Loading...
HomeMy WebLinkAboutLetter Truss Package Approval. y 249 Maitland Avenue, Suite 3000 Altamonte Springs, Florida 32701 F D P: (321)972-0491 1 F: (321)972-0484 1 E: info@fdseng.com Website: www.fdseng.com ENGINEERING ASSOCIATES December 10, 2019 Building Department Ref: Adams Homes Lot: Lot 28 Blk. 2 Subdivision: Waterstone Address: 8120 Amalfi Cir. Model: 2265 C RHG KA # 19-8300 Truss Company: Builders First Source Date of drawings: 12/9/19 Job No.: 2177638 Wind Speed: 160 Exposure: C Truss Engineer: Walter P. Finn To whom it may concern, We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, %`a,,« lolssot,s� eon JN5t'N No 87864 0 .p M'1 : •v lJ cy :• STATE OF ° �w 12/10/2019 Carl A. Brown, P.E. Luis'P '4Tgws3 C�1�.h" Todd M. Born, P.E60?1 FL. # 56126 FL. # �`��� �! A E '� �o �' FL. # 8212,� `�•PFIIS3i331�y "Doing Business with a Service Mindset and an Eye for etail" �7-0u-Gu 14-00-DO 23-04-00 19.08-00 7-00-00 1 0 ' 7-00-M U U U'll U U U C1 C1 0 0 b o C3 n 'pj m m r m U M m N m n m m m N 03 EXP SED 0 WI D Q Q Q N ❑ o 6 r` p In L� i m ❑ I I i I i i I Q- C3 0 0 b 05 CS JA IA a s m 00 03 a ro a m o_ m r Gri i i r w � E7V X E7VI3 E C T T 3 H3 H3 XPO E7 o 6 D TO IN N W H2 EXPOSED TO WIND HZ / a s 6 0 13-04-00 H4E 8-00-00 14-04-00 6-00-00 12-01-00 2-07-00 GX 22-00-00 57-00-00 !I SIMPSON CONNECTOR SCHEDULE ROOF TRUSS Q ID MODEL ROOF UPLIFT SYMBOL 0 1 A-11 LUS24 895 490 ILA' 3 A HTU26 3600 1555 ILA 0 B HTU28 4680 2140 ILB 0 C HTU26-2 13600 12175 1 1 LC 0 D 11 HTU28-2 4680 3485 1lD 0 E HGUS26-2 5320 2155 1 LE 0 F HGUS28-2 7460 3235 1 LF 0 G HGUS26-3 5230 2155 1 LG 0 H HGUS28-3 117460 113235 11 1lrt 0 J THJA-26 9100 114095 11 1 Li 32 11 3 X 8 NOP 1,4 REVIEWED REVIEWED WITH NOTATIONS ❑ REVISE AND RESUBMIT ❑ lSOT�VIEEWnEDD Corrections or comments made on equipment submittals or shop drawings during this review do not relieve con- tractor from compliance with requirements of the draw- ings and specifications. This check is only for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and corelating all quantities and dimen- sions, selecting fabrication pnxesses and techniques of construction, coordinating his work with that of all other trades and performing his work in a safe and satisfactory manner. rF1L RI A DESIGN SOLUTIONS, INC. Date �� BY Submittal Bo. Project No' Project Eng Project Name; VERIFY ALL DO&MIONS AND CEILING COMMONS PRIOR TO APPROVAL SOW CEIING FRANNG REOUIRED IN FIELD BY BULDER MAIN MD FORCE RESISTING SYSTEW- HYBRID YeNO AS. 4. ENOLOSED IMPORTANT EXPOSURE CATEGORY C OCCUPANCY CATEGORY I This Drawing Must Be Approved And LOAD PH WIND M N WIND LOAD '1FACTOR 1.00 Returned Before Fabrication Will TRUSSES HAVE BEEN DESIGNED FOR A 100 PSF BOTTOM CHORD UVE LOAD Begin. For Your Protection Check All NONCGNCURRENW WRH ANY OTHER LIVE LOADS Dimensions And Conditions Prior To Approval Of Plan. SIGNATURE BELOW INDICATES ALL ROOF LOADING FLOOR LOADING NOTES AND DIMENSIONS HAVE TCLL: 20 PSF TCLL: 40 PSF BEEN ACCEPTED. TCDL: 07 PSF TCDL: 10 PSF BCDL: 10 PSF BCDL: 5 PSF By Date TOTAL: 37 PSF TOTAL: 65 PSF DURATION: 1.26 DURATION: 1.00 CAUTIONHI DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-B1 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. lie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE. 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 0112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: 24" BUILDING CODE: FBC2017 BEARING HEIGHT SCHEDULE Hatch Legend L�I W BEARING BUILDER: Adams Homes PROJECT: Single Family MODEL: 2265 C 2C ADDRESS: 8120 AMALFI CIRCLE LOT / BLOCK: 2812 SUBDIVISION: CITY: I FT PIERCE DRAWN BY: K TEUBER JOB # : 1 2177638 DATE: 11210712019 1 SCALE: NTS PLAN DATE: 2019 REVISIONS: 1. 2. 3. 4. 6, ani� F IrsMtSoUr+ce 4408 Airport Road Plant City, FL 33563 Ph. (813) 306-1300 Fax (813) 305-1301