5 4-3-12 Scale = 1:18.4 3x4 11 LOADING (psf) TCLL 20.0 TCDL 17.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr NO Code FBC2010/TPI2007 CSI. TC 0.49 BC 0.58 WB 0.27 (Matrix-M) DEFL. in Vert(LL) 0.04 Vert(TL) -0.10 Horz(TL) 0.01 (loc) I/defl Ud 7 >999 240 6-7 >999 180 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 3B lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-7-0 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=583/0-8-8, 6=499/Mechanical Max Horz 1=128(LC 5) Max Uplift 1 =-209(LC 4), 6=-161(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-12=-923/281, 2-12=-890/296 BOT CHORD 1-8=-245/877, 1-14=291/877, 7-14=291/877, 7-15=-291/877, 6-15=-291/877 WEBS 2-6=-786/282 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 ,olll 11////, 2) Plates checked for a plus or minus 0 degree rotation about Its center. ,r.% PS A, q 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will `�� �0 ,•'� G•E N 5+ fit between the bottom chord and any other members. �� /` ; • �,-.� �•, �! 5) Refer to girder(s) for truss to truss connections. 'r39380.. --- -� 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 209 Ib uplift at joint 1 and 161 Ib uplift at ` * / � joint 6. e 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 100 lb down and 72 lb up at 4-1-14 : � f(r ;, 76 lb down and 64 lb up at 4-1-14, and 135 lb down and 98 lb up at 6-11-13, and 119 lb down and 93 lb up at 6-11-13 on top chord, � (U and 32 lb down and 24 lb up at 4-1-14, 8 lb down and 27 lb up at 4-1-14, and 47 ib down and 3 lb up at 6-11-13, and 26 lb down and ATE 11 lb up at 6-11-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. �� • C�t��•. �4 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). �I�\`s . 0 R !•� `�j ,�� LOAD CASE(S) Standard. -/s,O N A; 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-74, 3-4=-74, 5-8=-20 FL Cent. 6634 June 19,2014 A WARNIM Vedrydasigu panmew—d READ A07ESGNMISANDINCLUDED Mr7EKNE'FERE'N..F PAGE MrI-74731.. 11291201JI CREIM R Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component.® Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown i Is for lateral support of individual web members only. Additional temporary bracing to insure stablllty during construction is the responslbillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safe Information gva able from Truss Plate In fltute, 781 N. Lee Street, Suite 312, Alexandria, VA 2 14. Tampa, FL 33610-4115 IfSotyuthernrinelSIX lumberirsspecifie ,the designvaluesarethoseeffective06�0 12013byAtSC P' Job Truss Truss Type Qty Ply Gingras Residence T6375460 270524, ► -HRA Diagonal Hip Girder 2 1 Job Reference opt 'o al east coast 1 russ, r•ort Tierce, M. a4e4b 7.szu s Apr zz zu14 mi iek mausines, mc. r nu dun 1'd 13:14:u4 zu14 Fage z ID:p7QmifchP88mXvBBT2NUhcz4kwS-DkVNc9LQzUjBT_GOwDeku8VmD982R1 B173YaFOuz4jcX LOAD CASE(S) Standard 'Concentrated Loads (lb) Vert: 12=13(F=-11, 13=24) 13=-109(F=-66, B=-43) 14=11(F=-26, B=15) 15=-51(17=40, B=-11) ITARNLhC3 Veritr 3esign Nnr+�+ne0lrs sa07iFi1d hU7ESGN MirSA2A 7HLti1fYi0 MITi7rftF.fLRF.At>~-A4GE AfrhM73 Tea !/d9/IQ[Q BEFONEA/.SE Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibilliy of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer.. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component iafay Inlormatl I 7vailable from Truss Plate Institute. 781 N. Lee StreetlSuite 312, Alexandria, VA 22314. 1i5outhem ine 5p lumberissoecified,thedeSienuatuesaT�ethoseeffecGue0610 12013IdyAtSC Nil' WOW 6904 Parke East Blvd. Tampa, FL 33610.4115 Job Truss Truss Type Ply Gingras Residence T6375461 27052, MG01 ]Qty MonopReh Girder 1 1 Job Re ere ce o Tonal East Coast Truss, Fort Pierce, FL. 34946 7.520 s Apr 22 2014 MITek Industries, Inc. Thu Jun 19 13:14:05 2014 Page 1 I D:p?Qm IfchP88mXvBBT2N Uhcz4kwS-hw4JMhRbFOGKbQz6mLF7giJKEYOjmiWBHCKpwKz4jcW L 7-0-0 7.0-0 3x4 % Scale = 1:15.4 4x8 M18SHS II HUS26 i 1-0.0 1-40 7.0-0 _ 1-0.0 0.4.0 5-8-0 Plate Offsets (X Y)- 11.0-10-12 Edgel 11.0-1-4 Edgel f2.0-0-12 0-1-81 f3•Edge 0-3.81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.73 Vert(LL) 0.07 3-7 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.58 Vert(TL) -0.17 3-7 >475 180 M18SHS 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) 0.01 3 n/a n/a BCDL 10.0 Code FBC2010fTP12007 (Matrix-M) Weight: 29 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x6 SP SS end verticals. WEBS 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 9-9-11 oc bracing. M,Tek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=1368/0-8-0, 3=968/Mechanical Max Horz 1=141(LC 18) Max Uplift 1 =-395(LC 4), 3=-288(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-339/257, 1-2=-320/110 BOT CHORD 1-8=-122/284, 8-9=-122/284, 3-9=-122/284 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpl=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. `,,�1111111/�I�I' 3) Plates checked for a plus or minus 0 degree rotation about its center. ,�%PS A. A f,, 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. % OO , 5) •This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,� ,•'� C E N S n• '9 �� fit between the bottom chord and any other members, ,� ; • V C, ��, 6) Refer to girder(s) for truss to truss connections. 7 Provide mechanical connection b others of truss to bearinglate capable of withstanding395 lb uplift at joint 1 and 288 lb uplift at 3 938 0.�--YS joint 3. 8) 'Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 9) Use Simpson Strong -Tie HUS26 (14-10d Girder, 4-1 Od Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 1-8-4 - Mir Z from the left end to 5-8-4 to connect truss(es) to back face of bottom chord. C-'TAT E .• 10) Fill all nail holes where hanger Is in contact with lumber. 11/ 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).OR �� T,(•�. �� OG�`.' �_,�� LOAD Andard Roof Live )a(balanced):Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) �"#nf 11IIt%%% Vert: 1-2=74, 1-3=-20 Concentrated Loads (lb) Vert: 7=-570(B) 8=-563(B) 9=-558(B) FL Cert. 6634 June 19,2014 ®WARNIM-V"Iffde.s,3.Firm emaand RFADAVUSON USAM)JtX7.tRJDNI7FKRFFlRF.MEFAGSNIJ-M):imarjd4f2r1JdaffDREUSE Design valid for use only with Wek connectors. This design Is based only upon parameters shown, and is for an Individual building component. �• Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown ■ Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the iVliTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DS,B-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information vai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Tampa, FL 33610.4115 1f Southern R"Ine�SP� lumber isspetiiied, the design values aTe those of#ective Ofi/01f2R13 byALSC Job Truss Truss Type Qty Ply Gingras Residence T6375462 27052� to MV3 Valley 1 1 Job Refers ce o do a East Coast Truss, Fort Pierce, FL. 34946 7,520 s Apr 22 2014 MTek Industries, Inc. Thu Jun 19 13:14:052014 Page 1 I D:p?QmlfchP88mXvBBT2NUhcz4kwS-hw4JMhRbFOGKbQz6mLF7giJ NBYPgmiW8HCKpwKz4jcW 3-0-9 3-0-9 3.00 12 3x4 Scale = 1:6.5 LOADING (psf) SPACING- 2-0-0 CSI, DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) -0.00 1-3 >999 240 MT20 244/190 TCDL 17.0 Lumber Increase 1.25 BC 0.55 Vert(TL) -0.01 1-3 >999 180 BCLL ' 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2010/rP12007 (Matrix) Weight: 7 Ito FT = 0% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=8013-0-9, 3=92/0-3-8 .Max Horz 1=59(LC 8) Max Uplift 1 =-79(LC 8). 3=-112(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation 6uide. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=Oft; 13=45ft; L=24ft; eave=4ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=4.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by•2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 1 and 112 Ito uplift at joint ,,`j11I 3. �%% PS A. 4 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 1�� O�•,.. • �e �i, Fd'o 393 80 C— v ATE FL Cert. 6634 :] June 19,2014 AWAR1QMi-Ya lydes7npanmesenandAFAI)AVUSCHMISANDIMVDEDMLTFKREFEREACFPAGE TELL-M73re,.Ift912OLSBEFMME Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsiblllity of the M iTek' erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety InlormarrIon vai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. ftSouthernF�tne�SPlumber isspetitied, the design valu�esate these effectfive06 10I/2013byALSC Tampa, FL 33610-4115 Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION 3j4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. J�Apply plates to both sides of truss and fully embed teeth. 0 -' -. �16 For 4 x 2 orientation, locate plates 0-'na' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: iANSI/TPII : National Design Specification for Metal �* Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) I 2 i TOP CHORDS cr-2 c2-s o WEBS c� 4 0 O a_ O C7-8 C67 C5-6 O F BOTTOM CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ]CC -ES Reports: ESR-1311., ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Southern Pine lumber designations are as follows: SYP represents values as published by AWC in the 2005/2012 NDS SP represents ALSC approved/new values with effective date of June 1, 2013 0.2012 M7i ek@ All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev. 01 /29/2013 Failure to Follow Could Cause Property Damage or Personal Injury . 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSL 2. Truss bracing must be designed by an'engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and n6ver stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may'pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.