Loading...
HomeMy WebLinkAboutProduct Approval Roofing Tiles1'- dFW. ° �i `,""'' �9 r D Q a ���� r .� �'- tkal .�', n';. 'y �. "S;Y`"z'•*.h '-^°+.' -- _ -�+.ft'!M BCIS Home � Log In 1 User Registration ( Hot Topics � Submit Surcharge 1 Stats &Facts I Publications t Contact Us I BCIS Si[e Map I Links 1 Search Fonda Product Approval f{sI USER: Public User Product Approval Menu > Application Detail FL # FL7804-R10 Application Type Revision Code Version 2017 REVIEWED. FOR Application Status Approved CODE C OCY91f"E IANL " Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email- , ST. llsUCIE COUNTY BOC Entegra Roof Tile, LLC 1289 NE'9th Avenue Okeechobee, FL 34972 �602 515-6933 thomas.jem melt@ boral. co m Thomas Jemmett tho mas.jemmett@ boral. co m FILE %;U r Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 11/03/2020 Validated By John W. Knezevich, PE , Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL7804 R10_C II 2016 01 COI Nieminen.pdf Standard Year ASTM C1492 2003 FRSA/TRI April 2012 2012 SSTD 11 1997 TAS 100 1995 TAS 101 1995 TAS 102 1995 TAS 102(A) 1995 https://www.floridabuilding.org/pr/pr_app_dti-aspx?param=wGEV...1%2bAMgsl79%2bkb9MWULRpAyR%2fQOg3lx7gHM6LOA%3d%3d 6/6/20, 7:13 AM Page 1 of 2 43 TAS 112 T Nail Holes —1--� 7 Estate "S" 4.3 TAS 112 Type 2a (non -interlocking, high pr 17" 10" Galena Spanish "S" Hacienda GALENA SPANISH "S" and REGAL ' Exterior Research and Design, I.I.C. Certificate ofAutharization #9503 61" EDITION (2017) FBC HVHZ EVALUATION Entegra Roof Tiles .. Regal Evaluation Report E39310.11.11-1-R4 FL7804-R10 Revision 4: 10/17/2017 Page 4 of 8 VTRINI-Ty ERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in, any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluatiori;'refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services'of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix `A'. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida -Statewide" Product Approval . or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. TABLE 1 AERODYNAMIC MULTIPLIERS�FT }; Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Horizon Flat 0.305 0.330 Bella High "S" 0.349 0.378 Estate "S" 0.267 0.289 Hacienda 0.267 0.289 Galena Spanish "S" N/A 0.235 Rega I 0.287 0.311 TABLE 2: `RESTORING MOMENT DUE TO GRAVITY- M��(FT LBF)-;, Tile Roof Slope (0) 2:12<0<3:12 3:12<0<4:12 4:12<0<5:12 5:12<0<6:12 6:12<0<7:12 0>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 ' 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High"S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 1 6.13 Estate "S" 6.14 6.84 5.91 6.74 5.82 6.64 1 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61 Exterior Research and Design, LLC.. Certificate ofAuthorization #9503 6"' EDITION (2017). FBC HVHZ EVALUATION Entegra Roof Tiles Evaluation Report E39310.11.11-1-R4 FL7804-R10 Revision 4:10/17/2017 Page 5 of 8 TABLE 3A ATTACHMENT RESISTANCE EXPRESSED AS A MOMENL- MF fiF� LBFj ' ' _ " ; ; MECHANICALLY ATTACHED SYSTEMS , ' Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Size Shank Clip Nail One (1) lod Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) 10d Smooth or.Screw Eave 19.0 19.0 22.1 Nail One (1) lod Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two (2) lod Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two (2) lod Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) 10d Ring. N/A 30.9 38.1 17.2 Nail" Two (2)' 10d' Ring' N/A 50.31 65.51 48.3' Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) #8 N/A N/A 51.7 51.7 24.4 ' Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile. Nail One (1)2 10d Smooth or Screw N/A 8.82 11.82 4.12 Nail Two (2) 10d Smooth or Screw N/A 16.4 21.9 7.1 Nail one (1)' 10d Smooth or Screw Eave 19.02 19.02 22.12 Nail One j0d Smooth or Screw Field 24.32 24.32 24.22 Nail Two (2) 10d Smooth or screw Eave 31.9 31.9 32.2 "S" Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Estate or Hacienda Nail Two (2) 10d Ring N/A 27.8 37.4 28.8 Nail' Two (2)' 10d' Ring' N/A 43.0' 67.5' 50.91 Screw one #8 N/A N/A 25.82 25.82 22.92 Screw Two (2) #8 N/A N/A 47.1 47.1 49.1 1 Installation with a 4-inch tile headlap and fasteners located min. 2'/2-inch from head of tile. 2 For one (1)'fastener installations, utilize hole that is approximately 4%-inch from the interlocking edge. Nail One (1) SOd Smooth or Screw N/A 5.1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One (1) lod Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) lod Smooth or Screw Eave 29.3 29.3 24.0 Nail Two (2) lod Smooth or Screw Field 27.6 27.6 38.6 Bella High "S", Galena Spanish "S" or Regal Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Nail Two (2) 10d Ring N/A 28.6 41.2 19.4 Nail' Two (2)' iod' Ring' N/A 33.11 48.1' 50.9' Screw One (1) #8 N/A N/A 20.7 20.7 18.1 Screw Two (2) #8 N/A N/A 43.2 43.2 29.8 'Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile. Exterior Research and Design, I.I.C. Certificate of Authorization #9503 6T"EDITION (2017) FBC HVHZ EVALUATION Entegra Roof Tiles Evaluation Report E39310.11.11-1-R4 FL7804-R10 Revision 4: 10/17/2017 Page 6 of 8 ,A- F)0_ -J TRINITY (ERb TABLE:. ATTACHIvi T*sISTANCE EXPRE55EU A5 A'MOMENT,- MF,(FT-LBF) " MORTAR AND 14DHESIVE-SET SYSTEMS " Note from Entegrb Roof Tile, LL,C : -The performance Vato, listed in Table 4t are based on.: the respective adhesive manufacturers'.«test ". reports _and Miami Dade,NOAs. Entegra Roof Tle Ll � relies upon ,the adhesive manufacturers to provide these" values for`our inclusion in' this `FBC"NVHZ' Evaluation" -Report � -Pease consult:�the individual adhesive_ manufacturer for information on product approvals, i, f , f. , g wind load and overturning: moment.perforinance..,., Lmitations, revisions or other in ormation . or deterninin ' Tile Adhesive Tile Product Product Approval Placement Mf (ft-lbf) `ILE BONDTM" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat, "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Plantation Flat or Horizon „ ® Polyset AH-160 by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 43 add Independent medium paddy, g) ^30 ( 51 Independent (large paddy, —45 g) 92 "TILE BOND'" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 42 "S" "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate or Hacienda "polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent(2-paddy) 50 Independent (medium paddy, ^30 g) 37 Independent (large paddy, —54 g) 61 Mortar Various Per RAS 120 21 `ILE BONDTM"'by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 48 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 52 Bella High "'S", "polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 Galena Spanish "S" or Regal "polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 30 Independent (medium paddy, —30 g) 49 Independent (large paddy, —63 g) 94 Mortar Various Per RAS 120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or NT ORR Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R4 Certificate ojAuthorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 7 of 8 i Q0TRINITY ER® and/or a S,O n 11111111111111111p, Labeling: Horizon Flat, Hacienda, Regal 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority -Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING'PLANTS: ant. - Profiles - Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, I.I.C. Evaluation Report E39330.31.11-1-R4 Certificate ofAuthorization#9503 6T"EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:.10/17/2017 Page 8 of 8