HomeMy WebLinkAboutProduct Approval Roofing Tiles1'-
dFW.
° �i `,""'' �9 r D Q a ���� r .� �'- tkal .�', n';. 'y �. "S;Y`"z'•*.h '-^°+.' -- _ -�+.ft'!M
BCIS Home � Log In 1 User Registration ( Hot Topics � Submit Surcharge 1 Stats &Facts I Publications t Contact Us I BCIS Si[e Map I Links 1 Search
Fonda
Product Approval
f{sI USER: Public User
Product Approval Menu > Application Detail
FL # FL7804-R10
Application Type Revision Code Version 2017 REVIEWED.
FOR
Application Status Approved CODE C OCY91f"E IANL "
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email- ,
ST. llsUCIE COUNTY
BOC
Entegra Roof Tile, LLC
1289 NE'9th Avenue
Okeechobee, FL 34972
�602 515-6933
thomas.jem melt@ boral. co m
Thomas Jemmett
tho mas.jemmett@ boral. co m
FILE %;U r
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nieminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date
11/03/2020
Validated By
John W. Knezevich, PE ,
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL7804 R10_C II 2016 01 COI Nieminen.pdf
Standard
Year
ASTM C1492
2003
FRSA/TRI April 2012
2012
SSTD 11
1997
TAS 100
1995
TAS 101
1995
TAS 102
1995
TAS 102(A)
1995
https://www.floridabuilding.org/pr/pr_app_dti-aspx?param=wGEV...1%2bAMgsl79%2bkb9MWULRpAyR%2fQOg3lx7gHM6LOA%3d%3d 6/6/20, 7:13 AM
Page 1 of 2
43 TAS 112 T
Nail Holes —1--�
7
Estate "S"
4.3 TAS 112 Type 2a (non -interlocking, high pr
17"
10"
Galena Spanish "S"
Hacienda
GALENA SPANISH "S" and REGAL '
Exterior Research and Design, I.I.C.
Certificate ofAutharization #9503 61" EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles ..
Regal
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4: 10/17/2017
Page 4 of 8
VTRINI-Ty ERD
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in, any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluatiori;'refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services'of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix `A'.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida -Statewide" Product Approval . or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
TABLE 1 AERODYNAMIC MULTIPLIERS�FT };
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
0.189
0.205
Plantation Flat
0.267
0.289
Horizon Flat
0.305
0.330
Bella High "S"
0.349
0.378
Estate "S"
0.267
0.289
Hacienda
0.267
0.289
Galena Spanish "S"
N/A
0.235
Rega I
0.287
0.311
TABLE 2: `RESTORING MOMENT DUE TO GRAVITY- M��(FT LBF)-;,
Tile
Roof Slope
(0)
2:12<0<3:12
3:12<0<4:12
4:12<0<5:12
5:12<0<6:12
6:12<0<7:12
0>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09 '
6.27
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
7.95
7.09
7.76
6.89
7.55
Bella High"S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
1 6.13
Estate "S"
6.14
6.84
5.91
6.74
5.82
6.64
1 5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish "S"
N/A
6.20
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
7.65
8.20
7.49
8.03
7.30
7.83
7.10
7.61
Exterior Research and Design, LLC..
Certificate ofAuthorization #9503 6"' EDITION (2017). FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4:10/17/2017
Page 5 of 8
TABLE 3A ATTACHMENT RESISTANCE EXPRESSED AS A MOMENL- MF fiF� LBFj '
' _ " ; ; MECHANICALLY ATTACHED SYSTEMS , '
Tile
Fastener
Direct -Deck
(min.15/32"
plywood)
Direct -Deck
(min.19/32"
plywood)
Battens
Type
#
Size
Shank
Clip
Nail
One (1)
lod
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
10d
Smooth or.Screw
Eave
19.0
19.0
22.1
Nail
One (1)
lod
Smooth or Screw
Field
24.3
24.3
24.2
Bermuda Flat,
Nail
Two (2)
lod
Smooth or Screw
Eave
31.9
31.9
32.2
Plantation Flat or
Nail
Two (2)
lod
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
10d
Ring.
N/A
30.9
38.1
17.2
Nail"
Two (2)'
10d'
Ring'
N/A
50.31
65.51
48.3'
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
Screw
Two (2)
#8
N/A
N/A
51.7
51.7
24.4
' Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile.
Nail
One (1)2
10d
Smooth or Screw
N/A
8.82
11.82
4.12
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
one (1)'
10d
Smooth or Screw
Eave
19.02
19.02
22.12
Nail
One
j0d
Smooth or Screw
Field
24.32
24.32
24.22
Nail
Two (2)
10d
Smooth or screw
Eave
31.9
31.9
32.2
"S"
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Estate or Hacienda
Nail
Two (2)
10d
Ring
N/A
27.8
37.4
28.8
Nail'
Two (2)'
10d'
Ring'
N/A
43.0'
67.5'
50.91
Screw
one
#8
N/A
N/A
25.82
25.82
22.92
Screw
Two (2)
#8
N/A
N/A
47.1
47.1
49.1
1 Installation with a 4-inch tile headlap and fasteners located min. 2'/2-inch from head of tile.
2 For one (1)'fastener installations, utilize hole that is approximately 4%-inch from the interlocking edge.
Nail
One (1)
SOd
Smooth or Screw
N/A
5.1
6.8
2.8
Nail
Two (2)
10d
Smooth or Screw
N/A
6.9
9.2
7.3
Nail
One (1)
lod
Smooth or Screw
Field
23.1
23.1
19.0
Nail
One (1)
lod
Smooth or Screw
Eave
29.3
29.3
24.0
Nail
Two (2)
lod
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "S", Galena
Spanish "S" or Regal
Nail
Two (2)
10d
Smooth or Screw
Eave
38.1
38.1
41.8
Nail
Two (2)
10d
Ring
N/A
28.6
41.2
19.4
Nail'
Two (2)'
iod'
Ring'
N/A
33.11
48.1'
50.9'
Screw
One (1)
#8
N/A
N/A
20.7
20.7
18.1
Screw
Two (2)
#8
N/A
N/A
43.2
43.2
29.8
'Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile.
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503 6T"EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4: 10/17/2017
Page 6 of 8
,A-
F)0_
-J TRINITY (ERb
TABLE:. ATTACHIvi T*sISTANCE EXPRE55EU A5 A'MOMENT,- MF,(FT-LBF) "
MORTAR AND 14DHESIVE-SET SYSTEMS "
Note from Entegrb Roof Tile, LL,C : -The performance Vato, listed in Table 4t are based on.: the respective adhesive manufacturers'.«test
". reports _and Miami Dade,NOAs. Entegra Roof Tle Ll � relies upon ,the adhesive manufacturers to provide these" values for`our inclusion
in' this `FBC"NVHZ' Evaluation" -Report � -Pease consult:�the individual adhesive_ manufacturer for information on product approvals,
i, f , f. , g wind load and overturning: moment.perforinance..,.,
Lmitations, revisions or other in ormation . or deterninin '
Tile Adhesive
Tile
Product
Product Approval
Placement
Mf (ft-lbf)
`ILE BONDTM" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Flat,
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Plantation
Flat or
Horizon
„ ®
Polyset AH-160 by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
43
add
Independent medium paddy, g) ^30
(
51
Independent (large paddy, —45 g)
92
"TILE BOND'" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
44
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
"S"
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate or
Hacienda
"polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent(2-paddy)
50
Independent (medium paddy, ^30 g)
37
Independent (large paddy, —54 g)
61
Mortar
Various
Per RAS 120
21
`ILE BONDTM"'by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
48
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella High
"'S",
"polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
Galena
Spanish "S"
or Regal
"polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
30
Independent (medium paddy, —30 g)
49
Independent (large paddy, —63 g)
94
Mortar
Various
Per RAS 120
25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
NT ORR
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R4
Certificate ojAuthorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 7 of 8
i Q0TRINITY ER®
and/or
a S,O
n 11111111111111111p,
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority -Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING'PLANTS:
ant. -
Profiles -
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, I.I.C. Evaluation Report E39330.31.11-1-R4
Certificate ofAuthorization#9503 6T"EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:.10/17/2017
Page 8 of 8