HomeMy WebLinkAboutREV1 ENCODE 2012-0722 OFFICE USE ONLY: DATE FILED: PERMIT# 2012-0722 REVISION FEE: RECEIPT# PLANNING & DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 5050 N Highway Al A,Hutchinson Island DETAILED DESCRIPTION OF PROJECT REVISIONS: Revision 1 Energy Code Compliance CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: OWNER/BUILDER INFORMATION: NAME: Mark walpert ADDRESS:4235 N Highway A1A CITY: Hutchinson Island STATE: FL ZIP: 34949 PHONE (DAYTIME: 203-778-9950 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC: 9123109 Revised 06130/17 CREScheck Software Version 4.7.2 �J( Compliance Certificate Project 5050 N. Highway AlA - Hutchinson Is FL Energy Code: 2017 Florida Building Code, Energy Conservation Location: Port Saint Lucie, Florida Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 7,391 ft2 Glazing Area 12% Climate Zone: 2 (307 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 5050 N. Highway AlA 5050 N. Highway AlA Heat Load USA Hutchinson Island, FL 34949 Hutchinson Island, FL 34949 Heat Load USA 112 junction Rd Hampton, NJ 08827 973-544-6800 info@HeatLoadUSA.com Envelope .. Additional checklist determine compliance with these requirements. Compliance: 26.0%Better Than Code Maximum UA: 1472 Your UA: 1090 Maximum SHGC: 0.25 Your SHGC: 0.18 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. 8TNWontlgrade 'radeOffsro use orconsiclere�in 1`f°ie l��"or performance compliance path in REScheck. Each slab on grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Prop.Gross Area Cavity Cont. Prop. Req. Perimeter Wall 1: Masonry Block with Empty Cells:lntegral 265 5.0 0.122 0.165 31 41 Insulation Window 1: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 15 0.270 0.400 4 6 SHGC: 0.18 Wall 2: Masonry Block with Empty Cells:lntegral 780 5.0 0.122 0.165 79 106 Insulation Door 1: Glass 34 0.270 0.400 9 13 SHGC: 0.16 Door 2: Glass 67 0.300 0.400 20 27 SHGC: 0.18 Window 1: lOD-v:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1 21 0.270 0.400 6 8 SHGC: 0.18 Window 2: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl firm mat, clr innr, 15 0.270 0.400 4 6 SHGC: 0.18 Wall 3: Masonry Block with Empty Cells:lntegral 126 5.0 0.122 0.165 15 21 Insulation Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 1 of12 Ver 2.rck Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Wall 4: Masonry Block with Empty Cells:lntegral 85 5.0 0.122 0.165 10 14 Insulation Wall 5: Masonry Block with Empty Cells:lntegral 208 5.0 0.122 0.165 20 26 Insulation Door 1: Glass 47 0.300 0.400 14 19 SHGC: 0.18 Wall 6: Masonry Block with Empty Cells:lntegral 651 5.0 0.122 0.165 69 94 Insulation Door 1: Solid 43 0.290 0.400 13 17 Window 1: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 6 0.270 0.400 2 3 SHGC: 0.18 Window 2: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 33 0.270 0.400 9 13 SHGC: 0.18 Wall 7: Masonry Block with Empty Cells:lntegral 972 5.0 0.122 0.165 88 118 Insulation Door 1: Glass 73 0.300 0.400 22 29 SHGC: 0.18 Door 2: Glass 21 0.300 0.400 6 8 SHGC: 0.18 Door 3: Glass 47 0.300 0.400 14 19 SHGC: 0.18 Door 4: Glass 47 0.300 0.400 14 19 SHGC: 0.18 Window 1: 1OD-v:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1 49 0.270 0.400 13 20 SHGC: 0.18 Window 2: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 16 0.270 0.400 4 7 SHGC: 0.18 Wall 8: Masonry Block with Empty Cells:lntegral 99 5.0 0.122 0.165 12 16 Insulation Wall 9: Masonry Block with Empty Cells:lntegral 162 5.0 0.122 0.165 15 20 Insulation Window 1: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 40 0.270 0.400 11 16 SHGC: 0.18 Wall 10: Masonry Block with Empty Cells:lntegral 451 5.0 0.122 0.165 43 58 Insulation Door 1: Glass 50 0.300 0.400 15 20 SHGC: 0.18 Door 2: Glass 47 0.300 0.400 14 19 SHGC: 0.18 Wall 11: Masonry Block with Empty Cells:lntegral 428 5.0 0.122 0.165 48 65 Insulation Window 1: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 11 0.270 0.400 3 4 SHGC: 0.18 Window 2: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 13 0.270 0.400 4 5 SHGC: 0.18 Window 3: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 7 0.270 0.400 2 3 SHGC: 0.18 Wall 12: Masonry Block with Empty Cells:lntegral 621 5.0 0.122 0.165 70 95 Insulation Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 2 of 12 Ver 2.rck Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Window 1: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 9 0.270 0.400 2 3 SHGC: 0.18 Window 2: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 10 0.270 0.400 3 4 SHGC: 0.18 Window 3: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 26 0.300 0.400 8 10 SHGC: 0.21 Wall 13: Masonry Block with Empty Cells:lntegral 126 5.0 0.122 0.165 15 21 Insulation Wall 14: Masonry Block with Empty Cells:lntegral 72 5.0 0.122 0.165 9 12 Insulation Wall 15: Masonry Block with Empty Cells:lntegral 91 5.0 0.122 0.165 11 15 Insulation Wall 16: Masonry Block with Empty Cells:lntegral 498 5.0 0.122 0.165 54 73 Insulation Door 1: Solid 25 0.290 0.400 7 10 Window 1: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 8 0.270 0.400 2 3 SHGC: 0.18 Window 2: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 10 0.270 0.400 3 4 SHGC: 0.18 Window 3: 4A5-2of:2 glazing, clr low-e outr, air gas, insulated fiberglass f 15 0.270 0.400 4 6 SHGC: 0.18 Wall 17: Masonry Block with Empty Cells:lntegral 994 5.0 0.122 0.165 106 143 Insulation Door 1: Solid 65 0.540 0.400 35 26 Window 1: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 15 0.270 0.400 4 6 SHGC: 0.18 Window 2: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 15 0.270 0.400 4 6 SHGC: 0.18 Window 3: 4A5-2ov:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 15 0.270 0.400 4 6 SHGC: 0.18 Window 4: 4B5-2fv:2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 15 0.270 0.400 4 6 SHGC: 0.18 Wall 18: Masonry Block with Empty Cells:lntegral 99 5.0 0.122 0.165 12 16 Insulation Wall 19: Masonry Block with Empty Cells:lntegral 72 5.0 0.122 0.165 9 12 Insulation Wall 20: Masonry Block with Empty Cells:lntegral 70 5.0 0.122 0.165 9 12 Insulation Floor 1: Slab-On-Grade:Unheated 3,146 0.0 1.042 0.064 0 0 Insulation depth: 0.0' Ceiling 1: Rf/clg ceiling, asphalt shingles roof mat, 4,091 0.020 0.030 82 123 mtl cons, r-10 deck ins Mechanical Equipment . - Air Source 9 HSPF, 16 SEER Air Source 9 HSPF, 16 SEER Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 3 of 12 Ver 2.rck Description Air Source 9 HSPF, 16 SEER Air Source 9 HSPF, 16 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in REScheck Version 4.7.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Rashid Burney Energy Auditor/HVAC Designer 10/29/2021 �as/iia�,�u^Te� Name-Title Signature Date Project Notes: job Number: 5050 N. Highway AlA- Hutchinson Is - FL Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 4 of12 Ver 2.rck CREScheck Software Version 4.7.2 �J( Inspection Checklist Energy Code: 2017 Florida Building Code, Energy Conservation Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and '❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the 0 building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7, energy code compliance for 403.8 lighting and mechanical systems. ❑Not Observable [PR3]1 Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: .14 Manual or other methods ❑Not Observable J Btu/hr Btu/hr ❑Not A licable approved by the code official. pp 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not [PR2]z on loads calculated per ACCA Cooling: Cooling: }j Manual J or other methods ❑Not Observable Btu/hr Btu/hr approved by the code official. ❑Not Applicable Refer to R403.7.1 for full details. Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA- Hutchinson Is FL- Page 5 of12 Ver 2.rck Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.2.1.3 ;A protective covering is installed '❑Complies [FO11]2 to protect exposed exterior ❑Does Not .14 insulation and extends a minimum of 6 in. below grade. ❑Not Observable IE]Not Applicable 402.1.2 Slab edge insulation R-value. R- R- ❑Complies see the Envelope Assemblies [FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values. ❑ Heated ❑ Heated ❑Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies see the Envelope Assemblies [FO3]1 depth/length. ❑Does Not table for values. 1' ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 !controls installed. ❑Does Not .AE]Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 6 of12 Ver 2.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1.3 U-factors of fenestration products' ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable 9EINot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 503.1.1.1 ❑Not Observable [FR2]1 ❑Not Applicable 402.1.1, Glazing SHGC value(area- SHGC: SHGC: ❑Complies see the Envelope Assemblies 402.3.2, weighted average). ❑Does Not table for values. 402.3.3 ❑ [FR3]1 Not Observable ❑Not Applicable 402.1.1, Door U-factor. U- U- ❑Complies see the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.4.1.1 ,Air barrier and thermal barrier ❑Complies [FR23]1 !installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate :52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where < 3 inches. Supply and return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17 above 105 °F or chilled fluids ❑Does Not 110 below 55 °F are insulated to >_R- ❑Not Observable 3. ❑Not Applicable 403.4.1 :Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R ❑Complies [FR18]2 >_R-3. ❑Does Not Ile ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 7 of12 Ver 2.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.5.5 ;Storage water heaters not ❑Complies [FR26]2 :equipped with integral heat traps ❑Does Not and having vertical pipe risers have heat traps installed on both ❑Not Observable the inlets and outlets. External ❑Not Applicable heat traps installed per code guildlines. 403.5.6.1. Service water heating systems ❑Complies 1 :are equipped with automatic ❑Does Not [FR27]2 temperature controls. ❑Not Observable ❑Not Applicable 403.5.6.1. ,A separate switch permits the ❑Complies 2 power supplied to electric service ❑Does Not [FR28]2 I water systems to be turned off.A ,separate valve permits the ❑Not Observable :energy supplied to the main ❑Not Applicable j burner(s)of combustion types of ;service water heating systems to be turned off. 403.5.6.2 :Water heating equipment meets Table 404.2 Table 404.2 ❑Complies [FR29]2 'minimum efficiencies of Table (required (required ❑Does Not C404.2 in Chapter 4 of the Ef): Ef): Florida Building Code, Energy ❑Not Observable Conservation, Commercial ❑Not Applicable Provisions. Equipment used to provide heating functions as part of a combination system satisfies all stated requirements for the ;appropriate water heating category. 403.5.6.2. Solar systems for domestic hot ❑Complies 1 water production satisfy energy ❑Does Not [FR30]2 factor requirements determinedlA from the Florida Solar Energy ❑Not Observable Center Directory of Certified ❑Not Applicable Solar Systems. 403.6 ;Automatic or gravity dampers are; ❑Complies [FR19]2 :installed on all outdoor air ❑Does Not :intakes and exhausts. ❑Not Observable ❑Not Applicable 403.6.2 Buildings designed to operate at ❑Complies [FR31]2 positive indoor pressure or have ❑Does Not mechanical ventilation meet the following criteria: 1) Maximum ❑Not Observable air-change-hour equal minimums ❑Not Applicable ;from ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, 2) No ventilation or air-conditioning system make-up air provided from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas, and 3) Air drawn from enclosed space(s) have walls insulated >= R-11 ,and ceiling >= R-19, space permitting, or R-10 otherwise. Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 8 of12 Ver 2.rck Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ;All installed insulation is labeled ❑Complies [IN13]2 :or the installed R-values ❑Does Not j provided. ❑Not Observable ❑Not Applicable 303.2 :Wall insulation is installed per ❑Complies [IN4]1 (manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies see the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable I 402.2. Walls, ceilings or floors common ❑Complies [IN14] to separate conditioned ❑Does Not tenancies are insulated to >= R- 11, space permitting. Mass ❑Not Observable common walls are insulated to ❑Not Applicable >= R-6. Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 9 of12 Ver 2.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 303.1.1.2. ;Ceiling insulation installed per ❑Complies 1, 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ftz. ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18130 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable 401.3 An energy performance level ❑Complies [F133]2 (EPL)display card must be ❑Does Not completed and certified by the builder before final approval of ❑Not Observable the building for occupancy. ❑Not Applicable Florida law(Section 553.9085, Florida Statutes) requires the EPL :display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.A copy of the EPL card form can be found in Appendix C of the "FBC, Energy Conservation". 402.1.1, :Ceiling insulation R-value. R- R- ❑Complies See the envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [FI1]1 ❑Not Applicable ❑Not Observable 402.2.3 'Vented attics with air permeable ❑Complies [FI22 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ba ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=7 ACH 50 = ACH 50 = ❑Complies [F117]1 lath. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.1 Each separate heating/cooling ❑Complies [F19]2 system has a thermostat ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Programmable thermostats ❑Complies [F19]z installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.3 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 40 Hot water boilers supplying heat ❑Complies [F126]z through one-or two-pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor I ❑Not Applicable temperature. ; 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 10 of12 Ver 2.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.3.2, All ducts, air handlers, and filter ❑Complies 403.3.2.1 boxes shall be constructed and ❑Does Not [F124]1 sealed in accordance with Section C403.2.9.2 of the ❑Not Observable Commercial Provisions of this ❑Not Applicable code.Air handler leakage designated by manufacturer at <=2%of design air flow. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4, Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies 403.3.2 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not [F14]1 <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. Duct tightness verified by testing in accordance with ANSI/RESNET/ICC 380-2016 by either individuals as defined in Section 553.993(5) or(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or(i), Florida Statutes,to be"substantially leak free" in accordance with Section R403.3.3. 403.3.6 ;Air handling units are not ❑Complies [F133]2 installed in attic. IE]Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [Fill]z systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 403.5.1.1 I Heated water circulation systems ❑Complies [F128]2 :have a circulation pump.The ❑Does Not ;system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 11 of12 Ver 2.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.5.1.2 Electric heat trace systems '❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 :Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104U. 403.5.4 Drain water heat recovery units EMRLJComplies [F131]2 :tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water :heat recovery units < 2 psi for :individual units connected to ,three or more showers. 403.6.1 :All mechanical ventilation system ❑Complies [F125]2 :fans not part of tested and listed ❑Does Not j HVAC equipment meet efficacy :and air flow limits. ❑Not Observable ❑Not Applicable 404.1 1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1. Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 5050 N. Highway AlA - Hutchinson Is FL Report date: 10/29/21 Data filename: c:\Users\rburn\AppData\Local\Check\REScheck\5050 N. Highway AlA - Hutchinson Is FL- Page 12 of12 Ver 2.rck