Loading...
HomeMy WebLinkAboutProduct InformationAMERICAN CRAFTSMAN WINDOWS SILVER LINE WINDOWS AND DOORS GENERALNOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-12 • ASTM E1996-17 • AAMA/WDMA/CSA 101/I.S.2/A440-11 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS. IN HVHZ AREAS, ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR AHJ. S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF DURABLE SPECIES AS DEFINED IN CHAPTER 23. B. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 1 FOR GLAZING DETAILS. 70 SERIES / V1 SERIES / (2127) SINGLE- HUNG WINDOWS FILE COPY (HVHZ) (IMPACT) MAX OVERALL SIZE CONFIG. DESIGN MISSILE WIDTH HEIGHT PRESSURE IMPACT RATING 52" 73" O/X +55/-60 PSF LMI/SMI RECEIVED JAN 19 2022 St. Lucie County Permitting TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - GENERAL NOTES & GLAZING DETAIL 2 - ELEVATION & ANCHOR LAYOUTS 3 - VERTICAL SECTIONS 4 - HORIZONTAL SECTIONS S HORIZONTAL& VERTICAL SECTIONS, INSTALLATION NOTES& REINFORCEMENT DETAILS EXTERIOR STEELSPACER 1/8" OR 3/32" SETTING BLOCK 43/64" O.A. I.G. LAMINATED GLASS CONSISTING OF: 1/8" ANNEALED GLASS 7/32"STEEL SPACER 3/32" ANNEALED GLASS 0.090"SAFLEX PVBINTERLAYER BY EASTMAN CHEMICAL COMPANY 3/32" ANNEALED GLASS relf/,ri 111 rem allt ell I M I INTERIOR MIN. GLASS BITE 7/16" 1995 SEALANT TREMCO S700 SEALANT NOTE: ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH SAFETY GLAZING REQUIREMENTS OUTLINED IN CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. ;AN CRAFTSMAN WINDOM LINE WINDOWS AND D001 ONE SILVER LINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (888) 741-0354 NLj rl Uzi H o,m z3a .Z Km�Ss` Z j 7 N Z O o R 0 w Ji F- g Jw K (7v m o to n � � z w a < a REMARKS BY I DATI 7TH FBC EDITION NUS o/14/ 3n: I am approving this document 2020.10AA 01 M05 t92'00' D S A OF , �i 0DO c T 398ED-MB oieIVD.•338 DRNIAOR R 33 N POPE CE0.T.OF AMOR-MN Na 39370 FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR I HFN SCALE: NTS DWG.#: SWD050 SHEET: 11 MAX. O.A FRAME WIDTH 52" MAX. D.L.O. WIDTH 47.69" A B 3 3 MAX. D.L.O. "O" HEIGHT33.50" C 4 MAX. O.A FRAME HEIGHT 73" MAX. D.L.O. HEIGHT 33.50' ELEVATION SINGLE HUNG WINDOW MAX. FROM COO RNERS 6"MAX. O.C. 3" MAX. X FROM CORNERS T I _ 6" MAX. 6.25" MAX. O.C. FROM I� CORNERS I NOTE: ALL FASTENERS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK MUST BE FLAT HEAD 12.50" MAX. O.C. ANCHOR LAYOUT NAIL FIN - SINGLE HUNG WINDOW 6.25" MAX. FROM CORNERS L ANCHOR LAYOUT THROUGH FRAME - SINGLE HUNG WINDOW AERICAN CRAFTSMAN WINDO%A VER LINE WINDOWS AND D001 ONE SILVER LINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (888) 741-0354 N u„ Z n F VI Z `J g s CL 0 O p�6 .Z 2 L7 mm Pqi »N a zgsQ�� v�i=> w= -Z ° w VIZ �co Q m o vI W w p 133 a <� I... W f- a BY DATI REMARKS 7TH FBC EDITION JNUS 0114/ o g q of o DI1Pki�cR G` 3N E OMJUI 8F BLVD. • 333 DMA B CK FL 330M F PE MT. OF AUFHORP WN Nu 33SM FL #: FL14911 DATE: 01.23.18 DWG. BY: I CHK. BY: HR HFN SCALE: NTS DWG.#: SWD050 SHEET: 2 OF 5 - SEE GLAZING DETAIL, SHEET 1 INTERIOR _ SEE GLAZING DETAIL, SHEET 1 AQ VERTICAL SECTION 3 NAIL FIN SEE GLAZING DETAIL, SHEET 1 C! VERTICAL SECTION 3 THRU FRAME AERICAN CRAFTSMAN WINDOVI .VER LINE WINDOWS AND DOOI ONE SILVER LINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (888) 741-0354 NLj �.3 Z ( wZ o y 0 �3<< �3 G Ogg 1, \_ = 5 oaaa W W I K J W o 3 m W L7 y m O] In 0 w w w a / r a REMARKS BY I DATI 7TH FBC EDITION NUS O/14/ 01 ••N:77 c* fl S A OF ar . - E OANIA BFAOi Blw. • 338 --N, R 3M FBVE QAT. OF AUFH00.QA— No. 29578 FL #: FL14911 DATE: 01.23.18 DWG. BY: I CHK. BY: HR HFN SCALE: NTS DWG. #: SECTION FOR INTERIOR SECTION FOR BLOCK & TACKLE BALANCERS SEE GLAZING DETAIL SHEET 1 SEE GLAZING CONSTANT FORCE / o DETAIL SHEET 1 BALANCERS _ G C _ Ii— � / EXTERIOR r D.L.O. MAX. FRAME WIDTH HORIZONTAL SECTION 4 UPPER SASH SEE GLAZING SEE GLAZING DETAIL SHEET 1 INTERIOR DETAIL SHEET 1-\,, _ EXTERIOR D.L.O. MAX. FRAME WIDTH rD--\ HORIZONTAL SECTION 4 LOWER SASH AERICAN CRAFTSMAN WINDON .VER LINE WINDOWS AND DOOI ONE SILVER LINE DRIVE NORTH BRUNSWICK, N108902 PH: (888) 741-0354 N y u„ Z m �o z a n m cr _ZG z�a � crr��S3 vW,o .N z-- \ _ = Z s z<o $ . W W > N x W ¢ _ m m cc } o In � w H p w a a W BY DATI REMARKS 7TH FBC EDITION NUS o/14/ —.6SfIECONDNIDNSG EINSf<IUTONMOEVIK FROM tN E RE4UI REMENR OETN—EREIN. A OCEH9D ENGINE ER 0 R ARdDFR SMALL vRE VARE vEE svEaf Ic E S Ali �* N .77 o S A OF :lo 0� _ O a 390 E DANIA BFACII BIYD. 330 DANIA BEACH, EL 33003 BBPE CEAT.OE A.0R1U— Nn 29090 FL #: FL14911 DATE: 01.23.18 DWG. BY: I CHK. BY: HR HFN SCALE: NTS DWG.#: SWD050 SHEET: MIN. SUBSTRATE EDGE DISTANCE BY OTHERS MIN. EMBEDMENT PERIMET SEALANT BYOTHERS SEANT o SHIMS ACE EXTERIOR 19 INTERIOR VERTICAL SECTION 5 THROUGH FRAME (HEAD) 1/4" MAX. SUBSTRAT SHIM SPACE BY OTHERS INTERIOR z z w ao EXTERIOR z EXTERIOR 1/4" MAX. SHIM SPACE INTERIOR PERIMETER SEALANT BY OTHERS EXTERIOR BY OTHERS SCREW IN THE INTERIOR CHANNEL MIN. EDGE DISTANCE SCREW IN THE EXTERIOR CHANNEL MIN. EMBEDMENT rff-� HORIZONTAL SECTION 5 THROUGH FRAME (JAMB) MIN. EMBEDMENT SUBSTRATE ---] �- /BY OTHERS w w L9 u oZ w Q Z F~i1 io14!iS,IHIMSPACE "/4" MAX. EXTERIOR OR HORIZONTAL SECTION 5 NAIL FIN (HEAD) REINFORCEMENT DETAILS 0.83" -1 [-1 INTERIOR0.77 0.9 0.45" 0.06" 0JLOCK RAIL TOP O LOCK MEETING RAIL O ALUMINUM ALUMINUM MIN. EDGE ID STANCE THORIZONTAL SECTION �E� VERTICAL SECTION NAIL FIN (JAMB) 5 MEETING STILE INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OF 31/21NCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/81NCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. S. FOR MASONRY OR CONCRETE OPENINGS, 1X WOOD BUCK MAY BE USED (OPTIONAL AS LONG AS THE MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOST SUBSTRATE. SEE GENERAL NOTE N3 ON SHEET 1 FOR MORE INFORMATION. 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. B. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK, USE FLAT HEAD ANCHORS. [- 0.34" 0.13" Y-- 0.46" 0.87" /IERICAN CRAFTSMAN WINDO%A VER LINE WINDOWS AND DOOI ONE SILVER LINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (888) 741-0354 iz i N 3 O lJ m z ^ �O ZE "tea o "£ �3a szl- p33;g vwi L92 WZw LEI 'I j7nl ��w �xx Dagu zggas D:3 p'cd�6 a (z z 3 V�wl Z NZK In m m ov 0 _ w a a � a REMARKS BY DATI 7TH FBC EDITION NUS o/14/ BOTTOM LIFT RAIL & SASH 1HEV AW ON OE NL OF WeFDNFAE NARFGN ALUMINUMro m ONS qua o� ooE RFOUiRErafx73D uIEDNEREIN,ArICEfEFI ENGINEERORARdITECrS PREPARESOESPEOFK OOCEIMEMBFORUSEWRHTH ...E- %IIIhLJ.TJ,,,,/ ANCHORSCHEDULE METHOD SUBSTRATE ANCHORSCHEDULE MIN EMBEDMENT MIN.EDGE DISTANCE WOOD: MIN. SG=0.55 #8 WOOD SCREW 1.5' 0.75' FANHEAD NAILING FIN METAL: 18 GAUGE Sleel, /!8 TEK SCREW 3 THREADS MIN MIN. Fy = 33K51 PENETRATION BEYOND 0.50' METAL #10 PAN HEAD IN EXTERIOR CHANNEL 1.5' 0.75' WOOD: MIN. SG = 0.11 1110 FLAT HEAD IN THE INTERIORCHANNEL 1 5' 0.75' 410 PAN HEAD IN 3 THREADS MIN EXTERIOR CHANNEL PENETRATION BEYOND 0.50, METAL 18 GAUGE Sleel, METAL THROUGH FRAME MIN. Fy = 33KSI NFLATHEADINTHE 3 THREADS MIN IN INTERIOR CHANNEL PENETRATION BEYOND 0.50' METAL CONCRETE rc3000PS1 3/16' IIW TAPCON 125' FLATHEAD MASONRY: CMU per ASTM 3/16'11W TAPCON C90 MIN. 2000 PSI FLAT HEAD 1.25' N :7 7 S A OF i �!/1!j 0.K,�(� O IDP: WW���qnn E 398 E. DANIA BEACH BFVD. 1338 DANIA...R R 330M FBPE CERL OF AOMORRATION No. 89S78 FL#: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR HFN SCALE: NTS DWG.p: swnnsn /(2rBUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 MI .�A • ,e., 1 of American Craftsman Windows 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Silver Line Windows and Doors 70 Series / V1 Series / (2127) Single -Hung Windows (HVHZ)(IMPACT) for Florida Product Approval Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub — Category: Single Hung Product: 70 Series / V1 Series / (2127) Single -Hung Windows Material: PVC Product Dimensions: See Installation Instructions, SWD050 Prepared for: Silver Line Windows and Doors One Sliverline Dr. North Brunswick, NJ 08902 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:10/14/2020 Contents: Evaluation Report Pages 1-4 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2020.10.22 02:28:29 +02'00' N.77 0� -o S A OF 0 °�eeelllt111�`,, Hermes F. Norero, P.E. Florida P.E. No. 73778 BUILDING DROPS A Perfect Solution in Every ,Drop! Certificate of Authorization: 29578 Manufacturer: Silver Line Windows and Doors Product Category: Windows Product Sub -Category: Single Hung FL#:FL14911 Date: 10/14/20 Report No: 7263 Compliance Method: State Product Approval Method (1)(d) Product Name: 70 Series / V1 Series / (2127) Single -Hung Windows (HVHZ) (IMPACT) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Windows and Doors based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD050, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of Installation Instructions SWD050 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWD050 for size and design pressure limitations. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 2 of 4 BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Drop! Date: 10/14/20 Certificate of Authorization: 29578 Report No: 7263 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Quality Assurance Entity through Window and Door Manufacturers Association (FBC Organization #QUA2515). Performance Standards: The product described herein has been evaluated per: Referenced Data: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-12 • ASTM E1996-17 • AAMA/WDMA/CSA 101/I.S.2/A440-11 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization # TST1589) Report: Dated: NCTL110-16327-1 08/13/2013 Signed and Sealed by: Harold E. Rupp, FL PE No 15935, Sealed Date 02/06/18 NCTL 110-16327-2 11/05/2013 NCTL110-16327-3 08/13/2013 11524.01-109-47 05/01/2018 11238.01-109-47 03/28/2022 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization #: QUA2515) 3. Material Certification Miami -Dade County Notice of Acceptance Eastman Chemical Company (Previously Solutia) Saflex (Vanceva Composites) PVB Interlayer 4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 3 of 4 Installation: BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 FL#:FL14911 Date: 10/14/20 Report No: 7263 Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Equivalence of Test Standards: Various test standards have been evaluated for differences in test methodology, if any, between tested editions of the test standards listed below and those editions referenced in the current Florida Building Code. Manufacturer has tested their products to the following test standard edition(s): 1) AAMA/WDMA/CSA 101/I.S.2/A440-08 2) ASTM E1886-05 3) ASTM E1996-06/09/12 Chapter 35 of the current Florida Building Code references the following editions of the above mentioned test standards: 1) AAMA/WDMA/CSA 101/I.S.2/A440-11 2) ASTM E1886-12 3) ASTM E1996-17 After review of the above mentioned referenced standards and editions, it has been found that no significant technical changes have been made to the test standards that would affect the results. All referenced standards have been found to be equivalent. All material test results meet minimum requirements of the current FBC including HVHZ provisions. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 4 of 4