HomeMy WebLinkAboutbddb89.pdfDuct Leakage Test Report Prescriptive or Performance (Method Permit # Job information Builder: DR HORTON Community: CREEKSIDE Lot: 89 Address: 3332 HOMESTEAD DRIVE Unit: city: FORT PIERCE State: FL zip: 34945 Duct Leakage Test Results R(Presciptive Method 0 Performance Method System 1 cfm25 (�►prescriptive Method cfm25 (total) System 2 To qualify as "substantially leak free" Qn must be less than or equal to 0.04 cfm25 if air handler unit is installed. If air handler unit is not installed, Qn Total System 3 must be less than or equal to 0.03. This testing method meets the cfm25 requirements in accordance with Section R403.2.2 Sum of any additional of all systems O Performance Method cfm25 (put or Total) cfm25 To qualify as "substantially leak free" Qn must not be greater than the proposed duct leakage Qn specified on Form R405-2014 50 - 1768 = 0.02 Qn Total of all systems PASS Total Conditioned Square Footage FAIL Leakage Type selected Qn specified on Form on Form R405-2014 R405-2014 (Enemy Calc) (Energy Calc) Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 1 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date ofTest: 01/20/2022 Signature of Tester: Printed Name of Tester: DANIEL MURPHY License/Certification # 5066440 Issuing Authority BPI Envelope Leakage Test Report (Blower Door Test) R405.4.2.1 Compliance Permit # Job Information Builder: DR HORTON Community: CREEKSIDE Lot: 89 Address: 3332 HOMESTEAD DRIVE Unit: City: FORT PIERCE State: FL Zip: 34945 Air Leakage Test Results Passing results must be 7 ACH(SO) or less 1310 x 60 : 14381.6 = 5.4 Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans [ode software calculated 1 ✓ PASS FAIL O Field measured and calculated r i When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. l � Certification of Test Results R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of of the buildi Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 l hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected jcompiiance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 01 /20/2022 Signature of Tester: j � r Printed Name of Tester: DANIEL MURPHY License/Certification # 5066440 Issuing Authority BPI