Loading...
HomeMy WebLinkAboutPartial Roof PlanPARTIAL FRONT ELEVATION SCALE %" PARTIAL ROOF PLAN SCALE %" M Planning & Development Services Department COUNTY' Building & Code Regulations Division I 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida e QJT Code Sixth Edition with a0 ✓ -Supplements using ASCE 7-10 2. Structure Designed as (check one): ✓ Enclosed --Partially Enclosed Open 3. Risk Category:_1 _ .- 11 —III IV Exposure Category: B C V"' D 4. Design Wind Velocity--'-/.. 7z:2_mph-4LZ_ASD LRFD End Zone Width: Z4 ft 5. Mean Roof Height , fQ ft Roof Pitch:__ Z _:12 Parapet-_-- ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1*s—Zone 2: /9 ' Zone 3: !q - one 4:--z--7 Zone 5: 'r{Sl— Garage: 7. Design Loads: Floor:' PSF Roof/Dead: 1Z PSF Roof/Live: 30 Balcony: — PSF Dock: PSF Deck: PSF Stairs: PSF Fence:_" PSF Railings: -- PSF 8. Were Shear Walls Considered For Structure? ✓Yes ,Nut Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? L! Yes— Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: e <400 PSF Soil Test Reports Submitted?/ o Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide aidequate resistance to the design forces specified: PRODUCT APPROVAL ft-- OpaWnq Desiso Proclttct Rotod uIltdoatum I1lO&I "Umther (fit Approv*1 (}j"` Gt"s W. ...... �. Moth Ad of Attachment ........._. ^ f�dcYSc?1 ``a`,t;tlttln11111j�rf�'/', G �UTC 7o878 o " ; 9�p. �� RHO. • ��� . """ISS10 N A� �``��nnuntn��t REVIE-WED FOR CODE C;0P01PL1ANC",7' ill w 7- CIE 76(7h 61 . GENERAL NOTES: 1. THE CONTRACTOR REMOVED A SECTION OF THE TILE ROOF TO REPAIR A LEAK. 2. THE PLYWOOD SHEATHING TO BE RE -NAILED WITH 8d RING SHANK NAILS. 3. NEW SELF ADHERING UNDERLAYMENT TO BE INSTALLED. 4. "L" FLASHING AT WALL TO BE MODIFIED BITUMEN 12" UNDER THE UNDERLAYMENT AND 24" UP THE WALL TO A TERMINATION BAR ATTACHED TO THE WALL. 5. NEW ENTEGRA CEMENT TILE TO BE INSTALLED WITH (2) SMALL-AH-160 PADDYS. 6. THESE PLANS & SPECIFICATIONS COMPLY WITH THE 20-17 FBC (6t" EDITION) & ASCE 7- 10. 7. OWNER/CONTRACTOR TO VERIFY ALL DIMENSIONS AND STUCTURAL CONDITIONS.AS SHOWN ON THE PLANS. ANY DISCREPENCY BETWEEN THE PLANS AND THE ACTUAL EXISTING CONDITIONS SHOULD BE REPORTED TO THE ENGINEER IMMEDIATELY. Design by: RICHARD A. JEMISON P.O. Box 5616 Ft. Pierce, Fl. 34954 (772) 21.5-5623 4 BENCHMARK ENGINEERING OF THE TREASURE COAST 806 DELAWARE AVE. FT. PIERCE, FL. 34950 (772) 772-267-1399 06/01 /20 SEAL RE -ROOF A SECTION OF ROOF SHEET FONTENELE PLAZA BOwDOT.V 2303 N US HWY 1 P.E. #70878 FT. PIERCE, FLORIDA OF I__.__� li PARTIAL FRONT ELEVATION SCALE %" 1� PARTIAL ROOF PLAN SCALE %" M Planning & Development Services Department Building FA Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida_ s? 47/7 -Code Sixth Edition with 20 ✓/ Supplements using ASCE 7-10 2. Structure Designed as (check one): ✓ Enclosed Partially Enclosed Open 3. Risk Category: 1_.— ,11 HI IV Exposure Category: B C �D 4. Design Wind VelocityT 0 mph_,j -? ASD —LRFD End Zone Width: la ft 5, Mean Roof Height/40 ft Roof Pitch:_, Z :12 Parapet: -- ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1f/Q'Zone 2: f9 ' f Zone 3: �q -tsar Lane 4: `fit Zone S:Garage: 7. Design Loads: Floor: PSF Roof/Dead:_ %z PSF Roof/Live: 30 Balcony: -- PSF Dock: — PSF Deck: PSF Stairs:^ PSF Fence: PSF Railings: ^ " PSF 8. Were Shear Walls Considered For Structure? ✓"�fes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? i/ Yes____ __Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: J ,0 Q PSF Soil Test Reports Submitted?/J1ti Yes DES16N PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my krowiedge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Opardag Ovaign Produact Rated Martrhrait"W NO" Pro*mi Approval Glass Method of Attachrnsnt Arsrifs I L �;520 < —S ,52`S --150 R,EVIEWED FOR 3 0( Y GENERAL NOTES: 1. THE CONTRACTOR REMOVED A SECTION OF THE TILE ROOF TO REPAIR A LEAK. 2. THE PLYWOOD SHEATHING TO BE RE -NAILED WITH 8d RING SHANK NAILS. 3. NEW SELF ADHERING UNDERLAYMENT TO BE INSTALLED. 4. "L" FLASHING AT WALL TO BE MODIFIED BITUMEN 12" UNDER THE UNDERLAYMENT AND 24" UP THE WALL TO A TERMINATION BAR ATTACHED TO THE WALL. 5. NEW ENTEGRA CEMENT TILE TO BE INSTALLED WITH (2) SMALL AH-160 PADDYS. 6. THESE PLANS & SPECIFICATIONS COMPLY WITH THE 2017 FBC (6th EDITION) & ASCE 7- 10. 7. OWNER/CONTRACTOR TO VERIFY ALL DIMENSIONS AND STUCTURAL CONDITIONS.AS SHOWN ON THE PLANS. ANY DISCREPENCY BETWEEN THE PLANS AND THE ACTUAL EXISTING CONDITIONS SHOULD BE REPORTED TO THE ENGINEER IMMEDIATELY. Desin by: RICHARD A. JEMISON P.O. Box 5616 Ft. Pierce, Fl. 34954 UTC�o,(772) 215-5623 CD 1111111!1® 4 BENCHMARK ENGINEERING OF THE TREASURE COAST 806 DELAWARE AVE. FT. PIERCE, FL. 34950 (772) 772-267-1399 06101 /20 SEAL RE -ROOF A SECTION OF ROOF SHEET FONTENELE PLAZA BOWDOIN 2303 N US HWY 1 P.I. #70878 FT. PIERCE, FLORIDA OF 1 j