HomeMy WebLinkAboutGAP 30# Underlayment Product Approval8/5/2021
Business• Professional 1
BCIS Home 11 Log In User Registration Hot Topics
dprFi nda
Product Approval
USER: Public user
Florida Building Code Online
MWO
NO :..:.
Submit Surcharge stats & facts Publications Contact us BCIS Site Map Links Search
Product Appro al Menu > Product or Apphca[mn $Car[h > tlpphcaGon List > Application Detail
FL #
FL2894-R12
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer G.A.P. Roofing
Address/Phone/Email 4444 Hunt Street
pryor, OK 74361
(386)288-4583
dave.swaroopgap@gmail.com
Authorized Signature Dave Swaroop
dave.swaroopgap@grnail.com
Technical Representative Dave Swaroop
Address/Phone/Email P.O. Box 828
Jasper, FL 320S2
(386) 288-4583
dave.swaroopgap@gmaii.com
Quality Assurance Representative
Address/Rhone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2894 R12 COI GAP19001.3 2020 FBC Eval Underlayments final.p_of
Referenced Standard and Year (of Standard) Standard Year
ASTM D 226 2009
ASTM D 2626 2004
ASTM D 3909 2014
ASTM D 4601 2004
ASTM D 4869 2016
TA5 110 2000
https://Moridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDqukmQHM%2b9%2nMvn3fH%2fHUfpzA9bX3eUtOA3tyyx%2fRYMjUA%3d%3d 113
8/5/2021
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product A proval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary. of Products
Method 1 Option D
03/31/2021
04/04/2021
04/06/2021
06/08/2021
FL #
Model, Number or Name
Description
2894.1
#40 Organic Base Sheet
ASTM D 2626, organic roofing felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL2894 R12 II GAP19001.3 2020 FBC Eval Underlaym n
Approved for use outside HVHZ: Yes
final•p_d1
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: evaluation report for limits of use.
Evaluation Reports
lee
FL2894 R12 AE GAP19001.3 2020 FBC Eval Underlayments
final.rdfdf
Created by Independent Third Party: Yes
2894.2
30 ASTM 4869
ASTM D 4869, Type II organic roofing felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2894 R12 II GAP1900 ,3 2020 FBC Eval Underlayments
Approved for use outside HVHZ: Yes
final.gdf
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL2894 R12 AE GAP19001.3 2020 FBC Eva] Underlavments
final.rZQ
Created by Independent Third Party: Yes
2894.,
ASTM 15 D226 Felt
ASTM D 226, Type I organic roofing felt
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL2894 R12 II GAP19001.3 2020 FBC Eval Underlayments
fiaig pdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL2894 R12 AE GAP19001.3 2020 FBC Eva] Underlayments
ED&LQUfff
Created by Independent Third Party: Yes
2894.4
ASTM 30 D226 Felt
ASTM D 226, Type II organic roofing felt
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL2894 R12 II GAP19001.3 2020 FBC Eval Underlaym?,=
Approved for use outside HVHZ: Yes
final.2df
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL2894 R12 AE GAP19001.3 2020 FBC Eval Underlaymen
final.Rd
Created by Independent Third Party: Yes
2894.5
Fiberglass *90 Mineral Surface Roll
ASTM D 3909 roll roofing
Roofing
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2894 R12 II GAP19001.3 2020 FBC Eval Underlaymen
final.pQf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
https://floHdabuilding.org/pr/pr_app_dtl.aspx?param= GEVXQwtDqukmQHM%2b9°/a2tiMvn3fH%2fHUfpzAgbX3eUtOA3tyyx%2fRYMjUA%3d%3d 213
8/512021
Florida Building Code Online
Design Pressure: N/A
Other: See evaluation report for limits of use.
Evaluation Reports
F 2894 R12 AE GAPI 9001.3 2020 FBC Eva] UadgfkyMg=
final.gdf
Created by Independent Third Party: Yes
2894.E
Fiberglass Base Sheet G2
ASTM D 4601, Type II
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
F 2894 R12 II APS 001 3 2020 FBC Eval Undffkyments
final.gg[
Impact Resistant: N/A
Design Pressure: N/A
Other: S e evaluation report for limits of use.
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL2894 R12 AE GAP19001 3 2020 FBC Eval Upd2dayments
final.gff
Created by Independent Third Party: Yes
2894.7
Tile Underlayment
ASTM D 6380, Class M, Type II organic roofing felt
Limits of
Use
Installation Instructions
Approved
for use in HVHZ: Yes
FL894 R12 II GAP19001 3 2020 FBC Eval UndenlAyments
Approved
for use outside HVHZ: Yes
final.gAf
Impact I
tesistant: N/A
Verified By: Zachary R. Priest PE-74021
Design F
ressure: N/A
Created by Independent Third Party: Yes
Other: 5
e evaluation report for limits of use.
Evaluation Reports
FL894 R12 AE GAP19001 3 2020 FBC Eval Underlayments
fin LP.df
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850487-1824
The State of Florida is an AA/EEO employer. Coovnaht 2007-2013 State of Florida :: Pnyacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail acidness released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, ES., please click llsco-.
product Approval Accepts:
M ® Fin-1 -7--
Credit Card
Safe
hftps://floridabuilding.org/pr/pr_app_dll.aspx?param= GEVXCANtDqukmOHM%2b9%2fiMvn3fH%2fHUfpzAgbX3eUtDA3tyyx%2fRYMjUA%3d%3d 313
CREEK
TECHNICAL SERVICES. LLC
EVALUATION REPORT
Manufacturer:
Manufacturing Plants:
Quality Assurance:
SCOPE
G.A.P. ROOFING, INC.
4444 Hunt Street
Pryor, OK 74361
(800)880-9808
www.gaproofing.us
Pryor, OK
Registry No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, 7r" EDITION
Keystone Certifications ,Inc. (QUA1824)
Issued March 30. 2021
Category: Roofing
Subcategory: Underlayments
Code Edition: Florida Building Code, r Edition
(2020) including High -Velocity Hurricane Zones (HVHZ)
Code Sections: 1507.1.1. 1518.4, 1523.1.1
Properties: Physical properties
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
GAPF-005-02-02
ASTM D 4869
2016
PRI Construction Materials Technologies (TST5878)
GAPF-009-02-01
ASTM D 4601
2004(2012)El
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
GAPF-011-02-01
ASTM D 3909
2014
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
GAPR-026-0201A
ASTM D 1623
2017
PRI Construction Materials Technologies (TST5878)
GAPR-027-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST5878)
GAPR-031-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST5878)
1047T0010
ASTM D 1623
2017
PRI Construction Materials Technologies (TST5878)
104TT0039
ASTM D 2626
2004(2012)E1
GAP19001.3 FL2894-R12 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
.CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
G.A.P. ROOFING, INC
Underlayments
GAP ASTM 15 D226 Felt An ASTM D 226, Type I asphalt saturated organic felt underlayment For use in the
HVHZ only.
GAP ASTM 30 D226 Felt An ASTM D 226, Type II asphalt saturated organic felt underlayment.
GAP 30 ASTM 4869 An ASTM D 4869, Type II asphalt saturated organic felt underlayment. For use in
the non-HVHZ only.
GAP Fiberglass #90 An ASTM D 3909 asphalt roll roofing felt made from fiberglass mat that is coated on
Mineral Surface Roll both sides with weathering grade asphalt and surfaced with ceramic mineral state
Roofing granules. For use in the non-HVHZ only.
GAP Fiberglass Base An ASTM D 4601, Type II made from fiberglass mat that is coated on both sides
Sheet G2 with weathering grade asphalt and surfaced with white sand fines. For use in the
non-HVHZ only.
GAP Tile Underlayment An ASTM D 6380, Class M, Type II asphalt saturated organic felt undedayment
coated on both sides with weathering grade coating asphalt and covered with head
lap granules.
GAP #40 Organic Base An ASTM D 2626 undedayment constructed of asphalt -saturated felt that is coated
Sheet on both sides with weathering grade asphalt and surfaced with mineral surface
fines.
APPLICATION
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
Roof coverings shall be mechanically fastened through the undedayment to the roof deck except as noted below for
Tile Underlayment. #40 Organic Base Sheet may in used in adhered file applications when used as the base sheet in
a two-ply undedayment as permitted by code, and as approved in the cap sheet or the roofing product approval.
Underlayment
Asphalt
Shingles
Metal Roof
Panels and
Shingles
composits or
Photovoltaic
Shingles
Wood
Shingles and
Shakes
Slats
Shingles
Clay and
Concrete Tile
ASTM 15 D226 Felt
Y
Y
Y
Y°
Y
N
30 ASTM 4869
Y
Y
Y
Y
Y
N
ASTM 30 D226 Felt
Y
Y
Y
Y
Y
Y
Tile Underlayment
Yi
N
N
N
N
Yt
Fiberglass #90 Mineral Surface
Roll Rooen
Yr
N
N
N
N
N
F '91ass Base Sheet (32
N
N
N
N
N
N
#40 Organic Base Sheet
N
N
N
N
N
N
Nolen. 1) Open valley applications per 1507.2.9.2
2) wood shingles only
3) May, be used with mortar set tile and adhesive set file using any of the following in accordance with FBC:
- Dew TILE BOND Roof Tile Adhesive
-DAP Touch'n Seal Storm Bond 2 Two -Component Polyurethane Roof Tile Adhesive
4) Permitted to be used as the base sheet In a two-ply undedayment in accordance with FRSArrRI Frodda High Wind Concrete and Clay
Tile Installation Manual. Sixth Edition. RAS 118, RAS 119, or RAS 120
GAP19001.3
2 of
This evaluation report is provided for State of Florida product approval under Rule 61 UZD-3. 1 he manufacturer snail noury l:RttM1
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use. or other product attributes that are not
specifically addressed herein.
CREEK G.A.P. ROOFING, INC Unaertaymentsnta
TECHNICAL SERVICES. LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant Installation detail shall prevail.
4) Roof slope limitations shall be in accordance with FBC requirements.
5) Undedayments may be used as described in other current FBC product approval documents.
6) Undedayments without granule surfacing shall not be exposed on the roof deck for greater than 30 days.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7" Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
No 74021
ir
Qt STATE 09 '41
i'i n�•T� O R 1oY*e.::.
0 N A;
CERTIFICATION OF INDEPENDENCE
2021.03.30
15:15:56
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
GAP19001.3 FL2894-R12 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.