HomeMy WebLinkAboutProgress Inspection Report 21, 20 & 23 KEYSTONE
Phone: '121-454-7300
ENGINEERING
CONSULTING, INC.
Progress Inspection Report #21
Permit #SLC 2102-0371
Project Name: Barclay Beach Club Progress Report thru 10-8-21
Project Address: 2800 SR-Al A, Hutchinson Island Inspection Visits: 10-8-21
Prime Contractor: Blue Coast Construction
Superintendent: Rafael Rodriguez
Activities in-progress: 06 and 07 stack textures and paint, 05 stack grinding, shutter track
reinstallations, and new marks for repair
INSPECTOR'S REPORT
Keystone Engineering visited the site on 10-8-21 and had several conversations with the
construction team by telephone throughout the week.
This week the construction crew completed the final knockdown textures and painting except for
the final floor coatings on the 06 and 07 stacks. Handrail removal was completed on the
05 stack and shutter track reinstallations on the ceilings are in progress. After removing
the handrails new spalls were discovered along the edge where the core mounted
handrail posts existed. Keystone Engineering re-inspected the balconies and marked
new spalls for repairs. Workers are grinding the floors and new excavations will begin to
address the new spalling.
.,
ri
s• No. 50068 ,
STATE OF tZr
4
?,�.%%1.4 O R►D.P'
SS'O N A L•S*6�����````
,= 1%
• i
'e
View of a new edge spall marked for repair on the Unit 605 balcony
View of an additional new spall marked for repair on the Unit 605 balcony
f.
View of corroded rebar exposed in the edge of the Unit 405 balcony
5
t �t
s .It,
OVA
View of new spalling marked for repair on the Unit 205 balcony
,
View of a new spall marked for repair on the Unit 205 balcony
South25 BreN,ard
KEYSTONECocoa B •.
• • •
= 1 ENGINEERING & Fax: 321-459-2888
CONSTILTMG, INC.
Progress Inspection Report #22
Permit #SLC 2102-0371
Project Name: Barclay Beach Club Progress Report thru 10-15-21
Project Address: 2800 SR-A1A, Hutchinson Island Inspection Visits: 10-15-21
Prime Contractor: Blue Coast Construction
Superintendent: Rafael Rodriguez
Activities in-progress: 06 and 07 stack painting and shutter track reinstallations, 05 stack new
excavations, 04 stack cast backs and stucco applications
INSPECTOR'S REPORT
Keystone Engineering visited the site on 10-15-21 and had several conversations with the
construction team by telephone throughout the week.
This week new excavations were completed on the 05 stack to address the new concrete
spalling found on the edge of the balconies after the handrails were removed. A pre-pour
inspection was completed on Friday, steel prep and form installations are in progress to
prep for cast backs.
Painting is finishing up on the 06 and 07 stacks, where the construction crew applied the final
floor coatings on the balconies. Floor shutter tracks are being reinstalled on the 06 stack,
reinstallations will soon begin on the 07 stack as well. Workers cast back the new edge
repairs on the east side of the 04 stack, where stucco applications are in progress.
j�4/
22
..,._...,
�• No. 5�0068 i
S'i' �E OF J.
't '
, w�
o •..•4 O 11.1• .: �s
a
Y=• -
w
i T 2
L
RSFS�I•a + �: � �
Ar. US
1. 'X r3Y.riZT..
View of the final floor coatings applied on the Unit 407 balcony
AQ
n,•,..1 — Q,La
�t,'•r S-{.. -te�',Co�: `•F=,
7
ti � ��:'�- ti;� ''�h�-y >> tw'� q��.'�Sri-•, �.�'��. a � k.�'7��,'i_ �-w? �'�'�' :�; �T"'
�'� eS X.S.*r �7 p\+ 7^`� 'S 4� ��??� ..�f: .A���i.�li�.t�t,, t +} �a�Q� �• , 4 t'�, ti Z �r.
'� � "' .. +�P�f.'��1 yi� d, � .�,S�.�1+� \�+W*•+.�"�;��� �� � �3i��7}�' �
`"r,ra 4.j�� +��,{'-!� 7}��f�' ��� i" 4��}� � `'1`�Z +�1�e -},,k f','�,�' ��`� � `�1 �•',�yi
"k! �*•F<,{,�i ';r-:�i'+y�•+ �,.1' �1 '��'�j1,�t'�'tR,,ti`� +��ti: t F rtitir. -S� +� n� Ta���.�:j.�#Ly''2 „�1r�.
%,+tp?, '�'�; t { '�M'�� �tt�.•
.,.i ,+•*,.:. i- �,,.� ,�...a.:'7\ � .? `,.,.• �s�,
View of the final floor coatings applied on the Unit 307 balcony
{
k
�r�, } ��[ t r t s `p•x ` �'fie��!"�
1
View of the final floor coatings applied on the Unit 207 balcony
C
i
N
View of the stucco applications in progress for the new edge repairs on the 04 stack
View of a new edge repair in progress
.11
a+f
View of a new edge repair in progress on the Unit
Ii
•alti� -
00
K �' a •,� t
yr
1�
Y'ti • w7t. lp
OP
Pi.
1
�jr k
View of a new edge repair in of a new edge repair in progress on the Unit 205 balcony the Unit 205 balcony
t—
,
South25 Brevard
• • •
ENGINEERING &
CONSULTING, INC.
KEYSTONECocoa Beach, FL 32931 Fax: 321-459-2888
Progress Inspection Report #23
Permit #SLC 2102-0371
Project Name: Barclay Beach Club Progress Report thru 10-22-21
Project Address: 2800 SR-Al A, Hutchinson Island Inspection Visits: 10-21-21
Prime Contractor: Blue Coast Construction
Superintendent: Rafael Rodriguez
Activities in-progress: 07 stack shutter reinstallations, 06/07 stack floor coatings, 04 stack
waterproofing, and 08 stack mobilization
INSPECTOR'S REPORT
Keystone Engineering visited the site on 10-15-21 and had several conversations with the
construction team by telephone throughout the week.
This week the construction crew finished applying the 2nd layer of floor coatings on the 06 and
07 balcony stacks. Waterproofing applications are in progress on the 04 stack, and
workers are cleaning the 05 stack balconies to prep for waterproofing. Floor shutter track
reinstallations are also in progress for the 07 stack.
The crew installed a swing stage over the 08 stack, initial marks for repair were completed on
Thursday. Floor coating removal is in progress, after coatings are removed balconies will
be re-inspected and marked. Next week the crew will install a swing stage on the 01
stack where marks for repair will continue.
�d ' �GENSF ;'••�
•
I
No. 0 �r
q ST&TE of r
OP.
a
'�n���i III IIIMON
s
g
View of an edge spall marked for repair on the Penthouse 6 balconAt
3 C
Y
r fin
1�C�+�r+ 1f ,��as , � +y��?p r'"St • r r+}F, t K i+'3;'E r � �
,a
� J^
r♦� .,
View of a surface spall marked for repair on the Unit 1008 balcony
1
View of marks for repair on the Unit 908 balcony
View of corroded reinforcement exposed on the edge of the Unit 708 ceiling
ti
4 •-yam _ __.x..--.-.. e _ '�`--.
or
View a spall marked for repair on the edge of the Unit 708 ceiling
i
f.
II,
�1.
View of a surface spall marked for repair on the Unit 608 balcony
f 1.
View of marks for repair on the Unit 408 balcony
�\r
View of marks for repair on the Unit 208 balcony
-
nunu�unnuu
figmt �
olfr - - -
View of the swing stage installed above the 08 stack