FORM R405-2017
FLORIDA, ENERGY EFFICIENCY CODE FOR, BUILDING CONSTRUCTION
Florida Department of Business -and Professional Regulation -Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACJj
Builder Name: WYNNE DEVELOPMENT
Street: ��3�q J�,,)� `C' �-�QS
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types.(1432.0 'sgft.).
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. - Number of Bedrooms 3
d. N/A
R= ftZ
5. Is this a worst case? Yes
10.. Ceiling Types (1783.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ftZ
6. Conditioned floor area above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ftZ) 0
c.
R= ft211.
Ducts
R' ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U=Factor: Sgl, U=1.04 111.36 ft2
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A f12
SHGC:
13. Heating systems
kBtu/hr .Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC: .
Area Weighted Average: Overhang Depth: 2:850 ft.
Area Weighted Average SHGC:. 0:285
14. Hot.wa.ter systems
8. Floor Types (1753.0 sqft.) Insulation Area
a Electric
Cap:.40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
g
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. NIA R= ftZ
15. Credits
Pstat
Total Proposed Modified Loads: 52.20
Glass/Floor Area: 0.086
PASS
Total Baseline Loads: 53.92
I hereby certify that the plans and specifications covered by
Review of the plans and
"'•.fit-��j
this calculation are in compliance with the Florida Energy
specifications covered by this
1r -
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
herebycertify that this buildin as desi ned, is in m liance
fY 9. 9 p
Florida Statutes.
� . . .
with the Florida Energy Code.
OWNER/A N�:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 114011111.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope -leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition. (2017) Compliant Software Page 1 of 6
1ORP,II R405-2017 INPUT. SUMMARY. CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User Conditioned Area: 1753
Lot #
Owner Name: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0
Street:
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:.
St. Lucie
Jurisdiction: Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name Area Volume
1 Entire.House 1753 14024
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO 224 1792 No 0
1
1
Yes
Yes
Yes
2 WIC 63 504 No 0
1
No.
Yes
Yes
3 MASTER BATH 56 448 No 0
1
Yes
Yes
Yes
4 M:BATH 61 488 No 0
1
Yes
Yes
Yes
5 LAUDRY 36 288 No 0 ,
1
No
Yes
Yes
6 . BEDROOM 2 1 180 1440 No 0
1
1
Yes
Yes.
Yes.
7 DINING/GREAT R 588 4704 No 2 .
1
Yes
Yes
Yes
8 KITCHEN 209 1672 Yes 0
1
Yes
Yes
Yes
9 BATH 50 400 No 0
1
Yes
Yes
Yes
10 HALL 25 200 No 0
1
No
Yes
Yes
11 FOYER 92 736 No 0
1
Yes
Yes
Yes
12 BEDROOM 3 169 1352 No 0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0
224 ftZ
____
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ftZ
____
0 1
0
3 Slab -On -Grade Edge. Insulatio MASTER BATH 8 ft 0
56 ft2
0 1.
0
4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0
61 ftZ
0 1
0
5 Slab -On -Grade Edge Insulatio LAUDRY. 1 ft 0
36 ft'
_—_
0 1
0
1/8/2020 4:43 PM . EnergyGauge®-USA 6.0.02. (Rev.-1) - FlaRes2017. FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT. SUMMARY. CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft2
0 1
0.
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 'ft
0
209.ft2
_e_
0 1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2.
0 1
0
10SIab-On-Grade. Edge Insulatio
HALL . 1 ft
0
25 ft2
---_
0 1
0
11SIab-On-Grade Edge. Insulatio
FOYER 9 ft
0
92 ft2
__e
0 1.
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
____
0 1
0
ROOF,
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt'Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1847 ft2
0 ft2
Light
. N
0.4
No 0:9
No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
MASTER BEDRO .
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56.ft2
0:1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
.36.ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 f12
0.1 ,
Wood'
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25.ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 . Knee Wall (Vented)
DINING/GREAT
19
Blown
30'ft2
0.11
Wood
WALLS
Adjacent
Space Cavity Width
-
Height
Sheathing' Framing . Solar Below
o .
1
E Exterior Concrete Block-
Int Insfi1ASTER BE 4.1 16
0 8
0
128.0.ft2
0 0
0.3
0
2
W Exterior Concrete Block-
Int InsbJASTER.BE 4.1 7
0 8
0
56.0 ft2
0 0
0.3
0
_ 3
S Exterior Concrete Block-
Int Ins88ASTER BE 4.1 14
0 8
0
112.0 ft2
0 0
0.3
0
1/8/2020 4:43 PM . EnergyGauge® USA 6.0.02.'(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of. 6
1ORM R405-2017 INPUT. SUMMARY°CHECKLIST:REPORT.
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar Below
it
Ornt
Tn
Wall Typi,Space
4
E
Exterior
Concrete Block - Int InSd1ASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_ 5
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
_ 6
E
Exterior.
Concrete Block - Int InsEREDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
- 7
S
Exterior
Concrete Block- Int InsQINING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
_ 8
W
Exterior
Concrete Block - Int InsliIINING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.3
0
9
W
Exterior
Concrete Block - Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
_ 10
E
Exterior
Concrete Block - Int Insul BATH .
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
11
N
Exterior
Concrete Block- Int Insul .FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
12
N
Exterior
Concrete Block - Int Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_13
W
. Exterior.
Concrete Block.- Int Ins8EDROOM 3
4.1 13.
0
6 0.
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block - Int InsI3EDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_ 15
N
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft' In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation _> changed to Worst Case.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth.
Separation
Int Shade
Screening
1
S 3
Metal Low E Single Yes
1.04 0.29
N
32.4.ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior 5
2
E 5
Metal Low-E Single Yes
1.04 0.29
N
6.9.ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-E Single Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low E Single Yes
1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Whotehouse Proposed ACH( 50) .000254 1168.7 64.16
120.66
.0881
5
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02. (Rev. 1)-flaRes2017 FBC 6th Edition (2017) Compliant Software Page 4, of 6
i=ORM R405-2017 . INPUT. SUMMARY,:CHECKUST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtu/hr cfm 0.85
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ -- Supply —
--- Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 175 ft2
Attic
55 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating Jan Feb
Mar
Mar
Apr
f Apr I
May X Jun Jul
May f Jun Jul
Au
AuSep
Se
Oct
E Oct
Nov
H Nov
Dec
Dec
Ventin Jan Feb
Mar
A r
May [ Jun Jul
Aug
Se
[X Oct
X Nov
Dec
Thermostat Schedule: 'HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9 10
11
12
Cooling (WD) AM.
78
78 78
78 78 78
78
78
80 80
80
80
PM
80
80 78
78 78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78 78
78
78
PM
78 -
78 78
78 78 78
78
78
78 78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68 68
68
68
PM
68
68 68
68 68 68
68-
68
68 68
66
66
Heating (WEH) AM
66
66 66
66 .66 68
68
68
68 68
68
68
PM
68
68 68
68 68 68
.
68
68,
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(I3 Ibs/sq.ft:
ft2
ft
0.3
WIC
Def6ult(8 Ibs%sq.ft.
ft2
ft
0.3
M. BATH '
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq:ft,
ft2
ft
0.3
BEDROOM 2.
Default(8 lbs/sq.ft.
ft2
ft
0.3 .
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02, (Rev. 1) - MR\ es2017 FBC'6th Editiori (2017) Compliant Software Page 5 of 6.
FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. ft2 ft 0'.3 GREAT/DINING
1/8/2020 4:43 PM EnergyGauge®•USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER.AND.INSULATION INSPECTION COMPONENT CRITERIA
TABLE.402.4.1.1
AIR BARRIER AND INSULATION INSPECTION'COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
U
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope:
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier..
not tie used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be.
shall be insulated by completely filling the cavity
sealed.
Wth'a material having a.thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and. framing,_ and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier..
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted -to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor.framing and extends from the
bottom. to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in linvented crawl spaces shall be covered with
. Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
'Air sealing shall be provided between the garage and:conditioned'spqc
m3z.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and. plumbing in exterior walls, or insulation that on
installation readily conforms to available space'shall
pytmd,hphind piping and wiring.
Shower/tub ,
The air barrier installed at exterior walls:adjacent to showers and
Exterior walls adjacent'to showers and tubs shall
on exterior wall
tubs shall separate -them from the showers.and tubs.
be insulated.'
Electrical/phone box or
The air barrier -shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the subAoor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended. by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
b en,firePoOkler cover plates and Molls or.cefflngs,
a. in auumon, inspection w iog.wans.snan be in accordance with the provisions -of 1GG-4uu.
1/8/2020 4:43 PM EnergyGauge@) USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE., LEVEL (EPL) VSPLAY:CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index,
the more efficient the home:
1. New home or, addition
1. New:(From Plans)
12. Ducts; location & insulation level
a) Supply ducts R
6.0
2. Single-family.or multiple -family
.2. Single-family
b) Return :ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4: Number of bedrooms
4. 3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0-
5. Is this a worst case? (yes/no)
5. Yes
b) Single package : SEER
c) Ground/water source SEER/COP .
6. Conditioned floor area (sq. ft.)
6. 1753
d) Room unit/PTAC EER .
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 1.058
b) Solar Heat Gain Coefficient (SHGC)
7b. '0.285
14. Heating system: Capacity
34.8
c) Area
7c. 151.4
a) Split_ system heat pump HSPF
8.5
b) Single package heatpump HSPF
8. Skylights
c)'Electric resistance • COP
a) U-factor:(weighted average)
8a. NA
d)-Gas furnace, natural gas , AFUE .
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace,. LPG AFUE
f) Other
9: Floor type, insulation level:
A) Slab -on -grade (R-value)
b)Wood,:raised (R-value)
c) Concrete, raised (R-value)
10-Wall type and insulation:
A: Exterior:
1. Wood frame. (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b): Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed.
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
10B1. 11.0
10132.
11a. 30.0
11 b.
11c. 19.0
11 d. No
15. Water heating system
a) Electric', resistance EF 0.97
b) Gas fired, natural gas EF
c). Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat:pump with tank EF
f) Heat recovery unit HeatRec%o
g) Other
16..HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
0-Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code', Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy.
saving features which will be installed (or exceeded). in this home before final inspection. Otherwise, a new. EPL
display card will, be completed based on installed code compliant features.
Builder Signature: ' Date:
��3�J
Address. of.New. Homer 5 , ` City/FL Zip:: FT. PIERCE, FL
1/8/2020 4:43:52 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page I. of 1