Loading...
HomeMy WebLinkAboutEnergy Efficiency Codei► r r FORM R405-2017 FLORIDA, ENERGY EFFICIENCY CODE FOR, BUILDING CONSTRUCTION Florida Department of Business -and Professional Regulation -Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACJj Builder Name: WYNNE DEVELOPMENT Street: ��3�q J�,,)� `C' �-�QS Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types.(1432.0 'sgft.). Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. - Number of Bedrooms 3 d. N/A R= ftZ 5. Is this a worst case? Yes 10.. Ceiling Types (1783.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ftZ 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ftZ) 0 c. R= ft211. Ducts R' ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U=Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A f12 SHGC: 13. Heating systems kBtu/hr .Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: . Area Weighted Average: Overhang Depth: 2:850 ft. Area Weighted Average SHGC:. 0:285 14. Hot.wa.ter systems 8. Floor Types (1753.0 sqft.) Insulation Area a Electric Cap:.40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 g b. Conservation features EF: 0.970 b. N/A R= ft2 None c. NIA R= ftZ 15. Credits Pstat Total Proposed Modified Loads: 52.20 Glass/Floor Area: 0.086 PASS Total Baseline Loads: 53.92 I hereby certify that the plans and specifications covered by Review of the plans and "'•.fit-��j this calculation are in compliance with the Florida Energy specifications covered by this 1r - Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 1-9-20 this building will be inspected for compliance with Section 553.908 herebycertify that this buildin as desi ned, is in m liance fY 9. 9 p Florida Statutes. � . . . with the Florida Energy Code. OWNER/A N�: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 114011111. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope -leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition. (2017) Compliant Software Page 1 of 6 1ORP,II R405-2017 INPUT. SUMMARY. CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County:. St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire.House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No. Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M:BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 , 1 No Yes Yes 6 . BEDROOM 2 1 180 1440 No 0 1 1 Yes Yes. Yes. 7 DINING/GREAT R 588 4704 No 2 . 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ftZ ____ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ftZ ____ 0 1 0 3 Slab -On -Grade Edge. Insulatio MASTER BATH 8 ft 0 56 ft2 0 1. 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ftZ 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY. 1 ft 0 36 ft' _—_ 0 1 0 1/8/2020 4:43 PM . EnergyGauge®-USA 6.0.02. (Rev.-1) - FlaRes2017. FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT. SUMMARY. CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0. 8 Slab -On -Grade Edge Insulatio KITCHEN 11 'ft 0 209.ft2 _e_ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2. 0 1 0 10SIab-On-Grade. Edge Insulatio HALL . 1 ft 0 25 ft2 ---_ 0 1 0 11SIab-On-Grade Edge. Insulatio FOYER 9 ft 0 92 ft2 __e 0 1. 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ____ 0 1 0 ROOF, / Roof Gable Roof Rad Solar SA Emitt Emitt'Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light . N 0.4 No 0:9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO . 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56.ft2 0:1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown .36.ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 f12 0.1 , Wood' 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25.ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 . Knee Wall (Vented) DINING/GREAT 19 Blown 30'ft2 0.11 Wood WALLS Adjacent Space Cavity Width - Height Sheathing' Framing . Solar Below o . 1 E Exterior Concrete Block- Int Insfi1ASTER BE 4.1 16 0 8 0 128.0.ft2 0 0 0.3 0 2 W Exterior Concrete Block- Int InsbJASTER.BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 _ 3 S Exterior Concrete Block- Int Ins88ASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/8/2020 4:43 PM . EnergyGauge® USA 6.0.02.'(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of. 6 1ORM R405-2017 INPUT. SUMMARY°CHECKLIST:REPORT. WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it Ornt Tn Wall Typi,Space 4 E Exterior Concrete Block - Int InSd1ASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _ 5 E Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 _ 6 E Exterior. Concrete Block - Int InsEREDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 - 7 S Exterior Concrete Block- Int InsQINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 _ 8 W Exterior Concrete Block - Int InsliIINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 9 W Exterior Concrete Block - Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 _ 10 E Exterior Concrete Block - Int Insul BATH . 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 11 N Exterior Concrete Block- Int Insul .FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 N Exterior Concrete Block - Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _13 W . Exterior. Concrete Block.- Int Ins8EDROOM 3 4.1 13. 0 6 0. 104.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block - Int InsI3EDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _ 15 N Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft' In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation _> changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth. Separation Int Shade Screening 1 S 3 Metal Low E Single Yes 1.04 0.29 N 32.4.ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 E 5 Metal Low-E Single Yes 1.04 0.29 N 6.9.ft2 1 ft 0 in 1 ft 5 in None None 3 E 6 Metal Low E Single Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in None None 4 S 7 Metal Low-E Single Yes 1.04 0.29 N 39.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W 8 Metal Low E Single Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in None None 6 W 13 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whotehouse Proposed ACH( 50) .000254 1168.7 64.16 120.66 .0881 5 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02. (Rev. 1)-flaRes2017 FBC 6th Edition (2017) Compliant Software Page 4, of 6 i=ORM R405-2017 . INPUT. SUMMARY,:CHECKUST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / -- Supply — --- Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Heating Jan Feb Mar Mar Apr f Apr I May X Jun Jul May f Jun Jul Au AuSep Se Oct E Oct Nov H Nov Dec Dec Ventin Jan Feb Mar A r May [ Jun Jul Aug Se [X Oct X Nov Dec Thermostat Schedule: 'HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM. 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 - 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68- 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 .66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 . 68 68, 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(I3 Ibs/sq.ft: ft2 ft 0.3 WIC Def6ult(8 Ibs%sq.ft. ft2 ft 0.3 M. BATH ' Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq:ft, ft2 ft 0.3 BEDROOM 2. Default(8 lbs/sq.ft. ft2 ft 0.3 . ENTRY Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02, (Rev. 1) - MR\ es2017 FBC'6th Editiori (2017) Compliant Software Page 5 of 6. FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. ft2 ft 0'.3 GREAT/DINING 1/8/2020 4:43 PM EnergyGauge®•USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER.AND.INSULATION INSPECTION COMPONENT CRITERIA TABLE.402.4.1.1 AIR BARRIER AND INSULATION INSPECTION'COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: U Owner: Jurisdiction: w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope: Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier.. not tie used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be. shall be insulated by completely filling the cavity sealed. Wth'a material having a.thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and. framing,_ and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier.. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted -to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor.framing and extends from the bottom. to the top of all perimeter floor framing members. Crawl space walls Exposed earth in linvented crawl spaces shall be covered with . Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned s ace shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation 'Air sealing shall be provided between the garage and:conditioned'spqc m3z. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and. plumbing in exterior walls, or insulation that on installation readily conforms to available space'shall pytmd,hphind piping and wiring. Shower/tub , The air barrier installed at exterior walls:adjacent to showers and Exterior walls adjacent'to showers and tubs shall on exterior wall tubs shall separate -them from the showers.and tubs. be insulated.' Electrical/phone box or The air barrier -shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the subAoor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended. by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids b en,firePoOkler cover plates and Molls or.cefflngs, a. in auumon, inspection w iog.wans.snan be in accordance with the provisions -of 1GG-4uu. 1/8/2020 4:43 PM EnergyGauge@) USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE., LEVEL (EPL) VSPLAY:CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home: 1. New home or, addition 1. New:(From Plans) 12. Ducts; location & insulation level a) Supply ducts R 6.0 2. Single-family.or multiple -family .2. Single-family b) Return :ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4: Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0- 5. Is this a worst case? (yes/no) 5. Yes b) Single package : SEER c) Ground/water source SEER/COP . 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER . e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. '0.285 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split_ system heat pump HSPF 8.5 b) Single package heatpump HSPF 8. Skylights c)'Electric resistance • COP a) U-factor:(weighted average) 8a. NA d)-Gas furnace, natural gas , AFUE . b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace,. LPG AFUE f) Other 9: Floor type, insulation level: A) Slab -on -grade (R-value) b)Wood,:raised (R-value) c) Concrete, raised (R-value) 10-Wall type and insulation: A: Exterior: 1. Wood frame. (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (insulation R-value) 11. Ceiling type and insulation level a) Under attic b): Single assembly c) Knee walls/skylight walls d) Radiant barrier installed. 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 10B1. 11.0 10132. 11a. 30.0 11 b. 11c. 19.0 11 d. No 15. Water heating system a) Electric', resistance EF 0.97 b) Gas fired, natural gas EF c). Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat:pump with tank EF f) Heat recovery unit HeatRec%o g) Other 16..HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No 0-Whole house fan No d) Multizone cooling credit e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code', Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy. saving features which will be installed (or exceeded). in this home before final inspection. Otherwise, a new. EPL display card will, be completed based on installed code compliant features. Builder Signature: ' Date: ��3�J Address. of.New. Homer 5 , ` City/FL Zip:: FT. PIERCE, FL 1/8/2020 4:43:52 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page I. of 1