Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2012-0722 ProdRevAff&EvalRepts
Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit# 2012mO722 Owners Name Mark Walpert Applicant: Mark Walpert Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures Design Pressure Number Type Windows +47.1 -57.5 +80 -80 Comfort Line 2100 Awning 15974.2 R3 Impact Direct to frame per instr 15974.2 Mullions see attached window table for details Fixed Glass +43.8 -47.8 +80 -80 Comfort Line 2100 Picture 15973.3 R4 Impact Direct frame per instr 15973.3 Block Glass Skylights Sliding Glass Doors +43.4 -47.4 +50 -50 Comfort Line 5000 Futura 16112.1,.2 R2 Impact Direct to frame per instr 16112.1,.2 Swing Type Doors +45.4 -49.4 +50 -50 Jeld-Wen Smooth Pro 16674.1,2,3,4 R16 Impact Direct to frame per instr D015694,5,6,7.2 French Doors see attached door table for details Garage Doors +38.5 -42.2 +60 -60 Alpine Over. Redi-Storm 14017.1 R1 approved in permit 1506-0284 1/5/16 Hurricane Protection +40.0 -48.9 +54 -54 STO EIFS StoTherm CI 20110.1 R3 XPS adhered to sub, reinforced finish per S118G Roof Ventilation FLAT+19.1 -87.0 -502.5 Sika Corp Sikalastic RoofPro 17440.1 R4 C-4 polyurethane RoofPro TC System inst 14001.4 Roofing Material PITCH+19.1 -87.0 -127.5 GAF Everguard TPO 5293.1 R46 S-256,278,or307 adhered to deck board over 2"xps Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Mark Walpert Mark Walpert Date: l021.0dbyMa9:11 -0rk e0 rt Name: Signature: Date:2021.07.10 16:29:11 -04'00' seal Design Prof: see attached reports Cert.No. Date: 7/8/2 WINDOW TABLE Walpert Res. 5050 N A I A Hutchinson Is FL 06/09/21 KEY Loc'n - CL 2100 Awning Rough Hgt Pressure Area Press FL Direction Frame w"x h" Open " FIr" Req psi -sqft Rtg psi Ap G2 Hex-NW 31 1/4 x 39 1/2 31 3/4 x 40 44 +47.1 -51.1 8.82 +80 -80 15974.2 G3 CWStor-W 54 3/4 x 39 1/2 55 1/4 x 40 48 +46.1 -50.0 13.35 +80 -80 G6 Util-W 39 x 39 1/2 39 1/2 x 40 44 +47.1 -51.1 10.97 +80 -80 G7 GarE-S 27 1/8 x 39 1/2 27 5/8 x 40 62 +47.1 -51.1 7.67 +80 -80 G8 GarW-S 27 1/8 x 39 1/2 27 5/8 x 40 62 +47.1 -51.1 7.67 +80 -80 G11 Gar-N 27 1/8 x 39 1/2 27 5/8 x 40 61 +47.1 -51.1 7.67 +80 -80 G14 NStor-N 52 1/2 x 39 1/2 53 x 40 44 +47.1 -51.1 14.72 +80 -80 G17 NStor-E 59 1/2 x 39 1/2 60 x 40 44 +45.0 -49.0 16.67 +80 -80 G19 NStor-E 59 1/2 x 39 1/2 60 x 40 44 +45.0 -49.0 16.67 +80 -80 G23 SEStor-E 23 1/2 x 39 1/2 24 x 40 44 +42.1 -51.1 6.67 +80 -80 G25 Equip -S 59 1/2 x 31 1/2 60 x 32 52 +46.2 -50.2 13.33 +80 -80 G26 SEStor-S 59 1/2 x 31 1/2 60 x 32 52 +46.2 -50.2 13.33 +80 -80 G27 SEStor-S 51 1/2 x 31 1/2 52 x 32 52 +46.7 -50.7 11.55 +80 -80 F1 MBt-S 35 1/2 x 39 1/2 36 x 40 40 +47.1 -51.1 10 +80 -80 F2 MBt-N 35 1/2 x 39 1/2 36 x 40 40 +47.1 -51.1 10 +80 -80 F3 Stdy-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F4 Lndg-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F5 DR-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F6 Bt2-S 31 1/2 x 39 1/2 32 x 40 40 +47.1 -51.1 8.89 +80 -80 F7 Br2-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F15 K-E 59 1/2 x 39 1/2 60 x 40 44 +44.5 -48.5 16.67 +80 -80 F23 MBr-S 39 1/2 x 39 1/2 40 x 40 40 +47.1 -63.1 11.11 +80 -80 F24 MBr-S 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 LI L-W 59 1/2 x 39 1/2 60 x 40 40 +44.3 -57.5 16.67 +80 -80 L2 L-N 59 1/2 x 39 1/2 60 x 40 40 +45.0 -49.0 16.67 +80 -80 U-.27 (R-3.7), CR-57, SHGC-.18, LSG-2.11,Vis Light Trans-38%,Air Infiltration-0.007scfm/ft2@1.57psf KEY Loc'n - CL 2100 Fixed Rough Hgt Pressure Area Press FL Direction Frame w"x V Open " FIr" Req psi -sqft Rtg psi Ap F17a W LR- E 71 1/2 x 71 1/2 72 x 72 120 +43.8 -47.8 36 +80 -80 15973.3 U-.25 (R-4.0), CR-58, SHGC-.18, LSG-2.11,Vis Light Trans-38%,Air Infiltration-0.005scfin/ft2@6.24psf White frames and accessories Impact requirement Large Missile level D for Zone 3 "Turtle Glass" required: Cardinal LoE3-340 laminated impact insulating Stainless steel hardware where available. DOOR TABLE Walpert Res. 5050 N Al Hutchinson Is FL 06/23/21 Comfort Line 5000 FG SGD, Impact KEY Dir Configurat Frame w x h" Opening Hgt Flr" Area Pressure Press FL Room ion w"x h" /Step" -sqft Req psf Rtg psf Appry F8-N Br2 2P2T OX 59 1/2 x 79 1/2 60 x 80 -1.5/4 32.85 +43.4 -47.4 +50 -50 16112.1 F9-N Br3 2P2T OX 71 1/2 x 79 1/2 72 x 80 -1.5/4 39.47 +42.9 -46.9 +50 -50 16112.1 F11-N FR 2P2T OX 71 1/2 x 79 1/2 72 x 80 -1.5/4 39.47 +42.9 -46.9 +50 -50 16112.1 F12-E FR 3P2T OXO 110 x 95 1/2 110 1/2 x 96 -1.5/4 73.21 +41.4 -45.4 +50 -50 16112.2 F14-SE K 2P2T OX 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3 -46.3 +50 -50 16112.1 F16-NE LR 2P2T XO 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3 -46.3 +50 -50 16112.1 F18-SE LR 2P2T OX 59 1/2 x 95 1/2 60 x 96 -1.5/4 39.46 +42.9 -46.9 +50 -50 16112.1 F21-E MBr 2P2T OX 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3 -46.3 +50 -50 16112.1 L3-E Loft 2P2T OX 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3 -46.3 +50 -50 16112.1 U-30 (R-3.3), CR-58, SHGC-.18, LSG-2.11,Vis Light Trans-38%,Air Infiltration-0.126scfm/ft2@1.57psf Smooth-Pro FG with Co m osite Frame, LMI & SMI Im act KEY Configuration Frame Opening Hgt" Area P Req P Rtg FL Notes Loc'n w"x h" w"x h" Stp" -sgft psf psf Appry G4-W XX Inswing 74 x 74.5 x 0 50.33 +42.3 +50 16674.3 Water Infil NA Entry LH Active 97 15/16 98 3/8 -4 -46.3 -50 excl infil accept G10-N X Inswing 37 1/2 x 38-x -1 25.5 +44.4 +50 16674.1 Water Infil NA Garage RH 97 15/16 98 3/8 -7 -48.4 -50 excI infil accept G13-W X Inswing 37 1/2 x 38-x 0 25.5 +44.4 +50 16674.1 Water Infil NA N Entry LH 97 15/16 98 3/8 -3 -48.4 -50 excl infil accept G18-SE XX Inswing 74 x 74 1/2 x 0 42.11 +43.6 +50 16674.3 Water Infil NA N Store RH Active 81 15/16 82 3/8 -2 -47.6 -50 exc2; OH ratio>1 G21-E X Inswing 37 1/2 x 38 x 0 21.33 +44.9 +50 16674.1 Water Infil NA R Entry LH 81 15/16 82 3/8 -2 -48.9 -50 exc2; OH ratio>1 G24-E X Inswing 37 1/2 x 38 x 0 21.33 +44.9 +50 16674.1 Water Infil NA Equip RH 81 15/16 82 3/8 -2 -48.9 -50 exc2; OH ratio>1 F10-N X Outswing 37 1/2 x 38 x -1.5 21.13 +45.0 +50 16674.2 LowE3340 Bath3 RH 81 1/8 81 5/8 -4 -49.0 -50 Water Infil 9psf F17-E XX Outswing 74 x 74 1/2 x -1.5 49.91 +42.3 +50 16674.4 LowE3340 LR LH Active 97 1/8 97 5/8 -4 -46.3 -50 Water Infil 9psf F19-E X Outswing 37 1/2 x 38 x -1.5 21.13 +45.4 +50 16674.1 Water Infil 9psf E Bath LH 81 1/8 81 5/8 -4 -49.4 -50 M2-E X Inswing 37 1/2 x 38 x -1.5 21.13 +45.0 +50 16674.2 LowE3340 Mez Dk LH 81 1/8 81 5/8 -4 -49.0 -50 exc2; OH ratio>1 U-.29 (R-3.4), SHGC-.18,Vis Light Trans-38%,Air Infiltration-<0.3scfm/ft2 NFRC400 (overhang>height) Impact requirement Large Missile level D for Zone 3 "Turtle Glass" required: Cardinal LoE3-340 laminated impact insulating R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report Report No.: FL-15974.2 Date: Augtist3l,20-17 Product Sub Category Manufacturer Product Name Category Comfort Line Inc. 2100 Series Windows Awning 5500 Enterprise Blvd. Fiberglass Awning Window Toledo,OH 43612 'Impact' (419)729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F. Schmidt, P.E.(System ID# 1998)for Comfort Line Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15974.2 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15974.2 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02850544 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright TEL 02850545 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright TEL 02850546 ASTM E1886-05/E1996-06 Testing Evaluation Lab.,lnc. V.K.Wright 2. Miami Dade NOA Materials Testing 14-0916.11 SentryGlas Interlayer(Kuraray America, Inc.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-15974.2 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. 5. Quality AssuranceCH Certificate Certificate of Participation issued by National Accreditation and ���%�� �,•�••" .�T��i i Management Institute, certifying that Comfort Line Inc. is :'�,�OEMSF•°% manufacturing products within a quality assurance program that No 43409 complies with ISO/IEC 17020 and Guide 53. . * G STATE OF :JU 4 Q 4/: Lyndon F.Schmidt,P.E. ��Q ` ,� FL PE No.43409 �i�S' •'••.••••••' ��, 8/31/2017 Sheet 1 of 1 ���j�/0NV,;11- R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report Report No.: FL-15973.3 Date: Augast31,2017 Product Category Sub Category Manufacturer Product Name Comfort Line Inc. 2100 Series Windows Fixed 5500 Enterprise Blvd. Fiberglass Picture Window Toledo,OH 43612 "Impact' (419)729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E.(System ID# 1998)for Comfort Line Inc. based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"Y and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15973.3 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15973.3 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02850547 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright TEL 02850548 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright TEL 02850549 ASTM E1886-05JE1996-06 Testing Evaluation Lab.,lnc. V.K.Wright 2. Miami Dade NOA Materials Testing 14-0916.11 SentryGlas Interlayer(Kuraray America, Inc.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-15973.3 RW Building Consultants, Inc. (CA#9813) r Lyndon F.Schmidt, P.E. un�,, a, 4. Calculations Prepared by e®�G,CDC-1 �,V";,'J°e.� Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) �.,e° \.�.•y •1'J.c�,�' Lyndon F.Schmidt, P.E. 5. Quality Assurance 434On ZrCertificate of Participation issued by National Accreditation and _ Management Institute, certifying that Comfort Line Inc. is .manufacturing products within a quality assurance program that ° � .�"'--� . [f5 complies with ISO/IEC 17020 and Guide 53. STATE OF°, ��o�'��°•�•� Z`� ®��� Lyndon F.Schmidt,P.E. ° a FL PE No.43409 "A������ 8/31/2017 Sheet 1 of 1 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report Report tAugast3l,2017 Product Category Sub Category Manufacturer Product Name Comfort Line Inc. Series Futura Exterior Sliding Exterior 5500 Enterprise Blvd. Fiberglass Sliding Glass Door Doors Door Assemblies Toledo,OH 43612 'Impact' (419)729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F. Schmidt, P.E.(System ID# 1998)for Comfort Line Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone'(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering. This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2.12.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-16112.1 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-16112.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02850551 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright TEL 02850552 ASTM E1886-05/E 1996-06 Testing Evaluation Lab.,lnc. V.K.Wright 2. Miami Dade NOA Materials Testing 14-0916.11 SentryGlas Interlayer(Kuraray America, Inc.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-16112.1 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) ,���I�Illt►tttt Lyndon F.Schmidt, P.E. 01 SCH�� 5. Quality Assurance �� F;•..•••..• Certificate of Participation issued by National Accreditation and j v:��,\Q E N Stc'•. i��p Management Institute, certifying that Comfort Line Inc. is No 43409 manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. 9: STATE OF p :� T o '' Fs4 R,®�C?`��� Lyndon F.Schmidt,P.E. So®j1�Ae;' FL PE o. 3409 Sheet 1 of 1 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product / Report Report N/ i Date: August3l,2017 Product Category Sub Category Manufacturer Product Name Comfort Line Inc. Series Futura Exterior Sliding Exterior 5500 Enterprise Blvd. Fiberglass Sliding Glass Door Doors Door Assemblies Toledo,OH 43612 'Impact' (419)729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID# 1998)for Comfort Line Inc. based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-16112.2 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-16112.2 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02850551 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright TEL 02850552 ASTM E1886-05/E 1996-06 Testing Evaluation Lab.,lnc. V.K.Wright 2. Miami Dade NOA Materials Testing 14-0916.11 SentryGlas Interlayer(Kuraray America, Inc.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-16112.2 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) ����e1SCk �sij�i Lyndon F. Schmidt, P.E. 5. Quality Assurance ���, �'oG E N '�Tio Certificate of Participation issued by National Accreditation and Management Institute, certifying that Comfort Line Inc. is No 43409 o manufacturing products within a quality assurance program that o complies with ISO/IEC 17020 and Guide 53. STATE OFF /ONA`��e� LyndonFL PE No.43409 8131/2017 Sheet 1 of 1 398 E. Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 :,.. Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro / Studio Opaque (Impact) for Florida Product Approval Report No. 6264.2 Current Florida Building Code Method: 1 —A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/Smooth Pro/Studio Material: Fiberglass Product Dimensions: T-0" W x 6'-8" H (Nominal) T-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 `��{11111ff1��f O Prepared by: .`� .••'` �'• Hermes F. Norero, P.E. N . 7 7 Florida Professional Engineer#73778 7k Date: 09/13/2019 'D S A OF tY Contents: Evaluation Report Pages 1—3 S Digitally signed by Hermes F Norero Reason: I am approving this document Her mesrflN006, P.E. Date:2019.10.01 20:48:00-04'00' Florida No. 73778 ^r^) BUILDING DROPS Date: 09/16/2019 A Perfect Solution in Every Drop! Report No: 6264.2 Certificate of Authorization:29578 Manufacturer: JELD-WEN, inc. Product Category: Exterior Door Product Sub-Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(a) Product Name: Design Pro/Smooth Pro/Studio Opaque (Impact). 3'-0"X 6'-8" (Nominal) 3'-0"X 8'-0" (Nominal) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN,inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 ^r^) BUILDING DROPS Date: 09/16/2019 A Perfect Solution in Every Drop! Report No: 6264.2 Certificate of Authorization:29578 Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: CER1773) Performance Standards: The product described herein has been tested per: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization# TST1589) Report# Report Date: NCTL-210-3918-01 10/04/13 NCTL-210-3924-02 12/18/13 SJW2013-231 12/03/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 SJ W 2014-032 04/22/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-068 07/07/14 SJ W 2014-071 07/07/14 SJ W 2014-069 07/07/14 SJ W 2014-079 07/07/14 NCTL-310-19-038 07/07/14 2. Quality Assurance Entity National Accreditation& Management Institute (FBC Organization#QUA1789) Installation: Refer to Installation Instructions(D015694)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing(13015694)for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 398 E. Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 :,.. Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro Glazed (Impact) for Florida Product Approval Report No. 6265.2 Current Florida Building Code Method: 1 —A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/Smooth Pro Material: Fiberglass Product Dimensions: T-0" W x 6'-8" H (Nominal) T-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 `��{11111ff1��f O Prepared by: .`� .••'` �'• Hermes F. Norero, P.E. N . 7 7 Florida Professional Engineer#73778 7k Date: 09/13/2019 'D S A OF tY Contents: Evaluation Report Pages 1—3 S Digitally signed by Hermes F Norero Reason: I am approving this document HermesrflNofiAPa, P.E. Date:2019.10.01 20:48:41-04'00' Florida No. 73778 ^r^) BUILDING DROPS Date: 09/13/2019 A Perfect Solution in Every Drop! Report No: 6265.2 Certificate of Authorization:29578 Manufacturer: JELD-WEN, inc. Product Category: Exterior Door Product Sub-Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(a) Product Name: Design Pro/Smooth Pro Glazed (Impact). 3'-0"X 6'-8" (Nominal) 3'-0"X 8'-0" (Nominal) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN,inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: CER1773) Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 ^r^) BUILDING DROPS Date: 09/13/2019 A Perfect Solution in Every Drop! Report No: 6265.2 Certificate of Authorization:29578 Performance Standards: The product described herein has been tested per: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization# TST1589) Report# Report Date: SJW2013-196 09/03/13 SJW2013-129 08/09/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-070 07/07/14 SJ W 2014-075 07/07/14 2. Product Testing performed by Quality Testing Inc. (FBC Organization#TST7638) Report# Report Date: SJ W 2010-003 01/11/10 3. Quality Assurance Entity National Accreditation& Management Institute (FBC Organization#QUA1789) Installation: Refer to Installation Instructions (D015695)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing(13015695)for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 398 E. Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 :,.. Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro Opaque (Impact) for Florida Product Approval Report No. 6266.2 Current Florida Building Code Method: 1 —A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/Smooth Pro Material: Fiberglass Product Dimensions: 6'-0" W x 6'-8" H (Nominal) 6'-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 `��{11111ff1��f O Prepared by: .`� .••'` �'• Hermes F. Norero, P.E. N . 7 7 Florida Professional Engineer#73778 7k Date: 09/13/2019 'D S A OF tY Contents: Evaluation Report Pages 1—3 S Digitally signed by Hermes F Norero Reason: I am approving this document HermesrflNofiAPa, P.E. Date:2019.10.01 20:49:36-04'00' Florida No. 73778 ^r^) BUILDING DROPS Date: 09/13/2019 A Perfect Solution in Every Drop! Report No: 6266.2 Certificate of Authorization:29578 Manufacturer: JELD-WEN, inc. Product Category: Exterior Door Product Sub-Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(a) Product Name: Design Pro/Smooth Pro Opaque (Impact). 6'-0"X 6'-8" (Nominal) 6'-0"X 8'-0" (Nominal) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN,inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: CER1773) Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 ^r^) BUILDING DROPS Date: 09/13/2019 A Perfect Solution in Every Drop! Report No: 6266.2 Certificate of Authorization:29578 Performance Standards: The product described herein has been tested per: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization# TST1589) Report# Report Date: SJW2013-196 09/03/13 SJW2013-129 08/09/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-070 07/07/14 SJ W 2014-075 07/07/14 2. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization#QUA1789) Installation: Refer to Installation Instructions (D015696)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing(13015696)for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 398 E. Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 :,.. Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro Glazed (Impact) for Florida Product Approval Report No. 6267.2 Current Florida Building Code Method: 1 —A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/Smooth Pro Material: Fiberglass Product Dimensions: 6'-0" W x 6'-8" H (Nominal) 6'-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 `��{11111ff1��f O Prepared by: .`� .••'` �'• Hermes F. Norero, P.E. N . 7 7 Florida Professional Engineer#73778 7k Date: 09/13/2019 'D S A OF tY Contents: Evaluation Report Pages 1—3 S Digitally signed by Hermes F Norero Reason: I am approving this document HermesrflNofiAPa, P.E. Date:2019.10.01 20:50:16-04'00' Florida No. 73778 ^r^) BUILDING DROPS Date: 09/13/2019 A Perfect Solution in Every Drop! Report No: 6267.2 Certificate of Authorization:29578 Manufacturer: JELD-WEN, inc. Product Category: Exterior Door Product Sub-Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(a) Product Name: Design Pro/Smooth Pro Glazed (Impact). 6'-0"X 6'-8" (Nominal) 6'-0"X 8'-0" (Nominal) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN,inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: CER1773) Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 ^r^) BUILDING DROPS Date: 09/13/2019 A Perfect Solution in Every Drop! Report No: 6267.2 Certificate of Authorization:29578 Performance Standards: The product described herein has been tested per: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization# TST1589) Report# Report Date: NCTL-210-3918-01 10/04/13 NCTL-210-3924-02 12/18/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 SJ W 2014-032 04/22/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-069 07/07/14 SJ W 2014-079 07/07/14 NCTL-310-19-038 03/29/19 2. Quality Assurance Entity National Accreditation& Management Institute (FBC Organization#QUA1789) Installation: Refer to Installation Instructions (D015697)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing(13015697)for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 ESICC ICC-ES Evaluation Report ESR-1748 Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION 2.0 USES Section: 07 24 00—Exterior Insulation and Finish StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact Systems ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° Section: 07 24 19—Water-Drainage Exterior Insulation systems are exterior insulation and finish systems (EIFS) and Finish System complying with 2018 IBC Section 1407 and 2015 and 2012 IBC Section 1408 and IRC Section R703.9. The systems REPORT HOLDER: comply with the requirements of 2018 IBC Section 1407.4.1 and 2015 and 2012 IBC Section 1408.4.1 and IRC Section STO CORP. R703.9 as EIFS with drainage. ADDITIONAL LISTEE: StoTherm°ci°StoPanelTM Classic ci°,StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° KAPTURE PREFAB systems may be installed in buildings of any construction type under the IBC(Types I through V)and dwellings under EVALUATION SUBJECT: the IRC when installed in accordance with the applicable sections of Section 4.0. STOTHERM° ci°, STOPANELTM CLASSIC ci°, 3.0 DESCRIPTION STOPANELTM IMPACT ci°, STOPANELTM XPS AND STOPANELT CLASSIC NEXT ci° 3.1 System Components: StoTherm° ci° StoPanelTM Classic ci° Classic, StoPanelTM 1.0 EVALUATION SCOPE Impact ci°, StoPanelTM XPS and StoPanelT"" Classic NEXT Compliance with the following codes: ci° systems consist of a water-resistive barrier, adhesively applied flat insulation board, reinforcing mesh, base coat, ■ 2018, 2015 and 2012 International Building Code°(IBC) and finish coat. See Table 1 for system components. ■ 2018, 2015 and 2012 International Residential Code° 3.2 Insulation Board: (IRC) The insulation boards must be one of the following: For evaluation for compliance with codes adopted by Los a. Expanded polystyrene (EPS) complying with ASTM Angeles Department of Building and Safety (LADBS), see C578,Type I,and ASTM E2430,produced by a molder ESR-1748 LABC and LARC Supplement. with a current ICC-ES evaluation report. Properties evaluated: b. EPS insulation board produced by a molder who PROPERTY IBC IRC participates in an approved third-parry quality- Chapter Chapter assurance program. EPS must comply with ASTM Exterior insulation and finish C578, Type I, and ASTM E2430. systems (EIFS) 14 R7 c. Sto Insulation Board, EPS complying with ASTM C578, Fire-resistance-rated construction 7 R3 Type I, and ASTM E2430. Weather resistance 14 R7 d. Owens Corning Foamular°CI-C Extruded Polystyrene Special inspections,Types I-IV Type X(for use with the StoTherm°ci°XPS system as (noncombustible)construction 17 NA noted in Table 1). Structural—transverse wind load e. Dow Styrofoam Panel Core Type X recognized in resistance 16 R6 ESR-2142(for use with the StoTherm°ci°XPS system Types I-IV(noncombustible) noted in Table 1). construction 26 NA f. BASF Neopor° Rigid Foam Insulation Board (Grade F5300 Plus) (for use with StoTherm° ci° Classic, Surface burning characteristics 26 R3 StoTherm° ci° Premier, StoTherm° ci° Essence, and Ignition resistance 26 NA StoTherm°ci°Lotusan systems as noted in Table 1). ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i to any finding or other matter in this report,or as to any product covered by the report. mum Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 9 ESR-1748 I Most Widely Accepted and Trusted Page 2 of 9 EPS insulation boards must have a flame spread 4.1.4 StoPanelTM XPS: StoPanelTM XPS system is a index of 25 or less and a smoke-developed index of prefabricated application by Kapture Prefab of the 450 or less when tested in accordance with ASTM E84 StoTherm°XPS system. Sto materials, as listed in Table 6, or UL 723. must be installed in accordance with the specifications and 3.3 Substrates: installation instructions in Section 4.1.1. StoPanelTM XPS system must be fabricated in accordance with project Substrates must be one of the following: specification and StoPanelTM fabricator shop drawings for a. Gypsum sheathing board complying with ASTM C1396 each project. or ASTM C1177. When used as part of a • StoPanelTM XPS fire-resistance-rated assembly, the gypsum board must be Type X with a minimum thickness of 5/8 inch • Specification (15.9 mm). 4.1.5 StoPanelTM Classic NEXT ci°: StoPanelTM Classic b. Concrete masonry complying with the code. NEXT ci°system is a prefabricated application by Kapture Prefab of the StoTherm°ci°system which also incorporates c. Concrete complying with the code. the Sto Wedge drainage detail. Sto materials, as listed in d. Exterior plaster complying with the code. Table 6, must be installed in accordance with the specifications and installation instructions in Section 4.1.1. e. Exterior or Exposure 1 wood structural panels StoPanelTM Classic NEXT ci°system must be fabricated in complying with DOC PS-1 or PS-2. accordance with project specification and StoPanelTM 3.4 Sealants: fabricator shop drawings for each project. Sealants must comply with ASTM C920, Type S or M, • StoPanelTM Classic NEXT ci° minimum Grade NS, minimum Class 25 and Use O. • Specification 4.0 DESIGN AND INSTALLATION 4.2 Drainage: 4.1 General: StoTherm°ci° ,StoPanelTM ci°Classic, StoPanelTM Impact 4.1.1 StoTherm°ci°: StoTherm°ci°must be installed in ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° accordance with the manufacturer's installation instructions, provides drainage through the application of vertical ribbons specifications and details, which are available at of adhesive over the water-resistive barrier coating system www.stocorp.com: identified in Table 1. • http://www.stocorp.com/continuous-insulation-systems/ Additional installation and compliance information for the Sto Gold Coat water-resistive barrier system is provided in • http://www.stocorp.com/sto systems/stothermci-xps- ESR-1233 and at www.stocorp.com. lotusan/ 4.3 Wind Design: • http://www.stocorp.com/sto systems/stothermci-classic/ Table 3 presents specific StoTherm° ci° assemblies for • http://www.stocorp.com/sto systems/stothermci-lotusan/ which test data has been submitted. Other StoTherm° ci° • http://www.stocorp.com/sto systems/stothermci-xps- assemblies may be considered for approval by local essence/ officials, based on testing and/or calculations provided by a qualified design professional. • http://www.stocorp.com/sto systems/stothermci-xps- 4.4 Weather Protection: classic/ StoTherm°ci° ,StoPanelTM Classic ci°, StoPanelTM Impact • http://www.stocorp.com/sto systems/stothermci- ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° essence/ systems comply with 2018 IBC Section 1402.2 and 2015 4.1.2 StoPanelTM Classic ci°: StoPanelTM Classic ci° and 2012 IBC Section 1403.2 and IRC Section R703.1.1. system is a prefabricated application by Kapture Prefab of 4.5 Use in TypesI through IV (Noncombustible) the StoTherm°ci°Classic system. Sto materials, as listed Construction: g in Table 6, must be installed in accordance with the specifications and installation instructions in Section 4.1.1. Table 4 describes the assemblies qualified for use in Types StoPanelTM Classic ci° system must be fabricated in I through IV construction (IBC). accordance with project specification and StoPanelTM 4.6 Fire-resistance-rated Construction: fabricator shop drawings for each project. • StoPaneITM Classic ci° Table 5 describes the assemblies qualified for use in nonload-bearing fire-resistance-rated construction. • Specification In addition, in Type V construction, any StoTherm° ci° 4.1.3 StoPanelTM Impact ci°: StoPanelTM Impact ci° system listed in this report may be attached to the surface system is a prefabricated application by Kapture Prefab of of combustible exterior fire-resistance-rated assemblies the StoTherm°Impact ci°system.Sto materials, as listed in described in IBC Table 721.1(2) without changing the Table 6, must be installed in accordance with the assigned hourly rating of the assembly. The exterior wall specifications and installation instructions in Section 4.1.1. must have a minimum 10-foot (3048 mm) separation StoPanelTM Impact ci° system must be fabricated in distance from adjacent construction. accordance with project specification and StoPanelTM 4.7 Special Inspection: fabricator shop drawings for each project. For recognition under the IBC, special Inspections of the • StoPanel Impact ci° water-resistive barrier must be conducted in accordance • Specification with 2018 and 2015 IBC Section 1705.16(2012 IBC Section ESR-1748 I Most Widely Accepted and Trusted Page 3 of 9 1705.15). Refer to STO Corp. third-party inspection 7.0 IDENTIFICATION guidelines for verifying field preparation of materials. 7.1 Each container or package of the coating or reinforcing 5.0 CONDITIONS OF USE mesh used as part of the StoTherm°EIFS ci°systems The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM components must be labeled with the manufacturer's Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT name(STO Corp.) and address; the product name; lot ci°EIFS systems described in this report comply with, or are or batch number; quantity of material; storage suitable alternatives to what is specified in, those codes instructions;pot life; expiration date; and the evaluation listed in Section 1.0 of this report, subject to the following report number(ESR-1748). conditions: Sto insulation board must be labeled on the edge of 5.1 Installation must comply with this report, the each board with the STO Corp. name, the plant manufacturer's published installation instructions and identification number, and the evaluation report the applicable code. In the event of a conflict between number(ESR-1748). the manufacturer's instructions and this report, this Sto Turbostick and Sto Turbostick Mini adhesive report governs. must be labeled with the Sto Corporation company 5.2 The insulation board must be separated from the name and product name designation. building interior by a thermal barrier complying with the Other foam plastic insulation must be labeled in applicable code. accordance with the current ICC-ES evaluation report 5.3 Installation must be by applicators listed by Sto Corp. in which it is recognized, or in accordance with IBC StoPanelTM Classic ci°, StoPanelTM Impact ci°, Section 2603.2 or IRC Section R316.2, as applicable. StoPanelTM XPS StoPanelTM Classic NEXT ci°must be StoPanelTM Classic ci°, StoPanelTM Impact ci°, fabricated by Kapture Prefab and installed in StoPanelTM XPS StoPanelTM Classic NEXT ci° accordance with Sto instructions. prefabricated panels are produced by Kapture Prefab 5.4 Termination of the systems must not be less and shipped with a certificate of compliance that than 6 inches (152 mm) above finished grade in contains the project identification the panels were accordance with 2018 and 2015 IBC Section 2603.8 produced for, dates of panel fabrication and a (2012 IBC Section 2603.9)and IRC Section R318.4. statement that all components of the panels complies with the applicable requirements of ESR-1748. 6.0 EVIDENCE SUBMITTED 7.2 The report holder's contact information is the following: 6.1 Data in accordance with ASTM E2568 and ASTM STO CORP. E2273. 3800 CAMP CREEK PARKWAY 6.2 Data in accordance with the ICC-ES Acceptance BUILDING 1400, SUITE 120 Criteria for EIFS Clad Drainage Wall Assemblies ATLANTA, GEORGIA 30331 (AC235), dated January 2015 (editorially revised April (800)221-2397 2018). www.stocorp.com 6.3 Data in accordance with the ICC-ES Acceptance 7.3 The Additional Listee's contact information is the Criteria for Foam Plastic Insulation(AC12), dated June following: 2015(editorially revised October 2017). KAPTURE PREFAB 6.4 NFPA 285 and NFPA 268 test data, including 421 WEST ALAMEDA DRIVE engineering analysis. TEMPE, ARIZONA 85282 ESR-1748 I Most Widely Accepted and Trusted Page 4 of 9 TABLE 1—STOTHERM®cio SYSTEM COMPONENTS1,2 WATER-RESISTIVE ASTM C578 SYSTEM BARRIER INSULATION BOARD ADHESIVES BASE COATS FINISH TYPE 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Sto BTS Silo Sto BTS Silo Stolit StoTherm®cio Classic 81210 Sto AirSeal Type I° Sto BTS Xtra Sto BTS Xtra Stolit Milano3 80263 Sto VaporSeal Sto TurboStick Stolit X3 (see E5R-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Sto BTS Silo Sto BTS Silo StoTherm®cio Premier 81210 Sto AirSeal Type I° Sto BTS Xtra Sto BTS Xtra StoSilco Lit 80263 Sto VaporSeal Sto TurboStick (see E5R-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto Primer/Adhesive Sto DPR Sto Gold Coat Sto Primer/Adhesive-B Sto Primer/Adhesive Finish StoTherm®cie Essence 81210 Sto AirSeal Type I° Sto TurboStick Sto Primer/Adhesive-B Stolit Milano 80263 Sto VaporSeal (see E5R-1233) Sto TurboStick Mini Stolit X 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Sto BTS Silo Sto BTS Silo Stolit Lotusan StoTherm®cio Lotusan 81210 Sto AirSeal Type I° Sto BTS Xtra Sto BTS Xtra 80263 Sto VaporSeal Sto TurboStick (see E5R-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Stolit Sto Gold Coat Sto TurboStick Sto BTS Xtra Stolit Lotusan StoTherm®cio XPS 81210 Sto AirSeal Type X Sto TurboStick Mini Sto Primer/Adhesive Stolit Milano 80263 Sto VaporSeal Sto Primer/Adhesive-B Stolit X (see E5R-1233) 'All base coats are reinforced with the appropriate Sto Mesh product listed in Table 2. 2Sto Primer is an optional component of the systems listed above. 3Sto BTS Silo basecoat is not recognized for use with Stolit Milano and Stolit X finish. 4Reference Section 3.2(f)for alternate insulation board. TABLE 2—REINFORCING MESH PRODUCTS PRODUCT NO. PRODUCT NAME' NOMINAL WEIGHT, ozlyd'(glm') 80920E Sto Mesh 4.5(153) 80919 Sto Detail Mesh 4.2(142) 80985 Sto 6-oz.(170 g)Mesh 6.0(170) 80918 Sto Intermediate Mesh 11.0(373) 80921 Sto Armor Mat 15.0(509) 80922 Sto Armor Mat XX 20.0(678) 80921A Sto Cormer Mat 7.6(258) ,Other listed mesh products may be used for detail construction or to supplement impact resistance of the EIFS. ESR-1748 I Most Widely Accepted and Trusted Page 5 of 9 TABLE 3—WIND LOAD DESIGN' WIND LOAD FRAMING MEMBERS2 SHEATHING CAPACITY,psf (Pa) Metal SYSTEM Wood, Maximum Thickness Maximum Fastener min.size Min.Depth Min. Spacing Type inch Spacing3, Neg. Pos. (inches) (inches) Gage (inches) ( ) (inches) 2x4 16 Wood-based 3/8 8 20 36 Classic (nominal) Premier 31/2 18 16 Wood-based 3/8 8 38 60 Essence Classic 31/2 18 16 Gypsum 1/2 8 20 35 Premier Essence Lotusan StoPanelTM(See Table 6) 31/2 18 16 Gypsum 5/8 8 38 60 Essence StoPaneITM(See Table 6) Classic Premier Essence Lotusan(with Turbo Stick 6 18 16 Gypsum 5/8 6 40 50 Adhesive or Sto TurboStick Mini and Type I EPS) StoPanelTM(See Table 6) 6 18 16 Gypsum 5/8 6 63 58 StoTherm ci®XPS StoPaneITM(See Table 6) Classic Concrete or masonry substrates 54 54 Premier Lotusan For SI: 1 inch=25.4 mm,1 psf=0.0479 kPa. 'Applicable to all StoTherm®materials listed in Tables 1 and 2. 2Deflection limitation 1/24o,designed in accordance with applicable code. 3Fasteners must be No.6,flathead,corrosion-resistant screws[minimum 0.292-inch(7.4 mm)head diameter]. TABLE 4—ASSEMBLIES FOR USE IN TYPES I THROUGH IV CONSTRUCTION FRAMING MEMBERS58 INTERIOR SHEATHING'' EXTERIOR SHEATHING MAX. (TYPE X GYPSUM) (TYPE X GYPSUM) INSULATION Metal Max. Min. Max.Fastener Min. Max.Fastener BOARD SYSTEM' Min.Depth Min. Spacing Thickness Spacing Thickness Spacing THICKNESS, (inches) (inches) Gage (inches) (inch) (inches) (inch) (inches) 1 8 at perimeter 6 at perimeter Essence 31/2 18 16 /2 12 in field 12 /2 8 in field3 12 Lotusan StoPanelTM(See Table 6) Classic 31/2 18 166 1/2 64 5/8 6 at perimeter 12 Premier 8 in field3 Lotusan StoPanelTM See Table 6 StoTherm®ci Essence with Sto TurboStick,Sto TurboStick Mini,Sto 61/4 20 16 5/8 84 5/8 84 12 Prim er/Adh esive-B base coat and Stolit X finish StoPanelTA°See Table 6 1 e s s 8 at perimeter 8 at perimeter Classic with Turbo Stick adhesive and 31/2 18 16 /8 12 in field /8 12 in field 9 Type I EPS StoPanelTM See Table 6 e s s 8 at perimeter 8 at perimeter StoTherm®ci®XPS with Sto BTS Xtra 31/2 18 16 /8 12 in field /8 12 in field 6 base coat and Stolit finish StoPanelTM See Table 6 For SI: 1 inch=25.4 mm. 'All board joints backed by framing. 2Fasteners are minimum No.8,Type S,corrosion-resistant screws,with sufficient length to penetrate framing a minimum of%inch(9.5 mm). 3Fasteners are No.6 drywall screws having sufficient length to penetrate framing a minimum of%inch(9.5 mm). 4Fasteners are No.6 by 11/4-inch-long(31.7 mm),buglehead drywall screws. 5Stud cavities at floor levels are blocked with Owens Corning Thermafiber insulation,4 Ib/ft3(64 kg/m3)density,4 inches(102 mm)thick and 2 feet(610 mm)wide. 6Stud cavities must be filled with R-11 fiberglass insulation. 7AII joints must be taped and treated with joint compound.Intermediate fastener heads are treated with joint compound in accordance with ASTM C840 or GA216. 60penings must be framed with minimum 0.0428-inch-thick steel framing. 9Applicable to StoTherm®ci®and StoPanelTM systems listed in Tables 1,4 and 6,except for StoTherm®ci®and StoPanelTM systems using Stolit Milano and Stolit X finish,unless noted otherwise. ESR-1748 I Most Widely Accepted and Trusted Page 6 of 9 TABLE 5—FIRE-RESISTANCE-RATED ASSEMBLIES1,2 FRAMING MEMBERS INTERIOR SHEATHING EXTERIOR SHEATHING MAXIMUM FIRE- Min. Min. Max. Type Min. Max. Type Min. Max. EPS RESISTANCE Depth Gage Spacing Thickness Fastener Thickness Fastener INSULATION RATING (inches) (inches) (inch) Spacing (inch) Spacings BOARD (hrs) (inches) (inches) THICKNESS (inches) 8 o.c.on 6 at 1 31/2 18 16 Type XS 5/8 perimeter Type X 5/8 perimeter 4 gypsum 12 o.c.in gypsum 8 in field field' Two layers Base layer Two layers Base layer 2 31/2 18 16 of Type X 5/8 at 24 o.c. of Type X 5/8 at 24 o.c. 4 5 Face layer Face layer gypsum at 8 o.c.1 gypsum at 8 o.c.' For SI: 1 inch=25.4 mm. 'Applicable to all StoTherm®ci®and StoPanelTm materials listed in Table 1,except to StoTherm®ci®and StoPanelTM systems which use the Stolit Milano,Stolit X and Sto Turbo Stick or Sto TurboStick Mini adhesive. 2All board joints must be blocked 3Fasteners are minimum No.6,11/4-inch-long(32 mm),self-tapping,corrosion-resistant bugle head screws. 4Fasteners are No.6 drywall screws having sufficient length to penetrate framing a minimum of%inch(9.5 mm). 51nterior wallboard joints must be covered with tape and joint compound.Interior fastener heads are covered with joint compound in accordance with ASTM C840 or GA 216. 6Fasteners for the base layer of gypsum board are No.6,11/4-inch-long,self-tapping,corrosion-resistant bugle-head screws.Fasteners for the face layer are 17/8- inch-long,self-tapping,corrosion-resistant bugle-head screws. TABLE 6—STOPANELT" COMPONENTSI,2 WATER-RESISTIVE ASTM C578 SYSTEM BARRIER INSULATION ADHESIVES BASE COATS FINISH BOARD TYPE 80265-81636 Sto BTS Plus Sto BTS Plus Stolit Sto Gold Coat Type I Sto BTS Silo Sto BTS Silo Stolit Milano3 StoPanelTM Classic ci° 81210 Sto AirSeal Sto BTS Xtra Sto BTS Xtra Stolit X3 80263 Sto VaporSeal Sto TurboStick (see E5R1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Sto BTS Plus Stolit StoPanelTM Classic Sto Gold Coat Type I Sto BTS Silo Sto BTS Silo Stolit Milano3 NEXT ci° 81210 Sto AirSeal Sto BTS Xtra Sto BTS Xtra Stolit X3 80263 Sto VaporSeal Sto TurboStick Sto RFP (see E5R1233) Sto TurboStick Mini 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Type I Sto BTS Silo Sto BTS Silo StoSilco Lit StoPanelTM Impact ci'� 81210 Sto AirSeal Sto BTS Xtra Sto BTS Xtra 80263 Sto VaporSeal Sto TurboStick (see ESR-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Stolit Sto Gold Coat Type X Sto TurboStick Sto BTS Xtra Stolit Lotusan StoPanelTA° XPS 81210 Sto AirSeal Sto TurboStick Mini Sto Primer/Adhesive Stolit Milano 80263 Sto VaporSeal Sto Primer/Adhesive-B Stolit X (see E5R1233) 'All base coats are reinforced with the appropriate Sto Mesh product listed in Table 2. 2Sto Primer is an optional component of the systems listed above. 3Sto BTS Silo basecoat is not recognized for use with Stolit Milano and Stolit X finish. ESICC IMES Evaluation Report ESR-1748 LABC and LARC Supplement Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. EVALUATION SUBJECT: STOTHERM° ci°, STOPANELTM CLASSIC ci°, STOPANELTM IMPACT ci°, STOPANELTM XPS AND STOPANELTM CLASSIC NEXT ci® 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that StoTherm° ci°, StoPanelTM Classic ci®, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in ICC-ES evaluation report ESR-1748, have also been evaluated for compliance with the codes noted below as adopted by Los Angeles Department of Building and Safety(LADBS). ■ 2020 City of Los Angeles Building Code(LABC) ■ 2020 City of Los Angeles Residential Code(LARC) 2.0 CONCLUSIONS The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPaneIT"" Classic NEXT ci° systems, described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, comply with LABC Chapters 7, 14 and 26, and LARC Sections R316 and R703,subject to the conditions of use described in this report. 3.0 CONDITIONS OF USE The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems described in this evaluation report supplement must comply with all of the following conditions: • All applicable sections in the ICC-ES evaluation report ESR-1748. • The design, installation, conditions of use and labeling of the StoTherm° ci°, StoPanelTM Classic ci®, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelT"" Classic NEXT ci° systems are in accordance with the 2018 International Building Code° (2018 IBC) or 2018 International Residential Code° (2018 IRC) provisions, as applicable, noted in the ICC-ES evaluation report ESR-1748. • The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as applicable. This supplement expires concurrently with the evaluation report, reissued October 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i to any finding or other matter in this report,or as to any product covered by the report. mum Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 7 of 9 ESCC IMES Evaluation Report ESR-1748 CBC and CRC Supplement Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. EVALUATION SUBJECT: STOTHERM° ci°, STOPANELTM CLASSIC ci°, STOPANELTM IMPACT ci°, STOPANELTM XPS AND STOPANELTM CLASSIC NEXT ci° 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that StoTherm°ci°,StoPanelTM Classic ci°,StoPanelTM Impact 60, StoPanelTM XPS and StoPanelTM Classic NEXT ci°systems, described in ICC-ES evaluation report ESR-1748, have also been evaluated for compliance with the codes noted below. Applicable code edition(s): ■ 2019 California Building Code°(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD)and Division of State Architect(DSA), see Sections 2.1.1 and 2.1.2 below. ■ 2019 California Residential Code°(CRC) 2.0 CONCLUSIONS 2.1 CBC: The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, complies with 2019 CBC Chapter 14, provided the design and installation are in accordance with the 2018 International Building Code° (IBC) provisions respectively, noted in the main report and the additional requirements of CBC Chapters 14 and 17. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, complies with the 2019 CRC Chapter 7, provided the design and installation are in accordance with the 2018 International Residential Code° (IRC) provisions respectively, noted in the main report and the applicable provisions of the CRC. This supplement expires concurrently with the evaluation report, reissued October 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. 7 a Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 8 of 9 ESCC ICC-ES Evaluation Report ESR-1748 FBC Supplement Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. EVALUATION SUBJECT: STOTHERM° ci°, STOPANELTM CLASSIC ci°, STOPANELT"^ IMPACT ci°, STOPANELTM XPS AND STOPANELTM CLASSIC NEXT ci® 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in ICC-ES ICC-ES evaluation report ESR-1748, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2020 Florida Building Code—Building IN 2020 Florida Building Code—Residential 2.0 CONCLUSIONS The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, comply with the Florida Building Code—Building and Florida Building Code—Residential, provided the design and installation are in accordance with the 2018 International Building Code°provisions noted in the ICC-ES report under the following condition: Installation must meet the requirements of Sections 1403.8 and 2603.8 of the Florida Building Code—Building and Sections R318.7 and R318.8 of the Florida Building Code—Residential, as applicable. Use of the StoTherm°ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci°systems for compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building Code—Residential has not been evaluated and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the evaluation report, reissued October 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied to any finding or other matter in this report,or as to any product covered by the report. �s Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 9 of 9 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: SIKA CORPORATION Issued August 9,2020 201 Polito Avenue Lyndhurst, NJ 07071 (201) 568-9300 Quality Assurance: PRI Construction Materials, LLC (QUA9110) SCOPE Category: Roofing Subcategory: Waterproofing Code Edition: Florida Building Code, 7"' Edition (2020) including High-Velocity Hurricane Zones(HVHZ) Code Sections: 1504.3.1, 1507.15.2, 1515.1.1, 1515.1.4, 1519.16, 1523.1.1 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) LPI-045-02-01 ASTM D 7311/D 7311M 2010 PRI Construction Materials Technologies(TST5878) LPI-046-02-01 ASTM C 297 2010 PRI Construction Materials Technologies(TST5878) LPI-049-02-01 ANSI/FM 4474(B) 2011 TAS 114(D) 2011 PRI Construction Materials Technologies(TST5878) LPI-049-02-02 ANSI/FM 4474(B) 2011 TAS 114(D) 2011 PRI Construction Materials Technologies(TST5878) LPI-052-02-01 ASTM C 836 2015 PRI Construction Materials Technologies(TST5878) LPI-062-02-01 ANSI/FM 4474(B) 2011 TAS 114(D) 2011 PRI Construction Materials Technologies(TST5878) LPI-070-02-01.1 ASTM D 4541 2009e1 PRI Construction Materials Technologies(TST5878) LPI-072-02-01.1 ASTM D 4541 2009e1 PRI Construction Materials Technologies(TST5878) LPI-078-02-01.1 ASTM D 562 2010(2014) ASTM D 1475 2013 ASTM D 1644 2001(2017) ASTM E 96/E 96M 2015 PRI Construction Materials Technologies(TST5878) LPI-083-02-01 ASTM D 6083 2018 PRI Construction Materials Technologies(TST5878) LPI-083-02-01A ASTM D 4541 2009e1 SIKA14001.4 FL17440-R4 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems TECHNICAL SERVICES, LLC PRODUCT DESCRIPTIONS&APPLICATION Use Products Description Sika Bonding Primer Two-component,water-based, epoxy primer applied at a rate of 200-300 ftZ/gal depending on substrate profile and porosity Sikalastic DTE Primer Two-component,epoxy primer applied at a rate of 200 ftZ/gal Sikalastic EP Two-component,epoxy primer applied at a rate of 100-250 ftZ/gal depending on Primer Primer/Sealer substrate profile and porosity Sikalastic Concrete Single-component, low odor moisture-curing polyurethane resin applied at a rate Primer Lo-VOC of 225-375 ftZ/gal depending on substrate profile and porosity Sika Concrete Primer Two-component,solvent-based polyurethane primer applied at a rate of 225-375 ft/gal depending on substrate profile and porosity Cold applied,aliphatic,single component, moisture-triggered polyurethane resin Sikalastic 621 TC base and top coat applied with a 1/2-inch nap phenolic resin roller,spray,or squeegee applied Liquid-Applied Cold applied,aliphatic,single component,alkali resistant moisture-triggered Waterproofing Sikalastic 624 WP polyurethane base and top coat applied with a 1/2-inch nap phenolic resin roller, spray,or squeegee applied ASTM D 6083,Type I,cold applied,aliphatic,single component, moisture- Sikalastic 641 Lo-VOC triggered polyurethane base and top coat applied with a 1/2-inch nap phenolic resin roller,spray,or squeegee applied Sika Fleece 120 Non-woven,needle-punched polyester fleece reinforcement; Min.3-inch side laps Sika Fleece 140 and min.6-inch end laps; Embed into wet resin and apply wet roller to top to Reinforcement Sika Fleece 170 saturate Sika Reemat Premium Surface treated, randomly oriented glass fiber reinforcement; Min.2-inch overlapping seams; Embed into wet resin and apply wet roller to top to saturate Laticrete 254 Platinum Thin-Set Mortar Overburden MAPEI Ceramic Tile Applied with 1/4"x 3/8"x 1/4"notched trowel Attachment Mortar Versabond Fortified Thin-Set Mortar WATERPROOFING SYSTEMS System Component Detail with Sika Reemat Reinforcement Detail with Sika Fleece Reinforcement Base Coat: Sikalastic 621 TC 2 I applied at a rate of 35 ft/gal Roof Pro 20 Reinforcement: Sika Reemat Premium I TC System Sikalastic 621 TC applied at a rate of 53 ft2/gal with silica Top Coat: sand broadcast at a rate of 2.75 Ibs/100 ftZ into wet top coat SIKA14001.4 FL17440-R4 Page 2 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK SIK CORPORATION Sikalastic RoofPro Roofing and Waterpp roofing Systems TECHNICAL SERVICES, LLC System Component Detail with Sika Reemat Reinforcement Detail with Sika Fleece Reinforcement Base Coat: Sikalastic 621 TC applied at a rate of 35 ft2/gal Reinforcement: Sika Reemat Premium RoofPro 25 TC System Intermediate Sikalastic 621 TC Coat: applied at a rate of 53 ft2/gal Sikalastic 621 TC applied at a rate of 53 ft2/gal with silica Top Coat: sand broadcast at a rate of 2.75 Ibs/100 ft2 into wet top coat EL Base Coat: Sikalastic 624 WP 2 Sikalastic 624 WP 2 applied at a rate of 35 ft/gal applied at a rate of 32 ft2/gal Reinforcement: Sika Reemat Premium Sika Fleece 140 RoofPro 20 WP System Intermediate Sikalastic 624 WP Sikalastic 624 WP Coat: applied at a rate of 40 ft2/gal applied at a rate of 45 ft2/gal Sikalastic 624 WP applied at a rate of 107 ft2/gal with silica sand broadcast at a rate of 50 Top Coat: Ibs/100 ft2 into wet top coat Base Coat: Sikalastic 624 WP Sikalastic 624 WP 2 applied at a rate of 35 ft2/gal applied at a rate of 24 ft2/gal Reinforcement: Sika Reemat Premium Sika Fleece 170 RoofPro 25 Two(2)coats of Sikalastic 624 WP applied WP System Intermediate at a rate of 53 ft2/gal. Allow 12 hours cure Sikalastic 624 WP Coat: time between first and second coat. applied at a rate of 40 ft2/gal 7TOPSikalastic 624 WP applied at a rate of 107 ft2/gal with silica sand broadcast at a rate of 50 Coat: Ibs/100 ft2 into wet top coat Base Coat: Sikalastic 641 Lo-VOC 2 Sikalastic 641 Lo-VOC 2 641 Lo-VOC applied at a rate of 32 ft/gal applied at a rate of 35 ft/gal RoofPro 15 Reinforcement: Sika Reemat Premium Sika Fleece 120 System Sikalastic 641 Lo-VOC Sikalastic 641 Lo-VOC Top Coat: applied at a rate of 80 ft2/gal applied at a rate of 64 ft2/gal Base Coat: Sikalastic 641 Lo-VOC 2 Sikalastic 641 Lo-VOC 2 641 Lo-VOC applied at a rate of 32 ft2/gal applied at a rate of 32 ft/gal RoofPro 20 Reinforcement: Sika Reemat Premium Sika Fleece 140 System Sikalastic 641 Lo-VOC Sikalastic 641 Lo-VOC Top Coat: applied at a rate of 53 ft2/gal applied at a rate of 53 ft2/gal Base Coat: Sikalastic 641 Lo-VOC 2 Sikalastic 641 Lo-VOC 2 applied at a rate of 32 ft/gal applied at a rate of 24 ft/gal 641 Lo-VOC Reinforcement: Sika Reemat Premium Sika Fleece 170 RoofPro 25 System Two(2)coats of Sikalastic 641 Lo-VOC applied at a rate of 69 ft2/gal. Allow 12 Sikalastic 641 Lo-VOC Top Coat: hours cure time between first and second applied at a rate of 47 ft2/gal coat. SIKA14001.4 FL17440-R4 Page 3 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems TECHNICAL SERVICES, LLC APPROVED ASSEMBLIES The following notes shall be observed when using the waterproofing systems from the tables below. 1. Maximum Design Pressures were calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS section of this evaluation when using the table(s) below. 3. Refer to PRODUCT DESCRIPTION&APPLICATION section of this report for installation detail when the information is not explicitly stated for the selected roof system. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. Assemblies with Adhered Membranes over Concrete Deck(New or Existing) Max. SyNttem Deck Detail Watero. proofing System Overburden DesiPressgn re (psf) Min 2500 psi concrete primed Minimum 2500 psi, with Sika Bonding Primer, RoofPro 20 WP System 2-inch thick -367.5 C-1 Sikalastic DTE Primer, or RoofPro 25 WP System structural concrete (Lim. 9) Sikalastic EP Primer/Sealer,or Sika Concrete Primer Lo-VOC poured in place Minimum 12"x 12"tiles complying with Min 2500 psi concrete primed ANSI A137.1 secured in with Sika Bonding Primer, Laticrete 254 Platinum C-2 Sikalastic DTE Primer, r RofPro 20 WP System thin-set mortar, 495 Sikalastic EP Primer/Sealer,or or RoofPro 25 WP System Versabond Fortified (Lim. 9) Sika Concrete Primer Lo-VOC Thin-Set Mortar,or MAPEI Ceramic Tile Mortar RoofPro 20 TC System, Min 2500 psi concrete primed RoofPro 25 TC System, with Sika Bonding Primer, RoofPro 20 WP System, Drainage medium C-3 Sikalastic DTE Primer, RoofPro 25 WP System followed by -502.5 Sikalastic EP Primer/Sealer,or (without top coat), min.24-inch (Lim. 9) Sika Concrete Primer Lo-VOC 641 Lo-VOC RoofPro 15 System, deep soil medium 641 Lo-VOC RoofPro 20 System or 641 Lo-VOC RoofPro 25 System Min 2500 psi concrete primed RoofPro 20 TC System, with Sika Bonding Primer, RoofPro 25 TC System, C-4 Sikalastic DTE Primer, 641 Lo-VOC RoofPro 15 System, -502.5 Sikalastic EP Primer/Sealer, 641 Lo-VOC RoofPro 20 System or (Lim. 9) Sika Concrete Primer,or 641 Lo-VOC RoofPro 25 System Sika Concrete Primer Lo-VOC SIKA14001.4 FL17440-R4 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.4.1.5 and 2603.6. 4. In the HVHZ, fastener spacing for insulation attachment is determined using a Minimum Characteristic Force (F') of 275 Ibf as demonstrated via testing to TAS 105. If the field tested fastener value is below 275 Ibf, then insulation attachment shall not be acceptable. 5. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener resistance value and the MDP for the specified roof system. It is permissible for a qualified professional to submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is found less than required. 6. In the HVHZ, if mechanical attachment through the lightweight insulating concrete to the structural deck is proposed, a field fastener withdrawal test shall be conducted in compliance with TAS 105 to determine equivalent or increased attachment densities. Revised fastener densities shall be submitted utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137. 7. For assemblies containing mechanical attachment, the allowable uplift pressure for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. For perimeter and corner roof zones 2 and 3, the attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in these areas. In the HVHZ, calculations shall be conducted in compliance with RAS 117 and/or RAS 137. Outside the HVHZ, commonly used standards include RAS 117, FM LPDS 1-29, or ANSI/SPRI WD-1. 8. Reroofing applications shall be examined in accordance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened systems, a field withdrawal resistance test (TAS 105 in the HVHZ; ANSI/SPRI FX-1 or TAS 105 in the non-HVHZ) shall be conducted by a qualified professional to ensure the fastener meets the minimum design load requirements of the system. For adhered systems, a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1-52, ANSI/SPRI IA-1, or TAS 124 in the non-HVHZ) shall be conducted to confirm conformance of the existing to the minimum design loads. 9. For assemblies containing fully adhered or ribbon adhered attachment, or where extrapolation of the roof system is not permitted, the MDP for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16 without augmentation. 10. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 11. The minimum roof slope shall be 1/4:12 for new construction. 12. The AHJ may require integrity flood testing (ASTM D 5957) or Electric Field Vector Mapping tests of all waterproofing systems prior to placement of the overburden material. Testing, if required, should be conducted by a qualified design professional. In the HVHZ,the waterproofing system shall be flood tested in accordance with Section 1519.16.6. 13. All products listed in this report shall be manufactured under a quality assurance programs in compliance with Rule 61G20-3. SIKA14001.4 FL17440-R4 Page 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 71" Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. "" - 2020.08.09 � RY R. p �, ti• = 16:38:26 No 74021 -04'00' STATE OF :441 i�,�'• p ��� Zachary R. Priest, P.E. O R ��••'�jN�.` Florida Registration No. 74021 '#i`,S1S';pNA ��%N`` Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT SIKA14001.4 FL17440-R4 Page 6 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 04 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION GAF Evaluation Report 01506.09.05-1147 1 Campus Drive FL5293-R46 Parsippany, NJ 07054 Date of Issuance: 11/09/2005 (800)766-3411 Revision 47:06/07/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7t' Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: EverGuardO TPO Single-Ply Roof Membrane Systems for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 156-page Appendix. Prepared by: Robert J.M. Nieminen °�` ` �P.E. � �' a r p The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 �"n "`'vC' Nieminen,P.E.on 06/07/2021. This does not serve as an t electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC,LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Single Ply Roof Systems Compliance Statement: EverGuard® TPO Single-Ply Roof Membrane Systems, as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.6 Physical properties ASTM G155 2013 1504.7 Impact resistance FM 4470 2016 1507.10.2 Material standard ASTM D2178 2015 1507.10.2 Material standard ASTM D4601 2012 1507.10.2 Material standard ASTM D4897 2009 1507.11.2 Material standard ASTM D6163 2015 1507.11.2 Material standard ASTM D6164 2011 1507.13.2 Material standard ASTM D6878 2013 3. REFERENCES: Entity Exam Reference Date Entity Exam Reference Date ACRC(TST4671) TAS 114 06-035 10/18/2006 FM App(TST1867) FM 4474 3056207 02/09/2016 ACRC(TST4671) TAS 114 07-005 01/17/2007 FM App(TST1867) FM 4474 3055167 02/10/2016 ACRC(TST4671) TAS 114 07-024 03/01/2007 FM App(TST1867) FM 4474 RR204005 04/13/2016 ACRC(TST4671) TAS 114 07-016 04/19/2007 FM App(TST1867) FM 4474 RR205159 05/05/2016 ACRC(TST4671) TAS 114 07-017 04/19/2007 FM App(TST1867) FM 4474 RR205192 05/09/2016 ACRC(TST4671) TAS 114 07-025 05/02/2007 FM App(TST1867) FM 4474 RR205233 06/15/2016 ACRC(TST4671) TAS 114 07-026 05/03/2007 FM App(TST1867) FM 4474 RR205846 07/21/2016 ACRC(TST4671) TAS 114 07-027 05/04/2007 FM App(TST1867) FM 4474 RR20S474 08/31/2016 ACRC(TST4671) TAS 114 07-042 08/31/2007 FM App(TST1867) FM 4474 RR206198 09/01/2016 ACRC(TST4671) TAS 114 07-043 09/05/2007 FM App(TST1867) FM 4474 RR206353 09/07/2016 ACRC(TST4671) TAS 114 07-045 09/06/2007 FM App(TST1867) FM 4474 RR206620 09/12/2016 ACRC(TST4671) TAS 114 07-046 09/06/2007 FM App(TST1867) FM 4474 RR206351 10/21/2016 ACRC(TST4671) TAS 114 07-048 09/07/2007 FM App(TST1867) FM 4474 3055491 12/05/2016 ACRC(TST4671) TAS 114 07-049 09/10/2007 FM App(TST1867) FM 4474 3058483 12/09/2016 ACRC(TST4671) TAS 114 07-080 01/03/2008 FM App(TST1867) FM 4474 3056728LTR 12/23/2016 ACRC(TST4671) TAS 114 08-022 04/17/2008 FM App(TST1867) FM 4470 3056822 LTR 01/04/2017 ACRC(TST4671) TAS 114 08-030 04/05/2008 FM App(TST1867) FM 4474 RR208456 02/13/2017 ACRC(TST4671) TAS 114 08-023 04/17/2008 FM App(TST1867) FM 4474 3061218 05/10/2017 ACRC(TST4671) TAS 114 08-033 04/19/2008 FM App(TST1867) FM 4474 3061218LTR 05/16/2017 ACRC(TST4671) TAS 114 08-032 04/19/2008 FM App(TST1867) FM 4474 RR209927 06/23/2017 ACRC(TST4671) TAS 114 11-004 03/21/2011 FM App(TST1867) FM 4474 RR210305 07/13/2017 ACRC(TST4671) TAS 114 11-011 03/24/2011 FM App(TST1867) FM 4474 RR213506 03/28/2018 ACRC(TST4671) TAS 114 11-012 04/06/2011 FM App(TST1867) FM 4474 RR212730 04/05/2018 ACRC(TST4671) TAS 114 11-013 04/06/2011 FM App(TST1867) FM 4474 PR449797 04/24/2018 ACRC(TST4671) TAS 114 11-019 04/08/2011 FM App(TST1867) FM 4474 RR213333 04/25/2018 ACRC(TST4671) TAS 114 11-020 04/08/2011 FM App(TST1867) FM 4474 3056933 07/19/2018 ACRC(TST4671) TAS 114 11-021 04/11/2011 FM App(TST1867) FM 4474 3061784 07/25/2018 ACRC(TST4671) TAS 114 11-040 08/05/2011 FM App(TST1867) FM 4474 RR215107-267 09/27/2018 ACRC(TST4671) TAS 114 11-041 08/05/2011 FM App(TST1867) FM 4474 3055904 10/25/2018 ACRC(TST4671) TAS 114 11-056 09/30/2011 FM App(TST1867) FM 4474 RR215191-267 11/07/2018 ACRC(TST4671) TAS 114 12-008 04/10/2012 FM App(TST1867) FM 4474 RR215193-267 11/08/2018 ACRC(TST4671) TAS 114 12-012 04/23/2012 FM App(TST1867) FM 4474 RR217564-267 02/05/2019 ACRC(TST4671) TAS 114 12-013 04/23/2012 FM App(TST1867) FM 4474 PR453601-R1 11/15/2019 ACRC(TST4671) TAS 114 12-014 04/23/2012 FM App(TST1867) Criticality PR452423 02/06/2020 ACRC(TST4671) TAS 114 12-016 04/24/2012 FM App(TST1867) FM 4474 RR221253-267 02/07/2020 ACRC(TST4671) TAS 114 12-019 04/25/2012 FM App(TST1867) Criticality PR452971 02/19/2020 ACRC(TST4671) TAS 114 12-024 05/09/2012 FM App(TST1867) FM 4474 RR222755-267 03/10/2020 ACRC(TST4671) TAS 114 12-025 05/09/2012 FM App(TST1867) FM 4474 PR450754 04/03/2020 ACRC(TST4671) TAS 114 12-029 05/23/2012 FM App(TST1867) FM 4474 PR455417 09/30/2020 ACRC(TST4671) TAS 114 12-030 05/23/2012 FM App(TST1867) FM 4474 PR455417 R2 12/23/2020 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 47:06/07/2021 Page 2 of 6 *NEMO I etc. Entity Exam Reference Date Entity Exam Reference Date ACRC(TST4671) TAS 114 11-042-R1 01/27/2012 FM App(TST1867) FM 4474 RR227079 03/10/2021 ACRC(TST4671) TAS 114 12-033 08/10/2012 FM App(TST1867) Traceability PR459034 03/24/2021 ACRC(TST4671) TAS 114 12-036 08/13/2012 FM App(TST1867) FM 4474 PR458073 04/08/2021 ACRC(TST4671) TAS 114 12-018-R1 01/30/2013 Intertek(TST1558) TAS 114 G9819.01-109-44 08/15/2017 ACRC(TST4671) TAS 114 08-022-R1 01/15/2015 IRT(TST7408) TAS 114 02-008 01/18/2002 ACRC(TST4671) TAS 114 11-056-112 01/23/2015 IRT(TST7408) TAS 114 03-0728 02/17/2004 ACRC(TST4671) TAS 114 16-002 03/04/2016 IRT(TST7408) TAS 114 04-012 02/18/2004 ACRC(TST4671) TAS 114(D) 20-016 11/11/2020 IRT(TST7408) TAS 114 04-019 04/26/2004 ACRC(TST4671) TAS 114(D) 20-017 11/11/2020 NEMO(TST6049) FM 4474 SC16825.12.17-3A 01/01/2018 ACRC(TST4671) TAS 114(D) 20-019 11/13/2020 NEMO(TST6049) Physicals 4q-GAF-I9-SSMBB-03.A 05/13/2019 ACRC(TST4671) TAS 114(D) 20-021 11/13/2020 PRI(TST5878) ASTM C1289 GAF-373-02-01 10/15/2012 ACRC(TST4671) TAS 114(D) 20-022 11/16/2020 PRI(TST5878) FM 4474 GAF-043-02-03 09/16/2013 ACRC(TST4671) TAS 114(D) 20-023 11/16/2020 PRI(TST5878) FM 4474 GAF-043-02-04 09/16/2013 ACRC(TST4671) TAS 114(1) 21-006 03/16/2021 PRI(TST5878) ASTM D6878 GAF-423-02-01 10/21/2013 ATI(TST1558) TAS 114 H-3320.01-109-44 08/10/2017 PRI(TST5878) ASTM D6878 GAF-421-02-01 10/22/2013 ATI(TST1558) TAS 114 H-3314.01-109-44 08/14/2017 PRI(TST5878) ASTM D6878 GAF-422-02-01 10/22/2013 ATI(TST1558) TAS 114 H-3315.01-109-44 08/14/2017 PRI(TST5878) ASTM D6878 GAF-424-02-01 11/11/2013 ATI(TST1558) TAS 114 H-3317.01-309-44 08/14/2017 PRI(TST5878) ASTM D6878 GAF-425-02-01 11/11/2013 ATI(TST1558) TAS 114 H-3318.01-109-44 08/14/2017 PRI(TST5878) Criticality GAF-462-02-02 11/18/2013 ATI(TST1558) TAS 114 H-0730.01-109-44 08/16/2017 PRI(TST5878) FM 4474 GAF-457-02-02 01/20/2014 ERD(TST6049) TAS 114 SC8580.11.15-4 11/09/2015 PRI(TST5878) FM 4474 GAF-457-02-04 01/24/2014 ERD(TST6049) FM 4474 SC8580.11.15-2 11/18/2015 PRI(TST5878) FM 4474 GAF-457-02-06 01/24/2014 ERD(TST6049) Criticality SC16505.17 09/22/2017 PRI(TST5878) FM 4474 GAF-457-02-07 01/24/2014 ERD(TST6049) FM 4474 SC16825.12.17-1 12/31/2017 PRI(TST5878) FM 4474 GAF-457-02-08 01/24/2014 ERD(TST6049) FM 4474 SC16825.12.17-3B 12/31/2017 PRI(TST5878) Rupture GAF-435-02-01 01/29/2014 F-TEC(TST7393) TAS 114 08-050183 06/26/2008 PRI(TST5878) FM 4474 GAF-435-02-07 01/29/2014 F-TEC(TST7393) TAS 114 08-050184 06/26/2008 PRI(TST5878) FM 4474 GAF-435-02-08 01/29/2014 F-TEC(TST7393) TAS 114 08-070133 08/04/2008 PRI(TST5878) FM 4474 GAF-435-02-09 01/29/2014 F-TEC(TST7393) TAS 114 08-050185 10/14/2008 PRI(TST5878) FM 4474 GAF-435-02-10 01/29/2014 F-TEC(TST7393) TAS 114 08-072805 02/16/2009 PRI(TST5878) FM 4474 GAF-435-02-11 01/29/2014 FM App(TST1867) FM 4470 3003617 12/20/1999 PRI(TST5878) FM 4474 GAF-506-02-06 03/06/2014 FM App(TST1867) FM 4470 3009026 06/18/2002 PRI(TST5878) FM 4474 GAF-506-02-08 03/06/2014 FM App(TST1867) FM 4470 3013861 03/28/2003 PRI(TST5878) FM 4474 GAF-506-02-10 03/06/2014 FM App(TST1867) FM 4470 3014692 08/05/2003 PRI(TST5878) FM 4474 GAF-510-02-02 04/08/2014 FM App(TST1867) FM 4470 3014955 01/22/2004 PRI(TST5878) FM 4474 GAF-510-02-04 04/08/2014 FM App(TST1867) FM 4470 3012721 02/11/2004 PRI(TST5878) FM 4474 GAF-510-02-05 04/08/2014 FM App(TST1867) FM 4470 3015029 02/19/2004 PRI(TST5878) FM 4474 GAF-511-02-02 04/08/2014 FM App(TST1867) FM 4470 3015578 03/12/2004 PRI(TST5878) FM 4474 GAF-506-02-11 04/14/2014 FM App(TST1867) FM 4470 3020588 03/24/2004 PRI(TST5878) FM 4474 GAF-506-02-12 04/14/2014 FM App(TST1867) FM 4470 3019881 03/20/2004 PRI(TST5878) FM 4474 GAF-506-02-13 04/14/2014 FM App(TST1867) FM 4470 3016068 04/02/2004 PRI(TST5878) FM 4474 GAF-506-02-14 04/14/2014 FM App(TST1867) FM 4470 3013861 05/21/2004 PRI(TST5878) FM 4474 GAF-506-02-01 04/22/2014 FM App(TST1867) FM 4470 3105578 05/12/2004 PRI(TST5878) FM 4474 GAF-514-02-01 05/12/2014 FM App(TST1867) FM 4470 3014955 01/28/2005 PRI(TST5878) FM 4474 GAF-514-02-03 05/12/2014 FM App(TST1867) FM 4470 3022136 03/17/2005 PRI(TST5878) FM 4474 GAF-514-02-04 05/12/2014 FM App(TST1867) FM 4470 3020681 09/01/2005 PRI(TST5878) FM 4474 GAF-514-02-05 05/12/2014 FM App(TST1867) FM 4470 3024051 03/28/2006 PRI(TST5878) FM 4474 GAF-514-02-07 05/12/2014 FM App(TST1867) FM 4470 797-02093-267 04/26/2006 PRI(TST5878) FM 4474 GAF-514-02-08 05/12/2014 FM App(TST1867) FM 4470 3023458 07/18/2006 PRI(TST5878) FM 4474 GAF-516-02-01 05/13/2014 FM App(TST1867) FM 4470 3028039 09/11/2006 PRI(TST5878) FM 4474 GAF-516-02-03 05/13/2014 FM App(TST1867) FM 4470 3027159 10/03/2006 PRI(TST5878) FM 4474 GAF-516-02-02 06/06/2014 FM App(TST1867) FM 4470 3026149 02/05/2007 PRI(TST5878) FM 4474 GAF-525-02-02 06/23/2014 FM App(TST1867) FM 4470 3026964 07/25/2007 PRI(TST5878) FM 4474 GAF-525-02-03 06/23/2014 FM App(TST1867) FM 4470 3028857 11/02/2007 PRI(TST5878) FM 4474 GAF-462-02-09 07/01/2014 FM App(TST1867) FM 4470 3030199 11/05/2007 PRI(TST5878) FM 4474 GAF-462-02-10 07/01/2014 FM App(TST1867) FM 4470 3030813 11/05/2007 PRI(TST5878) FM 4474 GAF-462-02-11 07/01/2014 FM App(TST1867) FM 4470 3031262 11/30/2007 PRI(TST5878) FM 4474 GAF-524-02-02 07/01/2014 FM App(TST1867) FM 4470 3030292 02/25/2008 PRI(TST5878) FM 4474 GAF-524-02-03 07/01/2014 FM App(TST1867) FM 4470 797-03825-267 07/21/2008 PRI(TST5878) FM 4474 GAF-524-02-05 07/01/2014 FM App(TST1867) FM 4470 3033314 08/26/2008 PRI(TST5878) FM 4474 GAF-540-02-02 08/06/2014 FM App(TST1867) FM 4470 3034749 10/16/2008 PRI(TST5878) FM 4474 GAF-540-02-03 08/06/2014 FM App(TST1867) FM 4470 3032856 11/24/2008 PRI(TST5878) FM 4474 GAF-540-02-04 08/06/2014 FM App(TST1867) FM 4470 3033135 11/24/2008 PRI(TST5878) FM 4474 GAF-538-02-02 08/13/2014 FM App(TST1867) FM 4470 3033862 12/24/2008 PRI(TST5878) FM 4474 GAF-538-02-03 08/13/2014 FM App(TST1867) FM 4470 3034394 02/27/2009 PRI(TST5878) FM 4474 GAF-532-02-01 08/22/2014 FM App(TST1867) FM 4470 3033121 04/13/2009 PRI(TST5878) FM 4474 GAF-524-02-05 08/27/2014 FM App(TST1867) FM 4470 3035300 05/06/2009 PRI(TST5878) FM 4474 GAF-549-02-01 08/08/2014 FM App(TST1867) FM 4470 3036614 06/09/2009 PRI(TST5878) FM 4474 GAF-538-02-04 09/02/2014 FM App(TST1867) FM 4470 3034310 06/15/2009 PRI(TST5878) FM 4474 GAF-559-02-11 10/16/2014 FM App(TST1867) FM 4470 3036141 08/10/2009 PRI(TST5878) FM 4474 GAF-559-02-12 10/16/2014 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL5293-11146 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 47:06/07/2021 Page 3 of 6 *NEMO I etc. Entity Exam Reference Date Entity Exam Reference Date FM App(TST1867) FM 4470 3037820 04/30/2010 PRI(TST5878) FM 4474 GAF-559-02-13 10/16/2014 FM App(TST1867) FM 4470 797-059797-267 08/18/2010 PRI(TST5878) FM 4474 GAF-559-02-14 10/16/2014 FM App(TST1867) FM 4470 3038215 09/02/2010 PRI(TST5878) FM 4474 GAF-559-02-15 10/16/2014 FM App(TST1867) FM 4470 797-05901-267 10/01/2010 PRI(TST5878) FM 4474 GAF-559-02-16 10/16/2014 FM App(TST1867) FM 4470 797-06003-267 11/11/2010 PRI(TST5878) FM 4474 GAF-559-02-18 10/16/2014 FM App(TST1867) FM 4470 3038318 12/10/2010 PRI(TST5878) FM 4474 GAF-538-02-05 12/03/2014 FM App(TST1867) FM 4470 797-06178-267 02/07/2011 PRI(TST5878) ASTM D6878 GAF-584-02-01 11/20/2015 FM App(TST1867) FM 4470 3040234 02/23/2011 PRI(TST5878) ASTM D6878 GAF-585-02-01 11/20/2015 FM App(TST1867) FM 4470 3040377 03/08/2011 PRI(TST5878) ASTM D6878 GAF-586-02-01 11/20/2015 FM App(TST1867) FM 4470 3041685 03/24/2011 PRI(TST5878) FM 4474 GAF-453-02-05 05/06/2016 FM App(TST1867) FM 4470 797-06254-267 03/24/2011 PRI(TST5878) FM 4474 GAF-453-02-09 05/06/2016 FM App(TST1867) FM 4470 3041535 06/08/2011 PRI(TST5878) Criticality GAF-653-02-01 10/20/2016 FM App(TST1867) FM 4470 797-06537-267 06/13/2011 PRI(TST5878) FM 4474 GAF-653-02-04 10/20/2016 FM App(TST1867) FM 4470 797-06538-267 06/13/2011 PRI(TST5878) FM 4474 GAF-746-02-01 12/14/2016 FM App(TST1867) FM 4470 3041746 08/17/2011 PRI(TST5878) FM 4474 GAF-746-02-02 12/14/2016 FM App(TST1867) FM 4470 797-06894-267 11/02/2011 PRI(TST5878) FM 4474 GAF-746-02-05 12/14/2016 FM App(TST1867) FM 4470 3038278 11/18/2011 PRI(TST5878) FM 4474 GAF-746-02-06 12/14/2016 FM App(TST1867) FM 4470 3042905 01/10/2012 PRI(TST5878) FM 4470 GAF-755-02-01 02/02/2017 FM App(TST1867) FM 4470 797-07041-267 02/27/2012 PRI(TST5878) FM 4474 GAF-755-02-02 02/02/2017 FM App(TST1867) FM 4470 797-07183-267 03/01/2012 PRI(TST5878) FM 4474 GAF-755-02-03 02/02/2017 FM App(TST1867) FM 4470 3044506 03/28/2012 PRI(TST5878) FM 4474 GAF-755-02-04 02/02/2017 FM App(TST1867) FM 4470 797-07331-267 04/13/2012 PRI(TST5878) ASTM D6878 GAF-700-02-01 03/10/2017 FM App(TST1867) FM 4470 3044862 05/11/2012 PRI(TST5878) ASTM D2178 MSA-039-02-01 09/27/2017 FM App(TST1867) FM 4470 797-07455-267 05/31/2012 PRI(TST5878) ASTM D2178 MSA-039-02-02 09/27/2017 FM App(TST1867) FM 4470 797-07474-267 06/11/2012 PRI(TST5878) FM 4474 GAF-782-02-01 08/24/2017 FM App(TST1867) FM 4470 797-07476-267 06/21/2012 PRI(TST5878) FM 4474 GAF-782-02-02 08/30/2017 FM App(TST1867) FM 4470 3045789 07/12/2012 PRI(TST5878) FM 4474 GAF-776-02-02 10/04/2017 FM App(TST1867) FM 4470 3045166 07/24/2012 PRI(TST5878) Criticality GAF-793-02-01 12/08/2017 FM App(TST1867) FM 4470 3045863 08/16/2012 PRI(TST5878) FM 4474 GAF-793-02-02 12/08/2017 FM App(TST1867) FM 4470 3041749 08/23/2012 PRI(TST5878) FM 4474 GAF-793-02-04 12/08/2017 FM App(TST1867) FM 4470 3046328 09/13/2012 PRI(TST5878) FM 4474 GAF-835-02-02 02/19/2018 FM App(TST1867) FM 4470 3041769 09/27/2012 PRI(TST5878) FM 4474 GAF-834-02-01 02/28/2018 FM App(TST1867) FM 4470 797-07744-267 10/17/2012 PRI(TST5878) FM 4474 GAF-835-02-03 02/28/2018 FM App(TST1867) FM 4470 797-07885-267 11/21/2012 PRI(TST5878) FM 4474 GAF-835-02-04 02/28/2018 FM App(TST1867) FM 4470 3046054 12/21/2012 PRI(TST5878) FM 4474 GAF-833-02-01 03/02/2018 FM App(TST1867) FM 4470 797-08216-267 04/11/2013 PRI(TST5878) FM 4474 GAF-833-02-02 03/02/2018 FM App(TST1867) FM 4470 3048122 04/29/2013 PRI(TST5878) FM 4474 GAF-836-02-01 03/02/2018 FM App(TST1867) FM 4470 797-08217-267 05/01/2013 PRI(TST5878) FM 4474 GAF-836-02-02 03/02/2018 FM App(TST1867) FM 4470 797-08264-267 05/23/2013 PRI(TST5878) FM 4474 GAF-836-02-03 03/02/2018 FM App(TST1867) FM 4470 3047237 07/15/2013 PRI(TST5878) FM 4474 GAF-836-02-04 03/02/2018 FM App(TST1867) FM 4470 3047636 08/08/2013 PRI(TST5878) FM 4474 GAF-858-02-05 04/27/2018 FM App(TST1867) FM 4474 797-08873-267 11/26/2013 PRI(TST5878) FM 4474 GAF-858-02-01 05/01/2018 FM App(TST1867) FM 4474 3048066 12/13/2013 PRI(TST5878) FM 4474 GAF-858-02-02 05/01/2018 FM App(TST1867) FM 4474 3041749 12/30/2013 PRI(TST5878) FM 4474 GAF-858-02-03 05/01/2018 FM App(TST1867) FM 4474 797-09116-267 01/24/2014 PRI(TST5878) FM 4474 GAF-858-02-04 05/01/2018 FM App(TST1867) FM 4474 797-09234-267 03/11/2014 PRI(TST5878) FM 4474 GAF-858-02-06 05/01/2018 FM App(TST1867) FM 4474 797-09317-267 04/18/2014 PRI(TST5878) FM 4474 GAF-834-02-03 05/11/2018 FM App(TST1867) FM 4474 797-09493-267 05/27/2014 PRI(TST5878) ASTM D6878 GAF-870-02-01 02/15/2019 FM App(TST1867) FM 4474 797-09495-267 05/27/2014 PRI(TST5878) FM 4474 GAF-902-02-02 02/27/2019 FM App(TST1867) FM 4474 797-09573-267 06/13/2014 PRI(TST5878) FM 4474 GAF-926-02-02 07/17/2019 FM App(TST1867) FM 4474 797-09497-267 06/23/2014 PRI(TST5878) FM 4474 376T0014 08/09/2019 FM App(TST1867) FM 4474 797-09594-267 06/24/2014 PRI(TST5878) FM 4474 376T0016 08/09/2019 FM App(TST1867) FM 4474 797-09635-267 07/16/2014 PRI(TST5878) FM 4474 376T0017 08/09/2019 FM App(TST1867) FM 4474 797-09892-267 10/30/2014 PRI(TST5878) FM 4474 376T0025 09/06/2019 FM App(TST1867) FM 4474 797-10123-283 12/17/2014 PRI(TST5878) FM 4474 376T0026 09/06/2019 FM App(TST1867) FM 4474 797-10153-267 12/19/2014 PRI(TST5878) Criticality 376T0006-1 01/18/2021 FM App(TST1867) FM 4474 797-10210-267 02/05/2015 PRI(TST5878) Criticality 376T0006-3 09/06/2019 FM App(TST1867) FM 4474 797-10211-267 02/05/2015 PRI(TST5878) FM 4474 376T0027 09/19/2019 FM App(TST1867) FM 4474 797-10212-267 02/05/2015 PRI(TST5878) ASTM D6878 GAF-904-02-01 10/09/2019 FM App(TST1867) FM 4474 797-RR20018 02/23/2015 PRI(TST5878) ASTM D6878 GAF-889-02-01 11/01/2019 FM App(TST1867) FM 4474 RR200320 04/07/2015 PRI(TST5878) FM 4474 376T0097 10/26/2020 FM App(TST1867) FM 4474 RR200321 04/07/2015 PRI(TST5878) FM 4474 376T0093 01/26/2021 FM App(TST1867) FM 4474 3055411 04/15/2015 PRI(TST5878) FM 4474 376T0098 01/26/2021 FM App(TST1867) FM 4474 3047636-LTR 06/24/2015 PRI(TST5878) FM 4474 376T0099 01/26/2021 FM App(TST1867) FM 4474 RR202913 11/19/2015 UL,LLC(QUA9625) QA Service confirmation 09/29/2020 FM App(TST1867) FM 4474 3053501 01/14/2016 UL,LLC(QUA9625) QA Florida BCIS Current NEMO ETC,LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 47:06/07/2021 Page 4 of 6 ONEMOletc. 4. PRODUCT DESCRIPTION: This Evaluation Report covers EverGuard'TPO Single-Ply Roof Membrane Systems installed in accordance with GAF published installation instructions and the Limitations/Conditions of Use herein. TABLE 1:EVALUATED MEMBRANES Material Standard Type Product Plant(s) Reference Type Grade EverGuard®TPO 45,60,80-mil ASTM D6878 N/A N/A IN,PA,TX,UT EverGuard Extreme'TPO 50,60,70,80-mil ASTM D6878 N/A N/A IN,TX, UT EverGuard°TPO Fleece-Back Roof Cover or Membrane(formerly EverGuard° 45,60,80-mil ASTM D6878 N/A N/A IN,PA,UT Cap Ply TPO FB Ultra) EverGuard Extreme®TPO Fleece- Back Membrane(formerly 50,60,70,80-mil ASTM D6878 N/A N/A IN EverGuard Extreme TPO FB Ultra) EverGuard®Freedom'"TPO HW 45,60-mil ASTM D6878 N/A N/A IN GAFGLAS®#75 Base Sheet ASTM D4601 II N/A CA-F,GA Tri-Ply®#75 Base Sheet ASTM D4601 II N/A CA-F,GA Base Sheets GAFGLAS®#80 Ultima'"^Base Sheet ASTM D4601 II N/A GA GAFGLAS®Stratavent®Nailable Venting Base Sheet ASTM D4897 II N/A CA-F,GA GAFGLAS®Ply 4 ASTM D2178 IV N/A CA-F,GA GAFGLAS®Ply 4 M ASTM D2178 IV N/A AL Ply Sheet GAFGLAS®FlexPly—6 ASTM D2178 VI N/A CA-F,GA GAFGLAS®FlexPly—6 M ASTM D2178 VI N/A AL Ruberoid°20 Smooth ASTM D6163 I S AR,CA-S,GA Ruberoid°HW 25 Smooth ASTM D6163 I S GA Ruberoid°30 Granule ASTM D6163 I G GA Base Ply or Ruberoid°HW Smooth ASTM D6164 I S GA Vapor Barrier Ruberoid®Mop Smooth ASTM D6164 I S CA-S,GA Membranes Ruberoid®Mop Smooth 1.5 ASTM D6164 I S CA-S,GA Ruberoid°Mop Plus Smooth ASTM D6164 II S CA-S Liberty'""SBS Self-Adhering Cap Sheet ASTM D6164 I G AR,GA,IN Ruberoid°Torch Granule ASTM D6222 I G GA, IN S. LIMITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 47:06/07/2021 Page 5 of 6 ONEMOletc. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: EverGuard° TPO Single-Ply Roof Membrane Systems shall be installed in accordance with GAF published installation instructions,subject to the Limitations/Conditions of Use noted herein. 7. BUILDING PERMIT • As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625: (414)248-6409, karen.buchmann@ul.com -THE 156-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard®TPO Single-Ply Roof Membrane Systems Revision 47:06/07/2021 Page 6 of 6 NNEMO I etc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 7-11 1c Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 12-14 1D Wood New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 14 1E Wood New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 15-16 1F Wood New,Reroof(Tear-Off)or Recover C-2 Plate-Bonded Roof Cover 17-18 1G Wood New,Reroof(Tear-Off)or Recover D-1 Insulated,Mechanically Attached Roof Cover 18-19 1H Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 19 11 Wood New,Reroof(Tear-Off)or Recover E-1 Non-Insulated,Mechanically Attached Roof Cover 19-20 L Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 20-23 2A Steel New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 24 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 24-38 2c Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Base and Cap Ply 38-40 2D Steel New or Reroof(Tear-Off) B-2 Mech.Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 41-46 2E Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 47-65 2F Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Base and Cap Ply 65-67 2c Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1A Thermal Barrier with Vapor Barrier,Mechanically Attached Insulation,Bonded Roof Cover 67-72 2H Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 73-75 21 Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-1 Insulated,Mechanically Attached Roof Cover 75-81 2t Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 81 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 82-99 3B Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Base and Cap Ply 100-101 3c Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 101 4A Lightweight concrete/concrete New or Reroof(Tear-Off) A-1 LWC to Deck,Bonded Insulation,Bonded Roof Cover 102-106 4B Lightweight concrete steel New or Reroof(Tear-Off) A-2 LWC to Deck,Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 107 4c Lightweight concrete/concrete New or Reroof(Tear-Off) A-2 LWC to Deck,Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 108 4D Lightweight concrete/steel or concrete New or Reroof(Tear Off) E-2 LWC to Deck,Mechanically Attached Base Sheet,Bonded Roof Cover 109-110 4E Lightweight concrete/steel New or Reroof(Tear Off) F LWC to Deck,Bonded Roof Cover 111-112 4F Lightweight concrete/concrete New or Reroof(Tear Off) F LWC to Deck,Bonded Roof Cover 112-13 4c Lightweight concrete/concrete New or Reroof(Tear Off) F Temp Roof/Vapor Barrier to Deck,LWC to Temp Roof/Vapor Barrier,Bonded Roof Cover 114 5A Cementious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 115-116 5B Cementious wood fiber New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 116 5c Cementious wood fiber New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 116 5D Cementious wood fiber New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 116 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 117-118 613 Existing gypsum Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 119 6c Existing gypsum Reroof(Tear-Off) B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 119-122 6D Existing gypsum Reroof(Tear-Off) C-1 Mechanically Attached Insulation,Bonded Roof Cover 122-123 6E Existing gypsum Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 123 6F Existing gypsum Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 123 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 124-152 7B Wood or Steel Recover C-2 Plate-Bonded Roof Cover 153-154 7c Steel Recover D-1 Insulated,Mechanically Attached Roof Cover 154-155 7D Various Recover F Non-Insulated,Bonded Roof Cover 156 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7"Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 1 of 156 *NEMO I etc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted,fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Drill-Tec#12 Fastener or Drill-Tec#14 Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only),Drill-Tec ASAP 3S,Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate,Drill-Tec#12 DP Fastener or Drill-Tec#14 HD Fastener with Drill-Tec 3"Flat Steel Plate, Drill-Tec#12 DPH Fastener with Drill-Tec 3"Recessed Steel Plate,Drill-Tec 3"ASAP Flat or Drill-Tec 3"ASAP Recessed. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: Drill-Tec#12 Fastener,Drill-Tec#14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only);Drill-Tec ASAP 3S;Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate;Drill-Tec Extra Heavy Duty ASAP Roofing Fastener- Insulation,Drill-Tec#12 DP Fastener,Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD Fastener with Drill-Tec 3"Flat Steel Plate,Drill-Tec#12 DPH Fastener with Drill-Tec 3"Recessed Steel Plate,Drill-Tec 3"ASAP Flat or Drill-Tec 3"ASAP Recessed. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: Drill-Tec#14 Fastener or Drill-Tec CD-10 with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only), Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate,Drill-Tec#14 HD Fastener with Drill-Tec 3"Flat Steel Plate or Drill-Tec 3"ASAP Flat(#14 only). Minimum 1- inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4 Minimum 200 psi,minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for,or installed below,rigid insulation board for System Types B-1,C-1,C-2,D-1 or D-2,whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck.The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues,such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(February 2020). 6 Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt: Full Coverage at 25-30lbs/square. If applying to concrete deck;deck shall be primed with ASTM D41 primer. ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): Continuous 2.5 to 3.5-inch ribbons,12-inch o.c. ➢ GAF LRF Adhesive M(LRF-M): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ GAF LRF Adhesive XF(LRF-XF): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.using OMG PaceCart,SpotShot or Canister delivery methods. ➢ Note:When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. ➢ Note:The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted.Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ Hot asphalt: MDP= -240.0 psf (Min.0.5-inch thick) ➢ GAF 2-Part: MDP= -117.5 psf (Min.1.0-inch thick) ➢ LRF-M: MDP= -232.5 psf (Min.0.5-inch thick EnergyGuard Polyiso Insulation,EnergyGuard Ultra Polyiso Insulation) ➢ LRF-XF or OB500: MDP= -292.5 psf (Min.0.5-inch thick EnergyGuard Polyiso Insulation,EnergyGuard Ultra Polyiso Insulation) ➢ OB500: MDP= -315.0 psf (Min.0.5-inch thick EnergyGuard RH or RN) ➢ LRF-XF or OB500: MDP= -487.5 psf (Min.0.5-inch thick EnergyGuard RA) 8 For adhered roof insulation and board-size: Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020). NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 2 of 156 ONEMOJetc. 9 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria.Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance.A qualified design professional shall review the data for comparison to the minimum requirements for the system.Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1,C-2,D-1 or D-2,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard maybe used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein).The separator component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWIC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications,unless otherwise noted,refer to the following. MEMBRANE/ADHESIVE COMBINATIONS MEMBRANE ADHESIVE REFERENCE APPLICATION RATE EverGuard TPO EverGuard TPO#1121 Bonding #1121 Contact(both sides) 0.8 to 1.0 gal/square/surface. For use over SECUROCK Gypsum-Fiber Roof Board,the Adhesive application rate changes to 1.2 to 1.67 gal/sq/surface To polyisocya nu rate or Structodek High Density Fiberboard Roof Insulation,Fiber Base HDl or EverGuard TPO EverGuard WB181 Bonding yyg181 Contact(both sides) Fiber Base HD6 at 0.63 gal/square and roof cover underside at 0.21 gal/square.To DensDeck Adhesive Prime or SECUROCK Gypsum-Fiber Roof Board at 0.63 to 0.75 gal/square and roof cover underside at 0.21 to 0.25 gal/square EverGuard TPO 6 Square Low VOC EverGuard TPO Bonding Adhesive(formerly EverGuard TPO 6-Square Contact(both sides) 0.46 gal/square/surface Low VOC TPO Bonding Adhesive) EverGuard TPO 3 Square Low VOC EverGuard TPO Bonding Adhesive TPO 3-Square Contact(both sides) 0.84 gal/square/surface EverGuard TPO EverGuard TPO Quick Spray TPO QSA Contact(both sides) Total application rate:-0.71 Ibs/sq(dry rate). Adhesive EverGuard TPO EverGuard TPO Quick Spray TPO QSA LV50 Contact(both sides) Total application rate:—0.84 lbs/sq(dry-rate). Adhesive LV 50 EverGuard TPO FastLayn TPO Adhesive FastLayn Wet lay(substrate) 0.4 gal/square EverGuard TPO Fleece- Hot asphalt Hot asphalt Wet lay(substrate) 25 Ibs/square Back Membrane NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 71h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 3 of 156 ONEMO I etc. MEMBRANE/ADHESIVE COMBINATIONS MEMBRANE ADHESIVE REFERENCE APPLICATION RATE EverGuard TPO Fleece- EverGuard WB181 Bonding Wg181 Wet lay(substrate) 0.83 to 1.0 gal/square Back Membrane Adhesive EverGuard TPO Fleece- 1-inch wide ribbons spaced as noted in tables herein. Note:The adhesive ribbons are located Back Membrane GAF LRF Adhesive M LRF-M Wet lay(substrate) directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. EverGuard TPO Fleece- 1-inch wide ribbons spaced as noted in tables herein. Note:The adhesive ribbons are located Back Membrane GAF LRF Adhesive O LRF-O Wet lay(substrate) directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. EverGuard TPO Fleece- GAF 2-Part Roofing Adhesive GAF 2-Part(spatter) Wet lay(substrate) "Spatter pattern"at 3.75 lbs/sq. Back Membrane EverGuard TPO Fleece- Back Membrane GAF LRF Adhesive XF LRF-XF(spatter) Wet lay(substrate) "Spatter pattern"at 3.0Ibs/sq. EverGuard TPO Fleece- OlyBond 500 Canister OB500(spatter) Wet lay(substrate) "Spatter pattern"at 0.32 gal/square(to insulation or coverboard) Back Membrane "Spatter pattern"at 0.83 gal/square(to asphaltic base ply membrane). 15A For single-ply membranes in System Type D-1 steel deck applications,the roof membrane shall be run with its length perpendicular to the steel deck flutes. 15B For System Type C-2(induction weld),care shall be taken to ensure that the plates do not line-up with membrane seams.This condition may preclude proper induction welding of the membrane to the plates. 15C The'Triposite Roofing System"noted herein consists of loose-laid GAFGLAS Stratavent Perforated Venting Base Sheet,followed by asphalt-applied one(1)or two(2)plies of Ruberoid 20 Smooth or three(3) plies of GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M,followed by asphalt-applied EverGuard TPO Fleece-Back Membrane with 1-5/8"heat welded side laps. 15D Unless otherwise noted,the"Hybrid Roofing System"noted herein consists of asphalt-applied Ruberoid 20 Smooth,Ruberoid Mop Smooth,Ruberoid Mop Smooth 1.5,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet or GAFGLAS#80 Ultima Base Sheet followed by asphalt-applied EverGuard TPO Fleece-Back Membrane. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations.The lesser of the MDP listings below vs.those in Table 3A or 38 applies. VAPOR BARRIER OPTIONS;STRUCTURAL CONCRETE DECK;FOLLOWED By ADHESIVE-APPUED INSULATION PER TABLE 3A OR 36 OPTION PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP # TYPE APPLICATION (PSF) One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet, C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Ply 4,GAFGLAS Ply 4 M,Tri-Ply Ply 4 Ply Sheet,GAFGLAS Hot asphalt applied Hot asphalt -360.0 FlexPly 6 or GAFGLAS FlexPly 6 M C-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied GAF 2-Part,12-inch o.c. -169.0 C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied GAF 2-Part,12-inch o.c. -180.0 C-VB-4. GAF SA Primer GAF SA Vapor Retarder Self-adhering GAF 2-Part,12-inch o.c. -202.5 C-VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering GAF 2-Part,12-inch o.c. -250.0 One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet, C-VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Ply 4,GAFGLAS Ply 4 M,Tri-Ply Ply 4 Ply Sheet,GAFGLAS Hot asphalt applied GAF 2-Part,12-inch o.c. -262.5 FlexPly 6 or GAFGLAS FlexPly 6 M C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part,12-inch o.c. -270.0 C-VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-M,12-inch o.c. -180.0 C-VB-9. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-M,12-inch o.c. -202.5 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FLS293-1146 Certificate of Authorization#32455 71^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 4 of 156 *NEMO I etc. VAPOR BARRIER OPTIONS;STRUCTURAL CONCRETE DECK;FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A OR 3B OPTION PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP # TYPE APPLICATION (PSF) One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet, C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Ply 4,GAFGLAS Ply 4 M,Tri-Ply Ply 4 Ply Sheet,GAFGLAS Hot asphalt applied LRF-M,12-inch o.c. -495.0 FlexPly 6 or GAFGLAS FlexPly 6 M C-VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied LRF-XF,12-inch o.c. -169.0 C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-XF,12-inch o.c. -180.0 C-VB-13. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-XF,12-inch o.c. -202.5 C-VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering LRF-XF,12-inch o.c. -250.0 One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet, C-VB-15. Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Ply 4,GAFGLAS Ply 4 M,Tri-Ply Ply 4 Ply Sheet,GAFGLAS Hot asphalt applied LRF-XF,12-inch o.c. -262.5 FlexPly 6 or GAFGLAS FlexPly 6 M C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied LRF-XF,12-inch o.c. -270.0 C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OB500,12-inch o.c. -165.0 C-VB-18. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OB500,12-inch o.c. -180.0 C-VB-19. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering OB500,12-inch o.c. -187.5 C-VB-20. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane OB500,12-inch o.c. -202.5 Adhesive at 1.5 gal/square C-VB-21. GAF SA Primer GAF SA Vapor Retarder Self-adhering OB500,12-inch o.c. -202.5 C-VB-22. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied OB500,12-inch o.c. -225.0 C-VB-23. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OB500,12-inch o.c. -232.5 One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet, C-VB-24. Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Ply 4,GAFGLAS Ply 4 M,Tri-Ply Ply 4 Ply Sheet,GAFGLAS Hot asphalt applied OB500,12-inch o.c. -352.5 FlexPly 6 or GAFGLAS FlexPly 6 M 17 Fire barriers of FireOutT"Fire Barrier Coating,VersaShield SoloT"Fire-Resistant Slip Sheet are optional in all assemblies when overlying components are mechanically fastened. 18 The following products are interchangeable within the scope of this Evaluation Report: ACCEPTABLE ALTERNATES Listed Product Alternate EverGuard TPO EverGuard Extreme TPO EverGuard TPO Fleece-Back Membrane EverGuard Extreme TPO Fleece-Back Membrane EnergyGuard Polyiso Insulation EnergyGuard NH Polyiso Insulation EnergyGuard Ultra Polyiso Insulation EnergyGuard NH Ultra Polyiso Insulation EnergyGuard HD Polyiso Insulation EnergyGuard NH HD Polyiso Insulation EnergyGuard HD Plus Polyiso Insulation EnergyGuard NH HD Plus Polyiso Insulation 19 For System Types B-1,B-2,C-1,C-2,D-1 or Type D-2,GAF SA Vapor Retarder may be installed atop the roof deck prior to installation of the insulation and roof cover. Refer to FM Loss Prevention Data Sheet 1-29 (February 2020)for design and installation limitations. 20 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 5 of 156 NNEMO I etc. TABLE IA: DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP System Deck No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) IPA (Notes 6,7,8) (Notes 6,7,8) EverGuard Freedom TPO: W 1 Min.19/32-inch plywood or Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layers base GAF 2-Part EverGuard Freedom TPO/self adhered -52.5 OSB;2 ft span EnergyGuard Ultra insulation,flat or tapered W 2 Min.19/32-inch plywood or Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layers base LRF-XF EverGuard Freedom TPO/self adhered -52.5 OSB;2 ft span EnergyGuard Ultra insulation,flat or tapered EverGuard TPO: W 3 Min.19/32-inch plywood or Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layers base GAF 2-Part EverGuard TPO/#1121,TPO 6-Square,TPO -52.5 OSB;2ftspan EnergyGuard Ultra insulation,flat or tapered 3-Square,WB181 Min.19/32-inch plywood or (Optional)Additional layers base W 4. OSB;2 ft span Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part insulation,flat or tapered GAF 2-Part EverGuard TPO/TPO QSA orTPO QSA LV50 -52.5 Min.19/32-inch plywood or Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO/#1121,TPO 6-Square,TPO W 5' LRF-XF LRF-XF OSB;2 ft span EnergyGuard Ultra insulation,flat or tapered 3-Square,WB181 -52.5 W 6 Min.19/32-inch plywood or Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layers base LRF-XF EverGuard TPO/TPO QSA or TPO QSA LV50 -52.5 OSB;2 ft span insulation,flat or tapered Min.15/32-inch plywood;2 Min.1-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO/#1121,TPO 6-Square,TPO W-7 OB500 ft EnergyGuard Ultra OB500 insulation,flatortapered 3-Square,WB181 -67.5 Min.15/32-inch plywood;2 (Optional)Additional layers base W 8. Min.1-inch EnergyGuard Polyiso Insulation OB500 insulation,flat or tapered OB500 EverGuard TPO/TPO QSA or TPO QSA LV50 -67.5 ft span Min.15/32-inch plywood;2 Min.1-inch EnergyGuard Polyiso Insulation, OB500,6- (Optional)Additional layers base OB500,6- EverGuard TPO/#1121,TPO 6-Square,TPO W 9' 75.0 ft span EnergyGuard Ultra inch o.c. insulation,flat or tapered inch o.c. 3-Square,WB181 W-10. Min.15/32-inch plywood;2 Min.1-inch EnergyGuard Polyiso Insulation OB500,6- (Optional)Additional layers base OB500,6- EverGuard TPO/TPO QSA or TPO QSA LV50 -75.0 ft span inch o.c. insulation,flat or tapered inch o.c. EverGuard TPO Fleece-Back Membrane: Min.19/32-inch plywood or Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO Fleece-Back Membrane/ W-11. OSB;2 ft span EnergyGuard Ultra GAF 2-Part insulation,flat or tapered GAF 2-Part WB181,GAF 2-Part(spatter),LRF-XF -52.5 (spatter)or OB500(spatter) Min.19/32-inch plywood or Min.1.S-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO Fleece-Back Membrane/ W 12. OSB;2 ft span EnergyGuard Ultra LRF-XF insulation,flat or tapered LRF-XF WB181 GAF Part(spatter),LRF-XF -52.5 (spatter) )or OBB500(spatter) Min.15/32-inch plywood;2 Min.1-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO Fleece-Back Membrane/ W-13. ft span EnergyGuard Ultra 06500 insulation,flat or tapered OB500 WB1tter81,GAF BPart(spatter),LRF-XF -67.5 (spatter)or OB500(spatter) Min.15/32-inch plywood;2 Min.1-inch EnergyGuard Polyiso Insulation, OB500,6- (Optional)Additional layers base OB500,6- EverGuard TPO Fleece-Back Membrane/ W-14. ft span EnergyGuard Ultra in o.c. insulation,flatortapered in o.c. WB181,GAF 2-Part(spatter),LRF-XF -75.0 (spatter)or OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 6 of 156 NNEMO I etc. TABLE 113: ... . . . SYSTEMTYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) Min.1-inch Min.0.5-inch Min. GAFGLAS#75 Base EverGuard TPO 8-inch o.c.at EnergyGuard Polyiso Structodek High One or two plies 15/32- Sheet,Tri-Ply#75 Base 32 ga.,1- Fleece-Back inch Sheet,GAFGLAS#80 min.4-inch laps Insulation, Density Fiberboard Ruberoid 20 Smooth, Membrane in hot 5/8-inch dia. and 8-inch o.c.in EnergyGuard Ultra Roof Insulation or Ruberoid Mop plywood Ultima Base Sheet, tin caps with hot hot asphalt or GAF 2- W-15. two,equally Polyiso Insulation or EnergyGuard Perlite Smooth,Ruberoid -45.0 or 1-inch GAFGLAS Stratavent 12 ga. asphalt asphalt Part(spatter), spaced, EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or wood Nailable Venting Base annular ring LRF-XF(spatter) staggered center Polyiso or min.1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus plank;2 ft Sheet,Ruberoid 20 shank nails 500 rows inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (s OB span Smooth (spatteerr)) or EnergyGuard RN (homogeneous) One or two plies Min.1-inch Ruberoid 20 Smooth, Min. GAFGLAS#75 Base EverGuard TPO 8-inch o.c.at EnergyGuard Polyiso Ruberoid Mop 15/32- Sheet,Tri-Ply#75 Base 32 ga.,1- Fleece-Back Ruberoid, , inch Sheet,GAFGLAS#80 5/8-inch dia. min.4-inch laps Insulation Min.0.25-inch Smooth Membrane in hot plywood Ultima Base Sheet, tin caps with and 8-inch o.c.in EnergyGuard Ultra hot DensDeck Prime or hot Mop Smooth 1.5 or asphalt or GAF 2- W-16. two,equally Polyiso Insulation or Ruberoid Mop Plus -45.0 or 1-inch GAFGLAS Stratavent 12 ga. asphalt SECUROCK Gypsum- asphalt Part(spatter), Smooth in hot asphalt wood Nailable Venting Base annular ring spaced, EnergyGuard RH staggered center Polyiso or min.1.5- Fiber Roof Board or Ruberoid HW 25 LRF-XF(spatter) plank;2 ft Sheet,Ruberoid 20 shank nails rows inch EnergyGuard RA Smooth or Ruberoid or OBS00 span Smooth or EnergyGuard RN HW Smooth,torch- (spatter) applied Min.1-inch Min.0.5-inch Min. EverGuard TPO 9-inch o.c.at EnergyGuard Polyiso Structodek High One or two plies 19/32- 32 ga.,1- Fleece-Back GAFGLAS#80 Ultima min.4-inch laps Insulation, Density Fiberboard Ruberoid 20 Smooth, inch 5/8-inch dia. Membrane in hot Base Sheet,GAFGLAS and 9-inch o.c.in EnergyGuard Ultra Roof Insulation or Ruberoid Mop plywood tin caps with hot hot asphaltat GAF 2- W-17. Stratavent Nailable two spaced, EnergyGuard RH,equally Polyiso Insulation or EnergyGuard Perlite Smooth Recover Board or Min. Mop Smooth 1.5 or ,Ruberoid -45.0 or 1-inch 12 ga. asphalt asphalt Part(spatter), Venting Base Sheet, wood annular ring LRF-XF(spatter) Ruberoid 20 Smooth staggered center Polyiso or min.1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus plank;2 ft shank nails rows inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (s OBpatteerr)) 500 span or EnergyGuard RN (homogeneous) (spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 7 of 156 NNEMO I etc. TABLE 113: ... . . . SYSTEMTYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) One or two plies Min.1-inch Ruberoid 20 Smooth, Min. EverGuard TPO 9-inch o.c.at EnergyGuard Polyiso Ruberoid Mop 19/32- 32 ga 5/8-inch dia..,1- Fleece-Back GAFGLAS#80 Ultima min.4-inch laps Insulation, Smooth,Ruberoid inch Min.0.25-inch Membrane in hot plywood Base Sheet,GAFGLAS and 9-inch o.c.in EnergyGuard Ultra Mop Smooth 1.5 or tin caps with hot DensDeck Prime or hot asphalt or GAF 2- W-18. or 1-inch 12 ga. asphalt SECUROCK Gypsum- asphalt Part(spatter),Stratavent Nailable two,equally Polyiso Insulation or Ruberoid Mop Plus -45.0 Venting Base Sheet, spaced, EnergyGuard RH Smooth in hot asphalt wood Ruberoid 20 Smooth shank nails annular ring staggered center Polyiso or min.1.5- Fiber Roof Board or Ruberoid HW 25 or OBS00 (spatter) plank;2 ft rows inch EnergyGuard RA Smooth or Ruberoid or B5 span or EnergyGuard RN HW Smooth,torch- (spatter) applied Min. GAFGLAS#75 Base Min.1-inch Min.0.5-inch EverGuard TPO 32 ga.,1- EnergyGuard Polyiso Structodek High One or two plies 15/32- Sheet,Tri-Ply#75 Base Fleece-Back 5/8-inch 6-inch o.c.at the Insulation, Density Fiberboard Ruberoid 20 Smooth, inch Sheet,GAFGLAS#80 Membrane in hot diameter tin 4-inch lap and 6- EnergyGuard Ultra Roof Insulation or Ruberoid Mop plywood Ultima Base Sheet, hot hot asphalt or GAF 2- W-19. or 1-inch GAFGLAS Stratavent asphalt asphalt Part(spatter),caps with 12 inch o.c.in two Polyiso Insulation or EnergyGuard Perlite Smooth,Ruberoid -52.5 ga.annular staggered center EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or wood Nailable Venting Base LRF-XF(spatter) ring shank rows Polyiso or min.1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus plank;2 ft Sheet,Ruberoid 20 nails inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt or OB500 span Smooth (spatter) or EnergyGuard RN (homogeneous) One or two plies Min.1-inch Ruberoid 20 Smooth, Min. GAFGLAS#75 Base EverGuard TPO 32 ga.,1- EnergyGuard Polyiso Ruberoid Mop 15/32- Sheet,Tri-Ply#75 Base Fleece-Back 5/8-inch 6-inch o.c.at the Insulation, Smooth,Ruberoid inch Sheet,GAFGLAS#80 Min.0.25-inch Membrane in hot diameter tin 4-inch lap and 6- EnergyGuard Ultra Mop Smooth 1.5 or plywood Ultima Base Sheet, hot DensDeck Prime or hot asphalt or GAF 2- W-20. caps with 12 inch o.c.in two Polyiso Insulation or Ruberoid Mop Plus -52.5 or 1-inch GAFGLAS Stratavent asphalt SECUROCK Gypsum- asphalt Part(spatter), ga.annular staggered center EnergyGuard RH Smooth in hot asphalt wood Nailable Venting Base ring shank rows Polyiso or min.1.5- Fiber Roof Board or Ruberoid HW 25 or OBSF-XFOO (spatter) plank;2 ft Sheet,Ruberoid 20 nails inch EnergyGuard RA Smooth or Ruberoid span Smooth or EnergyGuard RN HW Smooth,torch- (spatter) applied NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 8 of 156 NNEMO I etc. TABLE 113: ... . . . SYSTEMTYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) Min.1-inch Min.0.5-inch Min. GAFGLAS#75 Base EverGuard TPO 32 ga.,1- EnergyGuard Polyiso Structodek High One or two plies 19/32- Sheet,Tri-Ply#75 Base Fleece-Back 5/8-inch 8-inch o.c.at the Insulation, Density Fiberboard Ruberoid 20 Smooth, inch Sheet,GAFGLAS#80 Membrane in hot diameter tin 4-inch lap and 8- EnergyGuard Ultra Roof Insulation or Ruberoid Mop plywood Ultima Base Sheet, hot hot asphalt or GAF 2- W-21. caps with 12 inch o.c.in two Polyiso Insulation or EnergyGuard Perlite Smooth,Ruberoid -52.5 w inch GAFGLAS Stratavent asphalt asphalt Part(spatter), ga.annular staggered center EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or wood Nailable Venting Base LRF-XF(spatter) ring shank rows Polyiso or min.1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus plank;2 ft Sheet,Ruberoid 20 nails inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (s OB500 span Smooth (spatter) or EnergyGuard RN (homogeneous) One or two plies Min.1-inch Ruberoid 20 Smooth, Min. GAFGLAS#75 Base EverGuard TPO 32 ga.,1- EnergyGuard Polyiso Ruberoid Mop 19/32- Sheet,Tri-Ply#75 Base Fleece-Back 5/8-inch 8-inch o.c.at the Insulation, Smooth,Ruberoid inch Sheet,GAFGLAS#80 Min.0.25-inch Membrane in hot diameter tin 4-inch lap and 8- EnergyGuard Ultra plywood Ultima Base Sheet Mop Smooth 1.5 or, hot DensDeck Prime or hot asphalt or GAF 2- W-22. caps with 12 inch o.c.in two Polyiso Insulation or Ruberoid Mop Plus -52.5 or 1-inch GAFGLAS Stratavent asphalt SECUROCK Gypsum- asphalt Part(spatter), ga.annular staggered center EnergyGuard RH Smooth in hot asphalt wood Nailable Venting Base ring shank rows Polyiso or min.1.5- Fiber Roof Board or Ruberoid HW 25 LRF-XF(spatter) plank;2 ft Sheet,Ruberoid 20 nails inch EnergyGuard RA Smooth or Ruberoid or OB500 span Smooth or EnergyGuard RN HW Smooth,torch- (spatter) applied Min.1-inch Min.0.5-inch Min. EverGuard TPO EnergyGuard Polyiso Structodek High One or two plies 19/32- 32 ga.,1- Fleece-Back GAFGLAS#80 Ultima 8-inch o.c.at the Insulation, Density Fiberboard Ruberoid 20 Smooth, inch 5/8-inch dia. Membrane in hot Base Sheet,GAFGLAS 4-inch lap and 8- EnergyGuard Ultra Roof Insulation or Ruberoid Mop plywood tin caps with hot hot asphaltat GAF 2- W-23. or 1-inch 12 ga. asphalt asphalt Part(spatter), Stratavent Nailable inch o.c.in three Polyiso Insulation or EnergyGuard Perlite Smooth,Ruberoid -75.0* Venting Base Sheet, staggered center EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or wood Ruberoid 20 Smooth shank nails annular ring rows Polyiso or min.1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus or OB500 span (spatter) plank;2 ft inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (spatter) B5 or EnergyGuard RN (homogeneous) (spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMD ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 9 of 156 NNEMO I etc. TABLE 113: ... . . . SYSTEMTYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) One or two plies Min.1-inch Ruberoid 20 Smooth, Min. EverGuard TPO EnergyGuard Polyiso Ruberoid Mop 19/32- 32 ga.,1- Fleece-Back GAFGLAS#80 Ultima 8-inch o.c.at the Insulation, , inch 5/8-inch dia. Smooth Ruberoid Min.Deck inch Membrane hot Base Sheet,GAFGLAS 4-inch lap and 8- EnergyGuard Ultra Mop Smooth 1.5 or plywood hot Dens Prime or hot asphalt or GAF 2- tin caps with Ruberoid Mop Plus -75.0 W-24. Stratavent Nailable inch o.c.in three Polyiso Insulation or or 1-inch 12 ga. Part(spatter), asphalt SECUROCK Gypsum- asphalt Venting Base Sheet, staggered center EnergyGuard RH Smooth in hot asphalt wood Ruberoid 20 Smooth annular ring rows Polyiso or min.1.5- Fiber Roof Board or Ruberoid HW 25 or S OO span OB (spatter) plank;2 ft shank nails inch EnergyGuard RA Smooth or Ruberoid (s OB or EnergyGuard RN HW Smooth,torch- (spatter) applied GAFGLAS Stratavent Min. GAFGLAS#75 Base Perforated Venting EverGuard TPO 8-inch o.c.at Min.1-inch Base,loose laid, 15/32- Sheet,Tri-Ply#75 Base 32 ga.,1- Fleece-Back min.4-inch laps EnergyGuard Polyiso followed by one or inch Sheet,GAFGLAS#80 5/8-inch dia. Membrane in hot W-25. layer(s)base Smooth,Ruberoid and 8-inch o.c.in Insulation, (Optional)Additional two plies Ruberoid 20 plywood Ultima Base Sheet, tin caps with hot hot asphalt or GAF 2- -45.0 two,equally EnergyGuard Ultra or 1-inch GAFGLAS Stratavent 12 ga. asphalt asphalt Part(spatter), spaced, Polyiso Insulation or insulation Mop Smooth, wood Nailable Venting Base annular ring LRF-XF(spatter) staggered center EnergyGuard RH Ruberoid Mop Smooth plank;2 ft Sheet,Ruberoid 20 shank nails rows Polyiso 1.5 or Ruberoid Mop (s OB SOO span Smooth (spatter) Plus Smooth in hot asphalt GAFGLAS Stratavent Min. GAFGLAS#80 Ultima EverGuard TPO 9-inch o.c.at the Min.1-inch Base,loose laid, Perforated Venting 19/32- Base Sheet,GAFGLAS 32 ga.,1- Fleece-Back min.4-inch lap EnergyGuard Polyiso followed by one or inch Stratavent Eliminator 5/8-inch dia. Membrane in hot plywood Nailable Venting Base tin caps with and 9-inch o.c.in Insulation, (Optional)Additional two plies Ruberoid 20 hot hot asphalt or GAF 2- W-26. equally EnergyGuard Ultra layer(s)base Smooth Ruberoid two, , -45.0 or 1-inch Sheet,Ruberoid 20 12 ga. asphalt asphalt Part(spatter), spaced, Polyiso Insulation or insulation Mop Smooth, wood Smooth,Ruberoid Mop annular ring LRF-XF(spatter) staggered center EnergyGuard RH Ruberoid Mop Smooth plank;2 ft Smooth,Ruberoid Mop shank nails rows Polyiso 1.5 or Ruberoid Mop (s OBpatteerr)) SOO span Smooth 1.5 Plus Smooth in hot (spatter) asphalt NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 10 of 156 NNEMO I etc. TABLE 113: ... . . . SYSTEIVITYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) GAFGLAS Stratavent Min. GAFGLAS#75 Base Perforated Venting EverGuard TPO 6-inch o.c.at Min.1-inch Base,loose laid, 15/32- Sheet,Tri-Ply#75 Base 32 ga.,1- Fleece-Back min.4-inch laps EnergyGuard Polyiso followed by one or inch Sheet,GAFGLAS#80 5/8-inch dia. Membrane in hot and 6-inch o.c.in Insulation, (Optional)Additional two plies Ruberoid 20 plywood Ultima Base Sheet, tin caps with hot hot asphalt or GAF 2- W-27. equally EnergyGuard Ultra layer(s)base Smooth Ruberoid two, , -52.5 or 1-inch GAFGLAS Stratavent 11 ga. asphalt asphalt Part(spatter), spaced, Polyiso Insulation or insulation Mop Smooth, wood Nailable Venting Base annular ring LRF-XF(spatter) staggered center EnergyGuard RH Ruberoid Mop Smooth plank;2 ft Sheet,Ruberoid 20 shank nails rows Polyiso 1.5 or Ruberoid Mop (s OB SOO span Smooth (spatter) Plus Smooth in hot asphalt GAFGLAS Stratavent Min. GAFGLAS#75 Base Perforated Venting EverGuard TPO 32 ga.,1- Min.1-inch Base,loose laid, 19/32- Sheet,Tri-Ply#75 Base Fleece-Back 5/8-inch 8-inch o.c.at the EnergyGuard Polyiso followed by one or inch Sheet,GAFGLAS#80 Membrane in hot diameter tin 4-inch lap and 8- Insulation, (Optional)Additional two plies Ruberoid 20 plywood Ultima Base Sheet, hot hot asphalt or GAF 2- W-28. caps with 12 inch o.c.in two EnergyGuard Ultra layer(s)base Smooth,Ruberoid -52.5 or 1-inch GAFGLAS Stratavent asphalt asphalt Part(spatter), ga.annular staggered center Polyiso Insulation or insulation Mop Smooth, wood Nailable Venting Base LRF-XF(spatter) ring shank rows EnergyGuard RH Ruberoid Mop Smooth plank;2 ft Sheet,Ruberoid 20 nails Polyiso 1.5 or Ruberoid Mop or OBS00 span Smooth (spatter) Plus Smooth in hot asphalt GAFGLAS Stratavent Perforated Venting Min. EverGuard TPO Min.1-inch Base,loose laid, 19/32- 32 ga.,1- Fleece-Back 5/8-inch dia. GAFGLAS#80 Ultima 8-inch o.c.at the EnergyGuard Polyiso followed by one or inch Membrane in hot Base Sheet,GAFGLAS 4-inch lap and 8- Insulation, (Optional)Additional two plies Ruberoid 20 plywood tin caps with hot hot asphalt or GAF 2- W-29. Stratavent Nailable inch o.c.in three EnergyGuard Ultra layer(s)base Smooth,Ruberoid Venting Base Sheet, staggered center Polyiso Insulation or insulation Mop Smooth, -75.0* or 1-inch 12 ga. asphalt asphalt Part(spatter), wood annular ring LRF-XF(spatter) plank;2 ft Ruberoid 20 Smooth shank nails rows EnergyGuard RH Ruberoid Mop Smooth or OBS00 Polyiso 1.5 or Ruberoid Mop span Plus Smooth in hot (spatter) asphalt NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 11 of 156 NNEMO I etc. TABLE 1c:WOOD DECKS—NEW CONSTRUCTION.REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) Min.1-inch Min.0.5-inch Min. GAFGLAS#75 Base EnergyGuard Polyiso Structodek High Density EverGuard TPO 15/32- Sheet,Tri-Ply#75 Base 16-inch o.c.at the One or two plies Fleece-Back Fiberboard Roof inch Sheet,GAFGLAS#80 min.4-inch lap Insulation, Ruberoid 20 Smooth, Membrane in EnergyGuard Ultra Insulation or plywood Ultima Base Sheet, Note 2(#14 and 16-inch o.c.in hot hot Ruberoid Mop Smooth, hot asphalt or W-30. or 1-inch GAFGLAS Stratavent ONLY) two,equally Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Ruberoid Mop Smooth GAF 2-Part -52.5 wood Nailable Venting Base spaced,staggered EnergyGuard RH Recover Board or Min. 1.5 or Ruberoid Mop Plus (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 center rows Polyiso or min.1.5- 0.75-inch EnergyGuard Smooth in hot asphalt XF(spatter)or span Smooth inch EnergyGuard RA Perlite Roof Insulation OB500(spatter) or EnergyGuard RN I (homogeneous) Min. GAFGLAS#75 Base Min.1-inch One or two plies EverGuard TPO EnergyGuard Polyiso Ruberoid 20 Smooth, 15/32- Sheet,Tri-Ply#75 Base 16-inch o.c.at the Fleece-Back Insulation, Ruberoid Mop Smooth, EnergyGuard Ultra Ruberoid Mop Smooth inch Sheet,GAFGLAS#80 min.4-inch lap Min.0.25-inch Membrane in plywood Ultima Base Sheet, Note 2(#14 and 16-inch o.c.in hot DensDeck Prime or hot hot asphalt or W-31. or 1-inch GAFGLAS Stratavent ONLY) two,equally Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt Smooth in hot asphalt or 1.5 or Ruberoid Mop Plus GAF 2-Part -52.5 wood Nailable Venting Base spaced,staggered EnergyGuard RH Fiber Roof Board (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 center rows Polyiso or min.1.5- Ruberoid HW 25 Smooth XF(spatter)or span Smooth inch EnergyGuard RA or Ruberoid HW Smooth, OB500(spatter) or EnergyGuard RN torch-applied Min. GAFGLAS#75 Base Min.1-inch Min.0.5-inch EverGuard TPO EnergyGuard Polyiso Structodek High Density 15/32- Sheet,Tri-Ply#75 Base 12-inch o.c.at the Insulation, Fiberboard Roof One or two plies Fleece-Back EnergyGuard Ultra Insulation or inch Sheet,GAFGLAS#80 min.4-inch lap Ruberoid 20 Smooth, Membrane in plywood Ultima Base Sheet, Note 2(#14 and 12-inch o.c.in Polyiso Insulation or EnergyGuard Perlite hot hot Ruberoid Mop Smooth, hot asphalt or W-32. -60.0 or 1-inch GAFGLAS Stratavent ONLY) two,equally EnergyGuard RH asphalt asphalt Ruberoid Mop Smooth GAF 2-Part Recover Board or Min. wood Nailable Venting Base spaced,staggered 1.5 or Ruberoid Mop Plus (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 center rows Polyiso or min.1.5- 0.75-inch EnergyGuard Smooth in hot asphalt XF(spatter)or span Smooth inch EnergyGuard RA Perlite Roof Insulation OB500(spatter) or EnergyGuard RN (homogeneous) Min. GAFGLAS#75 Base Min.1-inch One or two plies EverGuard TPO 15/32- Sheet,Tri-Ply#75 Base 12-inch o.c.at the EnergyGuard Polyiso Ruberoid 20 Smooth, Fleece-Back inch Sheet,GAFGLAS#80 min.4-inch lap Insulation, Min.0.25-inch Ruberoid Mop Smooth, Membrane in plywood Ultima Base Sheet, Note 2(#14 and 12-inch o.c.in EnergyGuard Ultra Ruberoid Mop Smooth hot DensDeck Prime or hot hot asphalt or W-33. or 1-inch GAFGLAS Stratavent ONLY) two,equally Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt 1.5 or Ruberoid Mop Plus GAF 2-Part -60.0 wood Nailable Venting Base spaced,staggered EnergyGuard RH Fiber Roof Board Smooth in hot asphalt or (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 center rows Polyiso r min.1.5- Ruberoid 25 Smooth XF(spatter)or span Smooth inch EnergyGuard RA to Ruberoid d HW Smooth, OB500(spatter) or EnergyGuard RN torch-applied NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 12 of 156 NNEMO I etc. TABLE 1c:WOOD DECKS—NEW CONSTRUCTION.REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) Min.1-inch Min.0.5-inch Min. GAFGLAS#75 Base EverGuard TPO EnergyGuard Polyiso Structodek High Density 15/32- Sheet,Tri-Ply#75 Base One or two plies Fleece-Back 8-inch o.c.at the Insulation, Fiberboard Roof inch Sheet,GAFGLAS#80 Ruberoid 20 Smooth, Membrane in 4-inch lap and 8- EnergyGuard Ultra Insulation or plywood Ultima Base Sheet, Note 2(#14 hot hot Ruberoid Mop Smooth, hot asphalt or or 1-inch GAFGLAS Stratavent ONLY) asphalt asphalt Ruberoid Mop Smooth GAF 2-Part W-34. inch o.c.in three Polyiso Insulation or EnergyGuard Perlite -75.0* staggered center EnergyGuard RH Recover Board or Min. wood Nailable Venting Base rows Polyiso or min.1.5- 0.75-inch EnergyGuard 1.5 or Ruberoid Mop Plus (spatter), plank;2 ft Sheet,Ruberoid 20 inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt XF(spatterr))o span Smooth OB500(spatter) or EnergyGuard RN I (homogeneous) Min. GAFGLAS#75 Base Min.1-inch One or two plies EverGuard TPO EnergyGuard Polyiso Ruberoid 20 Smooth, 15/32- Sheet,Tri-Ply#75 Base Fleece-Back inch Sheet,GAFGLAS#80 8-inch o.c.at the Insulation, Min.0.25-inch Membrane in Ruberoid Mop Smooth, 4-inch lap and 8- EnergyGuard Ultra Ruberoid Mop Smooth plywood Ultima Base Sheet, Note 2(#14 hot DensDeck Prime or hot hot asphalt or W-35. or 1-inch GAFGLAS Stratavent ONLY) inch o.c.in three Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt 1.5 or Ruberoid Mop Plus GAF 2-Part 82.5 staggered center EnergyGuard RH Smooth in hot asphalt or wood Nailable Venting Base rows Polyiso or min.1.5- Fiber Roof Board Ruberoid HW 25 Smooth (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 inch EnergyGuard RA or Ruberoid HW Smooth, XF(spatter)or span Smooth or EnergyGuard RN torch-applied OB500(spatter) GAFGLAS Stratavent Min. GAFGLAS#75 Base EverGuard TPO Min.1-inch Perforated Venting Base, 15/32- Sheet,Tri-Ply#75 Base 16-inch o.c.at the Fleece-Back inch Sheet,GAFGLAS#80 min.4-inch lap EnergyGuard Polyiso loose laid,followed by Membrane in Insulation, one or two plies plywood Ultima Base Sheet, Note 2(#14 and 16-inch o.c.in EnergyGuard Ultra Ruberoi 20 Smoot hot (Optional)Additional hot hot asphalt or W-36. d h, -52.5 or 1-inch GAFGLAS Stratavent ONLY) two,equally asphalt layer(s)base insulation asphalt GAF 2-Part wood Nailable Venting Base spaced,staggered Polyiso Insulation or Ruberoid Mop Smooth, (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 center rows EnergyGuard RH Ruberoid Mop Smooth XF(spatter)or span Smooth Polyiso 1.5 or Ruberoid Mop Plus OB500(spatter) Smooth in hot asphalt Min. GAFGLAS#75 Base GAFGLAS Stratavent EverGuard TPO Min.1-inch Perforated Venting Base, 15/32- Sheet,Tri-Ply#75 Base 12-inch o.c.at the Fleece-Back inch Sheet,GAFGLAS#80 min.4-inch lap EnergyGuard Polyiso loose laid,followed by Membrane in Insulation, one or two plies plywood Ultima Base Sheet, Note 2(#14 and 12-inch o.c.in hot (Optional)Additional hot hot asphalt or W-37. EnergyGuard Ultra Ruberoid 20 Smooth, -60.0 or 1-inch GAFGLAS Stratavent ONLY) two,equally asphalt layer(s)base insulation asphalt GAF Part wood Nailable Venting Base spaced,staggered Polyiso Insulation or Ruberoid Mop Smooth, (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 center rows EnergyGuard RH Ruberoid Mop Smooth XF(spatter)or span Smooth Polyiso 1.5 or Ruberoid Mop Plus OB500(spatter) Smooth in hot asphalt NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 13 of 156 NNEMO I etc. TABLE 1c:WOOD DECKS-NEW CONSTRUCTION.REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type sf (Note 11) YP (Notes Base Cap (p ) 6,7,8) 6,7,8) Min. GAFGLAS#75 Base GAFGLAS Stratavent EverGuard TPO 15/32- Sheet,Tri-Ply#75 Base Min.1-inch Perforated Venting Base, Fleece-Back inch Sheet,GAFGLAS#80 8-inch o.c.at the EnergyGuard Polyiso loose laid,followed by Membrane in 4-inch lap and 8- Insulation, one or two plies hot asphalt or plywood Ultima Base Sheet, Note 2(#14 hot (Optional)Additional hot W-38. inch o.c.in three EnergyGuard Ultra Ruberoid 20 Smooth, -82.5* w o inch GAFGLAS emit gas ONLY) asphalt layer(s)base insulation asphalt GAF tePart staggered center Polyiso Insulation or Ruberoid Mop Smooth, wood Sheet, Venting Base rows EnergyGuard RH Ruberoid Mop Smooth (spatter),LRF- plank;2 ft Sheet,Ruberoid 20 XF(spatter)OB500(spatttor eo Polyiso 1.5 or Ruberoid Mop Plus span Smooth r) Smooth in hot asphalt TABLE ID:WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Fasten(Note 11) Attach Type Attach Roof Cover(Note 15) (Psf) (Notes 6,7,8) EverGuard FreedomTPO Applications: W-39. Min.15/32-inch plywood or Min 2-inch EnergyGuard Polyiso Note 2(#14 1 per Min.0.25-inch SECUROCK GAF 2-Part,LRF-M, EverGuard Freedom TPO/self adhered -52.5 1-inch wood plank;2 ft span Insulation,EnergyGuard RH Fastener only) 2.0 ft' Gypsum-Fiber Roof Board LRF-XF or OB500 EverGuard TPO Applications: Min.15/32-inch plywood or Min 2-inch EnergyGuard Polyiso Note 2(#14 1 per Min.0.25-inch SECUROCK GAF 2-Part,LRF-M, EverGuard TPO/#1121,TPO 6-Square,TPO W-40. 1-inch wood plank;2 ft span Insulation,EnergyGuard RH Fastener only) 2.0 ft' Gypsum-Fiber Roof Board LRF-XF or OB500 3-Square,TPO QSA or TPO QSA LV50 -52.5 W 41 Min.19/32-inch plywood or Min.3-inch EnergyGuard Ultra Note 2 1 per Min.0.25-inch SECUROCK LRF-XF 4-inch o EverGuard TPO/TPO QSA or TPO QSA 82 5 1-inch wood plank;2 ft span 1.0 ft , .c.Gypsum-Fiber Roof Board LV50 W 42 Min.19/32-inch plywood or Min.3-inch EnergyGuard Polyiso Note 2 1 per Min.0.25-inch SECUROCK OB500,4-inch o.c. EverGuard TPO/TPO QSA or TPO QSA 82 5 1-inch wood plank;2 ft span Insulation or EnergyGuard Ultra 1.0 ft2 Gypsum-Fiber Roof Board LV50 W 43 Min.19/32-inch plywood or Min.3-inch EnergyGuard Ultra Note 2 1 per Min.0.25-inch SECUROCK LRF-XF,4-inch o.c. EverGuard TPO/#1121 -120.0 1-inch wood plank;2 ft span 1.0 ft2 Gypsum-Fiber Roof Board W 44 Min.19/32-inch plywood or Min.3-inch EnergyGuard Polyiso Note 2 1 per Min.0.25-inch SECUROCK OBSOO,4-inch o.c. EverGuard TPO/#1121 -120.0 1-inch wood plank;2 ft span Insulation or EnergyGuard Ultra 1.0 ft2 Gypsum-Fiber Roof Board EverGuard TPO Fleece-Back Membrane Applications: Min.15/32-inch plywood or Min 2-inch EnergyGuard Polyiso Note 2(#14 1 per Min.0.25-inch SECUROCK GAF 2-Part,LRF-M, EverGuard TPO Fleece-Back Membrane/ W 45. 1-inch wood plank;2 ft span Insulation,EnergyGuard RH Fastener only) 2.0 ft2 Gypsum-Fiber Roof Board LRF-XF or OB500 GAF 2-Part(spatter),LRF-XF(spatter)or -52.5 OB500(spatter) W 46 Min.19/32-inch plywood or Min.3-inch EnergyGuard Ultra Note 2 1 per Min.0.25-inch SECUROCK LRF-XF,4-inch o.c. EverGuard TPO Fleece-Back Membrane/ -120.0 1-inch wood plank;2 ft span 1.0 ft Gypsum-Fiber Roof Board OB500(spatter) W 47 Min.19/32-inch plywood or Min.3-inch EnergyGuard Polyiso Note 2 1 per Min.0.25-inch SECUROCK OB500,4-inch o.c. EverGuard TPO Fleece-Back Membrane/ -120.0 1-inch wood plank;2 ft span Insulation or EnergyGuard Ultra 1.0 ft' Gypsum-Fiber Roof Board OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 14 of 156 NNEMOjetc. TABLE IE: DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER BONDEDSYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck(Note 1) Base Insulation Top Insulation Layer Roof Cover(Note 15) MDP No. Layer(Note 13) Type Fasteners(Note 11) Attach Base Cap (psf) EverGuard TPO: Min.15/32-inch plywood (Optional)One Min.1.5-inch 1 per EverGuard TPO/#1121,TPO 3- W-48. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 2.7 ft2 None Square,TPO QSA or TPO QSA LV50 -37.5* ft span any combination Insulation Min.15/32-inch plywood (Optional)One Min.2-inch TPO 3,121 -EverGuard TPO/#1 W-49. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 2 7 1 per erft' None Square,TPO QSA 1 21 QSA LV50 -45.0* ft span any combination Insulation Min.15/32-inch plywood (Optional)One Min.0.25-inch W-50. or 1-inch wood plank;2 or more layers, DensDeck Prime or Note 2(#14 Fastener only) 1 per None EverGuard TPO/#1121,TPO 3- -45.0* ft span any combination SECUROCK Gypsum- 2.7 ft2 Square,TPO QSA or TPO QSA LV50 Fiber Roof Board Min.15/32-inch plywood (Optional)One Min.1.5-inch 1 per EverGuard TPO/#1121,TPO 3- W-51. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 2.0 ft2 None Square,TPO QSA or TPO QSA LV50 -45.0* ft span any combination Insulation APA rated,19/32 CAT, (Optional)One Min.1-inch EverGuard TPO/#1121,WB181, W-52. 0.578 in.,Exposure 1 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 2 per None TPO 3-Square,TPO QSA or TPO -45.0* OSB;2 ft span any combination Insulation QSA LV50 Min.15/32-inch plywood (Optional)One Min.1.5-inch 1 per EverGuard TPO/#1121,TPO 3- W-53. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2 1 8 ft' None Square,TPO QSA or TPO QSA LV50 -52.5 ft span any combination Insulation Min.15/32-inch plywood (Optional)One Min.0.25-inch 1 per EverGuard TPO/#1121,TPO 3- W-54. or 1-inch wood plank;2 or more layers, DensDeck Prime Note 2 1.8 ft' None Square,TPO QSA or TPO QSA LV50 -52.5 ft span any combination Min.15/32-inch plywood (Optional)One Min.0.25-inch 1 per EverGuard TPO/#1121,TPO 3- W-55. or 1-inch wood plank;2 or more layers, SECUROCK Gypsum- Note 2 1.8 ft2 None Square,TPO QSA or TPO QSA LV50 -60.0 ft span any combination Fiber Roof Board Min.15/32-inch plywood (Optional)One Min.1.5-inch 1 per EverGuard TPO/#1121,TPO 3- W-56. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2 1.6 ft2 None Square,TPO QSA or TPO QSA LV50 -60.0 ft span any combination Insulation Min.15/32-inch plywood (Optional)One Min.1.5-inch 1 per EverGuard TPO/or TPO L W-57. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 1.3 ft2 None Square,TPO QSA 1 21,TPO QSA - -60.0 ft span any combination Insulation EverGuard TPO Fleece-Back Membrane: Min.15/32-inch plywood (Optional)One Min.1.5-inch 1 per EverGuard TPO Fleece-Back W-58. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 2.7 er None Membrane/GAF 2-Part(spatter), -37.5* ft span any combination Insulation LRF-XF(spatter)or OB500(spatter) Min.15/32-inch plywood (Optional)One Min.2-inch EverGuard TPO Fleece-Back 2 W-59. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) .per7 ft' None Membrane/GAF 2-Part(spatter), -45.0* ft span any combination Insulation LRF-XF(spatter)or OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 71^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 15 of 156 NNEMO I etc. TABLE IE: DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER BONDEDSYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover(Note 15) MOP No. Deck(Note 1) Layer(Note 13) Type Fasteners(Note 11) Attach Base Cap (psf) Min.15/32-inch plywood (Optional)One Min.0.25-inch EverGuard TPO Fleece-Back W-60. or 1-inch wood plank;2 or more layers, DensDeck Prime or Note 2(#14 Fastener only) 1 per None Membrane/GAF 2-Part(spatter), -45.0* ft span any combination SECUROCK Gypsum- 2.7 ft2 LRF-XF(spatter)or OB500(spatter) Fiber Roof Board Min.15/32-inch plywood (Optional)One Min.1.5-inch EverGuard TPO Fleece-Back W-61. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 1 per None Membrane/GAF 2-Part(Spatter), -45.0* ft span any combination Insulation 2.0 ft2 LRF-XF(spatter)or OB500(spatter) APA rated,19/32 CAT, (Optional)One Min.1-inch EverGuard TPO Fleece-Back W-62. 0.578 in.,Exposure 1 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 1 per None Membrane/GAF 2-Part(spatter), -45.0* OSB;2 ft span any combination Insulation 2.0 ft2 LRF-XF(spatter)or OB500(spatter) Min.15/32-inch plywood (Optional)One Min.1.5-inch 1 er EverGuard TPO Fleece-Back W-63. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2 1 8 ft, None Membrane/GAF 2-Part(spatter), -52.5 ft span any combination Insulation LRF-XF(spatter)or OB500(spatter) Min.15/32-inch plywood (Optional)One Min.0.25-inch 1 per EverGuard TPO Fleece-Back W-64. or 1-inch wood plank;2 or more layers, DensDeck Prime Note 2 1.8 ft' None Membrane/GAF 2-Part(spatter), -52.5 ft span any combination LRF-XF(spatter)or OB500(spatter) Min.15/32-inch plywood (Optional)One Min.0.25-inch 1 per EverGuard TPO Fleece-Back W-65. or 1-inch wood plank;2 or more layers, SECUROCK Gypsum- Note 2 1.8 ft' None Membrane/GAF 2-Part(spatter), -60.0 ft span any combination Fiber Roof Board LRF-XF(spatter)or OB500(spatter) Min.15/32-inch plywood (Optional)One Min.1.5-inch EverGuard TPO Fleece-Back W-66. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2 1 per None Membrane/GAF 2-Part(spatter), -60.0 ft span any combination Insulation 1.6 ft2 LRF-XF(spatter)or OB500(spatter) Drill-Tec#14 with Drill-Tec 3 in. One or two plies Ruberoid 20 Smooth, Min.19 32-inch wood Ruberoid Mop Smooth,Ruberoid Mop EverGuard TPO Fleece-Back / plywood (Optional)One Min.0.25-inch Ribbed Galvalume Plate(Flat)or 1 per Smooth 1.5 or Ruberoid Mop Plus Membrane in hot asphalt or GAF 2- W-67. or 1-inch wood plank;2 or more layers, SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plate or Drill- 1 8 ft� Smooth in hot asphalt or One or two Part(spatter),LRF-XF(spatter)or -60.0 ft span any combination Fiber Roof Board Tec#14 HD Fastener with Drill-Tec 3"Flat Steel Plate plies Ruberoid HW 25 Smooth or OB500(spatter) Ruberoid HW Smooth,torch-applied Min.15/32-inch plywood (Optional)One Min.1.5-inch EverGuard TPO Fleece-Back W-68. or 1-inch wood plank;2 or more layers, EnergyGuard Polyiso Note 2(#14 Fastener only) 1 per 3 ft2 None Membrane/GAF 2-Part(spatter), -60.0 ft span any combination Insulation 1. LRF-XF(spatter)or OB500(spatter) Min.19/32-inch plywood (Optional)One Min.0.25-inch rAccuTrac ec#12 with Drill-Tec 1 per EverGuard TPO Fleece-Back W-69. or 1-inch wood plank;2 or more layers, SECUROCK Gypsum- Flat Plate 1.3 ft' None Membrane in hot asphalt 82.5 ft span any combination Fiber Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 16 of 156 NNEMO etc. TABLE 1F: DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: ROOF System Deck Insulation Attachment MDP No. (Note 1) (Note 13) Fasteners(Note 11) Spacing Roof Cover(Note 156) (Psf) One or more layers,any Drill-Tec XHD Fastener and Drill-Tec 1 per 2.7 ftz(12 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond Min.19/32-inch OSB;2 ft combination, RhinoBond TPO XHD Plates or Drill- Fasteners are 8-,24-and 40-inches from TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-70. preliminarily attached Tread Safe Plates with RhinoBond Portable -30.0 span Tec RhinoBond TPO XHD Tread Safe the board's long edge and 12-,36-,60-and (Tread Safe=min.2-inch Plates 84-inches from the board's short edge. Bonding Tool,per manufacturer's published thick insulation) instructions. Min.15/32-inch One or more layers,any Drill-Tec#14(min.1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood,min.19/32-inch combination, embedment into joist)and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD 12-inch o.c.along wood supports,96-inch W 71. OSB or plank atoopp 1-inch wood nominal 2 x 8 Preliminarily attached RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -30.0 inch lumber supports (Tread Safe=min.2-inch Tec RhinoBond TPO XHD Tread SafeBonding Tool,per manufacturer's published spaced max.96-inc o.c. thick insulation) Plates through to wood supports instructions. Min.15inch Drill-Tec#14(min.1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywoodd,,min.19/32-inch One or more layers,any O or 1-inch wood combination(Tread Safe 24-inch o.c.along wood supports,48-inch embedment into joist)and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-72. plank k atop nominal 2 x 8 =min.2-inch thick RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -37.5 inch lumber supports insulation) Tec RhinoBond TPO XHD Tread SafeBonding Tool,per manufacturer's published spaced max.48-inch o.c. Plates through to wood supports instructions. One or more layers,any Drill-Tec XHD Fastener and Drill-Tec 1 per 2.0 ftz 116 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond Min.19/32-inch OSB;2 ft combination, RhinoBond TPO XHD Plates or Drill- Fasteners are 12-and 36-inches from the TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-73. preliminarily attached board's long edge and 6-,18-,30-,42-,54-, Tread Safe Plates with RhinoBond Portable -45.0 span (Tread Safe=min.2-inch Tec RhinoBond TPO XHD Tread Safe 66-,78-and 90-inches from the board's Bonding Tool,per manufacturer's published thick insulation) Plates short edge. instructions. Drill-Tec#14 Fastener and Drill-Tec 1 per 2.7 ftz(12 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond Min.15/32-inch plywood One or more layers,any RhinoBond TPO XHD Plates or Drill- Fasteners are 6-,24-and 42-inches from TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-74. or 1-inch wood plank;2 ft combination(Tread Safe Tread Safe Plates with RhinoBond Portable -52.5 Tec RhinoBond TPO XHD Tread Safe the board's long edge and 12-,36-,60-and span =min.2-inch) Plates 84-inches from the board's short edge. Bonding Tool,per manufacturer's published instructions. Min.15/32-inch Drill-Tec#14(min.1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood,min.19/32-inch (Optional)One or more embedment into joist)and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 75 OSB or 1-inch wood layers,any combination RhinoBond TPO XHD Plates or Drill- 36-inch o.c.along wood supports,24-inch Tread Safe Plates with RhinoBond Portable -52.5 plank over nominal No.2 (Tread Safe=min.2-inch Tec RhinoBond TPO XHD Tread Safe O.C. Bonding Tool,per manufacturer's published wood trusses spaced thick insulation) Plates through to wood supports instructions. max.24-inch o.c. Min.15/32-inch Drill-Tec#14(min.1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood,min.19/32-inch (Optional)One or more embedment into joist)and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD OSB or 1-inch wood layers,any combination 24-inch o.c.along wood supports,24-inch W-76. RhinoBond TPO XHD Plates or Drill- Tread Safe Plates with RhinoBond Portable -75.0 plank over nominal No.2 (Tread Safe=min.2-inch Tec RhinoBond TPO XHD Tread Safe O.C. Bonding Tool,per manufacturer's published wood trusses spaced thick insulation) Plates through to wood supports instructions. max.24-inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NE VIO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 17 of 156 NNEMO I etc. TABLE 1F:WOOD DECKS PLATE-BONDEDSYSTEM TYPE C-2: ROOF System Deck Insulation Attachment MDP No. (Note 1) (Note 13) Fasteners(Note 11) Spacing Roof Cover(Note 156) (Psf) Min.15/32-inch Drill-Tec#14(min.1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood,min.19/32-inch (Optional)One or more embedment into joist)and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 77 OSB or 1-inch wood layers,any combination RhinoBond TPO XHD Plates or Drill- 18-inch o.c.along wood supports,24-inch Tread Safe Plates with RhinoBond Portable -82.5 plank over nominal No.2 (Tread Safe=min.2-inch Tec RhinoBond TPO XHD Tread Safe O.C. Bonding Tool,per manufacturer's published wood trusses spaced thick insulation) Plates through to wood supports instructions. max.24-inch o.c. Min.19/32-inch Drill-Tec#14(min.1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood,min.19/32-inch (Optional)One or more embedment into joist)and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 78 OSB or 1-inch wood layers,any combination RhinoBond TPO XHD Plates or Drill- 9-inch o.c.along wood supports,24-inch Tread Safe Plates with RhinoBond Portable -90.0 plank over nominal No.2 (Tread Safe=min.2-inch Tec RhinoBond TPO XHD Tread Safe O.C. Bonding Tool,per manufacturer's published wood trusses spaced thick insulation) Plates through to wood supports instructions. max.24-inch o.c. Min.19/32-inch Drill-Tec#14(min.1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood,min.19/32-inch One or more layers,any embedment into joist)and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD OSB or 1-inch wood combination,min.1-inch 9-inch o.c.along wood supports,24-inch W 79. plank over nominal No.2 (Tread Safe=min.2-inch RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -105.0 wood trusses spaced thick insulation) Tec RhinoBond TPO XHD Tread Safe Bonding Tool,per manufacturers published Plates through to wood supports instructions. max.24-inch o.c. ABLE IG: ••• rCONSTRUCTION, ••• • RECOVER ATTACHED.J SYSTEM TYPE D-1:INSULATED,MECHANICALLY ROOF COVER System Deck Insulation(Note 13) Roof Cover MDP No. (Note 1) Type Attach Separator Sheet(Optional) Membrane Fasteners(Note 11) Attachment (psf) One or more EverGuard Polymat Separation 6-inch o.c.within 5.5-inch wide laps Min.19/32-inch plywood or Prelim. Layer(3 oz/yd)or EverGuard EverGuard Drill-Tec#14 Fastener with Drill-Tec 2 in. W-80. layers,any spaced 114.5-inch o.c.and sealed -45.0 1-inch wood plank;2 ft span combination attached Polymat Cushioning Layer(6 TPO Double Barbed XHD Plates with a 1.75-inch heat weld. oz/ydz) One or more EverGuard Polymat Separation 6-inch o.c.within 6-inch wide laps APA rated,19/32 CAT,0.578 Prelim. Layer(3 oz/ydz)or EverGuard EverGuard Drill-Tec XHD with Drill-Tec 2-3/8 in. W 81. in.,Exposure 1 OSB layers,any attached Polymat Cushioning Layer(6 TPO Barbed XHD Plates spaced 54-inch o.c.and sealed with -45.0 combination oz/yd') a 1.5-inch heat weld. One or more EverGuard Polymat Separation 6-inch o.c.within 5-inch wide laps Min.19/32-inch plywood or Prelim. Layer(3 oz/yd)or EverGuard EverGuard Drill-Tec#14 Fastener with Drill-Tec 2 in. W 82. 1-inch wood plank;2 ft span layers,any attached Polymat Cushioning Layer(6 TPO Double Barbed XHD Plates spaced 55-inch o.c.and sealed with -52.5 combination oz/ydz) a 1.75-inch heat weld. Min.15/32-inch plywood, EverGuard Polymat Separation Drill-Tec#14 Fastener with Drill-Tec 2 in. 12-inch o.c.within 6-inch wide laps W-83. layers, min.19/32-inch OSB or 1- One s,more Prelim. Layer(3 oz/ydz)or EverGuard EverGuard Double Barbed XHD Plates fastened spaced 48-inch o.c.(over wood inch wood lank over No.2 any attached Polymat CushioningLayer 6 TPO through deck to joists)and sealed with a 1.5-inch -52.5 P combination y y ( g engage e g g wood joists, ) wood trusses;2 ft span oz/ydz) minimum 1-inch embedment into joist heat weld. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 18 of 156 NNEMO etc. TABLE IG:WOOD DECKS .. SYSTEM TYPE• INSULATED,MECHANICALLY ATTACHED ROOF System Deck Insulation(Note 13) Roof Cover MDP Separator Sheet(Optional) No. (Note 1) Type Attach Membrane Fasteners(Note 11) Attachment (psf) Min.15/32-inch plywood, EverGuard Polymat Separation Drill-Tec#14 Fastener with Drill-Tec 2 in. 6-inch o.c.within 6-inch wide laps min.19/32-inch OSB or 1- One or more Prelim. Layer(3 oz/ydz)or EverGuard EverGuard Double Barbed XHD Plates fastened spaced 48-inch o.c.(over wood ,W-84. layers any -67.5 inch wood plank over No.2 attached Polymat Cushioning Layer(6 TPO through deck to engage wood joists, joists)and sealed with a 1.5-inch wood trusses;2 ft span combination oz/ydz) minimum 1.5-inch embedment into joist heat weld. Min.15/32-inch plywood, EverGuard Polymat Separation Drill-Tec#14 Fastener with Drill-Tec 2- 12-inch o.c.within 6-inch wide laps W 85 ,any min.19/32-inch O56 or 1- layers One or more Prelim. Layer(3 oz/ydz)or EverGuard EverGuard 3/4 in. Barbed SXHD Plates fastened spaced 48-inch o.c.(over wood -67.5 inch wood plank over No.2 attached Polymat Cushioning Layer(6 TPO through deck to engage wood joists, joists)and sealed with a 1.5-inch wood trusses;2 ft span combination oz/yd2) I I minimum 1-inch embedment into joist heat weld. TABLE 1H:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER �STEM TYPE D-2:INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) 7 Base or Anchor Sheet MDP No. (Note 1) Type Attach Base Fasteners(Note 11) Attach Roof Cover (psf) Min.15/32-inch Drill-Tec#14 Fastener with Drill-Tec 3"Steel One or more GAF StormSafe Anchor 18-inch o.c.at min.4-inch lap and EverGuard plywood or 1-inch Loose- Plate or Drill-Tec 3 in.Ribbed Galvalume Plate W-86. layers,any Sheet(Max.48-inch 18-inch o.c.at two,equally Freedom TPO/ -45.0* wide) wood plank,2 ft laid (Flat)or Drill-Tec#14 HD Fastener with Drill-Tec span combination 3"Flat Steel Plate spaced,staggered center rows self adhered Min.19/32-inch One or more GAF StormSafe Anchor Drill-Tec#14 Fastener with Drill-Tec 3 in. 8-inch o.c.at min.4-inch lap and EverGuard W 87 plywood or inch layers,any Loose- ,ft Sheet(Max.48-inch Ribbed Galvalume Plate(Flat)or Drill-Tec#14 8-inch o.c.at two,equally spaced, Freedom TPO/ -60.0* span Loose- wood plank;2 combination laid wide) HD Fastener with Drill-Tec 3"Flat Steel Plate staggered center rows self adhered TABLE 1i: ••• rCONSTRUCTION, ••• • RECOVER SYSTEM TYPE E-1: • • MECHANICALLY ATTACHED ROOF COVER System Separator Sheet Roof Cover MDP No. Deck(Note 1) (Optional) Membrane Fasteners(Note 11) Attachment (psf) Min.19/32-inch plywood or 1- EverGuard Polymat Separation Layer(3 EverGuard Drill-Tec#14 Fastener with Drill-Tec 2 in.Double 6-inch o.c.within 5.5-inch wide laps W 88. inch wood plank;2 ft span oz/yd)or EverGuard Polymat Cushioning Eve Barbed XHD Plates spaced 114.5-inch o.c.and sealed -45.0 Layer(6 oz/yd) TPOwith a 1.75-inch heat weld. APA rated,19/32 CAT,0.578 in., EverGuard Polymat Separation Layer(3 EverGuard Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed XHD 6-inch o.c.within 6-inch wide laps W 89' Exposure 1 OSB oz/yd2)or EverGuard Polymat Cushioning TPO Plates spaced 54-inch o.c.and sealed with a -45.0 Layer(6 oz/ydz) 1.5-inch heat weld. Min.19 32-inch I EverGuard Polymat Separation Layer(3 6-inch o.c.within 5-inch wide laps W 90 / plywood or 1- oz/yd2)or EverGuard Polymat Cushioning EverGuard Barbed #14 Fastener with Drill-Tec 2 in.Double spaced 55-inch o.c.and sealed with a -52.5 inch wood plank;2 ft span Layer(6 oz/ydz) TPO Barbed XHD Plates 1.75-inch heat weld. Min.15/32-inch plywood,min. EverGuard Polymat Separation Layer(3 Drill-Tec#14 Fastener with Drill-Tec 2 in.Double 12-inch o.c.within 6-inch wide laps 19/32-inch OSB or 1-inch wood EverGuard W 91' plank over No.2 wood trusses; oz/yd2)or EverGuard Polymat Cushioning TPO Barbed XHD Plates fastened through deck to engage spaced 48-inch o.c.(over wood joists) -60.0 2 a Layer(6 oz/yd) wood joists,minimum 1-inch embedment into joist and sealed with a 1.5-inch heat weld. span 11 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 19 of 156 NNEMO I etc. TABLE Ir WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E-1:NON-INSULATED,MECHANICALLY ATTACHED ROOF COVER System Deck(Note 1) Separator Sheet Roof Cover MDP No. (Optional) Membrane Fasteners(Note 11) Attachment (psf) Min.15/32-inch plywood,min. EverGuard Polymat Separation Layer(3 Drill-Tec#14 Fastener with Drill-Tec 2 in.Double 6-inch o.c.within 6-inch wide laps W 92 19/32-inch OSB or 1-inch wood oz/yd2)or EverGuard Polymat Cushioning EverGuard Barbed XHD Plates fastened through deck to engage spaced 48-inch o.c.(over wood joists) -67.5 plank over No.2 wood trusses;2 ft span Layer(6 oz/yd2) TPO wood joists,minimum 1.5-inch embedment into joist and sealed with a 1.5-inch heat weld. Min.15/32-inch plywood,min. 19/32-inch OSB or 1-inch wood EverGuard Polymat Separation Layer(3 EverGuard Drill-Tec#14 Fastener with Drill-Tec 2-3/4 in. Barbed 12-inch o.c.within 6-inch wide laps W-93. oz/yd2)or EverGuard Polymat Cushioning SXHD Plates fastened through deck to engage wood spaced 48-inch o.c.(over wood joists) -75.0 plank over No.2 wood trusses; Layer(6 oz/yd') TPO joists,minimum 1-inch embedment into joist and sealed with a 1.5-inch heat weld. 2 ft span TABLE 1i:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER EL SYSTEM TYPE E-2:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVE�� System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners(Note 11) F Attach Base Cap (psf) EverGuard Freedom TPO: Min.19/32-inch GAF StormSafe Anchor Sheet 32 ga.,1-5/8-inch diameter tin 9-inch o.c.at min.4-inch plywood or 1-inch (Max.40-inch wide or lapped to caps with 11 ga.annular ring lap and 9-inch o.c.at two, EverGuard Freedom W-94' wood lank;2 ft produce max.36-inch wide la shank nails new or reroof only; equally spaced,staggered None TPO -45.0 P P P- ( Y q Y P gg span to-lap spacing) no recover) center rows Min.15/32-inch 32 ga.,1-5/8-inch diameter tin 6-inch o.c.at min.4-inch W 95 plywood or 1-inch GAF StormSafe Anchor Sheet caps with 12 ga.x 1.25-inch lap and 6-inch o.c.at two, None EverGuard Freedom -45.0* wood plank;2 ft (Max.48-inch wide) annular ring shank nails(new or equally spaced,staggered TPO span reroof only;no recover) center rows Min.15/32-inch Drill-Tec#14 Fastener with Drill- 18-inch o.c.at min.4-inch Tec 3 in.Ribbed Galvalume plywood or 1-inch GAF StormSafe Anchor Sheet lap and 18-inch o.c.at two, EverGuard Freedom W 96' wood plank;2 ft (Max.48-inch wide) Plate(Flat)or Drill-Tec#14 HD equally spaced,staggered None TPO -45.0* Fastener with Drill-Tec 3"Flat span Steel Plate center rows Min.19/32-inch Drill-Tec#14 Fastener with Drill- 8-inch o.c.at min.4-inch plywood or 1-inch GAF StormSafe Anchor Sheet lap and 8-inch o.c.at two, EverGuard Freedom W 97' Tec 3 in.Ribbed Galvalume wood plank;2 ft (Max.48-inch wide) Plate(Flat)or Drill-Tec#14 HD equally spaced,staggered None TPO -67.5* Fastener with Drill-Tec 3"Flat span Steel Plate center rows Drill-Tec#12 or#14 Fastener Min.19/32-inch GAF StormSafe Anchor Sheet with Drill-Tec 3"Steel Plates or 8-inch o.c.at min.4-inch plywood or 1-inch (Max.40-inch wide or lapped to Drill-Tec 3 in.Ribbed Galvalume lap and 8-inch o.c.at EverGuard Freedom W-98' wood plank;2 ft produce max.36-inch wide lap- Plate(Flat)or Drill-Tec#14 HD three,equally spaced, None TPO 105.0 span to-lap spacing) Fastener with Drill-Tec 3"Flat staggered center rows Steel Plate Hybrid System: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 20 of 156 NNEMO I etc. TABLE 1j: DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E-2:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners(Note 11) Attach Base Cap (psf) GAFGLAS#75 Base Sheet,Tri-Ply (Optional)One or two plies Ruberoid 20 Min.15/32-inch #75 Base Sheet,GAFGLAS#80 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.4-inch Smooth,Ruberoid Mop Smooth,Ruberoid EverGuard TPO plywood or 1-inch with 12 ga.annular ring shank laps and 8-inch o.c.in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece-Back W-99' wood plank;2 ft Ultima Base Sheet,GAFGLAS nails(new or reroof only;no equally spaced,staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot -45.0 span Stratavent Nailable Venting Base Sheet,Ruberoid 20 Smooth recover) center rows Smooth or Ruberoid HW Smooth,torch- apshalt applied (Optional)One or two plies Ruberoid 20 Min.19/32-inch GAFGLAS#80 Ultima Base Sheet, 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at min.4-inch Smooth,Ruberoid Mop Smooth,Ruberoid EverGuard TPO plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga.annular ring shank laps and 9-inch o.c.in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece-Back W-100. -45.0 wood plank;2 ft Venting Base Sheet,Ruberoid 20 nails(new or reroof only;no equally spaced,staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Smooth recover) center rows Smooth or Ruberoid HW Smooth,torch- apshalt applied GAFGLAS#75 Base Sheet,Tri-Ply (Optional)One or two plies Ruberoid 20 Min.15/32-inch #75 Base Sheet,GAFGLAS#80 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at min.4-inch Smooth,Ruberoid Mop Smooth,Ruberoid EverGuard TPO plywood or 1-inch with 12 ga.annular ring shank laps and 6-inch o.c.in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece-Back W-101. wood plank;2 ft Ultima Base Sheet,GAFGLAS nails(new or reroof only;no equally spaced,staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot -52.5 span Stratavent Nailable Venting Base Sheet,Ruberoid 20 Smooth recover) center rows Smooth or Ruberoid HW Smooth,torch- apshalt applied GAFGLAS#75 Base Sheet,Tri-Ply (Optional)One or two plies Ruberoid 20 Min.15/32-inch #75 Base Sheet GAFGLAS#80 16-inch o.c.at 4-inch laps Smooth,Ruberoid Mop Smooth,Ruberoid EverGuard TPO , plywood or 1-inch and 16-inch o.c.in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece-Back W-102. wood plank;2 ft Ultima Base Sheet,GAFGLAS Note 2(#14 ONLY) equally spaced,staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot -52.5 span Stratavent Nailable Venting Base center rows Smooth or Ruberoid HW Smooth,torch- apshalt Sheet,Ruberoid 20 Smooth applied GAFGLAS#75 Base Sheet,Tri-Ply (Optional)One or two plies Ruberoid 20 Min.15/32-inch #75 Base Sheet,GAFGLAS#80 12-inch o.c.at 4-inch laps Smooth,Ruberoid Mop Smooth,Ruberoid EverGuard TPO plywood or 1-inch and 12-inch o.c.in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece-Back W-103. wood plank;2 ft Ultima Base Sheet,GAFGLAS Note 2(#14 ONLY) equally spaced,staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot -60.0 span Stratavent Nailable Venting Base Sheet,Ruberoid 20 Smooth center rows Smooth or Ruberoid HW Smooth,torch- apshalt applied (Optional)One or two plies Ruberoid 20 Min.19/32-inch GAFGLAS#80 Ultima Base Sheet, 32 ga.,1-5/8-inch dia.tin caps 8-inch the 4-inch lap Smooth,Ruberoid Mop Smooth,Ruberoid EverGuard TPO W-104. plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga.annular ring shank and 8-inch o.o.c.in three Mop Smooth 1.5 or Ruberoid Mop Plus Fleece-Back -75.0 wood plank;2 ft Venting Base Sheet,Ruberoid 20 nails(new or reroof only;no staggered center rows Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Smooth recover) Smooth or Ruberoid HW Smooth,torch- apshalt applied NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 21 of 156 NNEMO etc. TABLE 1j: DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E-2:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners(Note 11) Attach Base Cap (psf) Min.19/32-inch GAFGLAS#75 Base Sheet,Tri-Ply 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at min.2-inch Ruberoid 20 Smooth,Ruberoid Mop Smooth EverGuard TPO #75 Base Sheet,GAFGLAS#80 1.5,Ruberoid Mop Smooth,Ruberoid Mop plywood or 1-inch with 11 ga.annular ring shank laps and 4-inch o.c.at four Fleece-Back W-105. wood plank;2 ft Ultima Base Sheet,GAFGLAS nails(new or reroof only;no (4),equally spaced, Plus Smooth/hot asphalt or Ruberoid HW Membrane in hot -97.5 span Stratavent Nailable Venting Base recover) staggered center rows Smooth,Ruberoid HW 25 Smooth/torch- apshalt Sheet,Ruberoid 20 Smooth applied GAFGLAS#75 Base Sheet,Tri-Ply (Optional)One or two plies Ruberoid 20 Min.15/32-inch #75 Base Sheet,GAFGLAS#80 8-inch o.c.at 4-inch laps Smooth,Ruberoid Mop Smooth,Ruberoid EverGuard TPO Ultima Base Sheet plywood or 1-inch and 8-inch o.c.in three, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece-Back W-106. wood plank;2 ft Sheet,Ruberoid 20 Smooth,GAFGLAS Note 2(#14 ONLY) equally spaced,staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot 97.5 span Stratavent Nailable Venting Base center rows Smooth or Ruberoid HW Smooth,torch- apshalt applied GAFGLAS#75 Base Sheet,Tri-Ply One or two plies Ruberoid 20 Smooth, EverGuard TPO Min.15/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.4-inch Fleece-Back #75 Base Sheet,GAFGLAS#80 Ruberoid Mop Smooth,Ruberoid Mop plywood or 1-inch with 12 ga.annular ring shank laps and 8-inch o.c.in two, Membrane in GAF 2- W-107. wood plank;2 ft Ultima Base Sheet,GAFGLAS nails(new or reroof only;no equally spaced,staggered Smooth 1. or Ruberoid Mop Plus Smooth in part(spatter),LRF-XF -45.0 span Stratavent Nailable Venting Base recover) center rows hot asphaltt or Ruberoid HW 25 Smooth or (spatter)or OB500 Sheet,Ruberoid 20 Smooth Ruberoid HW Smooth,torch-applied (spatter) One or two plies Ruberoid 20 Smooth, EverGuard TPO Min.19/32-inch GAFGLAS#80 Ultima Base Sheet, 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at min.4-inch Fleece-Back plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga.annular ring shank laps and 9-inch o.c.in two, Ruberoid Mop Smooth,Ruberoid Mop Membrane in GAF 2- W-108. Smooth 1 -45.0 wood plank;2 ft Venting Base Sheet,Ruberoid 20 nails(new or reroof only;no equally spaced,staggered .5 or Ruberoid Mop Plus Smooth in part(spatter),LRF-XF span Smooth recover) center rows hot asphalt or Ruberoid HW 25 Smooth or (spatter)or OB500 Ruberoid HW Smooth,torch-applied (spatter) GAFGLAS#75 Base Sheet,#80 Ruberoid Mop Smooth,Ruberoid Mop Tri-Ply One or two plies Ruberoid 20 Smooth, EverGuard TPO #75 Base Sheet,GAFGLAS Min.15/32-inch 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at min.4-inch Fleece-Back plywood or 1-inch with 12 ga.annular ring shank laps and 6-inch o.c.in two, Membrane in GAF 2- W-109. wood plank;2 ft Ultima Base Sheet,GAFGLAS nails(new or reroof only;no equally spaced,staggered Smooth 1.t or Ruberoid HW 25 Smooth or or Ruberoid Mop Plus Smooth in part(spatter),LRF-XF -52.5 hot asphalt span Stratavent Nailable Venting Base recover) center rows (spatter)or OB500 Sheet,Ruberoid 20 Smooth Ruberoid HW Smooth,torch-applied (spatter) GAFGLAS#75 Base Sheet,Tri-Ply One or two plies Ruberoid 20 Smooth, EverGuard TPO Min.15/32-inch 16-inch o.c.at 4-inch laps Fleece-Back #75 Base Sheet,GAFGLAS#80 Ruberoid Mop Smooth,Ruberoid Mop plywood or 1-inch and 16-inch o.c.in two, Membrane in GAF 2- W-110. wood plank;2 ft Ultima Base Sheet,GAFGLAS Note 2(#14 ONLY) equally spaced,staggered Smooth 1.5 or Ruberoid Mop Plus Smooth in part(spatter),LRF-XF -52.5 span Stratavent Nailable Venting Base center rows hot asphalt or Ruberoid HW 25 Smooth or (spatter)or OB500 Sheet,Ruberoid 20 Smooth Ruberoid HW Smooth,torch-applied (spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 22 of 156 NNEMO I etc. TABLE 1j: DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E-2:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners(Note 11) Attach Base Cap (psf) GAFGLAS#75 Base Sheet,Tri-Ply One or two plies Ruberoid 20 Smooth, EverGuard TPO Min.15/32-inch 12-inch o.c.at 4-inch laps Fleece-Back #75 Base Sheet,GAFGLAS#80 Ruberoid Mop Smooth,Ruberoid Mop plywood or 1-inch and 12-inch o.c.in two, Membrane in GAF 2- W-111. wood plank;2 ft Ultima Base Sheet,GAFGLAS Note 2(#14 ONLY) equally spaced,staggered Smooth 1.5 or Ruberoid Mop Plus Smooth in Part(spatter),LRF-XF -60.0 Stratavent Nailable Venting Base hot asphalt or Ruberoid HW 25 Smooth or span Sheet,Ruberoid 20 Smooth center rows Ruberoid HW Smooth,torch-applied (spatter)or OB500 (spatter) One or two plies Ruberoid 20 Smooth EverGuard TPO , Min.19/32-inch GAFGLAS#80 Ultima Base Sheet, 32 ga.,1-5/8-inch dia.tin caps Fleece-Back Ruberoid Mop plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga.annular ring shank 8-inch o.c.at the 4-inch lap Ruberoid Mop Smooth, Membrane in GAF 2- W-112. wood plank;2 ft Venting Base Sheet,Ruberoid 20 nails(new or reroof only;no and 8-inch o.c.in three Smooth 1.5 or Ruberoid Mop Plus Smooth in Part(spatter),LRF-XF -75.0 span Smooth recover) staggered center rows hot asphalt or Ruberoid HW 25 Smooth or (spatter)or OB500 Ruberoid HW Smooth,torch-applied (spatter) Min.19/32-inch GAFGLAS#75 Base Sheet,Tri-Ply 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at min.2-inch Ruberoid 20 Smooth,Ruberoid Mop Smooth EverGuard TPO #75 Base Sheet,GAFGLAS#80 1.5,Ruberoid Mop Smooth,Ruberoid Mop Fleece-Back plywood or 1-inch with 11 ga.annular ring shank laps and 4-inch o.c.at four W-113. wood plank;2 ft Ultima Base Sheet,GAFGLAS nails(new or reroof only;no (4),equally spaced, Plus Smooth/hot asphalt or Ruberoid HW Membrane in GAF 2- -97.5 span Stratavent Nailable Venting Base recover) staggered center rows Smooth,Ruberoid HW 25 Smooth/torch- Part(spatter)or LRF- Sheet,Ruberoid 20 Smooth applied XF(spatter) Min.15/32-inch GAFGLAS#75 Base Sheet,Tri-Ply 8-inch o.c.at 4-inch laps One or two plies Ruberoid 20 Smooth, EverGuard TPO pl #75 Base Sheet,GAFGLAS#80 Ruberoid Mop Smooth,Ruberoid Mop Fleece-Back ywood or 1-inch and inch in three, W-114. wood plank;2 ft Ultima Base Sheet,GAFGLAS Note 2(#14 ONLY) equally spaced, ,staggered Smooth 1.5 or Ruberoid Mop Plus Smooth in Membrane in GAF 2- -97.5 Stratavent Nailable Venting Base hot asphalt or Ruberoid HW 25 Smooth or Part(spatter)or LRF- span Sheet,Ruberoid 20 Smooth center rows Ruberoid HW Smooth,torch-applied XF(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 23 of 156 NNEMO etc. TABLE 2A:STEEL DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck Insulation MDP No. (Note 1) Type Attach(Notes 6,7,9) Roof Cover(Note 15) (Psf) EverGuard TPO: S-1. Min.22 ga.,type B,Grade 40 steel Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M or OB500,6"o.c. EverGuard TPO/TPO QSA or TPO QSA LV50 -82.5 S-2. Min.22 ga.,type B,Grade 40 steel Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M or OB500,6"o.c. EverGuard TPO/#1121,TPO 6-Square,TPO 3-Square,WB181 -120.0 EverGuard TPO Fleece-Back Membrane in Spatter Applications: S-3. Min.22 ga.,type B,Grade 40 steel Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M or OB500,6"o.c. EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter),LRF- _120.0 XF(spatter)or OB500(spatter) TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type At Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,a) EverGuard Freedom TPO: Min.22 ga.,Type B,Grade 1 per Min.0.5-inch EnergyGuard RH HD Polyiso LRF-M or EverGuard Freedom TPO/self S-4. 33 steel or min.2,500 psi Min.1.5-inch EnergyGuard RH Note 2 2.0 ft2 Insulation,EnergyGuard HD Polyiso Insulation, OB500 adhered -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min.22 ga.,Type B,Grade 1 per Min.0.5-inch EnergyGuard RH HD Polyiso LRF-M or EverGuard Freedom TPO/self S-5. 33 steel or min.2,500 psi Min.2-inch EnergyGuard RH Note 2 2.9 ft2 Insulation,EnergyGuard HD Polyiso Insulation, OB500 adhered -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard RA, 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard Freedom TPO/self S-6. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 2.0 ft2 Board or OB500 adhered -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard RA, 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard Freedom TPO/self S-7. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Board or OB500 adhered -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard Freedom TPO/self S-8. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min.0.25-inch LRF-M or adhered -45.0* structural concrete SECUROCK Gypsum-Fiber Roof Board OB500 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard Freedom TPO/self 4 S-9. 33 steel or min.2,500 psi Note 2 insulation followed by Min.0.25-inch LRF-M or -45.0* structural concrete Insulation,EnergyGuard Ultra .0 ft� SECUROCK Gypsum-Fiber Roof Board OB500 adhered Min.22 ga.,Type B,Grade GAF 2-Part, 5-10. 33 steel or min.2,500 psi Min Insulation, E EnergyGuard Polyiso Note 2 1 per Additional optional layers,min.0.5-inch base LRF-M or EverGuard Freedom TPO/self -45.0* structural concrete Insulation,EnergyGuard Ultra 2.0 ft2 insulation OB500 adhered Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard Freedom TPO/self 5-11. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation LRF-M or adhered -45.0* structural concrete OB500 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 24 of 156 NNEMO etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part, EverGuard Freedom TPO/self 5-12. 33 steel or min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board LRF-M or adhered -52.5 structural concrete OB500 Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard RA 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard Freedom TPO/self 5-13. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 adhered -60.0 structural concrete Min.22 ga.,Type B,Grade 5-14. 33 steel or min.2,500 psi Min ch EnergyGuard RA or Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard Freedom TPO/self _45.0* EnergyGuard RH 2.0 ft2Board adhered structural concrete Min.22 ga.,Type B,Grade 5-15. 33 steel or min.2,500 psi Min G EnergyGuard RA or Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard Freedom TPO/self -45.0* structural concrete EnergyGuard RH 4.0 ft2Board adhered Min.22 ga.,Type B,Grade Additional optional layers,min.0.5-inch base 5-16. 33 steel or min.2,500 psi Min 1.5-inch EnergyGuard Polyiso Note 2 1 pe insulation followed by Min.0.25-inch LRF-XF EverGuard Freedom TPO/self -45.0* structural concrete Insulation,EnergyGuard Ultra 2.0 ft2SECUROCK Gypsum-Fiber Roof Board adhered Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard Freedom TPO/self 5-17. 33 steel or min.2,500 psi Insulation 4 Note 2 insulation followed by Min.0.25-inch LRF-XF -45.0* structural concrete ,EnergyGuard Ultra .0 ft� SECUROCK Gypsum-Fiber Roof Board adhered Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard Freedom TPO/self 5-18. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-XF adhered -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard Freedom TPO/self 5-19. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation LRF-XF adhered -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard Freedom TPO/self 5-20. 33 steel or min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF adhered -52.5 structural concrete Min.22 ga.,Type B,Grade 5-21. 33 steel or min.2,500 psi Min.2-inch EnergyGuard RA or Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard Freedom TPO/self -60.0 structural concrete EnergyGuard RH 1.6 ft2Board adhered EverGuard TPO: Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard RA or 1 per EverGuard TPO/#1121,TPO 3- 5-22. 33 steel or min.2,500 psi EnergyGuard RN Note 2 2.0 ft� Additional layers of base insulation Hot asphalt Square,WB181 -45.0* structural concrete Min.22 el ga.,Type B,Grade Min.2-inch EnergyGuard RA or 1 per EverGuard TPO/#1121,TPO 3- 5-23. 33 steel min.2,500 psi EnergyGuard RN Note 2 4 0 ft2 Additional layers of base insulation Hot asphalt Square,WB181 -45.0* structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 25 of 156 NNEMO I etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard RA, 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/#1121,TPO 6- 5-24. 33 steel or min.2,500 psi EnergyGuard RN,EnergyGuard RH Note 2 3.2 ft2 Gypsum-Fiber Roof Board OB5o0 Square,TPO 3-Square,WB181 -37.5* structural concrete Min.22 ga.,Type B,Grade 1 per Min.0.5-inch EnergyGuard RH HD Polyiso LRF-M or EverGuard TPO/#1121,TPO 6- 5-25. 33 steel or min.2,500 psi Min.1.5-inch EnergyGuard RH Note 2 2.0 ft2 Insulation,EnergyGuard HD Polyiso Insulation, OB500 Square,TPO 3-Square,WB181 -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min.22 ga.,Type B,Grade 1 per Min.0.5-inch EnergyGuard RH HD Polyiso LRF-M or EverGuard TPO/#1121,TPO 6- 5-26. 33 steel or min.2,500 psi Min.2-inch EnergyGuard RH Note 2 2 9 per ft� Insulation,EnergyGuard HD Polyiso Insulation, OB500 F-M Square,EverGuard TTPO 3-Square,,TPO -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 1 per One or more layers of Base Insulation or min. GAF 2-Part EverGuard TPO/#1121,TPO 3- 5-27. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 0.5-inch thick DensDeck or OB500 Square -45.0* structural concrete Min.22 ga.,Type B,Grade 5-28. 33 steel or min.2,500 psi Min.0.5-inch DensDeck Note 2 1 per One or more layers,min.1.5-inch EnergyGuard GAF 2-Part EverGuard TPO/#1121,TPO 3- _45.0* structural concrete 2.0 ft2 Polyiso Insulation,EnergyGuard Ultra or OBS00 Square,WB181 Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso Insulation,EnergyGuard Ultra, 1 per 5-29. 33 steel or min.2,500 psi EnergyGuard RA,EnergyGuard RN, Note 2 2 0 ft� Min.0.5-inch Fiber Base HD1,Fiber Base HD6 OB500 EverGuard TPO/WB181 -45.0* structural concrete EnergyGuard RH Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard RA, 1 per Min.0.5-inch Structodek High Density EverGuard TPO/#1121,TPO 6- 5-30. 33 steel or min.2,500 psi EnergyGuard RN,EnergyGuard RH Note 2 2.0 ft2 Fiberboard Roof Insulation OB500 Square,TPO 3-Square -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base LRF-M or EverGuard TPO/#1121,TPO 6- 5-31. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2ft� insulation followed by Min.0.5-inch Structodek OB500 Square,TPO 3-Square -45.0* structural concrete High Density Fiberboard Roof Insulation Min.22 ga.,Type B,Grade Additional optional layers,min.0.5-inch base 5-32. 33 steel or min.2,500 psi Min 2-inch EnergyGuard Polyiso Note 2 1 per insulation followed by Min.0.5-inch Structodek OB500 or EverGuard 3-/3-Sq#112uare TPO 6- _45.0* structural concrete Insulation,EnergyGuard Ultra 4.0 ftz High Density Fiberboard Roof Insulation OB500 Square,TPO 3-Square Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard RA, 1 per Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO/#1121,TPO 6- 5-33. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 2.0 ft2 Gypsum-Fiber Roof Board or OB500 Square,TPO 3-Square,WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard RA, 1 per Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO/#1121,TPO 6- 5-34. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Gypsum-Fiber Roof Board or OB500 Square,TPO 3-Square,WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/#1121,TPO 6- 5-35. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min.0.25-inch DensDeck LRF-M or Square,TPO 3-Square,WB181 -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board OB500 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 26 of 156 NNEMO I etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/#1121,TPO 6- 5-36. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4 structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board OB500 Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/#1121,TPO 6- 5-37. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-M or Square,TPO 3-Square,WB181 -45.0* structural concrete OB500 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-PaPa or EverGuard TPO/#1121,TPO 6- 5-38. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation LRF-M or Square,TPO 3-Square,WB181 -45.0* structural concrete OB500 Min.22 ga.,Type B,Grade GAF 2-Part, 5-39. 33 steel or min.2,500 psi Min Insulation, EnergyGuard Polyiso Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-M or EverGuard 3-/#1123-Square TPO 6- -52.5 structural concrete Insulation,EnergyGuard RH 2.0 ft2Board OB500 Square,TPO 3-Square Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard RA, 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/#1121,TPO 6- 5-40. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 Square,TPO 3-Square,WB181 -60.0 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/#1121,TPO 6- 5-41. t steel orl concrete EnergyGuard RH or EnergyGuard RN min.2,500 psi Insulation,EnergyGuard RA, Note 2 1.3 ft2 Board or OB500 Square,TPO 3-Square,WB181 -60.0 structural Min.22 ga.,Type 3,Grade Min.3-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500,4- 5-42. 80 steel or min.2,500 psi Insulation or EnergyGuard Ultra Note 2 1.0 ft2 Board inch o.c. EverGuard TPO/#1121 -120.0 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/#1121,TPO 6- 5-43. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M Square,TPO 3-Square,WB181 -60.0 structural concrete EnergyGuard RN Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard RA or 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/#1121,TPO 6- 5-44. 33 steel or min.2,500 psi EnergyGuard RH Note 2 2.0 ft2 Gypsum-Fiber Roof Board LRF-XF Square,TPO 3-Square,WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade 5-45. 33 steel or min.2,500 psi Min 2-inch EnergyGuard RA or Note 2 1 per Min.0.25-inch DensDeck Prime or SECUROCK LRF-XF EverGuard TPO/#1121,TPO 6- _45.0 structural concrete * EnergyGuard RH 4.0 ft2 Gypsum-Fiber Roof Board Square,TPO 3-Square,WB181 Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/#1121,TPO 6- 5-46. 33 steel or min.2,500 psi Insulation EnergyGuard Ultra Note 2 2 0 ft� insulation followed by Min.0.25-inch DensDeck LRF-XF Square,TPO 3-Square,W6181 -45.0* , structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/#1121,TPO 6- 5-47. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4 0 per insulation followed by Min.0.25-inch DensDeck LRF-XF Square,EverGuard TTPO 3-Square,,TPO -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 27 of 156 NNEMO I etc. TABLE 2B:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MOP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/#1121,TPO 6- 5-48. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-XF Square,TPO 3-Square,WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/#1121,TPO 6- 5-49. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation LRF-XF Square,TPO 3-Square,WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/#1121,TPO 6- 5-50. 33 steel or min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF Square,TPO 3-Square -52.5 structural concrete Min.22 ga.,Type B,Grade 5-51. 33 steel or min.2,500 psi Min.2-inch EnergyGuard RA or Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard TPO/#1121,TPO 6- _60.0 structural concrete EnergyGuard RH 1.6 ft2Board Square,TPO 3-Square,W6181 Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 5-52. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard TPO/#1121,TPO 6- -60.0 structural concrete I EnergyGuard RH 1.3 ft2 Board Square,TPO 3-Square,WB181 EverGuard TPO/EverGuard TPO Quick Spray or EverGuard TPO Quick Spray LV SO: Min.22 ga.,Type B,Grade 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/TPO QSA or 5-53. 33 steel or min.2,500 psi Min.1.5-inch EnergyGuard RA Note 2 3.2 ft2 Gypsum-Fiber Roof Board OB500 TPO QSA LV50 -37.5* structural concrete Min.22 ga.,Type B,Grade 1 per One or more layers,min.1.5-inch EnergyGuard GAF 2-Part EverGuard TPO/TPO QSA or 5-54. 33 steel or min.2,500 psi Min.0.5-inch DensDeck Note 2 2.0 ft2 Polyiso Insulation or OB500 TPO QSA LV50 -45.0* structural concrete Min.22 ga.,Type B,Grade 5-55. 33 steel or min.2,500 psi Min 1.5-inch EnergyGuard RA, Note 2 1 per Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO/TPO QSA or _q5.0* structural concrete EnergyGuard RN or EnergyGuard RH 2.0 ft2Gypsum-Fiber Roof Board or OB500 TPO QSA LV50 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard RA, 1 per Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO/TPO QSA or 5-56. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Gypsum-Fiber Roof Board or OB500 TPO QSA LV50 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/TPO QSA or 5-57. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft' insulation followed by Min.0.25-inch DensDeck LRF-M or TPO QSA LV50 -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board OB500 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/TPO QSA or 5-58. 33 steel or min.2,500 psi Insulation EnergyGuard Ultra Note 2 4 0 fti insulation followed by Min.0.25-inch DensDeck LRF-M or Eve QSA LV50 -45.0* , structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board OB500 TPO Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/TPO QSA or 5-59. 33 steel or min.2,500 psi Insulation Note 2 2.0 ft2 insulation LRF-M or TPO QSA LV50 -45.0* structural concrete OB500 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 28 of 156 NNEMO I etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/TPO QSA or 5-60. 33 steel or min.2,500 psi Insulation Note 2 q.0 ft2 insulation LRF-M or TPO QSA LV50 -45.0* structural concrete OB500 Min.22 ga.,Type B,Grade GAF 2-Part Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof , EverGuard TPO/TPO QSA or 5-61. 33 steel or min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board LRF-M or TPO QSA LV50 -52.5 structural concrete OB500 Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard RA, 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/TPO QSA or 5-62. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 TPO QSA LV50 -60.0 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 5-63. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/TPO QSA or -60.0 structural concrete EnergyGuard RH or EnergyGuard RN 1.3 ft2 Board or OBS00 TPO QSA LV50 Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 5-64. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-M EverGuard TPO/TPO QSA or -60.0 structural concrete EnergyGuard RN 1.3 ft2 Board TPO QSA LV50 Min.22 ga.,Type B,Grade Min.3-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500,4- EverGuard TPO/TPO QSA or 5-65. 80 steel or min.2,500 psi Insulation or EnergyGuard Ultra Note 2 1.0 ft2 Board inch o.c. TPO QSA LV50 82.5 structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard RA or 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/TPO QSA or 5-66. 33 steel or min.2,500 psi EnergyGuard RH Note 2 2.0 ft2 Gypsum-Fiber Roof Board LRF-XF TPO QSA LV50 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard RA or 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/TPO QSA or 5-67. 33 steel or min.2,500 psi EnergyGuard RH Note 2 4.0 ft2 Gypsum-Fiber Roof Board LRF-XF TPO QSA LV50 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/TPO QSA or 5-68. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min.0.25-inch DensDeck LRF-XF TPO QSA LV50 -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B,Grade Additional optional layers,min.0.5-inch base 5-69. 33 steel or min.2,500 psi Min 2-inch EnergyGuard Polyiso Note 2 1 per z insulation followed by Min.0.25-inch DensDeck LRF-XF EverGuard TPO/TPO QSA or _45.0* structural concrete Insulation,EnergyGuard Ultra 4.0 ft prime or SECUROCK Gypsum-Fiber Roof Board TPO QSA LV50 Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/TPO QSA or 5-70. 33 steel or min.2,500 psi Insulation Note 2 2.0 ftz insulation LRF-XF TPO QSA LV50 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/TPO QSA or 5-71. 33 steel or min.2,500 psi Insulation Note 2 4.0 ft2 insulation LRF-XF TPO QSA LV50 -45.0* structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 29 of 156 NNEMO etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/TPO QSA or 5-72. 33 steel or min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF TPO QSA LV50 -52.5 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard RA or 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/TPO QSA or 5-73. 33 steel or min.2,500 psi EnergyGuard RH Note 2 1.6 ft2 Board LRF-XF TPO QSA LV50 -60.0 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 perMin.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/TPO QSA or 5-74. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 Board LRF-XF TPO QSA LV50 -60.0 structural concrete EnergyGuard RH EverGuard TPO/FastLayn TPO Adhesive: Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso GAF 2-Part, 1 per Min.0.5-inch EnergyGuard HD Polyiso hot asphalt, EverGuard TPO/FastLayn TPO 5-75. t steel orl concrete Insulation min.2,500 psi Insulation,EnergyGuard Ultra Polyiso Note 2 1.8 ft2 Insulation LRF-M or Adhesive -30.0 structural OB500 Min.22 ga.,Type B,Grade 1 per EverGuard TPO/FastLayn TPO 5-76. 33 steel or min.2,500 psi Min.1.5-inch EnergyGuard RA Note 2 2 0 ft2 Additional layers of base insulation hot asphalt Adhesive -45.0* structural concrete Min.22 ga.,Type B,Grade 1 per EverGuard TPO/FastLayn TPO 5-77. 33 steel or min.2,500 psi Min.2-inch EnergyGuard RA Note 2 1 ft2 Additional layers of base insulation hot asphalt Adhesive -45.0* structural concrete 4. Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard RA, 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/FastLayn TPO 5-78. 33 steel or min.2,500 psi EnergyGuard RN,EnergyGuard RH Note 2 3.2 ftz Gypsum-Fiber Roof Board OB500 Adhesive -37.5* structural concrete Min.22 ga.,Type B,Grade 1 per Min.0.5-inch EnergyGuard HD Polyiso LRF-M or EverGuard TPO/FastLayn TPO 5-79. 33 steel or min.2,500 psi Min.1.5-inch EnergyGuard RH Note 2 2.0 ft' Insulation OB500 Adhesive -37.5* structural concrete Min.22ga.,Type B,Grade 1 per Min.0.5-inch EnergyGuard HD Polyiso LRF-M or EverGuard TPO/FastLayn TPO 5-80. t steelel structural l concrete min.2,500 psi Min.2-inch EnergyGuard RH Note 2 2.9 ft2 Insulation OB500 Adhesive -37.5* s st Min.22 ga.,Type B,Grade 5-81. 33 steel or min.2,500 psi Min.1.5-inch EnergyGuard Polyiso Note 2 1 per a Additional layers of base insulation GAF 2-Part EverGuard TPO/FastLayn TPO -45.0* structural concrete Insulation 2.0 ft2 or OB500 Adhesive Min.22 ga.,Type B,Grade 1 per One or more layers,min.1.5-inch EnergyGuard GAF 2-Part EverGuard TPO/FastLayn TPO 5-82. 33 steel or min.2,500 psi Min.0.5-inch DensDeck Note 2 2.0 ft2 Polyiso Insulation or OB500 Adhesive -45.0* structural concrete Min.22 ga.,Type B,Grade 5-83. 33 steel or min.2,500 psi Min 1.5-inch EnergyGuard RA, Note 2 1 per Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO/FastLayn TPO -45.0* structural concrete EnergyGuard RN or EnergyGuard RH 2.0 ft2Gypsum-Fiber Roof Board or OB500 Adhesive NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 30 of 156 NNEMO I etc. TABLE 2B:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard RA, 1 per Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-PaEverGuard TPO/FastLayn TPO 5-84. 33 steel or min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Gypsum-Fiber Roof Board or OB500Adhesive -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-PaEverGuard TPO/FastLayn TPO 5-85. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min.0.25-inch DensDeck LRF-M or]Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board OB500 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base GAF 2-Part, EverGuard TPO/FastLayn TPO 5-86. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation followed by Min.0.25-inch DensDeck LRF-M or Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board OB500 Min.22 ga.,Type B,Grade GAF 2-Part, 5-87. 33 steel or min.2,500 psi Min 1.5-inch EnergyGuard Polyiso Note 2 1 per i Additional optional layers,min.0.5-inch base LRF-M or EverGuard TPO/FastLayn TPO -45.0* structural concrete Insulation 2.0 ft insulation OB500 Adhesive Min.22 ga.,Type B,Grade GAF 2-Part, 5-88. 33 steel or min.2,500 psi Min inch EnergyGuard Polyiso Note 2 per Additional optional layers,min.0.5-inch base LRF-M or EverGuard TPO/FastLayn TPO -45.0* structural concrete OB500 Insulation 4.0 ft2insulation Adhesive Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part, EverGuard TPO/FastLayn TPO 5-89. 33 steel or min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board LRF-M or Adhesive -52.5 structural concrete OB500 Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard RA, 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/FastLayn TPO 5-90. steel min.2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 Adhesive -60.0 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/FastLayn TPO 5-91. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 1.3 ft2 Board or OB500 Adhesive -60.0 structural concrete EnergyGuard RH or EnergyGuard RN Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/FastLayn TPO 5-92. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M Adhesive -60.0 structural concrete EnergyGuard RN Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min. inch EnergyGuard HD Polyiso EverGuard TPO/FastLayn TPO 5-93. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Polyiso Note 2 1.8 ft2 Insulation LRF-XF Adhesive -30.0 structural concrete Insulation Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 1 per EverGuard TPO/FastLayn TPO 5-94. 33 steel or min.2,500 psi Insulation Note 2 2.0 ft' Additional layers of base insulation LRF-XF Adhesive -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard RA or 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/FastLayn TPO 5-95. 33 steel or min.2,500 psi EnergyGuard RH Note 2 2.0 ft2 Gypsum-Fiber Roof Board LRF-XF Adhesive -45.0* structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 31 of 156 NNEMO I etc. TABLE 2B:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard RA or 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/FastLayn TPO 5-96. 33 steel or min.2,500 psi EnergyGuard RH Note 2 4.0 ft2 Gypsum-Fiber Roof Board LRF-XF Adhesive -45.0* structural concrete Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/FastLayn TPO 5-97. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min.0.25-inch DensDeck LRF-XF Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO/FastLayn TPO 5-98. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation followed by Min.0.25-inch DensDeck LRF-XF Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B,Grade 5-99. 33 steel or min.2,500 psi Min inch EnergyGuard Polyiso Note 2 1 per Additional optional layers,min.0.5-inch base LRF-XF EverGuard TPO/FastLayn TPO -45.0* structural concrete Insulation 2.0 ft2insulation Adhesive Min.22 ga.,Type B,Grade 5-100. 33 steel or min.2,500 psi Min inch EnergyGuard Polyiso Note 2 per Additional optional layers,min.0.5-inch base LRF-XF EverGuard TPO/FastLayn TPO -45.0* structural concrete Insulation 4..0 ft2insulation Adhesive Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/FastLayn TPO 5-101. 33 steel or min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF Adhesive -52.5 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard RA or 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/FastLayn TPO 5-102. 33 steel or min.2,500 psi EnergyGuard RH Note 2 1.6 ft2 Board LRF-XF Adhesive -60.0 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO/FastLayn TPO 5-103. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 ft2 Board LRF-XF Adhesive -60.0 structural concrete EnergyGuard RH EverGuard TPO Fleece-Back Membrane in EverGuard WB 181 Bonding Adhesive: Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-104. 33 steel or min.2,500 psi Note 2 0B500 -45.0* structural concrete Insulation,EnergyGuard Ultra 2.0 ft2 insulation Membrane/W6181 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-105. 33 steel or min.2,500 psi Note 2 0B500 -45.0* structural concrete Insulation,EnergyGuard Ultra 4.0 ft� insulation Membrane/W6181 Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard RA, 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back 5-106. 33 steel or min.2,500 psi EnergyGuard RN,EnergyGuard RH Note 2 3.2 ft2 Gypsum-Fiber Roof Board OB500 Membrane/WB181 -37.5* structural concrete Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso Insulation,EnergyGuard Ultra, 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back 5-107. 33 steel or min.2,500 psi EnergyGuard RA,EnergyGuard RN, Note 2 2.0 ftz Gypsum-Fiber Roof Board OB500 Membrane/WB181 -45.0* structural concrete EnergyGuard RH NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 32 of 156 NNEMO I etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back 5-108. t steelel structural concrete OB500 min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 Gypsum-Fiber Roof Board Membrane/WB181 -45.0* st Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back 5-109. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 1.3 ft2 Board OB500 Membrane/WB181 -60.0 structural concrete EnergyGuard RH or EnergyGuard RN Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-110. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-M Membrane/WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-111. 33 steel or min.2,500 psi Note 2 LRF-M -45.0* structural concrete Insulation,EnergyGuard Ultra 4.0 ft2 insulation Membrane/W6181 Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-112. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min.0.25-inch DensDeck LRF-M Membrane/WB181 -45.0* structural concrete Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-113. 33 steel or min.2,500 psi Insulation 4 Note 2 insulation followed by Min.0.25-inch DensDeck LRF-M -45.0* structural concrete ,EnergyGuard Ultra .0 ft� prime or SECUROCK Gypsum-Fiber Roof Board Membrane/WB181 Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back 5-114. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M Membrane/WB181 -60.0 structural concrete EnergyGuard RN Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-115. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 insulation LRFAF Membrane/WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-116. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation LRFAF Membrane/WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back 5-117. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 ft2 Board LRFAF Membrane/WB181 -60.0 structural concrete EnergyGuard RH Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-118. 33 steel or min.2,500 psi Note 2 GAF 2-Part -45.0* structural concrete Insulation,EnergyGuard Ultra 2.0 ft� insulation Membrane/WB181 Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers,min.0.5-inch base EverGuard TPO Fleece-Back 5-119. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 insulation GAF 2-Part Membrane/WB181 -45.0* structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 33 of 156 NNEMO I etc. TABLE 2B:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back S-120. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 1.3 ft2 Board GAF 2-Part Membrane/WB181 -60.0 structural concrete EnergyGuard RH or EnergyGuard RN EverGuard TPO Fleece-Back Membrane in LRF Adhesive M or LRF Adhesive O: Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back S-121. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 pft2er Gypsum-Fiber Roof Board OB500 Membrane/LRF-M or LRF-0, -45.0* structural concrete 12-inch o.c. Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back S-122. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 Gypsum-Fiber Roof Board OB500 Membrane/LRF-M or LRF-0, -45.0* structural concrete 12-inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back S-123. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 3 2 er followed by Min.0.25-inch DensDeck Prime or OB500 Membrane/LRF-M or LRF-0,4- -30.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 1 per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back S-124. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 2 0 fti followed by Min.0.25-inch DensDeck Prime or OB500 Membrane/LRF-M or LRF-0,4- -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back S-125. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 Z 9 erft2 followed by Min.0.25-inch DensDeck Prime or OB500 Membrane/LRF-M or LRF-O,4- -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type 3,Grade Min.2-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back 1 S-126. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 1 pe i Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 Membrane/LRF-M or LRF-O,4- -60.0 structural concrete EnergyGuard RH or EnergyGuard RN .3 ft2 Board inch o.c. Min.22 ga.,Type B,Grade Min 1.5-inch EnergyGuard Polyiso 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back S-127. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 2.0 ft2 Gypsum-Fiber Roof Board LRF-M Membrane/LRF-M or LRF-O, -45.0* structural concrete 12-inch o.c. Min.22 ga.,Type B,Grade Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back S-128. 33 steel or min.2,500 psi Insulation,EnergyGuard Ultra Note 2 4.0 ft2 Gypsum-Fiber Roof Board LRF-M Membrane/LRF-M or LRF-0, -45.0* structural concrete 12-inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-129. 33 steel or min.2,500 psi Insulation,EnergyGuard RH per , Note 2 3.2 ft' followed by Min.0.25-inch DensDeck Prime or LRF-M Membrane/LRF-M or LRF-0,4- -30.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 1 per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back S-130. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 2 O er followed by Min.0.25-inch DensDeck Prime or LRF-M Membrane/LRF-M or LRF-0,4- -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back S-131. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 1 per followed by Min.0.25-inch DensDeck Prime or LRF-M Membrane/LRF-M or LRF-O,4- -45.0* structural concrete EnergyGuard RN 2.9 ft2SECUROCK Gypsum-Fiber Roof Board inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 34 of 156 NNEMO I etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back 5-132. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1 LRF-M Membrane/LRF-M or LRF-0,4- -60.0 structural concrete EnergyGuard RN .3 ft� Board inch o.c. Min.22 ga.,Type 3,Grade Min.2-inch EnergyGuard Polyiso Note per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-133. 33 steel or min.2,500 psi Note 2 i followed by Min.0.25-inch DensDeck Prime or LRF-XF Membrane/LRF-M or LRF-O,4- -30.0* structural concrete Insulation or EnergyGuard RH 3.2 ft SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type 3,Grade Min.1.5-inch EnergyGuard Polyiso 1 per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-134. 33 steel or min.2,500 psi Insulation EnergyGuard RH Note 2 2 0 erft2 followed by Min.0.25-inch DensDeck Prime or LRF-XF Membrane/LRF-M or LRF-O,4- -45.0* structural concrete SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-135. 33 steel or min.2,500 psi Insulation or EnergyGuard RH Note 2 2ft� followed by Min.0.25-inch DensDeck Prime or _RF-XF Membrane/LRF-M or LRF-O,4- -45.0* structural concrete SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back 1 5-136. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 LRF-XF Membrane/LRF-M or LRF-0,4- -60.0 structural concrete EnergyGuard RH .3 ft� Board inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-137. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 3.2 ft� followed by Min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/LRF-M or LRF-0,4- -30.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type 3,Grade Min.1.5-inch EnergyGuard Polyiso 1 per Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-138. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 2 perft2 followed by Min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/LRF-M or LRF-O,4- -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 er Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-139. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 2 9 fti followed by Min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/LRF-M or LRF-O,4- -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Min.22 ga.,Type 3,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back 5-140. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 GAF 2-Part Membrane/LRF-M or LRF-O,4- -60.0 structural concrete EnergyGuard RH or EnergyGuard RN 1.3 ft: Board inch o.c. EverGuard TPO Fleece-Back Membrane in Spatter Applications: Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso Optional layers of 1 per min.0.5-inch base insulation EverGuard TPO Fleece-Back Membrane/GAF 2-Part 5-141. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 i followed by Min.0.25-inch DensDeck Prime or OB500 -30.0* structural concrete EnergyGuard RN 3.2 ft SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OB500(spatter) Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-142. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 1 per followed by Min.0.25-inch DensDeck Prime or OB500 Membrane/GAF 2-Part -45.0* structural concrete EnergyGuard RN 2.0 ft2 SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 35 of 156 NNEMO I etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-143. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 1 per followed by Min.0.25-inch DensDeck Prime or OB500 Membrane/GAF 2-Part -45.0* structural concrete EnergyGuard RN 2.9 ft2 SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OB500(spatter) Min.22 ga.,Type B,Grade EverGuard TPO Fleece-Back Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof Membrane/GAF 2-Part 5-144. t steel orl concrete min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board OB500 (spatter),LRF-XF(spatter)or -52.5 structural OB500(spatter) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per EverGuard TPO Fleece-Back 5-145. 33 steel or min.2,500 psi Insulation Note 2 1 8 ft2 Min.1.5-inch x max.4x4 ft base insulation OB500 Membrane/OB500(spatter) -60.0 structural concrete Optional layers of min.1.5-inch x max.44 ft Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per base insulation followed by min.0.25-inch x EverGuard TPO Fleece-Back 1 5-146. 33 steel or min.2,500 psi Note 2 max.4x4 ft DensDeck Prime or SECUROCK OB500 -60.0 structural concrete Insulation .8 ft� Gypsum-Fiber Roof Board or min.0.5-inch x Membrane/OB500(spatter) max.44 ft EnergyGuard HD Polyiso Insulation EverGuard TPO Fleece-Back Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof 5-147. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 13 ft2 Board OB500 (spatter),LRF-XF(spatter)Membrane/GAF Part spatter)or -60.0 structural concrete EnergyGuard RH or EnergyGuard RN . OB500(spatter) Min.22 ga.,Type B,Grade Min.0.25-inch SECUROCK Gypsum-Fiber Roof 5-148. 33 steel or min.2,500 psi Min. tinch EnergyGuard Polyiso Note 2 1 per Board or or min.0.5-inch x max.4x4 ft OB500 EverGuard Fleece-Back Insulation 1 -67.5 structural concrete on .8 ft2 EnergyGuard HD Polyiso Insulation Membrane//O OB500(spatter) Min.22 ga.,Type B,Grade Min.3-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof 013500,4- EverGuard TPO Fleece-Back 5-149. 80 steel or min.2,500 psi Insulation or EnergyGuard Ultra Note 2 1.0 ft2 Board inch o.c. Membrane/OB500(spatter) -120.0 structural concrete Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-150. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 1 per followed by Min.0.25-inch DensDeck Prime or LRF-M Membrane/GAF 2-Part -30.0* structural concrete EnergyGuard RN 3.2 ft2 SECUROCK Gypsum-Fiber Roof Board (spatter),LRF (spatter)or OB500(spatter) Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso Optional layers of 1 per min.0.5-inch base insulation EverGuard TPO Fleece-Back Membrane/GAF 2-Part 5-151. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 followed by Min.0.25-inch DensDeck Prime or LRF-M -45.0* structural concrete EnergyGuard RN 2.0 ft2 SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OB500(spatter) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard G Fleece-Back 5-152. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 .per followed by Min.0.25-inch DensDeck Prime or LRF-M Membrane//GAF spPart 2 9 ft2 -45.0* structural concrete EnergyGuard RN OB500(spatter) SECUROCK Gypsum-Fiber Roof Board (spatter),LRF (spatter)or NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 36 of 156 NNEMO etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade EverGuard TPO Fleece-Back 5-153. 33 steel or min.2,500 psi Min 2-inch EnergyGuard Polyiso Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-M Membrane/GAF 2-Part -52.5 structural concrete Insulation,EnergyGuard RH 2.0 ft2 Board (spatter),LRF-XF(spatter)or OB500(spatter) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof Membrane/GAF 2-Part 5-154. 33 steel or min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M (spatter),LRF-XF(spatter)or -60.0 structural concrete EnergyGuard RN OB500(spatter) Min.22 ga.,Type B,Grade Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-155. 33 steel or min.2,500 psi Min.2-inch EnergyGuard Polyiso Note 2 1 per followed by Min.0.25-inch DensDeck Prime or LRF-XF Membrane/GAF 2-Part -30.0* structural concrete Insulation or EnergyGuard RH 3.2 ft� SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OBS00(spatter) Min.22 ga.,Type B,Grade Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back Min.1.5-inch EnergyGuard Polyiso 1 per Membrane/GAF 2-Part 5-156. 33 steel or min.2,500 psi Insulation or EnergyGuard RH Note 2 2.0 ft2 followed by Min.0.25-inch DensDeck Prime or LRF-XF (spatter),LRF-XF(spatter)or -45.0* structural concrete SECUROCK Gypsum-Fiber Roof Board OB500(spatter) Min.22 ga.,Type B,Grade Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-157. 33 steel or min.2,500 psi Min.2-inch EnergyGuard Polyiso Note 2 1 per followed by Min.0.25-inch DensDeck Prime or LRF-XF Membrane/GAF 2-Part -45.0* structural concrete Insulation or EnergyGuard RH 2.9 ft� SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OB500(spatter) Min.22 ga.,Type B,Grade EverGuard TPO Fleece-Back 5-158. 33 steel or min.2,500 psi Min 2-inch EnergyGuard Polyiso Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF Membrane/GAF 2-Part -52.5 structural concrete Insulation or EnergyGuard RH 2.0 ft2 Board (spatter),LRF-XF(spatter)or 0B500(spatter) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof Membrane/GAF 2-Part 5-159. steel min.2,500 psi Insulation,EnergyGuard RA or Note 2 1.3 ft2 Board LRF-XF (spatter),LRF-XF(spatter)or -60.0 structural st concrete EnergyGuard RH OB500(spatter) Min.22 ga.,Type 3,Grade Min.2-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard Fleece-Back /G Membrane/G 5-160. 33 steel or min.2,500 psi Insulation,EnergyGuard RH 3, Note 2 .per (spatter),LRF followed by Min.0.25-inch DensDeck Prime or GAF 2-Part Fleece-Back (spatter)or -30.0* structural concrete EnergyGuard RN 2 ft� SECUROCK Gypsum-Fiber Roof Board OBS00(spatter) (sp Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-161. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 1 per followed by Min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/GAF 2-Part -45.0* structural concrete EnergyGuard RN 2.0 ft' SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 37 of 156 NNEMO I etc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover(Note 15) (Psf) (Note 11) (Notes 6,7,8) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso Optional layers of min.0.5-inch base insulation EverGuard TPO Fleece-Back 5-162. 33 steel or min.2,500 psi Insulation,EnergyGuard RH, Note 2 1 per followed by Min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/GAF 2-Part -45.0* structural concrete EnergyGuard RN 2.9 ft2 SECUROCK Gypsum-Fiber Roof Board (spatter),LRF-XF(spatter)or OB500(spatter) Min.22 ga.,Type B,Grade EverGuard TPO Fleece-Back Min 2-inch EnergyGuard Polyiso 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof Membrane/GAF 2-Part 5-163. t steel orl concrete min.2,500 psi Insulation,EnergyGuard RH Note 2 2.0 ft2 Board GAF 2-Part (spatter),LRF-XF(spatter)or -52.5 structural OB500(spatter) Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso EverGuard TP0 Fleece-Back 5-164. 33 steel or min.2,500 psi Insulation,EnergyGuard RA, Note 2 1 per Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part Membrane/GAF 2-Part -60.0 structural concrete EnergyGuard RH or EnergyGuard RN 1.3 ft� Board (spatter),LRF-XF(spatter)or OB500(spatter) TABLE 2c:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED BASE AND CAP PLY System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) F�7 No. (Note 1) Type Fasten Attach Type Attach(Notes 6,7,8) Base Ply Cap Ply (Note 11) Asphalt-Applied Base Ply: Optional layers of base GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type Min 1.5-inch EnergyGuard insulation followed by Ply#75 Base Sheet,GAFGLAS B,Grade 33 steel 1 per Min.0.25-inch DensDeck, #80 Ultima Base Sheet, EverGuard TPO Fleece-Back 5-165. or min.2,500 psi Polyiso Insulation,EnergyGuard Note 2 2.0 ft2 DensDeck Prime or Hot asphalt Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt -45.0* structural concrete Ultra SECUROCK Gypsum-Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5/hot asphalt Optional layers of base GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type insulation followed by Ply#75 Base Sheet,GAFGLAS 5-166. B,Grade 33 steel Min 1.5-inch EnergyGuard RA, Note 2 1 per Min.0.25-inch DensDeck, Hot asphalt #80 Ultima Base Sheet, EverGuard TPO Fleece-Back -45.0* or min.2,500 psi EnergyGuard RN 4.0 ft2DensDeck Prime or Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt structural concrete SECUROCK Gypsum-Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5/hot asphalt Optional layers of min. GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type 0.5-inch base insulation Ply#75 Base Sheet,GAFGLAS B,Grade 33 steel Min 2-inch EnergyGuard Polyiso Note 2 1 per followed by Min.0.25-inch #80 Ultima Base Sheet, EverGuard TPO Fleece-Back -45.0* 5-167. or min.2,500 psi Insulation,EnergyGuard Ultra 4.0 ft2 DensDeck,DensDeck Hot asphalt Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt structural concrete Prime or SECUROCK Mop Smooth or Ruberoid Mop Gypsum-Fiber Roof Board Smooth 1.5/hot asphalt NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 38 of 156 NNEMO I etc. TABLE 2c:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED B Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Base Ply Cap Ply (psf) (Note 11) (Notes 6,7,8) Optional layers of min. GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type 1.5-inch base insulation Ply#75 Base Sheet,GAFGLAS B,Grade 33 steel 1 per followed by Min.0.25-inch #80 Ultima Base Sheet, EverGuard TPO Fleece-Back 5-168. or min.2,500 psi Min 2-inch EnergyGuard RA Note 2 5.3 ft2 DensDeck,DensDeck Hot asphalt Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt -45.0* structural concrete Prime or SECUROCK Mop Smooth or Ruberoid Mop Gypsum-Fiber Roof Board Smooth 1.5/hot asphalt Optional layers of base GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type insulation followed by Ply#75 Base Sheet,GAFGLAS B,Grade 33 steel Min 1.5-inch EnergyGuard RA or Note 2 1 per Min.0.25-inch DensDeck, GAF 2-Part #80 Ultima Base Sheet, EverGuard TPO Fleece-Back -45.0* 5-169. or min.2,500 psi EnergyGuard RN 2.0 W DensDeck Prime or or OB500 Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt structural concrete SECUROCK Gypsum-Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5/hot asphalt Optional layers of min. GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type 1.5-inch base insulation Ply#75 Base Sheet,GAFGLAS B Note 2,Grade 33 steel Min 2-inch EnergyGuard RA or 1 per followed by Min.0.25-inch GAF 2-Part #80 Ultima Base Sheet, EverGuard TPO Fleece-Back -45.0* 5-170. or min.2,500 psi EnergyGuard RN 4.0 ft2 DensDeck,DensDeck or OB500 Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt structural concrete Prime or SECUROCK Mop Smooth or Ruberoid Mop Gypsum-Fiber Roof Board Smooth 1.5/hot asphalt Min.22 ga.,Type Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back B,Grade 33 steel, Polyiso Insulation,EnergyGuard 1 per Min.0.25-inch SECUROCK GAF 2-Part Ruberoid 20 Smooth/hot Membrane/hot asphalt,GAF 2- 5-171. or min.2,500 psi RA,EnergyGuard RH, Note 2 1.3 ft2 Gypsum-Fiber Roof Board or OB500 asphalt Part(spatter),LRF-XF(spatter) -60.0 structural concrete EnergyGuard RM or or OB500(spatter)or LRF-O,12- EnergyGuard RN inch o.c. Optional layers of base GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type Ply#75 Base Sheet,GAFGLAS insulation followed by 5-172. B,Grade 33 steel Min 1.5-inch EnergyGuard RA Note 2 1 per Min.0.25-inch DensDeck LRF-XF #80 Ultima Base Sheet, EverGuard TPO Fleece-Back -45.0* or min.2,500 psi 2.0 ft2Prime or SECUROCK Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt structural concrete Mop Smooth or Ruberoid Mop Gypsum-Fiber Roof Board Smooth 1.5/hot asphalt Optional layers of min. GAFGLAS#75 Base Sheet,Tri- Min.22 ga.,Type 1.5-inch base insulation Ply#75 Base Sheet,GAFGLAS B,Grade 33 steel 1 per followed by Min.0.25-inch #80 Ultima Base Sheet, EverGuard TPO Fleece-Back 5-173. or min.2,500 psi Min 2-inch EnergyGuard RA Note 2 4.0 ft2 DensDeck Prime or LRF-XF Ruberoid 20 Smooth,Ruberoid Membrane/hot asphalt -45.0* structural concrete SECUROCK Gypsum-Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5/hot asphalt NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 39 of 156 NNEMO etc. TABLE 2c:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED B Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Base Ply Cap Ply (psf) (Note 11) (Notes 6,7,8) EverGuard TPO Fleece-Back Min.22 ga.,Type Min.1.5-inch EnergyGuard Membrane/hot asphalt,GAF 2- 5-174. B,Grade 33 steel, Polyiso Insulation,EnergyGuard Note 2 1 per Min.0.25-inch SECUROCK LRF-XF Ruberoid 20 Smooth/hot Part(spatter),LRF-XF(spatter) -60.0 or min.2,500 psi RA or EnergyGuard RH 1.3 ft2 Gypsum-Fiber Roof Board asphalt or OB500(spatter)or LRF-O,12- structural concrete inch o.c. Torch-Applied Base Ply: Min.22 ga.,Type B, Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back Grade 33 steel,or Polyiso Insulation,EnergyGuard 1 per Min.0.25-inch SECUROCK GAF 2-Part Ruberoid HW 25 Smooth/ Membrane/hot asphalt,GAF 2- 5-175. min.2,500 psi RA,EnergyGuard RH, Note 2 1.3 ft2 Gypsum-Fiber Roof Board or OB500 torch-applied Part(spatter),LRF-XF(spatter) -60.0 structural concrete EnergyGuard RM or or OB500(spatter)or LRF-O,12- EnergyGuard RN inch o.c. Min.22 ga.,Type B, EverGuard TPO Fleece-Back Grade 33 steel,or Min.1.5-inch EnergyGuard 1 per Min.0.25-inch SECUROCK Ruberoid HW 25 Smooth/ Membrane/hot asphalt,GAF 2- 5-176. Polyiso Insulation,EnergyGuard Note 2 LRF-XF Part(spatter),LRF-XF(spatter) -60.0 min.2,500 psi RA or EnergyGuard RH 1.3 ft2 Gypsum-Fiber Roof Board torch-applied or OB500(spatter)or LRF-O,12- structuralconcrete inch o.c. Self-Adhering Base Ply: Min.22 ga.,Type B, Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back Grade 33 steel,or Polyiso Insulation,EnergyGuard 1 per Min.0.25-inch SECUROCK GAF 2-Part Liberty SBS Self-Adhering Cap Membrane/hot asphalt,GAF 2- 5-177. min.a 33 psi RA,EnergyGuard RH, Note 2 1.3 ft2 Gypsum-Fiber Roof Board or OB500 Sheet/self-adhered Part(spatter),LRF-XF(spatter) -60.0 structural concrete EnergyGuard RM or or OB500(spatter)or LRF-0,12- EnergyGuard RN inch o.c. Min.22 ga.,Type B, EverGuard TPO Fleece-Back Min.1.5-inch EnergyGuard Membrane/hot asphalt,GAF 2- Grade 33 steel,or 1 per Min.0.25-inch SECUROCK Liberty SBS Self-Adhering Cap 5-178. Polyiso Insulation,EnergyGuard Note 2 LRF-XF Part(spatter),LRF-XF(spatter) -60.0 min. psi RA or EnergyGuard RH .3 ft2 Gypsum-Fiber Roof Board Sheet/self-adhered or OBS00(spatter)or LRF-0,12- structural uralconcrete 1 inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 40 of 156 *NEMO I etc. TABLE 2D:STEEL DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF) SYSTEM TYPE B-2:MECHANICALLY ATTACHED THERMAL BARRIER,BONDED TEMP ROOF,BONDED BONDED ROOF Thermal Barrier Insulation Layer(s)System Deck Temp Roof Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (Notes 6,7,8) (Psf) EverGuard Freedom TPO: Min.22 ga., Note 2(Drill-Tec 3 in. Grade 33 Min.0.5-inch Min.1.5-inch EnergyGuard RH followed by Min. Ribbed Galvalume steel or min. SECUROCK 1 per Liberty SBS Self-Adhering 0.5-inch EnergyGuard RH HD Polyiso Insulation, EverGuard Freedom TPO/ 5-179. 2,500 psi Gypsum-Fiber Plate(Flat)may be 2.7 ft' Cap Sheet,self-adhering EnergyGuard HD Polyiso Insulation,EnergyGuard OB500 self adhered -45.0* structural Roof Board used)(no recessed HD Plus Polyiso Insulation concrete plate) 0.5-inch Primer:GAF SA Primer or One or more layers,base layer min.1-inch thick, Min.22 ga., DensDeck Note 2(Drill-Tec 3 in. Matrix 307 Premium optional subsequent layer(s)min.1.5-inch thick Ribbed Galvalume EnergyGuard RN Type B, Prime or 1 per Asphalt Primer LRF-M or EverGuard Freedom TPO/ 5-180. Plate(Flat)may be (Optional)Min.0.25-inch DensDeck Prime or -45.0* Grade 33 SECUROCK used)(no recessed 4.0 ft2 Vapor Retarder: GAF SA SECUROCK Gypsum-Fiber Roof Board or min.0.5- OB500 self adhered steel Gypsum Fiber plate) Vapor Retarder,self- inch EnergyGuard HD Polyiso Insulation or Roof Board adhering EnergyGuard HD Plus Polyiso Insulation One or more layers,base layer min.1-inch thick, 0.5-inch Primer:GAF SA Primer or optional subsequent layer(s)min.1.5-inch thick Min.22 ga., DensDeck Note 2(Drill-Tec 3 in. Matrix 307 Premium EnergyGuard Polyiso Insulation,EnergyGuard GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Asphalt Primer Ultra Polyiso Insulation LRF-M,LRF- EverGuard Freedom TPO/ 5-181. Plate(Flat)may be -45.0* Grade 33 SECUROCK 4.0 ft2 Vapor Retarder: GAF SA (Optional)Min.0.25-inch DensDeck Prime or XF or self adhered steel Gypsum Fiber used)(no recessed Vapor Retarder,self- SECUROCK Gypsum-Fiber Roof Board or min.0.5- OB500 Roof Board plate) adhering inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation 0.5-inch Note 2(Drill-Tec 3 in. One or more layers,base layer min.1-inch thick, Min.22 ga., DensDeck Primer:GAF SA Primer GAF 2-Part, Ribbed Galvalume optional subsequent layer(s)min.1.5-inch thick Type B, Prime or 1 per Vapor Retarder: GAF SA LRF-M,LRF- EverGuard Freedom TPO/ 5-182. Grade 33 SECUROCK Plate(Flat)may be 2.0 ft� Vapor Retarder,self- EnergyGuard Polyiso Insulation,EnergyGuard XF or self adhered -60.0 steel Gypsum Fiber used)(no recessed Ultra Polyiso Insulation followed by Min.0.25- adhering OB500 Roof Board plate) inch SECUROCK Gypsum-Fiber Roof Board EverGuard TPO: Min.22 ga., Note 2(Drill-Tec 3 in. Grade 33 Min.0.5-inch Min.1.5-inch EnergyGuard RH followed by Min. Ribbed Galvalume EverGuard re, /O 3- steel or min. SECUROCK 1 per Liberty SBS Self-Adhering 0.5-inch EnergyGuard RH HD Polyiso Insulation, 5-183. 2,500 psi Gypsum-Fiber Plate(Flat)may be 2 7 ft� Cap Sheet,self-adhering EnergyGuard HD Polyiso Insulation,EnergyGuard OB500 TPO 6-Square,TPO 3- -45.0* structural Roof Board used)(no recessed HD Plus Polyiso Insulation Square,W6181 concrete plate) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 41 of 156 *NEMO I etc. TABLE 21):STEEL DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF) SYSTEM TYPE B-2:MECHANICALLY ATTACHED THERMAL BARRIER,BONDED TEMP ROOF,BONDED BONDED ROOF Thermal Barrier Insulation Layer(s)System Deck Temp Roof Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (Notes 6,7,8) (Psf) Min.22 ga., Note 2(Drill-Tec 3 in. Grade or SECURn. OCK Ribbed Ribbed Galvalume Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/#1121, steel or min. SECUROCK 1 per Liberty SBS Self-Adhering 5-184. 2,500 psi Gypsum-Fiber Plate(Flat)may be 2.7 ft2 Cap Sheet,self-adhering EnergyGuard Ultra,EnergyGuard RA, OB500 TPO 6-Square,TPO 3- -45.0* structural Roof Board used)(no recessed EnergyGuard RN Square,WB181 concrete plate) Min.22 ga., Note 2(Drill-Tec 3 in. Min.1.5-inch EnergyGuard Polyiso Insulation, Grade 33 Min.0.5-inch Ribbed Galvalume EnergyGuard Ultra,EnergyGuard RA, EverGuard TPO/#1121, steel or min. SECUROCK 1 per Liberty SBS Self-Adhering 5-185. Plate(Flat)may be i EnergyGuard RN followed by Min.0.25-inch OB500 TPO 6-Square,TPO 3- -45.0* 2,500 psi Gypsum-Fiber used)(no recessed 2.7 ft Cap Sheet,self-adhering DensDeck Prime or SECUROCK Gypsum-Fiber Square,WB181 structural Roof Board plate) Roof Board concrete Min.22 ga., 3 Grade 33 Note 2(Drill-Tec 3 in. Ribbed Galvalume Two plies GAFGLAS Ply 4, EverGuard TPO/#1121, 5-186. steel or min. Min.0.625-inch Plate(Flat)may be 1 per i GAFGLAS Ply 4 M, Min.1.5-inch EnergyGuard RA hot asphalt TPO 6-Square,TPO 3- -45.0* 2,500 psi DensDeck used)(no recessed 4.0 ft applied in hot asphalt or OB500 Square structural concrete plate) Min.22 ga., Note 2(Drill-Tec 3 in. Grade 33 Min.0.5-inch Ribbed Galvalume Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/#1121, steel or min. SECUROCK 1 per Liberty SBS Self-Adhering 5-187. Plate(Flat)may be EnergyGuard Ultra,EnergyGuard RA, OB500 TPO 6-Square,TPO 3- -45.0* 2,500 psi Gypsum-Fiber used)(no recessed 2.7 ft2 Cap Sheet,self-adhering EnergyGuard RN,EnergyGuard RH Square,WB181 structural Roof Board plate) concrete Min.22 ga., 3 Grade 33 Min. inch Note 2(Drill-Tec3 in. Min.1.5-inch EnergyGuard Polyiso Insulation, steel or min. SECUROCK 1 per Liberty SBS Self-Adhering Ribbed Galvalume EnergyGuard Ultra,EnergyGuard RA, EverGuard TPO/#1121, 5-188. Plate(Flat)may be EnergyGuard RN,EnergyGuard RH followed by OB500 TPO 6-Square,TPO 3- -45.0* 2,500 psi Roof BoarGypsum-Fd used)(no recessed 2.7 ft2 Cap Sheet,self-adhering min.0.25-inch DensDeck Prime or SECUROCK Square,WB181 structural Roof Board plate) Gypsum-Fiber Roof Board concrete 0.5-inch Primer:GAF SA Primer or One or more layers,base layer min.1-inch thick, Matrix 307 Premium Min.22 ga., DensDeck Note 2(Drill-Tec 3 in. optional subsequent layer(s)min.1.5-inch thick Ribbed Galvalume EnergyGuard RN EverGuard TPO/#1121, Type B, Prime or 1 per Asphalt Primer LRF-M or 5-189. Plate(Flat)may be (Optional)Min.0.25-inch DensDeck Prime or TPO 6-Square,TPO 3- -45.0* Grade 33 SECUROCK 4.0ft2 Vapor Retarder: GAF SA OB500 steel Gypsum Fiber used)(no recessed Vapor Retarder,self- nchSEC ROCK Gypsum-FiberRoof Board or min.0.5- Square,W6181 i Roof Board plate) adhering nch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 42 of 156 *NEMO I etc. TABLE 21):STEEL DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF) SYSTEM TYPE B-2:MECHANICALLY ATTACHED THERMAL BARRIER,BONDED TEMP ROOF,BONDED TOP INSULATION,BONDED ROOF COVER Thermal Barrier Insulation Layer(s)System Deck Temp Roof Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (Notes 6,7,8) (Psf) One or more layers,base layer min.1-inch thick, 0.5-inch Primer:GAF SA Primer or optional subsequent layer(s)min.1.5-inch thick Note 2(Drill-Tec 3 in. Min.22 ga., DensDeck Matrix 307 Premium EnergyGuard Polyiso Insulation,EnergyGuard GAF 2-Part, Ribbed Galvalume EverGuard TPO/#1121, Type B, Prime or Plate(Flat)may 1 per Asphalt Primer Ultra Polyiso Insulation LRF-M,LRF- 5-190. TPO 6-Square,TPO 3- -45.0* Grade 33 SECUROCK 4.0 ft2 Vapor Retarder: GAF SA (Optional)Min.0.25-inch DensDeck Prime or XF or steel Gypsum Fiber used)(no recessed Vapor Retarder,self- SECUROCK Gypsum-Fiber Roof Board or min.0.5- OB500 Square,W6181 Roof Board plate) adhering inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation 0.5-inch Note 2(Drill-Tec 3 in. One or more layers,base layer min.1-inch thick, Min.22 ga., DensDeck Primer:GAF SA Primer GAF 2-Part, Ribbed Galvalume optional subsequent layer(s)min.1.5-inch thick Type B, Prime or 1 per Vapor Retarder: GAF SA LRF-M,LRF- EverGuard TPO/TPO 6- 5-191. Grade 33 SECUROCK Plate(Flat)maybe 2.0 ft' Vapor Retarder,self- EnergyGuard Polyiso Insulation,EnergyGuard XF or Square -52.5 steel Gypsum Fiber used)(no recessed adhering Ultra Polyiso Insulation followed by Min.0.25- OB500 Roof Board plate) inch DensDeck Prime 0ensDh Note 2(Drill-Tec 3 in. One or more layers,base layer min.1-inch thick, Min.2 ga., DensDeck Primer:GAF SA Primer GAF 2-Part, Ribbed Galvalume optional subsequent layer(s)min.1.5-inch thick Type B, Prime or 1 per Vapor Retarder: GAF SA LRF-M,LRF- EverGuard TPO/#1121, 5-192. Plate(Flat)may be EnergyGuard Polyiso Insulation,EnergyGuard -67.5 Grade 33 SECUROCK 2.0 ft2 Vapor Retarder,self-adhering XF or TPO 3-Square,WB181 steel Gypsum Fiber used)(no recessed Ultra Polyiso Insulation followed by Min.0.25- OB500 Roof Board plate) inch DensDeck Prime 0.5-inch One or more layers,base layer min.1-inch thick, Note 2(Drill-Tec 3 in. Min.22 ga., DensDeck Primer:GAF SA Primer optional subsequent layer(s)min.1.5-inch thick GAF 2-Part, Ribbed Galvalume EverGuard , / Type B, Prime or 1 per Vapor Retarder: GAF SA EnergyGuard Polyiso Insulation,EnergyGuard LRF-M,LRF- 121, 5-193. Plate(Flat)may be TPO 6-Square,TPOO 3- 3- -67.5 Grade 33 SECUROCK used)(no recessed 2.0 ft2 Vapor Retarder,self- Ultra Polyiso Insulation followed by Min.0.25- XF or Square,W6181 steel Gypsum Fiber plate) adhering inch DensDeck Prime or SECUROCK Gypsum- OB500 Roof Board Fiber Roof Board EverGuard TPO/EverGuard TPO Quick Spray Adhesive or EverGuard TPO Quick Spray LV S0: Min.22 ga., Note 2(Drill-Tec 3 in. Grade 33 Min.0.5-inch Ribbed Galvalume Insulation:Min.1.5-inch EnergyGuard Polyiso 5-194. steel or min. SECUROCK Plate(Flat)maybe 1 per Liberty SBS Self-Adhering Insulation or EnergyGuard RA EverGuard TPO/TPO QSA 2,500 psi Gypsum-Fiber used)(no recessed 2.7 ft' Cap Sheet,self-adhering Coverboard:(Optional)Min.0.25-inch DensDeck OB500 or TPO QSA LVSO -45.0* structural Roof Board plate) Prime or SECUROCK Gypsum-Fiber Roof Board concrete 0.5-inch Primer:GAF SA Primer or Min.22 ga., DensDeck Note 2(Drill-Tec 3 in. Matrix 307 Premium Insulation:Min.1.5-inch EnergyGuard Polyiso GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Asphalt Primer Insulation or EnergyGuard RA LRF-M,LRF- EverGuard TPO/TPO QSA 5-195. Plate(Flat)may be -45.0* Grade 33 SECUROCK 4.0 ft' Vapor Retarder: GAF SA Coverboard:(Optional)Min.0.25-inch DensDeck XF or or TPO QSA LVSO steel Gypsum Fiber used)(no recessed Vapor Retarder,self- Prime or SECUROCK Gypsum-Fiber Roof Board OB500 Roof Board plate) adhering NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#31455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMD ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 43 of 156 *NEMO etc. TABLE 2D:STEEL DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF) SYSTEM TYPE B-2:MECHANICALLY ATTACHED THERMAL BARRIER,BONDED TEMP ROOF,BONDED TOP INSULATION,BONDED ROOF COVER Thermal Barrier Insulation Layer(s)System Deck Temp Roof Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (Notes 6,7,8) (Psf) 0.5-inch Note 2(Drill-Tec 3 in. Min.22 ga., DensDeck Primer:GAF SA Primer Insulation:Min.1.5-inch EnergyGuard Polyiso GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Vapor Retarder: GAF SA Insulation or EnergyGuard RA LRF-M,LRF- EverGuard TPO/TPO QSA 5-196. Plate(Flat)may be -67.5 Grade 33 SECUROCK 2.0 ft2 Vapor Retarder,self- Coverboard:Min.0.25-inch DensDeck Prime or XF or or TPO QSA LV50 steel Gypsum Fiber used)(no recessed adhering SECUROCK Gypsum-Fiber Roof Board OB500 Roof Board plate) EverGuard TPO/FastLayn TPO Adhesive: Min.22 ga., Min.0.5-inch Note 2 One or more layers,any combination,min.1.5- inch EnergyGuard Polyiso Insulation, Type B, SECUROCK (Drill-Tec3 in.Ribbed 1 per Liberty SBS Self-Adhering EverGuard TPO/FastLayn 5-197. Grade 33 Gypsum-Fiber Galvalume Plate 2.7 ft2 Cap Sheet,self-adhering EnergyGuard RA,min.0 DensDeck Prime OB500 TPO Adhesive -45.0* steel Roof Board (Flat)may be used) or SECUROCK Gypsum-Fiber Roof Board and min.0.5-inch EnergyGuard HD Polyiso Insulation Min.22 ga., Note 2 Two plies GAFGLAS Ply 4, Type B, Min.0.625-inch (Drill-Tec3 in.Ribbed 1 per hot asphalt EverGuard TPO/FastLayn 5-198. Grade 33 DensDeck Galvalume Plate 4.0 ft2 GAFGLAS Ply 4 M applied Min.1.5-inch EnergyGuard RA or OB500 TPO Adhesive -45.0* steel (Flat)may be used) in hot asphalt 0.5-inch Primer:GAF SA Primer or One or more layers,base layer min.1-inch thick, Min.22 ga., DensDeck Note 2 Matrix 307 Premium optional subsequent layer(s)min.1.5-inch thick GAF 2-Part, EnergyGuard Polyiso Insulation Type B, Prime or (Drill-Tec3 in.Ribbed 1 per Asphalt Primer LRF-M,LRF- EverGuard TPO/FastLayn 5-199. (Optional)Min.0.25-inch DensDeck Prime or -45.0* Grade 33 SECUROCK Galvalume Plate 4.0 ft2 Vapor Retarder: GAF SA SECXF or TPO Adhesive steel Gypsum Fiber (Flat)may be used) Vapor Retarder,self- inch En Gypsum-Fiber Roof Board or min.0.5- OBS00 Roof Board adhering inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation 0.5-inch One or more layers,base layer min.1-inch thick, Min.22 ga., DensDeck Note 2 Primer:GAF SA Primer optional subsequent layer(s)min.1.5-inch thick GAF 2-Part, Type B, Prime or EnergyGuard Polyiso Insulation yp (Drill-Tec3 in.Ribbed 1 per Vapor Retarder: GAF SA XF or LRF- EverGuard Adhesive /FastLayn 5-200. Min.0.25-inch DensDeck Prime or SECUROCK -60.0 Grade 33 SECUROCK Galvalume Plate 2.0 ft2 Vapor Retarder,self- XF or TPO Adhesive Gypsum-Fiber Roof Board or min. inch steel Gypsum Fiber (Flat)may be used) adhering or OB500 Roof Board EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation 0.5-inch Min.22 ga., DensDeck Note 2 Primer:GAF SA Primer GAF 2-Part, Type B, Prime or One or more layers,base layer min.1-inch thick, 5-201. yp (Drill-Tec3 in.Ribbed 1 per Vapor Retarder: GAF SA optional subsequent layer(s)min.1.5-inch thick LRF-M,LRF- EverGuard TPO/FastLayn _67.5 Grade 33 SECUROCK Galvalume Plate 2.0 ft2 Vapor Retarder,self- EnergyGuard Polyiso Insulation XF or TPO Adhesive steel Gypsum Fiber (Flat)may be used) adhering OB500 Roof Board EverGuard TPO Fleece-Back Membrane: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 44 of 156 *NEMO I etc. TABLE 21):STEEL DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF) SYSTEM TYPE B-2:MECHANICALLY ATTACHED THERMAL BARRIER,BONDED TEMP ROOF,BONDED BONDED ROOF Thermal Barrier Insulation Layer(s)System Deck Temp Roof Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (Notes 6,7,8) (psf) Min.22 ga., Note 2(Drill-Tec 3 in. Grade 33 Min. inch Ribbed Galvalume Min.1.5-inch EnergyGuard Polyiso Insulation, steel or min. SECUROCK 1 per Liberty SBS Self-Adhering EverGuard TPO Fleece- 5-202. 2,500 psi Gypsum-Fiber Plate(Flat)may be 2.7 ft2 Cap Sheet,self-adhering EnergyGuard Ultra,EnergyGuard RA, OB500 Back Membrane/WB181 -45.0* structural Roof Board used)(no recessed EnergyGuard RN,EnergyGuard RH concrete plate) Min.22 ga., Note 2(Drill-Tec 3 in. Min.1.5-inch EnergyGuard Polyiso Insulation, Grade 33 Min.0.5-inch Ribbed Galvalume EnergyGuard Ultra,EnergyGuard RA, steel or min. SECUROCK 1 per Liberty SBS Self-Adhering EverGuard TPO Fleece- 5-203. Plate(Flat)may be i EnergyGuard RN,EnergyGuard RH followed by OB500 -45.0* 2,500 psi Gypsum-Fiber used)(no recessed 2.7 ft Cap Sheet,self-adhering min.0.25-inch DensDeck Prime or SECUROCK Back Membrane/WB181 structural Roof Board plate) Gypsum-Fiber Roof Board concrete Min.2 ga.,3 Note 2(Drill-Tec 3 in. Grade 33 Min.0.5-inch Ribbed Galvalume Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece- 5-204. steel or min. SECUROCK Plate(Flat)may be 1 per Liberty SBS Self-Adhering EnergyGuard Ultra,EnergyGuard RA, OB500 Back Membrane/LRF-M -45.0* 2,500 psi Gypsum-Fiber used)(no recessed 2.7 ft Cap Sheet,self-adhering EnergyGuard RN,EnergyGuard RH or LRF-0,12-inch o.c. structural Roof Board plate) concrete Min.22 ga., Note 2(Drill-Tec 3 in. Min.1.5-inch EnergyGuard Polyiso Insulation, Grade 33 Min.0.5-inch Ribbed Galvalume EnergyGuard Ultra,EnergyGuard RA, EverGuard TPO Fleece- steel or min. SECUROCK 1 per Liberty SBS Self-Adhering 5-205. Plate(Flat)may be EnergyGuard RN,EnergyGuard RH followed by OB500 Back Membrane/LRF-M -45.0* 2,500 psi Gypsum-Fiber used)(no recessed 2.7 ft2 Cap Sheet,self-adhering min.0.25-inch SECUROCK Gypsum-Fiber Roof or LRF-O,12-inch o.c. structural Roof Board plate) Board concrete Min.22 ga., Note 2(Drill-Tec 3 in. Grade 33 Min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, p Gypsum Ribbed Galvalume EverGuard TPO Fleece- 2,500 min. SECUROCK 1 per Liberty SBS Self-Adhering EnergyGuard Ultra,EnergyGuard RA, 5-206. Plate(Flat)may be OB500 Back Membrane/LRF-O, -45.0* 2,500 psi Gypsum-Fiber used)(no recessed 2.7 ft2 Cap Sheet,self-adhering EnergyGuard RN,EnergyGuard RH followed by 12-inch o.c. structural Roof Board plate) min.0.25-inch DensDeck Prime concrete 0.5-inch Primer:GAF SA Primer or 1-inch thick EverGuard TPO Fleece- Min.22 ga., DensDeck Note 2(Drill-Tec 3 in. Matrix 307 Premium One or more layers,base layer min. , Back Membrane/WB181, Ribbed Galvalume optional subsequent layer(s)min.1.5-inch thick Type B, Prime or 1 per Asphalt Primer LRF-M or LRF-M(12-inch o.c.),LRF-O 5-207. Plate(Flat)may be EnergyGuard RN -45.0* Grade 33 SECUROCK used no recessed 4.0 ft2 Vapor Retarder: GAF SA OB500 (spatter,LRF GAF paPart steel Gypsum Fiber )( Vapor Retarder,self- (Optional)Min.um-inch DensDeck Prime or (spatter),LRF-XF(spatter) Roof Board plate) adhering SECUROCK Gypsum-Fiber Roof Board or OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 45 of 156 *NEMO I etc. TABLE 21):STEEL DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF) SYSTEM TYPE B-2:MECHANICALLY ATTACHED THERMAL BARRIER,BONDED TEMP ROOF,BONDED TOP INSULATION,BONDED ROOF COVER Thermal Barrier Insulation Layer(s)System Deck Temp Roof Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (Notes 6,7,8) (Psf) 0.5-inch Primer:GAF SA Primer or One or more layers,base layer min.1-inch thick, EverGuard TPO Fleece- Min.22 ga., DensDeck Note 2(Drill-Tec 3 in. Matrix 307 Premium optional subsequent layer(s)min.1.5-inch thick GAF 2-Part, Back Membrane/WB181, Type B, Prime or Ribbed Galvalume 1 per Asphalt Primer EnergyGuard Polyiso Insulation,EnergyGuard LRF-M,LRF- LRF-M(12-inch o.c.),LRF-O 5-208. Plate(Flat)may be -45.0* Grade 33 SECUROCK 4.0 ft2 Vapor Retarder: GAF SA Ultra Polyiso Insulation XF or (12-inch o.c.),GAF 2-Part steel Gypsum Fiber used)(no recessed Vapor Retarder,self- (Optional)Min.0.25-inch DensDeck Prime or OB500 (spatter),LRF-XF(spatter) Roof Board plate) adhering SECUROCK Gypsum-Fiber Roof Board or OB500(spatter) 0.5-inch Note 2(Drill-Tec 3 in. One or more layers,base layer min.1-inch thick, Min.22 ga., DensDeck Primer:GAF SA Primer GAF 2-Part, Ribbed Galvalume optional subsequent layer(s)min.1.5-inch thick Type B, Prime or 1 per Vapor Retarder: GAF SA LRF-M,LRF- EverGuard TPO Fleece- 5-209. Grade 33 SECUROCK Plate(Flat)may be 2.0 ft2 Vapor Retarder,self- EnergyGuard Polyiso Insulation,EnergyGuard XF or Back Membrane/WB181 adhering -52.5 steel Gypsum Fiber used)(no recessed Ultra Polyiso Insulation followed by Min.0.25- OB500 Roof Board plate) inch DensDeck Prime 0.5-inch Note 2(Drill-Tec 3 in. EverGuard TPO Fleece- Min.22 ga., DensDeck Ribbed Galvalume Primer:GAF SA Primer One or more layers,base layer min.1-inch thick, GAF 2-Part, Back Membrane/LRF-M Type B, Prime or 1 per Vapor Retarder: GAF SA optional subsequent layer(s)min.1.5-inch thick LRF-M,LRF- (12-inch o.c.),LRF-O(12- 5-210. Grade 33 SECUROCK Plate(Flat)may be 2.0 ft2 Vapor Retarder,self- EnergyGuard Polyiso Insulation,EnergyGuard XF or inch o.c.),GAF 2-Part -60.0 steel Gypsum Fiber used)(no recessed adheringUltra Polyiso Insulation OB500 (spatter),LRF-XF s(spatter) VP plate) y orr) ) Roof Board or OB500(spatter) 0.5-inch Note 2(Drill-Tec 3 in. One or more layers,base layer min.1-inch thick, Min.22 ga., DensDeck Ribbed Galvalume Primer:GAF SA Primer optional subsequent layer(s)min.1.5-inch thick GAF 2-Part, EverGuard TPO Fleece- Type B, Prime or 1 per Vapor Retarder: GAF SA LRF-M,LRF- Back Membrane/LRF-M 5-211. Grade 33 SECUROCK Plate(Flat)may be 2.0 ft2 Vapor Retarder,self- EnergyGuard Polyiso Insulation,EnergyGuard XF or (12-inch o.c.)or LRF-0(12- -60.0 steel Gypsum Fiber used)(no recessed Ultra Polyiso Insulation followed by Min.0.25- OB500 inch o.c.)adhering inch DensDeck Prime Roof Board plate) 0.5-inch EverGuard TPO Fleece- Min.22 ga., DensDeck Note 2(Drill-Tec 3 in. Primer:GAF SA Primer One or more layers,base layer min.1-inch thick, GAF 2-Part, Back Membrane/WB181, Ribbed Galvalume optional subsequent layer(s)min.1.5-inch thick Type B, Prime or 1 per Vapor Retarder: GAF SA LRF-M,LRF- LRF-M(4-inch o.c.),LRF-0 5-212. Grade 33 SECUROCK Plate(Flat)may be 2.0 ft2 Vapor Retarder,self- EnergyGuard Polyiso Insulation,EnergyGuard XF or (4-inch o.c.),GAF 2-Part -67.5 steel Gypsum Fiber used)(no recessed adhering Ultra Polyiso Insulation followed by Min.0.25- OB500 (spatter),LRF-XF(spatter) Roof Board plate) inch SECUROCK Gypsum-Fiber Roof Board or OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 46 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) EverGuard Freedom TPO: Min.22 ga.,Type B,Grade Note 2 5-213. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 6 parts per min.4 x 8 ft board with parts installed 36-inch o.c. 1 per EverGuard Freedom -30.0* structural concrete layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 5.3 ft2 TPO/self adhered board Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or One or more layers,any Min.0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard Freedom 5-214. 33 steel or min.2,500 psi combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 4.0 ft2 TPO/self adhered -30.0* structural concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 el ga.,Type B,Grade 5-215. 33 steel ( Note 2 Optional)One or more Min.1.5-inch EnergyGuard Polyiso 1 per EverGuard Freedom -37.5* structurall min.2,500 psi concrete layers,any combination Insulation,EnergyGuard Ultra 2.7 ft2 TPO/self adhered Min.22 ga.,Type B,Grade (Optional)One or more Min.2-inch EnergyGuard RA, 1 per EverGuard Freedom 5-216. 33 steel or min.2,500 psi layers,any combination EnergyGuard RN,or EnergyGuard Ultra Note 2 3.2 ft' TPO/self adhered -45.0* structural concrete Min.22 ga.,Type B,Grade Min.0.5-inch EnergyGuard RH HD 5-217. 33 steel or min.2,500 psi (Optional)One or more Polyiso Insulation,EnergyGuard HD Note 2 1 per EverGuard Freedom _45.0* structural concrete layers,any combination Polyiso Insulation,EnergyGuard HD 2.0 ft2 TPO/self adhered Plus Polyiso Insulation Min.22 ga.,Type B,Grade 5-218. 33 steel or min.2,500 psi (Optional)One or more Min.1.5-inch EnergyGuard Polyiso Note 2 1 per EverGuard Freedom _45.0* structural concrete layers,any combination Insulation,EnergyGuard Ultra 2.0 ft TPO/self adhered Min.22 ga.,Type B,Grade Note 2 5-219. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 8 parts per min.4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard Freedom -45.0* structural concrete layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 4.0 ft TPO/self adhered board Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or 5-220. 33 steel or min.2,500 psi One or more layers,any Min.0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard Freedom -45.0* structural concrete combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 3.2 ft TPO/self adhered Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or 5-221. 33 steel or min.2,500 psi One or more layers,any Min.0.375-inch SECUROCK Gypsum- Drill-Tec AccuTmc Flat Plates or with Drill-Tec ASAP 35 or Drill- 1 per EverGuard Freedom _45.0* combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft TPO/self adhered structural concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade (Optional)One or more Min.2-inch EnergyGuard RA, 1 per EverGuard Freedom 5-222. 33 steel or min.2,500 psi layers,any combination EnergyGuard RN,or EnergyGuard Ultra Note 2 1.3 ft2 TPO/self adhered -52.5 structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 47 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade (Optional)One or more Min.2-inch EnergyGuard RA, 1 per EverGuard Freedom 5-223. 33 steel or min.2,500 psi Note 2(#14 only) -52.5 structural concrete layers,any combination EnergyGuard RN,or EnergyGuard Ultra 2.0 ft2 TPO/self adhered Min.22 ga.,Type B,Grade Drill-Tec#12(steel only)or Drill-Tec#14 Fastener with Drill- 5-224. 33 steel or min.2,500 psi One or more layers,any Min.0.25-inch DensDeck Prime Tec 3 in Ribbed Galvalume Plate(Flat)or Drill-Tec#12 DP 1 per EverGuard Freedom -60.0 combination,min.1-inch Fastener(steel only),Drill-Tec#14 HD Fasteneror Drill-Tec 1.45 ft' TPO/self adhered structural concrete #15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.20 ga.,Type B,Grade Drill-Tec#12(steel only)or Drill-Tec#14 Fastener with Drill- 5-225. 33 steel One or more layers,any Min.0.25-inch SECUROCK Gypsum- Tec 3 in Ribbed Galvalume Plate(Flat),Drill-Tec#12 DP 1 per EverGuard Freedom -60.0 structurall min.2,500 psi concrete combination,min.1-inch Fiber Roof Board Fastener(steel only),Drill-Tec#ia HD Fasteneror Drill-Tec 1.3 ft2 TPO/self adhered #15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.20 ga.,Type B,Grade Drill-Tec#12(steel only)or Drill-Tec#14 Fastener with Drill- 5-226. 33 steel or min.2,500 psi One or more layers,any Min.0.375-inch SECUROCK Gypsum- Tec 3 in Ribbed Galvalume Plate(Flat),Drill-Tec#12 DP 1 per EverGuard Freedom -75.0 combination,min.1-inch Fiber Roof Board Fastener(steel only),Drill-Tec#14 HD Fasteneror Drill-Tec 1.45 ft' TPO/self adhered structural concrete #15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate EverGuard TPO/EverGuard TPO#1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min.22 ga.,Type B,Grade (Optional)One or more Min.1.5-inch EnergyGuard RA, 1 per EverGuard TPO/ 5-227. 33 steel or min.2,500 psi layers,any combination EnergyGuard RN,EnergyGuard PH Note 2 3.2 ft2 #1121,TPO 3-Square -30.0* structural concrete Min.22 ga.,Type B,Grade Note 2 5-228. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 6 parts per min.4 x 8 ft board with parts installed 36-inch c.c. 1 per EverGuard TPO/ -30.0* structural concrete layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 5.3 ft2 #1121,TPO 3-Square board Drill-Tec#12(steel only)or#14with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or 5-229. 33 steel or min.2,500 psi One or more layers,any Min.0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO/ -30.0* combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 4.0 ft2 #1121,TPO 3-Square structural concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 5-230. 33 steel or min.2,500 psi (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 per EverGuard TPO/ -37.5* structural concrete layers,any combination EnergyGuard RA,EnergyGuard RN, 2.7 ft' #1121,TPO 3-Square EnergyGuard RH Min.22 ga.,Type B,Grade 5-231. 33 steel or min.2,500 psi (Optional)One or more Min.0.25-inch SECUROCK Gypsum- Note 2 1 per EverGuard TPO/ -37.5* structural concrete layers,any combination Fiber Roof Board 2.7 ft' #1121,TPO 3-Square Min.22 ga.,Type B,Grade 5-232. 33 steel or min.2,500 psi (Optional)One more Min.0.25-inch DensDeck Prime Note 2(Drill-Tec 3"Standard Steel Plate only) 1 per EverGuard / -45.0* structural concrete layers,any combination 2.7 ft' #1121,TPO 3-Square Min.22 ga.,Type B,Grade (Optional)One or more Note 2(Drill-Tec3"Steel Plate or Drill-Tec 3"Flat Steel 1 per EverGuard TPO/ 5-233. 33 steel or min.2,500 psi layers,any combination Min.0.25-inch DensDeck Prime Plate only) 2.13 ft2 #1121,TPO 3-Square -45.0* structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 48 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/ 5-234. 33 steel or min.2,500 psi layers,any combination Min.0.25-inch DensDeck Prime Note 2 2.0 ft2 #1121,TPO 3-Square -45.O* structural concrete Min.22 ga.,Type B,Grade (Optional)One or more Min.0.5-inch DensDeck or DensDeck 1 per EverGuard TPO/ 5-235. 33 steel or min.2,500 psi layers,any combination Prime Note 2 3.2 ft2 #1121,TPO 3-Square -45.0* structural concrete Min.22 ga.,Type B,Grade IPO 5-236. 33 steel or min.2,500 psi (Optional)One bi more Min.Deck Pinch DensDeck or Note 2 .per EverGuard 3-S/ -45.0* structural concrete layers,any combination DensDeck Prime 4.0 ft2 #1121,TPO 3-Square Min.22 ga.,Type B,Grade PO 5-237. 33 steel or min.2,500 psi (Optional)One bi more Min.Roof SECUROCK Gypsum- Note 2 1 per EverGuard 3-S/ -45.0* structural concrete layers,any combination Fiber Roof Board 2.0 ft2 #1121,TPO 3-Square Min.22 ga.,Type B,Grade 5-238. 33 steel or min.2,500 psi (Optional)One or more Min.0.625-inch SECUROCK Gypsum- Note 2 1 pe z EverGuard TPO/ -45.0* structural concrete layers,any combination Fiber Roof Board 4.0 ft #1121,TPO 3-Square Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or 5-239. 33 steel or min.2,500 psi One or more layers,any Min.0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO/ -45.0* structural concrete combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 3.2 ft2 #1121,TPO 3-Square Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Drill-Tec#12(steel only)or#14with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or 5-240. 33 steel or min.2,500 psi One or more layers,any Min.0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO/ -45.0* structural concrete combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 4.0 ft2 #1121,TPO 3-Square Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/ 5-241. 33 steel or min.2,500 psi layers,any combination Min.7/16-inch OSB Note 2 4.0 ft2 #1121,TPO 3-Square -45.0* structural concrete Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/ 5-242. 33 steel or min.2,500 psi layers,any combination Min.7/16-inch OSB Note 2 2.0 ft2 #1121,TPO 3-Square -45.0* structural concrete Min.22 ga.,Type B,Grade One or more layers,any Min.0.5-inch EnergyGuard RH HD 5-243. 33 steel or min.2,500 psi combination,min.1.5- Polyiso Insulation,EnergyGuard HD Note 2 1 per EverGuard TPO/ -45.0* structural concrete inch Polyiso Insulation,EnergyGuard HD 2.0 ft2 #1121,TPO 3-Square Plus Polyiso Insulation Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 5-244. 33 steel or min.2,500 psi (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 per EverGuard TPO/ -45.0* structural concrete layers,any combination EnergyGuard RA,EnergyGuard RN, 2.0 ft2 #1121,TPO 3-Square EnergyGuard RH or EnergyGuard Ultra NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 49 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Note 2 a 1 per Min.22 ga.,Type B,Grade o 0 0 0 0 2.3 ft2 S-245. 33 steel or min.2,500 psi (Optional)One or more Min.2.5-inch EnergyGuard Polyiso - (14 EverGuard TPO/ -45.0 structural concrete layers,any combination Insulation,EnergyGuard Ultra 0 0 0 o parts #1121,TPO 3-Square per 4x8 0 0 0 0 o ft board) x F Min.22 ga.,Type B,Grade Note 2 (Optional)One or more Min.2-inch EnergyGuard Polyiso 8 parts per min.4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard TPO/ 5-246. t steel l min.2,500 psi layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 4.0 ft2 #1121,TPO 3-Square -45.0* structural concrete board Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard RA, / S-247. 33 steel or min.2,500 psi layers(Optional)One or more any combination EnergyGuard RN,EnergyGuard RH or Note 2 1 1 ft2 #1121,per EverGuard and TP IP O Square -45.0* , structural concrete EnergyGuard Ultra Min.22ga.,Type B,Grade One or more layers,any Min.0.25-inch DensDeck Prime or 1 per EverGuard TPO/ 5-248. 33 steelel min.2,500 psi combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1.8 ft2 #1121,TPO 3-Square -52.5 structural concrete Min.22 ga.,Type B,Grade S-249. 33 steel or min.2,500 psi (Optional)One bi more Min. tiinch EnergyGuard Polyiso Note 2 1 per EverGuard 3-S/ -60.0 structural concrete layers,any combination Insulation 1.8 ft2 #1121,TPO 3-Square Note 2 Min.22 ga.,Type B,Grade o 5-250. 33 steel or min.2,500 psi (Optional)One or more Min.2.5-inch EnergyGuard Polyiso 1 per EverGuard TPO/ -60.0 structural concrete layers,any combination Insulation ® ® ®1 2.0 ft2 #1121,TPO 3-Square ) Min.22 ga.,Type B,Grade (Optional)One more 1 perEverGuard S-251. 33 steel or min.2,500 psi Min.2-inch EnergyGuard RH Note 2 3-S/ -67.5 structural concrete layers,any combination 1.8 ft2 #1121,TPO 3-Square Min.20 ga.,Type B,Grade 5-252. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso Drill-Tec#12(steel only)or Drill-Tec#14 Fastener with 1 per EverGuard TPO/ -67.5 structural concrete layers,any combination Insulation or EnergyGuard RH Drill-Tec 3 in Ribbed Galvalume Plate 1.6 ft2 #1121,TPO 3-Square Min.22 ga.,Type B,Grade One or more layers,any Min.0.375-inch SECUROCK Gypsum- 1 per EverGuard TPO/ S-253. 33 steel or min.2,500 psi combination,min.1-inch Fiber Roof Board Note 2 1.3 ft2 #1121,TPO 3-Square -67.5 structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 50 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade One or more layers,any Min.0.5-inch Structodek High Density 1 per EverGuard TPO/ 5-254. 33 steel or min.2,500 psi combination,min.1.5- Roof Fiberboard Note 2 1.0 ft2 #1121,TPO 3-Square -67.5 structural concrete inch Min.22 ga.,Type B,Grade One or more layers,any Min.0.5-inch SECUROCK Gypsum-Fiber 1 per EverGuard TPO/ 5-255. 33 steel or min.2,500 psi combination,min.1.5- Roof Board Note 2 1.0 W #1121,TPO 3-Square 97.5 structural concrete inch Min.22 ga.,Type B,Grade One or more layers,any Drill-Tec#12(steel only),#14 or XHD with Drill-Tec 3 in. Ribbed Galvalume Plates(Flat)or Drill-Tec#12 DP Fastener 1 per EverGuard TPO/ 5-256. 80 steel min. psi combination,min.1.5- Min.0.5-inch DensDeck Prime (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD 1.0 ft2 #1121 -127.5 structurall concreteto inch Fastener(steel only)with Drill-Tec 3"Flat Steel Plate EverGuard TPO/EverGuard WB181 Bonding Adhesive: Min.22 ga.,Type B,Grade 5-257. 33 steel or min.2,500 psi (Optional)One more Min.1.5-inch EnergyGuard Note 2 per EverGuard TPO/ -30.0* structural concrete layers,any combination EnergyGuard RN,EnergyGuardand RH 3.2 ft2 WB181 Min.22 ga.,Type B,Grade Note 2 5-258. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 6 parts per min.4 x 8 ft board with parts installed 36-inch o.c. 1 per EverGuard TPO/ -30.0* structural concrete layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 5.3 ft2 WB181 board Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or One or more layers,any Min.0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO/ 5-259. 33 steel or min.2,500 psi combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft2 WB181 -30.0* structural concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 5-260. 33 steel or min.2,500 psi (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 per EverGuard TPO/ -37.5* structural concrete layers,any combination EnergyGuard RA,EnergyGuard RN, 2.7 ft2 WB181 EnergyGuard RH Min.22 ga.,Type B,Grade 5-261. 33 steel or min.2,500 psi (Optional)One o.more Min.0.25-inch DensDeck Prime Note 2 1 per i EverGuard TPO/ -45.0* structural concrete layers,any combination 2.0ft WB181 Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/ 5-262. 33 steel or min.2,500 psi layers,any combination Min.0.5-inch DensDeck Prime Note 2 3.2 ft2 WB181 -45.0* structural concrete Min.22 ga.,Type B,Grade Drill-Tec#12(steel only)or#14 with Drill-Tec 3 in.Ribbed 5-263. 33 steel or min.2,500 psi (Optional)One or more Min.0.5-inch DensDeck Prime Galvalume Plates(Flat)or Drill-Tec#12 DP Fastener(steel 1 per EverGuard TPO/ -45.0* structural concrete layers,any combination only),Drill-Tec#14 HD Fasteneror Drill-Tec#15 EHD Fastener 4.0 ft2 WB181 (steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/ 5-264. 33 steel or min.2,500 psi layers,any combination Min.0.625-inch DensDeck Prime Note 2 4.0 ft2 WB181 -45.0* structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 51 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade (Optional)One or more Min.0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO/ 5-265. 33 steel or min.2,500 psi layers,any combination Fiber Roof Board Note 2 2.0 ft2 WB181 -45.0* structural concrete Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or 5-266. 33 steel or min.2,500 psi One or more layers,any Min.0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO/ _45.0* combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 3.2 ft WB181 structural concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Drill-Tec#12(steel only)or#14with Drill-Tec 3"Standard Min.22 ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or 5-267. 33 steel or min.2,500 psi One or more layers,any Min.0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO/ _45.0* structural concrete combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft2WB181 Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.0.5-inch EnergyGuard RH HD Min.22 ga.,Type B,Grade One or more layers,any 5-268. 33 steel ga min.2,500 psi combination,min. an Polyiso Insulation,EnergyGuard HD Note 2 1 per i EverGuard TPO/ _45.0* structural concrete inch Polyiso Insulation,EnergyGuard HD 2.0ft WB181 Plus Polyiso Insulation Min.22 ga.,Type B,Grade Min.1.5-inch EnergyGuard Polyiso 5-269. 33 steel or min.2,500 psi (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 pe EverGuard TPO/ -45.0* structural concrete layers,any combination EnergyGuard RA,EnergyGuard RN or 2.0 ft2WB181 EnergyGuard RH Min.22 ga.,Type B,Grade Note 2 5-270. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 8 parts per min.4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard TPO/ _45.0* structural concrete layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges ofthe 4.0 ft2 WB181 board Min.22 ga.,Type B,Grade 5-271. 33 steel or min.2,500 psi (Optional)One more Min.2-inch EnergyGuard RA, Note 2 per 2 EverGuard TPO/ _45.0* structural concrete layers,any combination EnergyGuard RN or EnergyGuard RH 4..0 ft WB181 Min.22 ga.,Type B,Grade One or more layers,any 1 per EverGuard TPO/ 5-272. 33 steel or min.2,500 psi combination,min.1.5- Min.0.25-inch DensDeck Prime Note 2 1.45 ft2 WB181 -52.5 structural concrete inch Min.22 ga.,Type B,Grade One or more layers,any Min.0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO/ 5-273. 33 steel min. psi combination,min.1-inch Fiber Roof Board Note 2 1.8 ft2 WB181 -52.5 structurall concretteo Min.22 ga.,Type B,Grade One or more layers,any Min.0.375-inch SECUROCK Gypsum- 1 per EverGuard TPO/ 5-274. t ructura steel or min.concrete t psi combination,min.1-inch Fiber Roof Board Note 2 1.3 ft2 WB181 -67.5 s stl e Min.22 ga.,Type B,Grade One or more layers,any in.0.5-inch Structodek High Density 1 per EverGuard TPO/ 5-275. 33 steel or min.2,500 psi combination,min.1.5- Fiberboard Roof Insulation,Fiber Base Note 2 2 -67.5 structural concrete inch HDl or Fiber Base HD6 1.0 ft WB181 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-RA Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 52 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade One or more layers,any Drill-Tec#12(steel only),#14 or XHD with Drill-Tec 3 in. 5-276. 33 steel or min.2,500 psi combination,min.1.5- Min.0.5-inch DensDeck Prime Ribbed Galvalume Plates(Flat)or Drill-Tec#12 DP Fastener 1 per EverGuard TPO/ -75.0 Structural concrete Inch (steel only),Drill-Tec#14 HD Fasteneror Drill-Tec#15 EHD 1.6 ft2 WB181 Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade One or more layers,any Drill-Tec#12(steel only),#14 or XHD with Drill-Tec 3 in. / 5-277. 33 steel or min.2,500 psi combination,min.1.5- Min.0.5-inch DensDeck Prime Ribbed Galvalume Plates(Flat)or Drill-Tec#12 DP Fastener 1 per EverGuard TPO(steel only),Drill-Tec#14 HD Fasteneror Drill-Tec#15 EHD 1.0 ft2 WB181 82.5 structural concrete inch Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade One or more layers,any Drill-Tec#12(steel only),#14 or XHD with Drill-Tec 3 in. / 5-278. 80 steel or min.2,500 psi combination,min.1.5- Min.0.5-inch DensDeck Prime Ribbed Galvalume Plates(Flat)or Drill-Tec#12 DP Fastener 1 per EverGuard TPO(steel only),Drill-Tec#14 HD Fasteneror Drill-Tec#15 EHD 1.0 ft' WB181 -127.5 structural concrete Inch Fastener(steel only)with Drill-Tec 3"Flat Steel Plate EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min.22 ga.,Type B,Grade (Optional)One or more Min.1.5-inch EnergyGuard RA, 1 per EverGuard TPO/TPO 5-279. 33 steel or min.2,500 psi layers,any combination EnergyGuard RN,EnergyGuard RH Note 2 3.2 ft2 6-Square,TPO 3- -30.0* structural concrete Square Min.22 ga.,Type B,Grade Note 2 EverGuard TPO/TPO 5-280. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 6 parts per min.4 x 8 ft board with parts installed 36-inch o.c. 1 per 6-Square,TPO 3- -30.0* layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 5.3 ft structural concrete board Square Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or Min.22 ga.,Type B,Grade EverGuard TPO/TPO One or more layers,any Min.0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 5-281. 33 steel or min.2,500 psi combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 4.0 ft2 6-Square,TPO 3- -30.0* structural concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Square Steel Plate Min.1.5-inch EnergyGuard Polyiso Min.22 ga.,Type B,Grade EverGuard TPO/TPO 5-282. 33 steel or min.2,500 psi (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 per 6-Square,TPO 3- -37.5* structural concrete layers,any combination EnergyGuard RA,EnergyGuard RN, 2.7 ft2 Square EnergyGuard RH Min.22 ga.,Type B,Grade (Optional)One or more Min.0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO/TPO 5-283. 33 steel or min.2,500 psi layers,any combination Fiber Roof Board Note 2 2.7 ft2 6-Square,TPO 3- -37.5* structural concrete Square Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/TPO 5-284. 33 steel or min.2,500 psi layers,any combination Min.0.25-inch DensDeck Prime Note 2(Drill-Tec 3"Standard Steel Plate only) 2.7 ft' 6-Square,TPO 3- -45.0* structural concrete Square Min.22 ga.,Type B,Grade TPO (Optional)One or more Note 2(Drill-Tec 3"Steel Plate or Drill-Tec 3"Flat Steel 1 per EverGuard TPO- 5-285. 33 steel or min.2,500 psi layers,any combination Min.0.25-inch DensDeck Prime Plate only) 2.13 ft2 6-Square,TPO 3- -45.0* structural concrete Square Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/TPO 5-286. 33 steel or min.2,500 psi layers,any combination Min.0.25-inch DensDeck Prime Note 2 2.0 ft' 6-Square,TPO 3- structural concrete Square NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 53 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/TPO 5-287. 33 steel or min.2,500 psi layers,any combination Min.0.5-inch DensDeck Prime Note 2 3 2 ft2 6-Square,TPO 3- -45.0* structural concrete Square Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/TPO 5-288. 33 steel or min.2,500 psi layers,any combination Min.0.625-inch DensDeck Prime Note 2 4.0 ft2 6-Square,TPO 3- -45.0* structural concrete Square Min.22 ga.,Type B,Grade (Optional)One or more Min.0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO/TPO 5-289. 33 steel or min.2,500 psi layers,any combination Fiber Roof Board Note 2 2.0 ft2 6-Square,TPO 3- -45.0* structural concrete Square Min.22 ga.,Type B,Grade (Optional)One or more Min.0.625-inch SECUROCK Gypsum- 1 per EverGuard TPO/TPO 5-290. 33 steel min.2,500 psi layers,any combination Fiber Roof Board Note 2 4.0 ft2 6-Square,TPO 3- -45.0* structurall concrete Square Min.22 ga.,Type B,Grade (ayers,Optional)One or more 1 1 EverGuard TPO/TPO per 5-291. 33 steel or min.2,500 psi l any combination Min.0.25-inch DensDeck Prime Note 2 6-Square,TPO 3- -45.0 structural concrete .45 ft2 Square Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min. ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or TPO EverGuard TPO 5-292. 33 steeell or min.2,500 psi One or more layers,any Min.0.25-inch SECUROCK Gypsum- Drill-Tec Accu7rac Flat Plates or with Drill-Tec ASAP 35 or Drill- 1 per 6-Square,TPO 3-- -45.0* Structural concrete combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 3.2 ft2 Square Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Drill-Tec#12(steel only)or#14with Drill-Tec 3"Standard Min. ga.,Type B,Grade Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or TPO EverGuard TPO 5-293. 33 steeell or min.2,500 psi One or more layers,any Min.0.375-inch SECUROCK Gypsum- Drill-Tec Accu7rac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 6-Square,TPO 3-- -45.0* Structural concrete combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 4.0 ft2 Square Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade One or more layers,any Min.0.5-inch EnergyGuard RH HD EverGuard TPO/TPO 5-294. 33 steel or min.2,500 psi combination,min.1.5- Polyiso Insulation,EnergyGuard HD Note 2 1 per i 6-Square,TPO 3- -45.0* structural concrete inch Polyiso Insulation,EnergyGuard HD 2.0 ft Square Plus Polyiso Insulation Min.22 .,Type B,Grade Min.1.5-inch EnergyGuard Polyiso PO/TPO EverGuard T ga 5-295. 33 steel or min.2,500 psi (Optional)One more Insulation,EnergyGuard Ultra, Note 2 .per 6-Square,TPO 3- -45.0* structural concrete layers,any combination EnergyGuard RA,EnergyGuard 20 ft2 Square EnergyGuard RH or EnergyGuardd U Ultra NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 54 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Note 2 a 1 per Min.22 ga.,Type B,Grade o 0 0 0 0 2.3 ft' EverGuard TPO/TPO S-296. 33 steel or min.2,500 psi (Optional)One or more Min.2.5-inch EnergyGuard Polyiso - (14 6-Square,TPO 3- -45.0 structural concrete layers,any combination Insulation,EnergyGuard Ultra _ 0 0 0 o parts per 4x8 Square 0 0 0 0 o ft board) x F Min.22 ga.,Type B,Grade Note 2 EverGuard TPO/TPO S-297. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 8 parts per min.4 x 8 ft board with parts installed 24-inch o.c. 1 per i 6-Square,TPO 3- -45.0* structural concrete layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 4.0ft Square board Min.22 ga.,Type B,Grade (Optional)One or more Min.2-inch EnergyGuard RA, 1 p EverGuard TPO/TPO S-298. 33 steel or min.2,500 psi layers any combination EnergyGuard RN,EnergyGuard RH or Note 2 4 0 per erft2 6-Square,TPO 3- -45.0* , structural concrete EnergyGuard Ultra Square Min.22 ga.,Type B,Grade EverGuard TPO/TPO S-299. 33 steel or min.2,500 psi One or more layers,any Min.0.25-inch SECUROCK Gypsum- Note 2 1 per i 6-Square,TPO 3- -52.5 structural concrete combination,min.1-inch Fiber Roof Board 1.8 ft Square Min.22 ga.,Type B,Grade EverGuard TPO/TPO S-300. 33 steel or min.2,500 psi (Optional)One more Min inch EnergyGuard Polyiso Note 2 1 per 6-Square,TPO 3- -60.0 structural concrete layers,any combination Insulation atition 1.8ft2 Square Note 2 Min.22 ga.,Type B,Grade o ® �c EverGuard TPO/TPO S-301. 33 steel or min.2,500 psi (Optional)One or more Min.2.5-inch EnergyGuard Polyiso 1 per 6-Square,TPO 3- -60.0 structural concrete layers,any combination Insulation ® ® ®1 2.0ft2 Square ) Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/TPO S-302. 33 steel or min.2,500 psi layers,any combination Min.2-inch EnergyGuard RH Note 2 1.8 ft' 6-Square,TPO 3- -67.5 structural concrete Square Min.20 ga.,Type B,Grade EverGuard TPO/TPO 5-303. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso Drill-Tec#12(steel only)or Drill-Tec#14 Fastener with 1 per 6-Square,TPO 3- -67.5 structural concrete layers,any combination Insulation,EnergyGuard Ultra Drill-Tec 3 in Ribbed Galvalume Plate 1.6 ft2 Square Min.22 ga.,Type B,Grade EverGuard TPO/TPO S-304. 33 steel or min.2,500 psi One or more layers,any Min.Roof inch SECUROCK Gypsum- Note 2 1 per 6-Square,TPO 3- -67.5 structural concrete combination,min.1-inch Fiber Roof Board 1.3 ft2 Square NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 55 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade One or more layers,any EverGuard TPO/TPO Fib Roof Fib 5-305. 33 steel or min.2,500 psi combination,min.1.5- Min. inch Structodek High Density Note 2 1 per 6-Square,TPO 3- -67.5 structural concrete inch Fiberboard 1.0 ft2 Square Min.22 ga.,Type B,Grade One or more layers,any Drill-Tec#12(steel only),#14 or XHD with Drill-Tec 3 in. 5-306. 33 steel or min.2,500 psi combination,min.1.5- Min.0.5-inch DensDeck Prime Ribbed Galvalume Plates(Flat)or Drill-Tec#12 DP Fastener 1 per EverGuard TPO/TPO -75.0 (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD 1.6 ft2 3-Square structural concrete inch Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B,Grade One or more layers,any Drill-Tec#12(steel only),#14 or XHD with Drill-Tec 3 in. 5-307. 80 steel or min.2,500 psi combination,min.1.5- Min.0.5-inch DensDeck Prime Ribbed Galvalume Plates(Flat)or Drill-Tec#12 DP Fastener 1 per EverGuard TPO/TPO -127.5 structural concrete inch (steel only),Drill-Tec#14 HD Fasteneror Drill-Tec#15 EHD 1.0 ft2 3-Square Fastener(steel only)with Drill-Tec 3"Flat Steel Plate EverGuard TPO/EverGuard TPO Quick Spray Adhesive or EverGuard TPO Quick Spray Adhesive LV 50: Min.22 ga.,Type B,Grade One or more layers,any Min.0.25-inch DensDeck Prime or 1 per EverGuard TPO/TPO 5-308. 33 steel or min.2,500 psi combination,min.1-inch SECUROCK Gypsum-Fibrer Roof Board Note 2 1.8 ft2 QSA or TPO QSA LV50 -52.5 structural concrete Min.22 ga.,Type B,Grade Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener or 5-309. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard RA Drill-Tec XHD Fastener(steel only)with Drill-Tec 3"Standard 1 per EverGuard TPO/TPO -60.0 structural concrete layers,any combination Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat 1.45 ft2 QSA LV50 Plate Min.22 ga.,Type B,Grade Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener or 5-310. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard RA Drill-Tec XHD Fastener(steel only)with Drill-Tec 3"Standard 1 per EverGuard TPO/TPO -75.0 structural concrete layers,any combination Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat 1.45 ft2 QSA Plate Min.22 ga.,Type B,Grade Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener or 5-311. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso Drill-Tec XHD Fastener(steel only)with Drill-Tec 3"Standard 1 per EverGuard TPO/TPO 82 5 structural Concrete layers,any combination Insulation Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat 1.45 ft2 QSA or TPO QSA LV50 Plate Min.22 ga.,Type B,Grade (Optional)One or more Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener or 1 per EverGuard TPO/TPO 5-312. 33 steel or min.2,500 psi layers,any combination, Min.0.25-inch DensDeck Prime Drill-Tec XHD Fastener(steel only)with Drill-Tec 3"Standard 1.45 ft2 QSA or TPO QSA LV50 82.5 structural concrete min.2-inch Steel Plate or Drill-Tec AccuTrac Flat Plate Min.22 ga.,Type B,Grade (Optional)One or more Min.0.25-inch SECUROCK Gypsum- Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener or 1 per EverGuard TPO/TPO 5-313. 33 steel or min.2,500 psi layers,any combination, Drill-Tec XHD Fastener(steel only)with Drill-Tec AccuTrac Flat -82.5 structural concrete min.2-inch Fiber Roof Board Plate 1.45 ft2 QSA or TPO QSA LV50 EverGuard TPO/FastLayn TPO Adhesive: Min.22 ga.,Type B,Grade Note 2 (Optional)One or more Min.2-inch EnergyGuard Polyiso 6 parts per min.4 x 8 ft board with parts installed 36-inch o.c. 1 per EverGuard TPO/ 5-314. 33 steel or min.2,500 psi layers,any combination Insulation in two parallel rows,12 inches from the 8 ft edges of the 5.3 ft2 FastLayn TPO Adhesive 30.0* structural concrete board Min.22 ga.,Type B,Grade One or more layers,any Min.0.25-inch DensDeck Prime or 1 per EverGuard TPO/ 5-315. 33 steel or min.2,500 psi combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Note 2 4.0 ft2 FastLayn TPO Adhesive �i�] structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 56 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B,Grade 5-316. 33 steel or min.2,500 psi (Optional)One or more Min.1.5-inch EnergyGuard RA Note 2 1 per EverGuard TPO/ -30.0* structural concrete layers,any combination 3.2 ft2 FastLayn TPO Adhesive Min.22 ga.,Type B,Grade One or more layers,any Min.0.5-inch EnergyGuard HD Polyiso 1 per EverGuard TPO/ 5-317. 33 steel or min.2,500 psi combination Insulation Note 2 3.2 ft2 FastLayn TPO Adhesive -30.0* structural concrete Min.22 ga.,Type B,Grade 5-318. 33 steel or min.2,500 psi (Optional)One or more Min.1.5-inch EnergyGuard Polyiso Note 2 1 per EverGuard TPO ft / -37.5* structural concrete layers,any combination Insulation,EnergyGuard RA 2.7 ' FastLayn TPO Adhesive Min.22 ga.,Type B,Grade 5-319. 33 steel or min.2,500 psi One or more layers,any Min inch EnergyGuard HD Polyiso Note 2 1 per EverGuard / -37.5* structural concrete combination Insulation atiodo n 2.7 ft2 FastLayn TPOO A Adhesive Min.22 ga.,Type B,Grade 5-320. 33 steel or min.2,500 psi (Optional)One or more Min.0.25-inch SECUROCK Gypsum- Note 2 1 pe EverGuard TPO/ -37.5* structural concrete layers,any combination Fiber Roof Board 2.7 ft2 FastLayn TPO Adhesive Min.22 ga.,Type B,Grade (Optional)One or more Min.2-inch EnergyGuard RA or Min. 1 per EverGuard TPO/ 5-321. 33 steel or min.2,500 psi layers,any combination 0.625-inch DensDeck Prime or Note 2 4.0 ft2 FastLayn TPO Adhesive -45.0* structural concrete SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/ 5-322. 33 steel or min.2,500 psi layers,any combination Min.0.5-inch DensDeck Prime Note 2 3.2 ft2 FastLayn TPO Adhesive -45.0* structural concrete 1 per 2.3 ft' Min.22 ga.,Type B,Grade (14 PO 5-323. 33 steel or min.2,500 psi (Optional)One bi more Min. do inch EnergyGuard Polyiso Note 2 parts EverGuard O A/ -45.0 structural concrete layers,any combination Insulation per 4x8 FastLayn TPO Adhesive ft board) Min.22 ga.,Type B,Grade Note 2 5-324. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso 8 parts per min.4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard TPO/ -45.0* layers,any combination Insulation in two parallel rows,12 inches from the 8 ft edges of the 4.0 ft' FastLayn TPO Adhesive structural concrete board Min.22 ga.,Type B,Grade (Optional)One or more 1 per EverGuard TPO/ 5-325. 33 steel or min.2,500 psi layers,any combination Min.0.25-inch DensDeck Prime Note 2(Drill-Tec 3"Standard Steel Plate only) 2 7 ft' FastLayn TPO Adhesive -45.0* structural concrete Min.22 ga.,Type B,Grade (Optional)One or more Note 2(Drill-Tec3"Steel Plate,Drill-Tec3"Flat Steel 1 per EverGuard TPO/ 5-326. 33 steel l min.2,500 psi layers,any combination Min.0.25-inch DensDeck Prime plate or Drill-Tec 3"Recessed Steel Plate only) 2.13 ft2 FastLayn TPO Adhesive -45.0* structural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 57 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MOP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.1.5-inch EnergyGuard Polyiso Min.22 ga.,Type B,Grade Insulation,EnergyGuard RA,Min.0.25- 5-327. 33 steel ga min.2,500 psi ( Note 2 Optional)One or more inch DensDeck Prime or SECUROCK 1 per EverGuard TPO/ _q5.0* structural concrete layers,any combination Gypsum-Fiber Roof Board or Min.0.5- 2.0 ft2FastLayn TPO Adhesive inch EnergyGuard HD Polyiso Insulation Min.22ga.,Type B,Grade One or more layers,any Min.0.25-inch DensDeck Prime or 1 per EverGuard TPO/ 5-328. 33 steelel min.2,500 psi combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1.8 ft2 FastLayn TPO Adhesive -52.5 structural concrete Min.22 ga.,Type B,Grade Min.0.25-inch DensDeck Prime or One or more layers,any SECUROCK Gypsum-Fiber Roof Board 1 per EverGuard TPO/ 5-329. 33 steel min.2,500 psi combination or min.0.5-inch EnergyGuard HD 1.45 ft2 FastLayn TPO Adhesive structurall concrete Note 2 -60.0 Polyiso Insulation Min.22 ga.,Type B,Grade 5-330. 33 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso Note 2 1 pe EverGuard TPO/ -67.5 structural concrete layers,any combination Insulation 1.8 ft2FastLayn TPO Adhesive Min.22 ga.,Type B,Grade (Optional)One or more Min.2-inch EnergyGuard Polyiso 1 per EverGuard TPO/ 5-331. 33 steel or min.2,500 psi layers,any combination Insulation Note 2 1.45 ft2 FastLayn TPO Adhesive 82.5 structural concrete Min.22 ga.,Type B,Grade 5-332. 40 steel or min.2,500 psi (Optional)One or more Min.2-inch EnergyGuard Polyiso Note 2 1 per EverGuard TPO/ -90.0 structural concrete layers,any combination Insulation 1.45 ft2 FastLayn TPO Adhesive Triposite Roofing System: Min.22 ga.,Type B,Grade (Optional)One or more Min.1.5-inch EnergyGuard Polyiso 1 per Triposite System/ 5-333. 33 steel or min.2,500 psi layers,any combination Insulation,EnergyGuard Ultra, Note 2 2.0 ft2 Note 15C -45.0* structural concrete EnergyGuard RA or EnergyGuard RN Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 5-334. 33 steel or min.2,500 psi (Optional)One more Insulation,EnergyGuard Ultra, Note 2 .pe 2 ft z Note 15C Triposite System/ layers _45.0* structural concrete ,any combbination EnergyGuard RA or EnergyGuard RN 3 Min.22 ga.,Type B,Grade Min.2-inch EnergyGuard Polyiso 5-335. 33 steel or min.2,500 psi (Optional)One more Insulation,EnergyGuard Ultra or Note 2 .0 ft Note 15C per Triposite System/ layers -60.0 structural concrete ,any combbination EnergyGuard RA 2. Min.22 ga.,Type B, Min.2-inch EnergyGuard Polyiso 5-336. Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard Ultra or Note 2 1 per Triposite System/ -75.0 2,500 psi structural layers,any combination EnergyGuard RA 1.45 ft2 Note 15C concrete HYBRID ROOFING SYSTEM: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 58 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, Min.0.25-inch DensDeck,DensDeck 5-337. Grade 33 steel or min. (Optional)One or more prime or SECUROCK Gypsum-Fiber Note 2 1 per i Hybrid System/Note _qS.O* 2,500 psi structural layers,any combination Roof Board 4.0 ft 15D concrete EverGuard TPO Fleece-Back Membrane in Hot Asphalt: Min.22 ga.,Type B, EverGuard TPO Fleece- 5-338. Grade 33 steel or min. (Optional)One or more Min.0.25-inch DensDeck Prime Note 2 1 per Back Membrane/Hot -45.0* 2,500 psi structural layers,any combination 1.8 ft' asphalt concrete EverGuard TPO Fleece-Back Membrane in EverGuard WB181 Bonding Adhesive: Min.22 ga.,Type B, EverGuard TPO Fleece- 5-339. Grade 33 steel or min. (Optional)One or more Min.1.5-inch EnergyGuard RA, Note 2 1 per Back Membrane/ -30.0* 2,500 psi structural layers,any combination EnergyGuard RN,EnergyGuard RH 3.2 ft' WB181 concrete Min.22 ga.,Type B, Note 2 EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard Polyiso 6 parts per min.4 x 8 ft board with parts installed 36-inch o.c. 1 per 5-340. 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 5.3 ft2 Back Membrane/ -30.0* WB181 concrete board Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or EverGuard TPO Fleece- 5-341. Grade 33 steel or min. One or more layers,any Min.0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates orwith Drill-Tec ASAP 3S or Drill- 1 per Back Membrane/ -30.0* 2,500 psi structural combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft' WB181 concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard Ultra, 1 per 5-342. 2,500 psi structural layers,any combination EnergyGuard RA,EnergyGuard RN, Note 2 2.7 ft2 Back Membrane/ -37.5* concrete EnergyGuard RH WB181 Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- 5-343. Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 per Back Membrane/ -45.0* 2,500 psi structural layers,any combination EnergyGuard RA,EnergyGuard RN, 2.0 ft' WB181 concrete EnergyGuard RH Min.22 ga.,Type B, Note 2 EverGuard TPO Fleece- 5-344. Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard Polyiso 8 parts per min.4 x 8 ft board with parts installed 24-inch o.c. 1 per Back Membrane/ -45.0* 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges ofthe 4.0 ft2 WB181 concrete board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 59 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or EverGuard TPO Fleece- S-345. Grade 33 steel or min. One or more layers,any Min.0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per Back Membrane/ -45.0* 2,500 psi structural combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 3.2 ft2 WB181 concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or EverGuard TPO Fleece- Grade 33 steel or min. One or more layers,any Min.0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 5-346. 2,500 psi structural combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft2 Back Membrane/ -45.0* W 6181 concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B, EverGuard TPO Fleece- 5-347. Grade 33 steel or min. One or more layers,any Min.0.25-inch SECUROCK Gypsum- Note 2 1 per Back Membrane/ -52.5 2,500 psi structural combination,min.1-inch Fiber Roof Board 1.8 ft2 WB181 concrete Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. One or more layers,any Min.0.375-inch SECUROCK Gypsum- 1 per S-348. 2,500 psi structural combination,min.1-inch Fiber Roof Board Note 2 1.3 ft2 Back Membrane/ -67.5 concrete WB181 EverGuard TPO Fleece-Back Membrane in LRF Adhesive M or LRF Adhesive O: Min.22 ga.,Type B, EverGuard TPO Fleece- S-349. Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard Polyiso Note 2 1 per Back Membrane/LRF- _30.0* 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra 4.0 W M or LRF-O,12-inch concrete O.C. Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- S-350. Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 per Back Membrane/LRF- _37.5* 2,500 psi structural layers,any combination EnergyGuard RA,EnergyGuard RN, 2.7 ft2 M or LRF-O,12-inch concrete EnergyGuard RH O.C. Min.22 ga.,Type B, EverGuard TPO Fleece- S-351. Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard RA, Note 2 1 per Back Membrane/LRF- _37.5* 2,500 psi structural layers,any combination EnergyGuard RN,EnergyGuard RH 4.0 ft2 M or LRF-O,12-inch concrete O.C. Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more 1 per 5-352. 2,500 psi structural layers,any combination Min.1.75-inch ACFoam Composite/GB Note 2 5.3 ft2 Back Membrane/LRF- -37.5* concrete M,12-inch o.c. Min.22 ga.,Type B, EverGuard TPO Fleece- S-353. Grade 33 steel or min. One or more layers,any Min.0.25-inch Temple Green Glass Note 2(Drill-Tec 3"Standard Steel Plate or AccuTrac 1 per Back Membrane/LRF- _37.5* 2,500 psi structural combination Primed Roof Board Flat Plate only) 2.0 ft2 M or LRF-O,12-inch concrete O.C. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 60 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, EverGuard TPO Fleece- 5-354. Grade 33 steel or min. One or more layers,any Min.0.25-inch DensDeck Prime Note 2(Drill-Tec3"Standard Steel Plate,AccuTrac Flat 1 per Back Membrane/LRF- -37.5* 2,500 psi structural combination Plate or Drill-Tec3"Flat Steel Plate only) 2.0 ft2 M,12-inch o.c. concrete Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- S-355. Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard Ultra, Note 2 1 per Back Membrane/LRF- _45.0* 2,500 psi structural layers,any combination EnergyGuard RA,EnergyGuard RN, 2.0 ft2 M or LRF-O,12-inch concrete EnergyGuard RH O.C. Note 2 I per Min.22 ga.,Type B, �o 0 0 0 0 w 2.3 ft2 EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.2.5-inch EnergyGuard Polyiso - (14 Back Membrane/LRF- 5-356. 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra 0 0 0 o parts M or LRF-0,12-inch -45.0 concrete per4x8 O.L. 0 0 0 0 0 ftboard) x F Min.22 ga.,Type B, Min.2-inch EnergyGuard Polyiso EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard Ultra, 1 per Back Membrane/LRF- 5-357. 2,500 psi structural layers,any combination EnergyGuard RA,EnergyGuard RN, Note 2 2.9 ft2 M or LRF-0,12-inch -45.0* concrete EnergyGuard RH O.C. Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more 1 per 5-358. 2,500 psi structural layers,any combination Min.1.75-inch ACFoam Composite/GB Note 2 5.3 ft2 Back Membrane/LRF- -45.0* concrete 0,12-inch o.c. Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. One or more layers,any Note 2(Drill-Tec 3"Standard Steel Plate,AccuTrac Flat 1 per S-359. 2,500 psi structural combination Min.0.25-inch DensDeck Prime Plate or Drill-Tec3"Flat Steel Plate only) 2.0 ft2 Back Membrane/LRF- -45.0* concrete 0,12-inch o.c. Min.22 ga.,Type B, EverGuard TPO Fleece- S-360. Grade 33 steel or min. One or more layers,any Min.0.25-inch SECUROCK Gypsum- Note 2(Drill-Tec 3"Standard Steel Plate,AccuTrac Flat 1 per Back Membrane/LRF- _45.0* 2,500 psi structural combination Fiber Roof Board Plate or Drill-Tec 3"Flat Steel Plate only) 2.0 ft2 M or LRF-0,12-inch concrete O.C. Min.22 ga.,Type B, EverGuard TPO Fleece- S-361. Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard RH Note 2(Drill-Tec 3"Steel Plate only) 1 per Back Membrane/LRF- -52.5 2,500 psi structural layers,any combination 1.8 ft2 M or LRF-0,12-inch concrete o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 61 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, EverGuard TPO Fleece- S-362. Grade 33 steel or min. One or more layers,any Min.0.25-inch SECUROCK Gypsum- Note 2 1 per Back Membrane/LRF- -52.5 2,500 psi structural combination,min.1-inch Fiber Roof Board 1.8 ft2 M or LRF-O,12-inch concrete O.C. Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.1.5-inch EnergyGuard Polyiso 1 per Back Membrane/LRF- 5-363. 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra Note 2 1.3 ft2 M or LRF-O,12-inch -60.0 concrete O.C. Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.1.5-inch EnergyGuard Polyiso 1 per 5-364. 2,500 psi structural layers,any combination Insulation Note 2 1.3 ft2 Back Membrane/LRF- -67.5 M,12-inch o.c. concrete Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or EverGuard TPO Fleece- Grade 33 steel or min. One or more layers,any Min.0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 5-365. 2,500 psi structural combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft2 Back Membrane/LRF. -30.0* concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat M or LRF-O,4-inch o.c. Steel Plate Min.22 ga.,Type B, EverGuard TPO Fleece- S-366. Grade 33 steel or min. (Optional)One or more Min.1.5-inch EnergyGuard RH, Note 2 1 per Back Membrane/LRF- -45.0* 2,500 psi structural layers,any combination EnergyGuard RN 2.0 ft2 M or LRF-O,Membrane/ /LRF- Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard RH, 1 per 5-367. 2,500 psi structural layers,any combination EnergyGuard RN Note 2 2.9 ft2 Back Membrane/LRF -45.0* M or LRF-O,4-inch o.c.. concrete Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- 5-368. Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard RH, Note 2 1 pe 2 Back Membrane/LRF- -60.0 2,500 psi structural layers,any combination EnergyGuard RN,EnergyGuard RN I ft M or LRF-0,4-inch o.c. concrete Min.22 ga.,Type B, EverGuard TPO Fleece- S-369. Grade 33 steel or min. (Optional)One or more Min.0.25-inch DensDeck Prime Note 2 1 per Back Membrane/LRF- -45.0* 2,500 psi structural layers,any combination 2.0 ft2 M or LRF-O,4-inch o.c. concrete Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or EverGuard TPO Fleece- S-370. Grade 33 steel or min. One or more layers,any Min.0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 35 or Drill- 1 per Back Membrane/LRF- -45.0* 2,500 psi structural combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 3.2 ft2 concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat M or LRF-O,4-inch o.c. Steel Plate NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 62 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or EverGuard TPO Fleece- S-371. Grade 33 steel or min. One or more layers,any Min.0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates orwith Drill-Tec ASAP 3S or Drill- 1 per Back Membrane/LRF- -45.0* 2,500 psi structural combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or 4.0 ft2 M or LRF-0,4-inch o.c. concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate Min.22 ga.,Type B, EverGuard TPO Fleece- S-372. Grade 33 steel or min. One or more layers,any Min.0.375-inch SECUROCK Gypsum- Note 2 1 per Back Membrane/LRF- -67.5 2,500 psi structural combination Fiber Roof Board 1.3 ft2 M or LRF-0,Membrane/ RF- concrete EverGuard TPO Fleece-Back Membrane in Spatter Applications: Min.22 ga.,Type B, Note 2 EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard Polyiso 1 per Back MembraneL GAF 5-373. ( P ) Sy y 6 parts per min.4 x 8 ft board with parts installed 36-inch o.c. P 2-Part(spatter),LRF-XF -30.0* 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 5.3 ft2 (spatter)or OB500 concrete board (spatter) Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard EverGuard TPO Fleece- Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or Back Membrane GAF Grade 33 steel or min. One or more layers,any Min.0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 5-374. 2,500 psi structural combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft2 a (spatter),LRF-XF -30.0* (spatter)or 06500 concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat (sp Steel Plate (spatter) EverGuard TPO Fleece- Min.22 ga.,Type B, Grade 33 steel or min. (Optional)One or more Min.1.5-inch EnergyGuard Polyiso 1 per Back Membrane L GAF 5-375. 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra Note 2 2.7 ft2 (s Part(spatter), RF-XF -37.5* concrete (spatter)or OB500 (spatter) Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.1.5-inch EnergyGuard Polyiso 1 per Back Membrane/GAF S-376. Grad psi structural layers,any combination Insulation,EnergyGuard Ultra, Note 2 2 0 ft2 2-Part(spatter),LRF-XF -45.0* 2,500 EnergyGuard RH,EnergyGuard RN (spatter)or OB500 concrete (spatter) Note 2 1 per EverGuard TPO Fleece- Min.22 ga.,Type B, 0 0 0 0 0 2.3 ft2 Back Membrane/GAF Grade 33 steel or min. (Optional)One or more Min.2.5-inch EnergyGuard Polyiso - 14 5-377. 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra o 0 0 o parts pa (spatter LRF-XF -45.0 (spattter)or OB5s concrete per4x8 (s00 0 0 0 0 o ftboard) (spatter) a F NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 63 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, Note 2 EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard Polyiso 8 parts per min.4 x 8 ft board with parts installed 24-inch o.c. 1 per Back Membrane GAF 5-378. 2,500 psi structural layers,any combination Insulation,EnergyGuard Ultra in two parallel rows,12 inches from the 8 ft edges of the 4.0 ft' (spaattter)or OB500 (spatter),LRF-XF -45.0* concrete board (spatter) (spatter) Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Min.2-inch EnergyGuard Ultra, 1 per Back Membrane L GAF 5-379. 2,500 psi structural layers,any combination EnergyGuard RH,EnergyGuard RN Note 2 2.9 ft' (s Part(spatter), RF-XF -45.0* concrete (spatter)or OB500 (spatter) Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more Insulation,EnergyGuard Ultra, 1 per Back Membrane/GAF 5-380. 2,500 psi structural layers,any combination EnergyGuard RH,EnergyGuard RN, Note 2 1.3 ft2 2-Part(spatter),LRF-XF -60.0 concrete EnergyGuard RN (spatter)or OB500 (spatter) Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional)One or more 1 per Back Membrane/GAF 5-381. 2,500 psi structural layers,any combination Min.0.25-inch DensDeck Prime Note 2 2.0 ft' 2-Part(spatter),LRF-XF -45.0* concrete (spatter)or OB500 (spatter) Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard EverGuard TPO Fleece- Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or Back Membrane/GAF S-382. Grade 33 steel or min. One or more layers,any Min.0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 2-Part(spatter),LRF-XF -45.0* 2,500 psi structural combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 3.2 ft' concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat (spatter)or OB500 Steel Plate (spatter) Drill-Tec#12(steel only)or#14 with Drill-Tec 3"Standard EverGuard TPO Fleece- Min.22 ga.,Type B, Steel Plates,Drill-Tec 3 in.Ribbed Galvalume Plates(Flat)or Back Membrane/GAF S-383. Grade 33 steel or min. One or more layers,any Min.0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 2-Part(spatter),LRF-XF -45.0* 2,500 psi structural combination,min.1-inch Fiber Roof Board Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fasteneror 4.0 ft' concrete Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat (spatter)or OB500 Steel Plate (spatter) Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. One or more layers,any Min.0.25-inch DensDeck Prime or 1 per Back Membrane/GAF S-384. 2,500 psi structural combination,min.1-inch SECUROCK Gypsum-Fiber Roof Board Note 2 18 ft' 2-Part(spatter),LRF-XF -52.5 concrete (spatter)or OB500 (spatter) Min.22 ga.,Type B, EverGuard TPO Fleece- Grade 33 steel or min. One or more layers,any Min.0.375-inch SECUROCK Gypsum- 1 per Back Membrane/GAF 5-385. 2,500 psi structural combination Fiber Roof Board Note 2 1.3 ft' 2-Part(spatter),LRF-XF -67.5 concrete (spatter)or OB500 (spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMD ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 64 of 156 NNEMO I etc. TABLE 2E:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck(Note 1) (Note 13) Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, One or more layers,min. EverGuard TPO Fleece- 5-386. Grade 33 steel or min. 1.5-inch EnergyGuard Min.0.375-inch SECUROCK Gypsum- Note 2 1 pert Back Membrane/ -82.5 concrete psi structural Polyiso Insulation Fiber Roof Board 1.45 ft OB500(spatter) concrete TABLE 2F:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED B System Deck(Note 1) Base Insulation Top Insulation Layer Roof Cover(Note 15) MDP No. Layer(Note 13) Type Fasten(Note 11) Attach Base Ply Cap Ply (psf) Asphalt-Applied Base Ply: Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3 in.Ribbed Galvalume Plate(Flat)or Drill-Tec AccuTrac Flat (Optional)One or Min.0.25-inch Ruberoid 20 Membrane/hot asphalt,GAF Grade 33 steel or Plate,Drill-Tec#12 DP Fastener(steel only),Drill-Tec#14 HD 1 per 5-387. more layers,any SECUROCK Gypsum- Smooth/hot 2-Part(spatter),LRF-XF -30.0* min.2,500 psi Fastener or Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3" 4.0 fti structural concrete combination Fiber Roof Board Flat Steel Plate or Drill-Tec#12 DPH Fastener(steel only)with Drill- asphalt (spatter)or OB500(spatter) Tec 3"Recessed Steel Plate or LRF-O,12-inch o.c. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate (Optional)One or Min.0.375-inch Ruberoid 20 Membrane/hot asphalt,GAF Grade 33 steel or (Flat)or Drill-Tec AccuTrac Flat Plate,Drill-Tec#12 DP Fastener 1 per 5-388. more layers,any SECUROCK Gypsum- Smooth/hot 2-Part(spatter),LRF-XF -45.0* min.2,500 psi (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD 4.0 ft' structural concrete combination Fiber Roof Board Fastener(steel only)with Drill-Tec 3"Flat Steel Plate or Drill-Tec asphalt (spatter)or OB500(spatter) #12 DPH Fastener(steel only)with Drill-Tec 3"Recessed Steel Plate or LRF-O,12-inch o.c. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate Grade 33 steel or (Optional)One or Min.0.25-inch Ruberoid 20 Membrane/hot asphalt,GAF (Flat)or Drill-Tec AccuTrac Flat Plate,Drill-Tec#12 DP Fastener 1 per 5-389. more layers,any SECUROCK Gypsum- Smooth/hot 2-Part(spatter),LRF-XF -45.0* min.2,500 psi (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD 3.2 ft' structural concrete combination Fiber Roof Board Fastener(steel only)with Drill-Tec 3"Flat Steel Plate or Drill-Tec asphalt (spatter)or OB500(spatter) #12 DPH Fastener(steel only)with Drill-Tec 3"Recessed Steel Plate or LRF-O,12-inch o.c. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate or Drill-Tec AccuTrac Flat Plate,Drill- (Optional)One or Min.0.25-inch Ruberoid 20 Membrane/hot asphalt,GAF Grade 33 steel or Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or Drill- 1 per 5-390. more layers,any SECUROCK Gypsum- 2 Smooth/hot (s Part(spatters LRFspa-XF -52.5 min.2,500 psi Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Fla[Steel Plate 1.6 ft structural concrete combination Fiber Roof Board or Drill-Tec#12 DPH Fastener(steel only)with Drill-Tec 3" asphalt (spatter)or OB500(spatter) Recessed Steel Plate or LRF-0,12-inch o.c. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate (Optional)One or Min.0.375-inch Ruberoid 20 Membrane/hot asphalt,GAF Grade 33 steel or (Flat)or Drill-Tec AccuTrac Flat Plate,Drill-Tec#12 DP Fastener 1 per 5-391. more layers,any SECUROCK Gypsum- Smooth/hot 2-Part(spatter),LRF-XF -60.0 min.2,500 psi (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD 1.3 fti structural concrete combination Fiber Roof Board Fastener(steel only)with Drill-Tec 3"Flat Steel Plate or Drill-Tec asphalt (spatter)or OB500(spatter) #12 DPH Fastener(steel only)with Drill-Tec 3"Recessed Steel Plate or LRF-O,12-inch o.c. Torch-Applied Base Ply: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 65 of 156 NNEMO I etc. ATTACHEDOF:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY INSULATION,BONDED BASE System Base Insulation Top Insulation Layer Roof Cover(Note 15) MDP No. Deck(Note 1) Layer(Note 13) Type Fasten(Note 11) Attach Base Ply Cap Ply (psf) Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3 in.Ribbed Galvalume Plate(Flat)or Drill-Tec AccuTrac Flat (Optional)One or Min.0.25-inch Ruberoid HW Membrane/hot asphalt,GAF Grade 33 steel or Plate,Drill-Tec#12 DP Fastener(steel only),Drill-Tec#14 HD 1 per 5-392. more layers,any SECUROCK Gypsum- 25 Smooth/ 2-Part(spatter),LRF-XF -30.0* min.2,500 psi Fastener or Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3" 4.0 fti structural concrete combination Fiber Roof Board Flat Steel Plate or Drill-Tec#12 DPH Fastener(steel only)with Drill- torch-applied (spatter)or OB500(spatter) Tec 3"Recessed Steel Plate Or LRF-0,12-inch O.C. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate (Optional)One or Min.0.375-inch Ruberoid HW Membrane/hot asphalt,GAF Grade 33 steel or (Flat)or Drill-Tec AccuTrac Flat Plate,Drill-Tec#12 DP Fastener 1 per 5-393. more layers,any SECUROCK Gypsum- 25 Smooth/ 2-Part(spatter),LRF-XF -45.0* min.2,500 psi combination Fiber Roof Board (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD 4.0 fti torch-applied (spatter)or OB500(spatter) structural concrete Fastener(steel only)with Drill-Tec 3"Flat Steel Plate or Drill-Tec #12 DPH Fastener(steel only)with Drill-Tec 3"Recessed Steel Plate Or LRF-O,12-inch o.c. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener with Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate (Optional)One or Min.0.25-inch Ruberoid HW Membrane/hot asphalt,GAF Grade 33 Steel or (Flat)or Drill-Tec AccuTrac Flat Plate,Drill-Tec#12 DP Fastener 1 per 5-394. more layers,any SECUROCK Gypsum- 25 Smooth/ 2-Part(spatter),LRF-XF -45.0* min.2,500 psi (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#IS EHD 3.2 fti structural concrete combination Fiber Roof Board Fastener(steel only)with Drill-Tec 3"Flat Steel Plate or Drill-Tec torch_applied (spatter)Or OBS00(spatter) #12 DPH Fastener(steel only)with Drill-Tec 3"Recessed Steel Plate or LRF-O,12-inch o.c. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate or Drill-Tec AccuTrac Flat Plate,Dr - (Optional)One or Min.015-inch ill Ruberoid HW Membrane/hot asphalt,GAF Grade 33 steel or Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or Drill- 1 per 5-395. more layers,any SECUROCK Gypsum- 25 Smooth/ 2-Part(spatter),LRF-XF -52.5 min.2,500 psi Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Fla[Steel Plate 1.6 fti structural concrete combination Fiber Roof Board or Drill-Tec#12 DPH Fastener(steel only)with Drill-Tec 3" torch-applied (spatter)Or OB500(spatter) Recessed Steel Plate or LRF-O,12-inch o.c. One or more Min.0.25-inch Ruberoid HW EverGuard TPO Fleece-Back Min.22 ga.,type B, layers,any DensDeck Prime or 1 per 25 Smooth, Membrane/hot asphalt,GAF S-396. Grade 40 steel or combination, SECUROCK Gypsum- Note 2 1.45 ft2 Ruberoid HW 2-Part(spatter),LRF-XF -60.0 structural concrete loose laid Fiber Roof Board Smooth/torch- (spatter)or OB500(spatter) applied or LRF-O,12-inch o.c. Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalumeate Plate (Optional)One or Min.0.375-inch Ruberoid HW Membrane/hot asphalt,GAF Grade 33 Steel or (Flat)or Drill-Tec AccuTrac Flat Plate,Drill-Tec#12 DP Fastener 1 per 5-397. more layers,any SECUROCK Gypsum- 25 Smooth/ 2-Part(spatter),LRF-XF -60.0 min.2,500 psi (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#IS EHD 1.3 fti structural concrete combination Fiber Roof Board Fastener(steel only)with Drill-Tec 3"Flat Steel Plate or Drill-Tec torch-applied (spatter)or OB500(spatter) #12 DPH Fastener(steel only)with Drill-Tec 3"Recessed Steel Plate or LRF-O,12-inch o.c. Self-Adhering Base Ply: Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastenerwith Drill- EverGuard TPO Fleece-Back Min.22 ga.,Type B, Liberty g C Self- (Optional)One or Min.0.25-inch Tec 3 in.Ribbed Galvalume Plate(Flat)or Drill-Tec AccuTrac Flat Membrane/hot asphalt,GAF S-398. Grade 33 steel or more layers,an SECUROCK Gypsum- Plate or Drill-Tec#12 DP Fastener steel only),Drill-Tec#14 HD 1 per Adhering Cap 2-Part(spatter),LRF-XF -30.0* Y Y Yp ( v), min.structural psi 4.0 ft� Sheet/self- combination Fiber Roof Board Fastener or Drill-Tec#15 EHD Fastener(steel only)with Drill-Tec 3" (spatter)or OB500(spatter) structural concrete Flat Steel Plate adhered or LRF-0,12-inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 66 of 156 NNEMO I etc. ATTACHEDOF:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY INSULATION,BONDED BASE System Base Insulation Top Insulation Layer Roof Cover(Note 15) MDP No. Deck(Note 1) Layer(Note 13) Type Fasten(Note 11) Attach Base Ply Cap Ply (psf) Min.22 ga.,Type B, Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener with Drill- Liberty SBS Self- EverGuard TPO Fleece-Back (Optional)One or Min.0.375-inch Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalum 1 per A e Plate Membrane/hot asphalt,GAF 5-399. Grade 33 steel or more layers,any SECUROCK Gypsum- (Flat)or Drill-Tec AccuTrac Flat Plate or Drill-Tec#12 DP Fastener dhering Cap 2-Part(spatter),LRF-XF -45.0* .min.2,500 psi 40 ft2 Sheet/self- combination Fiber Roof Board (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#IS EHD (spatter)or OB500(spatter) structural concrete Fastener(steel only)with Drill-Tec 3"Flat Steel Plate adhered or LRF-O,12-inch o.c. Min.22 ga.,Type B, Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener with Drill- Liberty SBS Self- EverGuard TPO Fleece-Back (Optional)One or Min.0.25-inch Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate Membrane/hot asphalt,GAF 5-400. Grade 33 steel or more layers,any SECUROCK Gypsum- (Flat)or Drill-TecAccuTrac Flat Plate or Drill-Tec#12 DP Fastener .per Adhering Cap 2-Part(spatter),LRF-XF -45.0* min.2,500 psi steel only), 3.2 ft2 Sheet/self- structural concrete combination Fiber Roof Board ( (steel D l Drill-Tec with H r Fastener or Drill-Tec to EHD adhered (spatter) 1 -inch (spatter) Fastener(steel only)with Drill-Tec 3"Flat Steel Plate or LRF-O,12-inch o.c. Min.22 a.,Type B, Liberty SBS Self- EverGuard TPO Fleece-Back g YP Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener with Drill- Y (Optional)One or Min.0.25-inch Membrane/hot asphalt,GAF Grade 33 Steel or Tec 3"Standard Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill- 1 per Adhering Cap 5-401. more layers,any SECUROCK Gypsum- z 2-Part(spatter),LRF-XF -52.5 min.2,500 psi Tec#12 DP Fastener(steel only),Drill-Tec#14 HD Fastener or Drill- 1.6 ft Sheet/self- structural concrete combination Fiber Roof Board Tec#15 EHD Fastener(steel only)with Drill-Tec 3"Flat Steel Plate adhered (spatter)or OB500(spatter) or LRF-0,12-inch o.c. Min.22 ga.,Type B, Drill-Tec#12 Fastener(steel only),Drill-Tec#14 Fastener with Drill- Liberty SBS Self- EverGuard TPO Fleece-Back (Optional)One or Min.0.375-inch Tec 3"Standard Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate Membrane/hot asphalt,GAF min.2,500 psi 1.3 ft� Sheet/self- 5-402. Grade 33 steel or more layers,any SECUROCK Gypsum- (Flat)or Drill-TecAccuTrac Flat Plate or Drill-Tec#12 DP Fastener 1 per Adhering Cap 2-Part(spatter),LRF-XF -60.0 Combination Fiber Roof Board (steel only),Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD (spatter)or OB500(spatter) structural concrete Fastener(steel only)with Drill-Tec 3"Flat Steel Plate adhered or LRF-0,12-inch o.c. CONCRETETABLE 2G:STEEL OR STRUCTURAL .ECKS-NEW CONSTRUCTION,REROO • RECOVER VAPORSYSTEM TYPE C-1A:THERMAL BARRIER WITH .INSULATION,BONDED ROOCOVER System Top Insulation Layer Roof Cover MDP No. Deck(Note 1) Thermal Barrier/Vapor Barrier Type Fasten(Note 11) Attach (Note 15) (psf) EverGuard Freedom TPO: Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard Grade 33 steel or Min.1.5-inch EnergyGuard Polyiso Insulation, Note 2(no 1 per 5-403. min.2,500 psi SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN recessed plate) 2.0 ft2 Freedom TPO/ -45.0* structural concrete covered with GAF SA Vapor Retarder,self-adhered self adhered Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard Grade 33 steel or Note 2(no 1 per 5-404. min.2,500 psi SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.2-inch EnergyGuard RA,EnergyGuard RN recessed plate) 4.0 ft2 Freedom TPO/ -45.0* l covered with GAF SA Vapor Retarder,self-adhered self adhered structura concrete Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min 0.5-inch EverGuard Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2(no 1 per 5-405. min.2,500 psi SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard RH,loose laid,followed by min.0.25-inch recessed plate) 2.0 ft2 Freedom TPO/ -45.0* structural concrete covered with GAF SA Vapor Retarder,self-adhered SECUROCK Gypsum-Fiber Roof Board self adhered NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 67 of 156 NNEMOjetc. TABLE 2G:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-IA:THERMAL BARRIER WITH VAPOR BARRIER,MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover MDP No Deck(Note 1) Thermal Barrier/Vapor Barrier Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, Min.1.5-inch EnergyGuard RH,loose laid,followed by Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard Grade 33 steel or min.0.5-inch EnergyGuard RH HD Polyiso Insulation, Note 2(no 1 per 5-406. SECUROCK Gypsum-Fiber Roof Board,loose-laid, a Freedom TPO/ -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard HD Polyiso Insulation,EnergyGuard HD Plus recessed plate) 2.0 ft self adhered structural concrete Polyiso Insulation Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard Grade 33 steel or Note 2(#14)(no 1 per 5-407. min.2,500 psi SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.2-inch EnergyGuard RA,EnergyGuard RN recessed plate) 2.0 ft2 Freedom TPO/ -52.5 covered with GAF SA Vapor Retarder,self-adhered self adhered structural concrete EverGuard TPO/EverGuard TPO#1122.Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/ 5-408. Grade steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 .per 5 min. #1121,TPO 3- -45.0* structturalural concrete 2.psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH 0 ft2 Square Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ 5-409. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.2-inch EnergyGuard RA,EnergyGuard RN, Note 2 1 per #1121,TPO 3- -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH 4.0 ft' Square structural concrete Min.22 ga.,Type B, ,Min.1.5-inch EnergyGuard Polyiso Insulation Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-410. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 #1121,TPO 3- -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 2.0 ft2Square structural concrete DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B, .Min 1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ 5-411. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per #1121,TPO 3- -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.5-inch 3.2 ft2 Square structural concrete DensDeck Prime Min.22 ga.,Type B, .Min 1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-412. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 a #1121,TPO 3- -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.625-inch 4.0 ft Square structural concrete DensDeck Prime Min.22 ga.,Type B, Min.1.5-inch EnergyGuard RH,loose laid,followed by Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or min.0.5-inch EnergyGuard RH HD Polyiso Insulation, 1 per 5-413. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 #1121,TPO 3- -45.0* min.structural psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard HD Polyiso Insulation,EnergyGuard HD Plus 2.0 ft2 Square structural concrete Polyiso Insulation Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per F SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 #1121,TPO 3- -52.5 min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.45 ft2 Square structural concrete DensDeck Prime NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 68 of 156 NNEMOjetc. TABLE 2G:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-IA:THERMAL BARRIER WITH VAPOR BARRIER,MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover MDP No Deck(Note 1) Thermal Barrier/Vapor Barrier Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, .Min.15-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-415. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 a #1121,TPO 3- -52.5 min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.6 ft Square structural concrete SECUROCK Gypsum-Fiber Roof Board EverGuard TPO/EverGuard WB381 Bonding Adhesive: Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, 5-416. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per EverGuard TPO/ -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH 2.0 ft2 WB181 structural concrete Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch 5-417. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.2-inch EnergyGuard RA,EnergyGuard RN, Note 2 1 per EverGuard TPO/ -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH 4.0 ft2 WB181 structural concrete Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per EverGuard TPO/ 5-418. min.2,500 psi covered i Gypsum-Fiber Roof Board,loose-laid, EnergyGuard RH,loose laid,followed by min.0.25-inch Note 2 2.0 ft' WB181 -45.0* structural concrete Covered with GAF SA Vapor Retarder,self-adhered DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation, Grade 33 steel or Min.ROCK inch DensDeck Prime or min.se-finch EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per EverGuard TPO/ 5-419. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 : -45.0* min.structural psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.5-inch 3.2 ft2 W8181 structural concrete DensDeck Prime Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch 5-420. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per EverGuard TPO/ -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.625-inch 4.0 ft2 WB181 structural concrete DensDeck Prime Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard RH,loose laid,followed by Grade 33 steel or min.0.5-inch EnergyGuard RH HD Polyiso Insulation, 1 per EverGuard TPO/ 5-421. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard HD Polyiso Insulation,EnergyGuard HD Plus 2.0 ft2WB181 structural concrete Polyiso Insulation Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per EverGuard TPO/ 5-422. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 -52.5 min. psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.45 ft2 WB181 structturalural concrete DensDeck Prime Min.22 ga.,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per EverGuard TPO/ 5-423. min.2,500 psi covered i Gypsum-Fiber Roof Board,loose-laid, EnergyGuard RH,loose laid,followed by min.0.25-inch Note 2 1.6 ft2 WB181 -52.5 structural concrete covered with GAF SA Vapor Retarder,self-adhered SECUROCK Gypsum-Fiber Roof Board EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 69 of 156 NNEMOjetc. TABLE 213:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-IA:THERMAL BARRIER WITH VAPOR BARRIER,MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover MDP No Deck(Note 1) Thermal Barrier/Vapor Barrier Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/ S 424 Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per TPO 6-Square, -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH 2.0 ft' TPO 3-Square structural concrete Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ S-425. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.2-inch EnergyGuard RA,EnergyGuard RN, Note 2 1 per i TPO 6-Square, -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH 4.0 ft TPO 3-Square structural concrete Min.22 ga.,Type B, .Min 1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-426. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 TPO 6-Square, -45.0* min.structural psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed -min.Roof inch 2.0 ft� TPO 3-Square structural concrete DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B, ,Min.1.5-inch EnergyGuard Polyiso Insulation Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ S-427. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 pe ,self-adhered TPO 6-Square, -45.0* min.2,500 psi covered with GAF SA Vapor Retarder EnergyGuard RH,loose laid,followed by min.0.5-inch 3.2 ft2 TPO 3-Square structural concrete DensDeck Prime Min.22 ga.,Type B, .Min 1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-428. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 TPO 6-Square, -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.625-inch 4.0 ft2 TPO 3-Square structural concrete DensDeck Prime Min.22 ga.,Type B, Min.1.5-inch EnergyGuard RH,loose laid,followed by Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or min.0.5-inch EnergyGuard RH HD Polyiso Insulation, 1 per S 429. min.2,500 psi SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard HD Polyiso Insulation,EnergyGuard HD Plus Note 2 2 0 ft2 TPO 6-Square, -45.0* structural concrete covered with GAF SA Vapor Retarder,self-adhered Polyiso Insulation TPO 3-Square Min.22 ga.,Type B, ,Min.1.5-inch EnergyGuard Polyiso Insulation Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-430. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 TPO 6-Square, -52.5 min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.45 ft2 TPO 3-Square structural concrete DensDeck Prime Min.22 ga.,Type B, .Min 1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard re, / Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per S-431. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 TPO 6-Square, -52.5 min. psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.6 ft2 TPO 3-Square structturalural concrete SECUROCK Gypsum-Fiber Roof Board EverGuard TPO/FASTLAYN TPO ADHESIVE: Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ S-432. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.1.5-inch EnergyGuard Polyiso Insulation, Note 2 1 per FastLayn TPO -45.0* min. psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RA 2.0 ft' Adhesive structuraltural concrete NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 70 of 156 NNEMOjetc. TABLE 2G:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-IA:THERMAL BARRIER WITH VAPOR BARRIER,MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover MDP No Deck(Note 1) Thermal Barrier/Vapor Barrier Type Fasten(Note 11) Attach (Note 15) (psf) Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ 5-433. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.2-inch EnergyGuard RA Note 2 1 pea FastLayn TPO -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered 4.0 ft Adhesive structural concrete Min.22 ga.,Type B, ,Min.1.5-inch EnergyGuard Polyiso Insulation Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-434. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 FastLayn TPO -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 2.0 ft2 Adhesive structural concrete DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Min.22 ga.,Type B, .Min 1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-435. min.2,500 psi SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard RH,loose laid,followed by min.0.5-inch Note 2 3.2 ft� FastLayn TPO -45.0* structural concrete covered with GAF SA Vapor Retarder,self-adhered DensDeck Prime Adhesive Min.22 ga., ,Type B, Min.1.5-inch EnergyGuard Polyiso Insulation Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-436. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 FastLayn TPO -45.0* min. psi covered with GAF SA Vapor Retarder self-adhered EnergyGuard RH,loose laid,followed by min.0.625-inch 4.0 ft2 Adhesive structuraltural ,concrete DensDeck Prime Min.22 ga.,Type B, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ 5-437. Grade 33 steel or SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.1.5-inch EnergyGuard RH,loose laid,followed by Note 2 1 per FastLayn TPO -45.0* min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered min.0.5-inch EnergyGuard HD Polyiso Insulation 2.0 ft2 Adhesive structural concrete Min.22 ga.,Type B, .Min 1.5-inch EnergyGuard Polyiso Insulation, Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Adhesive 1 per 5-438. min.2,500 psi So Gypsum-Fiber Roof Board,loose-laid, EnergyGuard RH,loose laid,followed by min.0.25-inch Note 2 1.45 ft2 FastLayn TPO -52.5 structural concrete covered vered with GAF SA Vapor Retarder,self-adhered DensDeck Prime Min.22 ga.,Type B, ,Min.1.5-inch EnergyGuard Polyiso Insulation Min.0.625-inch DensDeck Prime or min.0.5-inch EverGuard TPO/ Grade 33 steel or EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per 5-439. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 FastLayn TPO -52.5 min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.6 ft2 Adhesive structural concrete SECUROCK Gypsum-Fiber Roof Board EverGuard TPO Fleece-Back Membrane in EverGuard WB381 Bonding Adhesive: Min.22 ga.,Type EverGuard TPO Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, 5-440. B,Grade, steel SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 .pe 0 ft2 Fleece-Back Membrane/r min.2,5 2. -45.0* s500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH structural concrete W B181 Min.22 ga.,Type EverGuard TPO B,Grade 33 steel Min.ROCK inch DensDeck Prime or min.se-finch Min.2-inch EnergyGuard RA,EnergyGuard RN, 1 per Fleece-Back 5-441. or min.2,500 psi SECUROCK i Gypsum-Fiber Roof Board,loose-laid, EnergyGuard RH Note 2 4.0 W Membrane/ -45.0* structural concrete covered with GAF SA Vapor Retarder,self-adhered WB181 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 71 of 156 NNEMOjetc. VAPORTABLE 2G:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-IA:THERMAL BARRIER WITH BARRIER,MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover MDP No Deck(Note 1) Thermal Barrier/Vapor Barrier Type Fasten(Note 11) Attach (Note 15) IPAMin.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-442. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 2 B,Grade 33 steel EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 2.0 ft 1 per Fleece-Back -45.0* or min.2,500 psi EnergyGuard RH,loose laid,followed by min.0.25-inch covered with GAF SA Vapor Retarder,self-adhered Membrane/ structural concrete DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board WB181 Min.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO B,Grade 33 steel EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per Fleece-Back 5-443. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 -45.0* or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.5-inch 3.2 ft2 Membrane/ structural concrete DensDeck Prime WB181 Min.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO S 444 B,Grade 33 steel SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per Fleece-Back -45.0* or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.625-inch 4.0 ft2 Membrane/ structural concrete DensDeck Prime WB181 Min.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-445. B,Grade 33 steel SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per Fleece-Back -52.5 or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.45 ft2 Membrane/ structural concrete DensDeck Prime WB181 Min.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-446. B,Grade 33 steel SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per Fleece-Back -52.5 or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 1.6 ft2 Membrane/ structural concrete SECUROCK Gypsum-Fiber Roof Board WB181 EverGuard TPO Fleece-Back Membrane in LRF Adhesive M or LRF Adhesive O: Min.22 ga.,Type EverGuard TPO Min.0.625-inch DensDeck Prime or min.0.5-inch Fleece-Back B,Grade 33 steel Min.1.5-inch EnergyGuard RA,EnergyGuard RN, 1 per 5-447. SECUROCK Gypsum-Fiber Roof Board,loose-laid, Note 2 Membrane/URF- -45.0* or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH 2.9 ft' M or LRF-O,12- structural concrete inch o.c. Min.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO B,Grade 33 steel EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, 1 per Fleece-Back 5-448. SECUROCK i Gypsum-Fiber Roof Board,loose-laid, Note 2 -45.0* or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 2.0 ft2Membrane/LRF- structural concrete DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board 0,12-inch o.c. Min.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO S 449 B,Grade 33 steel SECUROCK Gypsum-Fiber Roof Board,loose-laid, EnergyGuard Ultra,EnergyGuard RA,EnergyGuard RN, Note 2 1 per Fleece-Back -45.0* or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard RH,loose laid,followed by min.0.25-inch 2.0 ft2 Membrane/LRF- structural concrete SECUROCK Gypsum-Fiber Roof Board M,12-inch o.c. EverGuard TPO Min.22 ga.,Type Min.0.625-inch DensDeck Prime or min.0.5-inch Fleece-Back 5-450. B,Grade 33 steel SECUROCK Gypsum-Fiber Roof Board,loose-laid, Min.1.5-inch EnergyGuard Polyiso Insulation, Note 2 1 per Membrane/LRF- -60.0 or min.2,500 psi covered with GAF SA Vapor Retarder,self-adhered EnergyGuard Ultra 1.3 ft2 M or LRF-0,12- structural concrete inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 72 of 156 NNEMO I etc. TABLE 2H:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-2:MECHANICALLY ATTACHED INSULATION,PLATE-BONDED ROOF COVER System Deck Insulation(Note 13) Attachment Roof Cover(Note 1513) MDP No. (Note 1) Fasteners(Note 11) Density (psf) One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min.22 ga., combination,preliminarily RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-451. type B,Grade attached(Tread Safe=min. or Drill-Tec RhinoBond TPO Max.18-inch o.c.in rows spaced max.60-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool, -30.0 33 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturer's published instructions. One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min.22 ga., 5-452. type B,Grade combination,preliminarily RhinoBond TPO XHD Plates Max.12-inch o.c.in rows spaced max.60-inch o.c. XHD Plates orDrill-Tec RhinoBond TPO XHD Tread -37.5 33 steel attached(Tread Safe=min. or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. Min.22 ga., One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-453. type B,Grade combination,preliminarily RhinoBond TPO XHD Plates Max.18-inch o.c.in rows spaced max.60-inch o.c. XHD Plates or Drill-Tec RhinoBond TPO XHD Tread -37.5 80 steel attached(Tread Safe=min. or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. One or more layers,any Drill-Tec XHD and Drill-Tec 1 per 5.3 ftz(6 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min.22 ga., Fasteners located in each of the four corners of the 5-454. type B,Grade combination,4 x 8 ft board; RhinoBond TPO XHD Plates board and at mid-span of the 96-inch length. XHD Plates or DrRhin c RhinoBond le B XHD Tread _37.5 33 steel (Tread Safe=min.2-inch or Drill-Tec RhinoBond TPO Fasteners are 12-inches from the board's long edges Safe Plates with RhinoBond Portable Bonding Tool, thick insulation) XHD Tread Safe Plates and 12-and 48-inches from the board's short edges. per manufacturers published instructions. Min.22 ga., One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-455. type B,Grade combination,preliminarily RhinoBond TPO XHD Plates Max.12-inch o.c.in rows spaced max.60-inch o.c. XHD Plates or Drill-Tec RhinoBond TPO XHD Tread _45.0 80 steel attached(Tread Safe=min. or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. 1 per 5.3 ftz(6 parts per 4 x 8 ft board) One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min.22 ga., Fasteners located in each of the four corners of the 5-456. type B,Grade combination,4 x 8 ft board; RhinoBond TPO XHD Plates board and at mid-span of the 96-inch length. XHD Plates or DrRhin c RhinoBond le B XHD Tread -45.0* (Tread Safe=min.2-inch or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, 33 steel thick insulation) XHD Tread Safe Plates Fasteners are 6-inches from the board's long edges per manufacturers published instructions. and 12-and 48-inches from the board's short edges. 1 per 5.3 ftz(6 parts per 4 x 8 ft board) Min.2,500 psi One or more layers any Drill-Tec ri14 and Drill-Tec Fasteners located in each of the four corners of the EverGuard TPO bonded to Drill-Tec RhinoBond TPO , 5-457. structural board and at mid-span of the 96-inch length. XHD Plates with RhinoBond Portable Bonding Tool, -45.0 concrete combination,4 x 8 ft board RhinoBond TPO XHD Plates Fasteners are 6-inches from the board's long edges per manufacturers published instructions. and 12-and 48-inches from the board's short edges. Min.22 ga., One or more layers,any Drill-Tec XHD and Drill-Tec 1 per 4.0 ft2(4 parts per 4 x 4 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-458. type B,Grade combination,4 x 4 ft board; RhinoBond TPO XHD Plates Fasteners located in each of the four corners of the XHD Plates or DrRhin c RhinoBond le B XHD Tread _q5.0* 33 steel (Tread Safe=min.2-inch or Dri readSafe RhinoBond TPO board. Fasteners are 12-inch from the board edges. Safe Plates with is published Portable Bonding Tool, thick insulation) XHD Tread Safe Plates per manufacturers published instructions. Min.2,500 psi One or more layers,any Drill-Tec ri14 and Drill-Tec 1 per 4.0 ft'(4 parts per 4 x 4 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-459. structural Fasteners located in each of the four corners of the XHD Plates with RhinoBond Portable Bonding Tool, -45.0* concrete combination,4 x 4 ft board RhinoBond TPO XHD Plates board. Fasteners are 12-inch from the board edges. per manufacturers published instructions. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 73 of 156 NNEMO I etc. TABLE 2H:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-2:MECHANICALLY ATTACHED INSULATION,PLATE-BONDED ROOF COVER System Deck Insulation(Note 13) Attachment Roof Cover(Note 1513) MDP No. (Note 1) Fasteners(Note 11) Density (psf) Min.22 ga., One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-460. type B,Grade combination(Tread Safe= RhinoBond TPO XHD Plates Max.24-inch o.c.in rows spaced max.30-inch o.c. XHD Plates or Drill-Tec RhinoBond TPO XHD Tread -52.5 33 steel min.2-inch thick insulation) or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, XHD Tread Safe Plates per manufacturer's published instructions. 1 per 4.0 ftz(8 parts per 4 x 8 ft board) One or more layers,any Drill-Tec XHD and Drill-Tec 9�"— EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min.22 ga., o bination,4 x 8 ft board; RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-461. type B,Grade com 5 -60.0 33 steel (Tread Safe=min.2-inch or Drill-Tec RhinoBond TPO x ® ♦:, Safe Plates with RhinoBond Portable Bonding Tool, thick insulation) XHD Tread Safe Plates per manufacturer's published instructions. ® 1 I i i Min.22 ga., One or more layers,any Drill-Tec SXHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-462. type B,Grade combination RhinoBond TPO SXHD Plates 24 x 24 inch grid SXHD Plates with RhinoBond Portable Bonding Tool, -60.0 33 steel per manufacturers published instructions. Min.2,500 psi One or more layers,any Drill-Tec#14 and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-463. structural combination RhinoBond TPO XHD Plates 24 x 24 inch grid XHD Plates with RhinoBond Portable Bonding Tool, -60.0 concrete per manufacturers published instructions. One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min.22 ga., combination,preliminarily RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-464. type B,Grade attached(Tread Safe=min. or Drill-Tec RhinoBond TPO Max.6-inch o.c.in rows spaced max.72-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool, -67.5 33 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. Min.22 ga., One or more layers,any Drill-Tec XHD and Drill-Tec 1 per 2.7 ft'(12 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond TPO RhinoBond TPO XHD Plates Fasteners are 6-,24-and 42-inches from the board's XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-465. type B,Grade combination(Tread Safe= -67.5 33 steel min.2-inch thick insulation) or Drill-Tec RhinoBond TPO long edge and 12-,36-,60-and 84-inches from the Safe Plates with RhinoBond Portable Bonding Tool, XHD Tread Safe Plates board's short edge. per manufacturers published instructions. 18 x 24 inch staggered grid Min.22 ga., One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-466. type B,Grade combination,(Tread Safe= RhinoBond TPO XHD Plates ® XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 82 5 40 steel min.2-inch) or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, XHD Tread Safe Plates ® ® per manufacturers published instructions. I0 m NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 74 of 156 NNEMO I etc. TABLE 2H:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-2:MECHANICALLY ATTACHED INSULATION,PLATE-BONDED ROOF COVER System Deck Insulation(Note 13) Attachment Roof Cover(Note 1513) MDP No. (Note 1) Fasteners(Note 11) Density (psf) 1 per 2.7 ft'(12 parts per 4 x 8 ft board) o Drill-Tec XHD and Drill-Tec -f EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min.22 ga., One or more layers,any RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-467. type B,Grade combination,(Tread Safe= o ® a i -82.5 or Drill-Tec RhinoBond TPO r�''. Safe Plates with RhinoBond Portable Bonding Tool, 40 steel min.2-inch) XHD Tread Safe Plates per manufacturer's published instructions. 0 0 0 0 Q Min.22 ga., One or more layers,any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO combination,preliminarily RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-468. type B,Grade attached(Tread Safe=min. or Drill-Tec RhinoBond TPO Max.6-inch o.c.in rows spaced max.72-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool, 97.5 80 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturer's published instructions. Min.22 ga., Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-469. type B,Grade One or more layers,any RhinoBond TPO XHD Plates 18 x 16 inch grid,staggered 6-inch XHD Plates or Drill-Tec RhinoBond TPO XHD Tread -105.0 60 steel combination,min.2-inch or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, XHD Tread Safe Plates I per manufacturer's published instructions. TABLE 21:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE• •ROOF COVER Insulation(Note 13) Roof Cover(Note 15A) System Deck MOP Attach Separator Sheet(Optional) No. (Note 1) Type (Note 5) Membrane Fasteners(Note 21) Attachment (psf) EverGuard TPO: IL EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed XHD One or more layers, i 18-inch o.c.within 6-inch wide Min.22 ga.,type B, Prelim. Separation Layer(3 oz/yd)or EverGuard Plates or Drill-Tec#15 EHD Fastener with Drill- 5-470. any combination, laps spaced 54-inch o.c.and -30.0 Grade 80 steel min.1-inch attach EverGuard Polymat TPO Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/ydt) Scoop Seam Plate EverGuard Polymat Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed XHD One or more layers, a)or Ever Plates or Drill-Tec Eyehook AccuSeam Plates or 12-inch o.c.within 6-inch wide Grade 33 steel 5-471. Min.22 ga.,type B, any combination, Prelim. Separation Layer at oz/yd TPO Guard Drill-Tec#15 EHD Fastener with Drill-Tec 2.4" laps spaced 114-inch o.c.and -30.0 min.1.5-inch attach EverGuard Polymat Barbed Seam Plate or Drill-Tec 2.4"Scoop Seam sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd�) Plate EverGuard Polymat Min.22 ga.,type B, One o more layers, Prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch spaced within h o.c.wide 5-472. any combination, laps spaced 115-inch o.c.and -30.0 Grade 80 steel min.1.5-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/ydt) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 75 of 156 NNEMO etc. ATTACHEDEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-1:MECHANICALLY ROOF Insulation(Note 13) Roof Cover(Note 15A) System Deck MDP No. (Note 1) Type Attach Separator Sheet(Optional)(Note 5) Membrane Fasteners(Note 11) Attachment (psf) EverGuard Polymat Drill-Tec XHD and Drill-Tec 2 in.Double Barbed 12-inch o.c.in rows spaced max. one or more layers, XHD Plates, , Min.22 ga.,type B, Prelim. Separation Layer at oz/ydz Drill-Tec 2-3/8 in.Barbed XHD Plates )or EverGuard 114-inch o.c.An 8-inch wide -30.0 Grade 33 steel 5-473. any combination, Drill-Tec Eyehook AccuSeam Plates or Drill-Tec attach EverGuard Polymat TPO cover strip is heat welded over min.1.5-inch #15 EHD Fastener with Drill-Tec 2.4"Barbed Cushioning Layer(6 oz/yd') Seam Plate or Drill-Tec 2.4"Scoop Seam Plate the stress plates. One or more layers, EverGuard Polymat i 12-inch o.c.within 6-inch wide S 474 Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/yd)or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed laps spaced 138-inch o.c.and -30.0 Grade 33 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd') EverGuard Polymat Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed XHD One or more layers, a 12-inch o.c.within 6-inch wide Min.22 ga.,type B, Prelim. Separation Layer(3 oz/yd)or EverGuard Plates or Drill-Tec#15 EHD Fastener with Drill- 5-475. any combination, laps spaced 138-inch o.c.and -30.0 Grade 60 steel min.1-inch attach EverGuard Polymat TPO Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/ydz) Scoop Seam Plate EverGuard Polymat One or more layers, 12-inch o.c.within 6-inch wide 5-476. Min.22 ga.,type B, any combination, Prelim. Separation Layer oz/ydi)or EverGuard Drill-Tec XHD or Drill-Tec SXHD with Drill-Tec 2 laps spaced 138-inch o.c.and -30.0 Grade 80 steel min.1-inch attach EverGuard Polymatat TPO 3/4 in.Barbed SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Drill-Tec XHD and Drill-Tec 2 in.Double Barbed One or more layers, a)or EverGuardXHD Plates,Drill-Tec 2-3/8 in.Barbed XHD Plates, 6-inch o.c.within 6-inch wide S 477 Grade 33 steel Min.22 ga.,type B, any combination, Prelim. Separation Layer attach EverGuard Polymat at oz/yd TPO Drill-Tec Eyehook AccuSeam Plates or Drill-Tec laps spaced 138-inch o.c.and -30.0 min.1-inch #15 EHD Fastener with Drill-Tec 2.4"Barbed sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd�) Seam Plate or Drill-Tec 2.4"Scoop Seam Plate One or more layers, EverGuard Polymat 12-inch o.c.within 6-inch wide S 478 Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/ydi)or EverGuard Drill-Tec XHD with Drill-Tec 2 in.Double Barbed laps spaced 90-inch o.c.and -37.5 Grade 33 steel min.1-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Min.22 ga.,type B, One or more layers, prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide 5-479. any combination, laps spaced 114-inch o.c.and -37.5 Grade 40 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) One or more layers, EverGuard Polymat i 12-inch spaced within h o.c.wide 5-480. Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/yd)or EverGuard Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. laps spaced 114-inch o.c.and -37.5 Grade 80 steel min.1.5-inch attach EverGuard Polymat TPO Barbed SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed XHD One or more layers, 12-inch o.c.within 5-inch wide Min.22 ga.,type B, Prelim. Separation Layer(3 oz/ydi)or EverGuard Plates or Drill-Tec#15 EHD Fastener with Drill- 5-481. any combination, laps spaced 115-inch o.c.and -37.5 Grade 80 steel min.1.5-inch attach EverGuard Polymat TPO Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd') Scoop Seam Plate NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 76 of 156 NNEMO I etc. ATTACHEDEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-1:MECHANICALLY ROOF Insulation(Note 13) Roof Cover(Note 15A) System Deck MOP No. (Note 1) Type Attach Separator Sheet(Optional)(Note 5) Membrane Fasteners(Note 11) Attachment (psf) One or more layers, EverGuard Polymat i 12-inch o.c.within 6-inch wide S 482 Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/yd)or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed laps spaced 138-inch o.c.and -37.5 Grade 80 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat One or more layers, prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec#14 Fasteners with Drill-Tec 2 3/4 in. 12-inch o.c.within 6-inch wide 5-483. Structural concrete any combination, laps spaced 138-inch o.c.and -37.5 min.1-inch attach EverGuard Polymat TPO Barbed SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Drill-Tec XHD and Drill-Tec 2 in.Double Barbed One or more layers, XHD Plates,Drill-Tec 2-3/8 in.Barbed XHD Plates, 6-inch o.c.within 6-inch wide S 484 Min.20 ga.,type B, any combination, Prelim. Separation Layer(3 oz/ydi)or EverGuard Drill-Tec Eyehook AccuSeam Plates or Drill-Tec laps spaced 138-inch o.c.and -37.5 Grade 33 steel attach EverGuard Polymat TPO min.1-inch #15 EHD Fastener with Drill-Tec 2.4"Barbed sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) Seam Plate or Drill-Tec 2.4"Scoop Seam Plate Drill-Tec XHD with Drill-Tec 2 in.Double Barbed EverGuard Polymat XHD Plates or Drill-Tec 2 3/8 in.Barbed XHD One or more layers, 12-inch o.c.within 6-inch wide Min.22 ga.,type B, Prelim. Separation Layer(3 oz/yd')or EverGuard Plates;or Drill-Tec SXHD with Drill-Tec 2 3/4 in. 5-485. any combination, laps spaced 54-inch o.c.and -45.0 Grade 33 steel attach EverGuard Polymat TPO Barbed SXHD Plates,or Drill-Tec#15 EHD min.1-inch Cushioning Layer(6 oz/yd2) Fastener with Drill-Tec 2.4"Barbed Seam Plate sealed with a 1.5-inch heat weld. or Drill-Tec 2.4"Scoop Seam Plate EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 in.Double Barbed Min.200 psi,min.2- a)or EverGuard XHD Plates,Drill-Tec Eyehook AccuSeam Plates 12-inch o.c.within 6-inch wide Grade 33 steel attach EverGuard Polymat 5-486. Min.22 ga.,type B, inch thick cellular Prelim. Separation Layer at oz/yd TPO or Drill-Tec 2-3/8 in.Barbed XHD Plates or Drill- laps spaced 54-inch o.c.and -45.0 lightweight concrete Tec#15 EHD Fastener with Drill-Tec 2.4"Barbed sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/ydi) Seam Plate or Drill-Tec 2.4"Scoop Seam Plate One or more layers, EverGuard Polymat 12-inch o.c.within 6-inch wide S 487 Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/ydi)or EverGuard Drill-Tec XHD with Drill-Tec 2 in.Double Barbed laps spaced 66-inch o.c.and -45.0 Grade 40 steel min.1-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Min.22 ga.,type B, One more layers, prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch within 6-inch wide 5-488. any combination, laps spacceded 90-inch o.c.and -45.0 Grade 33 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Min.20 ga.,type B, One o more layers, Prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch within 6-inch wide 5-489. any combination, laps spacceded 90-inch o.c.and -45.0 Grade 33 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd') NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 77 of 156 NNEMO etc. ATTACHEDEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-1:MECHANICALLY ROOF Insulation(Note 13) Roof Cover(Note 15A) System Deck MOP No. (Note 1) Type Attach Separator Sheet(Optional)(Note 5) Membrane Fasteners(Note 11) Attachment (psf) One or more layers, EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed XHD 6-inch o.c.within 5-inch wide Min.22 ga.,type B, Prelim. Separation Layer(3 oz/yfl or EverGuard Plates or Drill-Tec#15 EHD Fastener with Drill- laps spaced 114.5-inch o.c.and 5-490. Grade 80 steel any combination,min.1.5-inch attach EverGuard Polymat TPO Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.75-inch heat -45.0 Cushioning Layer(6 oz/yfl Scoop Seam Plate weld. EverGuard Polymat Min.22 ga.,type B, One or more layers, prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide 5-491. any combination, laps spaced 114-inch o.c.and -45.0 Grade 80 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed XHD Plates,Drill-Tec Eyehook AccuSeam Plates or EverGuard Polymat Min.22 ga.,type B, One or more layers, prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec 2 in.Double Barbed XHD Plates or Drill- 6-inch o.c.within 6-inch wide 5-492. any combination, Tec XHD or SXHD with Drill-Tec 2 3/4 in.Barbed laps spaced 138-inch o.c.and -45.0 Grade 60 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates or Drill-Tec#15 EHD Fastener with sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) Drill-Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed XHD EverGuard Polymat Plates,Drill-Tec Eyehook AccuSeam Plates or Min.18 ga.,type B, One or more layers, prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec 2 in.Double Barbed XHD Plates or Drill- 6-inch o.c.within 6-inch wide 5-493. any combination, Tec XHD or SXHD with Drill-Tec 2 3/4 in.Barbed laps spaced 138-inch o.c.and -45.0 Grade 33 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates or Drill-Tec#15 EHD Fastener with sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd�) Drill-Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec#14 Fasteners with Drill-Tec 2-3/8 in. EverGuard Polymat Barbed XHD Plates,Drill-Tec Eyehook AccuSeam One or more layers, 6-inch o.c.within 6-inch wide Prelim. Separation Layer(3 oz/yd:)or EverGuard Plates,Drill-Tec 2 in.Double Barbed XHD Plates 5-494. Structural concrete any combination, laps spaced 138-inch o.c.and -45.0 min.1-inch attach EverGuard Polymat TPO or Drill-Tec 2 3/4 in.Barbed SXHD Plates or Drill- sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) Tec#14 HD Fastener with Drill-Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4"Scoop Seam Plate One or more layers, EverGuard Polymat 12-inch o.c.within 6-inch wide 5-495. Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/yda)or EverGuard Drill-Tec XHD with Drill-Tec 2 in.Double Barbed laps spaced 54-inch o.c.and -52.5 Grade 40 steel min.1-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Min.22 ga.,type B, One more layers, prelim. Separation Layer(3 oz/yfl or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch within 6-inch wide 5-496. any combination, laps spaced 66-inch o.c.and -52.5 Grade 40 steel in.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 78 of 156 NNEMO I etc. ATTACHEDEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-1:MECHANICALLY ROOF Insulation(Note 13) Roof Cover(Note 15A) System Deck MOP No. (Note 1) Type Attach Separator Sheet(Optional)(Note 5) Membrane Fasteners(Note 11) Attachment (psf) EverGuard Polymat Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed XHD One or more layers, z Plates,Drill-Tec Eyehook AccuSeam Plates or 6-inch o.c.within 6-inch wide S 497 Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/yd)or EverGuard Drill-Tec 2 in.Double Barbed XHD Plates or Drill- laps spaced 114-inch o.c.and -52.5 Grade 33 steel attach EverGuard Polymat TPO min.1-inch Tec#15 EHD Fastener with Drill-Tec 2.4"Barbed sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd') Seam Plate or Drill-Tec 2.4"Scoop Seam Plate Drill-Tec#14 or Drill-Tec CD-10 fasteners with EverGuard Polymat Drill-Tec 2 in.Double Barbed XHD Plates,Drill- One or more layers, Prelim. 6-inch o.c.within 6-inch wide Separation Layer(3 oz/yd:)or EverGuard Tec 2-3/8 in.Barbed XHD Plates or Drill-Tec 5-498. Structural concrete any combination, attach or laps spaced 114-inch o.c.and -52.5 min.1.5-inch OB500 EverGuard Polymat TPO Eyehook AccuSeam Plates or Drill-Tec#14 HD sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) Fastener with Drill-Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4"Scoop Seam Plate Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed XHD EverGuard Polymat One or more layers, Plates or Drill-Tec 2 in.Double Barbed XHD 6-inch o.c.within 5-inch wide S 499 Min.22 ga.,type B, any combination, Prelim. Separation Layer oz/ydi)or EverGuard Plates or Drill-Tec#15 EHD Fastener with Drill- laps spaced 115-inch o.c.and -52.5 Grade 80 steel min.1.5-inch attach EverGuard Polymatat TPO Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd') Scoop Seam Plate One or more layers, EverGuard Polymat 6-inch o.c.within 6-inch wide 5-500. Min.22 ga.,type B, any combination, Prelim. Separation Layer(3 oz/ydz)or EverGuard Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. laps spaced 138-inch o.c.and -52.5 Grade 80 steel min.1-inch attach EverGuard Polymat TPO Barbed SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) One or more layers, EverGuard Polymat 6-inch o.c.within 6-inch wide 5-501. Structural concrete any combination, Prelim. Separation Layer(3 oz/yda)or EverGuard Drill-Tec#14 Fasteners with Drill-Tec 2 3/4 in. laps spaced 138-inch o.c.and -52.5 min.1-inch attach EverGuard Polymat TPO Barbed SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed XHD One or more layers, 6-inch o.c.within 6-inch wide Min.22 ga.,type B, Prelim. Separation Layer(3 oz/ydi)or EverGuard Plates or Drill-Tec#15 EHD Fastener with Drill- 5-502. any combination, laps spaced 54-inch o.c.and -60.0 Grade 33 steel min.1.5-inch attach EverGuard Polymat TPO Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) Scoop Seam Plate EverGuard Polymat Min.22 ga.,type B, One or more layers, Prelim. Separation Layer(3 oz/yd2)or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide 5-503. any combination, laps spaced 54-inch o.c.and -60.0 Grade 40 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed XHD One or more layers, 6-inch o.c.within 6-inch wide Min.22 ga.,type B, Prelim. Separation Layer(3 oz/ydi)or EverGuard Plates or Drill-Tec#15 EHD Fastener with Drill- 5-504. any combination, laps spaced 90-inch o.c.and -60.0 Grade 33 steel min.1-inch attach EverGuard Polymat TPO Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd') Scoop Seam Plate NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 79 of 156 NNEMO I etc. ATTACHEDEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-1:MECHANICALLY ROOF Insulation(Note 13) Roof Cover(Note 1SA) System Deck MDP No. (Note 1) Type Attach Separator Sheet(Optional)(Note 5) Membrane Fasteners(Note 11) Attachment (psf) EverGuard Polymat One or more layers, i 6-inch o.c.within 6-inch wide Prelim. Separation Layer at oz/yd)or EverGuard Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 5-505. Min.22 ga.,type B, any combination, laps spaced 114-inch o.c.and -60.0 Grade 33 steel min.1-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) EverGuard Polymat Min.22 ga.,type B, Min. psi,min.2- prelim. Separation Layer(3 oz/yd2)or EverGuard 12-inch within 6-inch wide 5-506. inch thichic k cellular Drill-Tec XHD with Drill-Tec 2-3/4 in.SXHD Plates laps spacedced 54-inch o.c.and -67.5 Grade 33 steel lightweight concrete attach EverGuard Polymat Cushioning Layer(6 oz/ydz TPO sealed with a 1.5-inch heat weld. ) EverGuard Polymat Fastened through to engage Min.22 ga.,type Min.330 psi,min.2- steel deck,6-inch o.c.within 6- 5-507. BV(0.5%),Grade inch thick Celcore N/A Separation Layer(3 oz/ydi)or EverGuard Drill-Tec XHD with Drill-Tec 2 in.Double Barbed inch wide laps spaced 114-inch -67.5 33 steel Cellular Concrete EverGuard Polymat TPO XHD Plates(to engage steel deck) o.c.and sealed with a 1.5-inch Cushioning Layer(6 oz/yd2) heat weld. One or more layers, i 6-inch o.c.within 6-inch wide 5-508. Min.22 ga.,type B, EverGuard Polymat any combination, Prelim. Separation Layer(3 oz/yd)or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed laps spaced 114-inch o.c.and -67.5 Grade 33 steel min.1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer(6 oz/yd2) 6-inch o.c.atop 6-inch wide EverGuard Polymat overlaps in rows spaced max. One or more layers, a EverGuard 5-509. Min.22 ga.,Type B, any combination, Prelim. Separation Layer(3 oz/yd)or TPO,min. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed XHD 138-inch o.c.An 8-inch wide -67.5 Grade 80 steel min.1-inch attach EverGuard Polymat il Plates or Drill-Tec Eyehook AccuSeam Plates cover strip is heat welded 1.5- 60-m Cushioning Layer(6 oz/yd2) inch on both sides of the fastener rows One or more layers, EverGuard Polymat min.1.5-inch 5 parts 6-inch o.c.within 6-inch wide Min.18 ga.,type B, Separation Layer(3 oz/ydi)or EverGuard Drill-Tec XHD Fasteners with Drill-Tec 2 in. 5-510. Grade 33 steel EnergyGuard Polyiso per 4 x 4 EverGuard Polymat TPO Double Barbed XHD Plates laps spaced 114-inch o.c.and -90.0 Insulation, ft board Cushioning Layer(6 oz/yd�) sealed with a 1.5-inch heat weld. EnergyGuard Ultra EverGuard TPO Fleece-Back Membrane: Drill-Tec XHD(steel only)or Drill-Tec#14 Min.22 ga.,type B, EverGuard Fasteners(concrete only)with Drill-Tec 2 3/8 in. 6-inch o.c.within min.6-inch 5-511. Grade 33 steel or One o more layers, prelim. TPO Fleece- Barbed XHD Plates or Drill-Tec#15 EHD Fastener wide laps spaced 114-inch o.c. -45.0 min.1.5-inch structrural any combination, attach N/A Back (steel only)or Drill-Tec#14 HD Fastener and sealed with a 1.625-inch concrete Membrane (concrete only)with Drill-Tec 2.4"Barbed Seam heat weld. Plate or Drill-Tec 2.4"Scoop Seam Plate NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 71^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 80 of 156 NNEMO I etc. ATTACHEDEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-1:MECHANICALLY ROOF Insulation(Note 13) Roof Cover(Note 15A) System Deck MDP No. (Note 1) Type Attach Separator Sheet(Optional) Membrane Fasteners(Note 11) Attachment (psf) (Note 5) EverGuard Drill-Tec XHD with Drill-Tec 2 in.Double Barbed type B, Prel Min.22 a., Min.200 psi,min.2- im. TPO Fleece- XHD Plates,Drill-Tec Eyehook AccuSeam Plates 12-inch o.c.within 6-inch wide g 5-512. Grade 33 steel inch thick cellular attach N/A Back or Drill-Tec 2-3/8 in.Barbed XHD Plates or Drill- laps spaced 54-inch o.c.and -45.0 lightweight concrete Membrane Tec#15 EHD Fastener with Drill-Tec 2.4"Barbed sealed with a 1.5-inch heat weld. Seam Plate or Drill-Tec 2.4"Scoop Seam Plate Drill-Tec XHD(steel only)or Drill-Tec#14 Min.22 ga.,type B, EverGuard Fasteners(concrete only)with Drill-Tec 2 3/8 in. 6-inch o.c.within min.6-inch Grade 33 steel a One or more layers, prelim. TPO Fleece- Barbed XHD Plates or Drill-Tec#15 EHD Fastener wide laps spaced 112.5-inch o.c. 5-513. structrural any combination, attach N/A Back (steel only)or Drill-Tec#14 HD Fastener and sealed with a 1.625-inch -60.0 concrete min.1.5-inch Membrane (concrete only)with Drill-Tec 2.4"Barbed Seam heat weld. Plate or Drill-Tec 2.4"Scoop Seam Plate EverGuard Min.22 ga.,type B, Min. psi,min.2- prelim. TPO Fleece- 12-inch o.c.within 6-inch wide 5-514. Grade 33 steel inch thichic k cellular attach N/A Back Drill-Tec XHD with Drill-Tec 2-3/4 in.SXHD Plates laps spaced 54-inch o.c.and -67.5 lightweight concrete Membrane sealed with a 1.5-inch heat weld. Min.200 psi,min.3- EverGuard Fastened through to engage Min.22 ga.,type inch thick Elastizell TPO Fleece- Drill-Tec XHD with Drill-Tec 2 in.Double Barbed steel deck,6-inch o.c.within 6- N/A N/A Back XHD Plates(to engage steel deck) inch wide laps spaced 114-inch -75.0 5-515. BV(0.5%),Grade Lightweight 33 steel Insulating Concrete Membrane o.c.and sealed with a 1.5-inch heat weld. CONCRETETABLE 2j:STEEL OR STRUCTURAL ••• • RECOVER SYSTEM TYPE D-2:INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER An Deck Insulation Layer(s)(Note 13) Base or Anchor Sheet MOP System No. Fasteners Roof Cover (Note 1) Type Attach Base (Note 11) Attach (psf) Min.22 ga.,type B,Grade 33 One or more layers, GAF StormSafe Anchor Note 2(no 12-inch o.c.at min.4-inch laps and 12- EverGuard Freedom TPO/self 5-516. steel or min.2,500 psi Loose-laid recessed inch o.c.in two,equally spaced, -45.0 structrual concrete any combination Sheet(48-inch wide) plate) staggered center rows adhered Min.22 ga.,type B,Grade 33 Note 2(no 18-inch o.c.at min.4-inch laps and 18- 5-517. steel or min.2,500 psi One or more layers, Loose-laid GAF StormSafe Anchor recessed inch o.c.in two,equally spaced, EverGuard Freedom TPO/self -52.5 structrual concrete any combination Sheet(48-inch wide) plate) staggered center rows adhered NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 81 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 1-6-FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psf) (Notes 6,7,8) (Notes 6,7,8) EverGuard Freedom TPO: C-1. Structural Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer of base insulation GAF 2-Part EverGuard Freedom TPO/self -142.5 concrete EnergyGuard Ultra adhered Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard Freedom TPO/self C 2. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch SECUROCK Gypsum- GAF 2-Part adhered -232.5 Fiber Roof Board C-3. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard Freedom TPO/self -382.5 concrete EnergyGuard RN Board adhered Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO/self C-4. concrete 1.5-inch EnergyGuard RH LRF-M Insulation,EnergyGuard HD Polyiso Insulation, LRF-M adhered 97.5 EnergyGuard HD Plus Polyiso Insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard Freedom TPO/self C-5. concrete EnergyGuard Ultra LRF-M followed by Min.0.25-inch SECUROCK Gypsum- LRF-M adhered -232.5 Fiber Roof Board C-6. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard Freedom TPO/self 292 5 concrete EnergyGuard Ultra adhered C 7 Structural Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer of base insulation LRF-XF EverGuard Freedom TPO/self -142.5 concrete EnergyGuard Ultra adhered C 8 Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min.0.25-inch SECUROCK Gypsum- LRF-XF EverGuard Freedom TPO self / -232.5 concrete EnergyGuard Ultra Fiber Roof Board adhered C 9 Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard Freedom TPO/self -382.5 concrete Board adhered C-10. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard Freedom TPO/self -37.5 concrete EnergyGuard RN adhered C-11. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard Freedom TPO/self -37.5 concrete EnergyGuard RN Board adhered Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO/self C-12. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 adhered -37.5 EnergyGuard HD Plus Polyiso Insulation C-13. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard Freedom TPO/self -52.5 concrete I EnergyGuard RN adhered Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO/self C-14. concrete Min. EnergyGuard RH 0B500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 adhered 97.5 EnergyGuard HD Plus Polyiso Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 82 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO/self C-15. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 adhered 97.5 EnergyGuard HD Plus Polyiso Insulation C-16. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or Og500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard Freedom TPO/self -127.5 concrete EnergyGuard RN Board adhered C-17. Structural Min.0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None EverGuard Freedom TPO/self -230.0 concrete adhered Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard Freedom TPO/self C-18. concrete EnergyGuard Ultra OB500 followed by Min.0.25-inch SECUROCK Gypsum- OB500 adhered -232.5 Fiber Roof Board C-19. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layers of base insulation OB500 EverGuard Freedom TPO/self -292.5 concrete EnergyGuard Ultra adhered C-20. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard Freedom TPO/self -347.5 concrete EnergyGuard RN Board adhered C-21. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 in.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard Freedom TPO/self -382.5 concrete EnergyGuard RN Board adhered EverGuard TPO/EverGuard TPO#1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: C 22 Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Hot Asphalt (Optional)Min.0.25-inch DensDeck Prime or Hot asphalt EverGuard TPO/#1121,TPO 3- _45.0 concrete EnergyGuard RN min.7/16-inch OSB Square Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/#1121,TPO 3- C-23. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.5-inch Structodek High GAF 2-Part Square 82.5 Density Fiberboard Roof Insulation C 2q Structural Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO/#1121,TPO 3- 87 5 concrete Gypsum-Fiber Roof Board Square Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or EverGuard TPO/#1121,TPO 3- C-25. concrete EnergyGuard RN or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck or DensDeck Prime GAF 2-Part Square -130.0 Insulfoam EPS C-26. Structural One or more layers,min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/#1121,TPO 3- _180.0 concrete Insulfoam EPS Board Square Structural Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/#1121,TPO 3- C 27. concrete EnergyGuard Ultra GAF 2-Part (Optional)Additional layers of base insulation GAF 2-Part Square -232.5 Additional optional layers base insulation C 28 Structural Min.0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part followed by min.0.25-inch DensDeck Prime or GAF 2-Part EverGuard TPO/#1121,TPO 3- -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum-Fiber Roof Board Square C 29 Structural One or more layers,min.1.5-inch thick,min.2.0 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/#1121,TPO 3- -240.0 concrete Insulfoam EPS Board Square NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 83 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) C-30. Structural Min.2-inch EnergyGuard RA,EnergyGuard RH or GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/#1121,TPO 3- 247 5 concrete EnergyGuard RN Board Square Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/#1121,TPO 3- C-31. concrete EnergyGuard Ultra LRF-M followed by min.0.5-inch Structodek High LRF-M Square 82.5 Density Fiberboard Roof Insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO/#1121,TPO 3- C-32. concrete 1.5-inch EnergyGuard RH LRF-M Insulation,EnergyGuard HD Polyiso Insulation, LRF-M Square 97.5 EnergyGuard HD Plus Polyiso Insulation C-33. Structural Min.1-inch EnergyGuard RH LRF-M (Optional)Additional layer of base insulation LRF-M EverGuard TPO/#1121,TPO 3- -162.5 concrete Square Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/#1121,TPO 3- C-34. concrete EnergyGuard Ultra LRF-M followed by Min.0.25-inch DensDeck Prime or LRF-M Square -232.5 SECUROCK Gypsum-Fiber Roof Board C-35. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard TPO/#1121,TPO 3- 292 5 concrete EnergyGuard Ultra Square C-36. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch DensDeck Prime LRF-XF EverGuard TPO/#1121,TPO 3- -130.0 concrete Square C-37. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layers of base insulation LRF-XF EverGuard TPO/#1121,TPO 3- _232.5 concrete EnergyGuard Ultra Square Additional optional layers base insulation C-38. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min.0.25-inch DensDeck Prime or LRF-XF EverGuard TPO/#1121,TPO 3- -232.5 concrete EnergyGuard Ultra Square SECUROCK Gypsum-Fiber Roof Board C-39. Structural Min.2-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard TPO/#1121,TPO 3- 247 5 concrete Board Square C-40. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO/#1121,TPO 3- -37.5 concrete EnergyGuard RN Square C-41. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO/#1121,TPO 3- -37.5 concrete EnergyGuard RN Gypsum-Fiber Roof Board Square C 42 Min.0.5-inch EnergyGuard RH HD Polyiso Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 EverGuard TPO/#1121,TPO 3- -37.5 concrete 1.5-inch EnergyGuard RH Square EnergyGuard HD Plus Polyiso Insulation C-43. Structural Min.1.5-inch Insulfoam OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/#1121,TPO 3- -45.0 concrete Square C 44 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO/#1121,TPO 3- _45.0 concrete EnergyGuard RN I Square C-45. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/#1121,TPO 3- -52.5 concrete EnergyGuard RN Square NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 84 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/#1121,TPO 3- C-46. concrete EnergyGuard Ultra OB500 followed by min.0.5-inch Structodek High OB500 Square 82.5 Density Fiberboard Roof Insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO/#1121,TPO 3- C-47. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 Square 97.5 EnergyGuard HD Plus Polyiso Insulation C 48 Structural Min.2-inch,min.2.0 pcf,Insulfoam EPS OB500 Min.0.25-inch DensDeck or DensDeck Prime OB500 EverGuard TPO/#1121,TPO 3- -120.0 concrete Square C 49 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/#1121,TPO 3- -127.5 concrete EnergyGuard RN Board Square C-50. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck or DensDeck Prime OBS00 EverGuard TPO/#1121,TPO 3- _130.0 concrete EnergyGuard RN Square Additional optional layers base insulation C-51. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 followed by min.0.25-inch DensDeck Prime or OB500 EverGuard TPO/#1121,TPO 3- -232.5 concrete EnergyGuard Ultra Square SECUROCK Gypsum-Fiber Roof Board C-52. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RN OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO/#1121,TPO 3- _240.0 concrete Gypsum-Fiber Roof Board Square Min.2-inch EnergyGuard Polyiso Insulation, C-53. Structural EnergyGuard RA,EnergyGuard RH or EnergyGuard OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/#1121,TPO 3- -247.5 RN concrete Board Square Structural EverGuard TPO/#1121,TPO 3- C-54. Min.1.5-inch EnergyGuard Ultra OB500 (Optional)Additional layer of base insulation OB500 -270.0 concrete Square C-55. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layers of base insulation OB500 EverGuard TPO/#1121,TPO 3- 292 5 concrete EnergyGuard Ultra I Square C-56. Structural Min.1-inch EnergyGuard Polyiso Insulation, OB500 None N/A EverGuard TPO/#1121,TPO 3- -502.5 concrete EnergyGuard RA Square EverGuard TPO/EverGuard WB181 Bonding Adhesive: C-57. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Hot asphalt (Optional)Additional layer of base insulation Hot asphalt EverGuard TPO/WB181 -135.0 concrete EnergyGuard RN C-58. Structural Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Min.0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO/WB181 -87.5 concrete Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or C-59. concrete EnergyGuard RN or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO/WB181 -130.0 Insulfoam EPS Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-60. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch DensDeck Prime or GAF 2-Part EverGuard TPO/WB181 -232.5 SECUROCK Gypsum-Fiber Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 85 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) C-61. Structural Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer of base insulation GAF 2-Part EverGuard TPO/WB181 -270.0 concrete EnergyGuard Ultra Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso C-62. concrete 1.5-inch EnergyGuard RH LRF-M Insulation,EnergyGuard HD Polyiso Insulation, LRF-M EverGuard TPO/WB181 -97.5 EnergyGuard HD Plus Polyiso Insulation C-63. Structural Min.0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M None N/A EverGuard TPO/WB181 -112.5 concrete Structural C-64. Min.1-inch EnergyGuard RH LRF-M (Optional)Additional layer of base insulation LRF-M EverGuard TPO/W6181 -162.5 concrete Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-65. concrete EnergyGuard Ultra LRF-M followed by min.0.25-inch DensDeck Prime or LRF-M EverGuard TPO/WB181 -232.5 SECUROCK Gypsum-Fiber Roof Board Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-66. LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard TPO/W6181 -292.5 concrete EnergyGuard Ultra Structural C-67. concrete Min.1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch DensDeck Prime LRF-XF EverGuard TPO/W6181 -130.0 Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-68. concrete EnergyGuard Ultra LRF-XF followed by min.0.25-inch DensDeck Prime or LRF-XF EverGuard TPO/WB181 -232.5 SECUROCK Gypsum-Fiber Roof Board Structural Min.1.5-inch EnergyGuard Polyiso Insulation, C-69. concrete EnergyGuard Ultra LRF-XF (Optional)Additional layer of base insulation LRF-XF EverGuard TPO/W6181 -270.0 C-70. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO/WB181 -37.5 concrete EnergyGuard RN C-71. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO/WB181 -37.5 concrete EnergyGuard RN Gypsum-Fiber Roof Board Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso C-72. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OBSOO EverGuard TPO/WB181 -37.5 EnergyGuard HD Plus Polyiso Insulation C-73. Structural Min.1.5-inch Insulfoam OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/WB181 -45.0 concrete Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or C-74. OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO/WB181 -45.0 concrete EnergyGuard RN C-75. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO/WB181 -52.5 concrete EnergyGuard RN Gypsum-Fiber Roof Board Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso C-76. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 EverGuard TPO/WB181 -97.5 EnergyGuard HD Plus Polyiso Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 86 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Min.0.5-inch EnergyGuard RH HD Polyiso Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. C 77. concrete Min. EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 EverGuard TPO/WB181 -97.5 EnergyGuard HD Plus Polyiso Insulation C 78 Structural Min.2-inch,min.2.0 pcf,Insulfoam EPS OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/WB181 -120.0 concrete C 79 Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/WB181 -130.0 concrete EnergyGuard RN C-80. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/WB181 -135.0 concrete EnergyGuard RN C-81. Structural Min.1-inch EnergyGuard RA OB500 None N/A EverGuard TPO/WB181 -215.0 concrete Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C 82. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch DensDeck Prime or OB500 EverGuard TPO/WB181 -232.5 SECUROCK Gypsum-Fiber Roof Board Structural C-83. concrete Min.1.5-inch EnergyGuard Ultra OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO/WB181 -270.0 C-84. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layers of base insulation OB500 EverGuard TPO/WB181 -292.5 concrete EnergyGuard Ultra EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Ir- C-85. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Hot Asphalt (Optional)Min.0.25-inch DensDeck Prime Hot asphalt EverGuard TPO/TPO 6-Square, -45.0 concrete EnergyGuard RN TPO 3-Square Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/TPO 6-Square, C-86. concrete EnergyGuard RN or min.1.5-inch thick,min.1.25 pcf GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO 3-Square -45.0 Insulfoam EPS Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/TPO 6-Square, C 87. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.5-inch Structodek High GAF 2-Part TPO 3-Square 82.5 Density Fiberboard Roof Insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/TPO 6-Square, C 88. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch DensDeck Prime or GAF 2-Part TPO 3-Square -232.5 SECUROCK Gypsum-Fiber Roof Board C 89 Structural Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer of base insulation GAF 2-Part EverGuard TPO/TPO 6-Square, -270.0 concrete I EnergyGuard Ultra TPO 3-Square Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/TPO 6-Square, C-90. concrete EnergyGuard Ultra LRF-M followed by min.0.5-inch Structodek High LRF-M TPO 3-Square 82.5 Density Fiberboard Roof Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 87 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO/TPO 6-Square, C-91. concrete 1.5-inch EnergyGuard RH LRF-M Insulation,EnergyGuard HD Polyiso Insulation, LRF-M TPO 3-Square 97.5 EnergyGuard HD Plus Polyiso Insulation C 92 Structural Min.1-inch EnergyGuard RH LRF-M (Optional)Additional layer of base insulation LRF-M EverGuard TPO/TPO 6-Square, -162.5 concrete TPO 3-Square Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/TPO 6-Square, C-93. concrete EnergyGuard Ultra LRF-M followed by min.0.25-inch DensDeck Prime or LRF-M TPO 3-Square -232.5 SECUROCK Gypsum-Fiber Roof Board C-94. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard TPO/TPO 6-Square, -240.0 concrete EnergyGuard Ultra TPO 3-Square C-95. Structural Min.0.5-inch EnergyGuard RH LRF-M Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-M EverGuard TPO/TPO 6-Square, -360.0 concrete Board TPO 3-Square C-96. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch DensDeck Prime or SECUROCK LRF-XF EverGuard TPO/TPO 6-Square, -45.0 concrete Gypsum-Fiber Roof Board TPO 3-Square Additional optional layers base insulation C-97. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min.0.25-inch DensDeck Prime or LRF-XF EverGuard TPO/TPO 6-Square, -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum-Fiber Roof Board TPO 3-Square C 98 Structural Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer of base insulation LRF-XF EverGuard TPO/TPO 6-Square, -270.0 concrete EnergyGuard Ultra TPO 3-Square C 99 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO/TPO 6-Square, -37.5 concrete EnergyGuard RN TPO 3-Square C-100. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO/TPO 6-Square, -37.5 concrete EnergyGuard RN Gypsum-Fiber Roof Board TPO 3-Square C-101. Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. OB500 Min.0.5-inch EnergyGuard RH HD Polyiso Insulation,EnergyGuard HD Polyiso Insulation, OB500 EverGuard TPO/TPO 6-Square, -37.5 concrete 1.5-inch EnergyGuard RH TPO 3-Square EnergyGuard HD Plus Polyiso Insulation Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/TPO 6-Square, C-102. concrete EnergyGuard RN,min.2-inch,min.2.0 pcf,Insulfoam OB500 Gypsum-Fiber Roof Board OB500 TPO 3-Square -45.0 EPS or min.1.5-inch Insulfoam C-103. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OBS00 (Optional)Additional layer of base insulation OBS00 EverGuard TPO/TPO 6-Square, -45.0 concrete EnergyGuard RN TPO 3-Square C-104. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/TPO 6-Square, -45.0 concrete EnergyGuard RN TPO 3-Square Additional optional layers base insulation C-105. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 followed by OB500 EverGuard TPO/TPO 6-Square, 82 5 concrete EnergyGuard Ultra Min.0.5-inch Structodek High Density TPO 3-Square Fiberboard Roof Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 88 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO/TPO 6-Square, C-106. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 TPO 3-Square 97.5 EnergyGuard HD Plus Polyiso Insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO/TPO 6-Square, C-107. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 TPO 3-Square 97.5 EnergyGuard HD Plus Polyiso Insulation C-108. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/TPO 6-Square, -127.5 concrete EnergyGuard RN Board TPO 3-Square Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/TPO 6-Square, C-109. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch DensDeck Prime or OB500 TPO 3-Square -232.5 SECUROCK Gypsum-Fiber Roof Board C-110. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layers of base insulation OB500 EverGuard TPO/TPO 6-Square, -240.0 concrete EnergyGuard Ultra TPO 3-Square Structural EverGuard TPO/TPO 6-Square, C-111. concrete Min.1.5-inch EnergyGuard Ultra OB500 (Optional)Additional layer of base insulation OB500 TPO 3-Square -270.0 C-112. Structural Min.1-inch EnergyGuard RH OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/TPO 6-Square, -502.5 concrete Board TPO 3-Square EverGuard TPO/EverGuard TPO Quick Spray or EverGuard TPO Quick Spray LV SO: Structural EverGuard TPO/TPO QSA or TPO C-113. concrete Min.0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layers of base insulation GAF 2-Part QSA LV50 82.5 Structural C-114. Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer of base insulation GAF 2-Part EverGuard TPO/TPO QSA LV50 -270.0 concrete C-115. Structural Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Min.0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO/TPO QSA or TPO 87 5 concrete QSA LV50 Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or EverGuard TPO/TPO QSA or TPO C-116. concrete EnergyGuard RN or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck Prime GAF 2-Part QSA LV50 -130.0 Insulfoam EPS C-117. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part Additional optional layers base insulation GAF 2-Part EverGuard TPO/TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime C-118. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part Additional optional layers base insulation GAF 2-Part EverGuard TPO/TPO QSA -232.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime C-119. Structural Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/TPO QSA LV50 -87.5 concrete Board Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.25-inch SECUROCK Gypsum-Fiber Roof C-120. concrete EnergyGuard Ultra Polyiso Insulation,EnergyGuard GAF 2-Part Board GAF 2-Part EverGuard TPO/TPO QSA -90.0 RA,or EnergyGuard RN NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 89 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) C-121. Structural One or more layers,min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/TPO QSA LV50 -180.0 concrete Insulfoam EPS Board Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-122. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard TPO/TPO QSA LV50 -232.5 Fiber Roof Board Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-123. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard TPO/TPO QSA LV50 -232.5 Fiber Roof Board C-124. Structural One or more layers,min.1.5-inch thick,min.2.0 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/TPO QSA LV50 -240.0 concrete Insulfoam EPS Board C-125. Structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard TPO/TPO QSA -82.5 concrete Structural C-126. Min.0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard TPO/TPO QSA LV50 -292.5 concrete C-127. Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. LRF-M Min.0.5-inch EnergyGuard HD Polyiso LRF-M EverGuard TPO/TPO QSA or TPO g7 5 concrete 1.5-inch EnergyGuard RH Insulation QSA LV50 C-128. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M Additional optional layers base insulation LRF-M EverGuard TPO/TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime C-129. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M Additional optional layers base insulation LRF-M EverGuard TPO/TPO QSA -232.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime C-130. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-M EverGuard TPO/TPO QSA -97.5 concrete EnergyGuard Ultra Board Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation C-131. concrete EnergyGuard Ultra LRF-M followed by Min.0.25-inch SECUROCK Gypsum- LRF-M EverGuard TPO/TPO QSA LV50 -232.5 Fiber Roof Board C-132. Structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layers of base insulation LRF-XF EverGuard TPO/TPO QSA or TPO 82 5 concrete QSA LV50 C-133. Structural Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer of base insulation LRF-XF EverGuard TPO/TPO QSA LV50 -270.0 concrete C-134. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch DensDeck Prime LRF-XF EverGuard TPO/TPO QSA or TPO -130.0 concrete QSA LV50 C-135. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-XF Additional optional layers base insulation LRF-XF EverGuard TPO/TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime C-136. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-XF Additional optional layers base insulation LRF-XF EverGuard TPO/TPO QSA -232.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 90 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.25-inch SECUROCK Gypsum-Fiber Roof C-137. concrete EnergyGuard Ultra Polyiso Insulation or EnergyGuard LRF-XF Board R LRF-XF EverGuard TPO/TPO QSA -90.0 Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation C-138. concrete EnergyGuard Ultra LRF-XF followed by min.0.25-inch SECUROCK Gypsum- LRF-XF EverGuard TPO/TPO QSA LV50 -232.5 Fiber Roof Board Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation C-139. concrete EnergyGuard Ultra LRF-XF followed by min.0.25-inch SECUROCK Gypsum- LRF-XF EverGuard TPO/TPO QSA LV50 -232.5 Fiber Roof Board Structural EverGuard TPO/TPO QSA or TPO C-140. concrete Min.1-inch EnergyGuard RA OB500 (Optional)Additional layer of base insulation OB500 QSA LV50 -45.0 C-141. Structural Min.1-inch EnergyGuard RA OB500 None N/A EverGuard TPO/TPO QSA or TPO -75.0 concrete QSA LV50 C-142. Structural Min.0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layers of base insulation OB500 EverGuard TPO/TPO QSA -82.5 concrete C-143. Structural Min.0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layers of base insulation OB500 EverGuard TPO/TPO QSA LV50 -292.5 concrete C-144. Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. OB500 Min.0.5-inch EnergyGuard HD Polyiso OB500 EverGuard TPO/TPO QSA or TPO 97 5 concrete 1.5-inch EnergyGuard RH Insulation QSA LV50 C-145. Structural Min.1.5-inch Insulfoam OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/TPO QSA or TPO -45.0 concrete QSA LV50 C-146. Structural Min.2-inch Insulfoam I OB500 Min.0.25-inch DensDeck Prime 0B500 EverGuard TPO/TPO QSA -120.0 concrete C-147. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime 0B500 EverGuard TPO/TPO QSA or TPO -135.0 concrete EnergyGuard RN QSA LV50 C-148. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 Additional optional layers base insulation OB500 EverGuard TPO/TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime C-149. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 Additional optional layers base insulation OB500 EverGuard TPO/TPO QSA -232.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime C-150. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RN OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/TPO QSA -240.0 concrete C-151. Structural Min.1.5-inch Insulfoam 0B500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/TPO QSA or TPO -45.0 concrete Board QSA LV50 Min.0.5-inch EnergyGuard Polyiso Insulation, C-152. Structural EnergyGuard Ultra, min.1-inch EnergyGuard RA, OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/TPO QSA -97.5 concrete EnergyGuard RH or EnergyGuard RN or min.2-inch Board Insulfoam I NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 91 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) C-153. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/TPO QSA LV50 -127.5 concrete EnergyGuard RN Board Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-154. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch SECUROCK Gypsum- OB500 EverGuard TPO/TPO QSA LV50 -232.5 Fiber Roof Board C-155. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RN OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/TPO QSA LV50 -240.0 concrete Board Structural Min.2-inch EnergyGuard Polyiso Insulation, Min.0.25-inch SECUROCK Gypsum-Fiber Roof C-156. concrete RN EnergyGuard RA,EnergyGuard RH or EnergyGuard OB500 Board OB500 EverGuard TPO/TPO QSA LV50 -247.5 C-157. Structural Min.1-inch EnergyGuard RH OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/TPO QSA LV50 -502.5 concrete Board EverGuard TPO in FastLayn TPO Adhesive: C-158. Structural Min.1.5-inch EnergyGuard RA hot asphalt (Optional)Min.0.25-inch DensDeck Prime hot asphalt EverGuard TPO/FastLayn TPO -45.0 concrete Adhesive C-159. Structural Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Min.0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO/FastLayn TPO 87 5 concrete Gypsum-Fiber Roof Board Adhesive Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.5-inch EnergyGuard HD Polyiso EverGuard TPO/FastLayn TPO C-160. concrete EnergyGuard Ultra Polyiso Insulation,EnergyGuard GAF 2-Part Insulation GAF 2-Part Adhesive -90.0 RA,or EnergyGuard RN Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or EverGuard TPO FastLayn TPO C-161. concrete EnergyGuard RN or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck Prime GAF 2-Part Adhesive -130.0 Insulfoam EPS C-162. Structural One or more layers,min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/FastLayn TPO _180.0 concrete Insulfoam EPS Board Adhesive C-163. Structural Min.0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layers of base insulation GAF 2-Part EverGuard TPO/FastLayn TPO concrete -232.5 Adhesive Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/FastLayn TPO C-164. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch DensDeck Prime or GAF 2-Part Adhesive -232.5 SECUROCK Gypsum-Fiber Roof Board C-165. Structural One or more layers,min.1.5-inch thick,min.2.0 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/FastLayn TPO -240.0 concrete Insulfoam EPS Board Adhesive C-166. Structural Min.2-inch EnergyGuard RA,EnergyGuard RH or GAF 2-Part Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part EverGuard TPO/FastLayn TPO 247 5 concrete EnergyGuard RN Board Adhesive Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.5-inch EnergyGuard HD Polyiso EverGuard TPO/FastLayn TPO C-167. concrete EnergyGuard Ultra Polyiso Insulation,EnergyGuard LRF-M Insulation LRF-M Adhesive 90.0 RA,or EnergyGuard RN NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 MEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 92 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) C-168. Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. LRF-M Min.0.5-inch EnergyGuard HD Polyiso LRF-M EverGuard TPO/FastLayn TPO -97.5 concrete 1.5-inch EnergyGuard RH Insulation Adhesive Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/FastLayn TPO C-169. concrete EnergyGuard Ultra LRF-M followed by Min.0.25-inch DensDeck Prime or LRF-M Adhesive -232.5 SECUROCK Gypsum-Fiber Roof Board C-170. Structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard TPO/FastLayn TPO -292.5 concrete Adhesive Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.5-inch EnergyGuard HD Polyiso EverGuard TPO/FastLayn TPO C-171. concrete EnergyGuard Ultra Polyiso Insulation or EnergyGuard LRF-XF Insulation LRF-XF Adhesive -90.0 C-172. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch DensDeck Prime LRF-XF EverGuard TPO/FastLayn TPO -130.0 concrete Adhesive C-173. Structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layers of base insulation LRF-XF EverGuard TPO/FastLayn TPO -232.5 concrete Adhesive C-174. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation LRF-XF followed by min.0.25-inch DensDeck Prime or LRF-XF EverGuard TPO/FastLayn TPO _232.5 concrete EnergyGuard Ultra Adhesive SECUROCK Gypsum-Fiber Roof Board C-175. Structural Min.2-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF EverGuard TPO/FastLayn TPO -247.5 concrete Board Adhesive C-176. Structural Min.1.5-inch Insulfoam EPS OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/FastLayn TPO -45.0 concrete Adhesive C-177. Structural Min.1-inch EnergyGuard RA OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO/FastLayn TPO -45.0 concrete Adhesive C-178. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/FastLayn TPO _52.5 concrete EnergyGuard RN Adhesive Min.0.5-inch EnergyGuard Polyiso Insulation, C-179. Structural EnergyGuard Ultra Polyiso Insulation,EnergyGuard OB500 Min.0.5-inch EnergyGuard HD Polyiso OBS00 EverGuard TPO/FastLayn TPO 90 0 concrete RA,or EnergyGuard RN Insulation Adhesive C-180. Structural Min.1.5-inch EnergyGuard RH OB500 Min.0.5-inch EnergyGuard HD Polyiso OB500 EverGuard TPO/FastLayn TPO 97 5 concrete Insulation Adhesive C-181. Structural Min.2-inch,min.2.0 pd,Insulfoam EPS OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/FastLayn TPO -120.0 concrete Adhesive C-182. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/FastLayn TPO -127.5 concrete EnergyGuard RN Board Adhesive C-183. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 Min 025-inch DensDeck Prime OB500 EverGuard TPO/FastLayn TPO -130.0 concrete EnergyGuard RN or Min.1-inch Foamular 250 . . Adhesive NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 93 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO/FastLayn TPO C-184. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch DensDeck Prime or OB500 Adhesive -232.5 SECUROCK Gypsum-Fiber Roof Board C-185. Structural Min.1.5-inch EnergyGuard RA or EnergyGuard RN OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO/FastLayn TPO -240.0 concrete Gypsum-Fiber Roof Board Adhesive C-186. Structural Min.2-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 EverGuard TPO/FastLayn TPO 247 5 concrete EnergyGuard RN Board Adhesive C-187. Structural Min.0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layers of base insulation OB500 EverGuard TPO/FastLayn TPO 292 5 concrete Adhesive Structural (Optional)Min.1.5-inch EnergyGuard Polyiso Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO FastLayn TPO C-188. concrete Insulation,EnergyGuard Ultra Polyiso Insulation or OB500 Board or min.0.5-inch EnergyGuard HD Polyiso OB500 Adhesive -270.0 EnergyGuard RA Insulation C-189. Structural Min.1.5-inch EnergyGuard Polyiso Insulation or OB500 None N/A EverGuard TPO/FastLayn TPO -375.0 concrete EnergyGuard RA Adhesive Triposite Roofing System: Structural Min.2-inch EnergyGuard Polyiso Insulation or C-190. concrete EnergyGuard Ultra or min.1.5-inch EnergyGuard RA, Hot Asphalt (Optional)Additional layers of base insulation Hot asphalt Triposite System. Note 15C -172.5 (primed) EnergyGuard RN EverGuard TPO Fleece-Back Membrane in Hot Asphalt: Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH, EverGuard TPO Fleece-Back C-191. concrete Hot Asphalt Min.0.25-inch DensDeck Hot asphalt -45.0 (primed) EnergyGuard RN or EnergyGuard Ultra Membrane/Hot asphalt Structural EverGuard TPO Fleece-Back C-192. concrete Min.1-inch EnergyGuard RH Hot asphalt None N/A Membrane/Hot asphalt -470.0 (primed) C-193. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH, OB500 Min.0.25-inch DensDeck OB500 EverGuard TPO Fleece-Back -45.0 concrete EnergyGuard RN or EnergyGuard Ultra Membrane/Hot asphalt EverGuard TPO Fleece-Back Membrane in EverGuard WB181 Bonding Adhesive: Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-194. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/ Flee -232.5 SECUROCK Gypsum-Fiber Roof Board Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO Fleece-Back C-195. concrete 1.5-inch EnergyGuard RH LRF-M Insulation,EnergyGuard HD Polyiso Insulation, LRF-M Membrane/WB181 -97.5 EnergyGuard HD Plus Polyiso Insulation Additional optional layers base insulation Structural Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back C-196. concrete EnergyGuard Ultra LRF-M followed by min. inch DensDeck Prime or LRF-M Membrane/WB181 -232.5 SECUROCK Gypsum-Fiber Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 94 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) C-197. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M (Optional)Additional layers of base insulation LRF-M EverGuard TPO Fleece-Back -292.5 concrete EnergyGuard Ultra Membrane/WB181 Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-198. concrete EnergyGuard Ultra LRF-XF followed by min.0.25-inch DensDeck Prime or LRF-XF Membrane/WB181 -232.5 SECUROCK Gypsum-Fiber Roof Board C-199. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO Fleece-Back _37.5 concrete EnergyGuard RN Membrane/WB181 C-200. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO Fleece-Back -37.5 concrete EnergyGuard RN Gypsum-Fiber Roof Board Membrane/WB181 Min. inch EnergyGuard RH HD Polyiso Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. EverGuard TPO Fleece-Back C-201. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard His Polyiso Insulation, OB500 Membrane/WB181 -37.5 EnergyGuard HD Plus Polyiso Insulation C-202. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO Fleece-Back -52.5 concrete EnergyGuard RN Gypsum-Fiber Roof Board Membrane/WB181 Structural Min.0.5-inch EnergyGuard Polyiso Insulation or min. Min.0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO Fleece-Back C-203. concrete 1.5-inch EnergyGuard RH OB500 Insulation,EnergyGuard HD Polyiso Insulation, OB500 Membrane/WB181 -97.5 EnergyGuard HD Plus Polyiso Insulation C 204 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO Fleece-Back -127.5 concrete EnergyGuard RN Membrane/WB181 C-205. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 (Optional)Additional layers base insulation OB500 EverGuard TPO Fleece-Back -225.0 concrete EnergyGuard RN Membrane/WB181 Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-206. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch DensDeck Prime or OB500 Membrane/WB181 -232.5 SECUROCK Gypsum-Fiber Roof Board Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO Fleece-Back -240.0 C-207. concrete EnergyGuard RN Gypsum-Fiber Roof Board I Membrane/WB181 C-208. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layers of base insulation OB500 EverGuard TPO Fleece-Back 292 5 concrete EnergyGuard Ultra Membrane/WB181 EverGuard TPO Fleece-Back Membrane in LRF Adhesive M or LRF Adhesive O: C-209. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part Additional optional layers base insulation GAF 2-Part EverGuard TPO Fleece-Back -37.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime Membrane/LRF-M,12-inch o.c. C-210. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part Additional optional layers base insulation GAF 2-Part EverGuard TPO Fleece-Back -45.0 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime Membrane/LRF-O,12-inch o.c. Additional optional layers base insulation EverGuard TPO Fleece-Back Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-211. concrete EnergyGuard Ultra GAF 2-Part followed by min.0.25-inch SECUROCK Gypsum- GAF 2-Part Membrane/LRF-M or LRF-O,12- -45.0 Fiber Roof Board inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 95 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back C-212. concrete EnergyGuard Ultra GAF 2-Part (Optional)Additional layers base insulation GAF 2-Part Membrane/LRF-M or LRF-O,12- -60.0 inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back C-213. EnergyGuard Ultra,EnergyGuard RH,EnergyGuard GAF 2-Part followed by min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/LRF-M or LRF-O,4- -180.0 concrete RN I SECUROCK Gypsum-Fiber Roof Board inch o.c. Structural Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back C-214. concrete Gypsum-Fiber Roof Board GAF 2-Part None N/A Membrane/LRF-M or LRF-O,4- -195.0 inch o.c. Structural EverGuard TPO Fleece-Back C-215. concrete (Optional)Min.1-inch EnergyGuard RA LRF-M Min.1.75-inch ACFoam Composite/GB LRF-M Membrane/LRF-M,12-inch o.c. -37.5 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH, Min.0.25-inch Temple Green Glass Primed EverGuard TPO Fleece-Back C-216. concrete EnergyGuard RN LRF-M Roof Board LRF-M Membrane/LRF-M or LRF-O,12- -37.5 inch o.c. C-217. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH. LRF-M Min.0.25-inch DensDeck Prime LRF-M EverGuard TPO Fleece-Back -37.5 concrete EnergyGuard RN Membrane/LRF-M,12-inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-218. LRF-M followed by LRF-M -37.5 concrete EnergyGuard Ultra Min.0.25-inch DensDeck Prime Membrane/LRF-M,12-inch o.c. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or EverGuard TPO Fleece-Back C-219. concrete EnergyGuard RN LRF-M (Optional)Additional layers base insulation LRF-M Membrane/LRF-M or LRF-O,12- -45.0 inch o.c. C-220. Structural (Optional)Min.1-inch EnergyGuard RA LRF-M Min.1.75-inch ACFoam Composite/GB LRF-M EverGuard TPO Fleece-Back -45.0 concrete Membrane/LRF-O,12-inch o.c. C-221. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH. LRF-M Min.0.25-inch DensDeck Prime LRF-M EverGuard TPO Fleece-Back -45.0 concrete EnergyGuard RN Membrane/LRF-O,12-inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-222. LRF-M followed by LRF-M -45.0 concrete EnergyGuard Ultra Min.0.25-inch DensDeck Prime Membrane/LRF-0,12-inch o.c. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH. Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back C-223. concrete EnergyGuard RN LRF-M Board LRF-M Membrane/LRF-M or LRF-0,12- -45.0 inch o.c. Additional optional layers base insulation EverGuard TPO Fleece-Back Structural Min.0.5-inch EnergyGuard Polyiso Insulation, followed by C-224. concrete EnergyGuard Ultra LRF-M Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-M Membrane/LRF-M or LRF-O,12- -45.0 inch o.c. Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 96 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back C-225. concrete EnergyGuard Ultra LRF-M (Optional)Additional layers base insulation LRF-M Membrane/LRF-M or LRF-O,12- -60.0 inch o.c. Structural Min.1.5-inch EnergyGuard Polyiso Insulation, Min.0.25-inch DensDeck Prime or SECUROCK LRF-M EverGuard TPO Fleece-Back -67.5 C-226. concrete EnergyGuard RN,EnergyGuard RM LRF-M Gypsum-Fiber Roof Board Membrane/LRF-M,12-inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back C-227. EnergyGuard Ultra,EnergyGuard RH,EnergyGuard LRF-M followed by min.0.25-inch DensDeck Prime or LRF-M Membrane/LRF-M or LRF-O,4- -180.0 concrete RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Structural Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back C-228. concrete Gypsum-Fiber Roof Board LRF-M None N/A Membrane/LRF-M or LRF-O,4- -195.0 inch o.c. C 229 Structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layers base insulation LRF-M EverGuard TPO Fleece-Back -210.0 concrete Membrane/LRF-M,4-inch o.c. C-230. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-XF Additional optional layers base insulation LRF-XF EverGuard TPO Fleece-Back -37.5 concrete EnergyGuard Ultra followed by min.0.25-inch DensDeck Prime Membrane/LRF-M,12-inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-231. concrete EnergyGuard Ultra LRF-XF followed by min.0.25-inch DensDeck Prime LRF-XF Membrane/LRF-O,12-inch o.c. -45.0 Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-232. concrete EnergyGuard Ultra LRF-XF followed by min.0.25-inch SECUROCK Gypsum- LRF-XF Membrane/LRF-M or LRF-0,12- -45.0 Fiber Roof Board inch o.c. EverGuard TPO Fleece-Back Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-233. concrete EnergyGuard Ultra LRF-XF (Optional)Additional layers base insulation LRF-XF Membrane/LRF-M or LRF-0,12- -60.0 inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back ns C-234. concrete EnergyGuard Ultra or EnergyGuard ns LRF-XF followed by min.0.25-inch DensDeck Prime or LRF-XF Membrane/LRF-M or LRF-0,4- -180.0 SECUROCK Gypsum-Fiber Roof Board inch o.c. Structural Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back C-235. concrete Gypsum-Fiber Roof Board LRF-XF None N/A Membrane/LRF-M or LRF-O,4- -195.0 inch o.c. Structural EverGuard TPO Fleece-Back C-236. concrete (Optional)Min.1-inch EnergyGuard RA OBS00 Min.1.75-inch ACFoam Composite/GB OBS00 Membrane/LRF-M,12-inch o.c. -37.5 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH, Min.0.25-inch Temple Green Glass Primed EverGuard TPO Fleece-Back C-237. concrete EnergyGuard RN OB500 Roof Board OB500 Membrane/LRF-M or LRF-O,12- -37.5 inch o.c. C 238 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH. OBS00 Min.0.25-inch DensDeck Prime 0B500 EverGuard TPO Fleece-Back -37.5 concrete EnergyGuard RN Membrane/LRF-M,12-inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 97 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-239. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch DensDeck Prime OB500 Membrane/LRF-M,12-inch o.c. -37.5 C-240. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH, OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO Fleece-Back -37.5 concrete EnergyGuard RN Gypsum-Fiber Roof Board Membrane/LRF-0,12-inch o.c. EverGuard TPO Fleece-Back Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH or C-241. concrete EnergyGuard RN OB500 (Optional)Additional layers base insulation OB500 Membrane/LRF-M or LRF-O,12- -45.0 inch o.c. C-242. Structural EverGuard TPO Fleece-Back (Optional)Min.1-inch EnergyGuard RA OB500 Min.1.75-inch ACFoam Composite/GB OB500 concrete Membrane/LRF-0,12-inch o.c. -45.0 C-243. Structural Min.1-inch EnergyGuard RA,EnergyGuard RH. OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO Fleece-Back -45.0 concrete EnergyGuard RN Membrane/LRF-0,12-inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C 244. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch DensDeck Prime OB500 Membrane/LRF-O,12-inch o.c. -45.0 Structural Min.1-inch EnergyGuard RA,EnergyGuard RH. Min.0.25-inch SECUROCK Gypsum-Fiber Roof EverGuard TPO Fleece-Back C-245. concrete EnergyGuard RN OB500 Board OB500 Membrane/LRF-M or LRF-0,12- -45.0 inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece-Back C-246. concrete EnergyGuard Ultra OB500 followed by min.0.25-inch SECUROCK Gypsum- OB500 Membrane/LRF-M or LRF-0,12- -45.0 Fiber Roof Board inch o.c. C 247 Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH, OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO Fleece-Back -45.0 concrete I EnergyGuard RN Membrane/LRF-0,12-inch o.c. C-248. Structural Min.1.5-inch EnergyGuard RA,EnergyGuard RH, OB500 Min.0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO Fleece-Back -45.0 concrete EnergyGuard RN Gypsum-Fiber Roof Board Membrane/LRF-0,12-inch o.c. C-249. Structural Min.1.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layer of base insulation OB500 EverGuard TPO Fleece-Back -60.0 concrete EnergyGuard Ultra Membrane/LRF-0,12-inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back C-250. concrete EnergyGuard Ultra OB500 (Optional)Additional layers base insulation OB500 Membrane/LRF-M or LRF-O,12- -60.0 inch o.c. Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back C-251. EnergyGuard Ultra,EnergyGuard RH,EnergyGuard OB500 followed by min.0.25-inch DensDeck Prime or OB500 Membrane/LRF-M or LRF-O,4- -180.0 concrete RN SECUROCK Gypsum-Fiber Roof Board inch o.c. Structural Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back C-252. concrete Gypsum-Fiber Roof Board OB500 None N/A Membrane/LRF-M or LRF-0,4- -195.0 inch o.c. EverGuard TPO Fleece-Back Membrane in Spatter Applications: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization H32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 98 of 156 ------ TABLE 3A:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) NNEMO I etc. OPTIONSSYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER REFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Attach Type Attach Roof Cover(Note 15) (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back C-253. concrete EnergyGuard Ultra GAF 2-Part (Optional)Additional layers base insulation GAF 2-Part Membrane/GAF 2-Part(spatter), -180.0 LRF-XF(spatter)or OBS00(spatter) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back C-254. EnergyGuard Ultra,EnergyGuard RH,EnergyGuard GAF 2-Part followed by min.0.25-inch DensDeck Prime or GAF 2-Part Membrane/GAF 2-Part(spatter), -180.0 concrete RN I SECUROCK Gypsum-Fiber Roof Board LRF-XF(spatter)or OB500(spatter) EverGuard TPO Fleece-Back Structural Min.0.25-inch DensDeck Prime or SECUROCK C-255. concrete Gypsum-Fiber Roof Board GAF 2-Part None N/A Membrane/GAF 2-Part(spatter), -195.0 LRF-XF(spatter)or OB500(spatter) EverGuard TPO Fleece-Back Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-256. concrete EnergyGuard Ultra LRF-M (Optional)Additional layers base insulation LRF-M Membrane/GAF 2-Part(spatter), -180.0 LRF-XF(spatter)or OB500(spatter) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back C-257. EnergyGuard Ultra,EnergyGuard RH,EnergyGuard LRF-M followed by min.0.25-inch DensDeck Prime or LRF-M Membrane/GAF 2-Part(spatter), -180.0 concrete RN SECUROCK Gypsum-Fiber Roof Board LRF-XF(spatter)or OBS00(spatter) EverGuard TPO Fleece-Back Structural Min.0.25-inch DensDeck Prime or SECUROCK C-258. concrete Gypsum-Fiber Roof Board LRF-M None N/A Membrane/GAF 2-Part(spatter), -195.0 LRF-XF(spatter)or OBS00(spatter) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back C-259. concrete EnergyGuard Ultra LRF-XF (Optional)Additional layers base insulation LRF-XF Membrane/GAF 2-Part(spatter), -180.0 LRF-XF(spatter)or OB500(spatter) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back C-260. concrete EnergyGuard Ultra or EnergyGuard RH LRF-XF followed by min.0.25-inch DensDeck Prime or LRF-XF Membrane/GAF 2-Part(spatter), -180.0 SECUROCK Gypsum-Fiber Roof Board LRF-XF(spatter)or OB500(spatter) EverGuard TPO Fleece-Back Structural Min.0.25-inch DensDeck Prime or SECUROCK C-261. concrete Gypsum-Fiber Roof Board LRF-XF None N/A Membrane/GAF 2-Part(spatter), -195.0 LRF-XF(spatter)or OB500(spatter) EverGuard TPO Fleece-Back Structural Min.0.5-inch EnergyGuard Polyiso Insulation, C-262. concrete EnergyGuard Ultra 0B500 (Optional)Additional layers base insulation OBS00 Membrane/GAF 2-Part(spatter), -180.0 LRF-XF(spatter)or OB500(spatter) Structural Min.0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece-Back C-263. EnergyGuard Ultra,EnergyGuard RH,EnergyGuard OB500 followed by min.0.25-inch DensDeck Prime or OB500 Membrane/GAF 2-Part(spatter), -180.0 concrete RN SECUROCK Gypsum-Fiber Roof Board LRF-XF(spatter)or OBS00(spatter) Structural Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece-Back C 264. concrete Gypsum-Fiber Roof Board OB500 None N/A Membrane/GAF 2-Part(spatter), -195.0 LRF-XF(spatter)or OBS00(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization H32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 99 of 156 NNEMO I etc. OPTIONSTABLE 313:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED BASE AND CAP PLY REFER To NOTE 16 FOR VAPOR BARRIER System Deck Base Insulation Layer777- Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) 7 Asphalt-Applied Base Ply: Structural EnergyGuard Polyiso Insulation, GAF 2-Part, Min.0.25-inch SECUROCK GAF 2-Part, Ruberoid 20 Smooth EverGuard TPO Fleece-Back Membrane C-265. EnergyGuard RH,EnergyGuard RM or LRF-M or LRF-M or -60.0 concrete EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 hot asphalt /LRF-O,12-inch o.c. EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, EverGuard TPO Fleece-Back Membrane C-266. Structural EnergyGuard RH,EnergyGuard RM or LRF-M or Min.0.25-inch SECUROCK LRF-M or Ruberoid 20 Smooth /hot asphalt,GAF 2-Part(spatter),LRF- -180.0 concrete EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 /hot asphalt XF(spatter)or OB500(spatter)or LRF- 0,4-inch o.c. C-267. Structural EnergyGuard Polyiso Insulation or LRF-XF Min.0.25-inch SECUROCK LRF-XF Ruberoid 20 Smooth EverGuard TPO Fleece-Back Membrane -60.0 concrete EnergyGuard RH Gypsum-Fiber Roof Board /hot asphalt /LRF-O,12-inch o.c. EverGuard TPO Fleece-Back Membrane Structural EnergyGuard Polyiso Insulation or Min.0.25-inch SECUROCK Ruberoid 20 Smooth /hot asphalt,GAF 2-Part(spatter)or C-268. concrete EnergyGuard RH LRF-XF Gypsum-Fiber Roof Board LRF-XF hot asphalt OB500(spatter)GAF 2-Part(spatter), -180.0 LRF-XF(spatter)or OB500(spatter)or LRF-O,4-inch o.c. Torch-Applied Base Ply: EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, Ruberoid HW 25 C-269. Structural EnergyGuard RH,EnergyGuard RM or LRF-M or Min.um-Finch Roof Board LRF-M or Smooth/torch- EverGuard TPO Fleece-Back Membrane -60.0 concrete EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 applied /LRF-O,12-inch o.c. EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, Ruberoid HW 25 EverGuard TPO Fleece-Back Membrane Structural Min.0.25-inch SECUROCK /hot asphalt,GAF 2-Part(spatter),LRF- C-270. EnergyGuard RH,EnergyGuard RM or LRF-M or LRF-M or Smooth/torch- -180.0 concrete EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 applied XF(spatter)or OB500(spatter)or LRF- 0,4-inch o.c. Structural EnergyGuard Polyiso Insulation or Min.0.25-inch SECUROCK Ruberoid HW 25 EverGuard TPO Fleece-Back Membrane C-271. concrete EnergyGuard RH LRF-XF Gypsum-Fiber Roof Board LRF-XF Smooth/torch- /LRF-O,12-inch o.c. -60.0 applied Ruberoid HW 25 EverGuard TPO Fleece-Back Membrane C 272 Structural EnergyGuard Polyiso Insulation or LRF-XF Min.0.25-inch SECUROCK LRF-XF Smooth/torch- /hot asphalt,GAF 2-Part(spatter),LRF- _180.0 concrete EnergyGuard RH Gypsum-Fiber Roof Board applied XF(spatter)or OB500(spatter)or LRF- O,4-inch o.c. Self-Adhering Base Ply: EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, Liberty SBS Self- C-273. Structural EnergyGuard RH,EnergyGuard RM or LRF-M or Min.um-Finch Roof Board LRF-M or Adhering Cap Sheet/ EverGuard TPO Fleece-Back Membrane _60.0 concrete EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 self-adhered /LRF-O,12-inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 100 of 156 NNEMO I etc. TABLE 313:STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED BASE OPTIONSREFER To NOTE 16 FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP (Notes 6,7,8) No. (Note 1) Type Attach Type Attach(Notes 6,7,8) Base Ply Cap Ply (psf) EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, Liberty SBS Self- EverGuard TPO Fleece-Back Membrane Structural Min.0.25-inch SECUROCK /hot asphalt,GAF 2-Part(spatter),LRF- C-274. EnergyGuard RH,EnergyGuard RM or LRF-M or LRF-M or Adhering Cap Sheet/ -180.0 concrete EnergyGuard RN OB500 Gypsum-Fiber Roof Board 06500 self-adhered XF(spatter)or OB500(spatter)or LRF- O,4-inch o.c. C-275. Structural EnergyGuard Polyiso Insulation or LRF-XF Min.0.25-inch SECUROCK Liberty SBS Self- LRF-XF Adhering Cap Sheet/ EverGuard TPO Fleece-Back Membrane _60.0 concrete EnergyGuard RH Gypsum-Fiber Roof Board self-adhered /LRF-O,12-inch o.c. Liberty SBS Self- EverGuard TPO Fleece-Back Membrane Structural EnergyGuard Polyiso Insulation or Min.0.25-inch SECUROCK /hot asphalt,GAF 2-Part(spatter),LRF- C-276. concrete EnergyGuard RH LRF-XF Gypsum-Fiber Roof Board LRF-XF Adhering Cap Sheet/ XF(spatter)or OB500(spatter)or LRF- -180.0 self-adhered O,4-inch o.c. CONCRETETABLE 3c:STRUCTURAL rECKS-NEW CONSTRUCTION OR REROOF SYSTEM TYPE F: • r BONDED System No. Deck(Note 1) Roof Cover(Note 15) MOP(psf) C-277. Min.2,500 psi structural concrete EverGuard TPO Fleece-Back Membrane/LRF-M or LRF-0,12-inch o.c. -60.0 C-278. Min.2,500 psi structural concrete EverGuard TPO Fleece-Back Membrane/WB181 -300.0 C-279. Min.3,000 psi structural concrete primed with MatrixT"307 Premium Asphalt Primer. EverGuard TPO Fleece-Back Membrane/Hot asphalt -390.0 C-280. Min.2,500 psi structural concrete EverGuard TPO Fleece-Back Membrane/OB500(spatter) -435.0 C-281. Min.2,500 psi structural concrete EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter) -497.5 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMD ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 101 of 156 NNEMO etc. BILE 4A:LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) O DECK,BONDED INSULATION,BONDED ROOF COVER Base Insulation Layer Coverboard System Deck Lightweight Concrete MDP No. (Note 1) (Note 14) Type Attach Type Attach Roof Cover(Note 15) (psf) (Notes 6,7,8) (Notes 6,7,S) CELCORE(FL2O37): EverGuard Freedom TPO: Structural Min.200 psi,min.2-inch thick Celcore Cellular Min.1.5-inch EnergyGuard RA, Min.0.25-inch SECUROCK EverGuard Freedom LWC-1. concrete Concrete EnergyGuard RH or EnergyGuard RN GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO/self adhered 222.5 EverGuard TPO/EverGuard TPO#1121 Bonding Adhesive or EVERUGARD TPO 3 SQUARE LOW VOC BONDING ADHESIVE: Min.0.25-inch DensDeck, LWC-2. Structural Min.200 psi,min.2-inch thick Celcore Cellular Min.1.5-inch thick,min.1.25 pcf density GAF 2-Part DensDeck Prime or GAF 2-Part EverGuard TPO/ 87 5 concrete Concrete Insulfoam EPS or STYROFOAM Brand XPS SECUROCK Gypsum Fiber #1121,TPO 3-Square Roof Board (Optional)Min.1.5-inch EnergyGuard EnergyGuard RH or EnergyGuard RN Structural Min.200 psi,min.2-inch thick Celcore Cellular RA, Min.0.25-inch DensDeck EverGuard TPO/ LWC-3. concrete Concrete or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part or DensDeck Prime GAF 2-Part #1121,TPO 3-Square -130.0 density Insulfoam EPS or STYROFOAM Brand XPS LWC-4. Structural Min.200 psi,min.2-inch thick Celcore Cellular Min.1.5-inch EnergyGuard Polyiso GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/ 222 5 concrete Concrete Insulation,EnergyGuard Ultra of base insulation #1121,TPO 3-Square (Optional)Min.1.5-inch EnergyGuard Structural Min.200 psi,min.2-inch thick Celcore Cellular RA,EnergyGuard RH or EnergyGuard RN Min.0.25-inch SECUROCK EverGuard TPO/ LWC-5. concrete Concrete or Min.1.5-inch thick,min.2.0 pcf GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part #1121,TPO 3-Square 222.5 density Insulfoam EPS or STYROFOAM Brand XPS EverGuard TPO/EverGuard WB181 Bonding Adhesive: LWC-6. Structural Min.200 psi,min.2-inch thick Celcore Cellular Min.1.5-inch thick,min.1.25 pcf density GAF 2-Part Min.0.25-inch DensDeck GAF 2-Part EverGuard TPO/ 87 5 concrete Concrete Insulfoam EPS or STYROFOAM Brand XPS Prime WB181 (Optional)Min.1.5-inch EnergyGuard LWC-7. Structural Min.200 psi,min.2-inch thick Celcore Cellular RA,EnergyGuard RH or EnergyGuard RNor Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck GAF 2-Part EverGuard TPO/ -130.0 concrete Concrete density Insulfoam EPS or STYROFOAM Prime W8181 Brand XPS LWC-8. Structural Min.200 psi,min.2-inch thick Celcore Cellular Min.1.5-inch EnergyGuard Polyiso GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/ 222 5 concrete Concrete Insulation,EnergyGuard Ultra of base insulation WB181 EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch DensDeck EverGuard TPO TPO =LWC_�� concretre l Min.200 psi,min.2-inch thick Celcore Cellular RA,EnergyGuard RH or EnergyGuard RN, Concrete min.1.5-inch thick,min.1.25 pcf density GAF 2-Part Prime or SECUROCK GAF 2-Part 6-Square,TPO 3- -45.0 Insulfoam EPS or STYROFOAM Brand XPS Gypsum-Fiber Roof Board Square NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 102 of 156 NNEMO I etc. TABLE 4A:LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) I SYSTEM TYPE A-1:LWC O DECK,BONDED INSULATION,BONDED System Deck Lightweight Concrete Base Insulation Layer Coverboard MDP No. (Note 1) (Note 14) Type Attach Type Attach Roof Cover(Note 15) (psf) (Notes 6,7,8) (Notes 6,7,8) Structural Min.200 psi,min.2-inch thick Celcore Cellular Min.1.5-inch EnergyGuard Polyiso GAF 2-Part (Optional)Additional layer EverGuard TPO LWC-10. concrete Concrete Insulation,EnergyGuard Ultra of base insulation GAF 2-Part 6-Square,TPPOO 3-- -222.5 Square ELASTIZELL(FL4994): EverGuard Freedom TPO: LWC-11. Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch EnergyGuard RA, GAF 2-Part Min.0.25-inch SECUROCK GAF 2-Part EverGuard Freedom _180.0 concrete LWC EnergyGuard RH or EnergyGuard RN Gypsum-Fiber Roof Board TPO/self adhered LWC-12. Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch EnergyGuard Polyiso OB500 (Optional)Additional layer OB500 EverGuard Freedom -142.5 concrete LWC Insulation,EnergyGuard Ultra of base insulation TPO/self adhered LWC-13. Structural Min.200 psi,min.2-inch thick Elastizell Range II (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch SECUROCK EverGuard Freedom concrete LWC RA,EnergyGuard RH or EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 TPO/self adhered -225.0 EverGuard TPO/EverGuard TPO#1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min.0.25-inch DensDeck, LWC-14. Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch thick,min.1.25 pcf density GAF 2-Part DensDeck Prime or GAF 2-Part EverGuard TPO/ 87 5 concrete LWC Insulfoam EPS or STYROFOAM Brand XPS SECUROCK Gypsum-Fiber #1121,TPO 3-Square Roof Board (Optional)Min.1.5-inch EnergyGuard LWC-15. Structural Min.200 psi,min.2-inch thick Elastizell Range II RA,EnergyGuard RH or EnergyGuard RNor Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min. inch DensDeck GAF 2-Part EverGuard / -130.0 concrete LWC density Insulfoam EPS or STYROFOAM or DensDeck 3-Sck Prime #1121,TPO 3-Square Brand XPS (Optional)Min.1.5-inch EnergyGuard LWC-16. Structural Min.200 psi,min.2-inch thick Elastizell Range II RA,EnergyGuard RH or EnergyGuard RN Min.0.25-inch SECUROCK EverGuard TPO/ concrete LWC or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part #1121,TPO 3-Square -180.0 density Insulfoam EPS or STYROFOAM Brand XPS Min.0.25-inch DensDeck, LWC-17. Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.2-inch,min.2.0 pcf,Insulfoam EPS OB500 DensDeck Prime or OB500 EverGuard TPO/ -120.0 concrete LWC SECUROCK Gypsum-Fiber #1121,TPO 3-Square Roof Board LWC-18. Structural Min.200 psi,min.2-inch thick Elastizell Range II (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch DensDeck EverGuard TPO/ concrete LWC RA,EnergyGuard RH or EnergyGuard RN OB500 or DensDeck Prime OB500 #1121,TPO 3-Square -130.0 LWC-19. Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch EnergyGuard Polyiso OB500 (Optional)Additional layer OB500 EverGuard TPO/ -180.0 concrete LWC Insulation,EnergyGuard Ultra of base insulation #1121,TPO 3-Square Structural Min.200 psi,min.2-inch thick Elastizell Range II (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch SECUROCK EverGuard TPO/ LWC-20. concrete LWC RA,EnergyGuard RH or EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 #1121,TPO 3-Square -180.0 EverGuard TPO/EverGuard WB181 Bonding Adhesive: lm NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 103 of 156 NNEMO I etc. TABLE 4A:LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) I SYSTEM TYPE A-1:LWC O DECK,BONDED INSULATION,BONDED System Deck Lightweight Concrete Base Insulation Layer Coverboard MDP No. (Note 1) (Note 14) Type Attach Type Attach Roof Cover(Note 15) (psf) (Notes 6,7,8) (Notes 6,7,8) LWC-21. Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch thick,min.1.25 pcf density GAF 2-Part Min.0.25-inch DensDeck GAF 2-Part EverGuard TPO/ 87 5 concrete LWC Insulfoam EPS or STYROFOAM Brand XPS Prime WB181 (Optional)Min.1.5-inch EnergyGuard Structural Min.200 psi,min.2-inch thick Elastizell Range II RA,EnergyGuard RH or EnergyGuard RN Min.0.25-inch DensDeck EverGuard TPO/ LWC-22. concrete LWC or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Prime GAF 2-Part WB181 -130.0 density Insulfoam EPS or STYROFOAM Brand XPS LWC-23. Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch EnergyGuard Polyiso GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/ -180.0 concrete LWC Insulation,EnergyGuard Ultra of base insulation WB181 Structural Min.200 psi,min.2-inch thick Elastizell Range II Min Min.0.25-inch DensDeck OB500 EverGuard TPO -120.0 / LWC-24. concrete LWC .2-inch,min.2.0 pcf,Insulfoam EPS OB500 Prime WB181 LWC-25. Structural Min.200 psi,min.2-inch thick Elastizell Range II (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch DensDeck EverGuard TPO/ concrete LWC RA,EnergyGuard RH or EnergyGuard RN OB500 Prime OB500 WB181 -130.0 Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch EnergyGuard Polyiso (Optional)Additional layer EverGuard TPO/ LWC-26. concrete LWC Insulation,EnergyGuard Ultra OB500 of base insulation OB500 W8181 -180.0 EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch DensDeck EverGuard TPO TPO Structural Min.200 psi,min.2-inch thick Elastizell Range II RA,EnergyGuard RH or EnergyGuard RN, LWC-27. concrete LWC min.1.5-inch thick,min.1.25 pcf density GAF 2-Part Prime or SECUROCK GAF 2-Part Squarere,TPO 3- -45.0 Insulfoam EPS or STYROFOAM Brand XPS Gypsum-Fiber Roof Board Square Structural Min.200 psi,min.2-inch thick Elastizell Range II Min.1.5-inch EnergyGuard Polyiso (Optional)Additional layer EverGuard PO -TPO LWC-28. concrete LWC Insulation,EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part Squarere,TPO 3- -180.0 Square Structural Min.200 psi,min.2-inch thick Elastizell Range II (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch DensDeck EverGuard TPO/TPO LWC-29. RA,EnergyGuard RH or EnergyGuard RN, OB500 Prime or SECUROCK OB500 6-Square,TPO 3- -45.0 concrete LWC min.2-inch,min.2.0 pcf,Insulfoam EPS Gypsum-Fiber Roof Board Square MEARLCRETE(FL13492): EverGuard Freedom TPO: LWC-30. Structural Min.200 psi,min.2-inch thick Mearlcrete Min.1.5-inch EnergyGuard RA, GAF 2-Part Min.0.25-inch SECUROCK GAF 2-Part EverGuard Freedom -240.0 concrete EnergyGuard RH or EnergyGuard RN Gypsum-Fiber Roof Board TPO/self adhered LWC-31. Structural Min.250 psi,min.2-inch Mearlcrete Min.0.25-inch SECUROCK Gypsum-Fiber OB500 None N/A EverGuard Freedom 75 0 concrete Roof Board TPO/self adhered EverGuard TPO/EverGuard TPO#1121 Bonding Adhesive or EVERUGARD TPO 3 SQUARE LOW VOC BONDING ADHESIVE: MAI Min.0.25-inch DensDeck, LWC-32. Structural Min.200 psi,min.2-inch thick Mearlcrete Min.1.5-inch thick,min.1.25 pcf density GAF 2-Part DensDeck Prime or GAF 2-Part EverGuard TPO/ 87 5 concrete Insulfoam EPS or STYROFOAM Brand XPS SECUROCK Gypsum-Fiber #1121,TPO 3-Square Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FLS293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMD ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 104 of 156 NNEMO I etc. BILE 4A:LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) O DECK,BONDED INSULATION,BONDED 7No. 7(Note Lightweight Concrete Base Insulation Layer Coverboard MDP (Note 14) Type Attach Type Attach Roof Cover(Note 15) (psfl (Notes 6,7,8) (Notes 6,7,8) (Optional)Min.1.5-inch EnergyGuard RA,EnergyGuard RH or EnergyGuard RN LWC-33. Structural Min.200 psi,min.2-inch thick Mearlcrete or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck GAF 2-Part EverGuard TPO/ -130.0 concrete density Insulfoam EPS or STYROFOAM or DensDeck Prime #1121,TPO 3-Square Brand XPS (Optional)Min.1.5-inch EnergyGuard Structural RA,EnergyGuard RH or EnergyGuard RN Min.0.25-inch SECUROCK EverGuard TPO/ LWC-34. concrete Min.200 psi,min.2-inch thick Mearlcrete or Min.1.5-inch thick,min.2.0 pcf GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part #1121,TPO 3-Square -240.0 density Insulfoam EPS or STYROFOAM Brand XPS EverGuard TPO/EverGuard WB181 Bonding Adhesive: LWC-35. Structural Min.200 psi,min.2-inch thick Mearlcrete Min.1.5-inch thick,min.1.25 pcf density GAF 2-Part Min.0.25-inch DensDeck GAF 2-Part EverGuard TPO/ 87 5 concrete Insulfoam EPS or STYROFOAM Brand XPS Prime WB181 (Optional)Min.1.5-inch EnergyGuard RA,EnergyGuard RH or EnergyGuard RN LWC-36. Structural Min.200 psi,min.2-inch thick Mearlcrete or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck GAF 2-Part EverGuard TPO/ -130.0 concrete density Insulfoam EPS or 5TYROFOAM Prime WB181 Brand XPS LWC-37. Structural Min.200 psi,min.2-inch thick Mearlcrete Min.1.5-inch EnergyGuard Polyiso GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/ -240.0 concrete Insulation,EnergyGuard Ultra I of base insulation WB181 EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: (Optional)Min.1.5-inch EnergyGuard Min.0.25-inch DensDeck EverGuard TPO TPO Structural RA,EnergyGuard RH or EnergyGuard RN, LWC-38. concrete Min.200 psi,min.2-inch thick Mearlcrete min.1.5-inch thick,min.1.25 pcf density GAF 2-Part Prime or SECUROCK GAF 2-Part 6-Square,TPO 3- -45.0 Insulfoam EPS or STYROFOAM Brand XPS Gypsum-Fiber Roof Board Square Structural Min.1.5-inch EnergyGuard Polyiso (Optional)Additional layer EverGuard TPO/TPO LWC-39. concrete Min.200 psi,min.2-inch thick Mearlcrete Insulation,EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part 6-Square,TPO 3- -240.0 Square PRE-EXISTENT CELLULAR LWC(NOTE 14): EverGuard TPO/EverGuard TPO#1121 Bonding Adhesive: LWC-40. Structural Min.290 psi,min.3-inch thick pre-existent cellular Min.1-inch EnergyGuard Polyiso OB500 (Optional)Additional OB500 EverGuard TPO/ 47 5 concrete lightweight insulating concrete Insulation or EnergyGuard RH layer(s)base insulation #1121 Min.1-inch EnergyGuard Polyiso Structural Min.290 psi,min.3-inch thick pre-existent cellular Insulation,EnergyGuard Ultra Polyiso Min.0.25-inch DensDeck EverGuard TPO/ LWC-41. concrete lightweight insulating concrete Insulation,EnergyGuard RA, OB500 Prime or SECUROCK OB500 #1121 -67.5 EnergyGuard RH,EnergyGuard RN or Gypsum-Fiber Roof Board EnergyGuard RM EverGuard TPO/EverGuard WB181 Bonding Adhesive: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 MEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 105 of 156 NNEMO etc. TABLE 4A:LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) O DECK,BONDED INSULATION,BONDED System Deck Lightweight Concrete Base Insulation Layer Coverboard MDP No. (Note 1) (Note 14) Type Attach Type Attach Roof Cover(Note 15) (psf) (Notes 6,7,8) (Notes 6,7,8) LWC-42. Structural Min.290 psi,min.3-inch thick pre-existent cellular Min.1-inch EnergyGuard Polyiso OB500 (Optional)Additional OB500 EverGuard TPO/ 47 5 concrete lightweight insulating concrete Insulation layer(s)base insulation WB181 Min.1-inch EnergyGuard Polyiso Min.0.5-inch EnergyGuard Structural Min.290 psi,min.3-inch thick pre-existent cellular Insulation,EnergyGuard Ultra Polyiso HD Polyiso Insulation or EverGuard TPO/ LWC-43. concrete lightweight insulating concrete Insulation,EnergyGuard RA, OB500 EnergyGuard HD Plus OB500 WB181 -47.5 EnergyGuard RH,EnergyGuard RN or EnergyGuard RM Polyiso Insulation EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive: Min.1-inch EnergyGuard Polyiso LWC-44. Structural Min. ei psi,min.3-inch thick pre-existent cellular Insulation,EnergyGuard RA or OB500 (Optional)Additional OB500 EverGuard TPO TPOr47.5concrete lightweight insulating concrete EnergyGuard RHlayer(s)base insulation 6-SquareMin.1-inch EnergyGuard Polyiso Structural Min.290 psi,min.3-inch thick pre-existent cellular Insulation,EnergyGuard Ultra Polyiso Min.0.25-inch DensDeck EverGuard TPO/TPO LWC-45. Insulation,EnergyGuard RA, OB500 Prime or SECUROCK OB500 concrete lightweight insulating concrete EnergyGuard RH,EnergyGuard RN or Gypsum-Fiber Roof Board 6-Square EnergyGuard RM EverGuard TPO/EverGuard TPO Quick Spray Adhesive: Min.400 psi,min.2-inch thick pre-existent cellular lightweight insulating concrete;mote:To qualify the Min.0.5-inch EnergyGuard HD Polyiso LWC-46. Structural LWIC under this assembly,a Drill-TecTM Base Sheet EverGuard TPO TPO concrete Fastener(1.7 in.)or Drill-Tec'"Base Sheet Fastener E(1.7 Insulation,EnergyGuard HD Plus Polyiso LRF-XF None N/A QSA -230.0 in.)shall achieve MCRF of 117 lbfor greater when tested Insulation per TA5105. Min.400 psi,min.2-inch thick pre-existent cellular lightweight insulating concrete;Mote:To qualify the Min.0.5-inch EnergyGuard HD Polyiso Structural LWIC under this assembly,a Drill-TecTM Base Sheet EverGuard TPO TPO LWC-47. Insulation,EnergyGuard HD Plus Polyiso OB500 None N/A -140.0 Concrete Fastener(1.7 in.)or Drill-Tec'"Base Sheet Fastener E(1.7 Insulation ClSA in.)shall achieve MCRF of 117lbf or greater when tested per TA5105. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 106 of 156 NNEMO etc. TABLE 4B:LIGHTWEIGHT CONCRETE OVER STEEL DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2:LWC DECK,MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Lightweight Anchor Sheet Insulation Roof Cover(Note 15) System Deck MDP Concrete Fasteners Attach No. (Note 1) (Note 14) Type (Note 11) Attach Base Top (Notes 6,7,8) Base Ply Cap Ply (psf) CELCORE(FL2037): GAFG LAS#75 Base Sheet, Drill-Tec Base 9-inch o.c.at the 2- Min.22 Minimum 300 psi, Tri-Ply#75 Base Sheet, inch side lap and 9- Min.1.5-inch Min.0.25-inch EverGuard ga.,type minimum 2-inch GAFGLAS#80 Ultima Base Sheet Fastener inch o.c.at two, EnergyGuard RA, SECUROCK Freedom LWC-48. BV,Grade thick Celcore Sheet or GAFGLAS (1.7 in.)or Drill- equally spaced, EnergyGuard RH, Gypsum-Fiber OB500 None TPO/Self- 45.0 33 steel Cellular Concrete Stratavent Nailable Tec Base Sheet staggered rows in the EnergyGuard RN Roof Board adhered Venting Base Sheet Fastener E(1.7 in.) center of the sheet Min.0.25-inch DensDeck GAFGLAS#75 Base Sheet, 9-inch o.c.at the 2- Prime or EverGuard Min.22 Minimum 300 psi, Tri-Ply#75 Base Sheet, Drill-Tec Base SECUROCK inch side lap and 9- Min.1.5-inch TPO Sheet Fastener Gypsum-Fiber / ga.,type minimum 2-inch GAFGLAS#80 Ultima Base inch o.c.at two, EnergyGuard RA, #1121,TPO BV,Grade thick Celcore Sheet or GAFGLAS LWC-49. (1.7 in.)or Drill- Roof Board or 08 6-Square,500 None -45.0 equally spaced, EnergyGuard RH, Tec Base Sheet min.tod inch 33 steel Cellular Concrete Stratavent Nailable staggered rows in the EnergyGuard RN StruTPO 3- Venting Base Sheet Fastener E(1.7 in.) center of the sheet High Density n Square High Density Fiberboard Roof Insulation GAFG LAS#75 Base Sheet, Drill-Tec Base 9-inch o.c.at the 2- Min.0.25-inch Min.22 Minimum 300 psi, Tri-Ply#75 Base Sheet, inch side lap and 9- Min.1.5-inch DensDeck Sheet Fastener EverGuard in.) TPOLWC-50. ga.,type minimum 2-inch GAFGLAS#80 Ultima Base inch o.c.at two, EnergyGuard RA, Prime or OB500 None BV,Grade thick Celcore Sheet or GAFGLAS Tec Base Sheet or Drill- equally spaced, EnergyGuard RH, SECUROCK WB/ -45.0 Tec 181 33 steel Cellular Concrete Stratavent Nailable staggered rows in the EnergyGuard RN Gypsum-Fiber Venting Base Sheet Fastener E(1.7 in.) center of the sheet Roof Board GAFGLAS#75 Base Sheet, Drill-Tec Base 9-inch o.c.at the 2- Min.0.25-inch EverGuard Min.22 Minimum 300 psi, Tri-Ply#75 Base Sheet, inch side lap and 9- Min.1.5-inch DensDeck Sheet Fastener TPO Fleece- LWC-51. ga.,type minimum 2-inch GAFGLAS#80 Ultima Base inch o.c.at two, EnergyGuard RA, Prime or (1.7 in.) S heet Drill- 0B500 None Back -45.0 Tec Base S BV,Grade thick Celcore Sheet or GAFGLAS equally spaced, EnergyGuard RH, SECUROCK 33 steel Cellular Concrete Stratavent Nailable staggered rows in the EnergyGuard RN Gypsum-Fiber Membrane/ 7 in Venting Base Sheet Fastener E(1. .) center of the sheet Roof Board WB181 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 107 of 156 NNEMO etc. TABLE 4c:LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2:LWC DECK,MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Lightweight Anchor Sheet Insulation Roof Cover(Note 15) System Deck MDP Concrete Fasteners Attach No. (Note 1) (Note 14) Type (Note 11) Attach Base Top (Notes 6,7,S) Base Ply Cap Ply (psf) CELCORE(FL2037): GAFG LAS#75 Base Sheet, Drill-Tec Base 9-inch o.c.at the 2- Minimum 300 psi, Tri-Ply#75 Base Sheet, inch side lap and 9- Min.1.5-inch Min.0.25-inch EverGuard Structural minimum 2-inch GAFGLAS#80 Ultima Base Sheet Fastener inch o.c.at two, EnergyGuard RA, SECUROCK Freedom LWC-52. concrete thick Celcore Sheet or GAFGLAS (1.7 in.)or Drill- equally spaced, EnergyGuard RH, Gypsum-Fiber OB500 None TPO/Self- 45.0 Cellular Concrete Stratavent Nailable Tec Base Sheet staggered rows in the EnergyGuard RN Roof Board adhered Venting Base Sheet Fastener E(1.7 in.) center of the sheet Min.0.25-inch DensDeck GAFGLAS#75 Base Sheet, 9-inch o.c.at the 2- Prime or EverGuard Minimum 300 psi, Tri-Ply#75 Base Sheet, Drill-Tec Base inch side lap and 9- Min.1.5-inch SECUROCK TPO/ Structural minimum 2-inch GAFGLAS#80 Ultima Base Sheet Fastener inch o.c.at two, EnergyGuard RA, Gypsum-Fiber #1121,TPO LWC-53. concrete thick Celcore Sheet or GAFGLAS (1.7 in.)or Drill- equally spaced, EnergyGuard RH, Roof Board or OB500 None 6-Square, -45.0 Tec Base Sheet min.0.5-inch Cellular Concrete Stratavent Nailable staggered rows in the EnergyGuard RN TPO 3- StruVenting Base Sheet Fastener E(1.7 in.) center of the sheet High Density n Square High Density Fiberboard Roof Insulation GAFG LAS#75 Base Sheet, 9-inch o.c.at the 2- Min.0.25-inch Minimum 300 psi, Tri-Ply#75 Base Sheet, Drill-Tec Base inch side lap and 9- Min.1.5-inch DensDeck Sheet Fastener EverGuard in.) Structural minimum 2-inch GAFGLAS#80 Ultima Base inch o.c.at two, EnergyGuard RA, Prime or LWC-54. concrete thick Celcore Sheet or GAFGLAS Tec Base Sheet or Drill- equally spaced, EnergyGuard RH, SECUROCK OB500 None WBTPO/ -45.0 Tec 181 Cellular Concrete Stratavent Nailable staggered rows in the EnergyGuard RN Gypsum-Fiber Venting Base Sheet Fastener E(1.7 in.) center of the sheet Roof Board GAFGLAS#75 Base Sheet, Drill-Tec Base 9-inch o.c.at the 2- Min.0.25-inch EverGuard Minimum 300 psi, Tri-Ply#75 Base Sheet, inch side lap and 9- Min.1.5-inch DensDeck Sheet Fastener TPO Fleece- Structural minimum 2-inch GAFGLAS#80 Ultima Base inch o.c.at two, EnergyGuard RA, Prime or LWC-55. Tec in.)Base Sheet or Drill- 0B500 None Back -45.0 concrete thick Celcore Sheet or GAFGLAS equally spaced, EnergyGuard RH, SECUROCK Cellular Concrete Stratavent Nailable Tec staggered rows in the EnergyGuard RN Gypsum-Fiber Membrane/ Venting Base Sheet Fastener E(1.7 in.) center of the sheet Roof Board WB181 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 108 of 156 NNEMO I etc. TABLE 41D:LIGHTWEIGHT CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEMTYPEE-2:LWCTO DECK,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER 7Base Sheet Roof Cover(Note 15) MOP System Deck(Note 1) Lightweight Concrete(Note 14) Fasteners No. Type Attach Base Cap (psf) (Note 11) MEARLCRETE(FL13492): EverGuard Freedom TPO: Min.22 ga., type B,Grade 33 vented steel 7.5-inch o.c.in the 4-inch lap Drill-Tec Locking and 12-inch o.c.in three, at max.6 ft Min.300 psi,min.2-inch thick GAF StormSafe Anchor EverGuard LWC-56. spans or min. Mearlcrete Sheet Impact Nail,min.1.8- equally spaced,staggered None Freedom TPO -52.5 2,500 psi inch rows in the center of the structural sheet concrete PRE-EXISTENT CELLULAR LWC: EverGuard Freedom TPO: Min.22 ga., type B,Grade 12-inch o.c.at the 4-inch lap 33 vented steel Drill-Tec#12 screws Min.250-300 psi,min.2-inch thick and 12-inch o.c.in three, at max.6 ft GAF StormSafe Anchor and Drill-Tec EverGuard LWC-57. spans or min. pre-existent cellular lightweight Sheet AccuTrac Flat Plates equally spaced,staggered None Freedom TPO -45.0 2,500 psi concrete (engage steel deck) rows in the center of the structural sheet concrete Hybrid Systems: Min.22 ga., Min.340 psi,min.2-inch thick pre- GAFG LAS#75 Base Drill-Tec Base Sheet (Optional)One or two plies type B,Grade existent cellular lightweight Sheet,Tri-Ply#75 Base Ruberoid 20 Smooth,Ruberoid 40 vented steel concrete.Note:To qualify the LWIC Sheet,GAFGLAS#80 Fastener as in.)et 7-inch o.c.at min.4-inch laps Mop Smooth,Ruberoid Mop EverGuard Drs a ec Base Sheet TPOBack Fleece- at max.6 ft under this assembly,the selected Ultima Base Sheet, and 7-inch o.c.in two, Smooth 1.5 or Ruberoid Mop Plus LWC-58. spans or min. fastener shall achieve an average GAFGLAS Stratavent Fastener E(1.7 in.), equally spaced,staggered Smooth in hot asphalt or one or Back -52.5 2,500 psi withdrawal of 60 lbf or greater Nailable Venting Base Drill-Tec Locking center rows two plies Ruberoid HW 25 Smooth Membrane in structural when tested per TAS105 or Sheet,Ruberoid 20 Impact Nail or or Ruberoid HW Smooth,torch- hot apshalt concrete ANSI/SPRI FX-1 Smooth Trufast FM-290 applied EverGuard Min.22 ga., Min.340 psi,min.2-inch thick pre- GAFGLAS#75 Base Drill-Tec Base Sheet One or two plies Ruberoid 20 TPO Fleece- type B,Grade existent cellular lightweight Sheet,Tri-Ply#75 Base Smooth,Ruberoid Mop Smooth, Back 40 vented steel concrete.Note:To qualify the LWIC Sheet,GAFGLAS#80 Fastener as in.)et 7-inch o.c.at min.4-inch laps Ruberoid Mop Smooth 1.5 or Membrane in Drste ec Base Sheet at max.6 ft under this assembly,the selected Ultima Base Sheet, and 7-inch o.c.in two, Ruberoid Mop Plus Smooth in hot GAF 2-Part LWC-59. sans or min. fastener shall achieve an average GAFGLAS Stratavent Fastener E(1.7 in.), equally spaced,staggered asphalt or one or two lies (spatter), -52.5 p g Drill-Tec Locking q y p gg p p LR 2,500 psi withdrawal of 6016f or greater Nailable Venting Base center rows Ruberoid HW 25 Smooth or LRF-XF structural when tested per TAS105 or Sheet,Ruberoid 20 Impact Nail or Ruberoid HW Smooth,torch- (spatter)or concrete ANSI/SPRI FX-1 Smooth Trufast FM-290 applied OB500 (spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 109 of 156 NNEMO etc. TABLE 41):LIGHTWEIGHT CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEIVITYPEE-2:LWCTO DECK,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER Base Sheet Roof Cover(Note 15) Sys MDP toem Deck(Note 1) Lightweight Concrete(Note 14) Type Fasteners Attach Base Cap (ps) (Note 11) EverGuard Drill-Tec XHD Min.22 ga., Fastener with Drill- Fasteners located 3.75-inch TPO Fleece- from edge of sheet,and Back type B,Grade Tec 2-3/8 in.Barbed s (Optional)Ruberoid HW 25 Ruberoid Mop Smooth, paced 12-inch o.c.within Membrane in 50 steel at Min.180 psi,min.3-inch thick pre- XHD Plate or Drill- Ruberoid Mop Smooth the min.6.25-inch wide laps. GAF 2-Part 1.5 or Ruberoid Mop Laps sealed with min.4-inch LWC-60. max.6 ft spans existent cellular lightweight Tec Eyehook Smooth or Ruberoid HW (spatter), Smooth, -60.0 or min.2,500 concrete. Plus Smooth AccuSeam Plate, wide heat-weld, torch-applied LRF-XF psi structural fastened through concrete LWC to engage steel encapsulating the fastener (spatter)or deck row OB500 (spatter) Re-Roof Only:Min.210 psi,min.2- Min.22ga., inch thick pre-existent cellular EverGuard Drill-Tec Base Sheet type BV,Grade lightweight insulating concrete; TPO Fleece- 40 steel at Note:To qualify the pre-existent Fastener(1.7 in.)or 7-inch o.c.at min.4-inch laps Ruberoid HW 25 Smooth or Back LWC-61. max.6 ft spans LWIC under this assembly,the Ruberoid 20 Smooth Drill-Tec Base Sheet and 7-inch o.c.in two,Fastener E(1.7 in.), equally spaced,staggered Ruberoid HW Smooth,torch Membrane in -82.5 or min.2,500 selected fastener shall achieve an Fast Tec Locking center rows applied GAF 2-Part psi structural average withdrawal of 95lbf or Drill-Impact Nail (spatter)or concrete greater when tested per AN51/5PRI hot asphalt FX-1 or TAS105. Re-Roof Only:Min.210 psi,min.2- Min.22ga., inch thick pre-existent cellular EverGuard type BV,Grade lightweight insulating concrete; TPO Fleece- GAFGLAS ft80 Ultima Drill-Tec Base Sheet 7-inch o.c.at min.4-inch laps 40 steel at Note:To qualify the pre-existent Ruberoid HW 25 Smooth or Back Base Sheet or GAFGLAS Fastener(1.7 in.), and 7-inch o.c.in two, LWC-62. max.6 ft spans L WIC under this assembly,the Stratavent Nailable Drill-Tec Locking equally spaced,staggered Ruberoid HW Smooth,torch Membrane in -82.5 or min.2,500 selected fastener shall achieve an Venting Base Sheet Impact Nail center rows applied GAF 2-Part psi structural average withdrawal cf 95lbf or (spatter)or concrete greater when tested per AN51/5PRI hot asphalt FX-1 or TAS105. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 110 of 156 NNEMO I etc. TABLE 4E:LIGHTWEIGHT CONCRETE OVER STEEL DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:LVIC .DECK,BONDED ROOF COVER Lightweight Concrete(Note 14) Roof Cover(Note 15) MDP 71: Deck(Note 1) Min.Compressive Min.Type Strength(psi) Thickness(in) Type Attach (psf) CONCRECEL(FL5584 AND FL10500): Min.22 ga.,type BV,Grade 33 EverGuard TPO GAF 2-Part(spatter)or LAIC-63. steel at max.6 ft spans Concrecel 290 2 Fleece-Back OB500(spatter) -52.5 Membrane EusTIZELL(FL4994): Min.22 ga.,type BV,Grade 33 EverGuard TPO GAF 2-Part(spatter)or LWC-64. steel at max.6 ft spans Elastizell 290 2 Fleece-Back OB500(spatter) -52.5 Membrane EverGuard TPO LWC-65. Min.22 ga.,type BV,Grade 33 Elastizell 160 3 Fleece-Back GAF 2-Part(spatter)or -60.0 steel at max.6 ft spans Membrane OB500(spatter) MEARLCREfE(FL13492): EverGuard TPO LWC-66. Min.22 ga.,type BV,Grade 33 Mearlcrete 300 2 Fleece-Back EverGuard WB181 -52.5 steel at max.6 ft spans Membrane Bonding Adheisve Min.22 ga.,type BV,Grade 33 EverGuard TPO Mearlcrete 300 2 Fleece-Back Membrane LRF-M or LRF-O,4-inch -52.5 LWC-67. steel at max.6 ft spans O.C. Min.22 ga.,type BV,Grade 33 EverGuard TPO GAF 2-Part(spatter)or LWC-68. steel at max.6 ft spans Mearlcrete 300 2 Fleece-Back OB500(spatter) -52.5 Membrane Min.22 ga.,type BV,Grade 33 EverGuard TPO GAF 2-Part(spatter)or LWC-69. steel at max.6 ft spans Mearlcrete 290 2 Fleece-Back OB500(spatter) -52.5 Membrane PRE-EXISTENT CELLULAR LWC: Pre-existent cellular lightweight insulating concrete;Note:To qualify LWC-70. Min.22 ga.,type BV,Grade 33 the LWIC under this assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or 400 2 EverGuard TPO #1121,TPO QSA or TPO -52.5 Steel;6 ft spans Drill-Tec'Base Sheet Fastener E(1.7 in.)shall achieve MCRF of 1171bf or QSA LV50 greater when tested per TAS105. Pre-existent cellular lightweight insulating concrete;Note:To qualify EverGuard TPO Min.22 ga.,type BV,Grade 33 the LWIC under this assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or EverGuard W 8181 LWC-71. 180 2 Fleece-Back steel at max.6 ft spans Drill-Tec'Base Sheet Fastener E(1.7in.)shall achieve an average withdrawal Bonding Adhesive -52.5 of 971bf or greater when tested perANSI/SPRI FX-1 or TAS305. Membrane Pre-existent cellular lightweight insulating concrete;Note:To qualify EverGuard TPO Min.22 ga.,type BV,Grade 33 the LWIC under this assembly,o Drill-Tec' Base Sheet Fastener(1.7in.)or GAF 2-Part(Spatter)or LWC-72. 180 2 Fleece-Back steel at max.6 ft spans Drill-Tec-Base Sheet Fastener E(1.7in.)shallachieve an average withdrawal OB500(spatter) -52.5 of 971bf or greater when tested perANSI/SPRI FX-1 or TAS305. Membrane NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 111 of 156 NNEMO I etc. TABLE 4E:LIGHTWEIGHT CONCRETE OVER STEEL DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:LWC .DECK,BONDED ROOF Lightweight Concrete(Note 14) Roof Cover(Note 15) System Deck(Note 1) Min.Compressive Min. MDP No. Type Strength(psi) Thickness(in) Type Attach (psf) Pre-existent cellular lightweight insulating concrete;Note:To qualify EverGuard TPO Min.22 ga.,type BV,Grade 33 the LWIC under this assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or LWC-73. steel;6ft spans Drill-Tec-Base Sheet Fastener E(1.7 in.)shall achieve MCRFof1171bfor 400 2 Fleece-Back LRF-XF(spatter) -52.5 greater when testedper TAS105. Membrane CONCRETETABLE 4F:LIGHTWEIGHT OVER • SYSTEM TYPE F:LWC TO DECK,BONDED Deck Lightweight Concrete(Note 14) Roof Cover(Note 15) MDP Syst em No. (Note 1) Type Min.Compressive Min. Type Attach (psf) Strength(psi) Thickness(in) CELCORE(FL2037): Structural EverGuard TPO Fleece- LRF-M or LRF-0, LWC-74. concrete Celcore Cellular Concrete 200 2 Back Membrane ribbons 4-inch o.c. -300.0 Structural EverGuard TPO Fleece- GAF 2-Part LWC-75. concrete Celcore Cellular Concrete 200 2 Back Membrane (spatter)or OB500 -300.0 (spatter) CONCRECEL(FL5584 AND FL10500): LWC-76, Structural Concrecel 200 2 EverGuard TPO Fleece- EverGuard WB181 -225.0 concrete Back Membrane Bonding Adhesive Structural EverGuard TPO Fleece- GAF 2-Part LWC-77. concrete Concrecel 200 2 Back Membrane (spatter)or OB500 -225.0 (spatter) Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-78. concrete Concrecel 200 2 Back Membrane ribbons 4-inch o.c. -225.0 ELASTIZELL(FL4994): Structural EverGuard TPO Fleece- EverGuard WB181 LWC-79. concrete Elastizell 220 2 Back Membrane Bonding Adhesive -200.0 Structural EverGuard TPO Fleece- GAF 2-Part LWC-80. concrete Elastizell 220 2 Back Membrane (spatter)or OB500 -200.0 (spatter) Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-81. concrete Elastizell 200 2 Back Membrane ribbons 4-inch o.c. -210.0 SIPLAST INSULCEL(NOA 16-1024.02): LWC-82. Structural Insulcel 200 2 EverGuard TPO Fleece- LRF-M or LRF-O,4- 270 0 concrete Back Membrane inch o.c. Structural EverGuard TPO Fleece- GAF 2-Part LWC-83. concrete Insulcel 200 2 Back Membrane (spatter)or OB500 -270.0 (spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization N32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 112 of 156 NNEMO I etc. GHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:LWC .DECK,BONDED ROOF COVER Lightweight Concrete(Note 14) Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Min.Compressive Min. Type Attach (psf) Strength(psi) Thickness(in) MEARLCRETE(FL13492): Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-84. concrete Mearlcrete 730 2 Back Membrane ribbons 6-inch o.c. -45.0 LWC-85. Structural Mearlcrete 290 2 EverGuard TPO Fleece- EverGuard WB181 -205.0 concrete Back Membrane Bonding Adhesive Structural EverGuard TPO Fleece- GAF 2-Part LWC-86. concrete Mearlcrete 290 2 Back Membrane (spatter)or OB500 -205.0 (spatter) Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-87. Mearlcrete 200 2 -270.0 concrete Back Membrane ribbons 4-inch o.c. PRE-EXISTENT CELLULAR LWC: Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWICunderthis Structural EverGuard TPO ran Fleece- inch o.ribbons 4- LWC-88. concrete assembly,aDrill-TecTM Base Sheet Fastener(1.7in.)orDrill-TecTM Base Sheet Fastener E/1.7in.lshall 180 2 Back Membrane inch o.c. -92.5 achieve an average withdrawal of 971bf or greater when tested perANSI/SPRI FX-1 or TA5105. Structural Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWIC under this EverGuard TPO Fleece- EverGuard WB181 LWC-89. concrete assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or Drill-TecTM Base Sheet Fastener E(1.7in.)shall 180 2 Back Membrane Bonding Adhesive -102.5 achieve an average withdrawal of 9716f or greater when tested perAN51/SPRI FX-1 or TAS105. Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWICunderthis GAF 2-Part LWC-90. Structural assembly,aDrill-TecTM Base Sheet Fastener(1.7 in.l or Drill-TecTM Base Sheet FastenerE(1.7 in.l shall 180 2 EverGuard TPO Fleece- (spatter)or OB500 -102.5 concrete achieve an average withdrawal of971bfor greater when tested perAN51/SPRIFX-1orTAS105. Back Membrane (spatter) ) Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWICunderthis LWC-91. Structural assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or Drill-TecTM Base Sheet FastenerE(1.7in.)shall 180 2 EverGuard ran Fleece- inchLRF-o.c. 4- -112.5 concrete achieve an average withdrawal of 971bf or greater when tested perANSI/SPRI FX-1 or TAS105. Back Membrane inch o.t. Structural Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWICunderthis LWC-92. assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or Drill-TecTM Base Sheet FastenerE(1.71n.)shall 400 2 EverGuard TPO #1121 -127.5 concrete achieve MCRF of 11716f or greater when tested per TAS105. Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWIC under this Structural EverGuard Fleece- LWC-93. concrete assembly,aDrill-TecTM Base Sheet Fastener(1.7in.)or Drill-TecTM ease Sheet Fastener (1.7in.)shall 400 2 Back Membrane e LRF-XF(spatter) -130.0 achieve MCRF of 1171bf or greater when tested per TAS105. Structural Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWICunderthis LWC-94. assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or Drill-TecTM Base Sheet FastenerE(1.7in.)shall 400 2 EverGuard TPO TPO QSA -150.0 concrete achieve MCRF of 11716f or greater when tested per TAS105. Structural Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWICunderthis LWC-95. assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or Drill-TecTM Base Sheet Fastener E(1.71n.)shall 400 2 EverGuard TPO TPO QSA LV50 -154.0 concrete achieve MCRF of 11716f or greater when tested per TAS105. Structural Pre-existent cellular lightweight insulating concrete;Note:To qualify the LWICunderthis EverGuard TPO LWC-96. concrete assembly,a Drill-TecTM Base Sheet Fastener(1.7in.)or Drill-TecTM Base Sheet FastenerE(1.7in.Jshall 540 2 EverGuard TPO #1121 BA 487.5 achieve an average withdrawal of 17816f orgreater when tested perANSI/SPRI FX-1 or TAS105. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 113 of 156 NNEMO I etc. TABLE 4G:LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:TEMP ROOF/VAPOR BARRIER . . BONDED Lightweight Concrete(Note 14) Roof Cover(Note 15) System Deck primer Temp Roof/ Min, Min. MDP No. (Note 1) Vapor Barrier Type Compressive Thickness Type Attach (psf) Strength(psi) (in) PRE-EXISTENT CELLULAR LWC: Pre-existent cellular lightweight insulating concrete;Note:To qualify EverGuard TPO EverGuard Matrix 307 Ruberoid HW structural the LWIC under this assembly,a Drill-TecTM Base Sheet Fastener(1.7 in.)or LWC-97. Premium Smooth,torch- 180 2 Fleece-Back W8181 Bonding -102.5 concrete Drill-TecTM Base Sheet Fastener E(1.7in.)shall achieve an average withdrawal Asphalt Primer applied Membrane Adhesive of 9716f or greater when tested per AN51/SPRI FX-1 or TA5105. Matrix 307 Ruberoid HIMPre-existent cellular lightweight insulating concrete;Note:To qualify EverGuard TPO Structura ,a Drill-TecTM Base Sheet Fastener(1.7 in.)or LRF-M,ribbons the LWIC under this assembly LWC-98. Premium Smooth,torch- 180 2 Fleece-Back -92.5 Concrete Asphalt Primer applied Drill71bfor materwhense Sheet ener E stedpe.Tin.Jshall FX-1 rTAS10 an ragewithdrawal Membrane 4-incho.c. of 9716f or greater when tested per AN51/SPRI FX-1 or TAS105. Pre-existent cellular lightweight insulating concrete;Note:To qualify EverGuard TPO Matrix 307 Ruberoid HIMStructura LWC-99. Premium Smooth,torch- the LWICunderthis assembly,a Drill-Tec' Base Sheet Fastener(1.7 in.)or 180 2 Fleece-Back LRF-0,ribbons -112.5 Concrete Asphalt Primer applied Drill71bfor greater Sheet when perAn.JshaR achieve an average withdrawal Membrane 4-inch O.C. of 9716f or greater when tested per AN51/SPRI FX-1 or TAS105. Pre-existent cellular lightweight insulating concrete;Note:To qualify Matrix 307 Ruberoid HW EverGuard TPO GAF 2-Part Structural the LWIC under this assembly,a Drill-Tecm Base Sheet Fastener(1.7 in.)or LWC-500. Premium Smooth,torch- 180 2 Fleece-Back (spatter)or -102.5 concrete Asphalt Primer applied Drill-TecTM Base sheet Fastener E(1.7in.)shall achieve an average withdrawal Membrane OB500(spatter) of 971bf or greater when tested perAN51/5PR1 FX-1 or TA5105. Pre-existent cellular lightweight insulating concrete;Note:To qualify Matrix 307 Ruberoid HW EverGuard TPO structuralthe LWIC under this assembly,a Drill-Tec'"Base Sheet Fastener(1.7 in.)or LWC-101. Premium Smooth,torch- 540 2 Fleece-Back OB500(spatter) -357.5 concrete Drill-TecTM ease Sheet Fastener (1.7 in.)shall achieve an overage withdrawal Asphalt Primer applied of 14616for greater when tested per AN51/SPRI FX-I or TA5105. Membrane NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 114 of 156 NNEMO I etc. ..t FIBER DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF 7,.1..,d Deck Base Insulation Layer Top Insulation Layer MDP (Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) (psfl(Notes 6,7,8) (Notes 6,7,8)reedom TPO: Existing(reroof)Min.2-inch Min.1-inch EnergyGuard Polyiso Insulation, CWF-1. Tedum Plank orTectum insulation,LS EnergyGuard RA,EnergyGuard RH or EnergyGuard OB500 (Optional)Additional layers base 06500 EverGuard Freedom TPO/self -45.0 Plank RN flat or tapered adhered Existing(reroof)Min.2-inch Min.1.5-inch EnergyGuard Polyiso Insulation, CWF-2. Tedum Plank orTectum insulation,LS EnergyGuard RA,EnergyGuard RH or EnergyGuard GAF 2-Part (OptionalAdditional layers base GAF 2-Part EverGuard Freedom TPO/self -52.5 Plank orFibroplank RNflatortapered adhered EverGuard TPO: Existing(reroof)Min.2-inch Min.1-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO/#1121,TPO 3- CWF-3. Tectum Plank orTectum LS EnergyGuard RA,EnergyGuard RH or EnergyGuard OB500 insulation,flat or tapered OB500 Square,WB181 -45.0 Plank RN Existing(reroof)Min.2-inch Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO/#1121,TPO 3- CWF-4. Tedum Plank orTectum LS EnergyGuard RA,EnergyGuard RH or EnergyGuard GAF 2-Part insulation,flat or tapered GAF 2-Part Square,WB181 -52.5 Plank or Fibroplank RN New or existing(reroof) OB500,6-inch o.c. (Optional)Additional layers base OB500,6- CWF-5. Min.2-inch Tectum I Plank Min.2-inch EnergyGuard Polyiso Insulation to back-side of insulation,flat or tapered inch o.c. EverGuard TPO/#1121 -120.0 insulation New or existing(reroof) Min.2-inch EnergyGuard Polyiso Insulation, OB500,6-inch o.c. Min.0.25-inch DensDeck Prime or OB500,6- CWF-6. Min.2-inch Tectum I Plank EnergyGuard RH,EnergyGuard RM,EnergyGuard to back-side of SECUROCK Gypsum-Fiber Roof inch 0.c. EverGuard TPO/#1121 -127.5 RN or EnergyGuard Ultra insulation Board EverGuard TPO Fleece-Back Membrane: Existing(reroof)Min.2-inch Min.1-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO Fleece-Back CWF-7. Tedum Plank or Tectum LS EnergyGuard RA,EnergyGuard RH or EnergyGuard OB500 insulation,flat or tapered OB500 Membrane/LRF-0,12-inch o.c. -45.0 Plank RN Existing(reroof)Min.2-inch (Optional)Min.1-inch EnergyGuard Polyiso Min.0.25-inch SECUROCK EverGuard TPO Fleece-Back CWF-8. Tedum Plank or Tectum LS Insulation,EnergyGuard RA,EnergyGuard RH or OB500 Gypsum-Fiber Roof Board OB500 Membrane/LRF-O,12-inch o.c. -45.0 Plank EnergyGuard RN Existing(reroof)Min.2-inch Min.1-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers base EverGuard TPO Fleece-Back CWF-9. Tedum Plank orTectum LS EnergyGuard RH LRF-M insulation,flat or tapered LRF-M Membrane/LRF-M,12-inch o.c. -45.0 Plank Existing(reroof)Min.2-inch CWF-10. Tedum Plank orTectum LS (Optional)Min.1-inch EnergyGuard Polyiso LRF-M Min.0.25-inch SECUROCK LRF-M EverGuard TPO Fleece-Back -45.0 Plank Insulation,EnergyGuard RH Gypsum-Fiber Roof Board Membrane/LRF-M,12-inch o.c. Min.2-inch EnergyGuard Polyiso Insulation, OB500,6-inch o.c. EverGuard TPO Fleece-Back New or existing(reroof) (Optional)Additional layers base OB500,6- CWF-11. Min.2-inch Tectum I Plank EnergyGuard RH,EnergyGuard RM,EnergyGuard to back-side of insulation,flat or tapered inch o.c. Membrane/LRF-M or LRF-O,4- -120.0 RN insulation inch o.c.or GAF 2-Part(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMD ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 115 of 156 NNEMO I etc. ..D FIBER DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER r(Notesl&12) Deck Base Insulation Layer Top Insulation Layer MDP Type Attach Type Attach Roof Cover(Note 15) (psfl (Notes 6,7,8) (Notes 6,7,8) New or existing(reroof) Min.2-inch EnergyGuard Polyiso Insulation, OB500,6-inch o.c. Min.0.25-inch DensDeck Prime or o0 EverGuard TPO Fleece-Back O ,6- CWF-12. Min.2-inch Tectum I Plank EnergyGuard RH,EnergyGuard RM,EnergyGuard to back-side of SECUROCK Gypsum-Fiber Roof inch o.c. Membrane/UFF-M or LRF-O,4- -127.5 RN or EnergyGuard Ultra insulation Board inch o.c.or GAF 2-Part(spatter) TABLE SB:CEIVIENTITIOUS WOOD FIBER DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Base Insulation Top Insulation Layer I MDP No. (Note 1) Layer(Note 13) Type Fasteners(Note 11) Attach Roof Cover(Note 35) (psf) (Optional)One or Drill-Tec Polymer Gyptec with Drill-Tec 3" CWF-13. Existing(reroof)Min.2-inch Tectum more layers,any Min.1.5-inch EnergyGuard Gyptec Plates or Drill-Tec LD Fasteners with 1 per EverGuard Freedom TPO/self -q5.0* Plank or Tectum LS Plank combination RN or EnergyGuard Ultra Drill-Tec LD Plates;Minimum 2-inch 2.0 ft2 adhered fastener embedment. CWF-14. Existing(reroof)Min.2.5-inch more layers,any(Optional)One or Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Drill-Tec 3" 1 per EverGuard TPO/#1121,TPO 6- _q5.0* Tectum Plank or Tectum LS Plank combination RA,EnergyGuard RH Gyptec Plates(min.2-inch embedment) 2.0 ft2 Square,TPO 3-Square,WB181 New or existing(reroof/recover)Min. (Optional)One or Min.2-inch EnergyGuard Drill-Tec Locking Impact Nail(min.1.8-inch 1 per EverGuard TPO/#1121,TPO 6- CWF-15. 3-inch Tectum I Plank more layers,any Polyiso Insulation or embedment) 1.3 ft2 Square,TPO 3-Square -52.5 combination EnergyGuard RH (Optional)One or Min.2-inch EnergyGuard EverGuard TPO Fleece-Back CWF-16. New or existing(reroof/recover)Min. more layers,any Polyiso Insulation or Drill-Tec Locking Impact Nail(min.1.8-inch 1 per Membrane/LRF-M or LRF-O,4-inch -52.5 3-inch Tectum I Plank combination EnergyGuard RH embedment) 1.3 ft2 o.c.or GAF 2-Part(spatter),LRF-XF (spatter)or OB500(spatter) TABLE Sc:CEIVIENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E-2: • . MECHANICALLY ATTACHED: BONDED ROOF C• System Deck Base Sheet Roof Cover MDP No. (Note 1) Base Fasteners(Note 11) Attach (psf) Drill-Tec Twin Loc Tubes(min.1.8-inch 6-inch o.c.at min.4-inch lap CWF-17. New or existing(reroof/recover)Min.3- GAF StormSafe Anchor embedment)through Drill-Tec Twin Loc Batten and 6-inch o.c.at one center EverGuard Freedom TPO -45.0 inch Tectum I Plank Sheet Bar row TABLE SO:CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System No. Deck(Notes 18,12) Primer/Treatment Roof Cover(Note 15) MDP(psf) New or existing(reroof)Min.2-inch Tectum I EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter)in CWF-18. Plank None accordance with GAF published installation instructions for Tectum -127.5 applications NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 116 of 156 NNEMOjetc. TABLE 6A:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer MDP No. (Notes 1&22) Type Attach Type Attach Roof Cover(Note 15) (psf) (Notes 6,7,8) (Notes 6,7,8) 7 EverGuard Freedom TPO: G-1. Existing poured gypsum (Optional)Min.1.5-inch EnergyGuard RA,EnergyGuard OB500 Min.0.25-inch SECUROCK Gypsum- OB500 EverGuard Freedom TPO/self _135.0 or gypsum plank RH or EnergyGuard RN Fiber Roof Board adhered G 2 Existing poured gypsum Min.1-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layer of base OB500 EverGuard Freedom TPO/self _142.5 or gypsum plank EnergyGuard Ultra insulation adhered G-3. Existing poured gypsum Min.1-inch EnergyGuard RA OB500 (Optional)Additional layer of base OB500 EverGuard Freedom TPO/self -187.5 or gypsum plank insulation adhered G 4 Existing poured gypsum Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer of base GAF 2-Part EverGuard Freedom TPO/self -142.5 or gypsum plank EnergyGuard Ultra insulation adhered G-5. Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RH or GAF 2-Part Min.0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard Freedom TPO/self _257.5 or gypsum plank EnergyGuard RN Fiber Roof Board adhered EverGuard TPO/EverGuard TPO#1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: lu- Existing poured gypsum Min.0.25-inch DensDeck or DensDeck EverGuard TPO/#1121,TPO 3- G-6. or gypsum plank Min.2-inch,min.2.0 pcf,Insulfoam EPS 08500 Prime OB500 Square -120.0 Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Min.0.25-inch DensDeck or DensDeck OB500 EverGuard TPO/#1121,TPO 3- 130.0 G 7. or gypsum plank EnergyGuard RN OB500 Prime Square - G 8 Existing poured gypsum (Optional)Min.1.5-inch EnergyGuard RA,EnergyGuard OB500 Min.0.25-inch SECUROCK Gypsum- OB500 EverGuard TPO/#1121,TPO 3- _135.0 or gypsum plank RH or EnergyGuard RN Fiber Roof Board Square Existing poured gypsum Min.1-inch EnergyGuard Polyiso Insulation, (Optional)Additional layer of base EverGuard TPO/#1121,TPO 3- G-9. or gypsum plank EnergyGuard Ultra OB500 insulation OB500 Square -270.0 Existing poured gypsum Min (Optional)Additional layer of base OB500 EverGuard TPO/#1121,TPO 3- -387.5 G-10. or gypsum plank .1-inch EnergyGuard RA OB500 insulation Square G-11. Existing poured gypsum Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Min.0.25-inch DensDeck Prime or GAF 2-Part EverGuard TPO/#1121,TPO 3- 87 5 or gypsum plank SECUROCK Gypsum-Fiber Roof Board Square Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Min.0.25-inch DensDeck or DensDeck EverGuard TPO/#1121,TPO 3- G-12. or gypsum plank EnergyGuard RN or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Prime GAF 2-Part Square -130.0 Insulfoam EPS G-13. Existing poured gypsum One or more layers,min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard TPO/#1121,TPO 3- -180.0 or gypsum plank Insulfoam EPS Fiber Roof Board Square G-14. Existing poured gypsum One or more layers,min.1.5-inch thick,min.2.0 pcf GAF 2-Part Min.0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard TPO/#1121,TPO 3- -240.0 or gypsum plank Insulfoam EPS Fiber Roof Board Square G-15. Existing poured gypsum Min.2-inch EnergyGuard RA,EnergyGuard RH or GAF 2-Part Min.0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard TPO/#1121,TPO 3- _247.5 or gypsum plank EnergyGuard RN Fiber Roof Board Square G-16. Existing poured gypsum Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer of base GAF 2-Part EverGuard TPO/#1121,TPO 3- -257.5 or gypsum plank EnergyGuard Ultra insulation Square EverGuard TPO/EverGuard WB181 Bonding Adhesive: NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 117 of 156 NNEMO I etc. TABLE 6A:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF 7G-17. 7E.istingo Deck Base Insulation Layer Top Insulation Layer MDP Ntes 1&12) Type Attach Type Attach Roof Cover(Note 15) (Psf) (Notes 6,7,8) (Notes 6,7,8) poured gypsum Min.2-inch,min.2.0 pcf,Insulfoam EPS OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/WB181 -120.0 sum plank G-18. Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RH or OB500 Min.0.25-inch DensDeck Prime OB500 EverGuard TPO/WB181 -130.0 or gypsum plank EnergyGuard RN G-19. Existing poured gypsum Min.1.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional)Additional layer of base OB500 EverGuard TPO/WB181 -135.0 or gypsum plank EnergyGuard Ultra insulation G-20. Existing poured gypsum Min.1-inch EnergyGuard RA OB500 (Optional)Additional layer of base OB500 EverGuard TPO/WB181 -210.0 or gypsum plank insulation G-21. Existing poured gypsum Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Min.0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO/WB181 -87.5 or gypsum plank Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RH or G 22. or gypsum plank EnergyGuard RN or Min.1.5-inch thick,min.1.5 pcf GAF 2-Part Min.0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO/WB181 -130.0 Insulfoam EPS Existing poured gypsum Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layer of base G-23. or gypsum plank EnergyGuard Ultra GAF 2-Part insulation GAF 2-Part EverGuard TPO/WB181 -257.5 EverGuard TPO/EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RH, Min.0.25-inch DensDeck Prime or EverGuard TPO/TPO 6-Square, G 24. or gypsum plank EnergyGuard RN or EnergyGuard Ultra,min.2-inch,min. OB500 SECUROCK Gypsum-Fiber Roof Board OB500 TPO 3-Square -45.0 2.0 pcf,Insulfoam EPS G-25. Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RN or OB500 (Optional)Additional layer of base OB500 EverGuard TPO/TPO 6-Square, -135.0 or gypsum plank EnergyGuard Ultra insulation TPO 3-Square Existing poured gypsum Min.1.5-inch EnergyGuard RA,EnergyGuard RH or Min.0.25-inch DensDeck Prime or EverGuard TPO/TPO 6-Square, G-26. or gypsum plank EnergyGuard RN or min.1.5-inch thick,min.1.25 pcf GAF 2-Part SECUROCK Gypsum-Fiber Roof Board GAF 2-Part TPO 3-Square -45.0 Insulfoam EPS Existing poured gypsum Min (Optional)Additional layer of base EverGuard TPO/TPO 6-Square, G 27. or gypsum plank .1.5-inch EnergyGuard RA,EnergyGuard RN GAF 2-Part insulation GAF 2-Part TPO 3-Square -257.5 EverGuard TPO Fleece-Back Membrane: G 28 Existing poured gypsum Min.1-inch EnergyGuard RH OB500 (Optional)Additional layer of base OB500 EverGuard TPO Fleece-Back -75.0 or gypsum plank insulation Membrane/LRF-O,6-inch o.c. EverGuard TPO Fleece-Back G 29 Existing poured gypsum Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer of base GAF 2-Part Membrane/GAF 2-Part -257.5 or gypsum plank EnergyGuard Ultra insulation (spatter),LRF-XF(spatter)or OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FLS293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 118 of 156 NNEMO I etc. TABLE 6B:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEMTYPEA-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation System Deck Attach Roof Cover MDP No. (Note 1) Type Fasteners(Note 21) Attach Temp Roof Type Attach Type (Notes (Note 15) (psf) 6,7,8) Existing Min.0.25-inch DensDeck GAFGLAS Drill-Tec Base Sheet Ruberoid 25 EverGuard poured 9-inch o.c.in the min.2- Min.1.5-inch Prime or SECUROCK #75 Base Fastener(1.2 in.)or Smooth,SBS H W TPO/#1121, G-30. gypsum inch laps and 18-inch o.c. EnergyGuard RA, Gypsum-Fiber Roof Board Sheet orTri- Drill-Tec Base Sheet Smooth,Ruberoid OB500 OB500 TPO 6-Square, -45.0* or in two,equally spaced EnergyGuard RH, or min.0.5-inch Ply#75 Base Fastener E(1.2 in.) Torch Smooth or TPO 3-Square, gypsum Sheet (W/D>105 Ibf) center rows Tri-Ply APP Smooth EnergyGuard RN Structodek HD Fiberboard WB181 plank Roof Insulation TABLE 6c:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEMTYPEB-1:MECHANICALLY ATTACHED BASE • BONDED TOP INSULATION,BONDED ROOCOVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten(Note 11) Attach Type Attach Roof Cover(Note 15) (psf) Attach EverGuard Freedom TPO: Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-31. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 2.0 ft2 EnergyGuard Ultra LRF-M TPO/self adhered -45.0* gypsum plank Ultra (Min.2-inch embedment) Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-32. gypsum or Drill-Tec 3"Gyptec Plates LRF-M -45.0 gypsum plank Insulation,EnergyGuard Ultra (Min.2-inch embedment) 2.9 ft2 EnergyGuard Ultra TPO/self adhered Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Optional min.0.5-inch EnergyGuard Polyiso EverGuard Freedom G-33. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 2.0 ft2 Insulation,EnergyGuard Ultra followed by min. LRF-M TPO/self adhered -45.0* gypsum plank Ultra (Min.2-inch embedment) 0.25-inch SECUROCK Gypsum-Fiber Roof Board Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Optional min.0.5-inch EnergyGuard Polyiso EverGuard Freedom G-34. gypsum or Insulation,EnergyGuard Ultra Drill-Tec 3"Gyptec Plates 2.9 ft2 Insulation,EnergyGuard Ultra followed by min. LRF-M TPO/self adhered -45.0* gypsum plank (Min.2-inch embedment) 0.25-inch SECUROCK Gypsum-Fiber Roof Board Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per EverGuard Freedom G-35. gypsum or Drill-Tec 3"Gyptec Plates Min.0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M -45.0* gypsum plank Insulation,EnergyGuard Ultra (Min.2-inch embedment) 3.2 ft2 TPO/self adhered Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-36. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 2.0 ft2 EnergyGuard Ultra or min.1.5-inch EnergyGuard RH OB500 TPO/self adhered -45.0* gypsum plank Ultra or EnergyGuard RH (Min.2-inch embedment) Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-37. gypsum or Insulation,EnergyGuard Ultra or Drill-Tec 3"Gyptec Plates OB500 -45.0* gypsum plank EnergyGuard RH (Min.2-inch embedment) 2.9 ft2 EnergyGuard Ultra or min.1.5-inch EnergyGuard RH TPO/self adhered NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 119 of 156 NNEMO I etc. TABLE 6c:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer System Deck Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (psf) (Notes 6,7,8) Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Optional min.0.5-inch EnergyGuard Polyiso G-38. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 1 per Insulation,EnergyGuard Ultra or min.1.5-inch OB500 EverGuard Freedom _45.0* gypsum plank Ultra or EnergyGuard RH (Min.2-inch embedment) 2.0 ft2 EnergyGuard RH followed by min.0.25-inch TPO/self adhered SECUROCK Gypsum-Fiber Roof Board Optional min.0.5-inch EnergyGuard Polyiso Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with G-39. gypsum or Insulation,EnergyGuard Ultra or Drill-Tec 3"Gyptec Plates .per Insulation,EnergyGuard Ultra or min. inchch OB500 EverGuard Freedom _q5.0* gypsum plank EnergyGuard RH (Min.2-inch embedment) 29 ft2 EnergyGuard RH followed min.0.25-inch TPO/self adhered SECUROCK Gypsum-Fiber Roof Board Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per EverGuard Freedom G-40. gypsum or Drill-Tec 3"Gyptec Plates Min.0.25-inch SECUROCK Gypsum-Fiber Roof Board 0B500 -45.0* gypsum plank Insulation,EnergyGuard Ultra (Min.2-inch embedment) 3.2 ft2TPO/self adhered EverGuard TPO: 121, Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard re, /O 3- G-41. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 2.0 ft2 EnergyGuard Ultra LRF-M TPO 6-Square,TPO 3- -45.0* gypsum plank Ultra (Min.2-inch embedment) Square,WB181 Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/#1121, G-42. gypsum or EnergyGuard Ultra Drill-Tec 3"Gyptec Plates 9 ft� EnergyGuard Ultra LRF-M TPO 6-Square,TPO 3- -45.0* Insulation, 2 gypsum plank (Min.2-inch embedment) Square,WB181 Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Optional min.0.5-inch EnergyGuard Polyiso EverGuard TPO/#1121, G-43. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 1 per Insulation,EnergyGuard Ultra followed by min. LRF-M TPO 6-Square,TPO 3- -45.0* gypsum plank Ultra 2.0 ft2 inch DensDeck Prime or SECUROCK Gypsum- (Min.2-inch embedment) Fiber Fiber Roof Board Square,W6181 5-inch EnergyGuard Polyiso 0. Existing poured Drill-Tec Polymer Gyptec with Optional min. EverGuard TPO/#1121, Min.2-inch EnergyGuard Polyiso 1 per Insulation,EnergyGuard Ultra followed by min. G-44. gypsum plank Insulation,EnergyGuard Ultra (Min. 3"Gyptec Plates 2.9 ft2 0.25-inch DensDeck Prime or SECUROCK Gypsum- LRF-M SquTPOare, 6e,WB e,TPO 3- -45.0* gypsum plank (Min.2-inch embedment) Fiber Roof Board Square,WB181 Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/#1121, G-45. gypsum or Drill-Tec 3"Gyptec Plates LRF-M TPO 6-Square,TPO 3- -45.0* gypsum plank Insulation,EnergyGuard Ultra (Min.2-inch embedment) 3.2 ft2 Gypsum-Fiber Roof Board Square,WB181 Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 2 EverGuard TPO/#1121, G-46. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates .per Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 TPO 6-Square,TPO 3- -45.0* gypsum plank Ultra or EnergyGuard RH (Min.2-inch embedment) 0 ft2 EnergyGuard Ultra or min.1.5-inch EnergyGuard RH Square,WB181 Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/#1121, G-47. gypsum or Insulation,EnergyGuard Ultra or Drill-Tec 3"Gyptec Plates 2.9 ft2 EnergyGuard Ultra or min.1.5-inch EnergyGuard RH OB500 TPO 6-Square,TPO 3- -45.0* gypsum plank EnergyGuard RH (Min.2-inch embedment) Square,WB181 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 120 of 156 NNEMO I etc. TABLE 6c:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer System Deck M Attach Roof Cover(Note 15) DP No. (Note 1) Type Fasten(Note 11) Attach Type (psf) (Notes 6,7,8) Optional min.0.5-inch EnergyGuard Polyiso Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Insulation,EnergyGuard Ultra or min.1.5-inch EverGuard TPO/#1121, G-48. sum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates .per EnergyGuard RH followed b min.0.25-inch OBS00 TPO 6-Square,TPO 3- -45.0* gypsum Y gY Yp 2.0 ft2 gY Y 9 gypsum plank Ultra or EnergyGuard RH (Min.2-inch embedment) DensDeck Prime or SECUROCK Gypsum-Fiber Roof Square,WB181 Board Optional min.0.5-inch EnergyGuard Polyiso Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Insulation,EnergyGuard Ultra or min.1.5-inch EverGuard TPO/#1121, G-49. gypsum or Insulation,EnergyGuard Ultra or Drill-Tec 3"Gyptec Plates 2.9 ft2 EnergyGuard RH followed by min.0.25-inch OB500 TPO 6-Square,TPO 3- -45.0* gypsum plank EnergyGuard RH (Min.2-inch embedment) DensDeck Prime or SECUROCK Gypsum-Fiber Roof Square,WB181 Board Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min.0.25-inch DensDeck Prime or SECUROCK EverGuard TPO/#1121, G-50. gypsum or Drill-Tec 3"Gyptec Plates OBS00 TPO 6-Square,TPO 3- -45.0* gypsum plank Insulation,EnergyGuard Ultra (Min.2-inch embedment) 3.2 ft2Gypsum-Fiber Roof Board Square,WB181 EverGuard TPO Fleece-Back Membrane: PO Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with EverGuard ran Fleece- G-51. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M Back Membrane/ -45.0* gypsum plank Ultra (Min.2-inch embedment) 2.0 ft2 EnergyGuard Ultra WB181 or LRF-M or LRF-O,12-inch o.c. Existing poured Drill-Tec Polymer Gyptec with EverGuard ran Fleece- Min.2-inch EnergyGuard Polyiso Drill-Tec 3"Gyptec Plates 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M Back Membrane/ -45.0* G-52. gypsum or gypsum plank Insulation,EnergyGuard Ultra (Min.ec 3" embedment) 2.9 ft2 EnergyGuard Ultra WB181 or LRF-M or LRF-O,12-inch o.c. Optional min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Insulation,EnergyGuard Ultra followed by min. Back Membrane/ G-53. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 2.0 W 0.25-inch DensDeck Prime or SECUROCK Gypsum- LRF-M WB181 or LRF-M or -45.0* gypsum plank Ultra (Min.2-inch embedment) Fiber Roof Board LRF-O,12-inch o.c. Existing poured Drill-Tec Polymer Gyptec with Optional min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Min.2-inch EnergyGuard Polyiso 1 per Insulation,EnergyGuard Ultra followed by min. Back Membrane/ G-54. gypsum or Insulation,EnergyGuard Ultra Drill-Tec 3"Gyptec Plates 2 9 ft2 0.25-inch DensDeck Prime or SECUROCK Gypsum- LRF-M WB181 or LRF-M or -45.0* gypsum plank (Min.2-inch embedment) Fiber Roof Board LRF-O,12-inch o.c. Existing poured Drill-Tec Polymer Gyptec with EverGuard TPO Fleece- G-55. gypsum or Min.2-inch EnergyGuard Polyiso Drill-Tec 3"Gyptec Plates 1 per Min.0.25-inch DensDeck Prime or SECUROCK LRF-M Back Membrane/ -45.0* gypsum plank Insulation,EnergyGuard Ultra (Min.2-inch embedment) 3.2 W Gypsum-Fiber Roof Board WB181 or LRF-M or LRF-O,12-inch o.c. Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with EverGuard TPO Fleece- 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, Back Membrane/ G-56. gypsum plank Polyiso Insulation,EnergyGuard (Min. 3"Gyptec Plates 2.0 ft2 EnergyGuard Ultra or min.1.5-inch EnergyGuard RH OB500 WB181 or LRF-M or -45.0* gypsum plank Ultra or EnergyGuard RH (Min.2-inch embedment) LRF-O,12-inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 121 of 156 NNEMO I etc. TABLE 6c:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE B-1:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer System Deck Attach Roof Cover(Note 15) MDP No. (Note 1) Type Fasten(Note 11) Attach Type (psf) (Notes 6,7,8) Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with EverGuard TPO Fleece- 1 per Min.0.5-inch EnergyGuard Polyiso Insulation, Back Membrane/ G-57. gypsum or plank EnergyGuard RH (Min Insulation,EnergyGuard Ultra or (Min. 3"Gyptec Plates.2-inch embedment) 2.9 ft2 EnergyGuard Ultra or min.1.5-inch EnergyGuard RH OB500 WB181 or LRF-M or -45.0* gypsum plank LRF-O,12-inch o.c. Optional min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Existing poured Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Insulation,EnergyGuard Ultra or min.1.5-inch Back Membrane/ G-58. gypsum or Polyiso Insulation,EnergyGuard Drill-Tec 3"Gyptec Plates 2.0 ft2 EnergyGuard RH followed by min.0.25-inch OB500 WB181 or LRF-M or -45.0* gypsum plank Ultra or EnergyGuard RH (Min.2-inch embedment) DensDeck Prime or SECUROCK Gypsum-Fiber Roof LRF-O,12-inch o.c. Board Optional min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Insulation,EnergyGuard Ultra or min.1.5-inch Back Membrane/ G-59. gypsum or Insulation,EnergyGuard Ultra or Drill-Tec 3"Gyptec Plates 2.9 ft2 EnergyGuard RH followed by min.0.25-inch OB500 WB181 or LRF-M or -45.0* gypsum plank EnergyGuard RH (Min.2-inch embedment) DensDeck Prime or SECUROCK Gypsum-Fiber Roof LRF-O,12-inch o.c. Board EverGuard TPO Fleece- Existing poured Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min.0.25-inch DensDeck Prime or SECUROCK Back Membrane/ G-60. gypsum or Insulation,EnergyGuard Ultra Drill-Tec 3"Gyptec Plates 3.2 ft2 Gypsum-Fiber Roof Board OB500 WB181 or LRF-M or -45.0* gypsum plank (Min.2-inch embedment) LRF-O,12-inch o.c. TABLE 6D:GYPSUM rREROOF(TEAR-OFF) SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) (Note 13) Type Fasteners(Note 21) Attach Roof Cover(Note 15) (Psf) Existing poured (Optional)One or Drill-Tec Polymer Gyptec with Drill-Tec 3"Gyptec Plates G-61. gypsum or gypsum more layers,any Min.1.5-inch EnergyGuard RN or or Drill-Tec LD Fasteners with Drill-Tec LD Plates 1 per EverGuard Freedom TP0/self -45.0* plank combination EnergyGuard Ultra (Minimum 2-inch fastener embedment) 2.0 ft adhered Existing poured (Optional)One or Min.1.5-inch EnergyGuard G-62. sum or sum more layers,an Polyiso Insulation,EnergyGuard (Min. Polymer Gyptec with Drill-Tec 3"Gyptec Plates 1 per EverGuard Freedom TPO/self -45.0* gyp �'P a y y gy (Min.2-inch embedment) 2.0 ft' adhered plank combination Ultra,EnergyGuard RH Existing poured (Optional)One or Drill-Tec Polymer Gyptec with Drill-Tec 3"Gyptec Plates G-63. gypsum or gypsum more layers,any Min.2-inch EnergyGuard Polyiso (Min.2-inch embedment);8 parts per min.4 x 8 ft 1 per EverGuard Freedom TPO/self -45.0* plank combination Insulation,EnergyGuard Ultra board with parts installed 24-inch o.c.in two parallel 4.0 ft2 adhered rows,12 inches from the 8 ft edges of the board Existing poured (Optional)One or G-64. gypsum or gypsum more layers,any Min.2-inch EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3"Gyptec Plates 1 per 2 EverGuard Freedom TPO/self -45.0* plank combination (Min.2-inch embedment) 2.9 ft adhered 11 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 122 of 156 NNEMO I etc. ATTACHEDTABLE 6D:GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE C-1:MECHANICALLY INSULATION,BONDED ROOF System Deck Base Insulation Layer Top Insulation Layer MOP No. (Note 1) (Note 13) Type Fasteners(Note 11) Attach Roof Cover(Note 15) (Psf) Existing poured (Optional)One or Min.1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Drill-Tec 3"Gyptec Plates 1 per EverGuard TPO/#1121,TPO 6- G-65. gypsum or gypsum more layers,any Polyiso Insulation,EnergyGuard (Min.2-inch embedment) 2.0 ft2 Square,TPO 3-Square,WB181 -45.0* plank combination Ultra,EnergyGuard RH Existing poured (Optional)One or Drill-Tec Polymer Gyptec with Drill-Tec 3"Gyptec Plates G-66. gypsum or gypsum more layers,any Min.2-inch EnergyGuard Polyiso (Min.2-inch embedment);8 parts per min.4 x 8 ft 1 per EverGuard TPO/#1121,TPO 6- _45.0* plank combination Insulation,EnergyGuard Ultra board with parts installed 24-inch o.c.in two parallel 4.0 ft2 Square,TPO 3-Square,WB181 rows,12 inches from the 8 ft edges of the board Existing poured (Optional)One or G-67. gypsum or gypsum more layers,any Min.2-inch EnergyGuard RH (Min. Polymer Gyptec with Drill-Tec 3"Gyptec Plates 1 per EverGuard 3-/#1123-Square, B18PO 6- _45.0* plank combination (Min.2-inch embedment) 2.9 ft2 Square,TPO 3-Square,W8181 Existing poured (Optional)One or Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back Dri .2-i Polymer Gyptec with Drill-Tec 3"Gyptec Plates 1 per G-68. gypsum or gypsum more layers,any Polyiso Insulation,EnergyGuard (Min.2-inch embedment) 2.0 ft2 Membrane/W8181 or LRF-M or -45.0* plank combination Ultra,EnergyGuard RH LRF-0,12-inch o.c. Existing poured (Optional)One or Min.2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with Drill-Tec 3"Gyptec Plates 1 per EverGuard TPO Fleece-Back G-69. gypsum or gypsum more layers,any Insulation,EnergyGuard Ultra, (Min.2-inch embedment) 2.9 ft2 Membrane/WB181 or LRF-M or -45.0* plank combination EnergyGuard RH LRF-0,12-inch o.c. Existing poured (Optional)One or Min.2-inch EnergyGuard Polyiso Drill-Tec Locking Impact Nail(minimum withdrawal 1 per EverGuard TPO/#1121,TPO 6- G-70. gypsum or gypsum more layers,any Insulation or EnergyGuard RH resistance at slated embedment>1401bf) 1.3 ft2 Square,TPO 3-Square -52.5 plank I combination EverGuard TPO Fleece-Back Existing poured (Optional)One or Min.2-inch EnergyGuard Polyiso Drill-Tec Locking Impact Nail(minimum withdrawal 1 per Membrane/LRF-M or LRF-O,4- G-71. gypsum or gypsum more layers,any Insulation or EnergyGuard RH resistance at slated embedment>1401bf) 1.3 ft2 inch o.c.or GAF 2-Part(spatter), -52.5 plank combination LRF-XF(spatter)or OB500(spatter) TABLE 6E:GYPSUM• CONSTRUCTION, •• SYSTEM TYPE E-2: • • MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover MDP No. (Note 1) Base Fasteners(Note 22) Attach (Psf) Existing poured gypsum or GAF StormSafe Anchor Drill-Tec Twin Loc Tubes(minimum withdrawal resistance at slated 6-inch o.c.at min.4-inch lap and EverGuard Freedom G 72. -45.0 gypsum plank Sheet embedment>83 Ibf)through Drill-Tec Twin Loc Batten Bar 6-inch o.c.at one center row TPO TABLE 6F:GYPSUM• •• • SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System No. Deck(Notes 1&12) Primer/Treatment Roof Cover(Note 15) MDP(psf) G-73. Existing poured gypsum or gypsum plank None EverGuard TPO Fleece-Back Membrane/WB181 -90.0 G-74. Existing poured gypsum or gypsum plank None EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter) -95.0 G-75. Existing poured gypsum or gypsum plank None EverGuard TPO Fleece-Back Membrane/OB500(spatter) -280.0 G-76. Existing poured gypsum or gypsum plank SureBond Primer at 0.5 gal/square EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter) -327.5 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 71h Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 123 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer7-7177 Top Insulation Layer System No. Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) (Ps� (Notes 6,7,8) (Notes 6,7,8) EverGuard Freedom TPO: R-1. Existing smooth-or granule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard Freedom TPO/ _45.0 granule-surfaced modified bitumen EnergyGuard Ultra self adhered Existing smooth-or granule-surfaced BUR;smooth-or R 2 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard Freedom TPO/ _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation self adhered gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-3. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard Freedom TPO/ _157.5 BUR,brushed/spudded and vacuumed to remove loose 6-inch o.c. of base insulation 6-inch o.c. self adhered gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-4. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard Freedom TPO/ _200.0 BUR,brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. self adhered gravel,over structural concrete deck R-5. Existing smooth-surface modified bitumen over struct. (Optional)Min.1.5-inch EnergyGuard RA, GAF 2-Part Min.0.25-inch SECUROCK GAF 2-Part EverGuard Freedom TPO/ 222 5 concrete deck EnergyGuard RH or EnergyGuard RN Gypsum-Fiber Roof Board self adhered R-6. Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part None N/A EverGuard Freedom TPO/ _245.0 bitumen overstruct.concrete deck Board self adhered Min.1.5-inch EnergyGuard RA,EnergyGuard RH GAF 2-Part Min.0.25-inch SECUROCK EverGuard Freedom TPO -262.5 / R-7. Existing smooth-surfaced BUR over struct.concrete deck or EnergyGuard RN Gypsum-Fiber Roof Board GAF 2-Part self adhered Existing granule-surfaced modified bitumen over struct. Min.1.5-inch EnergyGuard RA,EnergyGuard RH GAF 2-Part Min.0.25-inch SECUROCK EverGuard Freedom TPO -270.0 / R-8. concrete deck or EnergyGuard RN Gypsum-Fiber Roof Board GAF 2-Part self adhered R9 Existing smooth-or granule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard Freedom TPO/ -45.0 granule-surfaced modified bitumen EnergyGuard Ultra self adhered Existing smooth-or granule-surfaced BUR;smooth-or R-10. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard Freedom TPO/ _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation self adhered gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-11. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnerGuard Poliso Insulation LRF-M,6- (Optional)Additional layer LRF-M,6- EverGuard Freedom TPO gy y / _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. self adhered gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-12. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,4- (Optional)Additional layer LRF-M,4- EverGuard Freedom TPO/ _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. self adhered gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FLS293-1146 Certificate of Authorization#32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 MEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 124 of 156 NNEMO etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard Freedom TPO/ R-13. granule-surfaced modified bitumen over structural Insulation or min.1.5-inch EnergyGuard RH LRF-M EnergyGuard HD Polyiso LRF-M self adhered -75.0 concrete deck Insulation,EnergyGuard HD Plus Polyiso Insulation Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Min.0.25-inch EverGuard Freedom TPO/ R-14. granule-surfaced modified bitumen over structural EnergyGuard Ultra LRF-M SECUROCK Gypsum-Fiber LRF-M self adhered 75.0 concrete deck Roof Board Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Min.0.25-inch EverGuard Freedom TPO/ R-15. granule-surfaced SBS or granule-surfaced APP modified EnergyGuard Ultra LRF-M SECUROCK Gypsum-Fiber LRF-M self adhered -225.0 bitumen overstructural concrete deck Roof Board Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO/ R-16. granule-surfaced modified bitumen EnergyGuard Ultra LRF-XF None N/A self adhered -45.0 Existing smooth-or granule-surfaced BUR;smooth-or R-17. granule surfaced SBS modified bitumen orgravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard Freedom TPO/ -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation self adhered gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-18. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,6- (Optional)Additional layer LRF-XF,6- EverGuard Freedom TPO/ _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. self adhered gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-19. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,4- (Optional)Additional layer LRF-XF,4- EverGuard Freedom TPO/ _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. self adhered gravel,over structural concrete deck R-20. Existing smooth-surface modified bitumen over struct. (Optional)Min.1.5-inch EnergyGuard RA or LRF-XF Min.0.25-inch SECUROCK LRF-XF EverGuard Freedom TPO/ 222 5 concrete deck EnergyGuard RH Gypsum-Fiber Roof Board self adhered R-21. Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF None LRF-XF EverGuard Freedom TPO/ -245.0 bitumen overstruct.concrete deck Board self adhered Min.1.5-inch EnergyGuard RA or EnergyGuard LRF-XF Min.0.25-inch SECUROCK LRF-XF EverGuard Freedom TPO -262.5 / R-22. Existing smooth-surfaced BUR over struct.concrete deck RH Gypsum-Fiber Roof Board self adhered R-23. Existing granule-surfaced modified bitumen over struct. Min.1.5-inch EnergyGuard RA or EnergyGuard LRF-XF Min.0.25-inch SECUROCK LRF-XF EverGuard Freedom TPO/ -270.0 concrete deck RH Gypsum-Fiber Roof Board self adhered Existing smooth-orgranule-surfaced BUR;smooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO/ R-24. granule-surfaced SBS modified bitumen or granule- EnergyGuard Ultra OB500 None N/A self adhered -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-25. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OB500 EverGuard Freedom TPO/ -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation self adhered gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 125 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layer EverGuard Freedom TPO/ R-26. granule-surfaced SB5 modified bitumen or granule- EnergyGuard Ultra OB500 of base insulation OB500 self adhered -120.0 surfaced APP modified bitumen over struct.concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R 27 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnerGuard Poliso Insulation OB500,6- (Optional)Additional layer OB500,6- EverGuard Freedom TPO gy y / _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. self adhered gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R 26 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnerGuard Poliso Insulation OB500,4- (Optional)Additional layer OB500,4- EverGuard Freedom TPO gy y / _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. self adhered gravel,over structural concrete deck Min.0.5-inch EnergyGuard Existing smooth-or granule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard Freedom TPO/ R-29. granule-surfaced SBS modified bitumen or granule- OB500 EnergyGuard HD Polyiso OB5o0 -97.5 surfaced APP modified bitumen over struct.concrete deck Insulation or min.1.5-inch EnergyGuard RH Insulation,EnergyGuard HD self adhered Plus Polyiso Insulation Existing smooth-or granule-surfaced BUR;smooth-or (Optional)Min.1.5-inch EnergyGuard RA, Min.0.25-inch SECUROCK EverGuard Freedom TPO/ R-30. granule-surfaced SBS modified bitumen or granule- EnergyGuard RH,EnergyGuard RN OB500 Gypsum-Fiber Roof Board OB500 self adhered -120.0 surfaced APP modified bitumen over struct.concrete deck Existing smooth-or granule-surfaced BUR;smooth-or (Optional)Min.0.25-Inch R-31. granule-surfaced SBS modified bitumen or granule- Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 SECUROCK Gypsum-Fiber OB500 EverGuard Freedom TPO/ -225.0 surfaced APP modified bitumen overstructural concrete EnergyGuard Ultra Roof Board self adhered deck EverGuard TPO in EverGuard TPO#1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: (Optional)Min.0.25-inch R-32. Existing asphalt BUR or mineral surface cap sheet Min.1.5-inch EnergyGuard RA,EnergyGuard RH Hot Asphalt DensDeck Prime or min. Hot asphalt EverGuard TPO/#1121, -45.0 or EnergyGuard RN 7/16-inch OSB TPO 3-Square R-33. Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO #1121, -45.0 granule-surfaced modified bitumen EnergyGuard Ultra TPO 3-Square Existing smooth-or granule-surfaced BUR;smooth-or R-34. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/#1121, -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-35. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/#1121, -157.5 BUR,brushed/spudded and vacuumed to remove loose 6-inch o.c. of base insulation 6-inch o.c. TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-36. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/#1121, -200.0 BUR,brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. TPO 3-Square gravel,overstructural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 126 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers EverGuard TPO/#1121, R-37. granule-surfaced SB5 or APP modified bitumen over EnergyGuard Ultra,EnergyGuard RH, GAF 2-Part base insulation GAF 2-Part TPO 3-Square -180.0 structural concrete deck EnergyGuard RN Existing smooth-surfaced modified bitumen overstruct. Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layer EverGuard TPO/#1121, R-38. GAF 2-Part concrete deck EnergyGuard Ultra of base insulation GAF 2-Part TPO 3-Square 222.5 R-39. Existing smooth-surface BUR over struct.concrete deck Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/#1121, -262.5 EnergyGuard Ultra of base insulation TPO 3-Square Existing granule-surface modified bitumen overstruct. Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/#1121, -270.0 R-40. concrete deck EnergyGuard Ultra of base insulation TPO 3-Square Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1.5-inch EnergyGuard RA,EnergyGuard RH Min.0.25-inch DensDeck or EverGuard TPO/#1121, R-41. granule-surfaced SBS orgranule-surfaced APP modified or EnergyGuard RN or Min.1.5-inch thick,min. GAF 2-Part DensDeck Prime GAF 2-Part TPO 3-Square -130.0 bitumen overstructural concrete deck 1.5 pcf Insulfoam EPS Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.25-inch DensDeck EverGuard TPO/#1121, R-42. granule-surfaced SBS or granule-surfaced APP modified Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Prime or SECUROCK GAF 2-Part TPO 3-Square 87.5 bitumen overstructural concrete deck Gypsum-Fiber Roof Board Existing smooth-orgranule-surfaced BUR orsmooth-or One or more layers,min.1.5-inch thick,min. Min.0.25-inch SECUROCK EverGuard TPO/#1121, R-43. granule-surfaced SB5 or granule-surfaced APP modified 1.5 pcf Insulfoam EPS GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO 3-Square -180.0 bitumen overstructural concrete deck (Optional)Min.2-inch EnergyGuard RA, R 44 Existing smooth-surfaced modified bitumen over struct. EnergyGuard RH or EnergyGuard RN or min. GAF 2-Part Min.um-Finch Roof Board GAF 2-Part EverGuard TPO/#1121, 222 5 concrete deck Gypsum-Fiber Roof Board TPO 3-Square 1.5-inch thick,min.2.0 pcf Insulfoam EPS Existing smooth-surface BUR or granule-surface modified One or more layers,min.1.5-inch thick,min. Min.0.25-inch SECUROCK EverGuard TPO/#1121, R-45. bitumen over struct.concrete deck 2.0 pcf Insulfoam EPS GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO 3-Square -240.0 R-46. Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part None N/A EverGuard TPO/#1121, _245.0 bitumen over struct.concrete deck Board TPO 3-Square Existing smooth-surface BUR orgranule surface modified Min.2-inch EnergyGuard RA,EnergyGuard RH Min.0.25-inch SECUROCK EverGuard TPO/#1121, R-47. bitumen over struct.concrete deck or EnergyGuard RN GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO 3-Square -247.5 R 48 Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO/#1121, -45.0 granule-surfaced modified bitumen EnergyGuard Ultra TPO 3-Square Existing smooth-or granule-surfaced BUR;smooth-or R-49. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard TPO/#1121, _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation TPO 3-Square gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-50. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,6- (Optional)Additional layer LRF-M,6- EverGuard TPO/#1121, _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO 3-Square gravel,overstructural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7t^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMo ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 127 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or R-51. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,4- (Optional)Additional layer LRF-M,4- EverGuard TPO/#1121, _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO 3-Square gravel,overstructural concrete deck Min.0.5-inch EnergyGuard Existing smooth-or granule-surfaced BUR or smooth-or RH H D Polyiso Insulation, (Optional)Min.min. EnergyGuard Polyiso EverGuard TPO/#1121, R-52. granule-surfaced modified bitumen over structural Insulation or min.1.5-inch EnergyGuard RH LRF-M EnergyGuard HD Polyiso LRF-M TPO 3-Square -75.0 concrete deck Insulation,EnergyGuard HD Plus Polyiso Insulation Existing smooth-or granule-surfaced BUR or smooth-or Min.0.5-inch Structodek R-53. granule-surfaced modified bitumen over structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M High Density Fiberboard LRF-M EverGuard TPO/#1121, 82 5 concrete deck EnergyGuard Ultra Roof Insulation TPO 3-Square (Optional)Min.0.25-inch Existing smooth-orgranule-surfaced BUR orsmooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, DensDeck Prime or EverGuard TPO/#1121, R-54. granule-surfaced modified bitumen over structural EnergyGuard Ultra LRF-M SECUROCK Gypsum-Fiber LRF-M TPO 3-Square -75.0 concrete deck Roof Board (Optional when using base Existing smooth-or granule-surfaced BUR or smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO/#1121, R-55. granule-surfaced SBS or granule-surfaced APP modified EnergyGuard Polyiso Insulation,EnergyGuard LRF-M DensDeck Prime or LRF-M -225.0 bitumen overstructural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber TPO 3-Square Roof Board R-56. Existing smooth-or granule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A EverGuard TPO #1121, 450 granule-surfaced modified bitumen EnergyGuard Ultra TPO 3-Square Existing smooth-or granule-surfaced BUR;smooth-or R-57. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/#1121, _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation TPO 3-Square gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-58. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,6- (Optional)Additional layer LRF-XF,6- EverGuard TPO/#1121, -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-59. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,4- (Optional)Additional layer LRF-XF,4- EverGuard TPO/#1121, -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO 3-Square gravel,overstructural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers EverGuard TPO/#1121, R-60. granule-surfaced SBS or APP modified bitumen over EnergyGuard Ultra or EnergyGuard RH LRF-XF base insulation LRF-XF TPO 3-Square -180.0 structural concrete deck Existing smooth-surfaced modified bitumen overstruct. Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layer EverGuard TPO/#1121, R-61. LRF-XF LRF-XF concrete deck EnergyGuard Ultra of base insulation TPO 3-Square 222.5 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 128 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) R-62. Existing smooth-surface BUR over struct.concrete deck Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/#1121, -262.5 EnergyGuard Ultra of base insulation TPO 3-Square Existing granule-surface modified bitumen overstruct. Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/#1121, 0 -270 R-63. concrete deck EnergyGuard Ultra of base insulation TPO 3-Square . Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1.5-inch EnergyGuard RA or EnergyGuard Min.0.25-inch DensDeck or EverGuard TPO/#1121, R-64. granule-surfaced SBS or granule-surfaced APP modified RH LRF-XF DensDeck Prime LRF-XF TPO 3-Square -130.0 bitumen over structural concrete deck Existing smooth-surfaced modified bitumen over struct. (Optional)Min.2-inch EnergyGuard RA or Min.0.25-inch SECUROCK EverGuard TPO/#1121, R-65. concrete deck EnergyGuard RH LRF-XF Gypsum-Fiber Roof Board LRF-XF TPO 3-Square 222.5 R-66. Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF None N/A EverGuard TPO/#1121, _245.0 bitumen over struct.concrete deck Board TPO 3-Square Existing smooth-surface BUR or granule surface modified Min.2-inch EnergyGuard RA or EnergyGuard Min.0.25-inch SECUROCK EverGuard TPO/#1121, R-67. bitumen over struct.concrete deck RH LRF-XF Gypsum-Fiber Roof Board LRF-XF TPO 3-Square 247.5 Existing smooth-orgranule-surfaced BUR;smooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO #1121, R-68. granule-surfaced SB5 modified bitumen or granule- EnergyGuard Ultra 0B500 None N/A TPO 3-Square -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-69. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OB500 EverGuard TPO/#1121, _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation TPO 3-Square gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Additional layer EverGuard TPO/#1121, R-70. granule-surfaced SBS modified bitumen or granule- Min.1.5-inch EnergyGuard Ultra OB500 of base insulation OB500 TPO 3-Square -120.0 surfaced APP modified bitumen overstruct.concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-71. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation 0B500,6- (Optional)Additional layer OB500,6- EverGuard TPO/#1121, -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO 3-Square gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R 72 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation 0B500,4- (Optional)Additional layer OB500,4- EverGuard TPO/#1121, _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO 3-Square gravel,over structural concrete deck Min.0.5-inch EnergyGuard Existing smooth-or granule-surfaced BUR;smooth-or RH HD Polyiso Insulation, R-73. granule-surfaced SB5 modified bitumen or granule- (Optional)Min.0.5-inch EnergyGuard Polyiso 0B500 EnergyGuard HD Polyiso OB500 EverGuard TPO/#1121, 97 5 surfaced APP modified bitumen overstruct.concrete deck Insulation or min.1.5-inch EnergyGuard RH Insulation,EnergyGuard HD TPO 3-Square Plus Polyiso Insulation Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.5-inch Structodek EverGuard TPO/#1121, R-74. granule-surfaced SBS modified bitumen or granule- EnergyGuard Ultra 0B500 High Density Fiberboard OB500 TPO 3-Square 82.5 surfaced APP modified bitumen overstruct.concrete deck Roof Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 129 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.25-inch DensDeck EverGuard TPO/#1121, R-75. granule-surfaced SB5 modified bitumen or granule- Min.1.5-inchlnsulfoam OB500 prime OB500 TPO 3-Square 45.0 surfaced APP modified bitumen Min.0.25-inch DensDeck or Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.1.5-inch EnergyGuard RA, DensDeck Prime or EverGuard TPO/#1121, R-76. granule-surfaced SBS modified bitumen or granule- EnergyGuard RH,EnergyGuard RN,min.2-inch, OB500 SECUROCK Gypsum-Fiber OB500 TPO 3-Square -120.0 surfaced APP modified bitumen over struct.concrete deck min.2.0 pcf,Insulfoam EPS Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR;smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO/#1121, R-77. granule-surfaced SBS or APP modified bitumen over EnergyGuard Polyiso Insulation,EnergyGuard OB500 DensDeck Prime or OB500 Eve Eve 3-Square -225.0 structural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber TPO Roof Board EverGuard TPO/EverGuard WB382 Bonding Adhesive: R78 Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO WB181 -45.0 granule-surfaced modified bitumen EnergyGuard Ultra Existing smooth-or granule-surfaced BUR;smooth-or R 79 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/WB181 -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SBS modified bitumen or gravel-surfaced GAF 2-Part, (Optional)Additional layer GAF 2-Part, R-80. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation 6-inch o.c. of base insulation 6-inch o.c. EverGuard TPO/WB181 -157.5 gravel,overstructural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers R-81. granule-surfaced SBS or APP modified bitumen over EnergyGuard Ultra,EnergyGuard RH, GAF 2-Part base insulation GAF 2-Part EverGuard TPO/WB181 -180.0 structural concrete deck EnergyGuard RN Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SBS modified bitumen or gravel-surfaced GAF 2-Part, (Optional)Additional layer GAF 2-Part, R-82. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation 4-inch o.c. of base insulation 4-inch o.c. EverGuard TPO/WB181 -200.0 gravel,over structural concrete deck R-83. Existing smooth-surfaced modified bitumen over structural Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/WB181 -222.5 concrete deck EnergyGuard Ultra of base insulation R-84. Existing smooth-surface BUR over structural concrete deck Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/WB181 -245.0 EnergyGuard Ultra of base insulation R-85. Existing granule-surface modified bitumen overstructural Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/WB181 -270.0 concrete deck EnergyGuard Ultra of base insulation Min.0.25-inch Min.0.25- Existing smooth-or granule-surfaced BUR or smooth-or inch DensDeck Prime or R-86. granule-surfaced SB5 orgranule-surfaced APP modified Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part SECUROCK Gypsum-Fiber GAF 2-Part EverGuard TPO/WB181 -87.5 bitumen over structural concrete deck Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 130 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Min.0.25-inch Min.0.25- Existing smooth-or granule-surfaced BUR or smooth-or (Optional)Min.1.5-inch EnergyGuard RA, inch DensDeck Prime or R-87. granule-surfaced SBS or granule-surfaced APP modified EnergyGuard RH or EnergyGuard RN or Min. GAF 2-Part SECUROCK Gypsum-Fiber GAF 2-Part EverGuard TPO/WB181 -130.0 bitumen over structural concrete deck 1.5-inch thick,min.1.5 pcf Insulfoam EP$ Roof Board R 88 Existing smooth-or granule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO/WB181 -45.0 granule-surfaced modified bitumen EnergyGuard Ultra Existing smooth-or granule-surfaced BUR;smooth-or R 89 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard TPO/WB181 -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-90. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,6- (Optional)Additional layer LRF-M,6- EverGuard TPO/WB181 -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SBS modified bitumen or gravel-surfaced LRF-M,4- (Optional)Additional layer LRF-M,4- R-91. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. EverGuard TPO/WB181 -200.0 gravel,overstructural concrete deck Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, R-92. granule-surfaced modified bitumen over structural Insulation or min.Min.1.5-inch EnergyGuard LRF-M EnergyGuard HD Polyiso LRF-M EverGuard TPO/WB181 -75.0 concrete deck RH Insulation,EnergyGuard HD Plus Polyiso Insulation (Optional)Min.0.25-inch Existing smooth-or granule-surfaced BUR or smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, DensDeck Prime or R-93. granule-surfaced modified bitumen over structural EnergyGuard Ultra LRF-M SECUROCK Gypsum-Fiber LRF-M EverGuard TPO/WB181 -75.0 concrete deck Roof Board (Optional when using base Existing smooth-or granule-surfaced BUR or smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch R-94. granule-surfaced SB5 or granule-surfaced APP modified EnergyGuard Polyiso Insulation,EnergyGuard LRF-M DensDeck Prime or LRF-M EverGuard TPO/W13181 -225.0 bitumen over structural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber Roof Board R-95. Existing smooth-or granule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A EverGuard TPO WB181 -45.0 granule-surfaced modified bitumen EnergyGuard Ultra Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SBS modified bitumen or gravel-surfaced Min (Optional)Additional layer WB181 -110.0 LRF-XF EverGuard TPO R-96. BUR,brushed/spudded and vacuumed to remove loose .1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation / gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02819 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 131 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SB5 modified bitumen or gravel-surfaced LRF-XF,6- (Optional)Additional layer LRF-XF,6- R-97. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. EverGuard TPO/WB181 -157.5 gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers R-98. granule-surfaced SB5 or APP modified bitumen over EnergyGuard Ultra or EnergyGuard RH LRF-XF base insulation LRF-XF EverGuard TPO/WB181 -180.0 structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-99. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,4- (Optional)Additional layer LRF-XF,4- EverGuard TPO/WB181 -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch O.C. gravel,over structural concrete deck R-100. Existing smooth-surfaced modified bitumen over structural Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/WB181 -222.5 concrete deck EnergyGuard Ultra of base insulation R-101. Existing smooth-surface BUR over structural concrete deck Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/WB181 -245.0 EnergyGuard Ultra of base insulation R-102. Existing granule-surface modified bitumen overstructural Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/WB181 -270.0 concrete deck EnergyGuard Ultra of base insulation Min.0.25-inch Min.0.25- Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)Min.1.5-inch EnergyGuard RA or inch DensDeck Prime or R-103. granule-surfaced SB5 or granule-surfaced APP modified EnergyGuard RH LRF-XF SECUROCK Gypsum-Fiber LRF-XF EverGuard TPO/WB181 -130.0 bitumen over structural concrete deck Roof Board Existing smooth-orgranule-surfaced BUR;smooth-or Min.1-inch EnergyGuard Polyiso Insulation, R-104. granule-surfaced SB5 modified bitumen or granule- EnergyGuard Ultra OB500 None N/A EverGuard TPO/WB181 -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-105. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OB500 EverGuard TPO/WB181 -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or (Optional)Additional layer R-106. granule-surfaced SBS modified bitumen or granule- Min.1.5-inch EnergyGuard Ultra OB500 of base insulation OB500 EverGuard TPO/WB181 -120.0 surfaced APP modified bitumen over struct.concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-107. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnerGuard Poliso Insulation OB500,6- (Optional)Additional layer OB500,6- EverGuard TPO/WB181 -157.5 gy y BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch O.C. gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SBS modified bitumen or gravel-surfaced OB500,4- (Optional)Additional layer OB500,4- R-108. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. EverGuard TPO/WB181 -200.0 gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 132 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Min.0.5-inch EnergyGuard Existing smooth-or granule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, R-109. granule-surfaced SBS modified bitumen or granule- Insulation or min.1.5-inch EnergyGuard RH 0B500 EnergyGuard HD Polyiso OB500 EverGuard TPO/WB181 -97.5 surfaced APP modified bitumen over struct.concrete deck Insulation,EnergyGuard HD Plus Polyiso Insulation Existing smooth-or granule-surfaced BUR;smooth-or Min.0.25-inch DensDeck R-110. granule-surfaced SBS modified bitumen orgranule- Min.1.5-inch Insulfoam 0B500 OB500 EverGuard TPO/WB181 -45.0 surfaced APP modified bitumen Prime Existing smooth-or granule-surfaced BUR;smooth-or Min.1.5-inch EnergyGuard RA,EnergyGuard Min.0.25-inch DensDeck R-111. granule-surfaced SBS modified bitumen or granule- RH,EnergyGuard RN,min.2-inch,min.2.0 pcf, OB500 prime OB500 EverGuard TPO/WB181 -120.0 surfaced APP modified bitumen over struct.concrete deck Insulfoam EPS (Optional when using base Existing smooth-orgranule-surfaced BUR;smooth-or (Optional when using coverboard)Min.0.5-inch insluation)Min.0.25-inch R-112. granule-surfaced SBS or APP modified bitumen over EnergyGuard Polyiso Insulation,EnergyGuard OB500 DensDeck Prime or OB500 EverGuard TPO/WB181 -225.0 structural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber Roof Board EverGuard TPO in EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: R-113. Existing asphalt BUR or mineral surface cap sheet Min.1.5-inch EnergyGuard RA,EnergyGuard RH Hot Asphalt (Optional)Min.0.25-inch Hot asphalt EverGuard TPO/TPO 5- -45.0 or EnergyGuard RN DensDeck Prime Square,TPO 3-Square R-114. Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO/TPO 5- -45.0 granule-surfaced modified bitumen EnergyGuard Ultra Square,TPO 3-Square Existing smooth-or granule-surfaced BUR;smooth-or R-115. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/TPO 6- _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-116. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/TPO 6- _157.5 BUR,brushed/spudded and vacuumed to remove loose 6-inch o.c. of base insulation 6-inch o.c. Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers EverGuard TPO/TPO 6- R-117. granule-surfaced SBS or APP modified bitumen over EnergyGuard Ultra,EnergyGuard RH, GAF 2-Part base insulation GAF 2-Part Square,TPO 3-Square -180.0 structural concrete deck EnergyGuard RN Existing smooth-or granule-surfaced BUR;smooth-or R-118. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/TPO 6- _200.0 BUR,brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. Square,TPO 3-Square gravel,over structural concrete deck R-119. Existing smooth-surface modified bitumen over struct. Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/TPO 6- 222 5 concrete deck EnergyGuard Ultra of base insulation Square,TPO 3-Square Existing smooth-surface BUR or granule-surface modified Min.1.5-inch EnergyGuard Polyiso GAF 2-Part Insulation, (Optional)Additional layer EverGuard TPO/TPO 6- R-120. bitumen over struct.concrete deck EnergyGuard Ultra of base insulation GAF 2-Part Square,TPO 3-Square -245.0 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 133 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) R-121. Existing granule-surfaced modified bitumen over struct. Min.1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/TPO 6- _270.0 concrete deck EnergyGuard Ultra of base insulation Square,TPO 3-Square R-122. Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO/TPO 6- -45.0 granule-surfaced modified bitumen EnergyGuard Ultra Square,TPO 3-Square Existing smooth-or granule-surfaced BUR;smooth-or R-123. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard TPO/TPO 6- -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-124. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,6- (Optional)Additional layer LRF-M,6- EverGuard TPO/TPO 6- -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-125. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,4- (Optional)Additional layer LRF-M,4- EverGuard TPO/TPO 6- _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Square,TPO 3-Square gravel,overstructural concrete deck Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard TPO/TPO 6- R-126. granule-surfaced modified bitumen over structural Insulation or min.Min.1.5-inch EnergyGuard LRF-M EnergyGuard HD Polyiso LRF-M Square,TPO 3-Square 75.0 concrete deck RH Insulation,EnergyGuard HD Plus Polyiso Insulation Existing smooth-or granule-surfaced BUR or smooth-or Min.0.5-inch Structodek R-127. granule-surfaced modified bitumen over structural Min.0.5-inch EnergyGuard Polyiso Insulation, LRF-M High Density Fiberboard LRF-M EverGuard TPO/TPO 6- 82 5 concrete deck EnergyGuard Ultra Roof Insulation Square,TPO 3-Square Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.5-inch Structodek EverGuardTPO/TP06- R-128. granule-surfaced modified bitumen over structural EnergyGuard Ultra LRF-M High Density Fiberboard LRF-M Square,TPO 3-Square 82.5 concrete deck Roof Insulation (Optional)Min.0.25-inch Existing smooth-orgranule-surfaced BUR orsmooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, DensDeck Prime or EverGuard TPO/TPO 6- R-129. granule-surfaced modified bitumen over structural 75.0 EnergyGuard Ultra LRF-M SECUROCK Gypsum-Fiber LRF-M Square,TPO 3-Square concrete deck Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR or smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO/TPO 6- bitumen over structural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber R-130. granule-surfaced SBS orgranule-surfaced APP modified EnergyGuard Polyiso Insulation,EnergyGuard LRF-M DensDeck Prime or LRF-M -225.0 Square,TPO 3-Square Roof Board Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO/TPO 6- R-131. granule-surfaced modified bitumen tLRF-.F None N/A -45.0 g EnergyGuard Ultra Square,TPO 3-Square NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7t^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 134 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or R-132. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO 6- -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-133. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,6- (Optional)Additional layer LRF-XF,6- EverGuard TPO/TPO 6- -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers EverGuard TPO/TPO 6- R-134. granule-surfaced SB5 or APP modified bitumen over EnergyGuard Ultra or EnergyGuard RH LRF-XF base insulation LRF-XF Square,TPO 3-Square -180.0 structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-135. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,4- (Optional)Additional layer LRF-XF,4- EverGuard TPO/TPO 6- _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Square,TPO 3-Square gravel,over structural concrete deck R-136. Existing smooth-surface modified bitumen over struct. Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO 6- 222 5 concrete deck EnergyGuard Ultra of base insulation Square,TPO 3-Square Existing smooth-surface BUR or granule-surface modified Min.1.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layer EverGuard TPO/TPO 6- R-137. LRF-XF LRF-XF bitumen over struct.concrete deck EnergyGuard Ultra of base insulation Square,TPO 3-Square -245.0 R-138. Existing granule-surfaced modified bitumen over struct. Min.1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO 6- -270.0 concrete deck EnergyGuard Ultra of base insulation Square,TPO 3-Square Existing smooth-or granule-surfaced BUR;smooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO/TPO 6- R-139. granule-surfaced SBS modified bitumen or granule- EnergyGuard Ultra OB500 None N/A Square,TPO 3-Square 45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-140. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OBS00 EverGuard TPO/TPO 6- -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or (Optional)Additional layer EverGuard TPO/TPO 6- R-141. granule-surfaced SBS modified bitumen or granule- Min.1.5-inch EnergyGuard Ultra OB500 of base insulation OB500 Square,TPO 3-Square -120.0 surfaced APP modified bitumen over struct.concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-142. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,6- (Optional)Additional layer OB500,6- EverGuard TPO/TPO 6- _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Square,TPO 3-Square gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-143. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,4- (Optional)Additional layer OB500,4- EverGuard TPO/TPO 6- -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Square,TPO 3-Square gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 135 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard TPO/TPO 6- R-144. granule-surfaced SBS modified bitumen or granule- Insulation or min.Min.1.5-inch EnergyGuard OB500 EnergyGuard HD Polyiso OB500 Square,TPO 3-Square 97.5 surfaced APP modified bitumen overstruct.concrete deck RH Insulation,EnergyGuard HD Plus Polyiso Insulation Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.5-inch Structodek EverGuard TPO/TPO 5- R-145. granule-surfaced SBS modified bitumen or granule- EnergyGuard Ultra 0B500 High Density Fiberboard OB500 Square,TPO 3-Square 82.5 surfaced APP modified bitumen over struct.concrete deck Roof Insulation (Optional)Min.1.5-inch EnergyGuard RA, Existing smooth-or granule-surfaced BUR;smooth-or Min.0or SE ch DensDeck R-146. granule-surfaced SBS modified bitumen or granule- EnergyGuard RH or EnergyGuard RN,min.2- OB500 Prime or CUROCK 0B500 EverGuard TPO/TPO 6- -45.0 surfaced APP modified bitumen inch,min.2.0 pcf,Insulfoam EPS or min.1.5- Gypsum-Fiber Roof Board Square,TPO 3-Square inchlnsulfoam (Optional when using brae Existing smooth-orgranule-surfaced BUR;smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO/TPO 6- R-147. granule-surfaced SBS or APP modified bitumen over EnergyGuard Polyiso Insulation,EnergyGuard OB500 DensDeck Prime or OB500 Square,TPO 3-Square -225.0 structural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber Roof Board EverGuard TPO/EverGuard TPO Quick Spray: R-148. Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation GAF 2-Part None N/A EverGuard TPO/TPO QSA -45.0 granule-surfaced modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SBS modified bitumen or gravel-surfaced Min (Optional)Additional layer R-149. BUR,brushed/spudded and vacuumed to remove loose .1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part EverGuard TPO/TPO QSA -82.5 gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR or smooth-or Min.1.5-inch EnergyGuard RA,EnergyGuard RH Min.0.25-inch DensDeck R-150. granule-surfaced SBS or granule-surfaced APP modified or EnergyGuard RN or Min.1.5-inch thick,min. GAF 2-Part prime GAF 2-Part EverGuard TPO/TPO QSA -130.0 bitumen over structural concrete deck 1.5 pcf Insulfoam EPS Existing smooth-or granule-surfaced BUR or smooth-or Min.0.25-inch DensDeck R-151. granule-surfaced SBS orgranule-surfaced APP modified Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part prime GAF 2-Part EverGuard TPO/TPO QSA -87.5 bitumen over structural concrete deck R-152. Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard TPO/TPO QSA -45.0 granule-surfaced modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-153. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard TPO/TPO QSA -82.5 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR or smooth-or (Optional)Min.0.25-inch R-154. granule-surfaced modified bitumen over structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-M DensDeck Prime LRF-M EverGuard TPO/TPO QSA concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02819 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 136 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.25-inch DensDeck R-155. granule-surfaced SB5 or granule-surfaced APP modified Insulation,EnergyGuard Ultra or min.1.5-inch LRF-M LRF-M EverGuard TPO/TPO QSA -225.0 bitumen over structural concrete deck EnergyGuard RH Prime Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.25-inch SECUROCK R-156. granule-surfaced modified bitumen over structural Insulation or min.1.5-inch EnergyGuard RH LRF-M Gypsum-Fiber Roof Board LRF-M EverGuard TPO/TPO QSA -75.0 concrete deck Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso HD Polyiso In EnergyGuard R-157. granule-surfaced modified bitumen over structural Insulation or min.Min.1.5-inch EnergyGuard LRF-M HD Polyiso Insulation, LRF-M EverGuard TPO/TPO QSA -75.0 concrete deck RH EnergyGuard HD Plus Polyiso Insulation Existing smooth-or granule-surfaced BUR or smooth-or R-158. granule-surfaced modified bitumen Min.1-inch EnergyGuard Polyiso Insulation LRF-XF None N/A EverGuard TPO/TPO QSA -45.0 Existing smooth-or granule-surfaced BUR;smooth-or R-159. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO QSA -82.5 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR or smooth-or Min.1.5-inch EnergyGuard RA or EnergyGuard Min.0.25-inch DensDeck R-160. granule-surfaced SB5 or granule-surfaced APP modified RH LRF-XF prime LRF-XF EverGuard TPO/TPO QSA -130.0 bitumen over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-161. granule-surfaced SBS modified bitumen or granule- Min.1-inch EnergyGuard Polyiso Insulation OB500 None N/A EverGuard TPO/TPO QSA -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-162. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OBSOO EverGuard TPO/TPO QSA -82.5 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or Min.0.25-inch DensDeck R-163. granule-surfaced SBS modified bitumen or granule- Min.1.5-inchlnsulfoam OB500 Prime OBSoo EverGuard TPO/TPO QSA -45.0 surfaced APP modified bitumen Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.1.5-inch EnergyGuard RA, Min.0.25-inch DensDeck R-164. granule-surfaced SB5 modified bitumen or granule- EnergyGuard RH,EnergyGuard RN,min.2-inch, OB500 prime OB500 EverGuard TPO/TPO QSA -120.0 surfaced APP modified bitumen over struct.concrete deck min.2.0 pcf,Insulfoam EPS Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.25-inch DensDeck R-165. granule-surfaced SB5 or APP modified bitumen over Insulation,EnergyGuard Ultra or min.1.5-inch OB500 OB500 EverGuard TPO/TPO QSA -225.0 structural concrete deck EnergyGuard RH Prime Existing smooth-or granule-surfaced BUR;smooth-or R-166. granule-surfaced SBS modified bitumen or granule- (Optional)Min.0.5-inch EnergyGuard Polyiso OB500 Min.0.25-inch SECUROCK OB500 EverGuard TPO/TPO QSA -97.5 surfaced APP modified bitumen over structural concrete Insulation or min.1.5-inch EnergyGuard RH Gypsum-Fiber Roof Board deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7t^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 137 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso HD Polyiso Insulation, R-167. granule-surfaced SBS modified bitumen or granule- Insulation or min.1.5-inch EnergyGuard RH 0B500 EnergyGuard HD Plus OB500 EverGuard TPO/TPO QSA -97.5 surfaced APP modified bitumen over struct.concrete deck Polyiso Insulation EverGuard TPO/EverGuard TPO Quick Spray LV SO: R-168. Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation GAF 2-Part None N/A EverGuard TPO/TPO QSA 45 0 granule-surfaced modified bitumen LV50 Existing smooth-or granule-surfaced BUR;smooth-or R-169. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/TPO QSA _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation LV50 gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-170. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/TPO QSA _157.5 BUR,brushed/spudded and vacuumed to remove loose 5-inch o.c. of base insulation 6-inch o.c. LV50 gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Additional layers EverGuard TPO TPO QSA R-171. granule-surfaced SBS or APP modified bitumen over Min.0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part base insulation GAF 2-Part LV50 -180.0 structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-172. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/TPO QSA _200.0 BUR,brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. LV50 gravel,overstructural concrete deck R-173. Existing smooth-surface modified bitumen over struct. Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/TPO QSA 222 5 concrete deck of base insulation LV50 th-surface BUR or granule-surface modified Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EveGuard TPO/TPO QSA R-174. Existing smoo _245.0 bitumen overstruct.concrete deck of base insulation LV5r 0 R-175. Existing granule-surfaced modified bitumen overstruct. Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/TPO QSA -270.0 concrete deck of base insulation LV50 Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.25-inch Min.0.25- EverGuard TPO TPO QSA R-176. granule-surfaced SB5 or granule-surfaced APP modified Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part inch DensDeck Prime GAF 2-Part LV50 87.5 bitumen overstructural concrete deck Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.1.5-inch EnergyGuard RA, Min.0.25-inch Min.0.25- EverGuard TPO TPO QSA R-177. granule-surfaced SBS orgranule-surfaced APP modified EnergyGuard RH or EnergyGuard RN or Min. GAF 2-Part inch DensDeck Prime GAF 2-Part LV50 -130.0 bitumen overstructural concrete deck 1.5-inch thick,min.1.5 pcf Insulfoam EPS Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.25-inch SECUROCK EverGuard TPO TPO QSA R-178. granule-surfaced SBS or granule-surfaced APP modified Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part LV50 87.5 bitumen overstructural concrete deck Existing smooth-orgranule-surfaced BUR orsmooth-or One or more layers,min.1.5-inch thick,min. Min.0.25-inch SECUROCK EverGuard TPO/TPO QSA R-179. granule-surfaced SB5 or granule-surfaced APP modified 1.5 pcf Insulfoam EPS GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part LV50 -180.0 bitumen overstructural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02819 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 138 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) (Optional)Min.2-inch EnergyGuard RA, R-180. Existing smooth-surfaced modified bitumen over struct. EnergyGuard RH or EnergyGuard RN or min. GAF 2-Part Min.um-Finch Roof Board GAF 2-Part EverGuard TPO/TPO QSA 222 5 concrete deck Gypsum-Fiber Roof Board LV50 1.5-inch thick,min.2.0 pcf Insulfoam EPS Existing smooth-surface BUR or granule-surface modified One or more layers,min.1.5-inch thick,min. Min.0.25-inch SECUROCK EverGuard TPO/TPO QSA R-181. bitumen over struct.concrete deck 2.0 pcf Insulfoam EPS GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part LV50 -240.0 R-182. Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part None N/A EverGuard TPO/TPO QSA _245.0 bitumen over struct.concrete deck Board LV50 Existing smooth-surface BUR or granule surface modified Min.2-inch EnergyGuard RA,EnergyGuard RH Min.0.25-inch SECUROCK EverGuard TPO/TPO QSA R-183. bitumen over struct.concrete deck or EnergyGuard RN GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part LV50 -247.5 Existing smooth-or granule-surfaced BUR or smooth-or Min 1-inch EnerGuard Pol EverGuard TPO/TPO QSA R-184. granule-surfaced modified bitumen . gyyiso Insulation LRF-M None N/A LV50 -45.0 Existing smooth-or granule-surfaced BUR;smooth-or R-185. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard TPO/TPO QSA -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation LV50 gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-186. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,6- (Optional)Additional layer LRF-M,6- EverGuard TPO/TPO QSA _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base Insulation inch o.c. LV50 gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-187. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,4- (Optional)Additional layer LRF-M,4- EverGuard TPO/TPO QSA -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. LV50 gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.25-inch DensDeck EverGuard TPO/TPO QSA R-188. granule-surfaced modified bitumen over structural EnergyGuard Ultra LRF-M prime LRF-M LV50 75.0 concrete deck Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.25-inch DensDeck EverGuard TPO/TPO QSA R-189. granule-surfaced SBS or granule-surfaced APP modified Insulation,EnergyGuard Ultra or min.1.5-inch LRF-M prime LRF-M LV50 -202.5 bitumen over structural concrete deck EnergyGuard RH Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.0.25-inch EverGuard TPO TPO QSA R-190. granule-surfaced modified bitumen over structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-M SECUROCK Gypsum-Fiber LRF-M LV50 75.0 concrete deck Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR or smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO/TPO QSA R-191. granule-surfaced SBS or granule-surfaced APP modified EnergyGuard Polyiso Insulation LRF-M SECUROCK Gypsum-Fiber LRF-M LV50 -225.0 bitumen overstructural concrete deck Roof Board Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)0.5-inch EnergyGuard Polyiso Min.0yisoIn EnergyGuard R-192. granule-surfaced modified bitumen over structural Insulation or min.Min.1.5-inch EnergyGuard LRF-M En Polyiso Insulation, LRF-M EverGuard TPO/TPO QSA 75 0 concrete deck RH EnergyGuard HD Plus LV50 Polyiso Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 139 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) R-193. Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation LRF-XF None N/A EverGuard TPO TPO QSA -45.0 granule-surfaced modified bitumen LV50 Existing smooth-or granule-surfaced BUR;smooth-or R-194. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO QSA _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation LV50 gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-195. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,6- (Optional)Additional layer LRF-XF,6- EverGuard TPO/TPO QSA _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. LV50 gravel,overstructural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Additional layers EverGuard TPO TPO QSA R-196. granule-surfaced SBS or APP modified bitumen over Min.0.5-inch EnergyGuard Polyiso Insulation LRF-XF base insulation LRF-XF LV50 -180.0 structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-197. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,4- (Optional)Additional layer LRF-XF,4- EverGuard TPO/TPO QSA _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. LV50 gravel,over structural concrete deck R-198. Existing smooth-surface modified bitumen over struct. Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO QSA 222 5 concrete deck of base insulation LV50 R-199. Existing smooth-surface BUR or granule-surface modified Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO QSA -245.0 bitumen over struct.concrete deck of base insulation LV50 R-200. Existing granule-surfaced modified bitumen over struct. Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/TPO QSA -270.0 concrete deck of base insulation LV50 Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)Min.1.5-inch EnergyGuard RA or Min.0.25-inch DensDeck EverGuard TPO/TPO QSA R-201. granule-surfaced SB5 or granule-surfaced APP modified EnergyGuard RH LRF-XF prime LRF-XF LV50 -130.0 bitumen over structural concrete deck R 202 Existing smooth-surfaced modified bitumen over struct. (Optional)Min.2-inch EnergyGuard RA or LRF-XF Min.0.25-inch SECUROCK LRF-XF EverGuard TPO/TPO QSA 222 5 concrete deck EnergyGuard RH Gypsum-Fiber Roof Board LV50 R-203. Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF None N/A EverGuard TPO/TPO QSA -245.0 bitumen over struct.concrete deck Board LV50 Existing smooth-surface BUR or granule surface modified Min.2-inch EnergyGuard RA or EnergyGuard Min.0.25-inch SECUROCK EverGuard TPO/TPO QSA R-204. bitumen over struct.concrete deck RH LRF-XF Gypsum-Fiber Roof Board LRF-XF LV50 -247.5 Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO/TPO QSA R-205. granule-surfaced SBS modified bitumen or granule- Min.1-inch EnergyGuard Polyiso Insulation OB500 None N/A LV50 -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-206. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OB500 EverGuard TPO/TPO QSA -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation LV50 gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 140 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or R 207 granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,6- (Optional)Additional layer OB500,6- EverGuard TPO/TPO QSA -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. LV50 gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R 208 granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,4- (Optional)Additional layer OB500,4- EverGuard TPO/TPO QSA -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. LV50 gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or Min.0.25-inch DensDeck EverGuard TPO/TPO QSA R-209. granule-surfaced SB5 modified bitumen or granule- Min.1.5-inch Insulfoam OB500 Prime OB500 LV50 -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or Min.1.5-inch EnergyGuard RA,EnergyGuard Min.0.25-inch DensDeck EverGuard TPO/TPO QSA R-210. granule-surfaced SBS modified bitumen or granule- RH,EnergyGuard RN,min.2-inch,min.2.0 pcf, OB500 Prime 06500 LV50 -120.0 surfaced APP modified bitumen over struct.concrete deck Insulfoam EPS Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.25-inch DensDeck EverGuard TPO/TPO QSA R-211. granule-surfaced SBS or APP modified bitumen over Insulation,EnergyGuard Ultra or min.1.5-inch OB500 Prime OB500 LV50 -202.5 structural concrete deck EnergyGuard RH Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.1.5-inch EnergyGuard RA, Min.0.25-inch SECUROCK EverGuard TPO/TPO Q5A R-212. granule-surfaced SBS modified bitumen or granule- EnergyGuard RH,EnergyGuard RN,min.2-inch, OB500 Gypsum-Fiber Roof Board OB500 LV50 -120.0 surfaced APP modified bitumen over struct.concrete deck min.2.0 pcf,Insulfoam EPS Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.25-inch SECUROCK EverGuard TPO/TPO QSA R-213. granule-surfaced SBS or APP modified bitumen over Insulation,EnergyGuard Ultra or min.1.5-inch OB500 Gypsum-Fiber Roof Board OB500 LV50 -225.0 structural concrete deck EnergyGuard RH Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso HD Polyiso Insulation, EverGuard TPO/TPO QSA R-214. granule-surfaced SBS modified bitumen or granule- Insulation or min.1.5-inch EnergyGuard RH OB500 EnergyGuard HD Plus OB500 LV50 97.5 surfaced APP modified bitumen over struct.concrete deck Polyiso Insulation EverGuard TPO in FastLayn TPO Adhesive: R-215. Existing asphalt BUR or mineral surface cap sheet Min.1.5-inch EnergyGuard RA hot asphalt (Optional)Min.0.25-inch hot asphalt EverGuard TPO/FastLayn -45.0 DensDeck Prime TPO Adhesive R-216. Existing smooth-or granule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation GAF 2-Part None N/A EverGuard TPO/FastLayn -45.0 granule-surfaced modified bitumen TPO Adhesive Existing smooth-or granule-surfaced BUR;smooth-or R-217. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/FastLayn -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation TPO Adhesive gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SBS modified bitumen or gravel-surfaced GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/FastLayn R-218. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation 6-inch o.c. of base insulation 6-inch o.c. TPO Adhesive -157.5 gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 141 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or granule surfaced SB5 modified bitumen or gravel-surfaced GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO/FastLayn R-219. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation 4-inch o.c. of base insulation 4-inch o.c. TPO Adhesive -200.0 gravel,overstructural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Additional layers EverGuard TPO/FastLayn R-220. granule-surfaced SB5 or APP modified bitumen over Min.0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part base insulation GAF 2-Part TPO Adhesive -180.0 structural concrete deck R-221. Existing smooth-surfaced modified bitumen over structural Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/FastLayn 222 5 concrete deck of base insulation TPO Adhesive R-222. Existing smooth-surface BUR over structural concrete deck Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/FastLayn -262.5 of base insulation TPO Adhesive R-223. Existing granule-surface modified bitumen over structural Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO/FastLayn -270.0 concrete deck of base insulation TPO Adhesive Existing smooth-orgranule-surfaced BUR or smooth-or Min.1.5-inch EnergyGuard RA,EnergyGuard RH Min.0.25-inch DensDeck EverGuard TPO/FastLayn R-224. granule-surfaced SBS or granule-surfaced APP modified or EnergyGuard RN or Min.1.5-inch thick,min. GAF 2-Part prime GAF 2-Part TPO Adhesive -130.0 bitumen overstructural concrete deck 1.5 pcf Insulfoam EPS Existing smooth-orgranule-surfaced BUR or smooth-or Min.0.25-inch DensDeck EverGuard TPO/FastLayn R-225. granule-surfaced SBS or granule-surfaced APP modified Min.1.5-inch thick,min.1.25 pcf Insulfoam EPS GAF 2-Part Prime or SECUROCK GAF 2-Part TPO Adhesive 87.5 bitumen overstructural concrete deck Gypsum-Fiber Roof Board Existing smooth-orgranule-surfaced BUR orsmooth-or One or more layers,min.1.5-inch thick,min. Min.0.25-inch SECUROCK EverGuard TPO/FastLayn R-226. granule-surfaced SBS orgranule-surfaced APP modified 1.5 pcf Insulfoam EPS GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO Adhesive -180.0 bitumen overstructural concrete deck (Optional)Min.2-inch EnergyGuard RA, R 227 Existing smooth-surfaced modified bitumen over structural EnergyGuard RH or EnergyGuard RN or min. GAF 2-Part Min.0.25-inch SECUROCK GAF 2-Part EverGuard TPO/FastLayn 222 5 concrete deck 1.5-inch thick,min.2.0 pcf Insulfoam EPS Gypsum-Fiber Roof Board TPO Adhesive Existing smooth-surface BUR or granule-surface modified One or more layers,min.1.5-inch thick,min. Min.0.25-inch SECUROCK EverGuard TPO/FastLayn R-228. GA bitumen overstructural concrete deck 2.0 pcf Insulfoam EPS F 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO Adhesive -240.0 R 229 Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof GAF 2-Part None N/A EverGuard TPO/FastLayn -245.0 bitumen overstructural concrete deck Board TPO Adhesive Existing smooth-surface BUR or granule surface modified Min.2-inch EnergyGuard RA,EnergyGuard RH Min.0.25-inch SECUROCK EverGuard TPO/FastLayn R-230. bitumen overstructural concrete deck or EnergyGuard RN GAF 2-Part Gypsum-Fiber Roof Board GAF 2-Part TPO Adhesive -247.5 R-231. Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard TPO FastLayn -45.0 granule-surfaced modified bitumen TPO Adhesive Existing smooth-or granule-surfaced BUR;smooth-or R-232. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard TPO/FastLayn _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation TPO Adhesive gravel,over structural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 142 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or R-233. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,6- (Optional)Additional layer LRF-M,6- EverGuard TPO/FastLayn _157.5 BUR,brushed/spudded and vacuumed to remove loose inch O.C. of base insulation inch o.c. TPO Adhesive gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-234. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,4- (Optional)Additional layer LRF-M,4- EverGuard TPO/FastLayn -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO Adhesive gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.5-inch EnergyGuard EverGuard TPO/FastLayn R-235. granule-surfaced modified bitumen over structural Insulation or min.1.5-inch EnergyGuard RH LRF-M HD Polyiso Insulation LRF-M TPO Adhesive -75.0 concrete deck (Optional)Min.0.25-inch Existing smooth-orgranule-surfaced BUR or smooth-or DensDeck Prime or EverGuard TPO/FastLayn R-236. granule-surfaced modified bitumen over structural Min.0.5-inch EnergyGuard Polyiso Insulation LRF-M SECUROCK Gypsum-Fiber LRF-M TPO Adhesive -75.0 concrete deck Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR or smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO/FastLayn R-237. granule-surfaced SB5 or granule-surfaced APP modified EnergyGuard Polyiso Insulation LRF-M DensDeck Prime or LRF-M TPO Adhesive -225.0 bitumen over structural concrete deck SECUROCK Gypsum-Fiber Roof Board R-238. Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation LRF-XF None N/A EverGuard TPO/FastLayn 45 0 granule-surfaced modified bitumen TPO Adhesive Existing smooth-or granule-surfaced BUR;smooth-or R-239. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard ve /FastLayn _110.0 BUR,brushed/spudded and vacuumed to remove loose (O base insulation TPO Adhesive gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-240. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,6- (Optional)Additional layer LRF-XF,6- EverGuard TPO/FastLayn _157.5 BUR,brushed/spudded and vacuumed to remove loose inch O.C. of base insulation inch o.c. TPO Adhesive gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-241. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,4- (Optional)Additional layer LRF-XF,4- EverGuard TPO/FastLayn _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO Adhesive gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Additional layers EverGuard TPO/FastLayn R-242. granule-surfaced SBS or APP modified bitumen over Min.0.5-inch EnergyGuard Polyiso Insulation LRF-XF base insulation LRF-XF TPO Adhesive -180.0 structural concrete deck R-243. Existing smooth-surfaced modified bitumen over structural Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/FastLayn 222 5 concrete deck of base insulation TPO Adhesive R-244. Existing smooth-surface BUR over structural concrete deck Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/FastLayn -262.5 of base insulation TPO Adhesive NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization H32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 143 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) R-245. Existing granule-surface modified bitumen over structural Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO/FastLayn -270.0 concrete deck of base insulation TPO Adhesive Existing smooth-orgranule-surfaced BUR or smooth-or Min.1.5-inch EnergyGuard RA or EnergyGuard Min.0.25-inch DensDeck EverGuard TPO/FastLayn R-246. granule-surfaced SBS or granule-surfaced APP modified RH LRF-XF prime LRF-XF TPO Adhesive -130.0 bitumen over structural concrete deck Existing smooth-surfaced modified bitumen over structural (Optional)Min.2-inch EnergyGuard RA or Min.0.25-inch SECUROCK EverGuard TPO/FastLayn R-247. concrete deck EnergyGuard RH LRF-XF Gypsum-Fiber Roof Board LRF-XF TPO Adhesive 222.5 R 248 Existing smooth-surface BUR or granule-surface modified Min.0.25-inch SECUROCK Gypsum-Fiber Roof LRF-XF None N/A EverGuard TPO/FastLayn _245.0 bitumen over structural concrete deck Board TPO Adhesive Existing smooth-surface BUR or granule surface modified Min.2-inch EnergyGuard RA or EnergyGuard Min.0.25-inch SECUROCK EverGuard TPO/FastLayn R-249. bitumen over structural concrete deck RH LRF-XF Gypsum-Fiber Roof Board LRF-XF TPO Adhesive -247.5 Existing smooth-orgranule-surfaced BUR;smooth-or EverGuard TPO/FastLayn R-250. granule-surfaced SBS modified bitumen or granule- Min.1-inch EnergyGuard Polyiso Insulation OB500 None N/A TPO Adhesive -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-251. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OB500 EverGuard TPO/FastLayn _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation TPO Adhesive gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-252. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,6- (Optional)Additional layer OB500,6- EverGuard TPO/FastLayn _157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO Adhesive gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-253. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,4- (Optional)Additional layer OB500,4- EverGuard TPO/FastLayn _200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO Adhesive gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or granule-surfaced SBS modified bitumen or granule- (Optional)Min.0.5-inch EnergyGuard Polyiso Min.0.5-inch EnergyGuard EverGuard TPO/FastLayn R-254. surfaced APP modified bitumen over structural concrete Insulation or min.1.5-inch EnergyGuard RH OB500 HD Polyiso Insulation OB500 TPO Adhesive 97.5 deck Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.25-inch DensDeck EverGuard TPO/FastLayn R-255. granule-surfaced SBS modified bitumen or granule- Min.1.5-inch,Insulfoam EPS OB500 Prime OB500 TPO Adhesive 45.0 surfaced APP modified bitumen Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.1.5-inch EnergyGuard RA, Min.0.25-inch DensDeck granule-surfaced SBS modified bitumen or granule- EnergyGuard RH,EnergyGuard RN,min.2-inch, EverGuard TPO/FastLayn R-256. surfaced APP modified bitumen over structural concrete min.2.0 pcf,Insulfoam EPS or min.1-inch 06500 Prime or SECUROCK OB500 TPO Adhesive -120.0 deck Foamular 250 Gypsum-Fiber Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR;smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO/FastLayn R-257. granule-surfaced SBS or APP modified bitumen over EnergyGuard Polyiso Insulation OB500 DensDeck Prime or OB500 TPO Adhesive -225.0 nergyuar oysonsuaon structural concrete deck SECUROCK Gypsum-Fiber Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 144 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF y Base Insulation Layer Top Insulation Layer System Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) ;p� (Notes 6,7,8) (Notes 6,7,8) EverGuard TPO Fleece-Back Membrane in EverGuard WB381 Bonding Adhesive: R-258. Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO Fleece-Back -45.0 granule-surfaced modified bitumen EnergyGuard Ultra Membrane/WB181 Existing smooth-or granule-surfaced BUR;smooth-or R-259. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part EverGuard TPO Fleece-Back -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Membrane/WB181 gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-260. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO Fleece-Back _157.5 BUR,brushed/spudded and vacuumed to remove loose 6-inch o.c. of base insulation 6-inch o.c. Membrane/WB181 gravel,overstructural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers EverGuard TPO Fleece-Back R-261. granule-surfaced SB5 or APP modified bitumen over EnergyGuard Ultra,EnergyGuard RH, GAF 2-Part GAF 2-Part -180.0 base insulation Membrane/WB181 structural concrete deck EnergyGuard RN Existing smooth-or granule-surfaced BUR;smooth-or R-262. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, EverGuard TPO Fleece-Back _200.0 BUR,brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. Membrane/WB181 gravel,overstructural concrete deck R-263. Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO Fleece-Back 450 granule-surfaced modified bitumen EnergyGuard Ultra Membrane/WB181 Existing smooth-orgranule-surfaced BUR orsmooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back R-264. granule-surfaced modified bitumen over structural EnergyGuard Ultra LRF-M None N/A Membrane/W6181 -75.0 concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-265. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional)Additional layer LRF-M EverGuard TPO Fleece-Back -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Membrane/WB181 gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-266. granule surfaced SB5 modified bitumen orgravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,6- (Optional)Additional layer LRF-M,6- EverGuard TPO Fleece-Back -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane/WB181 gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R-267. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M,4- (Optional)Additional layer LRF-M,4- EverGuard TPO Fleece-Back -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane/WB181 gravel,over structural concrete deck Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard TPO Fleece-Back R-268. granule-surfaced modified bitumen over structural Insulation or min.Min.1.5-inch EnergyGuard LRF-M EnergyGuard HD Polyiso LRF-M Membrane/WB181 75.0 concrete deck RH Insulation,EnergyGuard HD Plus Polyiso Insulation NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02819 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 145 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) (Optional when using base Existing smooth-orgranule-surfaced BUR or smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO Fleece-Back R-269. granule-surfaced SBS or granule-surfaced APP modified EnergyGuard Polyiso Insulation,EnergyGuard LRF-M DensDeck Prime or LRF-M -225.0 bitumen overstructural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber Membrane/WB181 Roof Board R270 Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A EverGuard TPO Fleece-Back 450 granule-surfaced modified bitumen EnergyGuard Ultra Membrane/WB181 Existing smooth-or granule-surfaced BUR;smooth-or R-271. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF EverGuard TPO Fleece-Back _110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Membrane/WB181 gravel,over structural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R 272 . . EnergyGuard y granule surfaced SBS modified bitumen or gravel-surfaced Min 15-inch EnerGuard Polyiso Insulation LRF-XF,6- (Optional)Additional layer LRF-XF,6- EverGuard TPO Fleece-Back _ BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane/WB181 157.5 gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers EverGuard TPO Fleece-Back R-273. granule-surfaced SBS or APP modified bitumen over LRF-XF LRF-XF -180.0 structural concrete deck EnergyGuard Ultra or EnergyGuard RH base insulation Membrane/WB181 Existing smooth-or granule-surfaced BUR;smooth-or R-274. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF,4- (Optional)Additional layer LRF-XF,4- EverGuard TPO Fleece-Back -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane/WB181 gravel,over structural concrete deck Existing smooth-orgranule-surfaced BUR;smooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back R-275. granule-surfaced SBS modified bitumen or granule- EnergyGuard Ultra OB500 None OB500 Membrane/WB181 -45.0 surfaced APP modified bitumen Existing smooth-or granule-surfaced BUR;smooth-or R-276. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OB500 EverGuard TPO Fleece-Back -110.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation Membrane/WB181 gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R 277 granule-surfaced SBS modified bitumen or granule- Min.1.5-inch EnergyGuard RA,EnergyGuard OB500 (Optional)Additional layers OB500 EverGuard TPO Fleece-Back -120.0 surfaced APP modified bitumen overstructural concrete RH,EnergyGuard RN base insulation Membrane/WB181 deck Existing smooth-or granule-surfaced BUR;smooth-or R 278 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,6- (Optional)Additional layer OB500,6- EverGuard TPO Fleece-Back -157.5 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane/WB181 gravel,overstructural concrete deck Existing smooth-or granule-surfaced BUR;smooth-or R 279 granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500,4- (Optional)Additional layer OB500,4- EverGuard TPO Fleece-Back -200.0 BUR,brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane/WB181 gravel,overstructural concrete deck NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7u^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMD ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 146 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Min.0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, R-280. granule-surfaced SBS modified bitumen or granule- Insulation or min.Min.1.5-inch EnergyGuard OB500 EnergyGuard HD Polyiso 06500 EverGuard TPO Fleece-Back 97 5 surfaced APP modified bitumen over structural concrete RH Insulation,EnergyGuard HD Membrane/WB181 deck Plus Polyiso Insulation Existing smooth-or granule-surfaced BUR;smooth-or Min.0.25-inch DensDeck R-281. granule-surfaced SB5 modified bitumen or granule- (Optional)Min.1.5-inch EnergyGuard RA, OB500 Prime or SECUROCK 0B500 EverGuard TPO Fleece-Back _120.0 surfaced APP modified bitumen overstructural concrete EnergyGuard RH,EnergyGuard RN Membrane/WB181 deck Gypsum-Fiber Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR;smooth-or (Optional when using coverboard)Min.0.5-inch insulation)Min.0.25-inch EverGuard TPO Fleece-Back R-282. granule-surfaced SB5 or APP modified bitumen over EnergyGuard Polyiso Insulation,EnergyGuard OB500 DensDeck Prime or OBS00 Membrane/W6181 -225.0 structural concrete deck Ultra or min.1.5-inch EnergyGuard RH SECUROCK Gypsum-Fiber Roof Board EverGuard TPO Fleece-Back Membrane in LRF Adhesive M or LRF Adhesive O: Existing smooth-orgranule-surfaced BUR or or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back R-283. granule-surfaced modified bitumen EnergyGuard Ultra GAF 2-Part None N/A Membrane/LRF- or LRF- -45.0 0,12-inch o.c. Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back R 284 granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional)Additional layer GAF 2-Part Membrane/LRF-M or LRF- -60.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck O,12-inch o.c. Optional additional layers Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece-Back R-285. granule-surfaced SB5 modified bitumen or granule- Insulation,EnergyGuard Ultra,EnergyGuard RH, GAF 2-Part min.0.25-inch DensDeck GAF 2-Part Membrane/LRF-M or LRF- -180.0 surfaced APP modified bitumen overstructural concrete deck EnergyGuard RN Prime or SECUROCK 0,4-inch o.c. Gypsum-Fiber Roof Board Existing smooth-orgranule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back R-286. granule-surfaced modified bitumen EnergyGuard Ultra LRF-M None N/A Membrane/LRF-M or LRF- -45.0 O,12-inch o.c. Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.1-inch EnergyGuard RA, Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back R-287. granule-surfaced modified bitumen EnergyGuard RH,EnergyGuard RN LRF-M RA,EnergyGuard RN LRF-M Membrane/LRF-M or LRF- -45.0 O,12-inch o.c. Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.1-inch EnergyGuard RA, Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back R-288. granule-surfaced modified bitumen EnergyGuard RH,EnergyGuard RN LRF-M RH LRF-M Membrane/LRF-O,12-inch -45.0 O.C. Existing smooth-orgranule-surfaced BUR orsmooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back R-289. granule-surfaced modified bitumen over struct.concrete EnerGuard Ultra LRF-M None N/A Membrane/LRF-M or LRF- -60.0 gy deck O,12-inch o.c. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 147 of 156 NNEMO etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SB5 modified bitumen or gravel-surfaced (Optional)Additional layer R-290. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M Membrane/LRF-M or LRF- -60.0 gravel,overstructural concrete deck 0,12-inch o.c. Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.1-inch EnergyGuard RA or Min.1.75-inch ACFoam EverGuard TPO Fleece-Back R-291. granule-surfaced modified bitumen ACFoam II LRF-M Composite/GB LRF-M Membrane/LRF-M,12-inch -37.5 O.C. (Optional)Min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR or smooth-or Insulation,EnergyGuard Ultra or min.1-inch Min.0.25-inch DensDeck R-292. granule-surfaced modified bitumen EnergyGuard RA,EnergyGuard RH, LRF-M Prime LRF-M Membrane/LRF-M,12-inch -37.5 EnergyGuard RN O.C. (Optional)Min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back R-293. Existing smooth-orgranule-surfaced BUR orsmooth-or Insulation,EnergyGuard Ultra or min.1-inch LRF-M Min.0.25-inch DensDeck LRF-M Membrane/LRF-0,12-inch -45.0 granule-surfaced modified bitumen EnergyGuard RA,EnergyGuard RH, Prime EnergyGuard RN O.C. (Optional)Min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR orsmooth-or Insulation,EnergyGuard Ultra or min.1-inch Min.0.25-inch SECUROCK R-294. granule-surfaced modified bitumen EnergyGuard RA,EnergyGuard RH, LRF-M Gypsum-Fiber Roof Board LRF-M Membrane/LRF-M or LRF- -45.0 0,12-inch o.c. EnergyGuard RN Min.0.25-inch Temple EverGuard TPO Fleece-Back Existing smooth-orgranule-surtacedBUR or smooth-or (Optional)Min.1-inch EnergyGuard RA,R-295. granule-surfaced modified bitumen EnergyGuard RH,EnergyGuard RN LRF-M Green Glass Primed Roof LRF-M Membrane/LRF-M or LRF- -37.5 Board 0,12-inch o.c. Optional additional layers Existing smooth-orgranule-surfaced BUR or smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece-Back R-296. granule-surfaced modified bitumen over structural Insulation,EnergyGuard Ultra,EnergyGuard RH, LRF-M min.0.25-inch DensDeck LRF-M Membrane/LRF-M or LRF- -180.0 concrete deck EnergyGuard RN Prime or SECUROCK 0,4-inch o.c. Gypsum-Fiber Roof Board Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back R-297. granule-surfaced modified bitumen EnergyGuard Ultra LRF-XF None N/A Membrane/LRF- or LRF- -45.0 0,12-inch o.c. Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back R-298. granule surfaced SB5 modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional)Additional layer LRF-XF Membrane/LRF-M or LRF- -60.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation 0,12-inch o.c. gravel,overstructural concrete deck Optional additional layers Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece-Back R 299 granule-surfaced SB5 modified bitumen or granule- Insulation,EnergyGuard Ultra or EnergyGuard LRF-XF min.0.25-inch DensDeck LRF-XF Membrane/LRF-M or LRF- -180.0 surfaced APP modified bitumen over structural concrete deck RH Prime or SECUROCK 0,4-inch o.c. Gypsum-Fiber Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 148 of 156 NNEMO etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-orgranule-surfaced BUR;smooth-or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece-Back R-300. granule-surfaced SB5 modified bitumen or granule- EnergyGuard Ultra OB500 None N/A Membrane/LRF-M or LRF- -45.0 nergyuar ra surfaced APP modified bitumen 0,12-inch o.c. Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.1-inch EnergyGuard RA, Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back R-301. granule-surfaced SBS modified bitumen or granule- EnergyGuard 1 EnergyGuard a ,OB500 RA EnergyGuard RN OB500 Membrane/LRF-M or LRF- -45.0 gy surfaced APP modified bitumen O,12-inch o.c. .1-inch EnergyGuard RA, Min.1.5-inch EnergyGuard EverGuard TPO Fleece-Back R-302. granule-surfaced SBS modified bitumen or granule- EnergyGuard RH,EnergyGuard RN 06500 RH OB500 Membrane/LRF-O,12-inch -45.0 Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min surfaced APP modified bitumen o.c. Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back R-303. granule-surfaced SBS modified bitumen or granule- Min.0.5-inch EnergyGuard Polyiso Insulation, OB500 None N/A Membrane/LRF-M or LRF- -60.0 surfaced APP modified bitumen overstructural concrete EnergyGuard Ultra O,12-inch o.[. deck Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back R-304. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional)Additional layer OB500 Membrane/LRF-M or LRF- -60.0 BUR,brushed/spudded and vacuumed to remove loose of base insulation gravel,over structural concrete deck O,12-inch o.c. Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.1-inch EnergyGuard RA Or Min.1.75-inch ACFoam EverGuard TPO Fleece-Back R-305. granule-surfaced SBS modified bitumen or granule- ACFoam 11 OB500 Composite/GB OB500 Membrane/LRF-M,12-inch -37.5 surfaced APP modified bitumen O.C. Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back Insulation,EnergyGuard Ultra or min.1-inch Min.0.25-inch DensDeck R-306. granule-surfaced SBS modified bitumen or granule- EnergyGuard RA EnergyGuard RH OB500 Prime OB500 Membrane/LRF-M,12-inch -37.5 , , surfaced APP modified bitumen O.C. EnergyGuard RN Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece-Back R-307. granule-surfaced SBS modified bitumen or granule- Insulation,EnergyGuard Ultra or min.1-inch OB500 Min.0.25-inch DensDeck OB500 Membrane/LRF-0,12-inch -45.0 surfaced APP modified bitumen EnergyGuard RA,EnergyGuard RH, Prime EnergyGuard RN O.C. Existing smooth-orgranule-surfaced (Optional)Min.0.5-inch EnergyGuard Polyisoaced BUR;smooth-or EverGuard TPO Fleece-Back Insulation,EnergyGuard Ultra or min.1-inch Min.0.25-inch SECUROCK R-308. granule-surfaced SBS modified bitumen or granule- EnergyGuard RA EnergyGuard RH OB500 Gypsum-Fiber Roof Board OB500 Membrane/LRF-M or LRF- -45.0 , , surfaced APP modified bitumen O,12-Inch o.c. EnergyGuard RN Existing smooth-orgranule-surtaced BUR;smooth-or (Optional)Min.1-inch EnergyGuard RA, Min.0.25-inch Temple EverGuard TPO Fleece-Back R-309. granule-surfaced SBS modified bitumen or granule- EnergyGuard RH EnergyGuard RN OB500 Green Glass Primed Roof OB500 Membrane/LRF-M or LRF- -37.5 gy , gy surfaced APP modified bitumen Board 0,12-inch o.c. Optional additional layers Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece-Back R-310. granule-surfaced SBS modified bitumen or granule- Insulation,EnergyGuard Ultra,EnergyGuard RH, OB500 min.0.25-inch DensDeck OB500 Membrane/LRF-M or LRF- -180.0 surfaced APP modified bitumen overstructural concrete deck EnergyGuard RN Prime or SECUROCK 0,4-inch o.c. Gypsum-Fiber Roof Board NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NENIO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 149 of 156 NNEMO etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF y Base Insulation Layer Top Insulation Layer System Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) ;p� (Notes 6,7,8) (Notes 6,7,8) EverGuard TPO Fleece-Back Membrane in Spatter Applications: EverGuard TPO Fleece-Back Existing smooth-or granule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, Membrane/GAF 2-Part R-311. granule-surfaced modified bitumen EnergyGuard Ultra GAF 2-Part None N/A (spatter),LRF-XF(spatter)or -45.0 OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced Min (Optional)Additional layer Membrane/GAF 2-Part -110.0 R-312. BUR,brushed/spudded and vacuumed to remove loose .1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part (spatter),LRF-XF(spatter)or gravel,overstructural concrete deck OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back R-313. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, Membrane/GAF 2-Part _157.5 BUR,brushed/spudded and vacuumed to remove loose 6-inch o.c. of base insulation 6-inch o.c. (spatter),LRF-XF(spatter)or gravel,over structural concrete deck OB500(spatter) EverGuard Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, / Fleece-Back G (Optional)Additional layers Membrane/GAF 2-Part R-314. granule-surfaced 5B5 or APP modified bitumen over EnergyGuard Ultra,EnergyGuard RA, GAF 2-Part base insulation GAF 2-Part (spatter),LRF-XF(spatter)or -180.0 structural concrete deck EnergyGuard RH,EnergyGuard RN OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back R-315. granule surfaced SBS modified bitumen or gravel-surfaced Min.1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional)Additional layer GAF 2-Part, Membrane/GAF 2-Part -200.0 BUR,brushed/spudded and vacuumed to remove loose 4-inch O.C. of base insulation 4-inch o.c. (spatter),LRF-XF(spatter)or gravel,overstructural concrete deck OB500(spatter) Optional additional layers EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by Membrane/GAF 2-Part R-316. granule-surfaced SBS or APP modified bitumen over Insulation,EnergyGuard Ultra,EnergyGuard RA, GAF 2-Part min.0.25-inch DensDeck GAF 2-Part (spatter),LRF-XF(spatter)or -180.0 structural concrete deck EnergyGuard RH,EnergyGuard RN Prime or SECUROCK Gypsum-Fiber Roof Board OB500(spatter) EverGuard TPO Fleece-Back Existing smooth-or granule-surfaced BUR or smooth-or Min.1-inch EnergyGuard Polyiso Insulation, Membrane/GAF 2-Part R-317. granule-surfaced modified bitumen EnergyGuard Ultra LRF-M None N/A (spatter),LRF-XF(spatter)or 45.0 OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced Min (Optional)Additional layer LRF-M Membrane/GAF 2-Part -110.0 R-318. BUR,brushed/spudded and vacuumed to remove loose .1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation (spatter),LRF-XF(spatter)or gravel,overstructural concrete deck OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced LRF-M,6- (Optional)Additional layer LRF-M,6- Membrane/GAF 2-Part R-319. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter),LRF-XF(spatter)or -157.5 gravel,over structural concrete deck I OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 150 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced LRF-M,4- (Optional)Additional layer LRF-M,4- Membrane/GAF 2-Part R-320. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation -200.0 inch o.c. of base insulation inch o.c. (spatter),LRF-XF(spatter)or gravel,over structural concrete deck OB500(spatter) Optional additional layers EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by Membrane/GAF 2-Part R-321. granule-surfaced modified bitumen over structural Insulation,EnergyGuard Ultra,EnergyGuard RH, LRF-M min.0.25-inch DensDeck LRF-M -180.0 (spatter),LRF-XF(spatter)or concrete deck EnergyGuard RN Prime or SECUROCK Gypsum-Fiber Roof Board OB500(spatter) EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR orsmooth-or Min.1-inch EnergyGuard Polyiso Insulation, Membrane/GAF 2-Part R-322. granule-surfaced modified bitumen EnergyGuard Ultra LRF-XF None N/A (spatter),LRF-XF(spatter)or 45.0 OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced (Optional)Additional layer Membrane/GAF 2-Part R-323. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF -110.0 (spatter),LRF-XF(spatter)or gravel,overstructural concrete deck OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen orgravel-surfaced LRF-XF,6- (Optional)Additional layer LRF-XF,6- Membrane/GAF 2-Part R-324. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter),LRF-XF(spatter)or -157.5 gravel,over structural concrete deck OB500(spatter) EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR;smooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, (Optional)Additional layers Membrane/GAF 2-Part R-325. granule-surfaced SBS or APP modified bitumen over EnergyGuard Ultra,EnergyGuard RA or LRF-XF base insulation LRF-XF (spatter),LRF-XF(spatter)or -180.0 structural concrete deck EnergyGuard RH OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced LRF-XF,4- (Optional)Additional layer LRF-XF,4- Membrane/GAF 2-Part R-326. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation -200.0 inch o.c. of base insulation inch o.c. (spatter),LRF-XF(spatter)or gravel,over structural concrete deck OB500(spatter) Optional additional layers EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by Membrane/GAF 2-Part R-327. granule-surfaced SBS or APP modified bitumen over Insulation,EnergyGuard Ultra,EnergyGuard RA LRF-XF min.0.25-inch DensDeck LRF-XF (spatter),LRF-XF(spatter)or -180.0 structural concrete deck or EnergyGuard RH Prime or SECUROCK Gypsum-Fiber Roof Board OB500(spatter) EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR;smooth-or Min.1-inch EnergyGuard Polyiso Insulation, Membrane/GAF 2-Part R-328. granule-surfaced SBS modified bitumen or granule- EnergyGuard Ultra 0B500 None N/A (spatter),LRF-XF(spatter)or -45.0 surfaced APP modified bitumen OB500(spatter) NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization H32455 7t^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 151 of 156 NNEMO I etc. TABLE 7A:RECOVER APPLICATIONS SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Sy No. oem Substrate(Notes 1&12) Type Attach Type Attach Roof Cover(Note 15) Psfl (Notes 6,7,8) (Notes 6,7,8) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced Min (Optional)Additional layer OB500 Membrane/GAF 2-Part -110.0 R-329. BUR,brushed/spudded and vacuumed to remove loose .1.5-inch EnergyGuard Polyiso Insulation OB500 of base insulation (spatter),LRF-XF(spatter)or gravel,overstructural concrete deck OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced 0B500,6- (Optional)Additional layer OB500,6- Membrane/GAF 2-Part R-330. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter),LRF-XF(spatter)or -157.5 gravel,over structural concrete deck OB500(spatter) Existing smooth-or granule-surfaced BUR;smooth-or EverGuard TPO Fleece-Back granule surfaced SBS modified bitumen or gravel-surfaced 0B500,4- (Optional)Additional layer OB500,4- Membrane/GAF 2-Part R-331. BUR,brushed/spudded and vacuumed to remove loose Min.1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter),LRF-XF(spatter)or -200.0 gravel,over structural concrete deck OB500(spatter) Optional additional layers EverGuard TPO Fleece-Back Existing smooth-orgranule-surfaced BUR;smooth-or (Optional)Min.0.5-inch EnergyGuard Polyiso base insulation followed by granule-surfaced SBS modified bitumen or granule- Membrane/GAF 2-Part R-332. surfaced APP modified bitumen overstructural concrete Insulation,EnergyGuard Ultra,EnergyGuard RH, 0B500 min.0.25-inch DensDeck OB500 (spatter),LRF-XF(spatter)or -180.0 deck EnergyGuard RN Prime orSECUROCK Gypsum-Fiber Roof Board OB500(spatter) TABLE 713:WOOD OR SYSTEM TYPE C-2:PLATE-BONDED•.. (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener into the purlin.) System Substrate Attachment MDP Insulation Layer Roof Cover(Note 158) No. (Note 1) Fasteners(Note 11) Spacing (psf) Existing standing seam or lap seam metal Drill-Tec Purlin Fasteners or Drill-Tec Hex- One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.16 gauge(0.0598 Head Purlin Fasteners and Drill-Tec 18-inch o.c. R-333. combination, XHD Plates with RhinoBond Portable Bonding Tool,per -30.0 inch),50 ksi or min. gauge(0.105 in.),36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced through max.60-inch o.c. through ugh t to purlins Existing standing seam or lap seam metal One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.16 gauge(0.0598 combination,min.2- Drill-Tec Purlin Fasteners and Drilll Tec 18-inch o.c. XHD Tread Safe Plates with RhinoBond Portable R-334. inch),50 ksi or min.12 gauge 0.105 in.),36 inch total thickness, fastened t rou XHD Tread Safe Plates are along -30.0 ) 8 g ( ) fastened through to purlins purlins Bonding Tool,per manufacturers published ksi steel purlins spaced max.60-inch o.c. preliminarily fastened instructions. Existing standing seam or lap seam metal One or more layers,any Drill-Tec#14(min.1.05-inch embedment) 12-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO combination loose laid R-335. roof covers having nominal No.2 wood and Drill-Tec RhinoBond TPO XHD Plates along wood XHD Plates with RhinoBond Portable Bonding Tool,per -30.0 trusses spaced max.96-inch o.c. , are fastened through to wood supports supports manufacturer's published instructions. Existing standing seam or lap seam metal One or more layers,any Drill-Tec#14(min.1.05-inch embedment) 12-inch O.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO combination,min.2- and Drill-Tec RhinoBond TPO XHD Tread XHD Tread Safe Plates with RhinoBond Portable R-336. roof covers having nominal No.2 wood inch total thickness, Safe Plates are fastened through to wood along wood Bonding Tool,per manufacturers published -30.0 trusses spaced max.96-inch o.c. loose laid supports supports instructions. 11 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 152 of 156 NNEMO I etc. PLATE-BONDEDTABLE 713:WOOD OR STEEL-RECOVER SYSTEM TYPE C-2: (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel priorto drivingthe Purlin Fastenerintothe purlin.) System Substrate Attachment MDP Insulation Layer Roof Cover(Note 158) No. (Note 1) Fasteners(Note li) Spacing (psf) Existing standing seam or lap seam metal Drill-Tec Purlin Fasteners or Drill-Tec Hex One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.14 gauge(0.0747 Head Purlin Fasteners and Drill-Tec 18-inch o.c. R-337. combination, XHD Plates with RhinoBond Portable Bonding Tool,per -37.5 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced max.60-inch o.c. through to purlins Existing standing seam or lap seam metal One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.14 gauge(0.0747 combination,min.2- Drill-Tec Purlin Fasteners and Drilll Tec 18-inch o.c. XHD Tread Safe Plates with RhinoBond Portable R-338. inch),50 ksi or min.12 gauge 0.105 in.),36 inch total thickness, fastened t rou XHD Tread Safe Plates are along -37.5 ) 8 8 ( ) fastened through to purlins purlins Bonding Tool,per manufacturer's published ksi steel purlins spaced max.60-inch o.c. preliminarily fastened instructions. Existing standing seam or lap seam metal One or more layers,any Drill-Tec#14(min.1.05-inch embedment) 24-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO combination loose laid R-339. roof covers having nominal No.2 wood and Drill-Tec RhinoBond TPO XHD Plates along wood XHD Plates with RhinoBond Portable Bonding Tool,per -37.5 trusses spaced max.48-inch o.c. , are fastened through to wood supports supports manufacturer's published instructions. Existing standing seam or lap seam metal One or more layers,any Drill-Tec#14(min.1.05-inch embedment) 24-inch O.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO combination,min.2- and Drill-Tec RhinoBond TPO XHD Tread XHD Tread Safe Plates with RhinoBond Portable R-340. roof covers having nominal No.2 wood inch total thickness, Safe Plates are fastened through to wood along wood Bonding Tool,per manufacturers published -37.5 trusses spaced max.48-inch o.c. loose laid supports supports instructions. Existing standing seam or lap seam metal Drill-Tec Purlin Fasteners or Drill-Tec Hex- One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.16 gauge(0.0598 Head Purlin Fasteners and Drill-Tec 12-inch o.c. R-341. combination, XHD Plates with RhinoBond Portable Bonding Tool,per -45.0 inch),50 ksi or min. gauge(0.105 in.),36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced through max.60-inch o.c. through ugh t to purlins Existing standing seam or lap seam metal One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.16 gauge(0.0598 metal combination,min. Drill-Tec Purlin Fasteners and Drill-Tec 12-inch o.c. XHD Tread Safe Plates with RhinoBond Portable R-342. inch),50 ksi or min.12 gauge(0.105 in.),36 inch total thickness, fastened t rou XHD Tread Safe Plates are along purlins Bonding Tool,per manufacturer's published -45.0 ksi steel purlins spaced max.60-inch o.c. preliminarily fastened fastened through to purlins instructions. Existing standing seam or lap seam metal Drill-Tec#14(min.1-inch embedment)and 36-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-343. roof covers having nominal No.2 wood One or more layers,any Drill-Tec RhinoBond TPO XHD Plates or along wood XHD Plates or Drill-Tec RhinoBond TPO XHD Tread Safe trusses spaced max. munch o combination Drill-Tec RhinoBond TPO XHD Tread Safe supports,24- Plates with RhinoBond Portable Bonding Tool,per -52.5 Plates through to wood supports inch o.c. manufacturer's published instructions. Existing standing seam or lap seam metal Drill-Tec Purlin Fasteners or Drill-Tec Hex One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.16 gauge(0.0598 Head Purlin Fasteners and Drill-Tec 6-inch o.c. R-344. combination, XHD Plates with RhinoBond Portable Bonding Tool,per -67.5 inch),50 ksi or min. gauge(0.105 in.),36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced through max.72-inch o.c. through ugh t to purlins Existing standing seam or lap seam metal EverGuard TPO bonded to Drill-Tec RhinoBond TPO One or more layers,any Drill-Tec Purlin Fasteners and Drill-Tec roof covers having min.16 gauge(0.0598 6-inch o.c. XHD Tread Safe Plates with RhinoBond Portable R-345. combination,min.2- RhinoBond TPO XHD Tread Safe Plates are -67.5 inch),50 ksi or min.12 gauge(0.105 in.),36 inch total thickness, fastened through to purlins along purlins Bonding Tool,per manufacturers published ksi steel purlins spaced max.72-inch o.c. instructions. Existing standing seam or lap seam metal Drill-Tec#14(min.1-inch embedment)and 24-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-346. roof covers having nominal No.2 wood One or more layers,any Drill-Tec RhinoBond TPO XHD Plates or along wood XHD Plates or Drill-Tec RhinoBond TPO XHD Tread Safe 75 0 trusses spaced max.24-inch o.c. combination Drill-Tec RhinoBond TPO XHD Tread Safe supports,24- Plates with RhinoBond Portable Bonding Tool,per Plates through to wood supports inch o.c. manufacturer's published instructions. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 153 of 156 NNEMO I etc. PLATE-BONDEDTABLE 713:WOOD OR STEEL-RECOVER SYSTEM TYPE C-2: (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel priorto drivingthe Purlin Fastener intothe purlin.) System Substrate Attachment MDP Insulation Layer Roof Cover(Note 158) No. (Note 1) Fasteners(Note li) Spacing (psf) Existing standing seam or lap seam metal Drill-Tec#14(min.1-inch embedment)and 18-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-347. roof covers having nominal No.2 wood One or more layers,any Drill-Tec RhinoBond TPO XHD Plates or along wood XHD Plates or Drill-Tec RhinoBond TPO XHD Tread Safe 82 5 trusses spaced max.24-inch o.c. combination Drill-Tec RhinoBond TPO XHD Tread Safe supports,24- Plates with RhinoBond Portable Bonding Tool,per Plates through to wood supports inch o.c. manufacturer's published instructions. Existing standing seam or lap seam metal Drill-Tec Purlin Fasteners or Drill-Tec Hex One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO roof covers having min.14 gauge(0.0747 Head Purlin Fasteners and Drill-Tec 6-inch o.c. R-348. combination, XHD Plates with RhinoBond Portable Bonding Tool,per -97.5 inch),50 ksi or min.12 gauge(0.105 in.),36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced max.72-inch o.c. through to purlins Existing standing seam or lap seam metal One or more layers,any EverGuard TPO bonded to Drill-Tec RhinoBond TPO Drill-Tec Purlin Fasteners and Drill-Tec R-349. roof covers having min.14 gauge(0.0747 combination,min.2- RhinoBond TPO XHD Tread Safe Plates are al inch Lacs XHD Tread Safe Plates with manufacturer's ubl Portable 97 5 inch),50 ksi or min.12 gauge(0.105 in.),36 inch total thickness, fastened through to purlins along purlins Bonding Tool,per manufacturer's published ksi steel purlins spaced max.72-inch o.c. preliminarily fastened instructions. INSULATED,TABLE 7c:STEEL-RECOVER SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a r .25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener into the purlin.) System Deck(Note 1) Insulation Separator Sheet(Optional) Roof Cover(Note 15A) MDP No. Membrane Fasteners(Note 11) Attachment (Psf) Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec Purlin Fasteners and Drill-Tec 12-inch o.c.within min.6- Eyehook AccuSeam Plates or Eyehook inch wide laps spaced max. covers having min.16 gauge(0.0598 inch),50 layers,any Layer(3 oz/ydz)or EverGuard EverGuard R-350. Reel-Fast Plates or Drill-Tec#12 Barbed Perlin 84-inch Lacs to engage steel -30.0 ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO Fasteners with Drill-Tec 2.4"Barbed Seam purlins Laps sealed with 1.5- purlins spaced max.84-inch o.c. prelim.attached oz/ydz) Plate or Drill-Tec 2.4"Scoop Seam Plate inch heat weld. Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec Purlin Fasteners and Drill-Tec 2 12-inch o.c.within min.6- covers having min.14 gauge(0.0747 inch),50 layers,any Layer(3 oz/ydz)or EverGuard EverGuard #12 in.Double Barbed XHD Plates or Drill-Tec inch wide laps spaced max. R-351. ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO Perlin Fasteners with Drill-Tec S 84-inch Lacs to engage steel -30.0 Bar c purlins spaced max.84-inch o.c. prelim.attached oz/ydz) Barbed Seam Plate or Drill-Tec 2.4"Scoop purlins Laps sealed with 1.5- Seam Plate inch heat weld. Drill-Tec Hex Head Purlin Fasteners and Drill-Tec 2 in.Double Barbed XHD Plates, 12-inch o.c.in rows spaced Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation covers having min.16 gauge(0.0598 inch),50 layers,any Layer(3 oz/ydz)or EverGuard EverGuard Drill-Tec 2-3/8 in.Barbed XHD Plates, max.114-inch Lacs to engage R-352. ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO Drill-Tec Eyehook AccuSeam Plates or steel purlin.An 8-inch wide -30.0 purlins spaced max.114-inch o.c. prelim.attached oz/ydz) Drill-Tec#12 Purlin Fasteners with Drill- cover strip is heat welded Tec 2.4"Barbed Seam Plate or Drill-Tec over the stress plates. 2.4"Scoop Seam Plate NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 154 of 156 NNEMO I etc. TABLE 7c:STEEL-RECOVER SYSTEIVITYPED-1:INSULATED,MECHANICALLY ATTACHED ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener intothe purlin.) System Deck(Note 1) Insulation Separator Sheet(Optional) Roof Cover(Note 15A) MDP No. Membrane Fasteners(Note 11) Attachment (psf) Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec Purlin Fasteners and Drill-Tec 2- 12-inch o.c.within min.6- 2)or min.14 gauge(0.0747 inch),50 layers,any Layer(3 oz/ydz)or EverGuard EverGuard 3/8 in.Barbed XHD Plates or Drill-Tec#12 inch wide laps spaced max. R-353. ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO Purlin Fasteners with .4Tec"Scoop Barbed 84-inch Lacs to engage steel -37.5 Seam Plate or Drill-Tec 2 2.4 Seam purlin. Laps sealed with 1.5- purlins spaced max.84-inch o.c. prelim.attached oz/ydz) Plate inch heat weld. Drill-Tec Hex Head Purlin Fasteners and Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec 2 in.Double Barbed XHD Plates, 6-inch o.c.in rows spaced covers having min.16 gauge(0.0598 inch),50 layers,any Layer(3 oz/ydz)or EverGuard EverGuard Drill-Tec 2-3/8 in.Barbed XHD Plates, max.120-inch Lacs to engage R-354. ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO Drill-Tec Eyehook AccuSeam Plates or steel purlin.An 8-inch wide -45.0 purlins spaced max.120-inch o.c. prelim.attached oz/ydz) Drill-Tec#12 Purlin Fasteners with Drill- cover strip is heat welded Tec 2.4"Barbed Seam Plate or Drill-Tec over the stress plates. 2.4"Scoop Seam Plate Drill-Tec Purlin Fasteners and Drill-Tec 2 Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation in.Double Barbed XHD Plates,Drill-Tec 2- 6-inch o.c.within min.6-inch 3/8 in.Barbed XHD Plates,Drill-Tec wide laps spaced max.84- covers having min.16 gauge(0.0598 inch),50 layers,any Layer(3 oz/ydz)or EverGuard EverGuard R-355. ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO Eyehook AccuSeam Plates or Eyehook inch o.c.to engage steel -52.5 purlins spaced max.84-inch o.c. prelim.attached oz/ydz) Reel-Fast Plates or Drill-Tec#12 Purlin purlin. Laps sealed with 1.5- Fasteners with Drill-Tec 2.4"Barbed Seam inch heat weld. Plate or Drill-Tec 2.4"Scoop Seam Plate Drill-Tec Hex Head Purlin Fasteners and Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec 2 in.Double Barbed XHD Plates, 6-inch o.c.in rows spaced g gauge( ) y y y ( y z) Drill-Tec 2-3/8 in.Barbed XHD Plates, max.114-inch o.c.to engage covers having min.16 au a 0.0598 inch),50 layers,an Layer 3 oz/d or EverGuard EverGuard R-356. ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO Drill-Tec Eyehook AccuSeam Plates or steel purlin.An 8-inch wide -52.5 purlins spaced max.114-inch o.c. prelim.attached oz/ydz) Drill-Tec#12 Purlin Fasteners with Drill- cover strip is heat welded Tec 2.4"Barbed Seam Plate or Drill-Tec over the stress plates. 2.4"Scoop Seam Plate Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation 6-inch o.c.within min.6-inch covers having min.14 gauge(0.0747 inch),50 layers,any Layer(3 oz/ydz)or EverGuard EverGuard Drill-Tec Purlin Fasteners and Drill-Tec 2- wide laps spaced max.84- R-357. ksi or min.12 gauge(0.105 in.),36 ksi steel combination, Polymat Cushioning Layer(6 TPO 3/4 in.Barbed SXHD Plates inch o.c.to engage steel -60.0 purlins spaced max.84-inch Lacs prelim.attached oz/ydz) purlin. Laps sealed with 1.5- inch heat weld. NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization#32455 7'^Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 155 of 156 NNEMO I etc. BONDEDTABLE 7D:RECOVER APPLICATIONS SYSTEM TYPE F:NON-INSULATED, ROOF COVER System No. Substrate(Notes 1&12) Roof Cover(Note 15) MDP(psf) R-358. Existing asphaltic granule surfaced roof cover over wood,CWF or gypsum deck EverGuard TPO Fleece-Back Membrane/LRF-M or LRF-O,12-inch o.c. -45.0 R-359. Existing asphaltic granule surfaced roof cover over steel deck EverGuard TPO Fleece-Back Membrane/LRF-M or LRF-O,12-inch o.c. -60.0 Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule R-360. EverGuard TPO Fleece-Back Membrane/LRF-M or LRF-0,4-inch o.c. -60.0 surfaced APP modified bitumen over steel deck R-361. Existing asphaltic granule surfaced cap sheet EverGuard TPO Fleece-Back Membrane/LRF-M,6-inch o.c. -67.5 Existing granule surfaced BUR or granule surfaced SBS or APP modified bitumen over steel R-362. EverGuard TPO Fleece-Back Membrane/LRF-M,4-inch o.c. -105.0 deck R-363. Existing granule surfaced BUR or granule surfaced SBS or APP modified bitumen over steel EverGuard TPO Fleece-Back Membrane/LRF-0,4-inch o.c. -120.0 deck Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule R-364. EverGuard TPO Fleece-Back Membrane/LRF-M or LRF-O,4-inch o.c. -337.5 surfaced APP modified bitumen over structural concrete deck R-365. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece-Back Membrane/LRF-O,4-inch o.c.(for full coverage) -415.0 R-366. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece-Back Membrane/LRF-M,4-inch o.c.(for full coverage) -492.5 R-367. Existing asphaltic granule surfaced roof cover over wood,CWF or gypsum deck EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter),LRF-XF(spatter)or OB500 -45.0 (spatter) R-368. Existing smooth surfaced SBS modified bitumen over steel deck EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter),LRF-XF(spatter)or OB500 -60.0 (spatter) R-369. Existing (spatter) ng granule surfaced BUR or granule surfaced SBS or APP modified bitumen over steel r)d TPO Fleece-Back Membrane/GAF 2-Part(spatter),LRF-XF(spatter)or OB500 -120.0 dec Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter),LRF-XF(spatter)or OB500 R-370. -337.5 APP modified bitumen over structural concrete deck (spatter) R-371. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece-Back Membrane/GAF 2-Part(spatter) -497.5 R-372. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece-Back Membrane/Hot Asphalt -405.0 NEMO ETC,LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 certificate of Authorization#32455 Th Edition(2020)FBC NON-HVHZ EVALUATION Revision 47:06/07/2021 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 156 of 156