HomeMy WebLinkAboutEvaluation Report REV. 8-4-21ENGINEER
COO
EVALUATE
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
TEST CONSULT
GAF Evaluation Report 01506.01.08-1133
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
SCOPE:
f91KIMIdGMt
Date of Issuance: 01/03/2008
Revision 33: 08/04/2021
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7' Edition (2020) Florida Building Code sections noted herein.
D�SCRIP,TION: GAF As halt.Roo S�hitn tes for Gseiiri�FB:C,nc>n HNHZi'�irH.— actions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded bythe words "NEMO Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
V..' • 'ice
Robert J.M. Nieminen, P.E. 'y.' The facsimile seal appearing was authorized by Robert
`'.;fiF F=^;-,`•
,Sgi•• l�s.�.� Nieminen, P.E. on 08/04/2021. This does not serve as an
Florida Registration No. 59166, Florida DCA ANE1983 �',✓�• �i "' electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018 NEMO ETC, LLC
a
v
i
ONEMO I etc.
ROOFING SYSTEMS EVALUATION:
Product Category:
Roofing
Sub -Category:
Asphalt Shingles
Compliance Statement:
GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the
71h Edition (2020) Florida Building
Code through testing in accordance with the following
Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
IN I
Section
Pro a
Standard
'Year ,
1507.2.4, R905.2.3
Material standard
ASTM D1970
2015
1507.2.5, R905.2.4
Material standard
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM' D7158
2019
1507.2.7.1, R905.2.6.1
Wind Resistance
TAS 107
2020
Enti
Examination
Reference
Date
PRI (TST 5878)
Physical Properties
GAF-025-02-01
03/27/2002
PRI (TST 5878)
ASTM D3462
GAF-059-02-01
09/02/2004
PRI (TST 5878)
ASTM D3462
GAF-080-02-01
05/25/2005
PRI (TST 5878)
Physical Properties
GAF-324-02-01
12/01/2011
PRI (TST 5878)
ASTM D1970 (QuickStart)
GAF-340-02-01
03/13/2012
PRI (TST 5878)
ASTM D3462
GAF-897-02-01
11/08/2018
PRI (TST 5878)
ASTM D3462
GAF-898-02-01
11/08/2018
PRI (TST 5878)
ASTM D3462
GAF-899-02-01
11/15/2018
PRI (TST 5878)
ASTM D3462 (IN-MV)
376TO133
02/05/2021
PRI (TST 5878)
ASTM D3462 (CA-S)
376TO135
02/05/2021
PRI (TST 5878)
ASTM D3462 (IN-MV)
376TO163
04/20/2021
UL(TST 1740)
ASTM D3462
93NK6295
11/29/1993
UL(TST 1740)
ASTM D3462
99NK43835
01/12/2000
UL (TST 1740)
TAS 107
94NK9632
03/29/2000
UL(TST 1740)
ASTM D3462
01NK06632
02/02/2001
UL (TST 1740)
ASTM D3161, TAS 107
01NK9226
05/21/2001
UL(TST 1740)
ASTM D3161
01NK37122
12/18/2001
UL (TST 1740)
ASTM D3462
01NK37122
12/19/2001
UL (TST 1740)
ASTM D3161, TAS 107
02NK12980
04/10/2002
UL (TST 1740)
ASTM D3161, TAS 107
02NK30871
09/09/2002
UL(TST 1740)
ASTM D3161
03CA5367
03/11/2003
UL (TST 1740)
ASTM D3462
03NK26444
10/17/2003
UL (TST 1740)
ASTM D3462
04NK13850
06/07/2004
UL (TST 1740)
ASTM D3161
04NK13850
06/23/2004
UL(TST 1740)
ASTM D3161
04NK30546
03/10/2005
UL (TST 1740)
ASTM D3462
04NK22009
05/06/2005
UL(TST 1740)
ASTM D3161
04NK22009
05/09/2005
UL (TST 1740)
ASTM D3462
05NK27924
02/10/2006
UL (TST 1740)
ASTM D3161
OSNK27924
02/11/2006
UL (TST 1740)
ASTM D3161,D3462
06CA18077
06/05/2006
UL (TST 1740)
ASTM D3161,D3462
06CA18074
06/16/2006
UL(TST 1740)
ASTM D3161,D3462
06CA35251
10/18/2006
UL (TST 1740)
ASTM D3462
06CA31603
12/01/2006
UL (TST 1740)
ASTM D3161, D3462
06CA41095
12/27/2006
UL (TST 1740)
ASTM D3161
07NK05228
03/13/2007
UL(TST 1740)
ASTM D3161
06CA31611
04/04/2007
UL(TST 1740)
ASTM D3161
06CA61148
04/09/2007
MEMO ETC, LLC Evaluation Report 01506.01.08-1133
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R31
GAF Asphalt Roof Shingles Revision 33: 08/04/2021
Page 2 of 8
ONEMO I etc.
Kngty
Examination
Reference
Date
UL (TST 1740)
ASTM D3161, D3462
07CA31742
11/08/2007
UL (TST 1740)
ASTM D3161, D7158, D3462
08CA06100
03/13/2008
UL (TST 1740)
ASTM D3161,D3462
07CA55908
04/01/2008
UL (TST 1740)
ASTM D3161,D3462
09CA10592
03/26/2009
UL (TST 1740)
ASTM D3161,D3462
09CA06856
05/15/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
09NK06647
08/01/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
09CA27281
08/27/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
IOCA35554
03/05/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
IOCA13686
05/15/2010
UL (TST 1740)
ASTM D3462
IOCA07264
05/27/2010
UL(TST 1740)
ASTM D3462
IOCA11953
10/29/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
1ONK11951
10/30/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
1ONK12070
11/04/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
08CA06100
01/30/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
10CA53934
03/31/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA48924
10/22/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA47919
12/03/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA48408
12/08/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA48725
12/09/2011
UL, I.I.C. (TST 9628)
ASTM D3462
12CA34891
10/12/2012
UL, U.C. (TST 9628)
ASTM D3161, D7158, D3462
12CA58151
02/15/2013
UL, I.I.C. (TST 9628)
ASTM D3161
12CA38083
02/26/2013
UL, I.I.C. (TST 9628)
ASTM D3161
13CA32332
06/18/2013
UL, U.C. (TST 9628)
ASTM D3161
13CA37934
08/02/2013
UL, U.C. (TST 9628)
ASTM D3161, D7158, D3462
4786875675
07/17/2015
UL, U.C. (TST 9628)
ASTM D3161, D7158, D3462
4787434542
05/17/2016
UL, LLC. (TST 9628)
ASTM D3161, D7158, D3462
4788717529
09/09/2016
UL, LLC. (TST 9628)
ASTM D3161
4788698165
11/09/2018
UL, LLC. (TST 9628)
ASTM D3161
4788669132
12/13/2018
UL, I.I.C. (TST 9628)
ASTM D3161
4788891098
02/14/2019
UL, I.I.C. (TST 9628)
ASTM D3161, D7158, D3462
4788932264
08/16/2019
UL, I.I.C. (TST 9628)
ASTM D3161, D7158, D3462
4789115488
08/16/2019
UL, LLC. (TST 9628)
ASTM D3161, D7158, D3462
4789115488
10/03/2019
UL, U.C. (TST 9628)
ASTM D3161
4788959558
10/17/2019
UL, U.C. (TST 9628)
ASTM D3161, D7158, D3462
4786508528
11/01/2019
UL, LLC. (TST 9628)
ASTM D3161
4789132672
10/27/2020
UL, LLC. (TST 9628)
ASTM D3161
4789732437
04/15/2021
UL, U.C. (QUA 9625)
Quality Control
Service Confirmation
10/18/2018
UL, LLC. (QUA 9625)
Quality Control
Florida BCIS
Current
4 TABU
ASPHALT SHINGLE, COMPONENTS. `
Material
Type
Product
Description
Standard
Plant(s)
Pro -Start® Starter Strip Shingles
(fka, Pro -Start® Eave/Rake Starter
starter strips for asphalt roof shingles
ASTM D3462
CA-S, IN-MV, TX-D
Accessory
Strip Shingles)
Starter
mineral -surfaced, fiberglass -reinforced, self -
Strips
QuickStart® Peel & Stick Starter
adhering SBS modified bitumen starter strip,
nominal 9-inch x 33 ft roll, for use with
ASTM D1970
CA-S, IN-MV
Roll
asphalt shingles with exposure of 6-inch or
less
MEMO ETC, LLC Evaluation Report 01506.01.08-R33
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R31
GAF Asphalt Roof Shingles Revision 33: 09/04/2021
Page 3 of 8
U
ONEMOjetc.
`TABLET: ASPHALT SHINGLE COMPONENTS ,
Type
Product
Description
Material,
Standard
Plants)
color -coordinated starter strips for use with
Accessory
StarterMatch® Starter Strip
Shingles
Grand Canyon® and Grand Sequoia® series
asphalt shingles. StarterMatch are installed
as the second starter for Grand Canyon® and
ASTM D3462
CA-F
Starter
Grand Sequoia® series installations
Strips
WeatherBlockerTM Premium
Starter Strip Shingles (fka,
WeatherBlockerTM Premium
starter strips for asphalt roof shingles
ASTM D3462
IN-MV
Eave/Rake Starter Strip Shingles)
Marquis WeatherMax®
IN-MV
Royal Sovereign®
AL, CA-F, FL, GA, IN -
MV, PA, TX-D
fiberglass reinforced 3-tab asphalt roof
shingles
ASTM D3462
Sentinel®
GA, IN-MV, TX-D
Camelot® II
IN-MV
Fortitude®
PA
Glenwood®
IN-MV
Grand Canyon®
CA-F, IN-MV
Grand Sequoia®
CA-F, IN-MV
Grand Sequoia® IR
CA-F, IN-MV
Grand Sequoia® ArmorShield®
CA-F
Grand Sequoia® AS
CA-F
Timberline® American Harvest®
AL, CA-F, IN -MC, PA
Timberline® AH
AL, CA-F, IN -MC, PA
Timberline® ArmorShield® II
TX-E
Timberline® AS II
TX-E
Timberline® Cool Series
CA-F
Asphalt
Timberline® CS
CA-F
Shingles
fiberglass reinforced, laminated asphalt
roof shingles
ASTM D3462
Timberline HD®
AL, CA-S, CA-F, FL, IN -
MC, MD, MN, PA, TX-
D, TX-E
AL, CA-F, CA-S, FL, IN -
Timberline® HDZTM
MC, MD, MN, PA, TX-
D, TX-E
Timberline® Natural Shadow®
AL, CA-S, IN -MC, MD,
MN,.PA, TX-D, TX-E
AL, CA-S, FL, IN -MC,
Timberline® NS
MD, MN, PA, TX-D, TX-
E
Timberline Ultra HD®
AL, CA-S, IN -MC, MN,
PA, TX-E
Timberline® UHD
AL, CA-S, IN -MC, MN,
PA, TX-E
Woodland®
IN-MV
Slateline—
fiberglass reinforced 5-tab asphalt roof
shingle
ASTM D3462
IN-MV
Seal -A -Ridge® ArmorShield®
GA
Seal -A -Ridge® AS
GA
Hip &
Ridge
Shingles
fiberglass reinforced, hip and ridge
asphalt roof shingles
ASTM D3462
Seal -A -Ridge® Ridge Cap Shingles
GA, IN-MV
Timbertex® Premium Ridge Cap
Shingles
IN-MV
NEMO ETC, LLC
Certificate ojAuthorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION
GAF Asphalt Roof Shingles
Evaluation Report 01506.01.08-R33
F1.101241131
Revision 33: 08/04/2021
Page 4 of 8
ONEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
TABLEZA WIND CLASSIFICATIdNSr ASPF(ALT SHINGLES
Product
FBC Table 1507.2.9:1 or.R905.2.6.1
Marquis WeatherMax®
ASTM D3161(F) & ASTM D7158(H)
Royal Sovereign®
ASTM D3161(F) & ASTM D7158(H)
Sentinel®
ASTM D3161(F) & ASTM D7158(H)
Camelot® II
ASTM D3161(F) & ASTM D7158(H)
Fortitude®
ASTM D3161(F) & ASTM D7158(H)
Glenwood®
ASTM D3161(F) & ASTM D7158(H)
Grand Canyon®
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia®
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia® IR
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia® ArmorShield®
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia® AS
ASTM D3161(F) & ASTM D7158(H)
Timberline® American Harvest®
ASTM D3161(F) & ASTM D7158(H)
Timberline® AH
ASTM D3161(F) & ASTM D7158(H)
Timberline® ArmorShield® II
ASTM D3161(F) & ASTM D7158(H)
Timberline® AS 11
ASTM D3161(F) & ASTM D7158(H)
Timberline® Cool Series
ASTM D3161(F) & ASTM D7158(H)
Timberline® CS
ASTM D3161(F) & ASTM D7158(H)
Timberline HD®
ASTM D3161(F) & ASTM D7158(H)
Timberline® HDZ''
ASTM D3161(F) & ASTM D7158(H)
Timberline® Natural Shadow®
ASTM D3161(F) & ASTM D7158(H)
Timberline® NS
ASTM D3161(F) & ASTM D7158(H)
Timberline Ultra HD®
ASTM D3161(F) & ASTM D7158(H)
Timberline® UHD
ASTM D3161(F) & ASTM D7158(H)
Woodland®
ASTM D3161(F) & ASTM D7158(H)
Slateline-
ASTM D3161(F) & ASTM D7158(H)
5.5.1 Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
MEMO ETC, LLC Evaluation Report 01506.01.08-1133
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R31
GAF Asphalt Roof Shingles Revision 33: 08/04/2021
Page 5 of 8
ON EMO I etc.
~; TABLE 2B WIND',CLASSIFICATIONS,,STARTER STRIPS AND.HIP;&`RIDGE.
Type
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake
ASTM D3161, Class F
Starter Strip Shingles)
Starter Strips
WeatherBlocker l Premium Starter Strip Shingles (fka,
ASTM D3161, Class F
WeatherBlocker— Premium Eave/Rake Starter Strip Shingles)
Seal -A -Ridge® ArmorShield®
ASTM D3161, Class F
Seal -A -Ridge® AS
ASTM D3161, Class F
Hip &Ridge
Shingles
Seal -A -Ridge® Ridge Cap Shingles
ASTM D3161, Class F
Timbertex® Premium Ridge Cap Shingles
ASTM D3161, Class F (sealant
required, See Section 6)
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
%6. 1N'STICLLATIQN
s
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally
Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.1.4 GAF asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations
set forth in FBC Section 1511 or R908 and GAF published installation instructions.
6:2' STARTER SHINGIES OR'STARTER<STRIP
6.2.1 Installation of Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake Starter Strip Shingles), WeatherBlocker'"
Premium Starter Strip Shingles (fka, WeatherBlocker'" Premium Eave/Rake Starter Strip Shingles) and QuickStart®
Peel & Stick Starter Roll shall comply with the GAF current published instructions.
6 3� ASPHALT SHINGLES
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4)
nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Camelot® II, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield®, and
Woodland® require minimum five (5) nails per shingle.
➢ SlatelineTM requires minimum six (6) nails per shingle.
NEMO ETC, LLC Evaluation Report 01506.01.08-1133
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R31
GAF Asphalt Roof Shingles Revision 33: 08/04/2021
Page 6 of 8
OMEMO I etc.
6.3.2 Fastening for Fortitude®. Timberline® AH. Timberline® CS and Timberline® HDZT": slopes 2:12 uD to 21:12
(iin)
I i-5,r - 14-5.B" (295mm - 372mm) 11-W- 14-W (295mm - 372mm)
VP-2-i{2' (13mm - 64mm) 12' - Z-1/T (13mm - G4mm)
14" 13-1w TARGET fdAIL ZONE
f33Tm.^.i) .... .... ....... .. .
— ---- — T ZONA OBJETIVO DE CLAVADO
6 718" — _�-- — 5-13/16- -7-5/8' (148n1m-194mm)
F6 ram)F1 I
STANDARD NAILING PATTERN:
Nail shingles approximately 6 7!8" (174 mrn) frorn bottom of shingle, in nailing area, as shown. Nails must not be exposed. Not for use on
Mansard roofs (21:12 slope and above).
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the GAF for details.
Fastening for Fortitude®. Timberline® AH. Timberline® CS and Timberline® HDZTM: slopes greater than 21:12
:Flip.'& RIDGE{SkWSLESC -
6.4.1 Installation of Seal -A -Ridge® Ridge Cap Shingles
shall comply with the GAF current published
instructions with a minimum two (2) nails,
minimum 3/8-inch head diameter located 6-7/8-
inch back from the exposed end and 0.5-inch ,�inmY �� �— Nail
from the edge. Clavo
NEMO ETC, LLC Evaluation Report 01506.01.08-R33
Certificate of Authorization N32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R31
GAF Asphalt Roof Shingles Revision 33: 08/04/2021
Page 7 of 8
6.4.2 Installation of Seal -A -Ridge® ArmorShield® and
Seal -A -Ridge® AS shall comply with the GAF
current published instructions with a minimum
two (2) nails, minimum 3/8-inch head diameter,
per shingle located 5.25-inch back from the
exposed end and 1-inch from the edge.
6.4.3 Installation of Timbertex® Premium Ridge Cap
Shingles shall comply with GAF current
published instructions with a minimum two (2)
nails, minimum 3/8-inch head diameter, per
shingle and beads of Henkel "Loctite PL Roof &
Flashing Polyurethane Sealant".
ONEMOjetc.
11.5° Sealant
1" (292 mm)u 1" Seliante
(25 MM) (I25 mm) Enduit d'otanchoitd
k r --1
t
Nail
Clavo 12"
Clover (305 corn)
9"
(229 mm)
12"
(305 mm)
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL LLC — QUA9625; (613) 371-2765; Jacob.Stewart@ul.com
- END OF EVALUATION REPORT -
MEMO ETC, LLC Evaluation Report 01506.01.08-R33
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R31
GAF Asphalt Roof Shingles Revision 33: 08/04/2021
Page 8 of 8