Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
MiTek® RE: M11392 MiTek USA, Inc. THE WINDSOR 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: Wynne Dev Corp Project Name: M11392 Lot/Block:- Model: 71 Carlton 3 Bedroom Rear Porch Address: unknown Subdivision, City: St. Lucie County State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TPi2014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T16686490 a 4/3/2019 2 T16686491 a1 4/3/2019 3 T16686492 a2 4/3/2019 4 T16686493 a3 4/3/2019 FIL 5 T16686494 a4 4/3/2019 E COPY . 6 T16686495 a5 4/3/2019 7 T16686496 ata 4/3/2019 8 T16686497 b 4/3/2010 9 T16686498 bha 4/3/2019 10 T16686499 gra 4/3/2019 ��'���® F:OR 11 T16686500 j1 4/3/2019 �. wwAAPL��rYCFE 12 T16686501 j3 4/3/2019 F C;oM 13 T16686502 j5 4/3/2019 O®®C®utq-ry 14 T16686503 j7 4/3/2019 S-r. LUC1E 15 T16686504 kj7 4/3/2019 BOCCj The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Finn, Walter My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that -the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into.account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSIfrPI 1, Chapter 2. 1 of 1 EN SF•'Ai i :• No 22839 ��� STATE OF •:�� .�♦ Walter P. Finn PE No.22839 MiTek USA, Inc: FL Cert 6634 6904 Parke East Blvd: Tampa FL 33610 April 03, 2019 Finn, Walter Job Truss Truss Type Qty Ply THE WIND OR T16686490 M11392 A HIP 1 1 • Job Reference (optional) o.wus.uec o,zvio mllex Inaustrles, Inc. yvep Apr JIUn6:4J ZUIU rageI ID;_kfiGCA6bx7j2Syl HDXFw7ye3KX-j516o6uNUlw752lcX?ocWyM5YnfBOhBOwcl WRozUScg 1-0-0 6-10-14 9-0-0 . 14-11-0 20-2-13 26-0-0 28-1-2 35-0-0 6-0- -0-0 6-10-14 2-1-2 S-11-0 5-3-13 5-9-3 2-1-2 6-10-14 -0-0 Scale = 1:60.5 4x8 2x3 II . 3x6 = 4x4 = 4x8 = 4.00 12 2x3. 2x3 \\ 4 26 5. 6 7 27 8 9 m1 2 0 3x4 = 3 25 28 24 29 17. 16 15 14 13. 12 3x4 3x6 — 6x8 = 3x4 = 3x6 — 3x4 = 9-0-0 14-11-0 20-2-13 26-0-0 35-0-C 9-0-0 5-11-0 5-3-13 5-9-3 9-0-0 3x5 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.42 12-23 >572 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.47 Vert(CT) 0.37 12-23 >659 180 BCLL 0.0 Rep Stress Incr YES WB 0.94 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 161 lb FT = 206/6 LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-5-1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=433/0-8-0, 15=1596/0-8-0, 10=669/0-8-0 Max Horz 2=-97(LC 10) Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12) Max Grav 2=467(LC 17), 15=1596(LC 1), 10=685(LC 22) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-639/108, 3-4=-396/0, 4-5=-967/776, 5-7=-967/776, 7-8=-454/938, 8-9=-1009/1884, 9-10=-1265/2154 BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-1586/938, 10-12=-1971/1174 WEBS 3-17=-372/461, 4-17=-272/451, 4-15=-1087/1002, 5-15=-336/386, 7-14=-766/399, 8-14=-580/997, 8-12=-958/447, 9-12=-358/600, 7-15=-1329/2190 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE.7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Extedor(2) 9-0-0 to 13-11-6, Interior(l) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf.bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 Ito uplift at joint 2, 1439 lb uplift at joint 15 and 799 lb uplift at joint 10. WalterP, Finn PE'No.22838; MiTak USA,'Ine. FL Cert 6634 '6904 Parke East Blvd: Tampa FL" 33619 Date;; April 3,2019 s. -- r AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M ITe ICs is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686491 M11392 Al SPECIAL 1 1 Job Reference (optional) �numueis i russ, inc., rurr tierce, rL o.Z4U s uec o zuits MI teK Inausines, Inc. vvea Apr J IU:16:44 ZUIU rage 1 ID:_kfiGCA6bz7j2Syl HDXFw7ye3KX-BIsU?Su?F32JCKo5jKr39uFQBuX19198Gn4_EZUSCf 1-0-0 8-6-0 11-0-0 14-9-0 19-8-14 24-0-0 27-4-7 35-0-0 6-0- 0-0 8-6-0 2-6-0 3-9-0 4-11-14 4-3-2 3-4-7 7-7-9 0-0 �1 6 5x6 = 2x3 I 4.00 12 5 9v3 A 21 5x8 MT18HS = 3x4 = 6 22 7 13 12 3x6 = 3x5 = 5x8 MT18HS = 3x12 2.00 12 14-9-0 24-6-8 10-5-8 Scale = 1:61.3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) 0.75 11-12 >563 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -1.21 11-12 >348 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(CT) 0.35 9 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 155 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Horz 2=-117(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3209/2102,.3-4=-3006/2024, 4-5=-3022/2080, 5-6=-3022/2080, 6-7=-4643/2994, 7-8=-5324/3364,8-9=-5751/3700 BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478 WEBS 3-13=-425/410, 4-13=-354/571, 4-12=-362/617, 5-12=-269/279, 6-12=-1034/712, 6-11=-373/892, 7-11=-897/1523, 8-11=-404/435 Structural wood sheathing directly applied or 2-7-7 oc purlins. Rigid ceiling directly applied or 2-2-0 oc bracing. NOTES - I) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss.to bearing plate capable of withstanding 825 lb uplift at joint 2.and 825.Ib uplift at joint 9. WalterP. Finn PE-No.22839: MiTek USA,1nc. FL Cart 6034 6964 Parke East Blvd. Tampa FL 33610' Date:: April 3,2019 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M?EK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M'iTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information' ',available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36616 Job Truss Truss Type City Ply THE WINDSOR T16686492 M11392 A2 SPECIAL 1 1 + Job Reference (optional) %,namuers i russ, mc., ion rierce, rL 6.Z41.) S uec b Zu16 Mi I eK IncUSInes, Inc. vvea Apr 3 iu:1 ts:4b zui 9 rage 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-fUQsDnveONArLMv_eQr4bNRPdbE8UbsJNvWdWhzUSce 1-0-0 8-6-0 13-0-0 14-9-0 22-0-0 27-4-7 35-'0-0 6-0- 0-0 8-6-0 U 1-9-0 7-3-0 5-4-7 7-7-9 0-0 Scale = 1:61.3 5x6 = 3x4 = 5x8 -4.00 12 4 21 5 22 6 12 3x4 = 5x8 = 3x12 Zz 3x6 = 2.00 12 10-0-0 14-9-0 22-0-0 24-6-8 35-0-0 10-0-0 4-9-0 ' 7-3-0 2-6-8 10-5-8 Plate Offsets (X,Y)— [2:0=0-6,Edge], [6:0-4-0 0-2-31, [8:0-.1 -1 5,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) 0.72 10 >585 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.94 10-19 >447 180 MT18HS 244/190 BCLL' 0.0 * Rep Stress Incr YES WB 0.86 Horz(CT) 0.34 8 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 8=1349/0-8-0 Max Horz 2=136(LC 11) Max Uplift 2=-825(LC 12), 8=-825(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3211/2064,,3-4=-3017/1998, 4-5=-2580/1800, 5-6=-3379/2225, 6-7=-5242/3250, 7-8=-5759/3665 BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=-1990/3441, 8-10=-3410/5485 WEBS 3-13=-420/418, 4-13=-427/688, 4-12=-337/551, 5-12=-777/605, 5-11=-465/925, 6-11=-391/277; 6-1 0=-1 318/2268, 7-10=-503/530 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0,18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load rionconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at. joint 8. Walter P. Finn PE'I4bZ838_. kTak USA; Inc. FLCerf 6634 6904 Parke East Blvd.•TampaFL 33616 April 3,2019 ® WARNING -Vedl y design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE. PAGE MII-7473 rev. 10/03(2015 BEFORE, USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a:truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information. available from Truss Plate Institute,218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610' Job Truss Truss Type Qty Ply THE WINDSOR T16686493 M11392 A3 SPECIAL 1 1 Job Reference (optional) t;namoers truss, Inc., con coerce, t-L t5.z4u s uec . o zuid mi I eK inaustrles, mc.. vvea t+pr a iun n:4o zui a rage i ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7g_FQ7wGngliyWTBC7MK8a_bG_aPD3iScZGA27zUScd �1-0-0, 8-6-0 15-0-0 20-0-0 24 6-8 27 4 7 35-0-0 36-0-9 -0-0 8-6-0 6-6-0 5-0-0 4-6-8 2-9-15 7-7-9 0-0 �1 Scale=1:62.3 4.00 12 5x6 = 45 = 5 6 14 13 3x5 = 2x3 II 5x6 = 3x12 = 2.00 12 8-6-0 14-9-0 20-0-0 24-6-8 35-0-0 86-0 6-3-0 5-3-0 4-6-8 10-5-8 Plate Offset_s_(X,Y)-- [2:0-1-6,Edge], [3:0-3-0,Edge], [8:0-3-0,0-3-4], [9:0-1-15,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) )Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL . 1.25 TC 0.60 Vert(LL) 0.73 11 >572 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.97 11-20 >432 180 MT18HS 244/190 BCLL 0.0 Rep Stress IncrYES WB 0.83 Horz(CT) 0.36 9 n/a n/a BCDL 10.0 Code. FBC2017/TPI2014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-12 REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Hori 2=-155(LC 10). . Max Uplift 2=-825(LC 12), 9=-825(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3256/2031, 4-5=-2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=-5320/3257, 8-9=-5720/3554 BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=-2935/5103, 9-11=-3302/5445 WEBS 4-14=0/329, 4-13=-897/636, 5-12=-316/661, 6-12=-317/616, 7-12=-272711643, 7-11 =-1 072/1939, 8-11=-390/391 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to.prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.11 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 9.. Walter P. Finn PE No.22839. MiTek USA, Inc. FL Ced 6694 '6904 Parke East Blvd. Tampa,FL 33610' April 3,2019 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE. USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not • a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage,delivery, erection and bracing of trusses and truss systems, see . . ANSI1TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686494 M11392 A4 SPECIAL 1 1 Job Reference (optional) L:namders truss, Inc., rOrt coerce, rL 6.241.1 s uec 6 2u16 MI I eK Inaustries, Inc. wed Apr 3 1U:16:4t 2U19 rage 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-bsYdeTxuY_QZaf2NmrtZhoWmCOwdyTccgD7kazzUScc 1-0-0, 8-6-0 14-9-0 17-0-0 18-0-q 24-6-8 27 4-7 35-0-0 16-0-9 i-0-0' 8-6-0 6-3-0 ' 2 3-0 1-0-0' 6-6-8 2-9-15 7-7-9 0-0 4.00 12 5x6 = 4x6 = 2x3 11 6 .7 Scale=1:62.3 ig2 m rr 16 15 6x10 3x5 = 2x3 II 5x8 = 2.00 12 3x12 = 8-6-0 14-9-0 18-0-0 24-6-8 35-0-0 8-6-0 6-3-0 8 0 6-6-8 10-5-8 Plate Offsets (X,Y)-- [2:0-1-6,Edge], [9:0-3-0,Edge], [11:0-1-15,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59, Vert(LL) 0.80 13 >528 240 _ MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.05 13 >400 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.98 Horz(CT) 0.39 11 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 172 lb FT = 20% LUMBER- . BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-14 oc purlins. BOT CHORD2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 8-14 REACTIONS. (lb/size) 2=1349/0-8-0, 11=1349/0-8-0 Max Horz 2=-175(LC 10) Max Uplift 2=-825(LC 12), 11=-825(LC 12) FORCES. (lb) -'Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3253/1989,.3-5=-2435/1560, 5-6=-2399/1639, 6-7=-2217/1501, 7-8=-2380/1519, 8-1 0=-5361/3228, 10-11 =-5716/3480 BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154, 11-13=-3232/5441 WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-163/427, 6-14=-309/604, 6-15=-315/409, 8-14=-3146/1901, 8-13=-1034/1946, 10-13=-343/333 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE.7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf;, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.' II; Exp C; Encl., GCpi=0:18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip D6L=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other jive loads. 6) ' This truss has been designed for a live load'of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 11. . WalterP. FinnP.ENo:2280, MIT6k USA; Inc. FL Oirf 6634. 6904 Parke East Blvd. Tampa FL 33610' Dpte: April 3,2019 -- AWARNBVG-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE.PAGE MI1•7473 rev. 10/03/2015.BEFORE USE. ��' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686495 M11392 A5 SPECIAL 16 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:48 2019 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-435?rpyWJIYQCpdZKYOoD?3uUoGOfi_VI3tlH7?zUScb �1-0-0, 8-6-0 14-9-0 17-6 0 24-6 8 27-4-7 35-0-0_ 6-0-9 0-0 8-6-0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 0-0 �1 d 5x8 MT18HS 11 4.00 12 14 13 Scale=1:60.3 3x5 = 2x3 II 5x10 = 3x12 zz 2.00 12 I�I N r d 8-6-0 14-9-0 24-6-8 35-0-0 8-6-0 6-3-0 9-9-8 10-5-8 Plate Offsets (X,Y)— [2:0-1-6,Edge], [8:0-3-0,Edge], r10:0-1-15,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) 0.80 12-13 >526 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -1.28 12-13 >329 .180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.74 HOrz(CT) 0.36 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 31 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. 1-4,8-11: 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD2x4 SP M 30 WEBS 1 Row at midpt 6-12 WEBS 2x4 SP No.3 *Except* 6-12: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 10=1349/0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-825(LC 12), 10=-825(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=-2397/1763, 6-7=-5452/3624, 7-9=-5398/3482, 9-10=-5732/3689 BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, 12-13=-1223/2137, 10-12=-3431/5459 WEBS 3-14=0/303, 3-13=-861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526, 7-12=-323/388, 9-12=-321/306 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 10. Walter P. Finn PE 'No.2Y699; MiTek USA, Inc. FL Cerf 6634, 6904 Parke East Blvd. Tampa FL 336117 Date:: April 3,2019 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK REFERENCE PAGE M11-7473 rev. 10103/2015 BEFORE, USE Design valid for use only with MITekO connectors. This design is based, only upon parameters shown, and is, for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek° Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686496 M11392 ATA COMMON 5 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.24U s Uec 8 ZU18 MI I eK InousVles, Inc. Weo Apr J 1U:18:49 ZU19 rage 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-YFfN29y84bgHpzCmtGv1 mDc6jCfJQT9u1XUrfSzUSca i1-0-0 8-4-0 12-11-0 171 0 22-1-0 26-8-0 35-0-0 36-0-A .-0-0 8-4-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 -0-0 4.00 12 45 = 6 Scale=1:59.5 1 � I 0 17 — 15 14 "" 12 3x6 = 2x3 11 4x6 = 3x8 = 2x3 11 3x8 = 4x6 = 8-4-0 12-11-0 22-1-0 26-8-0 8-4-0 4-7-0 9-2-0 4-7-0 Plate Offsets (X,Y)— [2:0-0-2,Edge],[10:0-0-2,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.33 14-15 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.64 14-15 >652 180 BCLL 0.0 Rep Stress Incr YES WS 0.59 Horz(CT) 0.13 10 We n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS 3x6 = PLATES GRIP MT20 244/190 Weight: 166 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-2-15 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1399/0-8-0, 10=1399/0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-775(LC 12), 10=-775(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=-2801/1739, 7-9=-2807/1637, 9-10=-3404/1963 BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188, 10-12=-1739/3188 WEBS 6-14=-560/968, 9-14=-681/524, 6-15=-560/968, 3-15=-681/524 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) =1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at joint 10. Walter P. Finn PE'No.22638; MiTek USA; Inc. FL dart 6634 6904 Parke EasfBlvd. Tampa FL 33610 Dater April 3,2019 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev. 1010312015.BEFORE,USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is. for an Individual building component, not atruss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information, available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686497 M11392 B COMMON 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:51 2019 Page 1 ID:_kftGCA6bx7j2Sy1HDXFw7ye3KX-UenBTr PcDw_3HM8?hyVrehWA?QSuN?BlrzxjKzUScY i1-0-0, 8-3-5 140-0 , 17-6-0 21-0-0 26-8-11 35-0-0 a6-0-0, i-0-0' 8-3-5 5-8-11 3-6-0 3-6-0 5.8-11 8-3-5 -0-0 6 4.00 12 3x6 = 17 — 15 14 — 12 Scale = 1:59.3 2x3 I 3x6 = 3x4 = 3x4 - 3x6 = 2x3 II 3x4 = 3x4 — 8-3-5 14-0-0 21-0-0 26-8-11 35-0-0 8-3-5 5-8-11 7-0-0 5-8-11 8-3-5 Plate Offsets (X,Y)-- [2:0-2-6,Edge], [6:0-3-0,Edge], [10:0-2-6,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.11 14-15 >766 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.24 17-20 >715 180 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 149 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0. (lb) - Max Harz 2=-179(LC 10) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC 12) Max Grav All reactions 250 lb or less at joints) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC 1) FORCES. (lb) - Max. Comp./Max. Ten.'- All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-945/572, 5-6=-181/256, 6-7=-181/258, 9-10=-945/574 BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-14=-393/858, 10-12=-393/858 WEBS 3-17=-5/301, 3-15=-819/591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592, 9-12=-5/301 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-secor d gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-M to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = IO.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 Ib uplift at joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10. WalterP. Finn PE'No.228W MiTek USA, Inc. FL Cerf 664 6904 Parke EasfBlvd; Tampa FL 33810' Dater April 3,2019 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MIT&C REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE.USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not �• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance: regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria; VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686498 M11392 BHA BOSTON HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:52 2019 Page 1 ID:_kf,GCA6bx7j2Syl HDXFw7ye3KX-ygLWhB?l MW2rgRxLZOTkOrEfFPjAdpvL_VjVGnzUScX 15-6-0 21-M 1-0-0 7-0-0 11-6-0 13-6-01 -0 17-6-0 1&6-0 21-0-0' 23-6-0 25-6-0 2&0-0 35-0-0 6-0-0 -0-0 7-0-0 2-0-0 2-0-0 2-0-0 0-0- 1E-0 2-0-0 2-0-0 1-6-00.6- 2-0-0 2-0-0 2E-0 7-0-0 -0-0 Scale = 1:62.4 4.00 12 4x4 = 57 15 58 17 56 12 59 3x6 55 9 20 54 8 80 22 3x6 5x12 =53 4 6 x6 = 3x4 2451 26 5x12 3 11 18 19 1 23 697 63 14 52 ,n1 2 28 29 N N Im 6 35 42 43 34 44 33 45 46 47 48 32 49 31 50 51 30 0 3x6 = 6x8 = 6x8 = 3x6 = 3x4 = 3x4 = 7-0-0 14-0-0 21-0-0 28-0-0 35-0-0 7-0-0 7-0-0 7-0-0 7-0-0 7-0-0 Plate Offsets (X,Y)-- [3:0-64,0-1-121, [32:0-3-8,0-3-0) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 208 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD . Structural wood sheathing directly applied or 5-3-13 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32 JOINTS 1 Brace at Jt(s): 11, 19, 16, 7,23 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=179(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8), 28=434(LC 8) Max Grav All reactions 250 lb or less at joints) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1). 28=626(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1692/1103, 34=-105/259, 27-28=-1129/710, 3-5=-441/520, 5-7=-436/514, 7-10=436/514, 10-11=-436/514, 11-13=-436/514, 13-16=-436/514, 16-18=-436/514, 18-19=-436/514, 19-21=-382/412, 21-23=-382/412, 23-25=-382/412, 25-27=-387/418 BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039 WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=-810/782, 19-32=-772/745, 27-32=-1484/1044, 9-10=-463/453, 20-21=-462/454 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at 7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 Ib.down and 206 lb up at 17-11-4, 158 lb down and 206 lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at 25-114, and 158 lb down and 206 lb up at 27-114 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, (39 lb down at 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at 19-11-4, 69 lb down at 21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 69 lb down at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Walter P. Finn PE-No22839' MiTek USA; Inc. FL Carf 6634 6904 Parke East Blvd: Tampa.FL 33610' Date:: an ar ® WARNING - Vedry design' parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE, USE. ' Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 April 3,2019 Job Truss Truss Type Qty Ply THE WINDSOR T16686498 M11392 BHA BOSTON HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:53 2019 Page 2 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-QOvuuX?f7gAilaWX65_zw3mq-p3PMG9UD9S2oDzUScW LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 36-39=-20, 1-3=-54, 3-15=-54, 15-27=-54, 27-29=-54 Concentrated Loads (lb) Vert: 35=-373(F)30=-23(F)42=-23(F)43=-23(F)44=-23(F)45=-23(F)46=-23(F)47=-23(F)48=-23(F)49=-23(F)50=-23(F)51=-23(F) 52=-169(F) 53=-118(F) 54=-118(F)55=-118(F)56=-118(F) 57=-118(F)58=-118(F)59=-118(F)60=-118(F)61=-118(F)62=-118(F)63=A 18(F) A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK REFERENCE PAGE MII-7473 rev. 1 a/03/2015 BEFORE. USE. Design valid for use only with MlTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, note a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance. regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety /nformetlon, .available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686499 M11392 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:54 2019 Page 1 ID: _kfiGCA6bx7j2Syl HDXFw7ye3KX-uDTG6sOHu81Zwk5jgpVCTGJuxDNe5e1 eRpCcKfzUScV n1-0-0 7-0-0 14-11-0 21-5-2 28-0-0 35-0-0 $6-0-q 0-0 7-0-0 7-11-0 6-6-2 6 6 14 7-0-0 0-0 �1 d 5x12 MT18HS = 4.00 12 3x5 II 3x6 = 4x8 = 3 22 23 24 25 4 26 27 5 28 629 30 31 3x4 = 4x8 = 32 7 15 33 34 14 35 13 36 37 38 1239 11 40 41 10 2x3 II 3x6 = 5x14 = 3x4 = 4x6 = 2x3 11 7-0-0 14-11-0 21-5-2 28-0-0 35-0-0 7-0-0 7-11-0 6-6-2 6-6-14 7-0-0 Scale=1:60.3 3x5 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.30 10-21 >792 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.30 10-12 >812 180 MT18HS 244/190 . BCLL 0.0 Rep Stress Incr NO WB 1.00 HOrz(CT), 0.09 8 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 153 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 *Except* WEBS 4-13: 2x6 SP No.2 REACTIONS. (lb/size) 2=750/0-8-0, 13=3223/0-8-0, 8=1225/0-8-0 Max Horz 2=-78(LC 6) Max Uplift 2=-448(LC 8), 13=-2442(LC 8), 8=-1159(LC 8) Max Grav 2=755(LC 17), 13=3223(LC 1). 8=1225(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1534/729, 3-4=-1052/1347, 4-6=-1052/1347, 6-7=-1946/1834, 7-8=-2978/2565 BOT CHORD 2-15=-586/1423, 13-15=-596/1464, 12-13=-1710/1946, 10-12=-2359/2830, 8-10=-2329/2789 WEBS 3-15=-159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=-3504/3050, 6-12=-430/666, 7-12=-940/731, 7-10=-489/690 Structural wood sheathing directly applied or 3-9-5 oc purlins. Rigid ceiling directly applied or 4-6-8 oc bracing. 1 Row at mjdpt 6-13 2 Rows at 1/3 pts 3-13 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at joint 13 and 1159 lb uplift at joint 8. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at 7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at. 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-11-4. 90 lb down and 155 lb up at 19-11-4, 90 lb down and 155 lb up at 21-11-4, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-11-4, and 203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb down and 3 lb up at 11-0-12, 63 lb down and 3.Ib up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at 17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-11-4, 63 lb down and 3 lb up at 21-11-4, 63 lb down and 3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard WalterP. Finn PE No.22839, MiTek usA, Inc. FL Cerf e634, '6904 Parke East Bivd. Tampa FL 336i0 Date:. ,&WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage,delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 April 3,2019 Job Truss Truss Type city Ply THE WINDSOR T16686499 M11392 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:54 2019 Page 2 I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-uDTG6sOHu8IZwk5jgpVCTGJuxDNe5el eRpCcKfzUScV LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-54, 7-9=-54, 16-19=-20 Concentrated Loads (lb) Vert: 3=-147(B) 7=-147(B) 15=-452(B) 13=-40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=-90(B) 28=-90(B) 30=-90(B) 31=-90(B) 32=-90(B) 33=-40(B) 34=-40(B) 35=-40(B) 36=-40(B) 37=-40(B) 38=-40(B) 39=-40(B) 40=-40(B) 41=-40(B) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. f0/03�2015 BEFORE.USE. �' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see • ANSI/TPH Qualify Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information. available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE WINDSOR T16686500 M11392 J1 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:55 2019 Page 1 . ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-MPOeJC1 vfRQQXufvEWOR?UrEfds3pKrngTz9t6zUScU -1-0-0 1-0-0 1-0-0 1-0-0 3x4 = Scale = 1:6.1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 5 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 5 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical Max Horz 2=48(LC 12) Max Uplift 3=-4(LC 9), 2=-140(LC 12) Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. Walter P. Finn PE N6.22638', MiTek USA; Inc. FL 6rf 6634. 6904 Parke East Blvd. Tampa FL 331i10 Date:: April 3,2019 A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage,delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City . Ply THE WINDSOR T16686501 M11392 J3 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:55 2019 Page 1 ID:_kfiGCA6bx7jj2Syl HDXFw7ye3KX-MPOeJC1 vfRQQXufvE WOR?UrEYdgQpKmgTx9t6zUScU -1-0-0 3-0-0 • 1-0-0 3-0-0 Scale = 1:9.4 3x4 = 3-0-0 3-0-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 11 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12) Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-0-0 to 2-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint 2 and 4 lb uplift at joint 4. Walter P. Finn FENo.221l MiTek USA; Inc. Ft. 6erE6634 6904 Parka East Blvd. Tampa FL 33610 Date:: April 3,2019 AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. '` Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE WINDSOR T16686502 M11392 J5 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 1-0-0 3x4 = 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:56 2019 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-rbal WY2XQIYH92E6oEXgYhOGnO2hYn5wv7hiPYzUScT 5-0-0 5-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.07 4-7 >863 240 TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.06 4-7 >964 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP ND.3 REACTIONS. (lb/size) 3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical Max Horz 2=123(LC 12) Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12) Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:12.7 PLATES GRIP MT20 244/190 Weight: 17 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9 lb uplift at joint 4. Walter P. Finn PE 146.22638', MiTek USA, Inc. FL Cerf 6634 6904 Parke East Blvd. Tampa FL 33610' Date:, April 3,2019 ,&WARNING - Vedty design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11711-7473 rev. la (0312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686503 M11392 J7 MONO TRUSS 24 1 • Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL -1-0-0 3x4 = 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:57 2019 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-Jo8Pku29B3h8nCplLx2v5vxV WQSnHEL48nQGx_zUScS Scale: 3/4"=1' LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) 0.17 4-7 >494 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.19 4-7 >447 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 23 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=165/Mechanical, 2=315/0-8-0, 4=88/Mechanical Max Horz 2=161(LC 12) Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC 12) Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) "'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at joint 2 and 12 lb uplift at joint 4. Walter P. Finn FE No.22839', MiTek USA, Inc. FL 6rf6634 6904 Parke East Blvd. Tampa FL 33610 Date:. April 3,2019 ,& WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 101=2015 BEFORE USE. • Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage,delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T16686504 M11392 KJ7 MONO TRUSS 4 1 ' Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:57 2019 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-Jo8Pku29B3h8nCplLx2v5vxZmQVpHBb48nQGx zUScS -1-5-0 6-8-12 9-10-1 1-5-0 6-8-12 3-1-5 3x4 = 5 3x4 = Scale = 1:20.6 6-8-12 9-10-1 6-8-12 3-1-5 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.04 7-10 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.08 7-10 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.24 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 38 Ito FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=127/Mechanical, 2=379/0-11-5, 5=461/Mechanical Max Horz 2=192(LC 8) Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=-238(LC 8) Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-838/366 BOT CHORD 2-7=-487/798, 84=487/798 WEBS 3-7=0/307, 3-6=-920/561 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at joint 2 and 238 lb uplift at joint 5. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-4=7133(F=-39, B=-39), 8=0(F=10, B=10)•to-5=-4g(F=-15, B=-15) Walter P. Finn PE No.22639. MiTek USA,Inc. FL 6rf66U 6964 Parke East Blvd. Tampa FL 33610 Date: April 3,2019 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE ' Design valid for use only with MiTek®connectors. This design is based only upon parameters shown, and Is for an Individual building component, not ` a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance. regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Symbols Numbering System General Safety Notes PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y 4 offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) Failure to Follow Could Cause Property Damage or Personal Injury Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system, e.g. and fully embed teeth. TOP CHORDS diagonal orX-bracing, is always required. See BCSI. 0_� c1-2 c2-3 2. Truss bracing must be designed by an engineer. For WEBS �a 4 4 wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I T p O bracing should be considere d. , V3 ��� a� N O 3. Never exceed the design loading shown and never 0 U stack materials on inadequately braced trusses. 00 a0 4. Provide copies of this truss design to the building For 4 x 2 orientation, locate c7-8 c6a cs s 0 BOTTOM CHORDS designer, erection supervisor, property owner and plates 0- yid' from outside all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully. Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from . Plate location details available in MiTek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. software or upon request. NUMBERS/LETTERS. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. ^ PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted, this design is not applicable for ICC-ES Reports: use with fire retardant, preservative treated, or green lumber. The first dimension is the plate 10. Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 responsibility of truss fabricator. General practice is to ' to slots. Second dimension is ER-3907, ESR-2362, ESR-1397, ESR-3282 camber for dead load deflection. the length parallel to slots. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless Otherwise shown. in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values g y 14. Bottom chords require lateral bracing at h r spacing, or less, if no ceiling is installed, unless otherwise noted. BEARING established by others. 15. Connections not shown are the responsibility of others. Indicates location where bearings 16. Do not cut or alter truss member or plate without prior (supports) occur. Icons vary but © 2012 MiTek® All Rights Reserved approval of an engineer. reaction section indicates joint number where bearings occur. 17. Install and load vertically unless indicated otherwise. Min size shown is for crushing only. 6-a 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with Industry Standards: W1 project engineer before use. ANSI/TPI1: National Design Specification for Metal 19. Review all portions of this design (front, back, words Plate Connected Wood Truss Construction. and pictures) before use. Reviewing pictures alone DSB-89: Design Standard for Bracing. a is not sufficient. BCSI: Buildin Com onent Safe Information, 9 P tY MiTek 20. Desi n assumes manufacture in accordance with g Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing & Bracing of Metal Plate ' Connected Wood Trusses. MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015