GAF Evaluation Report 01506.04.08-R19
1Campus Drive
Parsippany, NJ 07054
(800) 766-3411
FL10626-R19
Date of Issuance: 04/25/2008
Revision 19:10/19/2020
SCOPE:
This Evaluation Report is issued under'Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has.been reviewed. by.Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted
herein.
DEscFuvnON:- GAF Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any
changes to the .product(s), the Quality Assurance or the production facility location(s). NEW ETC,. LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvEitvsEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEM01etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
it
.g;�tc�ea+tv" z
The tatslmileseal appearing was authordedbyRobert
Nieminen; P.E. on.10/19/2020. This does not serve as an
` �J�m.,.c.• t° electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
1. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,.a financial. interest In any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen; P.E. does. not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This Is:a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
(02019 NEMO ETC, LLC
OMEMO I etc.
ROOFING COMPONENT EVALUATION:
1. .-
Product Category:
Roofing
Sub -Category:
Underlayment-
Compliance Statement: GAF Roof Under(ayments, as produced by GAF, have demonstrated compliance with the
following sections of the 7`" Edition (2020) Florida Building .Code through
testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
:Sections:: ..
Pro a := : ..
'Standard
.Year
1504:3.1
Wind resistance
FM 4474
2011
1507.1.1,1507.2.4; 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.1.1.1(2&3, Exception),
Tear Strength
ASTM D4533
2015
1507.1.1.1(5) / 11905.1.1.1(2&;3,
Exception ), :R905.1.1.1(5)
1507.1.1.1(2&3, Exception),
Tensile strength
ASTM D5035
2011
1507.1.1:1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5}
Liquid water transmission
ASTM D4869
2016
1507.1.1 / R905.1.1
Material standard
ASTM D6757
2016
1507.3.3, R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2
Material standard
ASTMD6164
2011
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Examination'
Reference
Date
ERD (TST6D49)
ASTM D1623 & FRSA/TRI (Slippage)
G34150.08.11
11/14/2011
ERD (TST 6049)
ASTM D6164 (GA)
640630.01.14-2B
01/07/2014
ERD (TST 5049)
ASTM D6164 (GA)
G46160.09.14-3A
09/09/2014
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-3
03/01/2017
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-4
09/01/2017
ERD (TST 6D49)
ASTM D1970 (GA)
GAF-SC13285.03.17-1
03/08/2017
Intertek (TST 1558)
ASTM D4869 (Dadra, India)
F8549.02-106-18
11/08/2016
NEMO (TST 6049)
Physical Properties (ON)
44-GAF-I9-SSMBB-03.A
OS/13/2019
PRI (TST 5878)
ASTM D1970 (IN)
GAF-324.02-01
11/30/2011
PRI (TST 5878)
ASTM D226 (OK)
GAF-339-02-01
03/13/2012
PRI (TST 5878)
ASTM D4798 (NC)
GAF-349-02-01
07/03/2012
PRI (TST 5878)
Wind Uplift
GAF-434-02-01
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434.02-03
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-04
09/16/2013
PRI (TST 5878)
ASTM D4533 (various)
GAF-818.02-01
12/05/2017
PRI (TST 5878)
ASTM D1970 (AL)'
MSA-047-02-01
04/11/2018
PRI.(TST 5878)
ASTM D4533 (LA)
GAF-826-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-847-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-914-02-01
04/10/2019
PRI (TST 5818)
ASTM D4533,05035(VA)
376T0012
07/15/2019
PRI (TST-5878)
ASTM D4533 (Umerkui Kilvani, India)
376TOO18
07/31/2019
PRI (TST 5878)
ASTM D4533 (Parni, India)
376T0018
07/31/2019
PRI (TST 5878)
ASTM D1970 (AR)
376T0032
10/22/2019
PRI (TST 5878)
ASTM D5035 (various)
376TO103
09/11/2020
UL (TST 1140)
ASTM D6757 (TX)
02NK22569
06/04/2002
UL (TST' 1740)
ASTM D6757 (NC)
1ONK11990
65/24/2012
NEMO ETC, U.C. Evaluation Report 01506.04.MR19
Certi/kore of Aurborltot;ph #32455 7- EDITION (2020) FBGNO•N-HVHZ EVALUATION FL10626-R19
GAF Roof Underlayments Revision 19:10/19/2020
Page 2-of 8
M
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
5.1
5.2
5.3
5.4
Entity . .
NEW ETC
UL, LLC (QUA 9625)
UL, LLC (QUA 9625)
UL,.LLC (QUA 9625)
Examination
Traceability
Quality Control
Quality Control
Quality Control
O.-NEm6letc.
Reference Date
FBC Cross: Listing 04/22/2020
Service Confirmation 09/29/2020
Service Confirmation (AL) OS/04/2020
Florida BCIS Current
PRODucT DESCRIPTION:
Product ::' .
:; ':=Material.Standard:::'
Liberty'" SB.S Self -Adhering Base/Ply
ASTM D1970
Sheet
Savannah, GA
StormGuard" Film Surfaced Leak Barrier
ASTM D1970
Mt. Vernon; IN
Savannah, GA
Arkadelphia, AR
WeatherWatchm Mineral Surfaced Leak
ASTM D1970
Mt. Vernon, IN
Barrier
Savannah, GA
Tuscaloosa, AL
Deck -Armor'" Premium Breathable Roof
1507.1.1.1(2&3, inception) /
Dadra, India
Deck Protection
R905.1.1.1(2&3, Exception)
1507.1.1.1(2&3, Exception),.
Dadra, India
FeltBuster® High -Traction Synthetic
1507.1.1.1(5) / R905.1.1.1(2&3,
Richmond, VA
Roofing Felt.
Exception), 11905.1.1:1(5)
Spartanburg; SC
Shingle -Mate° Roof Deck Protection,
ASTM D226, Type II (Table 1)
Pryor, OK
StormSaf6l Anchor Sheet
1507.1.1.1(2&3, Exception)/
North Bay, ON
11905.1.1.1(20, Exception)
1507.1.1.1(2&3, Exception) /
Dadra, India
Tiger PawTM Roof Deck Protection
11905.1.1.1(20, Exception)
Parzai, India
Umerkui Kilvani, India
RoofPro"' SBS-Modified All -Purpose
AC165
Fontana, CA
Underlayment
VersaShield® Fire -Resistant Roof Deck
ASTM D6757
Conover, NC
Protection
Ruberold® Mop Granule
ASTM D6164
Savannah, GA
FRSA/TRI 09-18
Ruberold° Mop Granule FIR
ARM D6164
Savannah, GA
FRSA/TRI:0948
This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade
Counties).
This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction,
This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Referto FBC2603 for requirements and limitations concerning
the use of foam plastic insulation.
NEW ETC, LLC Evaluation Report 0106.04.08=R19
Certificate 0/Authorlsat;00 i1324SS 7m EDITION (20.20), FBC NON-HVHZ EVALUATION FU0626-R 19
GAF Roof Undertayments Revision 19:10/19/2020
Page 3 of 8
NNEM'0-jetc.
5.5 GAF Roof Underlaym.ents may be used with any prepared roof cover where the product, is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt..
-Clay and Concrete Tile
::.
Metal:.::
Slate or .
Wood
Underlayment
shingles.
0507.3j: ;
Slate Type
.
Mechanical
Adhesive-
Panels
Shingies
.. Shingles,
Shakes
ltso> 2J
Shingles :
Attath
Set
(107.4)
(1507 s)
(1507.7)
(uozs) ::
: (107.9)
Yes
Yes
Elbert - SBS Self -Adhering
y g
Yes
No
No
No
No
No
)jain:strip5.
GoiMstrips,
Base/Ply Sheet
s507.1.1.3 /
1507.1.1.3 /
R90s.1.1.3)
R905.1.1.3)
Yes
Yes
StormGuard® Film Surfaced Leak
Yes
No
No
Yes
Yes
Yes
i507i
Barrier
3%
1507.L' /
R905:1.1.3)
R90S.1.1.3)
Yes
Yes
WeatherWatche Mineral Surfaced
Yes
No
No
No
No
No
Uontstnps,
Gaird strips,
Leak Barrier
1507.1_1.3/
1507.1.1.3/
11905.1.1.3)
1190S.1.1.3)
Deck -Armor— Premium Breathable
Roof Deck Protection
Yes
No
No
Yes
Yes
Yes
No
No
FeltBuster® High Traction
Synthetic Roofing Felt
Yes
No
No
No
No
No
No
No
Shingle -Mate" Roof Deck
Protection
Yes
No
No
No
No
No
No
No
Tiger Paw— Roof Deck ProtectionFNo
No
No
Yes
Yes
Yes
No
No
RootPrO"' 5B5-Modlfled AI!
Purpose Underlayment
No
No
No
No
Yes
Yes
Yes
VersaShield® Fire -Resistant Roof
No
No
Na
No
No
No
No
Deck Protection
Yes
Yes
RuberoidsMop Granule
(Cap Sheet to
heet In
hPSystem)
No
NO
No
No
No
2-ply system)
2-ply system)
Sec 5.6:1
Yes
Yes
Ruberbid® MopGranule FR
heet In
PSystem)(CapSheetin
No
No
No
No
No
2-pty system)
Ply system)
See. 5.6.1
5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations.
TABLE 1A:_ALLCIWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINAilONIP
Underlayment..
Adhesive.
Florida:Product Approval
Ruberold® Mop Granule; Niberoidm Mop Granule FIR
Dupont "file Bond'" Roof Tile Adhesive"
FL22525
Refer to file Manufacturer's or Adhesive Manufacturer's Florida Product Approval far Overturning .Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 01506.04.08-R19
Certificate of AUfhoifzorfpe s32455 7-EDITION (2020) FBC:NON-HVH2 EVALUATION F1.10626-1119
GAF Roof Underlayments Revision 19:10/19/2020
Page 4 of 8
NNEMOJetc.
5.7 Allowable Substrates:
TABLE 2: 'SUBSTRATE OPTIONS FOR ADN6REb UNDERLAYMENTS
Underlayrttent:::
Application_,.Substrates
Liberty" SBS Self -Adhering Base/Ply Sheet
self -adhering
(Optional)
ASTM D41
plywood
StormGuard° Film.Surfaced Leak Barrier
Weather.Watch° Mineral Surfaced Leak Barrier
Liberty"" SBS Self -Adhering Base/Ply Sheet
self -adhering.
None
ASTM D226 felt, Type II
StormGuard• Film Surfaced Leak Barrier
Weather Watcho Mineral Surfaced Leak Barrier
Liberty"" SBS Self -Adhering Base/Ply Sheet
self -adhering
ASTM D41
metal (flashing metal; valley metal, etc.)
StormGuard° Film Surfaced teak Barrier
Weather Watch°' Mineral Surfaced Leak Barrier
Ruberoidg Mop Granule
hot asphalt
ASTM D41
structural concrete
Ruberoid® Mop Granule FR
Ruberoid® Mop Granule
hot asphalt
None
GAFGLAS ID #80 UltimaTM Base Sheet or
Ruberoid® 20 Smooth
®
Ruberoid Mop Granule FR
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached. NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions,
_hut — for mechanically attached base sheets - not less than:
FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table
1(forTwo-P1yAsphalt Applied Hot Mop Underlayment)
or
0 Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underiayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is
the result of testing for wind load resistance based on allowable windloads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
S.8:3.1 Direct -to -Deck: r
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical
(highest) design pressure determined in.accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum. Design Pressure = -442.5 psf.
Deck: Min. 2,500:psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS #7S Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4,
Tel -Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to
25 Ibs/square.:
Cap Sheet: Ruberoid° Mop Granule or Ruberoid° Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25:Ibs/square.
MEMO ETC, LLC Evaluation Report 01506.04.08+R19
CertifiroteofAuthoriratAM #324SS 7-EDITION (2020) FBC NON-HVH2 EVALUATION. FL10626-Rig
GAF Roof Underlayments Revlslon 19:10/19/202.0
Page 5of8
ONEMOletc.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical
(highest).design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or.exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated. pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
#2 Maximum Design Pressure =-45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.
1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the
min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows in the field
of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure = -75 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'"° Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.
1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the
min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows in the
field of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure = -97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga., min.
1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the
min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the
sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
5.9 Exposure Limitations:
TABLE 3:' EXPOSURE (:IMITATIONS
tJnderlaymerit
Prepared Roof Cover
Maximum
Installation Type
Exposure (days)
Deck -Armor`"' Premium Breathable Roof Deck Protection, FeltBuster® High -Traction
Synthetic Roofing Felt, Shingle -Mate® Roof Deck Protection, StormSafe'' Anchor
Sheet, Tiger Paw"" Roof Deck Protection, RoofPro`"" SBS-Modified All -Purpose
Mechanically attached
30
Underlayment, VersaShield® Fire -Resistant Roof Deck Protection, Liberty'" SBS Self -
Adhering Base/Ply Sheet, StormGuard® Film Surfaced Leak Barrier and
WeatherWatch® Mineral Surfaced Leak Barrier
Adhesive -set tile roof system
180
Ruberoid® Mop Granule and Ruberoid® Mop Granule FR
Mechanically attached
UNLIMITED
NEW ETC, LLC Evaluation Report 01506.04.08-R19
Certificate of Authorization #32455 7 H EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-1119
GAF Roof Underlayments Revision 19: 10/19/2020
Page 6 of 8
to-Wmoletc..
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct=deck tile roof assemblies, the
maximum roof slope .shall be as follows. These slope limitations can only be exceeded. by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS
FOR D'IREMDECKTILE INSTALLATIONS-
Underlayment;. "
Tire Profile.
Staging Method'
Maximurh Staging 51ope
Ruberoidm Mop Granule
Flat
Max- 10-tile stack
4:12
Flat
Max. 6-tile stack (4 over 2)
5:12
Lugged .
Max.10-tile stack
5:12
Ruberofd®Mop Granule FR
Flat or Lugged
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max.10-tile stack
4:12
6. INSTALLATION:
6.1 GAF Roof Underlaymentsshall be installed in accordance with GAF published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application and prime the substrate (if applicable).
0.4 Deck Armor " Premium-Rreathable Roof Deck Protection or. -Tiger Paw"" Roof, Deck Protection:
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or
1507.1.1.1(3, Exception): or FBC Residential R905.1,1.1(2, Exception), or R905.1.1.1(3, Exception) for the type of
prepared roof covering to be installed, and the manufacturer's installation instructions, FBC requirements take
precedence over the manufacturer's installation instructions..
6.4 FeltEl stere High Traction SyothetieRoofing Felt:
6.4.1 Shall be installed in compliance with requirements for a synthetic. underlayment in FBC 1507.1:1.1(2, Exception),
1507.1.1.1(3,_Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or
R905.1.1.1(5)forthetype of prepared roof coveringto be installed, and the manufacturer's installation instructions.
FBC requirements take precedence over the manufacturer's installation instructions.
6:5 StormS&6-Anehor'Sheet:
6.5.1 StormSafeTm Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply undedayment systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayrent in FBC 1507.1.1.1(2, Exception) or
1507.1:1.1(3, Exception) or FBC Residential R905.1:1.1(2, Exception) or 11905.1.1.10, Exception) for the type of
prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.5.3 One the same day, install Liberty m SBS Self -Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or
WeatherWatch® Mineral Surfaced Leak Barrier over the StormSafeT" Anchor Sheet.
6:6 RadfPro— SBS=Modified All -Purpose Underlayment andShingle-MeteP Roof Deck Arotection!
6.6.1 Shall be installed in compliance with requirements for an approved. mechanically attached underlayment (ASTM
D226, Type.11) In FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the`type:of prepared roof covering to
be Installed, and the manufacturer's installation Instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
MEMO ETC, LLC Evaluation Report 01506.04.08=1119
Certificate of Authorization #324SS 7tH EDITI ON (2020) FBGNON-HVHZ EVALUATION FL10626-R19
GAF Roof Underlayments Revision 19:10/19/2020
Page 7 of 8