Loading...
HomeMy WebLinkAboutHealth Department Septic Permit APPLICATION 592559 ✓ STATE OF FLORIDA PERMIT #.56-SF-2182977 DEPARTMENT OF HEALTH DOCUMENT #:F11784834 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM '.� CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID,10/05/2020 we FEE PAID.:545.00 RECEIPT #:56-P1D-4743782 APPLICANT: Charlotte Stahlberg AGENT: Charlotte Stahlberg PROPERTY ADDRESS: 1310 Copenhaver Rd Fort Pierce, FL 34945. LOT: BLOCK: SUBDIVISION: ID#: 2313-123-0003-000.6 CHECKED [41 ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED: TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090:00 [21 483.00 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [28] DITCHES FT. [ ] 1031 OUTLET DEVICE [ j [291 PRIVATE WELLS FT [ ] 043 MULTI-CHAMBERED [ Y N ] ( ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [31] IRRIGATION WELLS FT [061 LEGEND 1. 70-143-11DC4 2. 70-143-54SC4 ( ] [121 POTABLE WATER 75 FT [ ] (071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 7.5 FT [ ] [08] LEVEL [ ] (341 PROPERTY LINES 100 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] 1101 AREA [1] 384 [2] SQFT [ ] [361 DRAINFIELD COVER j ] [111 DISTRIBUTION BOX HEADER X j ] [37] SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1.. 4.00 2. [ ] [38] SLOPES [ ] 1131 DRAINLINE SEPARATION [ ] [39] STABILIZATION 02/09/2022 [ ] [14] DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 5.00 [ ] [40] UNOBSTRUCTED AREA [ ] (17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS 1.00 [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [471 CONTRACTOR Jeff Nelson(Jeffrey Nelson Se [ ] [23] FILL TEXTURE [ ] [A8] OTHER INFILTRATOR Qulck4 E036(Single c [ ] 1241 EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED S FILLED Comments: Comments are on page 2. CONSTRUCTION I APPROVED / St.LUcle CED DATE: 12/21/2021 DISAPPROVED nvironmental Specials S- nyi(FI Department of He FINAL SYSTEM [ APPROVED DISAPPROVE St: ucle CHD DATE: 02/09/2022 nvironmental(Explanation of Violations on following page) Sp ciall t 11 NIT MonteoD a D artment of He DR 4016, 08/09 (ObsoleteS all previous editions which may not be use Incorporated: 64E-6-.003r FAC Page 2. of 3 EH Database v 1.0.1 AP1582559 EID2182977 r APPLIcATIoN #:AP1582559 STATE OF FLORIDA PERMIT #:56-SF-2182977 ' DEPARTMENT OF HEALTH . ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:Fi1784834 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:10/05/2020 WE FEE PAID:545.00 RECEIPT #:56-P1D-4743782 Violation Number Comment Comments The systern is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of 300 gpd. New ST,DT,Liberty 1/3 hp pump,and 4x8 long TRENCH DF installed. No violations,system ok to cover. Contractor notified by phone. Needs final inspection for alarm/pump function,verify that pump wires exit DT in conduit through the riser wall,gutters, mound system,depth of cover,and final site grading. 2/9/2022-Final inspection completed.Mound system checked,verified wires.ran through conduit-,and final site grading completed.Copy emailed to contractor and building department. DH 4016, 0.6/09 (obsoletes all previous editions which may not be used) Incorporated: 69E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1582559 EID2182977