Loading...
HomeMy WebLinkAboutENGINEERING SUMMARY OF DESIGN FEATURESGOLDEN ENGINEERED 4 POST, 2 MOTOR SEA DRIVE BOAT LIFTS STRUCTURAL ENGINEERING REVIEW ` Ti-M CCWRICDD,N HAS DCEN DESGNEO AS A FAN%1'1M FORM RESSTCVGSYSTQJ.Y..1 N CACC=TEO GRAM ANDWND CLADS N=WLWNCFV M7HE,-LO.DA0=.N9CCCE. 7ftM1 =, 2C20. CHAPTEF1S 16 L 20, ADM 2015. AND ASCEW 7.15 TLNIIID OLW-NLOADr FOR 701'ATWLTANDTHEWADt.C1ADSA„ SOG'ATFD%VIH AN ULTIMATE Vi2Z SPFCD OF ICO ASH WC&LTZ •1r, RU CATEGORYI J L SlNDER31 PE R43 NDCONYM D: THE M NU:.ACTURNG, PEWORVAN CE.CA NSTALCAUONCF THS PRODUCT THMEG-NCRCSPEWLAT.C.+ %%VMENGN.%*MDLNA=FUANC\VM AOC"cP1Ep [N'aNEEii:.V3 PRACiCXS EASED O.V DATAPfr"I. YJFD RYhI R'A•CSA;7UR77 nG STRMTURAL REMEWS W7ED TO THC MFARYFRAV NGAMCON`'�CT'r V AIJ 6 NOT MENDED TO COVFA MECHMCAC AND ELECTR :AI.CC7JPCNFT{1S llfSEWECN^,AT.:V AIL'MEDONSTRUCTURALCALCLRATn'2 TRtID ilia-M1 F iRVT.I'FT,VA{:'HC6VfAN ACDITIC\AL DE5.5+IRFCt10iENENiS ANDCFATFR'A(NND/Ui=YA'V.Iiti1FLWFv-'CIEST 7HF BOAT LIFTS DEPxTED tN THESf SRECOICA1:G�ti 0.VD F1E1ATl':::CACbAADCh.l1,_Fti CN..Vw Fi.D AS LWp:FACi1LTD PRJBIICT FOR NOY�'TEGC-Ge;CI]+E'ANO t�TOREN�D TO COVERSITE SPECIRC CONNn=. REO1,Fa- FNT ANQC0.5T8nom LISTED LV L•C STRCTUFXCACCUTAT1Q1& - - J L Sa *,- PE ...15 Gr=R734 M1 W1 GA3ZW P.- 2=71-1S7B J1 SMtCEFS. P E COD F;- nx31Nc =, SIGNATURE NOT VALID %VFTHCUT RAISED SEAL PILE SPACING CHART The boat center of gravi needs to be set in the censer of the top beam UR Capachy 1' Dime °2' Dimension ec P 1� Diameettefs Lb. FL FL In. 5.005 11 B 7,500 10,000 y2 2 12.5 1 10 14.000 16.000 1 14 20.000 14 16 24.000 28.000 16 12 STAINLESS STEEL PILING MOUNT BRACKET- RECOAtMENDED ATTACK MENT BASED ON BRACKET CONFIGURATION. VERIFYADEOUAGY BASED ON ACTUAL SITE CONDITIONS: 4-w STAINLESS STEEL LAG.sCFt--hs USED TO CONNECT THEBRACKETSTOIHE HUNG AND 24W STAINLESS STEEL CARRIAGE BOLM LISEDTO CONNECT THE BRACKETS TO THE LIFT CHANNELS D D NOTE: THIS STRUCTURE HAS BEEN DESIGNED FOR. LOADSASSOCIATED WITH AN ULTIMATE WIND SPEED OF 180 MPH,IXPOSURE'D', RISK CATEGORY L CALCULATED PER FLORIDA BUILDING CODE 7th EDITION, 2020, ASCFJSE17-16 AND ADM-2015. BOATS SHALL NOT BE STORED ON LIF IS DURING HIGH WIND EVENTS. IN GENERAL, PILING PENETRATION TO BE A MINIMUM OF 10 INTO THE SAND BOTTOM OR S INTO THE ROCKSTRATA SUBSURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES. ALL PILINGS TO BE 2.5 C.CA PRESSURE TREATED WOOD. ALLSTRUCTURAL MEMBERS TO BE 6061-T6 ALUMINUM. SUMMARY OF DESIGN FEATURES O 0 0 0 000000 CAPACITY TOP BEAMCHANNEL CRADLE 1-BEAM 2EACH BUNK CABLE SIZELIFT CABLE GUIDE DRIVE WINDER MOTOR INCHES .RECOM 2EACH BOARDS (PIT SPREAD POST HGTH BRGS SHAFT OM VOLTAGE PER MIN SIZES Lbs LNG INCHES IN 6.QD0# 4Hx.15 2 W x 23 6Hx.19 4 W x29 107.75 3� ?20v RA 140'DAL 12D•LGTH x� one. 4_ 1b' x1PARST �T w � 240V/10A 39,70' 8.' D1A 1,500# SHx.15 225 Wx26 6Hx.19 4 Wx29 120.75 2-1HP 120 x 15.31 DAL 144' LGTH �¢ Q� a m � m . m S 1sv o MA 10,0D0# 6Hx.17 2.5Wx29 8Hx23 5Wx.35 2-3f4HP 120FA x 1531 OAL 150' LGTH Nf7J 4-56' ST 2 PART 116.75 m o, m 240V710A 19.8 14,0000 7Hx.17 23%1& 8Hx.25 5Wx.41 x 1w LGTH cc Lt1 c4 BHx.19 10Hx25 MOM# 3Wx.35 x153'CAL 6Wx.41 168'LGTH = � = �1 0 .,� Lu �ca 0 2-1 HP 120V�8A 10°DIA 20,00D# 8Hx.25 3.7510 x.41 10Hx25 6 W x.41 127.75 x 177 DAL 192° LGTH ;� 4 5 6° x 3I& _ - y 240 714A 8Hx.25 IBHx.29 24,000# 375Wx.41 6Wx.50 "v' 151.75 13.20' x 201 DAL 192' LGTH 10Hx.526 2.88 W x.437 12Hx.31 7 W x.62 4-5116' x60' ST ST 145 A LA40011150A 8.5i° .28,000# 12° DIA x 201 DAL 192' LGTH 4 PART Golden Manufacturing, Inc. 17611 East Street, N. Fort Myers Florida 33917 Pub 12/18/20 GOLDEN ENGINEERED 4 POST, 2 MOTOR SEA DRIVE BOAT LIFTS Av r STRUCTURAL ENGINEERING REVIEW THIS CONSTRUCTION HAS BEEN DESIGNED AS A MAIN WIND FORCE RESISTING SYSTEM, WITH CALCULATED GRAVITY AND WIND LOADS IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, 7th EDITION, 2020, CHAPTERS 16 8 20, ADM 2015, AND ASCE5EI 7-16 'MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES' TO WITHSTAND THE WIND LOADS ASSOCIATED WITH AN ULTIMATE WIND SPEED OF la" MPH, EXPOSURE'D, RISK CATEGORY I. J.L. SANDERS, P.E. HAS NO CONTROL OF THE MANUFACTURING, PERFORMANCE, OR INSTALLATION OF THIS PRODUCT. THESE GENERIC SPECIFICATIONS WERE ENGINEERED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICES BASED ON DATA PROVIDED BY THE MANUFACTURER. THIS STRUCTURAL REVIEW IS UMITED TO THE PRIMARY FRAMING AND CONNECTIONS AND IS NOT INTENDED TO COVER MECHANICAL AND ELECTRICAL COMPONENTS. THESE SPECIFICATIONS ARE BASED ON STRUCTURAL CALCULATIONS TITLED -4 POST SEA DRIVE UFT', WHICH CONTAIN ADDITIONAL DESIGN REQUIREMENTS AND CRITERIA AND ARE AVARABLE UPON REQUEST. THE BOAT LIFTS DEPICTED IN THESE SPECIFICATIONS AND RELATED CALCULATIONS WERE ENGINEERED AS MANUFACTURED PRODUCT FOR NONSITE SPECIFIC USE AND NOT INTENDED TO COVER SITE SPECIFIC CONDITIONS. - 'f J.L Sanders, P.E. 2515 Gratis Road NW M..a, GA3065B J.L SANDERS, P.E. Date: Phone: 2=71-1578 Reg. Florida No. 66361 PILE SPACING CHART The boat center of gravity needs to be set in the center of the top beam Lift Capacity '1" Dimension "2" Dimension Recommended Pile Diameters Lb. Ft. Ft. in. 5,000 11 8 7,500 10,000 12 12 12.5 10 12,000 14 000 16,000 14 20,000 14 16 24,000 16 28,000 12 STAINLESS STEEL PILING MOUNT BRACKET - RECOMMENDED ATTACHMENT BASED ON BRACKET CONFIGURATION. VERIFYADEOUACY BASED ON ACTUAL SITE CONDITIONS: 4-3/8" STAINLESS STEEL LAG SCREWS USED TO CONNECT THE BRACKETS TO THE PILING AND 2-3/8" STAINLESS STEEL CARRIAGE BOLTS USED TO CONNECT THE BRACKETS TO THE LIFT CHANNELS NOTE: THIS STRUCTURE HAS BEEN DESIGNED FOR LOADS ASSOCIATED WITH AN ULTIMATE WIND SPEED OF 180 MPH, EXPOSURE "D", RISK CATEGORY I, o 0 CALCULATED PER FLORIDA BUILDING CODE 7th EDITION, 2020, ASCE/SEI 7-16 AND ADM-2015. BOATS SHALL NOT BE STORED ON LIFTS DURING HIGH WIND EVENTS. IN GENERAL, PILING PENETRATION TO BE A MINIMUM OF 10' INTO THE SAND BOTTOM OR S INTO THE ROCKSTRATA. SUBSURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES. ALL PILINGS TO BE 2.5 C.C.A. PRESSURE TREATED WOOD. ALLSTRUCTURAL MEMBERS TO BE 6061-T6 ALUMINUM. SUMMARY OF DESIGN FEATURES O O O O 00000 O LIFT CAPACITY TOP BEAM CHANNEL 2 EACH CRADLE I -BEAM 2 EACH BUNK CABLE SIZE CABLE GUIDE WINDDIEER MOTOR INCHES P LING BOARDS (PT) SPREAD POST HGTH ERGS SHAD VOLTAGE OF PER MIN SIZES Lbs INCHES INCHES INCHES IN 5,000# 4Hx.15 2 W x .23 6Hx.19 4 W x .29 107.75 2-3/4HP 120V�20A 141" OAL 120" LGTH Mw 4 - 5k.1 6" x15' ST 1 PART w a 240V/10A 39.701 B" DIA 7,500# 5Hxx. 2.25 W x .26 6Hx.19 4Wx .29 120.75 2 1 HP 120V28A x 153" OAL 144" LGTH oa MCC o �< 240V714A 6Hx.17 8Hx.23 10,000# 2.5 W x .29 5 W x .35 2 - 3(4 HP x 153" DAL 150" LGTH '�� < T 0 120V//20A 240V(1 OA 7 H x .17 8 H x .25 12,000# 2.7 5Wx.41 ir x555y"xOAL 150" LGTH 4-5 /16" x20PARTT 116.75 o LI" Q< 19.85" 7Hx.17 8Hx.25 14,000# 2.755Vx.9 " 5Wx.41 o\ x 15 0 L 150" LGTH N ra 2-1 HP 10"DIA 8Hx.19 10Hx.25 16,000# 3 W x .35 6 W x .41 a a 12OV/28A x 153" OAL 168" LGTH c=a� �a N 240 114A 8 H x .25 10 H x .25 20,000# 3.75 W x .41 177 DAL 6Wx .41 192" LGTH o < 4- 5/16" 127.75 0 x OU S x35PARTT _ rN �' 13.20" 8Hx.25 10Hx.29� 24,000# 3.75Wx.41 6Wx.50 151.75 x 201 DAL 192" LGTH 28,000# 10Hx.526 2.88 W x .437 12Hx.31 7 W x .62 4-5/16" x60' ST ST 150.3125 2-1-12H 120V�30A 857" 12" DIA x 206 DAL 192" LGTH 4 PART 240V/15A Golden Manufacturing, Inc. 17611 Cast Street, N. Fort Myers Florida 33917 Pub 10/26/21