CONCRETE PLACEMENT
INSPECTION REPORT
DATE _ Wednesday February 2 2022
WEATHER
TEMPERATURE
WIND
HUMIDITY
S I M I 7 W TH F S
DAY x
BRIGHT SUN
CLEAR
OVERCAST
RAIN
x
BELOW 60
60-75
75-90
ABOVE 90
x
LOW
MODERATE
HIGH
Repat No
x
LOW
MODERATE
HIGH
17
x
INSPECTED: Concrete placement monitoring / North building second level columns (16) and elevator shaft
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS
AND ACCEPTED PRACTICES.
COMPLIES
YES NO N/A
x
1 SPARE VIBRATOR ON HAND
x
2 FORMS WETTED/OILED
x
3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW)
x
4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW)
x
5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAYS POUR
x
6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME
x
7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET
x
8 SUFFICIENT VIBRATION PERFORMED
x
9 STEEL REMAINED IN PLACE DURING POUR
x
10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS
Disposition of Inspection
Rx Section / Area Observed Re -Inspection
Work In Progress BRe-Inspection Required
COMMENTS/ACTION REQUIRED: Slump taken( first truck) at 7.5 ",the same truck ticket shows loading tirp€' Z,37.PM and it
at 4:37 PM ,or 30 minutes over the time limit. Both