Loading...
HomeMy WebLinkAboutBUILDING PLAN�-- - - 20-14' 3'-0" 16'-1O3� ; s FRAME I O 'CA \ .. - OE CIDSUPPORTING I (/ �I®P►� i `a 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND �� M , CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, �0���` i INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS i ARE THE RESPONSIBILITY OF OTHERS. �O �� O"0 I 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY I ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS �1 I LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE i RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. R0LL1UP M-15. , 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003i 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE DOOR I . i CODE INFORMATION CODE VERSION FABCE2� 0 67th Edition MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE Y STRUCTURE CONSTRUCTION TYPE II—B II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. + — 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 0PSF OR 3001b P.L. �`� RESPONSIBILITY OF THE OWNER. I 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. i 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED �OF�EACH POST/ RUSS ALONG ANCHOR HSIDES WELDER. I AND EVERY OTHER END —WALL POST 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,50OLB TENSILE STRENGTH. 10. 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. 2" MIN. BASE RAIL , ; FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,200 SQ. FT. o I � O GRAD _ . i N° i I I �III—) I'� ° 2,500 PSI 4" CONCRETE SUB —GRAD SO LS: SLAB WITH 10GA. W.W.F. —TOBE TER ITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION ' '°R318 AND 1816 OF THE 2020 FLORIDA BUILDING CODE, 7TH EDITION OR FIBER MESH NOTES:/MINIMUIM —BOTTOM OF CONCRETE FOOTING SHALL BE MINIMUM OF 12"BELOW UNDISTURBED OR (2) #5 REBAR ® 6" O.C.o ENGINEERED GRADE SOIL BEARING CONTINUOUS WITH MINIMUM FRAME CONCRETE: CAPACITY 500 PSF TYP. OJT -MINIMUM 2,600 PSI COMPRESSIVE STRENGTH AT 28 DAYS _ ( ) 25" OVERLAP SPLICE —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE I� DESIGNED TO SLOPE AWAY FROM THE STRUCTURE I REINFORCING STEEL (REBAR) REQUIREMENTS: CONCRETE FOUNDATION / OAS E RAIL —MINIMUM GRADE 40 STEEL ANCHOR DETAIL I —REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: I REVISIONS REV DESCRIPTON DATE BY 1 FRAME OUT's 1 /3/22 MTB DRAWN NITSt�] 11/23/21 —THE REBAR IS BENT COLD ; —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED i LOCATION: 5115 Palmetto Dr, Fort Pierce SIZE. 40'L X 30'W X 12'H 6—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. —COVER: —3" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY i ' IN CONTACT WITH SOIL OR WEATHER, AND 1j" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF-}" FOR FINE ROLL-1 UP O O GROUT, AND }" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. DOOR REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 11" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: —METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, ' CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. O i MIN. 2,500 PSI 4" CONCRETE SLAB WITH 1013A. W.W.F. (OR Q 22 FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER 12"x12" REINFORCED FOOTER I L------------------------------------------------------------------------------------------------------------------------ _------ -_____-----___---______________--___�NOING--------------------------------------------- -----J w / DOOR j MattheW T. BaldWin P.E. 28' " 3'-0" '-1 j 1" -0�4 - 40'-0" z Florida License #64608 Sheet- CA-1 OF 4 LEFT SIDE WALL RIGHT SIDE WALL SWINGING DOOR CODE VERSION F13C 2020 7th Edition ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM INONE INTERNAL PRESSURE COEFF, IMPORTANCE FACTOR ROOF DEAD LOAD ROOF LIVE LOAD FLOOR DEAD LOAD FLOOR LIVE LOAD "R"RATING OF WALLS,FLOOR, MODULES PER BUILDING HURRICANE PROTECTION US, HURRICANE SHELTER USAGE OUT's U +/— 0.18 1.0 IOPSF ZOPSF OR 3001b P.L 10PSF 50PSF N/A 1 NO No 1,200 SQ. FT. DATE I BY MTB 11/23/21 5115 Palmetto Dr, Fort Pierce 40-L X 30-W X 12-H Lu o w Matthew T. Baldwin P.E. LLI Florida License #64608 0 Sheet: CA-3 CC f 4 MINIMUM 6" TS NIPPLE. NIPPLE + SECURED TO WALL POST WITH SC) RE 14xj" SELF —DRILLING NIPPLE TO (� BASE RAIL NIPPLE BASE F POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CUP SECURED WITH (4) #12-14)4" SELF -DRILLING SCREWS NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL INTERI( #12-14)4" SELF —DRILLING SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALLY EXTERIOR MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC) 12 14x4" SELF —DRILLING Ir 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14)j" SELF —DRILLING SCREWS 2"x2"x2" 16 GA. ANGLE CUP SECURED WITH (4) #12-14)" II1111-1 SELF —DRILLING SCREWS INTERMEDIATE POST TO END POST TO BASE RAIL HEADER/BASE RAIL/OR CONNECTION WINDOW RAIL DETAIL 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xj" SELF —DRILLING SCREWS VARIES MAX. SPACINGMIN. TSTD. " TsIPPLEO 7qg WALL xj"—f SCREWNG STD. MAX. SP CING VARIES SIDE WALL ROLL —UP DOOR/FRAME OUT POST TO TRUSS HEADER DETAIL CONNECTION PER MANUFACTURERS INSTRUCTIONS A3:AIPPLE TO #14x1" SELF —DRILLING SCREWS ® 6" O.C. MAX. & 6" MAX. FROM CORNERS DOOR FRAME TO POST CONNECTION ROLL —UP DOOR TO POST CONNECTION 1 "x2j" 16 GA. U—CHANNEL BRACE, MIN. 24" UP TO 7' POST, MIN. 48" OVER 7' POST. MIN. 45' TO MAX. 60' FROM HORIZ. (EXCLUDE END —WALLS). SECURED WITH (4)#12-14x4" SELF —DRILLING SCREWS. MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC)#12 14xj" SELF —DRILLING BOX EAVE RAFTER TO POST CONNECTION DETAIL Enclosed Design Pressures - 150 mph Basic Wind Speed Zone Roof Wall 1 2n 2r 2e 3r 3e 4 5 9.6 9.7 9.6 9.6 14.3 14.3 14.3 17.2 -11.1 -35.2 -28.1 -11.1 -61.5 1 -51.7 1 -16.0 -21.7 2"x2"x2" 16 GA. ANGLE CLIP SECURED' WITH (4) #12-14x4" SELF —DRILLING SCREWS SINGLE OR DOUBLETS HEADER CONNECTION DETAIL OPTION 1 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14xj" SELF-DRLLING SCREWS '2-1-2-1' (6" Q.C. (s" O.C. MAX.)) 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-141" SELF —DRILLING SCREWS TO EACH RAFTER. NIPPLE TRUSSED RAFTER CONNECTION DETAIL MINIMUM 6" TS NIPPLE. NIPPL SFcURED TO WALL POST WITH 12-14x4" SELF —DRILLING EWS SINGLE OR DOUBLETS HEADER HEADER CONNECTION DETAIL OPTION 2 APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL21450.3 SERIES 3100 i P 8 ILa fi I CODE VERSION IFBC 2020 7th Edition,11 BUILDING TYPE CONSTRUCTION TYPE RISK CATEGORY FIRE PROTECTION FIRE SUPPRESSION OCCUPANCY WIND SPEED STRUCTURE U INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,200 SQ. FT. urwnn nr: MTB DAM 11 /23/21 LOCATION: 5115 Palmetto Dr, Fort Pierce SIZE. 40'L X 30'W X 12'H ":j /'3,/ 122 �-y \` (n J Matthew T. Baldwin P.E. Q Florida License #64608 o Sheet- CA-4 OF 4