APPROVED Design Pressure Report
Property Information Owner:SHEPARD, KENNETH / CHERYL Address:9620 FAIRWOOD CT. PORT ST. LUCIE, FL. 34986 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:77 ft. Mean Roof Height:20 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 52 76 7 37.5 -40.9 2 End 52 61.5 7 38.1 -49.6 3 Int 51.75 25.75 7 40.2 -43.6 4 Int 51.75 61.75 7 38.1 -41.5 5 Int 51.75 25.75 7 40.2 -43.6 6 Int 51.75 61.75 7 38.1 -41.5 7 End 51.75 61.75 7 38.1 -49.6 8 Int 25.5 37.25 7 40.2 -43.6 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1