HomeMy WebLinkAboutAPPROVED CWS-FL5823.1 8100 SH8100 PVCSINGLE HUNGIMPACTCWS-155EADE06/10/08 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:1SHEET1 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.49 11/16"MAX. SASH WIDTH48 15/16"GLASS DLO33 15/16"GLASSDLO46 3/8"GLASS DLO34"GLASSDLO76"MAX.UNITHEIGHT53 1/8" MAX. UNIT WIDTH54 3/8"OVERALL FLANGE WIDTH77 1/4"MAX.OVERALLFLANGEHEIGHT37 5/16"MAX.SASHHEIGHTXO28"GLASS DLO27"GLASSDLO30 5/16"MAXSASHHEIGHT62"MAXUNITHEIGHT31 13/16"GLASS DLO36"MAX UNIT WIDTH37 1/4"OVERALL FLANGE WIDTH63 1/4"OVERALLFLANGEHEIGHT31 5/16"MAX SASH WIDTHXO27"GLASSDLOA6B6 GENERAL NOTES ANDELEVATIONSGENERAL NOTES:1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC.2. GLAZING OPTIONS: (SEE SHEET 2)3. CONFIGURATIONS: "O/X".4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09.5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.6. PRODUCT APPROVED FOR IMPACT RESISTANCE. THE IMPACT SWEEP LOCKS ARE INTENDED TO BE LEFT UNLATCHED DURING NORMAL OPERATION BUT MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND FLYING DEBRIS.7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT USED AT FIXED MEETING RAIL AND JAMB.8. SERIES / MODEL DESIGNATION SH-8100.9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERABLE SASH, O = FIXED SASH10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION.11. EXTERNAL WEEP SLOT = 1/4" x 1-1/4" LOCATED 4" FROM BOTH ENDS.12. SWEEP LOCKS INSTALLED ON WINDOWS OVER 36" x 62". TABLE OF CONTENTSGENERAL NOTES & ELEVATIONS.....1GLAZING DETAILS...............................2SECTION VIEWS & ALT. FRAME........3 EXTRUSIONS & B.O.M.........................4ANCHOR SCHEDULE & NOTES..........5INSTALLATION DETAILS.....................6SINGLE HUNG - LARGE MISSILE IMPACT(SHOWN w/DIFFERENT OPTIONS)LOCATION MAX. UNIT SIZEDESIGN PRESSURE RATINGIMPACT RATINGNON-HVHZ+/- 65 PSFHVHZ+/- 67.5 PSFNON-HVHZ+65 / -75 PSFHVHZ+67.5 / -75 PSFLARGE MISSILE IMPACT53-1/8" x 76"36" x 62"C6D6AABBCC8/05/2020
8100 PVCSINGLE HUNGIMPACTCWS-155EADE06/10/08 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:1SHEET2 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.7/8" OVERALL INSULATED GLASS1/8" ANNEALED7/16" AIRSPACE1/8" ANNEALED.090" PVB INTERLAYER BY DUPONT1/8" ANNEALED5/16" LAMINATED GLASSGLASS TYPE AFIXED LITE18 PURFECT GLAZE "H" OR SIKAFLEX 55241238*GLAZING DETAILS7/8" OVERALL INSULATED GLASS1/8" TEMPERED7/16" AIRSPACE1/8" ANNEALED.090" PVB INTERLAYER BY DUPONT1/8" ANNEALED5/16" LAMINATED GLASSGLASS TYPE BFIXED LITE18 PURFECT GLAZE "H" OR SIKAFLEX 55241238*GLASS TYPE ASASH LITE7/8" OVERALL INSULATED GLASS1/8" ANNEALED7/16" AIRSPACE5/16" LAMINATED GLASS1/8" ANNEALED.090" PVB INTERLAYER BY DUPONT1/8" ANNEALED18 PURFECT GLAZE "H" OR SIKAFLEX 552GLASS TYPE BSASH LITE7/8" OVERALL INSULATED GLASS1/8" TEMPERED7/16" AIRSPACE5/16" LAMINATED GLASS1/8" ANNEALED.090" PVB INTERLAYER BY DUPONT1/8" ANNEALED18 PURFECT GLAZE "H" OR SIKAFLEX 55238*38** SETTING BLOCKS PER FBC 2411.3.3.1QUANEX DURASEAL or,CARDINAL XL EDGE or,KODISPACE 4SG TPSI.G. SPACERQUANEX DURASEAL or,CARDINAL XL EDGE or,KODISPACE 4SG TPSI.G. SPACERQUANEX DURASEAL or,CARDINAL XL EDGE or,KODISPACE 4SG TPSI.G. SPACERQUANEX DURASEAL or,CARDINAL XL EDGE or,KODISPACE 4SG TPSI.G. SPACER1/2" GLASS BITE1/2" GLASS BITE1/2" GLASS BITE1/2" GLASS BITE8/05/2020
8100 PVCSINGLE HUNGIMPACTCWS-155EADE06/10/08 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET3 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.ITEMS NOT SHOWN FOR CLARITY:22, 27-28, 33-37, 43-45SECTION VIEW B-BNOTE: LEFT SIDE SHOWS FIXED SECTION VIEW,RIGHT SIDE SHOWS SASH SECTION VIEW.SECTION VIEW A-ANO SWEEP LOCKS ALLOWEDFOR UNITS 36" x 62" AND UNDER.SECTION VIEW C-CSWEEP LOCK REQUIREDFOR SIZES OVER 36" x 62".232019781225201221124012141384532293261011153921463013141516314812ALTERNATE FIN FRAME19INTERIORINTERIOR96SECTION VIEWS478/05/2020
8100 PVCSINGLE HUNGIMPACTCWS-155EADE06/10/08 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET4 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.1234684271125105PVC SASH STOP - 60257/8"1 5/16"1/16"12CORNER WELD(ALL SIDES)1:8FRAME CORNERCONSTRUCTIONFIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME1:822BOM AND EXTRUSIONSNOTE: ALL ALUMINUM EXTRUSIONS ARE 6063-T6 UNLESS OTHERWISE NOTED.47269REINF.H-21231 3/16"1 5/8"1/16"3/4"15/16"1/16"PVC FRAMEFIN/FLANGEH-6231PVC SASH PULLRAIL/STILE H-6223PVC SASH MTGRAILH-6224PVC FRAMEFLANGEH-6222PVC SASHRAIL/STILEH-62253 1/8"3 9/16"1/16"1 15/16"1 5/8"1/16"2 3/16"1 5/8"1/16"3 1/8"2 3/4"1/16"PVC SCREENSUPPORTS-6227PVC SCREENCATCHS-6226PVC GLAZINGBEADS-6237REINF.S-2129REINF. SASH MTGRAILH-21241 1/16"1/4"1/16"1 1/16"7/16"1/16"1"5/8"1/16"5/8"5/16"7/8"MTG RAILH-2121PVC MTG RAILCOVERS-62281 9/16"2 1/8"13/16"1 1/8"ITEM PART # DESCRIPTIONMATERIAL1 H-6222 Frame Head, Flg, Single HungPVC2 H-6222 Frame Sill, Flg, Single HungPVC3 H-6222 Frame Jamb, Flg, Single HungPVC4 H-2121 Alum. Fixed Meet. RailALUMINUM5 S-6228 Fixed Rail CoverPVC6 H-6224 Sash Top RailPVC7 H-2124 Reinforcement for STRALUMINUM8 H-6223 Sash Bottom RailPVC9 H-2123 Reinforcement for SBRALUMINUM10 H-6225 Sash Side RailPVC11 S-2129 Reinforcement for SSRALUMINUM12 S-6237 Glazing BeadPVC13 P-3118 Keeper, Sweep LockZINC14 P-3541 #8 x 1/2", Pan Head, TekSTEEL15 P-4632 Sweep LockZINC16 P-4633 Barrel FastenerSTEEL17Block & Tackle BalanceSTEEL18Purfect Glaze "H" or Sikaflex 552 SILICONE19 Sash SEE SHEET 2GLASS20 Fixed SEE SHEET 2GLASS21 P-3429 Wstp., 0.270 x 0.187 back FinSeal NYLON22 P-4638#8 x 2-1/2 PH Mod. Truss, Type A, TEK 2STEEL25 S-6227 Screen Catch PVC26 S-6226 Screen Support PVC27 P-4051 #8 x 1 1/4" Ph Fh TEK, Wht. ZINC28 P-3748 #6 x 0.625" Quad Fh TEK, Wht. ZINC29 P-3783 Impact, Lock STEEL30 P-4069 Impact, Keeper STEEL31 P-4264 #8 x 3/4 FH PH w/#6 Head, TEK, Wht STEEL32 P-3218 Screen Frame ALUMINUM33 P-3321 Screen Corner Key PLASTIC34 P-3228 Screen Spline RUBBER35 P-3581 Screen Cloth VINYL36 P-3033 Screen Spring STEEL37 P-3029 Screen Pull Tab STEEL38 P-5615 Set. Blk. 85 Dur. 1/8" x 1" x 2" RUBBER39 P-3768 #8 x 5/8 Phil Pan Zinc ZINC40 P-4479 Weepcover PLASTIC42 P-6025 Sash Stop PVC43 P-3059 Sash Cam PLASTIC44 P-3295 Take Out Clip STEEL45 P-3342 Seam Sealer SILICONE46 P-5588 Hole Plug PLASTIC47 H-6231 Frame Head, FIN, Single Hung PVC48 P-4959 Wstp., 0.420 x 0.187 back NYLONPARTS LIST8/05/2020
8100 PVCSINGLE HUNGIMPACTCWS-155EADE06/10/08 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:25SHEET5 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.15" MAX. O.C. (TYP.)14"MAX. O.C.(TYP.)6" MAX. (TYP.)6" MAX. (TYP.)XOXO6" MAX. (TYP.)6" MAX. (TYP.)10 13/16"MAX. O.C.(TYP.)XOXO4" MAX. (TYP.)4" MAX. (TYP.)8"MAX. O.C.(TYP.)8" MAX. O.C. (TYP.)ANCHOR LAYOUT - (FLANGE)SIZES OVER 36" x 62"4" MAX. (TYP.)4" MAX. (TYP.)8" MAX. O.C. (TYP.)8"MAX. O.C.(TYP.)ANCHOR AT MIDSPAN (TYP.)4" (TYP.)4" (TYP.)4" (TYP.)LCMTG RAILLCMTG RAILANCHOR LAYOUT - (FIN)SIZES OVER 36" x 62"ANCHOR LAYOUT - (FLANGE)SIZES 36" x 62" AND UNDERANCHOR LAYOUT - (FIN)SIZES 36" x 62" AND UNDER ANCHOR SCHEDULE ANDNOTESNOTES:1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD.2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6.4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION.5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6.6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.7. A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL.8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS)8/05/2020
8100 PVCSINGLE HUNGIMPACTCWS-155EADE06/10/08 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET6 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.VERTICAL SECTIONTYPICAL SILL ANCHORAGEA6B6HORIZONTAL SECTIONTYPICAL JAMB ANCHORAGEINSTALLATION DETAILSTYPICAL HEAD ANCHORAGEC6HORIZONTAL SECTIONTYPICAL FIN ANCHORAGEHEAD AND SILL SIMILAR FOR FIN INSTALLATIONFRAME TYPE SUBSTRATE TYPEANCHOR TYPEMIN. EMBEDMENT MIN. EDGE DIST.FLANGE CONCRETE (2.0 KSI MIN.)3/16" ITW TAPCON1-1/2"1-1/8"FLANGE HOLLOW OR GROUT-FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON1"2"FLANGE CONCRETE (2.85 KSI MIN.)3/16" ELCO ULTRACON1"1"FLANGE GROUT-FILLED CMU (ASTM C-90)3/16" ELCO ULTRACON1-1/4"2-1/2"FLANGE 2X MIN. SOUTHERN PINE (G=0.55)3/16" ITW TAPCONOR ELCO ULTRACON1-3/8"7/8"FLANGE 2X MIN. SOUTHERN PINE (G=0.55)#10 WOOD SCREW1-3/8"7/8"FLANGE16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN)#10-16 HILTI KWIK-FLEX OR ITW TEKS SELF-DRILLING SCREWFULL THREAD THRU 0.060"7/16"FLANGE1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.)#10 GRADE 5 SELF-TAPPING / DRILLING SCREWFULL THREAD THRU 0.125"7/16"FIN2X MIN. SOUTHERN PINE (G=0.55)#8 WOOD SCREW1-1/2"7/16"TABLE 1: APPROVED INSTALLATION FASTENERSMIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1MIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1MIN. EDGE DIST.SEE TABLE 1MIN. EMBEDMENTSEE TABLE 1PERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTSEALANT BEHINDFLANGE BY INSTALLERSEALANT BEHINDFLANGE BY INSTALLERSEALANT BEHINDFLANGE BY INSTALLERSEALANT BEHINDFIN BY INSTALLERINSTALLATION ANCHORSEE TABLE 1INSTALLATION ANCHORSEE TABLE 1INSTALLATION ANCHORSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: - MIN. 1/4" FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. - PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS.D6HORIZONTAL SECTIONBOX FRAME INSTALLATIONHEAD AND SILL SIMILAR FOR BOX INSTALLATIONMIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 11/4" MAX SHIM1/4" MAX SHIM1/4" MAX SHIM1/4" MAX SHIM8/05/2020