Loading...
HomeMy WebLinkAboutProduct Approval -Mullion BUILDING DROPS REI&B IR 398E Dania Beach Suite 3 8 A Perfect Solution in Every Drop COD E COMPLIANCE Dania Beach, FL 84 8004 PH Certificate of Authorization:29578 T. LU IE COUNTY 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of Ply Gem Windows Pro Series Classic Vertical Mullion (Impact) for Florida Product Approval FL# FL15262 ,4 Report No. 5107 Current Florida Building Code Method: 2 — B (Engineering Evaluation) Category: Windows Sub — Category: Mullions Product: Pro Series Classic Vertical Mullion (Impact) Material: 1010 Cold Rolled Steel Prepared for: Ply Gem Windows 433 N. Main St. P.O. Box 559 Rocky Mount, VA 26415 Prepared by: ; ���.�\• : -p O , Hermes Norero, P.E. 7 Florida Professional Engineer#73778 = * •• Date: 09/14/2017 = T T •• u = 441 Contents: -ice �S•• �jN�`�`� Evaluation Report Pages 1—4 ��i, �NAL 10*-IN Digitally signed by Hermes F.Norero,P.E. Herfnes�1��0, P.E. Reason:I am approving this document Florida No. 73778 Date:2017.09.28 09:56:11 -04'00' FL# BUILDING DROPS Date F 9/14/1 Date: 09/14/17 AL A Perfect Solution in Every Drop Report No: 5107 Certificate of Authorization:29578 Manufacturer: Ply Gem Windows Product Category: Windows Product Sub-Category: Mullions Compliance Method: State Product Approval Method (2)(b) Product Name: Pro Series Classic Vertical Mullion (Impact) Scope: This is a Product Evaluation Report issued by Hermes Norero, P.E. (FL#73778)for Ply Gem Windows based on Method 2b of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions PGW093,signed and sealed by Hermes Norero, P.E. (FL#73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering in Wind Zones 3 or less. 4. Site conditions that deviate from the details of PGW093 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions PGW093 for size and design pressure limitations. Hermes Norero, P.E. Florida No. 73778 Page 2 of 4 FL# 5262 BUILDING DROPS Date FL /14/1 Date: 09/14/17 {" A Perfect Solution in Every Drop Report No: 5107 Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: QUA1789). Code Section: The product described herein has been evaluated per: • Current FBC Section 1709.8 Referenced Data: 1. Quality Assurance National Accreditation and Management Institute (FBC Organization#: QUA1789) Hermes Norero, P.E. Florida No. 73778 Page 3 of 4 l FL# 15262 BUILDING DROPS Date F 9/14/1 Date: 09/14/17 A Perfect Solution in Every Drop Report No: 5107 Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates areas follows: Mull Clip Installations A. For two by(2X)wood frame substrate, use three (3)#8 Wood Screw type wood frame anchors at each clip of sufficient length to achieve minimum embedment of 1.50" into wood framing. B. For concrete or masonry substrate where wood bucking is not employed,or where wood bucking is employed, use three (3)3/16" ITW Tapcon type concrete screw anchors at each clip, of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel stud, use three (3)#8 SAE Grade 5 Self-Tapping Screw installation anchors at each clip of sufficient length to achieve 3 threads of minimum penetration beyond steel structure. Refer to Installation Instructions(PGW093)for anchor locations, installation methods, and more details of the installation requirements. Design Pressure: Refer to Installation Instructions PGW093,sheet 2 for design pressure tables and limitations of use. Hermes Norero, P.E. Florida No. 73778 Page 4 of 4 PLY GEM WINDOWS '433 N.MAIN ST.,PO BOX 559. ROCKY MOUNT.VA 24151 PRO SERIES CLASSIC VERTICAL MULLION GH 540-484-6348 FX W-464-6683 IMPACT J m m m Olt uF m Y} C, H>-O n GENERAL NOTES: •°'n .0 m P 1. THE PRODUCT SHOWN HEREIN I5 DESIGNED AND MANUFACTURED TO COMPLY U- V) O ci 2:LL WITH THE CURRENT FLORIDA BUILDING CODE. �',' �'Z �p<u <J <J < 2. MULLION INSTALLATION DETAILS APPLY TO DUAL 253273 HP MULL STEEL <CK coZ<m REINFORCEMENTS WITH EXTRUDED VINYL MULL STRIP WHEN USED TO MULL a N Z p 'd WINDOWS SIDE BY SIDE. o_ N W H<Z °•,` 0< s 3. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN w i CO W L3 3: WIND BORNE DEBRIS REGIONS ZONE 3 OR LESS.INDIVIDUAL UNITS MUST BE H � 1 m a IMPACT RATED. F- wt13 4. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN F 0 N WIND BORNE DEBRIS REGION ZONE 4. of o 5. USE 3/16"ITW TAPCON ANCHOR OF SUFFICIENT LENGTH TO ACHIEVE MINIMUM TABLE OF CONTENTS EMBEDMENT OF 1 1/4"INTO MASONRY OR CONCRETE. 3/16"ITW TAPCON MUST m "I HAVE A 2 1/2"MINIMUM EDGE DISTANCE FROM EDGE OF MASONRY OR CONCRETE. SHEET SHEET DESCRIPTION ,^ (SEE CHARTS d NOTES ON SHEET 2 FOR DESIGN PRE55URE AND ANCHOR NOTES). 1 INSTALLATION d GENERAL NOTES v I 6. USE#8 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE MINIMUM 2 ELEVATION,CHART,d NOTES O EMBEDMENT OF 1 1/2"INTO WOOD FRAMING.(SEE CHARTS d NOTES ON SHEET 2 3 VERTICAL d HORIZONTAL SECTIONS H FOR DESIGN PRESSURE AND ANCHOR NOTES). ,^ O < w 7. USE#8 TEK SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM 4 DETAILS H j N PENETRATION BEYOND STEEL STRUCTURE.(SEE CHARTS d NOTES ON SHEET 2 FOR DESIGN PRESSURE AND ANCHOR NOTES). w N Z m B. MASONRY,1X2 4 2X4 WOOD BUCKS TO BE DESIGNED AND ANCHORED TO PLu ROPERLY a 2 TRANSFER ALL LOADS TO STRUCTURE AND IS THE RESPONSIBILITY OF THE t" a ARCHITECT OR ENGINEER OF RECORD. v O 9. THIS MULLION I5 ONLY VALID WHEN USED IN CONJUNCTION WITH APPLICABLE LL 95 PLY GEM PRODUCTS. b 30. ALL WINDOWS USED WITH THIS MULLION SHALL BE QUALIFIED UNDER 1 In, % SEPARATE APPROVAL. ��� O JK 11. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS � �••'•••••••'�`" � HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE .• � b , FOLLOWING PROPERTIES: A.WOOD-MINIMUM SPECIFIC GRAVITY OF 0.55. UL H B. CONCRETE-MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. (n F.Q C.MA50NRY-STRENGTH CONFORMANCE TO A5TM C-90. D.STEEL-MINIMUM YIELD STRENGTH OF 33 K5I. MINIMUM 18 GA.WALL �d,•'•. THICKNESS. �iAiAti 11* PRo, tt3 N_ TLU r m m Z m ZZ Of u ILL J oN3ii'' a: a: k3Z 0 in lu DWG(##: Digitally signed by Hermes F.Norero,P.E. P WO 9 Reason:I am approving this dowment SHEET: OF /1 Date:2017,09.28 12:37:30-04'00' '7 Imam= 433 N.MAIN ST.,PO BOX 559, OE516N PRESSURE CHART ROCKY MOUNT,VA 21151 PH:540-484-6348 FX:540-484-6683 a0 WINDOW WIDTH WINDOW WIDTH a v# Y Maximum design pressure capacity chart(pso �< z MULL CLIP W/ W� _ ~>m S ANCHORS, Pro Classic Vertical Mullion(Twin)(hook and anchor plate) >� �;3- a TYP 3 Design pressures are limited either by mullion or anchor screvs or anchor clip capacity No o z o=LL GC U= wo Height Unit Width(in) ' m Z m WINDOW (in) 1&0 24.0 30.0 36.0 w o o < HEIGHT VERTICAL 17.0 50.0 50.0 50.0 50.0 d zz j Q< ��N 24.0 50.0 50.0 50.0 50.0 i m w a v y LU 30.0 50.0 50.0 50.0 50.0 a B 36.0 50.0 50.0 50.0 50.0 A 3 410 50.0 50.0 50.0 50.0 < N N 4&0 50.0 50.0 50.0 50.0 a o $ 54.0 50.0 50.0 50.0 50.0 f 60.0 50.0 50.0 50.0 48.4 00 ' 66.0 50.0 50.0 45.4 39.1 � 72.0 50.0 46.1 '47.7 32.3 Z VERTICAL MULLION FOR TWIN WINDOWS 0 Z SEE CHARTS ON SHEET 2 FOR DESIGN �u ^+ PRESSURES AND ANCHOR SCHEDULE F H NOTES FOR TWIN WINDOW AND DUAL 253273 HP MULL STEEL `H h REINFORCEMENTS WITH ANCHOR PLATE lI O Wu 1)THE DESIGN PRESSURES IN THIS CHART ARE FOR THE MULLIONS Uj U) 0 r LISTED ABOVE WHEN USED WITH THE CLIP LISTED ABOVE. w O LL CI Z w 2)FOR VERTICAL MULL CLIPS IN WOOD FRAMING INSTALLATION USE (3)THREE#8 WOOD SCREWS AT EACH ANCHOR CLIP.MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A 11/2'MINIMUM EMBEDMENT V p INTO FRAMING.SEE SHEET 3 FOR DETAILS. LL j 3)FOR VERTICAL MULL CLIPS IN MASONRY INSTALLATION USE(3)THREE Q m 3/16"ITW TAPCONS AT EACH ANCHOR CLIP WITH SUFFICIENT LENGTH 111 I TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE.SEE SHEET 3 FOR DETAILS. �� 0 4)FOR VERTICAL MULL CLIPS IN STEEL INSTALLATION USE(3)THREE#8 TEK Sj�.•'�••••••••• 5LRE WS,GRADE 5 AT EACH ANCHOR CLIP WITH SUFFICIENT LENGTH TO Q �!'• 6- ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND STEEL STRUCTURE. 5)CHART APPLIES ONLY TO DUAL 253273 HP STEEL REINFORCEMENT MULLIONS LL F AS SPECIFIED ABOVE WHEN USED TO MULL WINDOWS SIDE BY SIDE. ) �N 6)READ WINDOW WIDTH AND MULL SPAN IN INCHES.DESIGN PRESSURE 4 VALUES ON THIS CHART ARE POSITIVE AND NEGATIVE PSF. �i (S�,•• 7)DESIGN PRESSURE VALUES APPLY TO MULLION WHERE TWO OR MORE rrti 11 PRO% WINDOWS ARE LISTED IN A SINGLE OPENING. 8)REFER TO REPORT#5107 FOR MORE MULLION SPECIFICATIONS. ... Co Z DO Z J in 3 cz tb i= uZ < � o a v DW6#: PGW093 SHEET: 2 OF 4 SEE SHEET 2 FOR 2 1/2"MIN. ANCHOR TYPE AND QUANTITY EDGE DIST. a CONCRETE OR c d 133 N.MAIN ST..PO BOX 559, OTHERS EMBEDMENT MASONRY BY 1 MIN. ROCKY MOUNT,VA 24151 v PH'.540-484-6348 FX:540-464-6683 J � m ANCHOR PLATE uFtju z u#v �Lu i ° Hog 3 HZ d mJ 253273 HP MULL STEEL 'V). p EXTERIOR REINFORCEMENT Lu m w Q� m Ntm N atW -a<,z J a I d m O µl °p A � o VERTICAL SECTION = 3 (MASONRY,ANCHOR PLATE) m v�i 253273 HP MULL STEEL REINFORCEMENT,11GA (f� 3e VERTICAL SECTION 0 H z ° w o w ° JIx Z N Z h W�L Lp r o z w EXTERIOR LL � ° 1 1fi I% 253273 HP MULL STEEL �`��O a ""� REINFORCEMENT ANCHOR PLATE F ¢x 1 1/2"MIN. EMBEDMENT WOOD N T W FRAMING �"m co m z J`n BY OTHERS o N 3 Ot =2 - Z SEE SHEET 2 FOR 3/4"MIN. o o u ANCHOR TYPE AND EDGE DIST. DWG#: QUANTITY PG W09 3 eVERTICAL SECTION 3 (WOOD,ANCHOR PLATE) SHEET: 3 OF 4 f m �fL 0.0600 433 N.MAIN""PO BO .. II_ ROCKY MOUNT,VA 24151 0.2000 0.6250 T �_ i PM:540-484-6348 F%:540-484-6683 2069 0.5480 1. .0 1Z 8ki 3 3.7784 00.1740 TYP Ino p= a V)F4 w a<u ® ® ® 30* v a m w 0.959 �f m Z K ® ® ® ® d w � Z R L. 1.1250 �- 1/4" � a CO w 0.5000 � a 6.0000 DETAIL 2 d " SECTION VIEW OF ANCHOR PLATE DETAIL ANCHOR e ANCHOR PLATEN LOCATIONS o m � Z O O < w s w H Z V) L1J � o CY Z o w • V a W � O O o 2.7500 O 1 S l m o e 0.5370 1.1120 —{ o � L— I 1.0030 LL ' H • 0.5410---�---� �i��dr�'• ,••'DETAIL 3 (C DETAIL 4 11111 ISOMETRIC VIEW OF ANCHOR PLATE MULLION END m m Z m Z UJ V) a N 3 S S u Z DWG#: PGW093 SHEET: 4 OF 4