Loading...
HomeMy WebLinkAboutAPPROVED CWS-FL16177.1 8100 SH8100 PVCSINGLE HUNGIMPACTCWS-812DBAT06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:15SHEET1 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.XO30 3/16"MAX.SASHHEIGHT63"MAX.OVERALLFLANGEHEIGHT53 1/8" MAX. OVERALL FLANGE WIDTH51 7/8" MAX. UNIT WIDTH61 3/4"MAX.UNITHEIGHT26 7/8"GLASSDLO45 1/16"GLASS DLO26 13/16"GLASSDLO47 11/16" GLASS DLO48 3/8"MAX. SASH WIDTHA6B6GENERAL NOTES ANDELEVATIONSGENERAL NOTES:1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC.2. GLAZING OPTIONS: (SEE SHEET 2)3. CONFIGURATIONS: "O/X".4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09.5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED.7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT USED AT FIXED MEETING RAIL AND JAMB.8. SERIES / MODEL DESIGNATION SH-8100.9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERABLE SASH, O = FIXED SASH10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION.11. EXTERNAL WEEP SLOT = 1/4" x 1-1/4" LOCATED 4" FROM BOTH ENDS. TABLE OF CONTENTSGENERAL NOTES & ELEVATIONS.....1GLAZING DETAIL.................................2SECTION VIEWS.................................3 EXTRUSIONS & B.O.M........................4ANCHOR SCHEDULE & NOTES.........5INSTALLATION DETAILS....................6SINGLE HUNG - LARGE MISSILE IMPACTMAX. UNIT SIZEDESIGN PRESSURE RATINGIMPACT RATING51-7/8" x 61-3/4" +/- 70 PSF LARGE MISSILE IMPACTC6AABB8/05/2020 8100 PVCSINGLE HUNGIMPACTCWS-812DBAT06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:1SHEET2 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.7/8" OVERALL INSULATED GLASS1/8" ANNEALED OR TEMPERED7/16" AIRSPACE1/8" ANNEALED.090" PVB INTERLAYER1/8" ANNEALED5/16" LAMINATED GLASSFIXED LITE47 PURFECT GLAZE "H" OR SIKAFLEX 552711448*SASH LITE7/8" OVERALL INSULATED GLASS1/8" ANNEALED OR TEMPERED7/16" AIRSPACE5/16" LAMINATED GLASS1/8" ANNEALED.090" PVB INTERLAYER1/8" ANNEALED47 PURFECT GLAZE "H" OR SIKAFLEX 5521448*1223GLAZING DETAILS* SETTING BLOCKS PER FBC 2411.3.3.1QUANEX DURASEAL or,CARDINAL XL EDGE or,KODISPACE 4SG TPSI.G. SPACERQUANEX DURASEAL or,CARDINAL XL EDGE or,KODISPACE 4SG TPSI.G. SPACER1/2" GLASS BITE1/2" GLASS BITE8/05/2020 8100 PVCSINGLE HUNGIMPACTCWS-812DBAT06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET3 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.67374SECTION A-ASECTION B-BNOTE: LEFT SIDE SHOWS FIXED SECTION VIEW,RIGHT SIDE SHOWS SASH SECTION VIEW.1145498105330345324124513321414141432323232244862656619INTERIOR21854392827NOTE: ITEMS NOT SHOWN FOR CLARITY:20, 25-26, 36-37, 44, 51-52, 55-56, 64, 67-68636665627172SECTION VIEWSINTERIOR455338272332708/05/2020 8100 PVCSINGLE HUNGIMPACTCWS-812DBAT06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET4 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.LINE ITEMS NOT USED:5, 7, 11, 15-17, 21-22, 29, 31, 33-36, 41-43, 46, 49-50, 55, 57-61, 69REINF., IMPACT HOOK - 11127/8"9/16"731237181020913191272PVC SASH STOP - 60257/8"1 5/16"1/16"14CORNER WELD(ALL SIDES)1:8FRAME CORNERCONSTRUCTIONFIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME1:837BOM AND EXTRUSIONSNOTE: ALL ALUMINUM EXTRUSIONS ARE 6063-T6 UNLESS OTHERWISE NOTED.18231/16"IMPACT HOOKS-15775"7/8"1 5/16"1/16"64REINF.H-21231 3/16"1 5/8"1/16"3/4"15/16"1/16"PVC SASH PULLRAIL/STILE H-6223PVC SASH MTGRAILH-6224PVC FRAMEFLANGEH-6222PVC SASHRAIL/STILEH-62251 15/16"1 5/8"1/16"2 3/16"1 5/8"1/16"3 1/8"2 3/4"1/16"PVC SCREENSUPPORTS-6227PVC SCREENCATCHS-6226PVC GLAZINGBEADS-6237REINF.S-2129REINF. SASH MTGRAILH-21241 1/16"1/4"1/16"1 1/16"7/16"1/16"1"5/8"1/16"5/8"5/16"7/8"MTG RAILH-21211 9/16"2 1/8"13/16"1 1/8"PVC MTG RAILCOVERS-6228ITEM PART # DESCRIPTIONMATERIAL1 H-6222 Main Fr., SH, w/Flg., PVC, HeadVinyl2 H-6222 Main Fr., SH, w/Flg., PVC, SillVinyl3 H-6222 Main Fr., SH, w/Flg., PVC, L. Jb.Vinyl4 H-6222 Main Fr., SH, w/Flg., PVC, R. Jb.Vinyl6 S-1577 Impact HookAlum8 H-6224 Sash Meet. Rail, PVCVinyl9 H-2124 Reinf. Sash Meet. RailAlum10 H-6223 Sash Bottom Rail, PVCVinyl12 H-6225 Sash Side/Top/Bot. RailVinyl13 S-2129 Reinf. S.B.R./S.S.R14 S-6237 Glz. Bd., 7/8"Vinyl18 S-6226 Scrn. Adapt., w/Nib, PVC, Horiz.Vinyl19 S-6227 Scrn. Adapt., PVC, Vert.Vinyl20 S-6025 Sash Stop / Filler, PVC, Vert.Vinyl23 H-2123 Reinforcement, SBRAlum24Balance25 P-3059 Sash Cam, PVCPlastic26 P-3046 Take Out ClipSS27 P-3783 Lock, Impact, PVC28 P-4069 Keeper, Impact, PVCZamac30 P-3215 Weep Cover w/ FlapPlastic32 P-3429 Wstp., 0.270 x .187 back FinSeal, Gray37 P-4638 #8 x 2-1/2 PH Mod. Truss, Type A, TEK 2 Steel38 P-3768 #8 x 0.625 Ph PH SMSSteel39 P-4051W #8 x 1.250 Ph FH TEK, Wht.Steel40 P-4264W #8 x 3/4 FH PH w/#6 Head, TEK, Wht. Steel44 P-3342 Seam Sealer, SM-550445 P-5588 Cap Plug, 1/2" HoleNylon47 P-3438 Sikaflex 552 or Purfect Glaze "H"48 P-5615 Set. Blk., 85 Dur., 1/8" x 1" x 2" Lg. Rubber51 P-3881 Temporary Lbl. (NFRC/DP)52 P-3613 CWS Lbl. (logo)53 Sash SEE SHEET 254 Fixed SEE SHEET 256 P-3281 Spacer62 P-3218 Screen Frame, Horiz.Alum63 P-3218 Screen Frame, Vert.Alum64 P-3321 Screen Frame Corner KeyPlastic65 P-3581 Screen Cloth, 18 x 16 FiberglassFiberglass66 P-3228 Screen Spline, .155 Dia., Blk.Vinyl67 P-3029 Screen Pull TabAlum68 P-3033 Screen Spring, SSSS70 P-4959 Wstp., 0.270 x .187 back FinSeal, Gray71 H-2121 Alum. Fixed RailAlum72 S-6228 Cover, Fixed RailVinyl73 S-1112 Reinforcement, Impact HookAlum74 P-3541 #8 x 1/2", Pan Head, TEKSteelPARTS LIST8/05/2020 8100 PVCSINGLE HUNGIMPACTCWS-812DBAT06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:15SHEET5 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.XOSEE NOTE 2INSTALLATIONANCHOR (TYP.)6" MAX. (TYP.)6" MAX. (TYP.)ANCHOR LAYOUT - (FLANGE)NO ANCHORS REQUIRED IN SILL17" MAX. O.C. (TYP.)4" (TYP.)4" (TYP.)10 1/2"MAX. O.C.(TYP.)ANCHOR SCHEDULE ANDNOTESNOTES:1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. NO ANCHORS REQUIRED IN SILL.2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6.4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION.5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6.6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.7. A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL.8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS)10 1/2"MAX. O.C.(TYP.)4" (TYP.)MTG RAILLC8/05/2020 8100 PVCSINGLE HUNGIMPACTCWS-812DBAT06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET6 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.VERTICAL SECTIONTYPICAL SILL ANCHORAGEA6B6HORIZONTAL SECTIONTYPICAL JAMB ANCHORAGEINSTALLATION DETAILSTYPICAL HEAD ANCHORAGESUBSTRATE TYPEANCHOR TYPEMIN. EMBEDMENT MIN. EDGE DIST.CONCRETE (2.0 KSI MIN.)3/16" ITW TAPCON1-1/2"1-1/8"HOLLOW OR GROUT-FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON1"2"CONCRETE (2.85 KSI MIN.)3/16" ELCO ULTRACON1"1"GROUT-FILLED CMU (ASTM C-90)3/16" ELCO ULTRACON1-1/4"2-1/2"2X MIN. SOUTHERN PINE (G=0.55)3/16" ITW TAPCONOR ELCO ULTRACON1-3/8"7/8"2X MIN. SOUTHERN PINE (G=0.55)#10 WOOD SCREW1-3/8"7/8"16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN)#10-16 HILTI KWIK-FLEX OR ITW TEKS SELF-DRILLING SCREWFULL THREAD THRU 0.060"7/16"1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.)#10 GRADE 5 SELF-TAPPING / DRILLING SCREWFULL THREAD THRU 0.125"7/16"TABLE 1: APPROVED INSTALLATION FASTENERSMIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1MIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1PERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTSEALANT BEHINDFLANGE BY INSTALLERSEALANT BEHINDFLANGE BY INSTALLERSEALANT BEHINDFLANGE BY INSTALLERINSTALLATION ANCHORSEE TABLE 1INSTALLATION ANCHORSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: - MIN. 1/4" FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. - PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS.C6HORIZONTAL SECTIONBOX FRAME INSTALLATIONHEAD AND SILL SIMILAR FOR BOX INSTALLATIONMIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1CONTINUOUS DOUBLE 3/16" BEADS OF TREMGLAZE U1600 SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND BUCK BY INSTALLER.1/4" MAX SHIM1/4" MAX SHIM1/4" MAX SHIM8/05/2020