HomeMy WebLinkAboutTrussMiTek®
RE: M11392 MiTek USA, Inc.
THE WINDSOR 6904 Parke East Blvd.
Tampa, FL 33610-4115
Site Information:
Customer: Wynne Dev Corp Project Name: M11392
Lot/Block:- Model: 71 Carlton 3 Bedroom Rear Porch
Address: unknown Subdivision,
City: St. Lucie County State: FL
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TPi2014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
1 T16686490 a 4/3/2019
2 T16686491 a1 4/3/2019
3 T16686492 a2 4/3/2019
4 T16686493 a3 4/3/2019 FIL
5 T16686494 a4 4/3/2019 E COPY .
6 T16686495 a5 4/3/2019
7 T16686496 ata 4/3/2019
8 T16686497 b 4/3/2010
9 T16686498 bha 4/3/2019
10 T16686499 gra 4/3/2019 ��'���® F:OR
11 T16686500 j1 4/3/2019 �. wwAAPL��rYCFE
12 T16686501 j3 4/3/2019 F C;oM
13 T16686502 j5 4/3/2019 O®®C®utq-ry
14 T16686503 j7 4/3/2019 S-r. LUC1E
15 T16686504 kj7 4/3/2019 BOCCj
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision
based on the parameters provided by Chambers Truss.
Truss Design Engineer's Name: Finn, Walter
My license renewal date for the state of Florida is February 28, 2021.
Florida COA: 6634
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that -the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into.account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSIfrPI 1, Chapter 2.
1 of 1
EN SF•'Ai
i
:• No 22839
��� STATE OF •:��
.�♦
Walter P. Finn PE No.22839
MiTek USA, Inc: FL Cert 6634
6904 Parke East Blvd: Tampa FL 33610 April 03, 2019
Finn, Walter
Job
Truss
Truss Type
Qty
Ply
THE WIND OR
T16686490
M11392
A
HIP
1
1
•
Job Reference (optional)
o.wus.uec o,zvio mllex Inaustrles, Inc. yvep Apr JIUn6:4J ZUIU rageI
ID;_kfiGCA6bx7j2Syl HDXFw7ye3KX-j516o6uNUlw752lcX?ocWyM5YnfBOhBOwcl WRozUScg
1-0-0 6-10-14 9-0-0 . 14-11-0 20-2-13 26-0-0 28-1-2 35-0-0 6-0-
-0-0 6-10-14 2-1-2 S-11-0 5-3-13 5-9-3 2-1-2 6-10-14 -0-0
Scale = 1:60.5
4x8 2x3 II . 3x6 = 4x4 = 4x8 =
4.00 12 2x3.
2x3 \\ 4 26 5. 6 7 27 8 9
m1 2
0
3x4 =
3
25 28
24 29
17. 16 15 14 13. 12
3x4 3x6 — 6x8 = 3x4 = 3x6 — 3x4 =
9-0-0
14-11-0
20-2-13
26-0-0
35-0-C
9-0-0
5-11-0
5-3-13
5-9-3
9-0-0
3x5 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.57
Vert(LL)
0.42 12-23
>572
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.47
Vert(CT)
0.37 12-23
>659
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.94
Horz(CT)
0.03 10
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 161 lb FT = 206/6
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-5-1 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=433/0-8-0, 15=1596/0-8-0, 10=669/0-8-0
Max Horz 2=-97(LC 10)
Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12)
Max Grav 2=467(LC 17), 15=1596(LC 1), 10=685(LC 22)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-639/108, 3-4=-396/0, 4-5=-967/776, 5-7=-967/776, 7-8=-454/938, 8-9=-1009/1884,
9-10=-1265/2154
BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-1586/938, 10-12=-1971/1174
WEBS 3-17=-372/461, 4-17=-272/451, 4-15=-1087/1002, 5-15=-336/386, 7-14=-766/399,
8-14=-580/997, 8-12=-958/447, 9-12=-358/600, 7-15=-1329/2190
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE.7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Extedor(2) 9-0-0 to
13-11-6, Interior(l) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf.bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 Ito uplift at joint 2, 1439 lb uplift at
joint 15 and 799 lb uplift at joint 10.
WalterP, Finn PE'No.22838;
MiTak USA,'Ine. FL Cert 6634
'6904 Parke East Blvd: Tampa FL" 33619
Date;;
April 3,2019
s.
--
r AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M ITe ICs
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686491
M11392
Al
SPECIAL
1
1
Job Reference (optional)
�numueis i russ, inc., rurr tierce, rL o.Z4U s uec o zuits MI teK Inausines, Inc. vvea Apr J IU:16:44 ZUIU rage 1
ID:_kfiGCA6bz7j2Syl HDXFw7ye3KX-BIsU?Su?F32JCKo5jKr39uFQBuX19198Gn4_EZUSCf
1-0-0 8-6-0 11-0-0 14-9-0 19-8-14 24-0-0 27-4-7 35-0-0 6-0-
0-0 8-6-0 2-6-0 3-9-0 4-11-14 4-3-2 3-4-7 7-7-9 0-0
�1
6
5x6 = 2x3 I
4.00 12 5
9v3 A 21
5x8 MT18HS =
3x4 =
6 22 7
13 12
3x6 = 3x5 = 5x8 MT18HS = 3x12
2.00 12
14-9-0
24-6-8
10-5-8
Scale = 1:61.3
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.63
Vert(LL)
0.75 11-12
>563
240
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.91
Vert(CT)
-1.21 11-12
>348
180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WB 0.77
Horz(CT)
0.35 9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 155 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0
Max Horz 2=-117(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3209/2102,.3-4=-3006/2024, 4-5=-3022/2080, 5-6=-3022/2080, 6-7=-4643/2994,
7-8=-5324/3364,8-9=-5751/3700
BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478
WEBS 3-13=-425/410, 4-13=-354/571, 4-12=-362/617, 5-12=-269/279, 6-12=-1034/712,
6-11=-373/892, 7-11=-897/1523, 8-11=-404/435
Structural wood sheathing directly applied or 2-7-7 oc purlins.
Rigid ceiling directly applied or 2-2-0 oc bracing.
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss.to bearing plate capable of withstanding 825 lb uplift at joint 2.and 825.Ib uplift at
joint 9.
WalterP. Finn PE-No.22839:
MiTek USA,1nc. FL Cart 6034
6964 Parke East Blvd. Tampa FL 33610'
Date::
April 3,2019
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M?EK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with M'iTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information' ',available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36616
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T16686492
M11392
A2
SPECIAL
1
1
+
Job Reference (optional)
%,namuers i russ, mc., ion rierce, rL 6.Z41.) S uec b Zu16 Mi I eK IncUSInes, Inc. vvea Apr 3 iu:1 ts:4b zui 9 rage 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-fUQsDnveONArLMv_eQr4bNRPdbE8UbsJNvWdWhzUSce
1-0-0 8-6-0 13-0-0 14-9-0 22-0-0 27-4-7 35-'0-0 6-0-
0-0 8-6-0 U 1-9-0 7-3-0 5-4-7 7-7-9 0-0
Scale = 1:61.3
5x6 = 3x4 = 5x8
-4.00 12 4 21 5 22 6
12
3x4 =
5x8 =
3x12 Zz
3x6 =
2.00 12
10-0-0
14-9-0
22-0-0
24-6-8
35-0-0
10-0-0
4-9-0
'
7-3-0
2-6-8
10-5-8
Plate Offsets (X,Y)—
[2:0=0-6,Edge], [6:0-4-0 0-2-31, [8:0-.1 -1 5,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.66
Vert(LL)
0.72 10 >585 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.95
Vert(CT) -0.94 10-19 >447 180
MT18HS
244/190
BCLL' 0.0 *
Rep Stress Incr YES
WB
0.86
Horz(CT)
0.34 8 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly
applied or 2-6-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied
or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 8=1349/0-8-0
Max Horz 2=136(LC 11)
Max Uplift 2=-825(LC 12), 8=-825(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3211/2064,,3-4=-3017/1998, 4-5=-2580/1800, 5-6=-3379/2225, 6-7=-5242/3250,
7-8=-5759/3665
BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=-1990/3441,
8-10=-3410/5485
WEBS 3-13=-420/418, 4-13=-427/688, 4-12=-337/551, 5-12=-777/605, 5-11=-465/925,
6-11=-391/277; 6-1 0=-1 318/2268, 7-10=-503/530
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0,18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load rionconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at.
joint 8.
Walter P. Finn PE'I4bZ838_.
kTak USA; Inc. FLCerf 6634
6904 Parke East Blvd.•TampaFL 33616
April 3,2019
® WARNING -Vedl y design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE. PAGE MII-7473 rev. 10/03(2015 BEFORE, USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a:truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information. available from Truss Plate Institute,218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610'
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686493
M11392
A3
SPECIAL
1
1
Job Reference (optional)
t;namoers truss, Inc., con coerce, t-L t5.z4u s uec . o zuid mi I eK inaustrles, mc.. vvea t+pr a iun n:4o zui a rage i
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7g_FQ7wGngliyWTBC7MK8a_bG_aPD3iScZGA27zUScd
�1-0-0, 8-6-0 15-0-0 20-0-0 24 6-8 27 4 7 35-0-0 36-0-9
-0-0 8-6-0 6-6-0 5-0-0 4-6-8 2-9-15 7-7-9 0-0
�1
Scale=1:62.3
4.00 12 5x6 = 45 =
5 6
14 13
3x5 = 2x3 II 5x6 = 3x12 =
2.00 12
8-6-0 14-9-0
20-0-0
24-6-8
35-0-0
86-0 6-3-0
5-3-0
4-6-8
10-5-8
Plate Offset_s_(X,Y)--
[2:0-1-6,Edge], [3:0-3-0,Edge], [8:0-3-0,0-3-4], [9:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) )Well Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL . 1.25
TC 0.60
Vert(LL)
0.73 11 >572 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-0.97 11-20 >432 180
MT18HS
244/190
BCLL 0.0
Rep Stress IncrYES
WB 0.83
Horz(CT)
0.36 9 n/a n/a
BCDL 10.0
Code. FBC2017/TPI2014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 7-12
REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0
Max Hori 2=-155(LC 10). .
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3256/2031, 4-5=-2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=-5320/3257,
8-9=-5720/3554
BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=-2935/5103,
9-11=-3302/5445
WEBS 4-14=0/329, 4-13=-897/636, 5-12=-316/661, 6-12=-317/616, 7-12=-272711643,
7-11 =-1 072/1939, 8-11=-390/391
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to.prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.11 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface..
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 9..
Walter P. Finn PE No.22839.
MiTek USA, Inc. FL Ced 6694
'6904 Parke East Blvd. Tampa,FL 33610'
April 3,2019
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE. USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage,delivery, erection and bracing of trusses and truss systems, see . . ANSI1TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686494
M11392
A4
SPECIAL
1
1
Job Reference (optional)
L:namders truss, Inc., rOrt coerce, rL 6.241.1 s uec 6 2u16 MI I eK Inaustries, Inc. wed Apr 3 1U:16:4t 2U19 rage 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-bsYdeTxuY_QZaf2NmrtZhoWmCOwdyTccgD7kazzUScc
1-0-0, 8-6-0 14-9-0 17-0-0 18-0-q 24-6-8 27 4-7 35-0-0 16-0-9
i-0-0' 8-6-0 6-3-0 ' 2 3-0 1-0-0' 6-6-8 2-9-15 7-7-9 0-0
4.00 12 5x6 = 4x6 =
2x3 11 6 .7
Scale=1:62.3
ig2 m rr
16 15 6x10
3x5 = 2x3 II 5x8 =
2.00 12
3x12 =
8-6-0 14-9-0 18-0-0 24-6-8
35-0-0
8-6-0 6-3-0 8 0 6-6-8
10-5-8
Plate Offsets (X,Y)--
[2:0-1-6,Edge], [9:0-3-0,Edge], [11:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59,
Vert(LL) 0.80 13 >528 240
_
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT) -1.05 13 >400 180
MT18HS 244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.98
Horz(CT) 0.39 11 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 172 lb FT = 20%
LUMBER- . BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-14 oc purlins.
BOT CHORD2x4 SP M 30 BOT CHORD Rigid ceiling directly applied
or 2-2-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt
8-14
REACTIONS. (lb/size) 2=1349/0-8-0, 11=1349/0-8-0
Max Horz 2=-175(LC 10)
Max Uplift 2=-825(LC 12), 11=-825(LC 12)
FORCES. (lb) -'Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3253/1989,.3-5=-2435/1560, 5-6=-2399/1639, 6-7=-2217/1501, 7-8=-2380/1519,
8-1 0=-5361/3228, 10-11 =-5716/3480
BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154,
11-13=-3232/5441
WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-163/427, 6-14=-309/604,
6-15=-315/409, 8-14=-3146/1901, 8-13=-1034/1946, 10-13=-343/333
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE.7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf;, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.'
II; Exp C; Encl., GCpi=0:18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip D6L=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other jive loads.
6) ' This truss has been designed for a live load'of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface..
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 11. .
WalterP. FinnP.ENo:2280,
MIT6k USA; Inc. FL Oirf 6634.
6904 Parke East Blvd. Tampa FL 33610'
Dpte:
April 3,2019
--
AWARNBVG-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE.PAGE MI1•7473 rev. 10/03/2015.BEFORE USE. ��'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute,. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686495
M11392
A5
SPECIAL
16
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:48 2019 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-435?rpyWJIYQCpdZKYOoD?3uUoGOfi_VI3tlH7?zUScb
�1-0-0, 8-6-0 14-9-0 17-6 0 24-6 8 27-4-7 35-0-0_ 6-0-9
0-0 8-6-0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 0-0
�1
d
5x8 MT18HS 11
4.00 12
14 13
Scale=1:60.3
3x5 = 2x3 II 5x10 = 3x12 zz
2.00 12
I�I N r
d
8-6-0 14-9-0
24-6-8
35-0-0
8-6-0 6-3-0
9-9-8
10-5-8
Plate Offsets (X,Y)—
[2:0-1-6,Edge], [8:0-3-0,Edge], r10:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.81
Vert(LL)
0.80 12-13 >526 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.92
Vert(CT) -1.28 12-13 >329 .180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.74
HOrz(CT)
0.36 10 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 *Except*
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
1-4,8-11: 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD2x4 SP M 30
WEBS
1 Row at midpt 6-12
WEBS 2x4 SP No.3 *Except*
6-12: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 10=1349/0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-825(LC 12), 10=-825(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=-2397/1763, 6-7=-5452/3624, 7-9=-5398/3482,
9-10=-5732/3689
BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, 12-13=-1223/2137, 10-12=-3431/5459
WEBS 3-14=0/303, 3-13=-861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526,
7-12=-323/388, 9-12=-321/306
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
Walter P. Finn PE 'No.2Y699;
MiTek USA, Inc. FL Cerf 6634,
6904 Parke East Blvd. Tampa FL 336117
Date::
April 3,2019
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK REFERENCE PAGE M11-7473 rev. 10103/2015 BEFORE, USE
Design valid for use only with MITekO connectors. This design is based, only upon parameters shown, and is, for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686496
M11392
ATA
COMMON
5
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.24U s Uec 8 ZU18 MI I eK InousVles, Inc. Weo Apr J 1U:18:49 ZU19 rage 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-YFfN29y84bgHpzCmtGv1 mDc6jCfJQT9u1XUrfSzUSca
i1-0-0 8-4-0 12-11-0 171 0 22-1-0 26-8-0 35-0-0 36-0-A
.-0-0 8-4-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 -0-0
4.00 12 45 =
6
Scale=1:59.5
1 �
I
0
17
— 15
14 ""
12
3x6 =
2x3 11
4x6 =
3x8 =
2x3 11
3x8 =
4x6 =
8-4-0
12-11-0
22-1-0
26-8-0
8-4-0
4-7-0
9-2-0
4-7-0
Plate Offsets (X,Y)—
[2:0-0-2,Edge],[10:0-0-2,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Vert(LL)
0.33 14-15
>999
240
TCDL 7.0
Lumber DOL 1.25
BC 0.68
Vert(CT)
-0.64 14-15
>652
180
BCLL 0.0
Rep Stress Incr YES
WS 0.59
Horz(CT)
0.13 10
We
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
3x6 =
PLATES GRIP
MT20 244/190
Weight: 166 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc pudins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-2-15 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1399/0-8-0, 10=1399/0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-775(LC 12), 10=-775(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=-2801/1739, 7-9=-2807/1637,
9-10=-3404/1963
BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188,
10-12=-1739/3188
WEBS 6-14=-560/968, 9-14=-681/524, 6-15=-560/968, 3-15=-681/524
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) =1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at
joint 10.
Walter P. Finn PE'No.22638;
MiTek USA; Inc. FL dart 6634
6904 Parke EasfBlvd. Tampa FL 33610
Dater
April 3,2019
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev. 1010312015.BEFORE,USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is. for an Individual building component, not
atruss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek"
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information, available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686497
M11392
B
COMMON
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:51 2019 Page 1
ID:_kftGCA6bx7j2Sy1HDXFw7ye3KX-UenBTr PcDw_3HM8?hyVrehWA?QSuN?BlrzxjKzUScY
i1-0-0, 8-3-5 140-0 , 17-6-0 21-0-0 26-8-11 35-0-0 a6-0-0,
i-0-0' 8-3-5 5-8-11 3-6-0 3-6-0 5.8-11 8-3-5 -0-0
6
4.00 12
3x6 =
17 — 15 14 — 12
Scale = 1:59.3
2x3 I 3x6 =
3x4 =
3x4 -
3x6 =
2x3 II
3x4 =
3x4 —
8-3-5 14-0-0
21-0-0
26-8-11
35-0-0
8-3-5 5-8-11
7-0-0
5-8-11
8-3-5
Plate Offsets (X,Y)--
[2:0-2-6,Edge], [6:0-3-0,Edge], [10:0-2-6,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.34
Vert(LL)
-0.11 14-15
>766
240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.38
Vert(CT)
-0.24 17-20
>715
180
BCLL 0.0
Rep Stress Incr YES
WB
0.63
Horz(CT)
0.03 10
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 149 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 0-8-0.
(lb) - Max Harz 2=-179(LC 10)
Max Uplift All uplift 100 lb or less atjoint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC
12)
Max Grav All reactions 250 lb or less at joints) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC
1)
FORCES. (lb) - Max. Comp./Max. Ten.'- All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-945/572, 5-6=-181/256, 6-7=-181/258, 9-10=-945/574
BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-14=-393/858, 10-12=-393/858
WEBS 3-17=-5/301, 3-15=-819/591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592,
9-12=-5/301
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-secor d gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-M to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 Ib uplift at
joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10.
WalterP. Finn PE'No.228W
MiTek USA, Inc. FL Cerf 664
6904 Parke EasfBlvd; Tampa FL 33810'
Dater
April 3,2019
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MIT&C REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE.USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance: regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria; VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686498
M11392
BHA
BOSTON HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:52 2019 Page 1
ID:_kf,GCA6bx7j2Syl HDXFw7ye3KX-ygLWhB?l MW2rgRxLZOTkOrEfFPjAdpvL_VjVGnzUScX
15-6-0 21-M
1-0-0 7-0-0 11-6-0 13-6-01 -0 17-6-0 1&6-0 21-0-0' 23-6-0 25-6-0 2&0-0 35-0-0 6-0-0
-0-0 7-0-0 2-0-0 2-0-0 2-0-0 0-0- 1E-0 2-0-0 2-0-0 1-6-00.6- 2-0-0 2-0-0 2E-0 7-0-0 -0-0
Scale = 1:62.4
4.00 12 4x4 =
57 15 58 17
56 12 59
3x6 55 9 20
54 8 80 22 3x6
5x12 =53 4 6 x6 = 3x4 2451 26 5x12
3 11 18 19 1 23 697
63
14
52
,n1 2 28 29 N N
Im
6 35 42 43 34 44 33 45 46 47 48 32 49 31 50 51 30 0
3x6 = 6x8 = 6x8 = 3x6 = 3x4 =
3x4 =
7-0-0 14-0-0 21-0-0 28-0-0 35-0-0
7-0-0 7-0-0 7-0-0 7-0-0 7-0-0
Plate Offsets (X,Y)-- [3:0-64,0-1-121, [32:0-3-8,0-3-0)
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a
BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 208 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD . Structural wood sheathing directly applied or 5-3-13 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32
JOINTS 1 Brace at Jt(s): 11, 19, 16, 7,23
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=179(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8),
28=434(LC 8)
Max Grav All reactions 250 lb or less at joints) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1).
28=626(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1692/1103, 34=-105/259, 27-28=-1129/710, 3-5=-441/520, 5-7=-436/514,
7-10=436/514, 10-11=-436/514, 11-13=-436/514, 13-16=-436/514, 16-18=-436/514,
18-19=-436/514, 19-21=-382/412, 21-23=-382/412, 23-25=-382/412, 25-27=-387/418
BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039
WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=-810/782, 19-32=-772/745,
27-32=-1484/1044, 9-10=-463/453, 20-21=-462/454
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at
joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at
7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb
down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 Ib.down and 206 lb up at 17-11-4, 158 lb down and 206
lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at
25-114, and 158 lb down and 206 lb up at 27-114 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, (39
lb down at 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at
19-11-4, 69 lb down at 21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 69 lb down at 27-11-4 on bottom chord.
The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Walter P. Finn PE-No22839'
MiTek USA; Inc. FL Carf 6634
6904 Parke East Blvd: Tampa.FL 33610'
Date::
an ar
® WARNING - Vedry design' parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE, USE. '
Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek`
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
April 3,2019
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686498
M11392
BHA
BOSTON HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:53 2019 Page 2
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-QOvuuX?f7gAilaWX65_zw3mq-p3PMG9UD9S2oDzUScW
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 36-39=-20, 1-3=-54, 3-15=-54, 15-27=-54, 27-29=-54
Concentrated Loads (lb)
Vert: 35=-373(F)30=-23(F)42=-23(F)43=-23(F)44=-23(F)45=-23(F)46=-23(F)47=-23(F)48=-23(F)49=-23(F)50=-23(F)51=-23(F) 52=-169(F) 53=-118(F)
54=-118(F)55=-118(F)56=-118(F) 57=-118(F)58=-118(F)59=-118(F)60=-118(F)61=-118(F)62=-118(F)63=A 18(F)
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK REFERENCE PAGE MII-7473 rev. 1 a/03/2015 BEFORE. USE.
Design valid for use only with MlTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, note
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance. regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety /nformetlon, .available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686499
M11392
GRA
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:54 2019 Page 1
ID: _kfiGCA6bx7j2Syl HDXFw7ye3KX-uDTG6sOHu81Zwk5jgpVCTGJuxDNe5e1 eRpCcKfzUScV
n1-0-0 7-0-0 14-11-0 21-5-2 28-0-0 35-0-0 $6-0-q
0-0 7-0-0 7-11-0 6-6-2 6 6 14 7-0-0 0-0
�1
d
5x12 MT18HS =
4.00 12 3x5 II 3x6 = 4x8 =
3 22 23 24 25 4 26 27 5 28 629 30 31
3x4 =
4x8 =
32 7
15 33 34 14 35 13 36 37 38 1239 11 40 41 10
2x3 II 3x6 = 5x14 =
3x4 = 4x6 =
2x3 11
7-0-0 14-11-0 21-5-2 28-0-0 35-0-0
7-0-0 7-11-0 6-6-2 6-6-14 7-0-0
Scale=1:60.3
3x5 =
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc)
I/deft
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.94
Vert(LL)
0.30 10-21
>792
240
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.67
Vert(CT)
-0.30 10-12
>812
180
MT18HS
244/190 .
BCLL 0.0
Rep Stress Incr
NO
WB 1.00
HOrz(CT),
0.09 8
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 153 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3 *Except* WEBS
4-13: 2x6 SP No.2
REACTIONS. (lb/size) 2=750/0-8-0, 13=3223/0-8-0, 8=1225/0-8-0
Max Horz 2=-78(LC 6)
Max Uplift 2=-448(LC 8), 13=-2442(LC 8), 8=-1159(LC 8)
Max Grav 2=755(LC 17), 13=3223(LC 1). 8=1225(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1534/729, 3-4=-1052/1347, 4-6=-1052/1347, 6-7=-1946/1834, 7-8=-2978/2565
BOT CHORD 2-15=-586/1423, 13-15=-596/1464, 12-13=-1710/1946, 10-12=-2359/2830,
8-10=-2329/2789
WEBS 3-15=-159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=-3504/3050, 6-12=-430/666,
7-12=-940/731, 7-10=-489/690
Structural wood sheathing directly applied or 3-9-5 oc purlins.
Rigid ceiling directly applied or 4-6-8 oc bracing.
1 Row at mjdpt 6-13
2 Rows at 1/3 pts 3-13
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at
joint 13 and 1159 lb uplift at joint 8.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at
7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at. 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down
and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-11-4. 90 lb down and 155 lb up at
19-11-4, 90 lb down and 155 lb up at 21-11-4, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-11-4, and
203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb
down and 3 lb up at 11-0-12, 63 lb down and 3.Ib up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at
17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-11-4, 63 lb down and 3 lb up at 21-11-4, 63 lb down and
3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
WalterP. Finn PE No.22839,
MiTek usA, Inc. FL Cerf e634,
'6904 Parke East Bivd. Tampa FL 336i0
Date:.
,&WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage,delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
April 3,2019
Job
Truss
Truss Type
city
Ply
THE WINDSOR
T16686499
M11392
GRA
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:54 2019 Page 2
I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-uDTG6sOHu8IZwk5jgpVCTGJuxDNe5el eRpCcKfzUScV
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-7=-54, 7-9=-54, 16-19=-20
Concentrated Loads (lb)
Vert: 3=-147(B) 7=-147(B) 15=-452(B) 13=-40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=-90(B) 28=-90(B) 30=-90(B) 31=-90(B)
32=-90(B) 33=-40(B) 34=-40(B) 35=-40(B) 36=-40(B) 37=-40(B) 38=-40(B) 39=-40(B) 40=-40(B) 41=-40(B)
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. f0/03�2015 BEFORE.USE. �'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see • ANSI/TPH Qualify Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information. available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T16686500
M11392
J1
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:55 2019 Page 1 .
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-MPOeJC1 vfRQQXufvEWOR?UrEfds3pKrngTz9t6zUScU
-1-0-0 1-0-0
1-0-0 1-0-0
3x4 =
Scale = 1:6.1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) -0.00
5 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical
Max Horz 2=48(LC 12)
Max Uplift 3=-4(LC 9), 2=-140(LC 12)
Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
Walter P. Finn PE N6.22638',
MiTek USA; Inc. FL 6rf 6634.
6904 Parke East Blvd. Tampa FL 331i10
Date::
April 3,2019
A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage,delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute,. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City .
Ply
THE WINDSOR
T16686501
M11392
J3
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:55 2019 Page 1
ID:_kfiGCA6bx7jj2Syl HDXFw7ye3KX-MPOeJC1 vfRQQXufvE WOR?UrEYdgQpKmgTx9t6zUScU
-1-0-0 3-0-0
• 1-0-0 3-0-0
Scale = 1:9.4
3x4 =
3-0-0
3-0-0
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
0.01
4-7
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.19
Vert(CT)
-0.01
4-7
>999
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 11 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical
Max Horz 2=85(LC 12)
Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12)
Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-0-0 to 2-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift at joint 4.
Walter P. Finn FENo.221l
MiTek USA; Inc. Ft. 6erE6634
6904 Parka East Blvd. Tampa FL 33610
Date::
April 3,2019
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. '`
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T16686502
M11392
J5
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
1-0-0
3x4 =
8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:56 2019 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-rbal WY2XQIYH92E6oEXgYhOGnO2hYn5wv7hiPYzUScT
5-0-0
5-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.73
Vert(LL)
0.07
4-7
>863
240
TCDL 7.0
Lumber DOL
1.25
BC 0.70
Vert(CT)
-0.06
4-7
>964
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP ND.3
REACTIONS. (lb/size) 3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical
Max Horz 2=123(LC 12)
Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12)
Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:12.7
PLATES GRIP
MT20 244/190
Weight: 17 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 lb uplift at joint 4.
Walter P. Finn PE 146.22638',
MiTek USA, Inc. FL Cerf 6634
6904 Parke East Blvd. Tampa FL 33610'
Date:,
April 3,2019
,&WARNING - Vedty design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11711-7473 rev. la (0312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MiTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686503
M11392
J7
MONO TRUSS
24
1
•
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
-1-0-0
3x4 =
8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:57 2019 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-Jo8Pku29B3h8nCplLx2v5vxV WQSnHEL48nQGx_zUScS
Scale: 3/4"=1'
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL) 0.17 4-7 >494 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.39
Vert(CT) -0.19 4-7 >447 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=165/Mechanical, 2=315/0-8-0, 4=88/Mechanical
Max Horz 2=161(LC 12)
Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC 12)
Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) "'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at
joint 2 and 12 lb uplift at joint 4.
Walter P. Finn FE No.22839',
MiTek USA, Inc. FL 6rf6634
6904 Parke East Blvd. Tampa FL 33610
Date:.
April 3,2019
,& WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 101=2015 BEFORE USE. •
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage,delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T16686504
M11392
KJ7
MONO TRUSS
4
1
'
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Dec 6 2018 MiTek Industries, Inc. Wed Apr 3 10:18:57 2019 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-Jo8Pku29B3h8nCplLx2v5vxZmQVpHBb48nQGx zUScS
-1-5-0 6-8-12 9-10-1
1-5-0 6-8-12 3-1-5
3x4 =
5
3x4 =
Scale = 1:20.6
6-8-12
9-10-1
6-8-12
3-1-5
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/defi Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.20
Vert(LL) -0.04
7-10 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.26
Vert(CT) -0.08
7-10 >999 180
BCLL 0.0
Rep Stress Incr NO
WB 0.24
Horz(CT) 0.01
5 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 38 Ito FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=127/Mechanical, 2=379/0-11-5, 5=461/Mechanical
Max Horz 2=192(LC 8)
Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=-238(LC 8)
Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-838/366
BOT CHORD 2-7=-487/798, 84=487/798
WEBS 3-7=0/307, 3-6=-920/561
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at
joint 2 and 238 lb uplift at joint 5.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-4=7133(F=-39, B=-39), 8=0(F=10, B=10)•to-5=-4g(F=-15, B=-15)
Walter P. Finn PE No.22639.
MiTek USA,Inc. FL 6rf66U
6964 Parke East Blvd. Tampa FL 33610
Date:
April 3,2019
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE
'
Design valid for use only with MiTek®connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
` a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance. regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPl1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Symbols
Numbering System
General Safety Notes
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
4 offsets are indicated.
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
Failure to Follow Could Cause Property
Damage or Personal Injury
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
1 2 3
1. Additional stability bracing for truss system, e.g.
and fully embed teeth.
TOP CHORDS
diagonal orX-bracing, is always required. See BCSI.
0_�
c1-2 c2-3
2. Truss bracing must be designed by an engineer. For
WEBS �a 4 4
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
T
p
O
bracing should be considere d.
,
V3 ��� a� N O
3. Never exceed the design loading shown and never
0 U
stack materials on inadequately braced trusses.
00 a0
4. Provide copies of this truss design to the building
For 4 x 2 orientation, locate
c7-8 c6a cs s 0
BOTTOM CHORDS
designer, erection supervisor, property owner and
plates 0- yid' from outside
all other interested parties.
edge of truss.
8 7 6 5
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
This symbol indicates the
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
joint and embed fully. Knots and wane at joint
required direction of slots in
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
locations are regulated by ANSI/TPI 1.
connector plates.
THE LEFT.
7. Design assumes trusses will be suitably protected from
.
Plate location details available in MiTek 20/20
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
the environment in accord with ANSI/TPI 1.
software or upon request.
NUMBERS/LETTERS.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
^ PLATE SIZE
PRODUCT CODE APPROVALS
9. Unless expressly noted, this design is not applicable for
ICC-ES Reports:
use with fire retardant, preservative treated, or green lumber.
The first dimension is the plate
10. Camber is a non-structural consideration and is the
4 x 4 width measured perpendicular
ESR-1311, ESR-1352, ESR1988
responsibility of truss fabricator. General practice is to
' to slots. Second dimension is
ER-3907, ESR-2362, ESR-1397, ESR-3282
camber for dead load deflection.
the length parallel to slots.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
LATERAL BRACING LOCATION
12. Lumber used shall be of the species and size, and
Indicated by symbol shown and/or
by text in the bracing section of the
Trusses are designed for wind loads in the plane of the
truss unless Otherwise shown.
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
output. Use T or I bracing
spacing indicated on design.
if indicated.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
g y
14. Bottom chords require lateral bracing at h r spacing,
or less, if no ceiling is installed, unless otherwise noted.
BEARING
established by others.
15. Connections not shown are the responsibility of others.
Indicates location where bearings
16. Do not cut or alter truss member or plate without prior
(supports) occur. Icons vary but
© 2012 MiTek® All Rights Reserved
approval of an engineer.
reaction section indicates joint
number where bearings occur.
17. Install and load vertically unless indicated otherwise.
Min size shown is for crushing only.
6-a
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
Industry Standards:
W1
project engineer before use.
ANSI/TPI1: National Design Specification for Metal
19. Review all portions of this design (front, back, words
Plate Connected Wood Truss Construction.
and pictures) before use. Reviewing pictures alone
DSB-89: Design Standard for Bracing.
a
is not sufficient.
BCSI: Buildin Com onent Safe Information,
9 P tY
MiTek
20. Desi n assumes manufacture in accordance with
g
Guide to Good Practice for Handling,
ANSI/TPI 1 Quality Criteria.
Installing & Bracing of Metal Plate
' Connected Wood Trusses.
MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015