HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance
Method
Project Name: ADAMS HOMES-1820 CR MODEL
Builder Name: ADAMS HOMES
Street: 8120 AMALFI CIRCLE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1890.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1656.00 ft2
3. Number of units, if multiple family 1
b. Frame- Wood, Adjacent
R=11.0 234.00 ft2
4. Number of Bedrooms 4
c. N/A
d. N/A
R= ft2
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1820.0 sqft.)
Insulation Area
6. Conditioned floor area above grade (ft') 1820
a. Under Attic (Vented)
b. N/A
R=30.0 1820.00 ft2
R= ft,
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(199.3 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU CLST
R W
6 150
a. U-Factor: Dbl, U=0.33 139.33 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 60.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
d. U-Factor: N/A ft2
13. Heating systems
kBtu/hr Efficiency
SHGC:
a. Electric Heat Pump
27.0 HSPF:8.50
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.224
14. Hot water systems
8. Floor Types (1820.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
EF: 0.900
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.110 Total Proposed Modified Loads: 61.33
PASS
Total Baseline
Loads: 63.90
I hereby certify that the plans and specifications covered by
Review of the plans and�
Sys
this calculation are in compliance with the Florida Energy
specifications covered by this
__ 0
Code.
calculation indicates compliance=_=
PREPARED BY: � �
with the Florida Energy Code.
1-4
Before construction is completed
DATE: 12-6-19
this building will be inspected forcompliance
with Section 553.908
I hereby certify that this building, as designed, is in compliance
with the Florida Energy
Florida Statutes.
,S .
Code.'c0�iJ�
OWNER/AGENT
'-- �
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist'in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY
12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY nwFrK1-IS6r RFanPT
PROJECT
Title:
ADAMS HOMES-1820 CR MO
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
1820
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle:
0
Street:
8120 AMALFI CIRCLE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
1820
16380
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BEDROOM 2
130
1170 No
0
1
1
Yes
Yes
Yes
2
CLST 2
17
153 No
0
1
Yes
Yes
Yes
3
BATH 2
54
486 No
0
1
Yes
Yes
Yes
4
BEDROOM 3
130
1170 No
0
1
1
Yes
Yes
Yes
5
CLST 3
27
243 No
0
1
Yes
Yes
Yes
6
AHU CLST
12
108 No
0
1
No
Yes
Yes
7
DINING ROOM
220
1980 No
0
1
Yes
Yes
Yes
8
BEDROOM 4
161
1449 No
0
1
1
Yes
Yes
Yes
9
CLST 4
21
189 No
0
1
Yes
Yes
Yes
10
FOYER
48
432 No
0
1
Yes
Yes
Yes
11
LAUNDRY
49
441 No
0
1
No
Yes
Yes
12
KITCHEN
262
2358 Yes
0
1
Yes
Yes
Yes
13
FAMILY ROOM
264
2376 No
0
1
Yes
Yes
Yes
14
HALL
32
288 No
0
1
No
Yes
Yes
15
O BATH
131
1179 No
0
1
Yes
Yes
Yes
16
O WIC
38
342 No
0
1
No
Yes
Yes
17
OWNERS BEDRO
224
2016 No
0
1
1
Yes
Yes
Yes
12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPIIT SI IMMARV rWGrkl lie-- DCnnn-r
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 2
33 ft
0
130 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
CLST 2
2 ft
0
17 W
____
1
0
0
3 Slab -On -Grade Edge Insulation
BATH 2
6 ft
0
54 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
BEDROOM 3
10 ft
0
130 ft2
-___
1
0
0
5 Slab -On -Grade Edge Insulation
CLST 3
3 ft
0
27 ftz
____
1
0
0
6 Slab -On -Grade Edge Insulation
AHU CLST
1 ft
0
12 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation
DINING ROOM
11 ft
0
220 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation.
BEDROOM 4
24 ft
0
161 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
CLST 4
8 ft
0
21 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
FOYER
6 ft
0
48 ft2
____
1
0
0
11SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
49 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
KITCHEN
16 ft
0
262 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
FAMILY ROOM
13 ft
0
264 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
HALL
1 ft
0
32 ft2
___-
1
0
0
15SIab-On-Grade Edge Insulation
0 BATH
11.9 ft
0
131 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
0 WIC
1 ft
0
38 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
OWNERS BEDR
40 ft
0
224 ft2
____
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2035 ft2
0 ft2 Medium
N
0.6 No 0.9
No
0
26.6
ATTIC
/
v Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
300
1820 W
N N
12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHFCKI I-RT RIFPnRT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BEDROOM 2
30
Blown
130 ftZ
0.1
Wood
2
Under Attic (Vented) CLST 2
30
Blown
17 ftZ
0.1
Wood
3
Under Attic (Vented) BATH 2
30
Blown
54 ft2
0.1
Wood
4
Under Attic (Vented) BEDROOM 3
30
Blown
130 ftZ
0.1
Wood
5
Under Attic (Vented) CLST 3
30
Blown
27 ftZ
0.1
Wood
6
Under Attic (Vented) AHU CLST
30
Blown
12 ftZ
0.1
Wood
7
Under Attic (Vented) DINING ROOM
30
Blown
220 ftZ
0.1
Wood
8
Under Attic (Vented) BEDROOM 4
30
Blown
161 ftZ
0.1
Wood
9
Under Attic (Vented) CLST 4
30
Blown
21 ftZ
0.1
Wood
10
Under Attic (Vented) FOYER
30
Blown
48 ftZ
0.1
Wood
11
Under Attic (Vented) LAUNDRY
30
Blown
49 ftZ
0.1
Wood
12
Under Attic (Vented) KITCHEN
30
Blown
262 ftZ
0.1
Wood
13
Under Attic (Vented) FAMILY ROOM
30
Blown
264 ftZ
0.1
Wood
14
Under Attic (Vented) HALL
30
Blown
32 ftZ
0.1
Wood
15
Under Attic (Vented) 0 BATH
30
Blown
131 ftZ
0.1
Wood
16
Under Attic (Vented) 0WIC
30
Blown
38ft2
0.1
Wood
17
Under Attic (Vented) OWNERS BEDR
30
Blown
224 ftZ
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
0
1
S
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
10
0 9
0
90.0 ftZ
0
0
0.6
0
2
N
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
10
0 9
0
90.0 ftZ
0
0
0.6
0
3
E
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
13
0 9
0
117.0 ftZ
0
0
0.6
0
4
N
Exterior Concrete Block - Int Insul CLST 2
4.1
2
0 9
0
18.0 ftZ
0
0
0.6
0
5
N
Exterior Concrete Block - Int Insul BATH 2
4.1
6
0 9
0
54.0 ftZ
0
0
0.6
0
6
N
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
10
0 9
0
90.0 ftZ
0
0
0.6
0
7
N
Exterior Concrete Block - Int Insul CLST 3
4.1
3
0 9
0
27.0 ftZ
0
0
0.6
0
8
N
Exterior Concrete Block - Int InsUDINING ROO
4.1
11
0 9
0
99.0 ftZ
0
0
0.6
0
9
W
Exterior Concrete Block - Int InsuBEDROOM 4
4.1
11
0 9
0
99.0 ftZ
0
0
0.6
0
10
N
Exterior Concrete Block - Int InsuBEDROOM 4
4.1
13
0 9
0
117.0 ftZ
0
0
0.6
0
11
S
Exterior Concrete Block - Int Insul CLST 4
4.1
5
0 9
0
45.0 ftZ
0
0
0.6
0
_ 12
W
Exterior Concrete Block - Int Insul CLST 4
4.1
3
0 9
0
27.0 ftZ
0
0
0.6
0
13
W
Exterior Concrete Block - Int Insul FOYER
4.1
6
0 9
0
54.0 ftZ
0
0
0.6
0
14
S
Garage Frame- Wood FOYER
11
6
0 9
0
54.0 ftZ
0
0.1
0.6
0
15
W
Garage Frame- Wood LAUNDRY
11
7
0 9
0
63.0 ftZ
0
0.1
0.6
0
16
S
Exterior Concrete Block - Int Insul KITCHEN
4.1
16
0 9
0
144.0 ftZ
0
0
0.6
0
17
W
Garage Frame - Wood KITCHEN
11
13
0 9
0
117.0 ftZ
0
0.1
0.6
0
18
E
Exterior Concrete Block - Int InsL FAMILY ROO
4.1
13
0 9
0
117.0 ftZ
0
0
0.6
0
19
S
Exterior Concrete Block - Int Insul 0 BATH
4.1
12
0 9
0
108.0 ftZ
0
0
0.6
0
20
S
Exterior Concrete Block - Int InsLOWNERS BE
4.1
16
0 9
0
144.0 ftZ
0
0
0.6
0
21
N
Exterior Concrete Block - Int InsLOW NERS BE
4.1
10
0 • 9
0
90.0 ftZ
0
0
0.6
0
_ 22
E
Exterior Concrete Block - Int InsLOW NERS BE
4.1
14
0 9
0
126.0 ftZ
0
0
0.6
0
12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev., 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPIIT -R1IMMARV r-1-IFrkl 1cT QGDr%DT
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Ft
Width
In
Height
Ft In
Area
1
2
SE
NW
Insulated FOYER None
Insulated FAMILY ROO None
.39 3
.39 2
8
6 8
6 8
20 ft2
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V/ #
Wall
Ornt ID Frame
Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
8
9
10
E 3 Vinyl
N 6 Vinyl
N 8 Vinyl
W 9 Vinyl
W 13 Vinyl
S 16 Vinyl
E 18 Vinyl
S 19 Vinyl
S 20 Vinyl
E 22 Vinyl
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
0.33 0.23 N
0.33 0.23 N
0.33 0.23 N
0.33 0.21 N
0.33 0.23 N
0.33 0.23 N
0.33 0.21 N
0.33 0.23 N
0.33 0.23 N
0.33 0.23 N
15.0 ft2 2 ft 0 in
15.0 ft2 2 ft 0 in
30.0 ft2 2 ft 0 in
30.0 W 2 ft 0 in
13.3 ft2 2 ft 0 in
30.0 ft2 2 ft 0 in
30.0 ft2 2 ft 0 in
6.0 ft2 2 ft 0 in
15.0 ft2 2 ft 0 in
15.0 ft2 2 ft 0 in
0 ft 6 in
0 ft 6 in
0 ft 6 in
0 ft 6 in
0 ft 4 in
0 ft 6 in
0 ft 0 in
0 ft 6 in
0 ft 6 in
0 ft 6 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ft2
400 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
1911 104.91 197.3 .1454
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Single HSPF:8.5
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow SHR
Block
Ducts
1
Central Unit/
Split
Single SEER: 15
35 kBtu/hr 1050 cfm 0.8
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap
Use SetPnt
Conservation
1
Electric
None Garage
0.9 50 gal 60.9 gal 120 deg
None
12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHFmi iRT RFPnRT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model #
Area Volume
FEF
None None
ft2
DUCTS
/ ---- Supply
----
---- Return ----
Air
CFM 25 CFM25
HVAC #
�/ # Location R-Value
Area Location
Area
Leakage Type
Handler
TOT OUT QN RLF
Heat Cool
1 Attic 6
150 ft2 Attic
15 ft2
Default Leakage
AHU CLST (Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan Feb
Heating Jan Feb
Mar A r
Mar f Apr
f
Ma
May
Jun Jul
Jun f Jul
Auge
f AuSep
Oct
f Oct
Nov
Nov
Dec
f X� Dec
Venting Jan Feb
Mar [X] Apr
[
May
Jun [ Jul
[ Aug
Se [X] Oct
Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
PM
78
80
78
78
78
78 78
78
78
80 80
80
80
80
80
80
78 78
78
78
78 78
78
78
Cooling (WEH) AM
PM
78
80
78
80
78
80
78
78 78
78
78
80 80
80
80
80
78 78
78
78
78 78
78
78
Heating (WD) AM
PM
65
68
65
68
65
68
65
68
65 65
65
68
68 68
68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
PM
65
68
65
65
65
65 65
65
68
68 68
68
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
fe
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft,
ft
0.3
0 BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
0 WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
OWNERS BEDRO
12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ADAMS HOMES-1820 CR MODEL Builder Name: ADAMS HOMES
Street: 8120 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
Owner: Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
=
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
above -garage
maintain permanent contact with the underside of
and cantilevered floors)
subfloor decking, or floor framing cavity insulation shall
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
J
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Iates and walls or ceilin s.
a- In wiriitinn incnzctinn of
Inn wollc
-- --- ..._r __._.. _. .-I ..,.....—,— — — wnu L— IJiUVIWUIIA VI Il+li'4VV.
12/6/2019 11:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
I. New (From Plans)
12. Ducts, location & insulation level
2. Single-family or multiple -family
2. Single-family
a) Supply ducts R 6.0
b) Return ducts R 6.0
3. No. of units (ifmultiple-family)3.
1
c) AHU location AHU CLST
4. Number of bedrooms
4. 4
13. Cooling system: Capacity 35.0
5. Is this a worst case? (yes/no)
5. No
a) Split system SEER 15.0
b) Single package SEER
6. Conditioned floor area (sq. ft.)
6. 1820
c) Ground/water source SEER/COP
d) Room unit/PTAC EER
7. Windows, type and area
e) Other
a) U-factor:(weighted average)
7a. 0.330
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.224
14. Heating system: Capacity 27.0
c) Area
7c. 199.3
a) Split system heat pump HSPF 8.5
8. Skylights
b) Single package heat pump HSPF
a) U-factor:(weighted average)
8a. NA
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
9. Floor type, insulation level:
f) Other
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.90
10. Wall type and insulation:
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 11.0
2. Masonry (Insulation R-value)
10B2.
11. Ceiling type and insulation level
16. HVAC credits claimed (Performance Method)
a) Under attic
11a. 30.0
a) Ceiling fans
b) Cross ventilation No
b) Single assembly
11b.
c) Whole house fan No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature•' ---
Date:
Address of New Home: 8120 AMALFI CIRCLE City/FL Zip: FORT PIERCE, FL
12/6/2019 11:48:44 AM EnergyGauge®'USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: ST LUCIE COUNTY Permit #:
,
^i'k" Y.: Tb3 P°
V� t� x\`.w 3+Y"`1F°k^5.,sssC' y ROM
i .tf a, n .t 5, 4i h;.' �Ifi7yta' .`3' yam"" Y esa.
Job�Ino a>o R���ti�_�,K
�r4'
��
Builder: ADAMS HOMES Community: Lot: NA
Address: 8120 AMALFI CIRCLE
City: FORT PIERCE State: FL Zip:
s,.a • . "� �. a. �:aer... gyp. ` }.���?o-'".-�`ti�: �'�' .7�r�^�t",..x-,+,.�`a. ;T.�p.� Y�3�;�'^'Y4,C�2'e��h..n3.aG'i'�i.',k*�"eH�"y .fT�,`�tF��... <". �"-,�`S'
�rAi rf,Leakage�TestR@SUItS,,,.�{�Passtt?gjresu/ts�must meetgetiher-the�Perfo�r fiance �PreS " `��� "� •"' �'��� S
:�' ._ . y�`
},�,��; „��,� � �. ,�.t�-'����'� ��z�� ,,,,, •F:� ��� a� ��. �5�., �.�,�-' � tk r-n��-�R er�pftve,�or�ERl�Method �.��� ���.ti#,
v.±$��� :'�..�'�'�``�' ,-�is,�r -. ,4�. � �.,Ay`�'"�` a:,���+�4+�C'�,�.:�,2�, Ci L+,.,}y4}�-a+ h.,,•.. „Ts nt i sn �,": �' �.,�,S��i3 �,a 4i. ',.h�S. �nF.'-�ii �'�s;'��+*`raul`" :^s��r�n.:7",>tr�,2
�?t .'A+v�...?..,f�.a.`-ui •n,C:3r�/a.i+�.,t� ..x.."ee�,=,Lao"L.K wx 3a".;Fk'a'�S,rcisy�4�'vk5ia`h�M1±�`+��»� °���kc'A'�}� ��'AA4"p'Y�3l�uC�
��'�1
��,�i h�«'�..�n�ta`"'{��..Rt.�iaf :.i'CL�S
�O".�'s'.1'Y'f! �,.Aa.'�cF . -S-r v.:.h`li='"�}'�i'*`�' �i..+f:H4-�n'7ia+'Z'�*r.7 �, Wtl� � {r'�,��� �r�k "�'�'T��'O}R'�..�`c��A `{�i%f 'T•�. .4ilfi�c�.���.�4�� "$�'�jM1 ��v'4 eYr ��.�aF��fR2l ;y}tsa'��F':'-.�+?sY,�.^.:.., M6 .fir.
� �PRESCRIP�T�.1,1/E�MET,HOD�Thebuildrng.ortdwellrng urntsfiall betestedand.verified+as:haut gran atr.feaka a [afeof�notexceedrn �-�
. �7,ar
� � , s��,���changespe�r7h;�o*ur at a;pressure'`of 0 2rinctw g��50,Pascals.)rm Clrmate:Zones�t tlanc�42: ��-�� -� .'` �.�.'i �, � r�s-S�f�;
-'�� `'��"+.F``tfk",��'rS'e�y'k".em..�j'4.E�+q'�2C''z�,'�y` "`E'>i�^= '.',.31.��. F `�'�fi5`:. :ram y an=:i �,..�:s*yetN �..r
�' Srvi bi:ttll''`.(/ "c°a`•'c. � +- �V�.. a,=? 3P"s:5 '`:)
s.{ � 't�3."i' � �Y•Ytv...c�CT"n�A.
��.
v-� 2i 4F i! �ee' L Y' i,.M 3� � S .. '3'u I�� 4i"�<F5�\4a-`e. tl, v#,�"�+M'. X\;l•�,�
$ u
Q: ORMANCEor�El�IMETHODr�he.bwltlrn
,or4dwelhn unrt.sftallbettested ndYye fiedasshavrnah:arr(eaka ""-"= S
s:h r WSJ r , 9= x Kg�..r � r- r 9e rate of not exceedrn
the selectedACiC5Q) value as shown,oO Form'R405-2017� I?erFormance ortR4Q.6 20A7 :ER.x
x {xu( ) k( sewn labeled as3mfiltration, st7bysectroq:
u. 3 . n „Ckfi50
t,�,tLy£ H( O�pecetl on ,Form R1405,207 Energy Cal(Performance),or R406-2017 (RR 1 r 7.000"� A
x 60 _ 16380 — Method for calculating buildinq volume:
CFM(50) Building Volume ACH(50)
O Retrieved from architectural plans
PASS
• Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at anytime after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
/� �.�y )1 �i€.'.t�`',V'� :n�* �',���3.�15'ti'y ram{ ���nvLYi"' }�.-..,� ��" r _fi�2' tIYN-','�\� t l�" Li.�v hR'.. :.fir" �x..f T�"'y� _<• "'ba : ..1 i"*'
+
4"�.5,4 '� 's,..�" ?e4*�-�-.c�Y�-�) a.. �'�+�'�.5 '.�w�4�.�yY� 1�?��`.E� n"✓Sv,
�..-..:.��v
..L.��.
7-.G ao: �:.:�-�,�"�Sa�'s,^^,���ra §s+,,*4.�,;e`.�„�n��.i_.::� �y� 4�,},,,`,��igwt�e�"^�°�`3 #�yy..�x-�� xy(
,..=�'tn 7''`�'�
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
12/6/2019 11:49:29 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1