Loading...
HomeMy WebLinkAboutBoat Lift SpecsIMM Quality Boat Lifts 4 POST BOAT LIFTS WITH 2 CRADLE BEAMS AND 4 CABLES "r PLATINUM BOAT LIFT SPECIFICATIONS ALL SPACING TO CENTER OF PILING LIFT CAPACITY A B C RECOMMENDED Min. PILE SIZE 4,500 Ibs. 132' 120" 178' 8" DIA. 7,000 Ibs. 144' 144" 204" 8" DIA. 10,000 Ibs. 144" 150" 208" 8" DIA. 13,000 Ibs. 144' 150" 208" 8" DIA. 16,000 Ibs. 144" 168" 218' 10" DIA. 16,000 XL Ibs. 168' 168" 238" 10" DIA. 20,000 Ibs. 168' 192" 255" 10" DIA. 27,000 Ibs. 192" 192" 272" 10" DIA. �f A STANDARD PILING SPACING MI5 CONSTRUCTION HAS BEEN DESIGNED AS A MAIN WIND FORCE RE515TING SYSTEM, MTN CALCULATED GRAVITY AND WIND LOADS IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, 7Fh EDITION, 2020, CHAPTERS 16 # 20. ADM 2015, AND A5CFJ5EI 7.16 'MINIMUM DE51GN LOADS FOR BUILDINGS AND OTHER 5TRUCf ORES' TO WITHSTAND THE WIND LOADS A550CIATED WITH AN ULTIMATE WIND SPEED OF 160 MPH, EXPOSURE'D', R15K CATEGORY I. J. L. SANDERS, P.E. HAS NO CONTROL OF THE MANUFACTURING. PERFORMANCE, OR INSTALLATION OF THIS PRODUCT. THESE GENERIC 5PECIFICATION5 WERE ENGINEERED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICES BASED ON DATA PROVIDED BY THE MANUFACTURER. TH15 STRUCTURAL REVIEW 15 LIMITED TO THE PRIMARY FRAMING AND CONNECTIONS AND 15 NOT INTENDED TO COVER MECHANICAL AND ELECTRICAL COMPONENTS. THESE SPECIFICATIONS ARE BASED ON STRUCTURAL CALCULATIONS TITLED'4 P05T BOAT LIPP. WHICH CONTAIN ADDRIONAL DESIGN REQUIREMENTS AND CRITERIA AND AM AVAILABLE UPON REQUEST. THE BOAT LIFTS DEPICTED IN THESE SPECIFICATIONS AND RELATED CALCULATIONS WERE ENGINEERED AS MANUFACTURED PRODUCT FOR NON -SITE SPECIFIC USE AND NOT INTENDED TO COVERSITF. SPECIFIC CONDITIONS, REOUIREMENT5 AND UMITATION5 L15TED IN THE STRUCTURAL CALCULATIONS. J.L: 5aM-, P.E. 2515 Gnt. Read NW Monroe, GA 30656 1L. SANDERS, P.E. Date: Pb- 239-671-1578 Reg. Fln,da No. 66361 SIGNATURE NOT VALID WITHOUT RAISED SEAL NOTE: BOATS SHALL NOT BE STORED ON LIFTS DURING HIGH WIND EVENTS. LIFT CAPACITY CABLE BEAM SIZE CRADLE SIZE GROOVED CABLE DRIVE SHAfT GEAR NO. Of MOTORS CABLES CABLE LIFT SPEED GUIDE BOAT BUNKS BOAT BUNKS CUSTOM CHANNEL 1-5EAM WINDER 51ZE 51ZE RATIO € H P 5Pw P05T Ibs. 6061-T6,6005A-T5 6061-T6,6005A-T5 inches Inches INCHES "�A1° HEIGHT WOODOPTIONALUM.OPTION 4,500 5 x .230 H 6 x .190 H 4 x W 2.375 DIA. 17' Length 1.9 0 TUBE 375:1 (2)3/a 5V/22A 5/30 SSAC 101 36 7 2 x 8 x 144 144 2 X .160 W .290 120 L LIFTS 14 FT. 9 9a 3OV11 23Dv/t to 2U 304, 1 P 20' 7,000 6 x .230 H 6x .190 H 4 x .290 W 2.375 DIA. ' 17' Length 1.9 0 TUBE 375:1 (2)3/4H.P-115V/22A 5/16 SSAC 7x19 113 36 7 2 x 8 x 144 144 2 X .160 W 144 L LIFTS 14 FT. 9 9a - 23Dv/11A 304, 1 P 2U 10,000 7 x .230 H 8 x .230 H 5 x W 2.375 DIA. 20' Length _ 1 9 0 TUBE 375:1 (2)3/4H.P-115v/22A 5/16 SSAC 7xl9 110 18 7 2 x 8 x 144 144 2 X .160 W .350 150 L LIFTS'12 FT. 9 ga 23Dv/t to 304. 2P 38' 13,000 8 x .230 H 8 x .230 H 5 x'350 W 2.375 DIA. 20' Len th375:1 1.9 0 TUBE 5/30 SSAC 110 18 7 2 x 8 x 144 144 2 X .160 W 150 L LIFTS 12 FT. 9' ga 23Dv/13A 30 I'3 304, 2P 38' 38' 16,000 11 x .230 H 10 x .250 H 6 x W 2.375 DIA. 20' Length ' 1 9 0 TUBE - 375:1 (2)1H.P 5/16 SSAC 7x19 110 18 10 3 x 10 x 168 192 2 x .160 W .410 168 L LIFTS 12 FT. . 8 ga 23OV/13A 304, 2P 38' 16,000 XL 11 X .230 H 10 x .250 H 6 x W 2.375 DIA. 20' Length 1.9 0 TUBE 375:1 5/16 9 2P 134 18 10 3 x 10 x 192 192 2 x .160 W .410 168 L LIFTS 12 FT. 8 9a z32)1H.P 304, 36' 20,000 12 x .266 H 12 x .290 H 7 x W 2.375 DIA. 1.9 0 TUBE 375:1 (2)1 H.P 5/16 SSAC 7x19 123 12 10 3 x 1 x 2 2 x 172 W .470 192 L 25' Length LIFTS 12 FT. - 8 9a 23ov/13A 304, 3P 60' . 27;000 14 x .313 H 2 W 12 x .290 H 7 x .470 W 3.5 DIA. 21' Length 2.875 0 TUBE 8 ga 450:1 (2)1-t/2 H.P 23Dv/teA 5/16 SSAC 7x19 304, 4P 74' 147 11 1 �: x � � I X .313 192 L LIFTS FT. IMM BOAT LIFTS, INC. IS NOT RESPONSIBLE FOR THE DOCK STRUCTURE OR ITS ABILITY RESIST THE APPLIED LOADS OF THE BOAT LIFT. THE SITE SHOULD BE VERIFIED BY A LICENSED MARINE CONTRACTOR. APPLIED LOADS WILL BE PROVIDED UPON REQUEST. PLIANCE 1§* COUNTY ��g yp i���pp - BOAT LIFTS---- �'+�+ DWG: 6CBO UM PUB June 19, 2021 17030 Ahco Center Rd. Ft. Myers, M. 339G7 Phone: (800) 669-3515 Fax: (239) 454-864 I PLATINUM WIRING SCHEMATIC MINIMUM RECOMMENDED WIRE SIZE TABLE (AWG) COPPER WIRE ONLY MAXIMUM DISTANCE .FROM SERVICE TO CONTROLLER LIFT CAPACffY 75 FEET 150"FEET 300 FEET 400 FEET 00# #10 #8 #6 #6 AT 120 20TVOLTS TO 00# # 12 # 10 #8 #6 AT 240 VOLTS 16000# TO 27000# # 10 #8 #6 #4 AT 240 VOLTS 000# AT 240 TO #6 #4 #2 #0 120 / 240 V MOTOR 1 O 14/5 SJTW CORD 3/4 hp 12/5 SJTW CORD 1 hp U O 14/5 SJTW CORD 3/4 hp 12/5 SJTW CORD 1 hp 120 / 240 V MOTOR 2 MAIN PANEL (BY OTHERS) 120 / 240 GFCI BREAKER a REVERSING REVIEWED FOR CONTACIGODE COMPLIANCE ST. LUCIE COUNTY BOCC TO MAIN PANEL WITH GFCI BREAKER I-- REFER TO "STANDARD PILING SPACING CHART' -1 MOTOR ELECTRIC MOTOR CONTROL " GUIDEPOST .. (NOT SHOWN) SWITCH W/GFCI I I CARPETED WOOD DOCK 1 CCA TREATED j WOOD BUNKS 1 STAINLESS j OR ALUMINUM STEEL CABLES 1/2" PVC I I P.T. WOOD PILE CONDUIT ELECTRICAL L (3' MIN. INTO ROCK) (8' MIN. INTO SAND) DWG: GOO 100 - PLATINUM PUB June 15, 2021 17030 Ahco Center Rd. Ft. Myers, FI. 339G7 Phone: (800) GG9-3515 Fax: (239) 454-8G41 I