HomeMy WebLinkAboutProject Informationr + lrft, Project Summary : � a Entire House By. -QUICK CALCS, INC. - 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM Project Information For:. WYNNE DEVELOPMENT THE WINDSOR IMPACT, FT. PIERCE, FL Notes: Design • • Weather: Fort Pierce, FL, US Winter Design.Conditions r Summer Design Conditions Outside db 42 OF Outside db . 90 OF Inside db. 70_ . OF Inside.db 75 OF Design7b 28 OF Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment.Load Sizing Structure 20795 Btuh Structure 16420 Btuh Ducts 6191 Btuh Ducts 9337 Btuh Central vent (0 cfm) 0 Btuh Central. vent (0 cfm) 0 Btuh none none) Humidifidation- 0 Btuh Blower 0 Btuh Piping: 0 Btuh Equipment load 26986 Btuh Use manufacturer's data n Rate/swingg multipplier 0.95 Infiltration EquiprrientsenSi6leload 24470 Btuh Method Simplified Latent -Cooling Equipment.Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent (O dm) 0 Btuh Heatingg. Coolingg� . . (none) Area (ft� 1753 176% Equipment latent load 5041 Btuh Volume (fp). 16478 16478 Air changesmour 0.38 0.20 Equipment Total Load (Sen+Lat) 2951.1 Btuh Equiv. AVF (cfm) 104 55 Req. total capacity at 0,70 SHR 2.9 ton Heating -Equipment Summary Cooling. Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade' CARRIERAIR CONDITIONING Model 25HBC5369030: Cond 25HBC536A O30 AHRI-ref 7914585 Coil FX4DN(B:F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER .Heating input Sensible-000ling 24360 Btuh Heating output 34600. Btuh @47°F Latent000ling 10440 Btuh Temperature rise 27. °F Total cooling . 34800. Btuh Actual airflow 1160 cfm Actual airflow 1160. cfm Airfiowfactor 0.043 cfniBtuh Airflowfactor. 0.045 ofrrlBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=.36 °F Backup: Input= 7 kW Output = 23009 Btuh,100 AFUE Calculations approved,byACCAto meet all requirements of Manual J 8th Ed. 2020-Jan-081622:01 .m wryn. �meaauawrs= ww Right SLite@ LJdversal 20l9l9.0.07 RSU08101 Page 1 tslWdghlsoftWAC\WYNNE-THEWINDSOR-IMPACTryp Calc=MJ8 FrortDoorfaces: N �� Ri ht-M Worksh .eat °b 9 Date: Entire House QUICK CALLS, INC. By . s� r a i. r.uue Irv., r �.,ritrcco, ru �gygo r<rrone: i.c�-•roo-oroa rax. i iz-�rocaoroo cman: uuwncr�w�w/�u�.yum 1 Room name Enlire House BEDROOM 2 EVosedvdl. 180.6 ft 41.0. ft 3 .Room height. 9.4 ft d 9A It heaUaool. 4 5 Room dimensions . Room area 1753.0 ft' 14.0. x 20.0 ft 280.0 tf Ty . Construction U-value„ Or HTM Area Load Area (ft� Load number (BtuhliF-*F) . (BMW or perimeter (tt) (Btuh) or perimeter (8) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S. Heat Cool 6 11 VI�I--G W W' W. 13A flocs IA-dlom: 13AAom 13A-0ocs; 1Aclom 11D¢ ' 13AAocs 0.143:- 1270 0143 0143 1270 0390 0.143 n `fi n. ne a `e ;e se 4.60. 35.56 4.00 4:oo 35.56 9092 4.00 2 55 34:77 2.55 2:55 67,06 11:31 2.55 649 15 27 141 20 . _ _ _ 21 27 596 0 27 100 1 1---" .`. 21. 27 2386 533 106 400 711 .... , 229 106 1517 522 68 255 1741 ,.. 238 68 66 0 0 0 0 ;:_, ._ `0 0 ' 66 0 0 0 ' 0 _ 0 0 263 0 0 0 0 1 0 0 167 0. 0 0, Q 0: 0 Vy _ �G W 13AAocs ,1Aclom 13A-4ocs 1Ao1om 0143 1270 .0.143 1270 ;-s _ s w w 4-00 35;56 4.00 35.56 2:55 , , 34:77., 2.55 54.53 536 .,:.6 320 12 530 : . -. ...6. 255 1 2121 ,_ . 213...: 1022 415 1349 ., ,209 649 636 i88 s: :0' 132 12 ,z 188 °0 108 1 753 432 415 479. 275 636 1A-dom ,1270 w 35.56 54.53 12 1 427 654 12 1 427 654 P 4A5-2om 12C-0sw.: 0770 0.091 w - - . 21.56 ..... 255 45.63 . 128 41 „ _. ° 254 2 . , ,_,. g 254 880 :. 647 1862 326 0 : `. . 0 0 _ .. r: 0 0 ;' 0, 0 ,. - 0: C F 1.6A-30md ?A1: '.. 0.032 0.989 , - :; - 6.90 J.. 27.69 2.32 ;0:0011 1753 1753 1571 . , 4067 0 280 280 251 .. 650 A. 61 0) AED excursion 3971 488 Envelopeloss(gain 17583 .15285 3676 3349 12 a) Infiltration 3211 965 729 205 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Appliances/other 0 0 Submtal(lines 6to13) 1 20795 164201 4405 3554 Less wtmal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20795 16420 4405 3554 15 Ductloads 30% 57% 6191 9337 30% 57% 1312 2021 Total room load 26986 25757 5717 5575 Air required (clm) 1 1 11601 1160 ' 246 251 Calculations approved WACCAto meet all reauirements of Manual J 8th Ed. RigtESute®Uriversa1201919.0.07 RS W 2020-Jan-081622:01 6101 Page 1 -tslWrightsoftWAC1WYNNE-THEWINDSOR-IMPACTnp Calc=MJ8 FrortDoorfaces: N t -9 - w Right-JO Worksheet �°b Entire House. By- ey: QUICK CALLS, INC. 317 ST. LUGE LN., FT. PIERCE', FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 0 ft 9.0. ft 3 ,EJqosedvrall. Room height 9.4 It heaUceol 9.4 ft heaftol 4 5 Room dimensions Room area 7.0 x 9.0 It 63.0 ft2 7.0 x 9.0 ft 63.0 ftz Ty . Construction U-value, Or HTM Area (ft-) Load Area (its Load number (BtuWF) (BtuhAtl or perimeter (iq (Btuh) or perimeter(ft) (Btuh) Heat Cod Gross N/P/S • Heat Cool Gross N/P/S Heat Cool 6 11 VI�I--G 13A-4ocs 1A-clom 4A52om 13A�400S . 13A46cs 1Ac1om:. ,11D0 13A4ocs 13A46 s " : .1Ac1ort1'' _ 0143 1270 „-0770 0143 0143 1270 0390, 0.143 0143 1270 n n n: rle a a se s .: S 4:00 35.56 21:56 4.00 4:06 M56 4.00 4:00 :35:56 2 55 3477 2.55 2j55 870. 2.55 2:55 347 ` 0 0 0 0 0 0 , .. 0 0, 0 0 0 0 0 , , 0 0 0 0 0 0 0 , 0 s 0 0 0 0 0 0 0 :° 0: 0. 0 `0 0 85 -e U 0 0 0 0 , 0 0 85 , .. 0 0 0. 0 01 0 0 339 ".. a0 Q 0 A Q Q 0 '21 S ' G W .,. W W �j ... r 13A4ocs 1A-c1om 1A-clom 0.143 1270 1270 w w w 4.00 35.56 35.56 2.55 54.53 54.53 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P . C F 4A5-2om 12C-0sN, ` 16A-30md 22A-O:' 0.770 0 091 0032 0 989 w :. _, - _ .._ 21.56 265 6.90 .27.69 45.63 , _ 128 2.32 .. .. O:OU 0 ` -':' 0 63 . 6$ 0 ' 63 0 0 56 .. _ .-A 0 ;;, 0 146 0 .: O 63 0 :x , U 63 9 0 : 0 56 <249 0 "• 0 146 i - 6 c) AED excursion . -10 -28 Envelopeloss/gain 56 136 1 1 644 I334 12 a) Infiltration 0 0 160 45 b) Robmveritilaton 0 0 0 0 13 Internal gains: Oaupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines6to13) 56 136 804 379 Lessextemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 56 136 804 379 15 Ductloads 30% 57% 17 77 30% 57% 239 216 Total room load 73 214 1044 695 Air required (cfm) 3 10 45 27 Calculations approved WACCAto meet all requirements of Manual J 8th Ed. L - Right-Siite®lhiiversal201919.0.07 RSW8101 2020-Jan-081622:01 .-tsxwdghtsoftWAMWYNNE-THEWINDSOR-IMPACTrip Calc=MJ8 FrordDoorMoss: N Page AJL J V rat aft Right-JO Worksheet ob: Entire HiDuse Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr..PIERCE, FL 34946 Phone: 772466-6799 Fax772466-6796 Email: QUICKC.ALCS@ADL.COM 1 Room name PA BATH WCHEN 2 Exposedwal[ 8.0, It 0 It 3 Room height 9.4 It heat/cool 9.4 ft heatfcool. 4 5 Room dimensions Room area . 7.0 x 8.0 It 56.0 fe 1.0 x 1720 it 172.0 ftZ Ty Construction U-value Or HTIVI Area (ft Load Area Load number (BtuWF) (BWhffl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat C6.1 G. N/P/S Heat Cool 6 '13A-4406S oM 4A5.2om • 0 143 ... 0.770 n -�A'06 3556 2, 5 -Xn ,'o 0 0 0 0, -0 i.0 JZ 0 j. 0 11 w lvj�� w 13A-4ocs 13A,� 1Xclorn 11D0::': 13A4ocs 0.143 -6.143 1270 0.390 0.143 ne �41 e�j- ' ; -se 4.00 4.66 '35 66 _ ' 10.92 4.00 2.55 �.'266 �'-87-06 ft.31 2.55 0 -0 0 • 0 :W, %0 0 0 6 �: 0 0 0 0 -0 - 0 0 ..z 1. 20 0 0 0 0 0 .0 0 V,V'13A-flocs ,G, 11Xiorri � 13A4ccs 1A--1om A.143 U70 0.143 1270 -'-s' s w w 4.09 .26. 56 4.00 35.56 2.56 -34.77 2.65 64.53 75::-, 0 0 -69 -''--" 6 0 . 0 -2 77 -210 3 0 -,-.2W , 0 0 . 0 0 0 0 0 ­0 0 . 0 J �A Q. 0 lAr-dom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 P C F - 4A5-tom 2C-0sx 16A-30md 22A4pI-..- 0.770 -0.091 0.032 0.986 w 21.56, 2.55 0.96 27.69 45.63 2.32 0 56 0 56 -0 50 0 130 0 172 0 76 172 0 154 0 =96 399 -4 Z:. A- 2 6 q) AED excursion -38 -34 Envelope loss(gain 762 477 346 462 12 a) Infiltration 142 40 0 0 b) Roomventilafion .0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianoearother 0 0 Subtotal (lines 6 to 1.3) 904 517 346 462 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 904 517 346 462 15 Ductloads 30% 57% 269 294 30% 57% 103 263 Total room load 1 1174 811 1 449 725 Adr required (c1m) .50 371 19 33 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2020-Jan-08 1622:01 Rght-suteouniversall 201919.0.07 RSU08101 Page 3 ts\WdgftsoftWAC\VVYNNE-THEW.INDSOR-IMPACT.rLp Calc=MJB Front Door faoes:N Right-J@ Worksheet Job: rF Date: Entire House By. QUICK CAMS, INC. 317 ST. LUCIE LM, Fr. PIERCE, FL 34946 Phone: 7724M6799 Fax 772466-6796 Email: QUICKC,ALGS@koL.COM I Room name BATH BEDROOM2 2 ExposedvWl 5.6 ft 42.6 it 3 Room height 9A ft heat1bool 9A ft heatbcol 4. 5 Room dimensions Room area 9.0 x 6.0 It 45.0 T 1.0 x 204.0 It 204.0 T Ty Constudon, number U-Value (BtuhAf-T) Or HTM Area (ft 2) or -perimeter @ Load (Btuh) Area or pefimeW M Load (Bluh) Heat cod Gross N. PIS Heat Co'ol Gross W/S Heat. Cool 6 I'MAbcd- 00141 '.1170 I 770 0. - n'. ' -'n- .410 3 35 56 . 34177 , 0 'k "527 -"� o 335 w 11 '13A-46m i 3A4oca . 0.143 O.W ne "..,e, 4.00 _4.00- 2.5.5 0 0 0 -"-'b 0 77 -86 27 106 -'259 68 LAD- fV0 '4--� 35.' 20 .1 'm -174:1 -110T -JO.92": 11'.3 T� .. - � , 7. � " -:: 0 . . .. .:. �'%: I ,. " - -*"'�' . , - i 0 w 13A-4ocs 0.143 se 4.001 2.65 0 0 0 0 V 27 106 -68 : 13A4ocs -0.14`3,..s 4.01j.',--, -� 6- � ..;_ - .- �'- , "0: 13A4om 1 vo 0.143 w 56 35.5 4.00 -V 2.55 6 0 0 0 0 0 -'0 0 A 0 0 -G IA-clom lArdom 1.270 1. 2'01 w W 35.56 35.56 56 54.53 54.53 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 ' A5-tom "1204sw 0.770 ,21:56 256 45.0 -1 A '0 '�"o "'o 0 0 0' 0 IS+ 0 -"''o P C 16A-30md 0.0321 0.96 2.32 45 45 204 204 183 473 F 22A-to"-,• 0.999 27.69 0.66'... -40 174 N Envelope loss(gain 367 207 3599 3085 112 a) Infiltration 89 25 758 21 1 4 b) Room ventilation 0 0 0 0 3 Intamd gains: Occupants,@ 230 0 0 0 0 Applianoerdother 0 0 Sublotal(lines6to13) 456 232 4357 3299 Lesse)"em "load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 456 232 4357 3299 15 Ductloads 30% 00 136 132 300/0 57% 1297 18761 Total room load 692 364 1 5654 6174 Air required (dm) 25 16 .2431 2331 Calculations approved byACCAto meetall requirements of Manual J.8th Ed. vvsvttr 2020-Jan-08 1822:01 A& Right-SLite@Uiversal2Ol9l9.0.07RSUOSIOI Page 4 ...tskwdgftsoftWAQWYNNE-THEWINDSOR-IMPACT.rLip Calc=MJB Front Door faces: N 1 -F olvavghl fr° Right-J® Worksheet Job: Entire House Date` QUICK CALCS, INC. By 317 ST. LUCIE LN., FT.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 .Email QUICKCALCS@f10L.COM 1 Room name ENTRY LAUNDRY 2 Exposedv`all 6.0 ft 6.0 It 3 Room height 9A ft heaV000l 9.4 ft heafl000l 4. Room dimensions 1.0 x 92.0 ti 7.0 x 6.0 ft 5 Room area 92.0 1P 42.0 If Ty Construction U-value Or . HTM Area (ft2) Load Area Load number: (Btuhlft;°F) or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross NOS Heat Cool 6 13A flocs. 0143 n: 4.00 255 0 0 - 0 0 '_ 0 0 0 0. 1Ac1om,: 1270 n; 35.56 3477 - 0 0 0 0 0 0 0 0 4A5-tom 0770. n.. ,21.56 1931 ::0 U Q 0 ;. O:F `0 0.- :0. W 13A40c; 0.143 ne 4.00 2.55 0 0 0 0 0 0 11 W �-G cs 13A-4o. -'0143 e' 4:00 2.55 , S6 . 35 . 142 90 _. 0 0 -0 0 IXdom. 1270 e.- 3556 8T06 0 0 0 0 0'', 0 0 0 �D 11D0 .' 0390 .e!. 10.92 1131 t 21. ... :'. 21 , . ;: ' 229 238 :; _ 0 W 13A4ocs 0.143 se 4.00 _ 2.55 _ 0 0 0 0 0 0 0 0 13A 4ors 0143 _ s 4`.00 25$ 0 0 0 0 56 -; 56 226 144 G 1Ac1om ... .. 1270, s 3566. .%,.77 ,.-. 0 0 0 .- 0:- .. 0 { W. 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G 1A-c1om 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5.2om 0770 w 21.56 45.63 0 0 0 0 0 0 0 0 P . 12C 0 N°. 0091 '° ? : 255 1'28 173 ":�113 ...,;. 287 .... 145 .= , -,.66 : � . 66 168 C 16A-30md 0.032 - 0.96 232 92 92 82 213 42 42 38 97 F 22A-1p1• . 0.989 - 2769 . .--.0:00 . 92 .., : g .: :...166 > .... 0 :: _ :. . 42: 6 l: 166 . p 6 c) AED excursion .49 -24 Envelopeloss(gain 907 637 597 301 12 a) Infiltration 107 30 107 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 1014 667 704 331 Less extemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistributon 0 0 0 0 14 SubtDW 1014 667 704 331 15 Ductoads 30% 57% 302 379 30% 57% 210 188 Total room load T1316 1047 1 914 520 Air required (dm) 57 47 39 23 Calculations approved WACCAto meet all requirements of Manual J 8th Ed. RightSuteGuriversal20l9l9.0.07RSU08101 2020-Jan-081622:01 Aft,...ts\WrigtboftWAC\WYNNE-THEWINDSOR-IMPA&xtp Calc=MJ8 FrorrtDoorfaces: N Pages aJob: ht-®Worksheet Date: Entire House By: QUICK CALCS, INC. 317 ST. LUGE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name GREAT/DINING Room7 2 . EVosedvdi. 50.0 ft 13.0. It 3 Room height 9A It heat/000l . 9A ft heattool 4.. 5 Room dimensions Room area 1.0 x 567.0 It 567.0 T 13.0 x 13.0 ft 169.0 fe Ty Construction 1.14lue Or HTM Area Load number (Btuh/ft�°F (BtuhtF,) or perimeter (f0 (Btuh) orperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S. Heat . Cool 6 11 _ G W ". W' I�-G I=D, W V,V G 13A-0ois 1A ctom 4A5-2omz• 13A4ocs " 1344or ;, 1Ac1om 11D0 13A-4ocs 13A-4ocs .1Actom '. 13A-4ocs 0143 ;.1270 . "_,0T/0 0143 0143 1270 ,0390 0.143 ...r0143 1270 0.143 n n .,.n ne e' a e; se s; . S . w 400 3556 ,. 2156 4.00 400 3556 ,10.92, 4.00 4;00 .35:56 4.66 255 1931. 2.55 755 8706 - 11;31 2.55 2;55 34.77 2.55 282 . -�., x36 0 ' 0 0 0 : 0 . t) 188 244 _.__. - . Ca... 0 0 0 0 0 _ !.,_.0 147 978 0 � ,815.. 0 0 jF 0 0 0 . ` 0 589 622 0 .i ,.��.:;z 0 0 0 0 0 T 0 ._ "-`.... 0 375 122 _._. C 0 0 0' 0 .: .... 0 0 107 -0 : ..7 t _....0 0 - 0 0 ; 0 0 429 533 ;.:;p 0 0 0 0 27�3 5 , , .:.0; 0 0, p ' 0 0 1Ac1om 1270 w 35.56 54.53 0 .0 0 0 0 0 0 0 1A-dom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 P .: :'.12C-0sw.... C F _. 4A5-2om 16A-30md 22A-tpt,: `., ., 0770 0091 0032 _. 0989 w ,' _ - .:._ 21.56 255 0.96 i 2769 45.63 .. . ,1.28 2.32 .. 0:00 41 .. ';'`- 0 567 ,. .: ,:567 2 _ 0 567 „ -'ti 5U 880 p 508 .':..; 1385 1862 1315 .. x.... 0 0. 169 ;: ..169 0. 169 13 0 151 0 392 V. 6 c) AED excursion 307 -100 Fnvelopeloss(gain 5154 5210 1474 1086 12 a) Infiltration b) Room ventilation 889 0 251 0 231 0 65 0 13 Internal gains: Oocupants.@ 230 0 0 1 230 Appliances(other 0 0 Subtotal oines6 to 13) 6043 5461 1705 1381 Less extemal load 0 0 0 0 14 Lessbanskr Redistribution Subtotal, 0 0 6043 0 0 - 5461 0 0 1705 0 0 1381 15 Ductioads 30% 57% 1799. 3105 3Wo 1 57% 508 765 Total room load - 7843 8566 2213 2167 Air required (cim) 1 1337 386 95 98 Calculations approved bVACCAto meet all requirements of.Manual J 8th Ed. ii- war »,. 2020.Iarr081622:01 Rigk-Sute®Uriversal 201919.0.07 RSU0B101 .-tslWdgttsoftWAC1WYNNE-THEWINDSORIMPACT.rup Calc='MJB. FrordDoorfeoss: N Page6 Job: wrightsoft Duct System Summary ate. Entire House By. QUICK. CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS(J10L.COM P-roject intormation For. WYNNE DEVELOPMENT . THE WINDSOR IMPACT, FT. PIERCE, FL Heating Cooling Extemal.static pressure 0 in H2O: 0 in H2O Pressure losses ' 0 in H2O 0 in H2O Available static pressure 0' in H2O 0 in H2O Supply /,return available pressure 0.000 / 0.000 in H2O 0.000 / 0.000' in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual airflow 1160 cfm 1160 ch Total, effective length: (TEL)- 0 .ft I Supply Branch Detail Table Name Design. (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM c -2788 123, 126 0 0 OxO ShMt 0 0 BEDROOM 2 h 2587 122 117 0 0 Ox 0 ShMt 0 0 BEDROOM 2-A h 2587 122 117 0 0 Ox 0 ShMt 0 0 BEDROOWA c 2788 123 126 0 0 Ox 0 ShMt 0 0 ENMY h 1047 57 47 0 0 Ox 0 ShMt .0 0 GREATIDINING c 2855 112 129 0 0 Ox 0 SFiMt 0 0 GREATIDINING-A c 2855 112 129 0 0 Ox 0 ShMt 0 0 GREATIDINING-B c 2855 112 129 0 0 Ox 0 ShMt 0 0 KITCHEN c 725 19 33 0 0 Ox 0. ShMt. 0 0 LAUNDRY h 520 39 23 0 0 Ox O ShMt 0 0 M, BATH h 811 50 37 0 0 Ox 0 ShMt 0 0 MASTERBATH h 595 45 27 0 0 Ox0 ShMt 0 0 Room? . c 2167 95 98 0 . 0 Ox 0 ShMt 0 0 WIC c 214 3 10 0 0 Ox 0 ShMt 0 0 Return Branch detail Table Name Grille Size (in) Htg (drn) Clg (cfm) TEL M Design FR veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat! Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 ShMt ofslri�i9�st7ffi® 2020-Jao-081622:02 �mrt+aie.mwanama.vs. ro Right-SLite®Uriversal 20l9l9.0.07 RSU08101 Page 1 ...ts\WrigttwftWAC1WYNNE-THEWINDSOR-IMPACTnp Calc=MJS FrontDoorfaces:N