Loading...
HomeMy WebLinkAboutTSP106239 ISABELLA DICHARD 01 31 2022 STAMPED 01 31 2022PV STRING INVERTER #1 PV DISCONNECT EXISTING ELECTRIC METER FLAT SYSTEM CAPACITY: 5.14 KW DC / 5.0 KW AC PV PANELS: (13) Q. PEAK DUO BLK ML-G10+395 BY Q CELL OPTIMIZERS: (13) P505 BY SOLAREDGE INVERTER: (1) SE5000H-US BY SOLAREDGE RACKING SYSTEM: CROSS RAIL SYSTEM 44-X BY K2 SYSTEMS COVER SHEET C-1 1 PROJECT LATITUDE PROJECT LONGITUDE WIND EXPOSURE MIN AMBIENT TEMP MAX AMBIENT TEMP AHJ 27.551839 -80.393079 º C DESIGN WIND SPEED PROJECT DESCRIPTION C-1 COVER SHEET E-1 E-2 S-1 S-2 D-1 PV MODULES DATA SHEET GENERAL NOTES B 157 ST LUCIE D-2 D-3 SMART MONITORING DATA SHEET INVERTER DATA SHEET RACKING PLAN SAFETY LABELS STRUCTURAL PLAN ONE LINE RISER DIAGRAM 35 0 º C MPH C-2 SAFETY PLANS ROOF PLAN VIEW / BOS LOCATION1N.T.S. LOCATION MAP / WIND ZONES2N.T.S. IRRADIANCE MAP3N.T.S. 3D RENDERING4N.T.S. DRAWINGS INDEX PROJECT INFORMATION NORTH OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC PER FL. STATUTE 377.705 (REVISED 7/1/2017), I RAFAEL A. GONZALEZ SOTO, P.E. 83104 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. APPLICABLE CODES: 2020 FLORIDA BUILDING CODE 7TH EDITION, ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES, FFPC 7TH EDITION, NFPA 2018, NFPA 70 AND NEC 2017. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2020 FLORIDA BUILDING CODE 7TH EDITION OR LOCAL GOVERNING CODE. ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (NEC) 2017, LOCAL STATE CODES, AND OTHER APPLICABLE LOCAL CODES. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING. CONNECTORS TO BE TORQUED PER DEVICE LISTING, OR MANUFACTURERS RECOMMENDATIONS. NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING. REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE, OR OTHER MECHANICAL MEANS, LABELS SHALL COMPLY WITH ARTICLE 690 VI OF THE NEC 2017 OR OTHER APPLICABLE STATE AND LOCAL CODES. SEE LABELS AND MARKING PAGE FOR MORE INFORMATION. RACKING ROOF MOUNT SYSTEM SHALL BE INSTALLED FOLLOWING MANUFACTURERS INSTRUCTION SPEC'S, INCLUDING ALL GROUNDING WEEB CLIPS, GROUND LUGS, AND RAIL SPLICE KITS FOR ELECTRICAL CONTINUITY. MECAWIND TOOL IS BASED ON THE C&C WIND LOADS FOR ENCLOSED BUILDINGS. DESIGN WIND PRESSURES ARE CALCULATED USING ASCE 7-16 EQUATION 30.6-1. ALL NOTES IN FIGURES ASCE 7-16 30.4-1 AND 30.4-2(A,B AND /67C) HAVE BEEN INCORPORATED. MEAN ROOF HEIGHT MUST BE LESS THAN 60 FEET. "PROPERTY SIDE FACING STREET" 1 1 1 UPDATED LAYOUT AS REQUESTED1 1-28-22 JH NT NORTH PV STRING INVERTER #1 PV DISCONNECT EXISTING ELECTRIC METER FLAT SAFETY PLAN C-2 OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC NOTES: 1.INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME 2.INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST URGENT CAR FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK NAME: LOCATION OF NEAREST URGENT CARE FACILITY ADDRESS: PHONE NUMBER: SAFETY PLAN1N.T.S. 2 "PROPERTY SIDE FACING STREET" 1 UPDATED LAYOUT AS REQUESTED1 1-28-22 JH NT 6 JB NEMA3R 3 4 5 6PV RAILS TO BE BONDED WITH #8 BARE WIRE 1 A1.1 1 A2.1 A1.2 A1.3 A1.4 A1.5 A1.6 A1.7 A2.1 A2.2 A2.3 A2.4 A2.5 A2.6 STRING #1 STRING #2 2 EXISTING OVERHEAD SERVICE 240V/120V 200A BUS BAR 3 #2/0 THWN-2 INVERTER TOTAL OUTPUT: 21A SAFETY RATING (125%): 26.25A TOTAL PV SYSTEM OCPD: 30A MAIN BREAKER RATING: 200A BUS BAR RATING: 200A 120% BACKFEED RATING: 40A METER200A 1 #4 THWN-2 GROUND 9 10 7 8 FUSED 30A LEGEND: 1 4 7 10 2 5 8 11 3 6 9 12 NOT USED PV SYSTEM DISCONNECT FUSED RATED FOR 30A UTILITY ELECTRICAL SERVICE 4 #10 THWN-2 1 #8 THWN-2 GROUND 3/4" EMT CONDUIT 4 #10 PV WIRE 1 #8 BARE WIRE GROUND 3/4" EMT CONDUIT 2 #6 L1,L2 THWN-2 1 #6 THWN-2 NEUTRAL 3/4" EMT CONDUIT NOT USED 2 #6 L1,L2 THWN-2 1 #6 THWN-2 NEUTRAL 1 #8 THWN-2 GROUND 3/4" EMT CONDUIT NEMA3R JUNCTION BOX PV INTERCONNECTION POINT - LINE SIDE SE5000H-US BY SOLAREDGE REFER TO D-3 SHEET (13) Q. PEAK DUO BLK ML-G10+395 BY Q. CELL REFER TO D-1 SHEET WIRE SIZES, QUANTITY & TYPE RACEWAY SIZE, TYPE, LOCATION & INFO.WIRE AMPACITY CALCULATIONS ADDITIONAL INFORMATION WIRE TAG CONDUCTOR QTY. SIZE & TYPE NEUTRAL QTY. SIZE & TYPE GROUND QTY. SIZE & TYPE RACEWAY SIZE & TYPE RACEWAY LOCATION RACEWAY HEIGHT ABOVE ROOF OUTPUT CURRENT 125% OF OUTPUT CURRRENT MIN OCPD WIRE DE-RATED CALCULATION DIST.VOLTAGE VOLTAGE DROP % CONDUIT FILL %WIRE RATING AMBIENT TEMP # OF COND. FINAL AMPACITY DC (BEFORE JB) DC (AFTER JB) AC (INVERTER TO METER) (4) #10 AWG PV WIRE (4) #10 AWG THWN-2 (2) #6 AWG THWN-2 N/A N/A (1)#6AWG THWN-2 (1) #8 AWG BARE COPPER (1) #8 AWG THWN-2 (1) #8 AWG THWN-2 NOT APPLICABLE 3/4" EMT CONDUIT 3/4" EMT CONDUIT UNDER ARRAY ABOVE ROOF EXTERIOR WALL 1/2" TO 3-1/2" 1/2" TO 3-1/2" "N/A" 15A 15A 21A 18.8A 18.8A 26.25A 20A 20A 30A 40A X 0.76 X 1 = 30.4 A 40A X 0.76 X 0.8 = 24.3 A 40A X 0.76 X 1 =30.4 A 10 FT. 20 FT. 5 FT. 350V 350V 240V 0.11% 0.21% 0.1% 6.4% 8.1% 7.7% OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC ONE LINE RISER DIAGRAM E-1 3 ONE LINE RISER DIAGRAM1N.T.S. 1 1 UPDATED LAYOUT AS REQUESTED1 1-28-22 JH NT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.13 (B) LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: NEC 110.27 (C) OSHA 1910.145(f)(7) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL DO NOT DISCONNECT UNDER LOAD WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING: PHOTOVOLTAIC POWER SOURCE CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SYSTEM SHUTDOWN MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 690.15, NEC 690.13(B) WARNING SECOND SOURCE IS PHOTOVOLTAIC SYSTEM DUAL POWER SOURCE PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 21 A 240V MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 480 VDC 13.5 A INVERTER #1 240 V 60 HZ MAXIMUM AC POWER NOMINAL OPERATING AC FREQUENCY MAXIMUM AC CURRENT NOMINAL OPERATING AC VOLTAGE 5.0 KW 21 A MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION N/A 15 A LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.13 (B) LABEL LOCATION: MAIN SERVICES DISCONNECT, DC CONDUIT PER CODE: NEC 690.31 (G) (3) LABEL LOCATION: INVERTER PER CODE: NEC 690.53 LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.54 LABEL LOCATION: INVERTER PER CODE: NEC 690.52 LABEL LOCATION: MAIN SERVICE PANEL PER CODE: NEC 690.45(B)(5) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12 (B)(3) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12(B)(2)(3)(b) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 690.33(E)(2) & NEC 690.15 (C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: NEC 690.56(C)(3) LABEL LOCATION: AC DISCONNECT POINT OF INTERCONNECTION PER CODE: NEC 690.56(C) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. EMERGENCY RESPONDER THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: FFPC 7TH EDITION: 11.12.2.1.1.1.1 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN THE ENTIRE PV SYSTEM. LABEL LOCATION: ADJACENT TO MAIN DISCONNECT CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS SUPPLY SIDE SAFETY LABELS E-2 4 OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC PV SAFETY LABELS DATA1N.T.S. SOLAR MODULE - TYP. SEE D-1 ROOF MOUNTS LOCATED AT CENTER OF ROOF TRUSS - TYP. WOOD TRUSSES/RAFTERS LOCATION - INSTALLER MUST VERIFY IN FIELD ARRAY A TILT=18º AZIMUTH= 182º (S) NORTH PV STRING INVERTER #1 PV DISCONNECT EXISTING ELECTRIC METER OBS OBS OBS OBS OBS 3' 3' FLAT A1.1 A1.7A2.1 A2.6 EXT. EXT.EXT. EXT.EXT. 73.97" 41.14" NOTES: -INSTALL MID CLAMPS BETWEEN MODULES AND ENDS CLAMPS AT THE END OF EACH ROW OF MODULES. -ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE. Q.PEAK DUO BLK ML-G10+ 395W UL 1703 CERTIFIED MAX. DESIGN LOAD: 83.54 psf APPLIED WIND LOAD : 30.08 psf - - - - ULTIMATE WIND SPEED 175 mph DESIGN WIND SPEED 157 mph RISK CATEGORY II EXPOSURE CATEGORY B ROOF SLOPE (°)18 ROOF TYPE HIPPED MATERIAL ROOF TYPE PRESSURE ZONE:1&2 MEAN ROOF HEIGHT:10.5 PERIMETER WIDTH:3.0 KD 0.85 KZT 1.00 KH 0.575 VELOCITY PRESSURE (q) = 0.60*0.00256* KHKZTKDV2 VELOCITY PRESSURE (ASD)18.50 INTERIOR EDGE FACTOR: E = 1.0 EXTERIOR EDGE FACTOR: E = 1.5 ARRAY EQUALIZATION FACTOR: a =0.8 EXTERNAL PRESSURE COEFFICIENT Z1 0.7 -1.3 EXTERNAL PRESSURE COEFFICIENT Z2e 0.7 -1.8 EXTERNAL PRESSURE COEFFICIENT Z2r 0.7 -2.4 EXTERNAL PRESSURE COEFFICIENT Z3 0.7 -1.8 INTERNAL PRESSURE COEFFICIENT 0.18 ZONES PRESSURES (PSF) INTERIOR PRESSURES (PSF) EXTERIOR PRESSURES (PSF) MAX SPAN (FT) MAX CANTI- LEVER (IN) 1 27.37 -19.24 -28.86 4 16 2e 36.62 -26.64 -39.96 4 16 2r 47.72 -35.52 -53.28 4 16 3 36.62 -26.64 -39.96 4 16 TOTAL ROOF AREA 1,722.18 sq.-ft TOTAL MODULES:13 TOTAL PHOTOVOLTAIC AREA:274.57 sq.-ft WIND LOAD (PSF):30.08 TOTAL WIND LOAD (LBS):8,259.07 TOTAL ROOF MOUNTS:48 TENSION FORCE PER MOUNT (LBS):172.06 ' ' ' ' " " " " TIN WORST CASE MODULE: ZONE 1: 89% ZONE 2e: 11% 28.86(0.89) + 39.96(0.11) =30.08psf OBS ROOF OBSTRUCTIONS PV MODULES TRUSSES OR RAFTERS ROOF MOUNTS ROOF SLOPE XX.X ARRAY # STRING # MODULE # & RAIL EXTERIOR PV MODULEEXT. STRUCTURAL PLAN S-1 5 OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC STRUCTURAL ROOF PLAN & PV MODULES LAYOUT1N.T.S. SOLAR MODULE ROOF INSPECTION NOTE: PV MODULE IN LAYOUT IS CONSIDERED NON-EXPOSED AFTER COMPLYING WITH THE FOLLOWING STATEMENTS BASED ON ASCE7-16: -NO INDIVIDUAL PV MODULE IS MORE THAN 0.5(MEAN ROOF HEIGHT) AWAY FROM ROOF EDGE OR ANOTHER MODULE. -NO INDIVIDUAL PV MODULE IS MORE THAN 4 FT AWAY FROM ROOF EDGE OR ANOTHER MODULE. -INDIVIDUAL PV MODULE IS MORE THAN 1.5(MODULE LENGTH) AWAY FROM CLOSEST EXPOSED EDGE ASCE 7.16 - 29.4-7 DESIGNED WIND PRESSURES: p = qh (GCp)(E)( a) ROOF'S GENERAL NOTES: 1- CONTRACTOR/INSTALLER TO VERIFY ROOF CONDITIONS FOR PROPER INSTALLATION OF THE PV SYSTEM. 2- CONTRACTOR/INSTALLER TO NOTIFY THE OWNER IMMEDIATELY OF ANY ROOF DEFICIENCIES AND/OR REPAIR REQUIRED TO INSTALL THE PV SYSTEM. 3- EOR DOES NOT ASSUME ANY RESPONSIBILITY FOR THE INSTALLATION OF ANY PV SYSTEM ON DEFICIENT ROOFS. 4-CONTRACTOR/INSTALLER ASSUMES ALL RESPONSIBILITY TO INSTALL AS PER MANUFACTURER STANDARDS. WEIGHTED AVERAGE LEGEND & SYMBOLS 1 1 UPDATED LAYOUT AS REQUESTED1 1-28-22 JH NT METAL ROOF MOUNT DETAIL & DATA1 N.T.S. Notes: (1) Thread must be embedded in the side grain of a Trusses or other structural member integral with the building structure. (2)Lag Bolts must be located in the middle third of the structural member. (3)These values are not valid for wet services. (4)This table does not include shear capacities. If necessary, contact a local engineer to specify lag bolt size with regard to shear forces. (5)Install lag bolts with head ad washer flush to surface (no gap). Do nor over-torque. (6)Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary. S-5 BRACKET PULL OUT CALCULATIONS DISTRIBUTED LOAD CALCULATIONS PV MODULES & RACKING WEIGHT = (INDIVIDUAL MODULE WEIGHT + 3.5 LBS) * (MODULE QTY) = (52 LBS) * (13) = 676 LBS PER SQUARE FEET (PSF) ARRAY LOAD = PV MODULES & RACKING WEIGHT / TOTAL ARRAY AREA = 676 LBS / 274.57 SQFT = 2.46 PSF HENCE, ROOF WILL CARRY THE ADDITIONAL SOLAR SYSTEM LOAD K2 CROSSRAIL STANDARD RAIL SOLAR MODULE 5/16" Ø - 18 X 1 - 1/4" S.S. FLANGE BOLT L FOOT S-5-SOLARFOOT ATTACHEMENT <25% MODULE LENGTH TYP. "A"CROSSRAIL YETI END CLAMP 13MM HEX BOLT LOCK WASHER Spruce, Pine,Per inch Thread Depth 266lbs SS Lag Bolt 5/16" x 4"Min. Thread Depth 0'-3" Wood Strength x Thread Depth = Pull Out Strength 266 lbs. x 3 in = 798 lbs. Allowable Pull Out Strength per Lag Bolt 798 lbs. Max. Pull Out Strength Required per Lag Bolt 168.55 Lag Bolt Pull Out Strength Safety Factor 4.73 K2 SYSTEM 44-X Landscape 72-Cell Ground Snow Load Exposure Category Panel Angle Wind Speed 160 mph Roof Zone 1'1 2e 2r 2n 3e 3r 0 psf B 7 to 20 Array Interior 73 73 73 64 64 64 60 Array Edge 64 64 64 54 54 54 49 OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC RACKING PLAN S-2 6 UPDATED LAYOUT AS REQUESTED1 1-28-22 JH NT 1 PV MODULES DATA SHEET D-1 7 OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC SMART MONITORING DATA SHEET D-2 8 OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC INVERTER DATA SHEET D-3 9 OF 9 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 ISABELLA DICHARD 11-15-21 6709 SANTA CLARA BLVD FORT PIERCE, FL 34951 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 1301-611-0380-000-0 PARCEL NUMBER: PROJECT ID: TSP106239 DOCUMENT CONTROL 11-17-21 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC TS DM DATE CAD QC