Loading...
HomeMy WebLinkAboutNotice Of Product CertificationRECEIVED NOTICE OF PRODUCT CERTIFICATION ?-I I Z - OG Z j FILEC®Py Company: Masonite International Corporation Certification No.: NI013747-R2 i K111i. 111.��{ �3 1955 Powis Road Certification Date: 06/08/2017 West Chicago, IL 60185 Expiration Date: 06/30/2025 Revision Date: 07/27/2020 / .� '�t�t „�. r • Product: Wood -Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites w/Wood Frame unless noted �Rien£pFta�l ( ) Specification: TAS 201/202/203-94 Impact: Large Missile Impact Rated Non -Impact Glazing: Insulating Glass (Tempered) The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at w-nv.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute(ANSI . Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & Outswing Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0" x 6'8" +70/-70 0.0 psf Yes ATLNC 1001.01-13 Single Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 X O/S Opaque 3'0" x 6'8" +70/-70 3.0 psfl Yes ATLNC 1001.01-13/W-1857 Single 4.5 psf' Maximum Panel Size: 3'0" x 6'8" 7.50 pSf3.4.5 Anchor Details-DWG-MA-FL0211-17 XX I/S Opaque 6'0" x 6'8" +55/-55 0 psf Yes NCTL-210-2930-1 Double Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 XX O/S Opaque 6'0" x 6'8" +551-55 3.0 psfl Yes NCTL-210-2930-1 Double 4.5 psf' Maximum Panel Size: 3'0" x 6'8" 7.50 psf' AnchorDetails-DWG-MA-FL0211-17 XO/OX I/S Opaque Door 6'0" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 XO/OX O/S Opaque Door 6'0" x 6'8" +551-55 3.0 psfl Door -Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite 4.5 psf' Sidelite-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50 psf' Anchor Details-DWG-MA-FL0211-17 OXO I/S Opaque Door 910" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 OXO O/S Opaque Door 910" x 6'8" +55/-55 3.0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50 psf' Anchor Details-DWG-MA-FL0211-17 OXXO I/S Opaque Door 12'4" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-171,0211-17 OXXO O/S Opaque Door 12'4" x 6'8" +551-55 3.0 psfl Door -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50 psf' Anchor Details-DWG-MA-FL0211-17 Dumper vuiswmg i nresnoid 2 -Denotes zrheries Outswing Threshold 3-Hi-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Outswing Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: 1111 MASONITC. WOOD -EDGE STEEL DOOR UNIT 6'-8" DOUBLE DOOR WITH / WITHOUT SIDELITES GENERAL N07ES 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION OR THE HIGH VELOCITY HURRICANE ZONE (HVHZ), HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE PANELS, BUT IS REQUIRED ON SIDELITES. 3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 4. PLASTICS TESTING: TGcT nccro,onnlJ ncclrAlnTn1., SELF IGNITION TEMP ASTM D1929 740 -F > 650 'F RATE 'OF BURNING ASTM D635 077 IN/MIN SMOKE DENSITY ASTM D2843 13.47 TENSILE STRENGTH- '.. ASTM D638 7A% DIFF • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 149" MAX. OVERALL FRAME W107H 21" MAX 36,375" MAX. D.L.O. PANEL WIDTH 37.5" MAX. IN/ASTRAGAL I FRAME WIDTH n � N m w �Ci x a IL DOUBLE DOOR UNIT WISIDELITES 17 Loll IN i off- IIA1021cmillit M. WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER HIGH DAM:SERIEj0 S 37.5 -70:0+ _ 070, .0. 0+550 :0 +50X . -50.0 +50.0XX -50.0 _TX 74 +-5 + jO . orXO 75 -550+ . . 50.0 -50.0 N A N OXO 2 5.0.N. 0+ .. .. .. 50-500 N11 N A5 149 + .�55 +550 . .. ... 5.00::OXXO 0 N/A N/A TABLE OF CONTENTS SHEET # DESCRIPTION -� er i KURT BALTHAZOR FLORIDA P.E. #56533 L0 J C) � O � J �O Z a ti L0 L0 O 0 cri Uat>>R h 2 o ao�`y',rQi W C, O g 0 0 r: SCaLF, N.T.S. DWG. BY: SWS CHK. BY: GNAWING NO.: DWG-MA-FLO21 1- 1; OF 3" --1 SEE DETAIL .0. 6"3 SEE DETAIL 3• "E" _ 3.. 3" 1 11�1�_ — 6" 6" Br — O 6.. Il 6" lr 3" A k #8 x 2" #8 x 2" 0 DETAIL "D" Ji v THRESHOLDINSWING 3" 3 6" SEE DETAIL .r #10 x 5/8". #10 x 5/8 #10 x 2-1/2" #10 x 1" #10 x 1" #10 x 5/8," DETAIL "C" 0.9621 T BUMPER O/S THRESHOLD I—+ 3"6" w a SEE C7 w w 0 a #8 x 2" DETAIL "E" ASTRAGAL ATTACH ASTRAGAL RETAINER BOLT STRIKE PLATE TO FRAME AS SHOWN. 1.437" I T4 O/S THRESHOLD I 1 I 1.482" _ 1.75"2;2-� 1.047" 1.437" T T T Z—SERIES O/S THRESHOLD HIGH DAM 0/S THRESHOLD HP O/S THRESHOLDTHRESHOLD ®'lip, a 'vt G` N to 6" EE DETAIL C'• 6" ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW DETAIL "E" ASTRAGAL ¢ 00 Q olcol Z J O O— �O Lu Z �Z Lc� U HOT MELT t0 ELASTOMER----., #6 X 1-1/2" PHS HOT MELT 1/2• BITE (pwm ELlSTOMER .. A"y"`:: RCe��6G�6vlt�lm-, onTE 5126 17 ".:;. EXTERIOS 1Cl1EBI0B 1Jde sr„ v N.T.S. TYPICAL GLAZING DETAIL OWO- BY: Sws NON —IMPACT GLASS CHIC. BY. DWG—MA—FLO211—I? sHEET 2 of 3 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". 3 I 6"3� I 3"6" 31 10 0 N O a W U d SEE DETAIL "D" SHT. 2 W W O: N O -It G' 10 6" 6' II G � fl IIII B 3" -A I— , 6"3-6Y � 6" MIN f 0M.25" SHIM CL TYPICAL MASONRY ANCHOR INSTALLATION 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. HARDWARE SCHEDUL W a J J Li W W O m t 10 4- 2 0 a 0 3" =$�zU� IaP t OZ¢ 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES. 1"X7/2' CORRUGATED /�10X2" WOOD SCREW 3" FROM EACH END 6" FROM EACH END AND 7" OC AND 12" OC ACRYLIC LATEX CAULK ACRYLIC LATEX CAULK CL •; : R COMBINATION WOOD COMBINATION WOOD 1.50" MULLION (BOXED) MULLION (BOXED) MIN I ` MAX" SHIM CL TYPICAL WOOD BUCK ANCHOR INSTALLATION (3W0 8 D SCREWS EACH END INTEGRAL WOOD MULLION (CHS) DATEo 5126117 SCALE. N.T.S. DWG. BY: SWS CHK. BY: DRAWING NO.: DWG-MA-FL0211-1: sHEET 3 OF 3 L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville, NC 27023 Report #: 514010B 434-688-0609 Date: 10/10/2017 rllomas(clrlomaspe, com Test Report. N/A Product: Single door Tx 6'8" (Wood Frame) Scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/ 6 w/out gap; a. With threads present in shear plane Fastener type: #10 wood screw (NDS 2018, TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Or: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb = 80,000 psi Side member: Douglas Fir -Larch (G=0.50) Main member: Spruce -Pine -Fir (G=0.42) Side member thickness: t,= 1.000 in Main member thickness: %= 1.500 in Side member dowel bearing strength: F. = 4,650 psi Main member dowel bearing strength: Fem = 3,350 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: I, = 1.140 in Mode I, Mode I, Made IT Mode III, Mode III, Mode IV qm = 636.5 Ibs/in qs = 884 Ibs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.00135 P = 725.61 Ibs P = 884 Ibs 8: 1.07 8: 0.57 8: 0.5 8: 0.000 KD = 2.400 Kt, = 2.400 C:-427.674 C:-253.623 C: -267.699 C: -93.6 Zm= 302 Ibs Z,= 368 Ibs P = 331 Ibs Ms = 46.8 in-Ibs Mm = 46.8 in-Ibs Ko = 2.400 P = 297 Ibs P = 319 Ibs P = 263 Ibs Min. Design value: Z= ISO Ibs Z= 138 Ibs KD = 2.400 KD = 2.400 KD = 2.400 Duration Factor: CD = 1.6 Z= 124 Ibs Z= 133 Ibs Z= 110 Ibs Allowable Design Value (ZCD): Z'= 175 Ibs/anchor Fastener type: 1/4 ITW Tapcon Tabulated values N.O.A.16-1222.06 Substrate: Hollow block Minimum embedment: 1.25 in Actual edge distance: 2.50 in edge distance spacing (in) 2.00 1 4.00 2.00 130 161 4.00 163 1 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z"= 155 Ibs/anchor (per interpolation when needed) Fastener type: #10 Tek screw Substrate: 18 GA, Steel Tabulated design value: Z= 1266 Ibs Safety factor: F5= 4 Allowable Design Value (ZFs): Z'= 316 Ibs/anchor Minimum anchor capacity: 155 Ibs/anchor Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations, minimum required anchors 36.38 Design pressure: 85.0 psf I_ l% 79.25 A2 II A2 /A1 1 of 3 Max. Anchor Area Load Ind. Cap. Q Load Zone z (ff) (Ibs) (in) O.C. Result (Ibs) (Ibs) AI 2.3 195 N/A N/A 155 1 2 98 1 OK AZ 7.7 656 6.00 18.00 155 1 5 131 1 OK .-••.� Nv .v\r E N 5+�.'9(p *' • 0 • ` TATRF 00 A`E`S O,RtDP �iis�ONAL1 Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville, NC 27023 Report #: 514010B 434-688-0609 Date: 10/10/2017 rIIomas(c_lrlomaspe. corn Anchor Locations: 36.38 —18.19 6.00 TYP. � 6.00 TYP. —�— t -T 6.00 18" MAX O.C. 79.25 2of3 i 6.00 x S R • `N CEIV• * s 4-TAYVOF � • �; /ONALI���`� III Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 rllomas(lrlomaspe.com Manufacturer: Masonite Report #: 514010B Date: 10/10/2017 Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 112" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. Luis R. Lomas P.E. FL No.: 62514 3 of 3 9/2/2020