ARCHITECT CREMATOR CLEARANCES RECOMMENDED MINIMI)11d TOP: GJ 2 FEET 610 mm] 6 INCHES 152 mm] T CABINET SIDE: 4 FEET 1.22 m) 4 FEET 1.22 m] OTHER SIDE: 2 FEET 610 mrn] 6 INCHES 152 mm] FRONT: 9 FEET 2.74 m} 8 FEET 2,44 m] mJ ES 61 REAR: 3 FEET 0.91 32 INCHES mm c a STACK: 6 INCHES 152 mm) 6 INCHES 152 mm] 1, FOR CLEARANCES OTHER THAN THOSE SHOWN, OR FOR SPECIAL REQUIREMENTS, CONSULT YOUR MCD REP. .`JFROM HIGHEST POINT ON UNIT. 3. CONTROL CABINET MOUNT$ ON UNITS LEFT OR RIGHT SIDES, OR REMOTELY, (SEE PLAN VIEW, SHEET 1). 4. REAR OF UNIT REFERS TO THE "BACK PLATE", RATHER THAN THE BACK OF THE "Ar"SPERSHIELD'•. (SEE PLAN VIEW, SHEET 1), CREMATOR REQUIREMENTS STACK 1 tfk-LATION INSTRUCTIONS FUEL: A PRESSURE REGULATOR ADJUSTABLE TO 7" 1178 mm] W C. FOR PiATURAL GAS, OR 11" (279 mm] W.C. FOR LP GAS, SF.'r 'F CAPACITY, RANGES FROM 2,0 TO 4.0 MILLION BTU/HR (2.1 TO 3.1 MILLION KILOJOULES/HR] DEPENDING UPON AMOUNT OF BURNERS, ELECTRICAL: 230 VOLT, 30, (40A BREAKER) AND 11$Y (IDA BREAKER), QB 230 VOLT, i 0, (70A BREAKER) AND 115Y (1DA BREAKER) 50/60 HERTZ AIR: LOUVER NEAR THE REAR OF THE UNIT CAPABLE OF PASSING 2,500 CU FT MIN 36') (914MmmiNIX 41 mFREEm AIR (36�X 29 1 /4"0 O.D. � •..� STACK (74 m) TEST PORTS 20"0 I,D. TO BE ACCESSIBLE ABOVE ROOF LINE (,51 M) (IF EQUIPPED) 048" (1.22 m j STORM DRAWBAND COLLAR CONNECTION STORM COLLAR 3" (76.2 mm]- ROUND FLASHING (NON-COMBUSTIBLE LINER MUST -BE 45 1/2" (1.16 m DIAMETER FOR PROPER STORM COLLAR OVERLAP (SEE STACK INSTALLATION INSTRUCTIONS /3 & /4) 5" (152.4 mm) MINIMUM FLASHING BELOW ANY COMBUSTOLES, 045 1/2" (1.16 m] REQUIRED FOR PROPER STACK CLEARANCE. I. APPLY A 1/2" THICK MORTAR JOINT TO EXPOSED EFRACTORY SURFACE�N STACK RING, LOWER THE BASE STACK SECTION ONTO STACK RING �.^J AND FASTEN WITH HARDWARE PROVIDED (NO MORE THAN (2) STACK SECTIONS SHALL BE LIFTED TOGETHER). REPEAT PROCESS FOR REMAINING STACK SECTIONS. IF SECTIONS OF VARYING LENGTHS ARE SUPPLIED, ASSEMBLE AS TO AVOID FLANGES & LIFTING YES 1GE E INTERFERING WITH RAIN COLLAR LOCATION. 2, INSTALL STORM COLLAR ON STACK, 3" (72 mm) ABOVE NON-COMBUSTIBLE LINER (FLASHING), ALLOWING FOR PROPER VENTILATION (SEE DETAIL)'. 3. APPLY A 1/4" (6 mm) READ OF HIGH -TEMPERATURE SILICON SEALANT (PROVM BY MCD) TO THE JOINT BETWEEN THE STORM COLLAR C AND THE $$TACK (0. 4. STORM COLLAR IS FURNISHED BY MCD. THE NON-COMBUSTIBLE LINER (FLASHING) TO BE PROVIDED BY THE OTHERS, 5. IF FIFTY PERCENT OF THE STACK LENGTH IS ABOVE THE ROOF, GUY WIRES MAY BE REQUIRED. CONSULT WITH YOUR MCD REP, 6. RAIN CAP NOT REQUIRED, 20" 0 I.D. (2) LIFTING EYES PER STACK SECTION 29 1 /4"0 0. D. -, 36" [.91 m] MINIMUM STACK ABOVE ROOF PEAK (B (MAY VARY BY LOCATION), FASTEN FLANGES TOGETHER r I WITH HARDWARE PROVIDED. ''� STACK INSTALLATION $ C DETAIL "Cfbz f $ [152.4 mrn) MINIMUM 3 FLASHING ABOVE HIGHEST ROOF OPENING POINT. STACK BASE SECTION HAS POLLUTION CONTROL PORTS WHICH SHALL - AIR FLOW AROUND FACE FRONT AND REAR RELATIVE TO UNIT STACK MUST NOT BE OBSTRUCTED FASTEN FLANGES TOGETHER WITH HARDWARE PROVIDED, 1` SECTION JOINING FLANGE r"'/ ROOF PENETRATION STACK RING DETAI ATTACHED TO UNIT PRODUCT REVIEW PRODUCT OPENING DESIGN PRODUCT MANUFACTURER MODEL# APPROVAL# GLASS ATTACHMENT METHOD PRESSURES (WORST DESIGN TYPE CASE) PRESSURES LOUVER +/-35.4 +/- 200 GREENHECK ESD-435X FL # N/A %" SMS SCREWS AT 6.5" O.C. 6876.3 i C xJML FILRCUIV is rRUV,UCU U,v,.r IU mUR-A i t UUK ntV IrVV ANU AVrKUVAL rUK U�,t Ur VRUUUC IS LIS I LD FUR THIS STRUCTURE. THE ACCEPTANCE OF THESE PRODUCTS AND METHODS OF ATTACHMENT ARE BASED ENTIRELY I.IPON TEST DATA PROVIDED BY THE MANUFACTURER, WHICH CARRIES ITS OWN ENGINEER'S CERTIFICATION AND IMPLIES NO WARRANTY OR GUARANTEE BY THIS OFFICE FOR THESE PRODUCTS. P,, �;. s ��. T^'r �` i..�. � a.i. �.4� P.m� • tda � '�""� j�'.. r� S Ce �t� �i •;?r-,. �aW ��A ��t,s{ v �1.� a,r,�`" �E?'.tu. M-`rI�- T e� � SEE P. ABOVE,i2 �d��QlfiaEaT ice. h W/'JkPJ Ct (2 S 7.11, '�; 'C.- c 0/ Z. `Pc Z-r. a Y41 iQ l C P_E-r" 1 A. TO Z,. t-,1 o r:"_e:, r IFS 0. L1 SEE 1. ABOVE. 5-f, ? a, � f�^ 1 + m T. � i T .1=^ BUILDING INFORMATION: 2020 FLORIDA BUILDING CODE LEVEL 11 ALTERATIONS BUILDING AREA: EXISTING BUSINESS 264 S.F. EXISTING FACTORY 1836 S.F. PROPOSED FACTORY 2982 S.F. TOTAL 5082 S.F. GROUP: B BUSINESS F-1 MODERATE HAZRD FACTORY 1 OCCUPANT LOAD PER TABLE 1004.1.2 BUSINESS 264 / 100 = 2.64 FACTORY 4818 / 500 = 9.63 TOTAL 13 CONSTRUCTION TYPE: TYPE VB ALLOWABLE AREA PER TABLE 503: GROUP B 9,000 S.F. GROUP F-1 8,500 S.F. BUILDING IS NON-SPRINKLERED OVEN CLASSIFICATION PER NFPA 86 CLASS A OVENS REQUIREMENTS FOR AREA OF IMPROVEMENTS REQUIRED NUMBER OF FIXTURES PROVIDED NUMBER OF FIXTURES 1 WATER CLOSETS 2 WATER CLOSETS 1 LAVATORIES 2 LAVATORIES 0 SERVICE SINK 2 SERVICE SINK 0 DRINKING FOUNTAIN 0 DRINKING FOUNTAIN REQUIRED EXIT WIDTH 36" PROVIDED EXIT WIDTH PROVIDED 288" REQUIRED NUMBER OF EXITS 2 PROVIDED NUMBER OF EXITS 8 REQUIRED ADA CORRIDOR WIDTH 42" PROVIDED ADA CORRIDOR WIDTH 42" TRAVEL DISTANCE ALLOWED 200' TRAVEL DISTANCE PROVIDED 57.5' Certifi ation for Design Load Co Hance 1. DESIGN CODE; Florida Su i S 1 ry . code 2020 Edition w/20_,_•_ supplements using ASCE 7.16 2, Structure Design is: Enclosed _ Partially Enclosed Open Building 3, Risk Category: __,__I II ____ III ,.,,,,,,_IV Exposure Category: 9 ry: ?� B _„-C -_•-D Adjustment coefficient 4. Design Wind Velocity 140 mph _Aso, ..LRFD End Zone Width A ft. 5. Mean Roof Height: �O ft. Roof Pitch: tLJ12 Parapet _ft. 6. Components & Cladding Design Pressure used: (PSF, based on Actual sq. ft. @ d 'MRH (worst case) Zone 1:- '-�T I Zone 2: -b Zone 3:-�44'Zone 4:- 29,2 Zone 5:-3_ __' Garage: rig`^ 7. Design Loads: Floor: e,, rPSF Roof/4ead:�X fPSF Roof/Live LY.fFPSF Balcony: • PSF Dock: „-PSF Deck: PSF Stairs: _ PSF Fence: PSF Railing: PSF 8. Were Shear Walls Considered for Structure? zYes _Not Applicable Explain Why Not: 9. Is a Continuous Load Path provided? Yes _W_._Not applicable Explain Why Not: 0. Minimum,soil bearing pressure 2000 P.S,F. RECEIVED MAR 3 1 2071 Permitting Department St. Lucie County EQUIPMENT SCHEDULE NUMBER EQUIPMENT DESCRIPTION 1 PP II CREMATORY 2 BLIP 500 CREMATORY 3 SHELVING UNIT 4 MEDICAL WASTE 5 PROCESSOR 6 CHEST FREEZER 30" D X 55" W 7 SPECIALIZATION PAW PRINTS 8 SCALE 9 IN COOLER C 6'It c>T k1 OE �WALIK 18-1'6-1-G CREMATORY WALL LEGEND. EXISTING WALLS TO REMAIN EXISTING WALLS TO BE REMOVED Architectonic Inc 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 WWW.ARCHITECTONICINC.COM STATE REG # AA26003348 COPYRIGHT 2020 PROJECT PET ANGEL EXPANSION ST. LUCIE COUNTY, FLORIDA CLIENT CONSULTANTS REGISTRATION MICHAEL J. SEAL, AIA AR96898 ZEVISIONS NO, DATE REVISION KEY PLAN t SHEET TITLE / SHEET NUMBER 0 PROJECT NUMBER z I! 0o7 DATE DUCTWORK SYSTEM SYMBOLS SYMBOL DESCRIPTION ® SUPPLY AIR DUCT SECTION (UP/DOWN) zRETURN, OUTDOOR OR EXHAUST AIR DUCT SECTION (UP/DOWN) z ©j OUTDOOR AIR DUCT SEC11ON (UP/DOWN) z ©j EXHAUST AIR DUCT SECTION (UP/DOWN) RETURN, EXHAUST OR TRANSFER AIR FLOW SUPPLY AIR FLOW M D ❑-AvY- MOTORIZED DAMPER VD MANUAL VOLUME DAMPER FD >- FIRE DAMPER SD >- SMOKE DAMPER AD 0 ACCESS DOOR FLEXIBLE DUCT CONNECTION ELBOW WITH TURNING VANES SUPPLY DIFFUSER WITH 4-WAY BLOW SUPPLY DIFFUSER WITH 2-WAY BLOW SUPPLY DIFFUSER WITH QUADRANT BLOCK OSD - SIDEWALL DIFFUSER aRETURN, TRANSFER OR EXHAUST GRILLE OR REGISTER ® EXHAUST FAN ROUND CEILING DIFFUSER LINEAR DIFFUSER CDP-I AIR DEVICE, TYPE AND CAPACITY 100 SQUARE TO ROUND TRANSITION ..-- EXISTING DUCTWORK OR EQUIPMENT TO REMAIN - - - EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED NEW DUCTWORK OR EQUIPMENT OROOF CENTRIFUGAL FAN, EXHAUST OROOF CENTRIFUGAL FAN, SUPPLY ELECTRIC DUCT HEATER 2" UNDERCUT CONTROL SYMBOLS THERMOSTAT - 4'-0" A.F.F. MOUNTING HEIGHT HUMIDISTAT - 4'-0" A.F.F. MOUNTING HEIGHT �- TEMPERATURE SENSOR ©- STATIC PRESSURE SENSOR ® DUCT SMOKE DETECTOR /VD VOLUME DAMPER /AD AUTO DAMPER HVAC PIPING LEGEND CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN HWS HOT WATER SUPPLY HWR HOT WATER RETURN - - - - - REFRIGERANT PIPING CD CONDENSATE DRAIN FROM COOLING COIL - DOMESTIC COLD WATER G GAS PIPING L � � � � � � � � � � �0,00AH �f � No NO,, � 2"x2"x1/4" ANGLE FASTEN BOLTS TO WALL ABOVE AND BE WALL MOUNTED EXHAUST FAN WIT WIRE GUARD & MC MOUNT: SEE PLAN & SCHEDULE FOR LOCATIONS 8 CAPACITIES MOTOR GUARD DAMPER BIRDSCREEN LOUVER: WITH RAINSTOPS & GUTTERS SEE ARCH. PLANS & SPECIFICATIONS (IMPACT RATED) NOTE: EXHAUST FAN SHOWN - SUPPLY FAN SIMILAR EXCEPT AIRFLOW AND DAMPER DIRECTION. SIDEWALL EXHAUST / SUPPLY FAN DETAIL SCALE _ (N.T.S.) NO rE: SOME NOTES & SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. uIENERAL NOTES 1. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL VISIT THE JOB SITE TO THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING FIELD COND111ONS AND PHYSICAL CONSTRAINTS ASSOCIATED WITH THE WORK TO BE ACCOMPLISHED UNDER THIS CONTRACT, 2. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS: FLORIDA MECHANICAL CODE, FLORIDA ENERGY CODE, NFPA 90A STANDARDS FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, SMACNA DUCT CONSTRUCTION STANDARDS, ASHRAE 62.1 3. VERIFY FINAL LOCATIONS FOR ROUGH -INS WITH FIELD MEASUREMENTS AND WITH REQUIREMENTS OF THE ACTUAL EQUIPMENT TO BE INSTALLED. 4. COORDINATE THE CUTTING AND PATCHING OF BUILDING COMPONENTS TO ACCOMMODATE THE INSTALLATION OF HVAC EQUIPMENT AND MATERIALS. 5. PROVIDE WEATHER PROTECTION FOR ALL, EQUIPMENT AND MATERIALS STORED ON SITE. 6. VENTILATION DUCTWORK SHALL BE SHEET METAL AND INSTALLED IN ACCORDANCE WITH SMACNA. ALL OTHER DUCTWORK MALL BE AS SHOWN ON THE PROJECT PLANS. DUCTWORK INSULATION SHALL COMPLY WITH THE FLORIDA ENERGY CODE. 7. REFER TO ELECTRICAL OILING GRID LIGHTING PLAN FOR EXACT LOCATION OF AIR DISTRIBUTION DEVICES 8. PROVIDE ALL DUCT TRANSITIONS REQUIRED TO CONNECT EQUIPMENT SHOWN TO DUCT SYSTEMS. 9. PROVIDE DUCT MOUNTED SMOKE DETECTORS ON 'THE SUPPLY OF ALL AIR HANDLING SYSTEMS 2000 CFM AND GREATER. 10. MECHANICAL EQUIPMENT ON ROOF OR ELEVATED STRUCTURES SHALL COMPLY WITH FMC-2020 SEC. 306.5 & FBC-2020 SEC. 1510.10. MECHANICAL EQUIPMENT INSTALLED IN ATTICS / ABOVE CEILINGS SHALL COMPLY WITH FMC-2020 SEC. 306.3. 11. MECHANICAL EQUIPMENT, APPLIANCES & SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED & INSTALLED TO RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH FBC-BUILDING. ALL WIND LOAD & OTHER COMPLIANCE CALCULATIONS AND / OR INSTALLATION DETAILS FOR ROOF MOUNTED EQUIPMENT AS REQUIRED BY FBC-2020 SEC. 1510, 152.2, & CHAPTER 16 SHALL BE PROVIDED BY STRUCTURAL ENGINEER / ARCHITECT. CONTRACTOR TO PROVIDE WIND LOAD CALCULATIONS SIGNED & SEALED BY A FLORIDA REGISTERED STRUCTURAL ENGINEER FOR NON PRE -APPROVED CONFIGURATIONS DEVIATING FROM THE ORIGINAL CONSTRUCTION DOCUMENTS. 12. CONTRACTOR SHALL PATCH & REPAIR EXISTING ROOFING MATERIAL AS REQUIRED BY AN APPROVED ROOFING CONTRACTOR FOR ROOFING MEMBRANE ORIGINALLY INSTALLED SO AS TO NOT VOID WARRANTY. CONTRACTOR IS TO PROVIDE REQUIRED STRUCTURAL STEEL FRAMEWORK FOR ADD11IONAL SUPPORT. CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING A STRUCTJRAL ENGINEER FOR SIZING OF STRUCTURAL STEEL FRAMEWORK REQUIRED. 13. CLEARANCE FOR MAINTENANCE, SERVICE, REPAIRS & REPLACEMENT FOR ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED TO COMPLY WITH FMC-2020 SEC. 306. SERVICE ACCESS PANELS FOR MECHANICAL EQUIPMENT IN CONCEALED SPACES SHALL BE PROVIDED TO COMPLY WITH THE REQUIREMENTS OF SEC. 306. 14. PROVIDE AIR BALANCE TO QUANTITIES SHOWN ON THE PLANS. PROVIDE ALL VOLUME DAMPERS REQUIRED TO ACCOMPLISH AIR BALANCE. --SUBMIT BALANCE REPORT FOR REVIEW 15. SYSTEM TEST & BALANCE REPORT (PREPARED BY SEPARATE 3RD PARTY AABC/NEBB CERTIFIED T&B CONTRACTOR) TO BE INCLUDED WITH INSTALLATION. PROVIDE REPORT TO OWNER AND ENGINEER FOR RENEW. INSTALLATION WILL NOT BE CONSIDERED COMPLETE WITHOUT T&B REPORT. HVAC CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY VOLUME' DAMPERS, EQUIPMENT, ADJUSTMENTS, ETC. REQUIRED TO ACHIEVE SATISFACTORY T&B RESULTS. 16. THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ENGINEER'S DESIGN CONCEPT. THEY ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. ELECTRICAL CONNECTION NOTES 1. COORDINATE POWER WIRING AND CONDUIT FROM PANEL THRU FUSED DISCONNECT TO UNIT WITH ELECTRICAL. 2. COORDINATE THE FUSED DISCONNECTS WITH ELECTRICAL. 3. MAKE FINAL CONNECTIONS TO AIR HANDLING UNIT WITH "GREENFIELD". MAKE FINAL CONNECTION TO CONDENSING UNIT WITH "LIQUIDTITE". FINAL CONNECTIONS SHALL BE A MINIMUM OF 3 FT. 4. ALL WIRING SHALL BE COPPER. SEE ELECTRICAL DRAWINGS FOR WIRE SIZE. 5. CONTROL WIRING SHALL BE RUN IN CONDUIT. 6. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTROL WIRING. 7. AIR HANDLING UNIT SHALL BE PROVIDED WITH SINGLE POINT OF ELECTRIC ENTRY. 8. MECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTER AND HEATER CONTACTORS IN CONTROL PANEL. EXHAUST FAN SCHEDULE MECHANICAL DRAWING INDEX SYMBOL DESCRIPTION SHEET DESCRIPTION ISSUED EF-I GREENHECK BELT DRIVE 24" SIDEWALL EXHAUST FAN, SBE-3H24-10 I HP 230/lo/60HZ, MINIMUM 5000 CFM M-1 HVAC GENERAL NOTES, SYMBOLS, SCHEDULES a DETAILS YES 0 0.5N WG. PROVIDE WALL HOUSING W/GUARD a DAMPER. INSTALL PER MANUFACTURER'S M-2 MECHANICAL HVAC PLAN YES RECOMMENDATIONS. INTERLOCK W/ CREMATORY OPER. SUPPLY FAN SCHEDULE SYMBOL DESCRIPTION SF-1 GREENHECK BELT DRIVE 240 SIDEWALL SUPPLY FAN, SBS-3H24-10 I HP 230/lo/60HZ, MINIMUM 5000 CFM o 0.5" WG. PROVIDE WALL HOUSING W/GUARD, DAMPER a WALL LOUVER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. INTERLOCK W/ CREMATORY OPER. a a U U 0 I Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a .o Ld ao w LL- a - z <L o w aw LFL:LJ � w co�� ::! oo'- U CD LL n O z W J a _0 U J zo < o LL z WLd o J U Z, 0 _W W Q U Ov EL w O F'' o ENGINEER SEAL 3. SVO,& 0982 0 2-1 f -A•; STAT OF a 40 Z. P� O• • F•• . < O R 10. '• �� S• .•••••••• • G� /11111111100, Eric J. Svoboda, PE P.E. No. 60982 TMSE DM10n, &M WM TIE COA;EPTS NM M DESIW PRESDM HDaM ARE D1IENDEO MLY RE THE S VZX PURPOSE NO aM f Ci FMT PIERCE DEDMDE, D7C. FM YHICH M VERE PREPARED. REUSE M DP"M RELDNCE a ME DOCI"n VMWT MUM AUTI♦DMUN NO ADAPTAUM BY F WT PMU ENG CUM, INC. SHALL X WMH LIANLM M THE SANE C6'YRIGHT©2021, FORT PMZM DUMBE, INC. ALL RIGHTS RESERVED. SHEET TITLE HVAC GENERAL NOTES, SYMBOLS & SCHEDULES ISSUE DATE: 03-17-2021 DRAWN: EJS APPROVED: EJS DRAWING NUMBER e SHEET I OF 2 21001-03 GENERAL NOTES: I. PROVIDE NEW SIDEWALL EXHAUST / SUPPLY FANS AS INDICATED - INTERLOCK ALL EF-I / SF -I FAN OPERATION WITH CREMATORY UNITS - FANS SHALL ACTIVATE WHEN EITHER CREMATORY IS IN USE. 2. COMBUSTION AIR PROVIDED BY FAN OPERATION DURING EQUIPMENT OPERATION. 3. SEE ARCHITECTURAL PLANS FOR MANUFACTURER PROVIDED EQUIPMENT EXHAUST STACK ROOF PENETRATION DETAILS. KEY NOTES: IO 24'x24' EXHAUST OR SUPPLY FAN HIGH IN WALL. FIELD COORDINATE EXACT INSTALLATION LOCATION BASED ON STRUCTURE. INTERLOCK OPERATION WITH CREMATORY UNITS. 2O PROVIDE 24'x24N IMPACT RATED LOUVER WITH RAINSTOPS 6 GUTTERS. INSTALL PER MANUFACTURERS REQUIREMENTS. VERIFY FAN AIRFLOW WILL NOT BE IMPACTED BY PRESSURE DROP ACROSS LOUVER. 30 HATCHED AREAS ARE EXISTING 8E NOT IN SCOPE OF WORK. 4O HIGH BAY DOOR OPEN DURING OCCUPIED PERIODS. OUTDOOR AIR CALCULATIONS WAREHOUSE 2870 SO. FT. x 0.06 CFM = 172.2 CFM O.A. 5 PPL x 10 CFM = 50 CFM O.A. COMBUSTION AIR TOTAL CREMATORY GAS INPUT = 14.400,000 BTU TOTAL GAS INPUT FOR NEW SPACE = 14,400,000 BTU PER FBC FUEL GAS 304.9 MECHANICAL COMBUSTION AIR SUPPLY; 0.35 CFM REQUIRED PER 1,000 BTU. 14,400,000 / 1,000 = 14,400 14,400 X 0.35 = 5040 CFM REQUIRED. 10,000 CFM SUPPLIED VIA SIDEWALL SUPPLY AND EXHAUST FANS. NOTE - FANS SHALL BE INTERLOCKED WITH CREMATORY OPERATION. TOTAL O.A. REQUIRED = 5,262.2 CFM. 10,000 CFM O.A. PROVIDED. SCHEDULEEQUIPMENT fiER EQUIPMENT DESCRIPTION PP It CREMATORY 2 BLP 500 CREMATORY HE0n G UNIT 0 z 0 w w a 0 A Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 Q .o Lu Qo ww z aw o aw w w0- w LOQ�rn J co � M U F--1 w J U a tro LL z 0 w w O U J 0 W U vo F- w OF", o 0) Lr � W 0-1 a- n o a - ENGINEER SEAL �IIIIII ���� SV / // Oe0 * �. No: 982 0 . _ . A E1'21000 �= JOF Z .p. .<v. Eric J. Svobodo, PE P.E. No. 60982 TIESE noClAEM, &m vml TTE apmTs Na IR BMW PRESEMU H EM ARE MOM GN.Y RR UE SPECff7C WAtWISE Alm CLENI OF nRT PUM ENG CONG, V- FM W= THEY NEW PREPARED. REUSE M DA'OU RELIANCE M THESE DOCUE m Mw YRITTEN AU1 UMTEM Na ADAPIATM BY r PIERCE ENGQEM G, V- SHALL x VITFalI LLIBIIITY TO TEE SAME MRfffIT0 8M flw PERCE DoEww" W. ALL RII n RESERVED, SHEET TITLE HVAC PLAN SSUE DATE: 03-17-2021 DRAWN: EJS APPROVED: EJS DRAWING NUMBER M-2 SHEET 2 OF 2 21001-03 GAS SERVICE BY GAS CO. PREVIOUS LOAD 6,000 MBH TOTAL NEW LOAD = 17,400 MBH ,I , FLU **zy MBING GAS PLAN SCALE 1/4" = I'-C" GENERAL NOTES: I. PROVIDE NEW GAS LINE a CONNECTIONS AS INDICATED. ROUTE GAS PIPE HIGH WITHIN SPACE THEN DOWN TO EQUIPMENT. KEYNOTES: OI GAS CO. TO PROVIDE NEW GAS LINE FROM EXISTING METER AS INDICATED. GAS SERVICE SIZE TO BUILDING SHALL BE EVALUATED BY GAS. CO. 2O ROUTE NEW 2" GAS LINE THRU WALL & UP WITHIN SPACE - ROUTE OVERHEAD TO EQUIPMENT AS INDICATED. 30 ROUTE I 1/4" GAS LINE DOWN TO EQUIPMENT. 4O ROUTE 2" GAS LINE DOWN TO EQUIPMENT. 50 PROVIDE 2ND STAGE REGULATOR ADJUSTABLE TO 11" WC AND SHUT-OFF VALVE PER CREMATOR EQUIPMENT MANUFACTURER REQUIREMENTS. © PROVIDE 2ND STAGE REGULATOR ADJUSTABLE TO 14" WC AND SHUT-OFF VALVE PER CREMATOR EQUIPMENT MANUFACTURER REQUIREMENTS. 0 CONNECT GAS TO EQUIPMENT PER MANUFACTURER REQUIREMENTS. ® ROUTE IN PVC VENT LINE FROM REGULATOR HIGH IN SPACE & THRU EXTERIOR WALL - TERMINATE LINE FACING DOWN AT WALL EXTERIOR. EQUIPMENT I U BER_F_RW'MENT DESCRIPTION f PP U CREMATORY SHELVING UNIT PROCESSOR SPECIALIZATION PAW PRINTS MCI - CREMATORY w a 0 0 Z Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 O i--I z U J U a a-,o J < o U o z0 LLJ Uj 0 0 F- -� g w W w ov a O a)�- o' W af ti o ENGINEER SEAL G j• '& I/ SVO�� O i * : 0982 • 13 , STATE OF ; � P i 40��S •. < O R �.O ••' 00 � Eric J. Svoboda, PE P.E. No. 60982 THESE DDM "n, &W WITH DE rxrHCEM AND at DLTm PRESE M HEREIN ARE 1NIt7lOED DN.Y FM TIE SPE M PIN W NM MW W MU PD: M ENGOmtDIG, INC. FM WHM THEY WERE PREPARED. REUSE DR WRM RELIANCE DN THESE DDpDEMS W RW WRITIETt AUTHD MTn AN ADAPTATRN BY nW MIU niGBEERBiG, M SHALL BE WET W LWLM III THE SNE, CDPYWff ©2M FDRT PIERCE 0"EMM, V_ ALL RlTM WM WM SHEET TITLE PLUMBING GAS PLAN ISSUE DATE: 03-17-2021 DRAWN: EJS APPROVED: EJS DRAWING NUMBER P-2 SHEET 2 OF 2 21001-03 ELECTRICAL SYMBOL LEGEND SPEC IF IC4 TIONST TELEPHONE/DATA SYSTEM FIRE ALARM/DETECTION SYSTEM SYMBOL DESCRIPTION SYMBOL DESCRIPTION PHONE/DATA OUTLETS MOUNTED AT RECEPTACLE MANUAL PULL STATION HEIGHT UNLESS OTHERWISE NOTED. C = ABOVE THE COUNTER CEILING SMOKE DETECTOR, PHOTOELECTRIC M = NUMBER OF DATA PORTS, DEFAULT = I ® TYPE UNLESS OTHERWISE NOTED N = NUMBER OF PHONE PORTS, DEFAULT = I mA 8P8C E = ELEVATOR WITH RECALL CONTACTS DATA OUTLET, I = IONIZATION N PHONE OUTLET, RJ II DUCT SMOKE DETECTOR, SIMPLEX 4098-9686 OR EQUAL SA = SIMPLEX 4098-9687 OR EQUAL M N COMBINED DATA/PHONE OUTLET, 8P8C/RJII ® SUPERVISED CONTROL RELAY ® TELEPHONE OUTLET FLOOR MOUNTED DUCT DETECTOR REMOTE ALARM INDICATOR AND, TEST STATION, WALL MOUNTED 72' AFF, TTB SIMPLEX 4098-9835 OR EQUAL TELEPHONE/COMPUTER TERMINAL BOARD rrrrrrrrrrrrrrrrrrmDUCT DETECTOR REMOTE A/V CONTROL STATION oC WITH TEST SWITCH, WALL MOUNTED 72' AFF, TELEPHONE TERMINAL CABINET SIMPLEX 4098-9842 OR EQUAL /-T-"\ TELEPHONE SYSTEM RACEWAY X COMBINATION AUDIBLE/VISUAL CD NOTIFICATION DEVICE CD = CANDELA RATING, MINIMUM 75 CD PER TELEVISION RACEWAY SYSTEM FBC II-4.28.3(4) SS FIRE ALARM SPEAKER - CEILING MOUNTED WALL MOUNTED SPEAKER WITH ,STROBE TELEVISION OUTLET FOR ANTENNA XXCD CD = CANDELA RATING TV TELEVISION SIGNAL WALL OUTLET 11_---TV--_,,,, TV DISTRIBUTION SYSTEM RACEWAY FIRE ALARM SPEAKER - WALL MOUNTED ❑M MAGNETIC LOCK O FIRE ALARM SPEAKER WITH STROBE - CEILING MOUNTED CCTV CAMERA W/ CONDUIT TO VIDEO CD = CANDELA RATING JUNCTION BOX VISUAL SIGNALING UNIT, WALL MOUNTED PTZ PAN/ TILT/ ZOOM CCTV CAMERA W/CONDUIT (NO AUDIO DEVICE) TO VIDEO JUNCTION BOX - MOUNTED MIN 15' FIREMAN'S PHONE JACK AFF OR 0 CEILING SPRINKLER TAMPER SWITCH CONNECTION SYNCHRONOUS MASTER CLOCK SYSTEM FS SPRINKLER WATER FLOW SWITCH CONNECTION SYNCHRONOUS SYSTEM CLOCK FP FIRE: ALARM SYSTEM PRINTER FATC MASTER CLOCK CONTROL PANEL 0 - q� ZONE ADDRESSABLE MODULE ® ELECTROMAGNETIC DOOR HOLD OPEN DEVICE MASTER CLOCK SYSTEM CONDUIT AND WIRING ,,--CL--,, ®H ELECTROMAGNETIC DOOR HOLD OPEN DEVICE CONNECTION TO CLOSURE/ HOLDER DOORBELL SYSTEM 19 ELECTROMAGNETIC DOOR HOLD OPEN DEVICE H O CONNECTION TO CLOSURE/ HOLDER INCLUDES DETECTOR CEILING HEAT DETECTOR 135 F UNLESS OTHERWISE -!� DOOR PUSH-BUTTON STATION WP = WEATHERPROOF INDICATED. DB DOORBELL CHIME (SELF CONTAINED) 114 BEAM DETECTOR - TRANSMITTER ®� BEAM DETECTOR - RECEIVER -DB-� DOORBELL SYSTEM CONDUIT AND WIRING FACP o FIRE- ALARM CONTROL PANEL Fo FIRE -ALARM TERMINAL CABINET DOOR CONTROL SYSTEM FAAP FIRE ALARM ANNUNCIATOR PANEL - FLUSH MOUNTED MO MOTION DETECTOR 360 F \ FIRE ALARM SYSTEM CONDUIT AND WIRING ® CARD READER - EQ FIRE:MAN`S ELEVATOR WARNING LIGHT K❑ DIGITAL KEYPAD BALANCED MAGNETIC DOOR CONTACT KK KNOX BOX -LOCATION TO BE COORDINATED WITH THE AHJ PAGING SYSTEM & BACKGROUND MUSIC INTERCOM SYSTEM - LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ IC MASTER STATION SUPPORT TRUSS.. (CEILING MOUNTED) W :- WALL MOUNTED C =COUNTER D = DESK LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ W = WALL MOUNTED ENCLOSURE FOR EXPOSED CEILING AREAS H = HAND SET TYPE W :- WALL MOUNTED HF = HANDS FREE WP = WEATHER PROOF MI HORN/TRANSFORMER FOR HIGH NOISE AREAS IC INTERCOM SYSTEM SPEAKER W = WALL MOUNTED Po _ PAGING SYSTEM EQUIPMENT CAE'IINET ICCEEC INTERCOM EQUIPMENT CABINET PATC o _ PAGING SYSTEM TERMINAL CABINET ICCTTC INTERCOM TERMINAL CABINET CDR--� DOCTORS REGISTRY SYSTEM CONDUIT AND WIRING �- IC INTERCOM SYSTEM CONDUIT AND WIRING VC VOLUME CONTROL SSEE:;M SOUND SYSTEM EQUIPMENT CABINET GFCI DEAD FRONT/BLANK FACED, WHITE GFCI DEVICE. EATON # SGFD20 W. MOUNTED AT 48' AFF OR EQUAL So SOUND SYSTEM TERMINAL CABINET CONTROLLED RECEPTACLE. BREAK OUT TAB FOR SPLIT OPERATION. SHALL BE MARKED IN FIELD PER 406.3(E). S-� BOTTOM RECEPTACLE TO BE CONTROLLED SOUND SYSTEM CONDUIT AND WIRING SDMS PASSIVE INFRARED, 0-IOV DIMMING WALL SWITCH/OCCUPANCY SENSOR WATTSTOPPER # PW-3IIOW BASIC MATERIALS SYMBOL DESCRIPTION Sa SINGLE POLE SWITCH (SUBSCRIPT INDICATES ITEM CONTROLLED) S3 THREE-WAY SWITCH S4 FOUR-WAY SWITCH SD DIMMER SWITCH (1500 WATTS UNLESS OTHERWISE INDICATED) SF CEILING WHITE FAN/LIGHT CONTROL, DAN'S FAN CITY #423LW OR EQUI OLOR SK SINGLE POLE KEY SWITCH SY THREE-WAY KEY SWITCH S4K FOUR-WAY KEY SWITCH SL SINGLE POLE SWITCH WITH SECURITY LOCKING KEY SLV LOW VOLTAGE SWITCH SM MOTOR RATED SNAP SWITCH, IHP MIN., 20A, 120/277V LEVITON 1121-2 OR EQUAL SMp MANUAL MOTOR STARTER WITH OVERLOAD HEATERS AND PILOT LIGHT Sp SINGLE POLE SWITCH WITH PILOT LIGHT SR SINGLE POLE SWITCH CONTROLLING SWITCHED RECEPTACLE STD SINGLE POLE SWITCH - TIME DELAY FOR EXHAUST FAN/LIGHTS SWp SINGLE POLE SWITCH WITH WEATHERPROOF COVER SWST SPRING WOUND WALL SWITCH TIMER (30 MIN.) (9�= DUPLEX RECEPTACLE, 5-20R UNLESS OTHERWISE NOTED Tom- SINGLE 5-20R RECEPTACLE, T DENOTES TWIST -LOCK GFCI DEAD FRONT/BLANK FACED, WHITE GFCI DEVICE. EATON # SGFD20 W. MOUNTED AT 48' AFF OR EQUAL SURGE PROTECTION TYPE (TVSS) SP DUPLEX RECEPTACLE ® PEDESTAL MOUNTED RECEPTACLE ® FLOOR OUTLET BOX AND DUPLEX RECEPTACLE WITH APPROPRIATE FLANGE. FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE ® AND ONE COMBINATION W/ VOICE/DATA OUTLET ® FLOOR OUTLET BOX WITH TWO DUPLEX RECEPTACLES AND ONE COMBINATION W/ VOICE/DATA OUTLET © POKE THRU PP POWER POLE SINGLE POLE SWITCH/RECEPTACLE COMBINATION S DUPLEX RECEPTACLE WITH EACH HALF ON SEPARATE CIRCUIT (BREAKER SHALL BE TWO POLE WITH COMMON TRIP) DUPLEX RECEPTACLE MOUNTED ABOVE. COUNTER DUPLEX TAMPER -RESISTANT RECEPTACLE. MOUNT COVER PLATE WITH SPANNER HEAD SCREWS DUPLEX RECEPTACLE WITH TOP HALF SWITCHED GFCI RECEPTACLE (EWC DENOTES ELECTRIC EWC WATER COOLER. COORDINATE WITH EWC INSTALLER FOR MOUNTING HEIGHT) WPC GFCI RECEPTACLE. WP DENOTES WEATHERPROOF COVER. @9-- GFCI RECEPTACLE MOUNTED ABOVE COUNTER GFCI DEAD-FRONT/BLANK FACE GFCI, EATON SGFD20 OR EQUAL TWO DUPLEX RECEPTACLES WITH COMMON COVER TWO DUPLEX RECEPTACLES WITH COMMON COVER MOUNTED ABOVE COUNTER C- CONTROLLED RECEPTACLE. BREAK OUT TAB FOR SPLIT OPERATION. SHALL BE MARKED IN FIELD PER 406.3(E). �Qt= ISOLATED GROUND DUPLEX RECEPTACLE, IG (ORANGE DEVICE) DUPLEX RECEPTACLE NOTE: TICK MARKS SHOWN ON ANY DEVICE REPRESENTS RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT (RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND ® SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED ASTRONOMIC TIME SWITCH ABLE TO RETAIN CE] PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER FOR A PERIOD OF AT LEAST 10 HOURS. ® PHOTOCELL, MOUNTED ON ROOF FACING NORTH ® GROUND BAR ® PLUG-IN STRIP WITH RECEPTACLES, 18' O.C. UNLESS OTHERWISE INDICATED ® UNDER GROUND CONCRETE ENCASED DUCTBANK (D JUNCTION BOX -� JUNCTION BOX- WALL MOUNTED JUNCTION BOX- FURNITURE SYSTEM FEED ■ CONDUIT SEAL -OFF FITTINGS SURGE PROTECTIVE DEVICE C3 C3 = TYPE I, NEMA 4X, CITEL MDS300 OR EQUAL B3 = DISTRIBUTION BOARD DEVICE, SEE RISER FOR RATING A3 = PANEL BOARD DEVICE, MAX 125KA PER PHASE ST SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS ED,�� ELECTRIC DUCT HEATER I[JMOTOR CONNECTION ® VARIABLE FREQUENCY DRIVE FH_D_1 ELECTRIC HAND DRYER ®D DIRECT DIGITAL CONTROL PANEL T❑ TRANSFORMER NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. BASIC MATERIALS CON'T. S'YMBOL DESCRIPTION PA AUTOMATIC TRANSFER SWITCH E,/T NON -FUSED DISCONNECT SWITCH, AMP RATING / # OF POLES NEMA I IF INDOORS NEMA 313 IF OUTDOORS I 30AR FUSED DISCONNECT 20AF AR DENOTES AMP RATING OF SWITCH AF DENOTES AMP FUSE SIZE MCP DENOTES FUSE PER MANUFACTURER RECOMMENDATIONS SIZE # OF POLES ®1 30/3 3R COMBINATION MAGNETIC MOTOR STARTER, SIZE a # OF POLES 0 3 POLE UNLESS OTHERWISE NOTED ENCLOSURE NEMA RATING. NEMA STARTER SIZE -�� BRANCH CIRCUIT PANEL BOARD, UNDER 250 VOLTS, SURFACE MOUNTED �C BRANCH CIRCUIT PANEL BOARD, UNDER 250 'VOLTS, FLUSH MOUNTED BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, SURFACE MOUNTED BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, FLUSH MOUNTED BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. ,,,----,,,CONDUIT SHALL INCLUDE PHASE, NEUTRAL A14D GROUND CONDUCTORS AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, UNDERGROUND OR UNDER FLOOR. BRANCH CIRCUIT CONDUIT EXPOSED I�- GROUND OR GROUND ROD AS NOTED EMERGENCY BRANCH CONDUIT -SUP CONDUIT TURNING UP -�DN CONDUIT TURNING DOWN -- ] CONDUIT STUB --2 CONDUIT CONT"HUED FLEXIBLE CONDUIT EXISTING TO BE REMOVED EXISTING TO REMAIN -- EXISTING AFFECTED BY THIS PROJECT -- - FUTURE ®� NEW LIGHTING F- 0o 1 LINEAR OR STRIP FIXTURE FIXTURE -A DESIGNATION ® LAY -IN TROFFER FIXTURE CIRCUIT- 2 a- LOWER CASE LETTER INDICATES LIGHTING CONTROL NUMBER LAY -IN TROFFER FIXTURE DIAGONAL. SHADING DENOTES EMERGENCY LIGHT FIXTURE. WRAP AROUND OR SURFACE MOUNTED (FIXTURE. WALL MOUNTED VANITY OR CLOSET FIXTURE ' EXTERIOR WET LOCATION WALL MOUNTED FIXTURE 0 CEILING OR SOFFIT MOUNTED DOWNLIGHT FIXTURE Q PENDANT OR BAY FIXTURE (> WALL WASH FIXTURE �- ACCENT FLOOD LIGHTING - AIMING AS INDICATED EXIT LIGHT FIXTURE ® DIRECTION ARROWS AS SHOWN (SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) H8 WALL MOUNTED EXIT LIGHT FIXTURE $14 COMBINATION EXIT/EMERGENCY LIGHT FIXTURE W/REMOTES 0-0 POLE MOUNTED AREA LIGHT FIXTURE WITH ARMS AS SHOWN ON DRAWINGS PB ELECTRICAL PULL BOX TRACK WITH TRACK LIGHT FIXTURE (TRIANGLES INDICATE QUANTITY OF LIGHT FIXTURES) ® BATTERY PACK WITH TWIN HEADS (CEILING MOUNT) BATTERY PACK WITH TWIN HEADS (WALL MOUNT) LIGHTING CONTROL SYSTEM -PLC LIGHTING CONTROL PANEL S A WALL -MOUNTED, MANUAL ON/OFF SWITCH AND AUTOMATIC OFF OCCUPANCY SENSOR SP WALL -MOUNTED, ON PULSE / OFF PULSE BUTTON Co TIME SWITCH CONTROL PER FBC C405.2.2.1. is INDEPENDENT 7-DAY PROGRAMMING HOLIDAY SETTING, 10 HOUR PROGRAM 13ACKUP TWO-HOUR MANUAL OVERRIDE MODE. INTERMATIC ET2800 SERIES OR EQUAL D❑ PASSIVE INFRARED / ULTRASONIC OCCUPANCY SENSOR C = CEILING MOUNT W = WALL MOUNT ® DAYLIGHT SENSOR SMS SINGLE POLE SWITCH - PASSIVE INFRARED OCCUPANCY SENSOR ® LIGHTING ROOM CONTROLLER/POWER SUPPLY I. THE TOTAL ELECTRICAL INSTALLATION MUST MEET THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA ADMINISTRATIVE CODE (FAC), SECTION 61GI5-33, AND, BY REFERENCE IN THE FAC, THE FLORIDA BUILDING CODE, 7TH EDITION, (2020), THE FLORIDA FIRE PREVENTION CODE, 7TH EDITION, (2020), AND THE 2017 EDITION OF NFPA 70, THE NATIONAL ELECTRICAL CODE. 2. ON ALL ELECTRICAL PLAN SHEETS, E.G. 'E-I', 'E-2.1', ETC., THE TERM 'CONTRACTOR' SHALL MEAN 'ELECTRICAL CONTRACTOR', SOMETIMES ALSO ABBREVIATED AS 'E.C.'. 3. MATERIALS AND EQUIPMENT INSTALLED SHALL BE ENTIRELY NEW, UNLESS OTHERWISE NOTED, AND SHALL BE LISTED BY UNDERWRITERS LABORATORIES. 4. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. 5. CONTRACTOR TO INSTALL ELECTRICAL EQUIPMENT FOR LIGHTING AND POWER FROM THE EXISTING BRANCH -CIRCUIT PANELS TO AND INCLUDING ALL EQUIPMENT SPECIFIED ON THESE PLANS AND EQUIPMENT FURNISHED BY OTHERS AS MAY BE REQUIRED. 6. SERVICE EQUIPMENT SHALL BE MARKED WITH THE MAXIMUM AVAILABLE FAULT CURRENT AMPERES ('FCA') PER NEC 110.24 AND THE DATE OF THE MARKING. SEE RISER DIAGRAM SHEET E-4 FOR FAULT CURRENT CALCULATED VALUES. 7. UNLESS OTHERWISE NOTED OR SHOWN ON THESE PLANS, 8.4 KV MCOV LINE -TO -NEUTRAL, 75KV BIL, 33.7KV CREST FRONT -OF -WAVE PROTECTIVE LEVEL, 65KA MINIMUM SHORT -DURATION WITHSTAND SURGE PROTECTION (TYPICAL) IS PROVIDED BY THE SERVING ELECTRIC UTILITY AT THE OVERHEAD TRANSFORMER OR PRIMARY RISER POLE SERVING THIS PREMISES. 8. CONTRACTOR TO COMPLETE ALL WORK INCIDENTAL TO MECHANICAL TRADES FOR A COMPLETE INSTALLATION, INCLUDING CONTROL WIRING, MOTOR STARTERS, DISCONNECT SWITCHES AND EQUIPMENT GROUNDS. 9. DEFERRED SUBMITTALS FOR ANY LOW VOLTAGE SYSTEMS SHALL BE SUBMITTED TO THIS ENGINEER AND TO THE BUILDING OFFICIAL PRIOR TO INSTALLATION. CONTRACTOR TO MAKE NECESSARY PROVISIONS FOR THE INSTALLATION OF ANY AND ALL SYSTEMS FOR THIS PROJECT, INCLUDING RACEWAYS, CABINETS, PULL BOXES AND OUTLETS. SEE SHOP DRAWINGS FOR EACH SYSTEM FOR ADDITIONAL DETAILS AND INSTRUCTIONS. 10. CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES COMPLETE AS LISTED IN THE 'LIGHTING FIXTURE SCHEDULE'. 11. PANELBOARDS, SWITCHBOARDS AND DISCONNECT SWITCHES SHALL HAVE COPPER OR COPPER (NOMINAL 15% BY VOLUME) CLAD ALUMINUM BUS. 12. ALL PANELS, DISCONNECTS, TIME CLOCKS, AND CONTACTORS SHALL BE LABELED WITH A PERMANENT ENGRAVED LABEL. IDENTIFICATION ON THE LABEL MUST CONFORM TO THESE ELECTRICAL DRAWINGS. 13. TYPEWRITTEN CIRCUIT IDENTIFICATION SHALL BE UPDATED IN ALL PANELBOARDS, EACH BREAKER HAVING A DISTINCTIVE DESCRIPTION COMPLYING WITH NEC 408.4(A). ALL PANELBOARDS SHALL BE MARKED WITH THEIR SOURCE OF SUPPLY PER NEC 408.4(B). 14. CONDUIT FOR UNDERGROUND SHALL BE SCHEDULE 40 PVC OR MC CABLE LISTED FOR UNDERGROUND USE UNLESS OTHERWISE SHOWN AND/OR REQUIRED BY CODE. UNDERGROUND CONDUITS SHALL BE INSTALLED AT A DEPTH IN ACCORDANCE WITH TABLE 300.5. 15. CONDUIT FOR ABOVE GRADE SHALL BE 'GRC', 'IMC' OR 'EMT'. 'LFNC' SHALL BE USED FOR CONNECTIONS TO AIR HANDLING UNITS, CONDENSING UNITS, WATER HEATERS AND OTHER EQUIPMENT. MC CABLE MAY BE USED FROM 'J-BOXES' IN CEILING, OR, WHEN STUDS OR OTHER POINTS OF SECURE SUPPORT NOT GREATER THAN 6 FEET APART ARE AVAILABLE, FROM BRANCH -CIRCUIT PANELS TO SWITCHES, RECEPTACLES AND BETWEEN DEVICES. SPARE CONDUITS SHALL HAVE A PULL WIRE INSTALLED. 16. CONDUCTORS SHALL BE THHN/THWN EXCEPT WHERE SPECIFIED OTHERWISE ON THE DRAWINGS. CONDUCTORS NO. 8 AWG AND LARGER SHALL BE JOINED BY AN APPROVED PRESSURE CONNECTOR. CONNECTION TO GROUND CONDUCTORS NO. 1/0 AWG AND LARGER SHALL BE CAST BY FUSIBLE METAL PROCESS. ALL CONDUCTORS MUST BE INSTALLED IN CONDUIT, MC CABLE, OR LFNC. CONDUCTORS IN PANELS SHALL HAVE THEIR FACTORY LABELS VISIBLE TO A PERSON IN THE WORKING SPACE. 17. CONDUCTORS OF MULTIWIRE CIRCUITS SHALL BE GROUPED IN AT LEAST ONE LOCATION WITHIN THE PANELBOARD OR OTHER POINT OF ORIGIN BY WIRE TIES OR SIMILAR MEANS PER 200.4(B). MULTIWIRE CIRCUIT DISCONNECTS SHALL BE PROVIDED WITH A MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES. 18. NO CONDUCTORS SMALLER THAN 12 AWG SHALL BE USED FOR POWER AND LIGHTING. ALL CONDUCTORS SHALL BE COPPER, UNLESS NOTED OTHERWISE. 19. COLOR CODE FOR 120/240V 3o SYSTEM SHALL BE: BLACK, RED, WHITE, a GREEN. 20. CONTRACTOR SHALL VERIFY WITH ARCHITECT FOR DETAILED DIMENSIONS AND LOCATIONS OF OUTLETS AND EQUIPMENT AND FOR ANY REVISIONS IN LAYOUT. 21. MOUNT WALL SWITCHES 44' ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON DRAWING. GANG SWITCHES WHEREVER POSSIBLE. 22. LIGHTING CONTROLS SHALL CONFORM TO THE REQUIREMENTS LISTED ON THE E-3 SERIES SHEETS IN THESE PLAP'S. CONTROLS SHALL BE WHITE OR IVORY IN COLOR. SWITCHES CONTROLLING LINE -TO -NEUTRAL LIGHTING LOADS SHALL COMPLY WITH NEC 404.2(C). 23. RECEPTACLEj SHALL BE LOCATED APPROXIMATELY 44' ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. ABOVE -COUNTER RECEPTACLES SHALL BE MOUNTED 6' ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. 24. COVER PLATES SHALL BE GALVANIZED STEEL, UNLESS OTHERWISE NOTED. RECEPTACLES WITH PLASTIC COVER PLATES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED DOWN, UNLESS OTHERWISE NOTED. RECEPTACLES WITH METAL COVER PLATES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP, UNLESS OTHERWISE NOTED. 25. ALL NEW 125V RECEPTACLES SHALL BE NEMA 5-20R, AND COLOR SHALL BE WHITE UNLESS NOTED OTHERWISE. RECEPTACLES SHALL BE EQUIPPED WITH BREAK OUT TAB FOR SPLIT OPERATION, AND CONTROLLED RECEPTACLES SHALL BEAR THE MARKING REQUIRED BY 406.3(E). A DUPLEX RECEPTACLE SHALL HAVE ITS BOTTOM OR RIGHT RECEPTACLE CONTROLLED. CONTROLLED RECEPTACLES SHALL BE POWERED BY STRIPED COLOR CODED WIRE. OUTDOOR RECEPTACLES SHALL COMPLY WITH 406.9(A) OR (B) AS APPROPRIATE TO CONDITIONS. GFCI TYPE RECEPTACLES SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. 26. CONTRACTOR SHALL CONNECT AIR CONDITIONERS, PUMPS, FANS AND OTHER EQUIPMENT. 27. AIR CONDITIONER BREAKER SHALL BE MARKED 'LISTED HACR TYPE" AS REQUIRED BY NEC 110.3(B). IF BREAKER IS NOT MARKED, THE OUTSIDE DISCONNECT SHALL BE CHANGED TO A FUSED DISCONNECT WITH RATING AS NOTED ON A/C EQUIPMENT. 28. CONTRACTOR SHALL MAKE TESTS AND ADJUSTMENTS AS REQUIRED, UPON COMPLETION OF THE WORK AND BEFORE FINAL ACCEPTANCE BY THE OWNER. THE CONTRACTOR SHALL TEST THE COMPLETE ELECTRICAL SYSTEM IN THE PRESENCE OF THE ENGINEER/ARCHITECT FOR CONTINUITY, FUNCTION, CONTROL, PERFORMANCE, LOAD BALANCE, GROUNDS AND GROUND RESISTANCE, SHORT CIRCUITS, AND TO INSURE SATISFACTORY OPERATION AND CONFORMANCE TO CONTRACT REQUIREMENTS. 29. EQUIPMENT, LABOR AND MATERIAL REQUIRED FOR TESTING SHALL BE FURNISHED BY THE CONTRACTOR(S) AS PART OF THIS CONTRACT. 30. PRIOR TO COMPLETION OF THE WORK, THE CONTRACTOR SHALL MARK THE SERVICE EQUIPMENT WITH THE AVAILABLE FAULT CURRENT PER NEC 110.24, USING EITHER THE FAULT -CURRENT FROM THE UTILITY FAULT CURRENT LETTER, OR THE SHORT CIRCUIT CURRENT CALCULATION FROM THESE PLANS. IF PROVIDED WITH THE FAULT CURRENT LETTER, THIS ENGINEER WILL UPDATE THE CALCULATION TO OBTAIN THE FAULT CURRENT AT THE SERVICE ENTRANCE. 31. AFTER COMPLETION OF THE WORK, THE CONTRACTOR SHALL SECURE CERTIFICATES OF FINAL INSPECTION AND APPROVAL FROM AUTHORITIES HAVING JURISDICTION (AHJ). 32. PER FBC C405.6.4.1, WITHIN 30 DAYS OF ELECTRICAL SYSTEM ACCEPTANCE BY THE AHJ, THE CONTRACTOR SHALL PROVIDE THE BUILDING OWNER WITH RECORD DRAWINGS OF THE ACTUAL INSTALLATION. THE RECORD DRAWINGS SHALL INCLUDE A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. IF PROVIDED WITH COMPLETE FIELD MARKUPS ON THESE PLAN SHEETS, THE ENGINEER SHALL MODIFY THESE PLAN SHEETS INTO SAID RECORD DRAWINGS AND PROVIDE A NOTE: TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020) AND THE FLORIDA FIRE PREVENTION CODE 6TH EDITION (2020). COPY TO THE OWNER AND TO THE CONTRACTOR AND RETURN THE ORIGINAL FIELD MARKUP TO THE CONTRACTOR. 33. PER FBC C405.6.4.2, WITHIN 30 DAYS OF ELECTRICAL SYSTEM ACCEPTANCE BY THE AHJ, THE CONTRACTOR SHALL PROVIDE THE BUILDING OWNER AN OPERATING AND MAINTENANCE MANUAL FOR ALL ELECTRICAL SYSTEMS INSTALLED IN ACCORDANCE WITH THESE PLANS THAT REQUIRE MAINTENANCE. AT A MINIMUM, THE MANUAL SHALL INCLUDE: A. EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. B. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. C. NAME AND ADDRESS OF AT LEAST ONE QUALIFIED SERVICE AGENCY. 41. WORKMANSHIP, MATERIALS AND APPARATUS UNDER THIS CONTRACT SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. 42. GREATER THAN 80% NONLINEAR LOADS: SHARED NEUTRALS AND GROUNDS ARE NOT PERMITTED FOR SINGLE PHASE CIRCUITS. 43. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110, AND WITH NEC 210.8 FOR 13FCI DEVICES. 44. THE EXCLUSIVELY -DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE PANEL BOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408. 45. WHEN ELECTRICAL BOXES ARE LOCATED IIN VERTICAL FIRE -RESISTIVE ASSEMBLIES, (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS AND FBC 714 SHALL BE MET: A. ALL ELECTRICAL BOXES SHALL BE METALLIC. B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. D. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THE: OUTLET BOX AND THE EDGES OF THE OPENING. E. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). F. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. G. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET OF WALL AREA. H. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE -RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. 1. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. ELE-CTRICAL ABBREVIATIONS AFF: ABOVE FINISHED FLOOR L: LIGHTING LOAD AFG: ABOVE FINISHED GRADE M: MOTOR LOAD BFC: BELOW FINISHED CEILING MBJ: MAIN BONDING JUMPER E.C.: ELECTRICAL CONTRACTOR MH: MOUNTING HEIGHT EGC: EQUIPMENT GROUNDING CONDUCTOR NL: NIGHT LIGHT F: FAN LOAD P: PANEL FCA: FAULT CURRENT AMPERES R: RECEPTACLE LOAD GC: GROUNDED CONDUCTOR SA: SMOKE/CO ALARM LOAD GEC: GROUNDING ELECTRODE CONDUCTOR SN: SOLID NEUTRAL GFI: GROUND FAULT CIRCUIT -INTERRUPTER UON: UNLESS OTHERWISE NOTED IG: ISOLATED GROUND VP: VAPOR PROOF WP: WEATHER PROOF ELECTRICAL DRAWING INDEX SHEET DESCRIPTION ISSUED E-1 ELECTRICAL LEGEND, SPECIFICATIONS 81 ABBREVIATIONS YES E-2 ELECTRICAL POWER SYSTEMS FLOOR PLAN YES E-3 ELECTRICAL LIGHTING SYSTEMS FLOOR PLAN YES E-4 ELECTRICAL RISERS SCHEDULES & DETAILS YES Z 0 w W Q 0 6 Z Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 Q 0 LLI QCC o ww � z a oQ _5w w EL ``' 0 0 V 00 LL In z O � w Q a Qo U J a o < o z W LL 0 Uj Li o J U 2 w W U D O w H D W o 0 ENGINEER SEAL C. T ���. •........ R� CE/Vscc•••GL.L f o. 61580 -I- STATE OF 0*000*0 Timothy C. Trewyn, PE P.E. No. 61580 THESE DOCIMn, &M VM THE COI Un AM OR DESIOG PRESENM HEW ARE WDW OLY FM TFE SPE TM ROM Arm CLIENT IF W PD:RCE DOEME, W. FM WHICH TWY VERE PREPARED. MM W W'MU RELTAHCE OH TFESE DOUMM VnH3H WRITTEN NJnU nffl arm ADAPTAUM BY FW PD:RCE DIGREERIHG, DW_ SHALL BE VMWT LIAMM TO TFE SW CD'YRtt} OMM, FW PMU DIGDMME, X_ ALL MM RESERVED. SHEET TITLE ELECTRICAL SYMBOL LEGEND, SPECIFICATIONS & ABBREVIATIONS ISSUE DATE: 03-17-2021 DRAWN: TEC APPROVED: TCT DRAWING NUMBER E-1 SHEET I OF 4 21001-03 U POWER SYSTEMS PLAN COOLER CONDENSER UNIT. COORDINATE FINAL ELECTRICAL REQUIREMENTS AND LOCAWN IN THE FIELD PRIOR TO ROUGH -IN. SCALE 114" = I'-O" ELECTRICAL DEMOLITION LEGEND SYMBOL DESCRIPTION <E> EXISTING TO REMAIN. <ER> EXISTING TO BE RELOCATED. <R> REMOVE AND TURN OVER TO OWNER. <ERP> EXISTING TO BE REPLACED. <ERC> EXISTING TO BE RECIRCUITED. <RE> RELOCATED, EXISTING FIRE ALARM SYSTEM NOTE: THIS FACILITY HAS OCCUPANCY CLASSIFICATIONS OF BUSINESS GROUP B AND FACTORY GROUP F-I WITH A SINGLE FLOOR AND WITH AN OCCUPANT LOAD OF LESS THAN 500 PERSONS. PER FBC 907.2.2 AND 907.2.4, A MANUAL FIRE ALARM SYSTEM IS NOT REQUIRED. ELECTRICAL KEY NOTES: QI COORDINATE THE ELECTRICAL REQUIREMENTS WITH THE CREMATORY SUPPLIER/INSTALLER PRIOR TO ROUGH -IN. ❑2 GFCI PROTECTED RECEPTACLES SHALL BE READILY ACCESSIBLE OR SHALL BE PROTECTED BY A GFCI CIRCUIT BREAKER IN THE PANEL. NLJMBERTEQtT1PMENT OESCRIPTIO PP It CREMATORY SHELVING UNIT ECIALIZATION PAW PRINTS WALK IN COOLER 0 S_1P6_ _G CREMATORY '2P I I EE— z Z 0 w w Q 0 I I I I I I I IZI Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a .o w� Qo w u- z aw U O Q rr W W W n W U O w IT J OD U_ rn U WP O vs W EXISTING p., J a EXHAUST FAN LJJ < o z a U w 0 LLI W w W H W O � 0 [� � rn ~ 12� W CL o � ro LL ENGINEER SEAL C. TOn . �. • ' 61580,E .� �• STATE OF tv ohs Ol•O"R I V. ee \��� •.....• G -0N i i %��`` Timothy C. Tr n, PE P.E. No. 610 TFESE BBGBEMS, AUM VirH TFE CMICEPM NO M BESM PRESOM TERM ARE NrENM mLY FM TIE SPECIFIC PIB' W Na CUEM W nW PIERCE DOEER A IRC. FM VIBCII M WERE PREPARM REUSE M BPRM 01.rARCE W TFESE DOCIAEMS VE Bff VRETTER NM W nM AIm ABAPTATM BY W PUM ErIGBEE M, W. SIWU. BE WMMT LTAEM m nE SATE. CCfYRrCiR©UM FW PEACE ENGBEEM BIG ALL RRMS RESERVm SHEET TITLE ELECTRICAL POWER SYSTEMS FLOOR PLAN ISSUE DATE: 03-17-2021 DRAWN: TEC APPROVED: TCT DRAWING NUMBER E-2 SHEET 2 OF 4 21001-03 a Y U CC 0 HAT ED ARfAS ARE NOT IN SCOPE OF WF ,4 P, uKy c, LIGHTING FIXTURE SCHEDULE MARK MANUFACTURER - PART NUMBER LAMPS VOLTAGE MOUNTING DESCRIPTION REMARKS NO TYPE WATTS A BEGHELLI - PEH-1 - LED 1.5 120 WALL 2 LAMP UL 97 V-0 PLASTIC EMERGENCY LIGHTING MOUNT 8'-0" A.F.F. FOR WALL MOUNT. B BEGHELLI - PEH-1 RC BRH-WP - LED 1.5 120 WALL 2 LAMP UL 97 V-0 PLASTIC EMERGENCY LIGHTING FIXTURE, REMOTE CAPABLE, MOUNT 8'-0" A.F.F. FOR WALL MOUNT. GENERAL LIGHTING FIXTURE SCHEDULE NOTE': I. VERIFY TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED. 2. VERIFY VOLTAGES PRIOR TO BID AND (INSTALLATION OF FIXTURES. 3. PROPOSED ALTERNATE LIGHTING BIDS MUST INCLUDE THE FOLLOWING: A. ORIGINAL AND ALTERNATE BID PRICES AND WARRANTIES SHALL BE PRESENTED BY THE VENDORS AND GENERAL CONTRACTOR TO THE OWNER. B. VENDOR SHALL PROVIDE PHOTOMETRIC LAYOUT OF PROPOSED ALTERNATE LIGHTING FIXTURES. IESNA LM-79 AND LM-80 TEST DATA MUST BE AVAILABLE FOR THE FIXTURE. C. ABOVE PHOTOMETRIC INFORMATION MUST BE SUPPLIED TO THE ENGINEER (3) DAYS PRIOR TO BID. 4. ALL COMPACT FLUORESCENT DOWNLIGHTS SHALL USE ELECTRONIC BALLASTS, UNLESS OTHERWISE NOTED. 5. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN FIRE RATED CEILINGS. 6. FIXTURES IN AREAS WITHOUT CEILINGS OR IN MECHANICAL AND ELECTRICAL ROOMS SHALL BE MOUNTED WITH I 1/2'xl 1/2' KINDORF CHANNEL SUPPORT SUSPENDED FROM ROOF STRUCTURE WITH THREADED RODS. FIXTURES SHALL BE MOUNTED 10'-01A.F.F. UNLESS OTHERWISE NOTED. 7. ALL ACRYLIC LENSED FIXTURES SHALL. HAVE A MINIMUM LENS THICKNESS OF .125 INCHES. 8. ALL SHEET STEEL USED IN FIXTURES ABOVE SHALL HAVE A PHOSPHATE LAYER APPLIED PRIOR TO PAINTING. VV1 P2-2 <E> 3 A ❑I REMOTE EXTERIOR F 0 EM. FIXTURE (TYPICAL) N <E> P2-2 B E <ERP> B - <ExE> ❑ I <E> -EXISTING WALL PACK FIXTURE FED FROM HOUSE PANEL (TYP.) HTING SYSTEMS PLAN EXISTING METER AND SERVICE DISCONNECT - <E> d AI I EXISTING I ❑ PANEL•P2to E SCALE 1/4" = I'-O`` 1K ROOM LIGHTING IS LY. OCCUPANCY ION WOULD ENDANGEF ' OF THE ROOM JRES, SWITCHES, BRAT JD MAINTAINED. <E> <E> B <E> P2;; ❑ ELECTRICAL KEY NOTES: ❑1 EXIT SIGNS AND EMERGENCY BATTERY UNITS TO BE CONNECTED TO THE LIGHTING BRANCH CIRCUIT IN THE AREA AHEAD OF THE LIGHTING CONTROLS. ❑2 REMOTE TWIN HEAD, LOW VOLTAGE, EMERGENCY FIXTURES POWERED VIA BATTERY UNIT ELECTRICAL DEMOLITION LEGEND SYMBOL DESCRIPTION <E> EXISTING TO REMAIN. <ER> EXISTING TO BE RELOCATED. <R> REMOVE AND TURN OVER TO OWNER. <ERP> EXISTING TO BE REPLACED. <ERC> EXISTING TO BE RECIRCUITED. <RE> RELOCATED, EXISTING EQUIPMENT SCHEDULE ��UM81,ER EQUIPMENT DESCRIPTION 1 PP It CREMATORY 2 BLP 500 CREMATORY SHELVING ING lT EEEEEEI MEDICAL WASTE 5 POCESS CHEST FREEZER 30" D X 55- W 7 S PECIAL IZATION AS PRI P LE INAI COOLER 0 S-8-P I CREMATORY ma Z 0 w 11111111 MENEENER Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a .o w� U Qo U w �- Lj O Q U U aw w w rZ LLJ U w am OD OU M U I Cr1 w J a �Q it PI-4 � W o � o � <E> a� z W C ; w w z mo 0 W w 0 THE Cra o I 0- P_ ENGINEER SEAL C 7- \ C EIVS •. GL i \�.0.• • No.61589,. ;• STATE OF j' 411 : <E> <E> Timothy C. Trewyn, PE P.E. No. 610 - _ TIESE DDIXWO, &M VM TIE COMTS Na OR BMW PRESENTED NEREM ARE MTM0 OLY FM THE SPEC6IC - WUR M MID CLW IF FW FORCE DOEf.RBlfi. INC. FM W H M WETS PREPAM REUSE M MPRO'TR RELW M DM DDI DOD VMW WRITTEN AUTIOMnffl AND ADAPTATM BY nRT PMU DOEMM, INC. SWILL DE VnMIT LTAD M m THE SANE CO'YRW020M rMT PIERCE E 04M MCu MC. ALL RMM RESERVED. BAY SHEET TITLE <E> <E> ❑ ...._ ELECTRICAL LIGHTING SYSTEMS <E> 2 PI-4 ❑ REMOTE EXTERIOR _ . <E> FLOOR PLAN EXI TIN EM. FIXTURE S G WALL PACK FIXTURE FED FROM (TYPICAL) HOUSE PANEL ISSUE DATE: (TYP.) 03-17-2021 DRAWN: TEC APPROVED: TCT DRAWING NUMBER E0 3 SHEET 3 OF 4 21001-03 RISER DIAGRAM GENERAL NOTES: INTERIOR EXTERIOR I INTERIOR I. E.C. SHALL MARK HIGH LEG ORANGE PER NEC 110.15. E.C. SHALL PROVIDE LABEL ON 400A FUSED DISCONNECT READING: "CAUTION C PHASE HAS 208 VOLTS TO GROUND" 2. E.C. SHALL PROVIDE ARC FLASH HAZARD WARNING SIGNS PER NEC 110.16. 3. E.C. SHALL LEGIBLY FIELD MARK PANELBOARDS WITH THE, DATE OF MARKING AND FAULT CURRENT AMPS (FCA) NOTED ON THE RISER DIAGRAM. 4. THE CONDUCTOR LENGTHS SHOWN ARE APPROXIMATE AND CONSERVATIVELY SHORT TO PROVIDE A MARGIN OF SAFETY IN THE CALCULATION OF FAULT CURRENTS. THE E.C. SHALL MAKE HIS OWN MEASUREMENTS AND ESTIMATE OF THE CONDUCTOR LENGTH REQUIRED. A I ELECTRICAL RISER DIAGRAM GRADE 6316 FICA EXIST. PANEL "P2" 200A sP M.L.O. _[JA3 EXISTING (3)#3/0, (1) #6G. IN 2" C EXIST. METER EXISTING 200A 2P CIRCUIT BREAKER EXIST. (I)#4 GRD. EXISTING (3)#3/01, IN2"C EXIST. METER EXISTING 200A 2P CIRCUIT BREAKER EXIST. (1)#4 GRD. EXISTING (3)#3/0 IN2"C Z EXIST.Ln w PANEL "P2" 200A P M.L.O. JA3 EXISTING BOND TO EXISTING BOND TO --i - L STRUCTURAL STEEL, STRUCTURAL STEEL, METALLIC WATER METALLIC WATER PIPE AND 20FT (_EXISTING PIPE AND 20FT EXISTING . CONCRETE -ENCASED - GROUND RODCONCRETE-ENCASED - GROUND ROD. ELECTRODE ELECTRODE — EXISTING (3)#3/0, (1) #6G. IN 2" C GRADE EXISTING FPL SERVICE FROM TRANSFORMER a 0 0 Z Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street SCALE _ (N.T.s.) Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a .0 wFr Qo U w U-- z a LU `� J w _ w F 0 0 w J 00� U CO LL. M z 0 F--I W J U O w W 0 J O z v LL z W � rr 0 Tr J U W 0 w U U W 0� M 0 a- A-� [i w ENGINEER SEAL NY C ` \�..•• G E NSA ••.ZL i No.6158�.� STATE OF *•4 00 SONA Timothy C. TrewYn. PE P.E. No. 61580 THESE M ENT , &M WITH THE WVEPTS W U2 DESMS PRESENTED lfltEIN ARE INTENDED ULY FM THE SPEWX ROM AND MW U FORT PIERCE ENGIHEEIM, INC. FOR WHICH THU VERE PREPARED. RETISE M DPROU RELIANCE M THESE DWJDTS WINUT VRI n AUTHOWTIIN MID ADAPTATMN DY FORT PMWE ENGREE M, INC. SHALL DE WITHOUT LIABILITY TN THE SALE CCPYRIIXT©E' M FWT PDma EN[iQEEM W_ ALL W.M RESERVED. SHEET TITLE ELECTRICAL RISERS, SCHEDULES AND DETAILS ISSUE DATE: 03-17-2021 DRAWN: TEC APPROVED: TCT DRAWING NUMBER E-4 SHEET 4 OF 4 21001-03