HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADAMS HOMES-1820 CR MODEL Builder Name: ADAMS HOMES Street: 8120 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1890.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1656.00 ft2 3. Number of units, if multiple family 1 b. Frame- Wood, Adjacent R=11.0 234.00 ft2 4. Number of Bedrooms 4 c. N/A d. N/A R= ft2 R= ft2 5. Is this a worst case? No 10. Ceiling Types (1820.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ft') 1820 a. Under Attic (Vented) b. N/A R=30.0 1820.00 ft2 R= ft, Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(199.3 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST R W 6 150 a. U-Factor: Dbl, U=0.33 139.33 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 60.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 27.0 HSPF:8.50 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.224 14. Hot water systems 8. Floor Types (1820.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features EF: 0.900 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.110 Total Proposed Modified Loads: 61.33 PASS Total Baseline Loads: 63.90 I hereby certify that the plans and specifications covered by Review of the plans and� Sys this calculation are in compliance with the Florida Energy specifications covered by this __ 0 Code. calculation indicates compliance=_= PREPARED BY: � � with the Florida Energy Code. 1-4 Before construction is completed DATE: 12-6-19 this building will be inspected forcompliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Energy Florida Statutes. ,S . Code.'c0�iJ� OWNER/AGENT '-- � BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist'in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY nwFrK1-IS6r RFanPT PROJECT Title: ADAMS HOMES-1820 CR MO Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1820 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8120 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1820 16380 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 2 130 1170 No 0 1 1 Yes Yes Yes 2 CLST 2 17 153 No 0 1 Yes Yes Yes 3 BATH 2 54 486 No 0 1 Yes Yes Yes 4 BEDROOM 3 130 1170 No 0 1 1 Yes Yes Yes 5 CLST 3 27 243 No 0 1 Yes Yes Yes 6 AHU CLST 12 108 No 0 1 No Yes Yes 7 DINING ROOM 220 1980 No 0 1 Yes Yes Yes 8 BEDROOM 4 161 1449 No 0 1 1 Yes Yes Yes 9 CLST 4 21 189 No 0 1 Yes Yes Yes 10 FOYER 48 432 No 0 1 Yes Yes Yes 11 LAUNDRY 49 441 No 0 1 No Yes Yes 12 KITCHEN 262 2358 Yes 0 1 Yes Yes Yes 13 FAMILY ROOM 264 2376 No 0 1 Yes Yes Yes 14 HALL 32 288 No 0 1 No Yes Yes 15 O BATH 131 1179 No 0 1 Yes Yes Yes 16 O WIC 38 342 No 0 1 No Yes Yes 17 OWNERS BEDRO 224 2016 No 0 1 1 Yes Yes Yes 12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPIIT SI IMMARV rWGrkl lie-- DCnnn-r FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 2 33 ft 0 130 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 17 W ____ 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 54 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 3 10 ft 0 130 ft2 -___ 1 0 0 5 Slab -On -Grade Edge Insulation CLST 3 3 ft 0 27 ftz ____ 1 0 0 6 Slab -On -Grade Edge Insulation AHU CLST 1 ft 0 12 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation DINING ROOM 11 ft 0 220 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation. BEDROOM 4 24 ft 0 161 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation CLST 4 8 ft 0 21 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation FOYER 6 ft 0 48 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 49 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 16 ft 0 262 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation FAMILY ROOM 13 ft 0 264 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 32 ft2 ___- 1 0 0 15SIab-On-Grade Edge Insulation 0 BATH 11.9 ft 0 131 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation 0 WIC 1 ft 0 38 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation OWNERS BEDR 40 ft 0 224 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2035 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC / v Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 W N N 12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHFCKI I-RT RIFPnRT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 2 30 Blown 130 ftZ 0.1 Wood 2 Under Attic (Vented) CLST 2 30 Blown 17 ftZ 0.1 Wood 3 Under Attic (Vented) BATH 2 30 Blown 54 ft2 0.1 Wood 4 Under Attic (Vented) BEDROOM 3 30 Blown 130 ftZ 0.1 Wood 5 Under Attic (Vented) CLST 3 30 Blown 27 ftZ 0.1 Wood 6 Under Attic (Vented) AHU CLST 30 Blown 12 ftZ 0.1 Wood 7 Under Attic (Vented) DINING ROOM 30 Blown 220 ftZ 0.1 Wood 8 Under Attic (Vented) BEDROOM 4 30 Blown 161 ftZ 0.1 Wood 9 Under Attic (Vented) CLST 4 30 Blown 21 ftZ 0.1 Wood 10 Under Attic (Vented) FOYER 30 Blown 48 ftZ 0.1 Wood 11 Under Attic (Vented) LAUNDRY 30 Blown 49 ftZ 0.1 Wood 12 Under Attic (Vented) KITCHEN 30 Blown 262 ftZ 0.1 Wood 13 Under Attic (Vented) FAMILY ROOM 30 Blown 264 ftZ 0.1 Wood 14 Under Attic (Vented) HALL 30 Blown 32 ftZ 0.1 Wood 15 Under Attic (Vented) 0 BATH 30 Blown 131 ftZ 0.1 Wood 16 Under Attic (Vented) 0WIC 30 Blown 38ft2 0.1 Wood 17 Under Attic (Vented) OWNERS BEDR 30 Blown 224 ftZ 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 S Exterior Concrete Block - Int InsuBEDROOM 2 4.1 10 0 9 0 90.0 ftZ 0 0 0.6 0 2 N Exterior Concrete Block - Int InsuBEDROOM 2 4.1 10 0 9 0 90.0 ftZ 0 0 0.6 0 3 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 13 0 9 0 117.0 ftZ 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 9 0 18.0 ftZ 0 0 0.6 0 5 N Exterior Concrete Block - Int Insul BATH 2 4.1 6 0 9 0 54.0 ftZ 0 0 0.6 0 6 N Exterior Concrete Block - Int InsuBEDROOM 3 4.1 10 0 9 0 90.0 ftZ 0 0 0.6 0 7 N Exterior Concrete Block - Int Insul CLST 3 4.1 3 0 9 0 27.0 ftZ 0 0 0.6 0 8 N Exterior Concrete Block - Int InsUDINING ROO 4.1 11 0 9 0 99.0 ftZ 0 0 0.6 0 9 W Exterior Concrete Block - Int InsuBEDROOM 4 4.1 11 0 9 0 99.0 ftZ 0 0 0.6 0 10 N Exterior Concrete Block - Int InsuBEDROOM 4 4.1 13 0 9 0 117.0 ftZ 0 0 0.6 0 11 S Exterior Concrete Block - Int Insul CLST 4 4.1 5 0 9 0 45.0 ftZ 0 0 0.6 0 _ 12 W Exterior Concrete Block - Int Insul CLST 4 4.1 3 0 9 0 27.0 ftZ 0 0 0.6 0 13 W Exterior Concrete Block - Int Insul FOYER 4.1 6 0 9 0 54.0 ftZ 0 0 0.6 0 14 S Garage Frame- Wood FOYER 11 6 0 9 0 54.0 ftZ 0 0.1 0.6 0 15 W Garage Frame- Wood LAUNDRY 11 7 0 9 0 63.0 ftZ 0 0.1 0.6 0 16 S Exterior Concrete Block - Int Insul KITCHEN 4.1 16 0 9 0 144.0 ftZ 0 0 0.6 0 17 W Garage Frame - Wood KITCHEN 11 13 0 9 0 117.0 ftZ 0 0.1 0.6 0 18 E Exterior Concrete Block - Int InsL FAMILY ROO 4.1 13 0 9 0 117.0 ftZ 0 0 0.6 0 19 S Exterior Concrete Block - Int Insul 0 BATH 4.1 12 0 9 0 108.0 ftZ 0 0 0.6 0 20 S Exterior Concrete Block - Int InsLOWNERS BE 4.1 16 0 9 0 144.0 ftZ 0 0 0.6 0 21 N Exterior Concrete Block - Int InsLOW NERS BE 4.1 10 0 • 9 0 90.0 ftZ 0 0 0.6 0 _ 22 E Exterior Concrete Block - Int InsLOW NERS BE 4.1 14 0 9 0 126.0 ftZ 0 0 0.6 0 12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev., 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPIIT -R1IMMARV r-1-IFrkl 1cT QGDr%DT DOORS # Ornt Door Type Space Storms U-Value Ft Width In Height Ft In Area 1 2 SE NW Insulated FOYER None Insulated FAMILY ROO None .39 3 .39 2 8 6 8 6 8 20 ft2 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / V/ # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 10 E 3 Vinyl N 6 Vinyl N 8 Vinyl W 9 Vinyl W 13 Vinyl S 16 Vinyl E 18 Vinyl S 19 Vinyl S 20 Vinyl E 22 Vinyl Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.33 0.23 N 0.33 0.23 N 0.33 0.23 N 0.33 0.21 N 0.33 0.23 N 0.33 0.23 N 0.33 0.21 N 0.33 0.23 N 0.33 0.23 N 0.33 0.23 N 15.0 ft2 2 ft 0 in 15.0 ft2 2 ft 0 in 30.0 ft2 2 ft 0 in 30.0 W 2 ft 0 in 13.3 ft2 2 ft 0 in 30.0 ft2 2 ft 0 in 30.0 ft2 2 ft 0 in 6.0 ft2 2 ft 0 in 15.0 ft2 2 ft 0 in 15.0 ft2 2 ft 0 in 0 ft 6 in 0 ft 6 in 0 ft 6 in 0 ft 6 in 0 ft 4 in 0 ft 6 in 0 ft 0 in 0 ft 6 in 0 ft 6 in 0 ft 6 in None None None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1911 104.91 197.3 .1454 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15 35 kBtu/hr 1050 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60.9 gal 120 deg None 12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHFmi iRT RFPnRT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Heating Jan Feb Mar A r Mar f Apr f Ma May Jun Jul Jun f Jul Auge f AuSep Oct f Oct Nov Nov Dec f X� Dec Venting Jan Feb Mar [X] Apr [ May Jun [ Jul [ Aug Se [X] Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 78 78 78 78 78 80 80 80 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 80 78 80 78 80 78 78 78 78 78 80 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM PM 65 68 65 68 65 68 65 68 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 65 68 65 65 65 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. fe ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft, ft 0.3 0 BATH Default(8lbs/sq.ft. ft2 ft 0.3 0 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 OWNERS BEDRO 12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ADAMS HOMES-1820 CR MODEL Builder Name: ADAMS HOMES Street: 8120 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including above -garage maintain permanent contact with the underside of and cantilevered floors) subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an J plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Iates and walls or ceilin s. a- In wiriitinn incnzctinn of Inn wollc -- --- ..._r __._.. _. .-I ..,.....—,— — — wnu L— IJiUVIWUIIA VI Il+li'4VV. 12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition I. New (From Plans) 12. Ducts, location & insulation level 2. Single-family or multiple -family 2. Single-family a) Supply ducts R 6.0 b) Return ducts R 6.0 3. No. of units (ifmultiple-family)3. 1 c) AHU location AHU CLST 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 5. Is this a worst case? (yes/no) 5. No a) Split system SEER 15.0 b) Single package SEER 6. Conditioned floor area (sq. ft.) 6. 1820 c) Ground/water source SEER/COP d) Room unit/PTAC EER 7. Windows, type and area e) Other a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.224 14. Heating system: Capacity 27.0 c) Area 7c. 199.3 a) Split system heat pump HSPF 8.5 8. Skylights b) Single package heat pump HSPF a) U-factor:(weighted average) 8a. NA c) Electric resistance COP d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 9. Floor type, insulation level: f) Other a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 10. Wall type and insulation: b) Gas fired, natural gas EF c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 11. Ceiling type and insulation level 16. HVAC credits claimed (Performance Method) a) Under attic 11a. 30.0 a) Ceiling fans b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature•' --- Date: Address of New Home: 8120 AMALFI CIRCLE City/FL Zip: FORT PIERCE, FL 12/6/2019 11:48:44 AM EnergyGauge®'USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: ST LUCIE COUNTY Permit #: , ^i'k" Y.: Tb3 P° V� t� x\`.w 3+Y"`1F°k^5.,sssC' y ROM i .tf a, n .t 5, 4i h;.' �Ifi7yta' .`3' yam"" Y esa. Job�Ino a>o R���ti�_�,K �r4' �� Builder: ADAMS HOMES Community: Lot: NA Address: 8120 AMALFI CIRCLE City: FORT PIERCE State: FL Zip: s,.a • . "� �. a. �:aer... gyp. ` }.���?o-'".-�`ti�: �'�' .7�r�^�t",..x-,+,.�`a. ;T.�p.� Y�3�;�'^'Y4,C�2'e��h..n3.aG'i'�i.',k*�"eH�"y .fT�,`�tF��... <". �"-,�`S' �rAi rf,Leakage�TestR@SUItS,,,.�{�Passtt?gjresu/ts�must meetgetiher-the�Perfo�r fiance �PreS " `��� "� •"' �'��� S :�' ._ . y�` },�,��; „��,� � �. ,�.t�-'����'� ��z�� ,,,,, •F:� ��� a� ��. �5�., �.�,�-' � tk r-n��-�R er�pftve,�or�ERl�Method �.��� ���.ti#, v.±$��� :'�..�'�'�``�' ,-�is,�r -. ,4�. � �.,Ay`�'"�` a:,���+�4+�C'�,�.:�,2�, Ci L+,.,}y4}�-a+ h.,,•.. „Ts nt i sn �,": �' �.,�,S��i3 �,a 4i. ',.h�S. �nF.'-�ii �'�s;'��+*`raul`" :^s��r�n.:7",>tr�,2 �?t .'A+v�...?..,f�.a.`-ui •n,C:3r�/a.i+�.,t� ..x.."ee�,=,Lao"L.K wx 3a".;Fk'a'�S,rcisy�4�'vk5ia`h�M1±�`+��»� °���kc'A'�}� ��'AA4"p'Y�3l�uC� ��'�1 ��,�i h�«'�..�n�ta`"'{��..Rt.�iaf :.i'CL�S �O".�'s'.1'Y'f! �,.Aa.'�cF . -S-r v.:.h`li='"�}'�i'*`�' �i..+f:H4-�n'7ia+'Z'�*r.7 �, Wtl� � {r'�,��� �r�k "�'�'T��'O}R'�..�`c��A `{�i%f 'T•�. .4ilfi�c�.���.�4�� "$�'�jM1 ��v'4 eYr ��.�aF��fR2l ;y}tsa'��F':'-.�+?sY,�.^.:.., M6 .fir. � �PRESCRIP�T�.1,1/E�MET,HOD�Thebuildrng.ortdwellrng urntsfiall betestedand.verified+as:haut gran atr.feaka a [afeof�notexceedrn �-� . �7,ar � � , s��,���changespe�r7h;�o*ur at a;pressure'`of 0 2rinctw g��50,Pascals.)rm Clrmate:Zones�t tlanc�42: ��-�� -� .'` �.�.'i �, � r�s-S�f�; -'�� `'��"+.F``tfk",��'rS'e�y'k".em..�j'4.E�+q'�2C''z�,'�y` "`E'>i�^= '.',.31.��. F `�'�fi5`:. :ram y an=:i �,..�:s*yetN �..r �' Srvi bi:ttll''`.(/ "c°a`•'c. � +- �V�.. a,=? 3P"s:5 '`:) s.{ � 't�3."i' � �Y•Ytv...c�CT"n�A. ��. v-� 2i 4F i! �ee' L Y' i,.M 3� � S .. '3'u I�� 4i"�<F5�\4a-`e. tl, v#,�"�+M'. X\;l•�,� $ u Q: ORMANCEor�El�IMETHODr�he.bwltlrn ,or4dwelhn unrt.sftallbettested ndYye fiedasshavrnah:arr(eaka ""-"= S s:h r WSJ r , 9= x Kg�..r � r- r 9e rate of not exceedrn the selectedACiC5Q) value as shown,oO Form'R405-2017� I?erFormance ortR4Q.6 20A7 :ER.x x {xu( ) k( sewn labeled as3mfiltration, st7bysectroq: u. 3 . n „Ckfi50 t,�,tLy£ H( O�pecetl on ,Form R1405,207 Energy Cal(Performance),or R406-2017 (RR 1 r 7.000"� A x 60 _ 16380 — Method for calculating buildinq volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at anytime after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. /� �.�y )1 �i€.'.t�`',V'� :n�* �',���3.�15'ti'y ram{ ���nvLYi"' }�.-..,� ��" r _fi�2' tIYN-','�\� t l�" Li.�v hR'.. :.fir" �x..f T�"'y� _<• "'ba : ..1 i"*' + 4"�.5,4 '� 's,..�" ?e4*�-�-.c�Y�-�) a.. �'�+�'�.5 '.�w�4�.�yY� 1�?��`.E� n"✓Sv, �..-..:.��v ..L.��. 7-.G ao: �:.:�-�,�"�Sa�'s,^^,���ra §s+,,*4.�,;e`.�„�n��.i_.::� �y� 4�,},,,`,��igwt�e�"^�°�`3 #�yy..�x-�� xy( ,..=�'tn 7''`�'� Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 12/6/2019 11:49:29 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1