Loading...
HomeMy WebLinkAboutEnergy Calcs Man J 020822 - MarsanFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HOMECRETE - MARSAN - Builder Name: HOMECRETE HOMES Street: 1206 ROYAL PALM BLVD Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: HOMECRETE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41853.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=6.5 1643.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 210.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1817.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1817 a. Under Attic (Vented) b. N/A R=38.0 1817.00 ft2 R= Conditioned floor area below grade (ft2) 0 c. N/A ft2 R= ft2 7. Windows(250.2 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.29 109.17 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 300 SHGC: SHGC=0.29 b. U-Factor: Dbl, U=0.32 75.17 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 35.0 SEER:16.00 C. U-Factor: Dbl, U=0.29 65.83 ft2 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 5.914 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.273 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area C. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1817.2 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1817.20 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.138 Total Proposed Modified Loads: 54.55 PASS Total Baseline Loads: 61.52 1 hereby certify that the plans and spe fications covered by Review of the plans and S7,g7� this calculation are in compliance wit t e Florida Energ specifications covered by this O�TIiE 4V Code. calculation indicates compliance �,, ��,, '% _ _ :';� f0 with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE OWN ER/AGENT:����^- 1 BUILDING OFFICIAL: DATE: 'Q19Aa DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/4/2022 2:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HOMECRETE - MARSAN - Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot # Owner Name: HOMECRETE Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMECRETE HOMES Rotate Angle: 0 Street: 1206 ROYAL PALM SL Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1817 18170 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BED 1 175 1750 No 1 3 1 No Yes Yes 2 BATH 2 60 600 No 0 1 No Yes Yes 3 BED 2 168 1680 No 1 1 No Yes Yes 4 DINING ROOM 288 2880 No 0 1 No Yes Yes 5 GREAT ROOM 225 2250 No 0 1 No Yes Yes 6 KITCHEN 265 2650 No 0 1 No Yes Yes 7 LAUNDRY 70 700 No 0 1 No Yes Yes 8 MASTER TOILET 26 260 No 0 1 No Yes Yes 9 MASTER BATH 144 1440 No 0 1 No Yes Yes 10 WIC MASTER INT 48 480 No 0 1 No Yes Yes 11 WIC MASTER EXT 48 480 No 0 1 No Yes Yes 12 MASTER SUITE 300 3000 No 2 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 1 26 ft 0 175.2 ft2 ___ 0 1 0 2 Slab -On -Grade Edge Insulatio BATH 2 6 ft 0 60 ft2 _--_ 1 0 0 3 Slab -On -Grade Edge Insulatio BED 2 26 ft 0 168 ft2 0 1 0 4 Slab -On -Grade Edge Insulatio DINING ROOM 17 ft 0 288 ft2 0 1 0 5 Slab -On -Grade Edge Insulatio GREAT ROOM 14 ft 0 225 ft2 _-__ 0 1 0 2/4/2022 2:27 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio KITCHEN 8 ft 0 265 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulatio LAUNDRY 7 ft 0 70 ft' 1 ____ 0 0 8 Slab -On -Grade Edge Insulatio MASTER TOILET O ft 0 26 ft2 1 0 -___ 0 9 Slab -On -Grade Edge Insulatio MASTER BATH 23.5 ft 0 144 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulatio WIC MASTER IN 1 ft 0 48 ft2 0 1 0 11SIab-On-Grade Edge Insulatio WIC MASTER EX 8 ft 0 48 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio MASTER SUITE 38 ft 0 300 ft2 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1915 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 1 38 Blown 175 ft2 0.1 Wood 2 Under Attic (Vented) BATH 2 38 Blown 60 ft2 0.1 Wood 3 Under Attic (Vented) BED 2 38 Blown 168 ft2 0.1 Wood 4 Under Attic (Vented) DINING ROOM 38 Blown 288 ft2 0.1 Wood 5 Under Attic (Vented) GREAT ROOM 38 Blown 225 ft2 0.1 Wood 6 Under Attic (Vented) KITCHEN 38 Blown 265 ft2 0.1 Wood 7 Under Attic (Vented) LAUNDRY 38 Blown 70 ft2 0.1 Wood 8 Under Attic (Vented) MASTER TOILET 38 Blown 26 ft2 0.1 Wood 9 Under Attic (Vented) MASTER BATH 38 Blown 144 ft2 0.1 Wood 10 Under Attic (Vented) WIC MASTER IN 38 Blown 48 ft2 0.1 Wood 11 Under Attic (Vented) WIC MASTER EX 38 Blown 48 ft2 0.1 Wood 12 Under Attic (Vented) MASTER SUITE 38 Blown 300 ft2 0.1 Wood WALLS Adjacent Cavity Width Space Height Sheathing Framing Solar Below 0 _ 1 S Exterior Concrete Block - Int Insul BED 1 6.5 17 6 8 0 140.0 ft2 0 0 0.5 0 _ 2 W Exterior Concrete Block - Int Insul BED 1 6.5 15 0 8 0 120.0 ft2 0 0 0.5 0 _ 3 N Exterior Concrete Block - Int Insul BATH 2 6.6 11 3 8 0 90.0 ft2 0 0 0.5 0 4 W Exterior Concrete Block - Int Insul BATH 2 6.5 6 0 8 0 48.0 ft2 0 0 0.5 0 2/4/2022 2:27 PM EnergyGaugel) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 IMPI IT CI IMUADV riucr�vl is r ncnnn-r WALLS Adjacent Space Cavity Width R-1/alue Et In Height Et In area Sheathing Framing R-14alue Fraction Solar Below - 5 N Exterior Concrete Block - Int Insul BED 2 6.5 17 6 8 0 140.0 ft2 0 -Abe 0 0.5 0 _ 6 W Exterior Concrete Block - Int Insul BED 2 6.5 15 0 8 0 120.0 ft2 0 0 0.5 0 7 S Exterior Concrete Block - Int InsDIINING ROO 6.5 21 3 8 0 170.0 ft2 0 0 0.5 0 _ 8 N Exterior Concrete Block - Int Ins(DREAT ROO 6.5 17 6 8 0 140.0 ft2 0 0 0.5 0 9 N Exterior Concrete Block - Int InsulKITCHEN 6.5 10 0 8 0 80.0 ft2 0 0 0.5 0 10 E Exterior Concrete Block - Int InsMASTER BA 6.5 16 11 8 0 135.3 ft2 0 0 0.5 0 _ 11 E Exterior Concrete Block - Int Inst WIC MASTE 6.5 10 0 8 0 80.0 ft2 0 0 0.5 0 _ 12 N Exterior Concrete Block - Int InsMASTER SUI 6.5 17 6 8 0 140.0 ft2 0 0 0.5 0 _ 13 E Exterior Concrete Block - Int InsMASTER SUI 6.5 20 0 8 0 160.0 ft2 0 0 0.5 0 -14 W Exterior Concrete Block - Int InsMASTER SUI 6.5 10 0 8 0 80.0 ft2 0 0 0.5 0 _ 15 E Garage Frame - Wood MASTER BA 11 21 0 10 0 210.0 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood DINING ROO None 39 5 8 40 ft2 2 E Wood MASTER BA None .39 2.8 8 22.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Double (Tinted) Yes 0.29 0.26 N 32.9 ft2 1 ft 6 in 1 ft 0 in None None 2 W 4 Metal Double (Tinted) Yes 0.29 0.29 N 11.0 ft2 1 ft 6 in 1 ft 0 in None None 3 W 6 Metal Double (Tinted) Yes 0.29 0.29 N 17.1 ft2 1 ft 6 in 1 ft 0 in None None 4 S 7 Metal Double (Tinted) Yes 0.29 0.26 N 32.9 ft2 1 ft 0 in 1 ft 0 in None None 5 N 8 Metal Double (Tinted) Yes 0.32 0.26 N 75.2 ft2 8 ft 0 in 1 ft 0 in None None 6 N 9 Metal Double (Tinted) Yes 0.29 0.29 N 17.1 ft2 9 ft 0 in 1 ft 0 in P';ne None 7 E 10 Metal Double (Tinted) Yes 0.29 0.29 N 14.0 ft2 ft 6 in 1 ft 0 in None None 8 N 12 Metal Double (Tinted) Yes 0.29 0.29 N 32.9 ft2 1 ft 6 in 1 ft 0 in None None 9 W 14 Metal Double (Tinted) Yes 0.29 0.29 N 17.1 ft2 31 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 469 ft2 469 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2119.8 116.3 218.34 .1381 7 2/4/2022 2:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPIIT AI IMMAPV rucrtci ler oeanoF HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 16 35 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS J --- Supply -- V ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft2 Attic 150 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb ] Mar Heating Jan f XFeb f X] Mar A r Apr f Jul May Jun Jul Ma rj Junrl Au AuSep ri Se ri Nov Oct HX Oct NovX� W Dec Dec Venting Jan [ Feb X Mar A r [ Ma Jun Jul Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 PM 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 PM 68 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BED 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BED 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER TOILET 2/4/2022 2:27 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 1-UKM K405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibsisq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC MASTER INT Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC MASTER EXT Default 8 Ibs/s .ft. ft2 ft 0.3 MASTER SUITE 2/4/2022 2:27 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.29 SHGC: SHGC=0.29 b. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.26 c. U-Factor: Dbl, U=0.29 SHGC: SHGC=0.26 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): NIA 1206 ROYAL PALM BLVD, FORT PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=6.5 1643.30 ft2 b. Frame - Wood, Adjacent R=11.0 210.00 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 No 11, Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=38.0 1817.00 ft2 1817 b. N/A R= ft2 Area c. N/A R= ft2 109.17 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 300 75.17 ft2 13. Cooling systems kBtu/hr Efficiency 65.83 ft2 a. Central Unit 35.0 SEER:16.00 ft2 5.914 ft. 0.273 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1817.20 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. I Builder Signature: Date: Address of New Home: City/FL Zip: _'7 e YC�_ c3q 42 kBtu/hr Efficiency 34.6 HSPF:8.50 Cap: 50 gallons EF: 0.92 Pstat QITHE srgr 10 C�D WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/4/2022 2:31 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project Summary L"*J��5 Entire House Lindstrom Air Conditioning 358' W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954420-0064 Web: www lindstromaircom Proiect Information For: HOMECRETE Notes: MARSAN RES. Desicin Information Job: Date: 1-2022 By: LINDSTROM Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Inside db 70 OF Outside db Inside db 90 75 OF OF Design TD 28 OF Design TD 15 OF Daily range Relative M humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 18089 Btuh Ducts 5925 Btuh Central vent (0 cfm) 0 Btuh ( none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24013 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Coplingg Area (ft2) 1817 1817 Volume (ft3) 18172 18172 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 115 61 Heating Equipment Summary Make CARRIER Trade Model CH16NA036 AHRI ref 204863004 Efficiency 8.5 HSPF Heating input Heating output 34600 Btuh @ 47°F Temperature rise 26 OF Actual air flow 1200 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0.10 in H2O Space thermostat Capacity balance point = 0 OF Backup: CARRIER 5 KW Input = 7 kW, Output = 24512 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 14057 Btuh Ducts 11033 Btuh Central vent (0 cfm) 0 Btuh ( none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Equipment sensible load 25090 Btuh Latent Cooling Equipment Load Sizing Structure 3330 Btuh Ducts 2592 Btuh Central vent (0 cfm) 0 Btuh (pone) Equipment latent load 5922 Btuh Equipment Total Load (Sen+Lat) 31012 Btuh Req. total capacity at 0.80 SHR 2.6 ton Cooling Equipment Summary Make CARRIER Trade Cond CH16NA036 Coil FX4DNF037 AH R I ref 204863004 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 28000 Btuh 7000 Btuh 35000 Btuh 1200 cfm 0.048 cfm/Btuh 0.10 in H2O 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -fk wrightsoTt^ 2022-Feb-04 13:48:54 At& ...,..- w•••• •.•-.•�-.��. Right -Suite® Universal2019 19.0.12 RSU08398 Page 1 ...Y\A- MANUAL J\HOMECRETE - MAR SAN- FT PIERCE:;up Calc = MJ8 Front Door faces: N Righ"o Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Far 9541-AIMMad wmr,• u,w,. Job: Date: 1-2022 By: LINDSTROM 1 2 Room name Exposed wall tire use Ho Entire Dft 3 Room height 1 26. 4 Room dimensions 10.0 ft 10.0 ft heat/cod 5 Room area 1817.2 ft2 175.2 ft'14.6 x 12.0 ft Ty Construction U-value or HTM Area ' (ft=) Load number (Btuh/ft'-°F) (BtutJft�) I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vb13A-60cs 0.111 n 3.11 1.48 590 465 1445 686 0 0 0 0 1 D-h2om 1D-h2omd 0.290 n 8.12 13.57 33 0 268 448 0 0 0 0 1 D-h2om 0.320 0.320 n n 8.96 8.96 14.02 14.02 75 17 0 672 1052 0 0 0 0 11 13A-60cs 0.111 a 3.11 1.48 376 0 361 152 1122 238 533 0 0 0 0 0 0 0 �-G 1 D-h2om 13A-60cS 0.290 0.111 a 8.12 44.61 14 2 114 624 0 0 0 0 0 1 D-h2om 0.290 s s 3.11 8.12 1.48 13,57 310 33 222 66 690 268 328 448 140 0 107 333 158 1 D-h2om 11 DO 0.290 s 8.12 13.57 33 66 268 448 33 0 33 0 268 0 448 W 13A-600s 0.390 0.111 s w 10.92 3.11 10.34 1.48 22 368 22 323 240 1004 227 477 0 120 0 120 0 0 1 D-h2om 0.290 w 8.12 43.93 11 2 89 483 0 0 373 0 177 0 1 D-h2om 0.290 w 8.12 45.01 17 2 138 765 0 0 0 0 1 D-h2om 12B-Obw 0.290 0.097 w 8.12 13.57 17 34 138 231 0 0 0 0 L-•D 11 DO 0.390 - a 2.72 10.92 0.61 10.34 210 22 188 22 511 240 115 227 0 0 0 0 0 0 C F 16B-38md 22A-tpm 0.026 a 0.73 1.30 1817 1817 1323 2362 175 175 0 128 0 228 1.180 a 33.04 0.00 1817 178 5865 0 175 26 859 0 6 c) AED excursion 45 100 Envelope loss/gain 14547 9739 1960 911 12 a) Infiltration b) Room ventilation 3542 999 560 158 0 0 0 0 13 Internal gains: occupants Q 230 4 920 1 230 Appliances/other 2400 0 Subtotal (lines 6 to 13) 1W89 14057 2521 1299 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 18089 14057 2521 1299 33% 78% 5925 11033 33% 78% 826 1019 Total room load Air required ad 24013 25M 3346 2318 1200 1200 1671 111 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed �- wrtgtntsoft ��� - • - --• Right -Suite® 2022•Feb-04 13:48:54 Universal 2019 19.0.12 RSU08398 Page 1 ...Y%A- MANUAL JIHOMECRETE - MARSAN- FT PIERCE.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: " Entif'e House Date: 1-2022 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954.420-0064 Web www lindstromaircc 1 Room name 2 Exposed wall BATH 2 BED 2 3 Room height 6.0 ft 26.0 ft 4 Room dimensions 10.0 ft heat/cool 10.0 ft heat/cool 5 Room area 6 0 x 10.0 ft x 14.0 ft 60.0 ftz 168 0 ft�12.0 Ty Constructic:l U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuft/W-9F) (BtulUft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 Vh13A-6ocs ID-h2om 0.111 n 3.11 1.48 90 90 280 133 140 140 435 207 1D-h2omd 0.290 0.320 n n 8.12 8.96 13.57 14.02 0 0 0 0 0 0 0 0 0 0 1D-h2om 0.320 n 8.96 14.02 0 0 0 0 0 0 0 0 0 0 0 11 VL-G 13A-6ocs 0.111 e 3.11 1.48 0 0 0 0 0 0 0 0 1D-h2om 0.290 e 8.12 44,61 0 0 0 0 0 0 0 0 0.111 s 3.11 1.48 0 0 0 0 0 0 0 �513A-6ocs 1D-h2om 0.290 s 8.12 13.57 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.12 13.57 0 0 0 0 0 0 0 0 D Wj 11DO 13A-6ocs 0.390 0.111 s 10.92 10.34 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w w 3.11 8.12 1.48 43.93 48 11 37 115 55 120 103 320 152 1 D-h2om 0.290 w 8.12 45.01 0 1 0 89 0 483 0 0 17 0 0 0 1 D-h2om 0.290 w 8.12 13.57 0 0 0 0 0 1 0 138 735 D 12B-Obw 0.097 - 2.72 0.61 0 0 0 0 0 0 0 0 11 DO 0.390 e 10.92 10.34 0 0 0 0 0 0 0 0 0 0 C F 166-38md 22A-tpm 0.026 1.180 e 0.73 1.30 60 60 44 78 158 168 122 218 e 33.04 0.00 60 6 198 0 168 26 859 0 6 c) AED excursion 220 297 Envelope loss/gain 726 969 1875 1639 12 a) Infiltration b) Roorr, ventilation 297 84 560 158 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 ~ 1 Appliances/other 0 230 Subtotal (lines 6 to 13) 1023 1053 2435 2027 Less external load 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 15 Duct loads 1023 1053 2435 2027 330% 78% 335 826 33% 78% 798 1591 Total room load Air required (cfm) 1359 1879 3233 3618 68 90 162 173 Calculations approved by ACCA to rrleet all requirements of Manual J 8th Ed. _ 4 - 2022-Feb-04 13:48:54 Right -Suite® Universal 2019 19.0.12 RSU08398 Page 2 `�A ...Y1A- MANUAL JIHOMECRETE - MARSAN- FT PIERCE.rup Calc = MJ8 Front Door faces: N Right-J@ Worksheet Entire ;House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-420-OOM4 wah www Job: Date: 1-2022 By: LINDSTROM 1 1 Room name 2 Exposed wall DINING ROOM GREAT ROOM 3 Room height 17.0 ft 14.0 ft 4 Room dimensions 10.0 It heat/cool 10.0 ft heat/cool 5 Room area 18.0 x 16.0 ft 15.0 x 15.0 ft 288.0 ft2 225.0 ft' Ty Construction U-value Or HTM _ Area (ft') Load Area (W) Load number (Btuhrft? "F) (BtuNftx) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 vvv��[f 13A-6•ocs 0.111 n 3.11 1.48 �0 0 0 0 140 65 202 96 I-G IL-_�G ID-h2om 0.290 r, 8.12 13.57 0 0 0 0 0 0 0 0 ID-h2omd 1 D-h2om 0.320 0,320 r r 8.96 8.96 14.02 0 0 0 0 75 0 672 1052 11 V?J 13A-6ocs 0,111 e 3.11 14.02 1,48 0 0 0 0 0 0 0 0 0 0 0 0 L_ ( 1D-h2om 0.290 e 8.12 44.61 0 0 0 0 0 0 0 0 0 0 0 Vh13A-6ocs 0,111 s 3.11 1.48 170 115 357 170 0 0 0 0 ID-h2om 0.290 s 8.12 13.57 33 33 268 448 0 0 0 0 0 1 D-h2om 0.290 s 8.12 13.57 0 0 0 0 0 0 0 0 W 11DO 13A-6ocs 0.390 0.111 s 10.92 10.34 22 22 240 227 0 0 0 0 1 D-h2om 0.290 w w 3.11 8.12 1.48 43.93 0 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8,12 45,01 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.12 13.57 0 0 0 0 0 0 0 0 0 IL-D 12B-Obw 0.097 - 2.72 0.61 0 0 0 0 0 0 0 0 11 DO 16B-33md 0.390 e 10.92 10.34 0 0 0 0 0 0 0 0 C F 22A-tpm 0.026 1.180 e e 0.73 33.04 1.30 0.00 268 288 288 210 374 225 225 164 293 17 562 0 225 14 463 0 6 c) AED excursion -47 109 Envelope loss/gain 1637 1173 1500 1331 12 a) Infiltration b) Room ventilation 366 103 302 85 0 0 0 0 13 Internal gains. Occupants @ 230 3 0 0 Appliances/ot w p 0 0 Subtotal (lines 6 to 13) 2003 _ 1276 1802 1416 Less external load 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 0 0 14 15 Subtotal Duct loads 2003 1276 1802 1416 331/, 78% 656 1001 33% 78% 590 1112 Total room load Air required (cfm) 2660 2277 2392 252E 133 109 120 121 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ +}+ wrlgf�tso�t •• - � � Right -Suite® Universal 2019 19.0.12 RSLJ08398 20<:2-Feb-0413:48:54 Page 3 ... Y\A- MANUAL J\HOMECRETE - MARSAN- FT PIERCE.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: Entrre House Date: 1-2022 Lindstrom Air ConditioningBy: LINDSTROM 3581 W MCNAB RD, POMPANO 3EACH, FL 33069 Phone: 954-421-4117 Fax 954.420-ons4 VV .n• wW,., r, a., 1 Room Warne 2 Exposed wall KITCHEN LAUNDRY 3 Room height 8.0 ft 7.0 ft 4 Room dimensions 10.0 ft heat/cool 10.0 ft heat/cool 5 Room area 13.3 x 20.0 ft 10.0 x 7.0 ft 265.0 ft' 70.0 ft2 Ty Construction U-value Or H-M Area (ft2) Load Area (ft') Load number (Btuh/ft2-'F) (BtuIVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-6ocs 0.111 n 3.11 1.48 80 63 196 93 0 0 0 V 1D-h2om 0.290 n 8.12 13.57 0 0 0 0 0 0 0 0 1D-h2omd 0.320 n 8.96 14.02 0 0 0 0 0 0 0 0 11 VL-6 ID-h2om 13A-6ocs 0.320 0.111 n 8.96 14.02 17 0 152 238 0 0 0 0 0 1D-h2om 0.290 e a 3.11 8.12 1.48 44,61 0 0 0 0 0 0 0 0 0 0 0 0 13A-6ocs 0.111 s 3.11 1.48 0 0 0 0 0 0 0 0 ID-h2om 0.290 s 8.12 13.57 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0,290 s R 12 1& 57 0 0 0 0 0 0 0 0 D W 11 DO 13A-6ocs 0.390 0.111 s w 'I O.92 3.11 10.34 1.48 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.12 43.93 0 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0,290 w 8.12 45.01 0 0 0 0 0 0 0 0 0 0 1 D-h2om 128-Obw 0.290 0.097 w 8.12 13.57 0 0 0 0 0 0 0 0 0 D 11 DO 0.390 - e 2.72 10.92 0.61 10.34 0 0 0 0 0 0 70 48 130 29 C F 16B-38md 22A-tpm 0.026 e 0.73 1.30 265 265 0 193 0 345 22 70 22 70 240 51 227 91 1.180 e 33.04 0.00 265 8 264 0 70 7 231 0 6 c) AED excursion -180 .68 Envelope loss/gain 805 496 653 280 12 a) Infiltration 172 49 0 0 b) Room ventilation 0 _ 0 0 0 13 Intemal gains. Occupants @ 230 0 p 0 Appliances/other 1800 0 600 Subtotal (lines 6 to 13) 978 2344 653 880 Less external load 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 i5 Subtotal Duct loads 978 2344 0 653 0 880 33°� 78% 320 1840 33% 78% 214 691 Total room load Air required (cfm) 125 184 4200 ---T-6 867 1571 43 75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wr�gF�ttsott �- 2022-Feb-04 13:48:54 tP` Right -Suite® Universal 2019 19.0.12 RSU08398 Page 4 ...Y1A- MANUAL JIHONECRETE - MARSAN- FT PIERCE.rup Calc = MJ8 Front Door faces: N CPIPI�AW Right-J® VUorksheet Job: Entire House Date: 1-2022 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD. POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: s.4-4?n-nnrA won ,.,,.- ii. A 1 2 Room name Exposed wall MASTER TOILET 4 Vv MASTER BATH 3 Room height 4•0 ft 23.5 ft 4 Room dimensions 10.0 ft heat/cool 10.0 ft heaUcooi 5 Room area 4.0 x 6.5 ft 12.0 x 12.0 ft 26.0 ft2 144.0 ft2 TY Construction U-value Or HTM Area (W) Load Area (ftj Load number (Btuh/ft' °F) (Btulvftj or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V 0.111 n 3.11 1.48 0 0 0 0 0 0 1 D-h2om 0.290 n 8.12 13.57 0 0 0 0 0 0 0 0 0 j13A-6ocs ID-h2omd 0,320! n 8.96 14.02 0 0 0 0 0 0 0 0 0 11 1D-h2om 13A-6ocs 0.320 0.111 n a 8.96 3.11 14.02 1.48 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 a 8.12 44.61 0 0 0 0 0 0 0 135 14 121 376 179 13A-6ocs 0.111 s 3.11 1.48 0 0 0 0 0 1 0 114 624 1D-h2om 0.290 s 8.12 13.57 0 0 0 0 0 0 0 0 0 0 1D-h2om 11 Do 0,290 s 8.12 13.57 0 0 0 0 0 0 0 0 13A-6ocs 0.390 0.111 s w 10.92 3.11 10.34 1,48 0 0 0 0 0 0 0 0 0 0 0 ID-h2om 0.290 w 8.12 43.93 0 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.12 45.01 0 0 0 0 0 0 0 0 0 1 D-h2om 126-0bry 0.290 0.097 w - 8.12 2.72 13.57 0.61 0 40 0 0 0 0 0 0 0 11 DO 0.390 a 10.92 10.34 0 40 0 109 0 24 0 100 0 100 272 61 C F 16B-38md 22A-tpm 0.026 1.180 a 0,73 1.30 26 26 19 34 144 0 144 0 105 0 187 a 33.04 0.00 26 4 132 0 144 24 776 0 6 c) AED excursion -4 9 Envelope loss/gain 260 54 1643 1060 12 a) Infiltration 0 0 b) Room ventilation 291 82 0 0 0 0 13 1ntemal gains: Occupants @ 230 0 0 0 Appliances/other 0 0 0 Subtotal (lines 6 to 13) 260 54 1934 1142 Less external load 0 0 Less transfer 0 0 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 260 54 1934 1142 33% 78% 85 42 33% 78% 633 8% Total room load Air required (cfm) 345 97 2567 2038 1715 128 97 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrlghtso>Ft rIC�A - � Right -Suite® Universal 2019 19.0.12 RSU08398 2022-Feb-04 13:48:54 Page 5 ...Yb4- MANUAL JIHOMECRETE - MARSAN- FT PIERCE.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: Entire House Date: 1-20.22 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAS RD. POMPANO BEACH, FL 33069 Phone: 954-421-4117 FaY q.Se-eon-nnae W.h ,.,,.,,., 1; A 1 Room name J 1411p1t 2 Exposed wall WIC MASTER INT c WIC MASTER EXT 3 Room height 0 ft 8.0 ft 4 Room dimensions 10.0 ft heat/cool 10.0 ft heat/cool 5 Room area 6.0 x &0 ft 8.0 x 6.0 `t 48.0 ftz � O ft' Ty Construction U-value Or H'TM Area (W) Load Area (ft') Load number (Btuh/ft? °F) (BtuNft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NiP/S Heat Cool Gross N/P/S Heat 501 6 Vh13A-6ocs 0,111 n 3A1 1.48 0 0 0 0 0 1D-h2om 0.290 n 8.12 13.57 0 C 0 0 0 0 0 0 0 10-h2omd 0.320 n 8.96 14.02 0 C 0 0 0 0 0 0 11 ID-h2om 13A-6ocs 0.320 0.111 n 8.96 14.02 0 C 0 0 0 0 0 0 0 0 V 1 D-h2om 0.290 e a 3.11 R 12 1.48 44.61 0 0 C 0 0 0 80 80 249 118 0.111 s 3.11 1.48 0 0 0 0 0 0 0 0 0 0 T�13A-6cOs 1 D-h2om 0.29.29 0 s 8.12 13.5757 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.12 13.57 0 0 0 0 0 0 0 D Nl 11 DO 13A-6ocs 0.390 0.111 s 10.92 10.34 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w w 3.11 8.12 1A8 43.93 0 0 C 0 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.12 45.01 0 C 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.12 13.57 0 C 0 0 0 0 0 0 0 12B-Otra 0.097 - 2.72 0.61 0 C 0 0 0 0 0 11 DO 16B-38md 0.390 e 10.92 10.34 0 C 0 0 0 0 0 0 0 0 C F 22A-tpm 0.026 1.180 e e 0,73 33.04 1.30 0.00 48 48 48 C 35 62 48 48 35 62 0 0 48 8 264 0 6 c) AED excursion -4 16 Envelope loss/gain 35 58 548 164 12 a) Infiltration b) Room ventilation 0 0 172 49 0 0 0 0 13 Intemal gains Occupants @ 230 0 0 0 Appliances/other 0 0 0 Subtotal (lines 6 to 13) 35 58 720 213 Less extemal load O 0 i Less transfer 0 0 0 0 Redistribution 0 0 14 Subtotal 0 0 0 0 15 Duct loads 33% 78% 35 11 58 45 33°io 78% 720 236 213 167 ad TotaFwedl -----7 Air r(cfm} 1:31 103956380 5 48 18 Calculations approved by ACCA to meet all ree uirements of Manual J 8th Ed. -}+- 2022-Feb-04 13 48 54 Right-SuiteG Universal 2019 19.0.12 RSU08398 Page 6 ...Y\A- MANUAL J\HOMECRETE - MARSAN- FT PIERCE.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: - L�t Etltlt"e House Date: 1-2022 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Pt -.one: 954-421-4117 Far aA,e-A90_nnae mt.k ,.,..,,., i, a 1 Room name 2 Exposed wall MASTER SUITE 3 Room height 38.0 ft 4 Room dimensions 10.0 It heat/cool 5 Room area 15.0 x 20-0 ft 300.0 ft' Ty Construction number U-value Or HTM Area (ft') Load Area Load ( Btuh/ftx-"F ) (BtutVft2) or perimeter (ft) (Btul1) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coot 6Vb13A-6ors 1 D-h2orn 0.111 n 3.11 1.48 140 107 333 158 1D-h2ornd 0.290 0.320 n n 8.12 8.96 13.57 14.02 33 0 0 268 448 11 UfJ 1 D-h2orn 13A-60os 0.320 0.111 n e 8.96 3.11 14.02 0 0 0 0 0 0 0 I-- G 1 D-h2orn 0.290 a 8.12 1.48 44.61 160 0 160 0 497 0 2:36 13A-6om 0.111 s 11 0 0 0 0 0 ID-h2orn 0.290 290 s . 8.12 3.57 13.57 0 0 0 0 1 D-h2orn 0.290 s 8.12 13.57 0 0 0 0 W�13A-6ocs 11 DO 0.390 0.111 s w 10.92 3.11 10.34 1.48 0 80 0 63 0 0 1 D-h2orn 0.290 w 8.12 43.93 0 0 196 0 93 0 ID-h2orn 0.290 w 8.12 45.01 0 0 0 0 1 D-h2orn 126-Obvv 0.290 0.097 w 8.12 2.72 13.57 17 17 138 2:31 11 DO 0,390 - e 10.92 0.61 10.34 0 0 0 0 0 0 0 0 C F 1613-38mc! 22A-tpm 0.026 1.180 a 0.73 1.30 300 300 218 390 a 33.04 000 300 38 1256 0 6 c) AED excursion 48 Envelope loss/gain 2906 1604 12 a) Infiltration 819 231 b) Room ventilation i 0 0 13 Internal gains: Occupants @ 230 2 4,30 Appliances/other 0 Subtotal (lines 6 to 1:3) 3725 2295 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 15 Subtotal Duct loads 3725 229 33% 78% 1220 1801 LITotal room load 4945 4097 Air required (cfrn) 247 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrighlsott �^�A - -• MRight-Suite® Universal 2019 19.0.12 RSU08398 2022-Feb-04 13:48:54 Page 7 ..Y\A- MANUAL J\HOMECRETE - MARSAN- FT PIERCE.rup Calc = J8 Front Door faces: N