HomeMy WebLinkAboutAPPROVED PROJ-66992 - Furman Residence SealedREVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986 25.08 kW PV SYSTEMCODES AND STANDARDS8805 BALLY BUNION RD,PORT ST. LUCIE, FL 34986FURMAN RESIDENCEVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT SITEPROJECT DESCRIPTION:OWNERHOUSE PHOTOGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)ASCE 7-16FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)A-01ROOF PLANS-01MODULE LAYOUTS-02ATTACHMENT DETAILSTRUCTURE CALCULATIONE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGSHEET SHEET DESCRITIONCOVER SHEETA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:DESIGN CRITERIA:WIND SPEED (ULT): 160 MPHWIND SPEED (ASD): 124 MPHRISK CATEGORY:IIEXPOSURE:CRACKING: IRONRIDGE XR100 RAILATTACHMENT: IRONRIDGE KNOCKOUT TILE MOUNTS-01.1ARTIAL RESSURE AND MODULES EXOSURESUNPRO SOLAR4492 Eagle Falls Place,Tampa, FL 33619(866) 450-1012INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250, Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEERFURMAN, RICHARD66x380 LG NEON: LG380N1C-A6 (380W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESSYSTEM SIZE:25.080 kW DC STCARRAY AREA #1:468.08 SQ. FT.ARRAY AREA #2:370.57 SQ FT.ARRAY AREA #3:448.58 SQ FT.EQUIPMENT SUMMARY66 LG NEON: LG380N1C-A6 (380W) MODULES66 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERSS-02.1I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION.DS-01-09DATA SHEETSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.PROJECT SITES
Section..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessUM Utility MeterAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUNO Unless Noted OtherwiseVIF Verify In FieldWP Weather ProofGPGeneration PanelMDPMain Distribution PanelSDSoladeckNAVD North American Vertical datumMID Microgrid Interconnect DeviceSystem DescriptionThis system is a grid-tied, PV system, with PV generation consisting of66x380 LG NEON: LG380N1C-A6 (380W) Modules with a combined STC rated dcoutput power of 25,080W. The modules are connected into 66 ENPHASE:IQ7PLUS-72-2-US Microinverters. The inverter has electronic maximum powerpoint tracking to maximize energy captured by the PV modules. The inverter alsohas an internal ground fault detection and interruption device that is set todisconnect the array in the event that a ground fault that exceeds one ampereshould occur. The inverter has DC and AC disconnect integrated system and labelsare provided as required by the National Electrical Code.When the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used tocontribute to the power requirements of the occupancy. If PV power meets therequirements of the loads of the occupancy, any remaining PV power is sold backto the utility. When utility power is available, but PV power is not available,building loads are supplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramREVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986NOTES ANDDESCRIPTIONSymbols:Abbreviations:ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE125UPLIFT PRESSURE, 2 RAILS8868.5"41.0"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)LG NEON:LG380N1C-A6(380W) MODULES
137'-6
"83'-6"137'
-4
"77'-3"5'-0"25'
-0
"8'-10"53'-9
"ACDUMMDPACDCBSDREVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986ROOF PLANROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINESA-01SCALE: 1/16" = 1'-0"1FIRE ACCESS AND PATHWAYSAS PER NFPA 1, 11.12.21" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(N) SOLADECK(E) SERVICE POINT ANDUTILITY METERING(N) ALTERNATIVE POWER SOURCEAC DISCONNECT/RAPID SHUTDOWN(DISCONNECT 2 OF 2)- FIRE SETBACK - 3 FT- ZONING SETBACK - 2 FTALL MODULES TO BE INSTALLEDAT LEAST 2 FT AWAY FROM ALLTHE ROOF EDGESROOF #1(24) LG NEON: LG380N1C-A6(380W) MODULES(E) MAIN SERVICE DISCONNECT/ MAIN DISTRIBUTION PANELBALLY BUNION RD,EXIST
INGDRIVEWAY1-STORYHOUSE3'-0
"
F
IRE
SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FI
R
E
S
E
T
B
A
C
K
1'-6" FIR
E
S
E
T
B
A
C
K1'-6" FIRE SETBACK1'-6" FIRE SETBACK(N) PV COMBINER BOX(N)ALTERNATIVE POWER SOURCEAC DISCONNECT/RAPID SHUTDOWN(DISCONNECT 1 OF 2)(N) (66) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF #2(19) LG NEON: LG380N1C-A6(380W) MODULESROOF #3(23) LG NEON: LG380N1C-A6(380W) MODULESPOOL
87'-4
"67'-3"4'-0" TYP.REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986MODULE LAYOUTS-01SCALE: 1/16" = 1'-0"1MODULE LAYOUTGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING IS A S-TILE ROOF WITH AMEAN ROOF HEIGHT OF 15 FT AND SYP 2"X4" ROOF TRUSSESSPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEMRETROFIT IS 22.6 DEGREES. CONTRACTOR TO FIELD VERIFYAND SHALL REPORT TO THE ENGINEER IF ANYDISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS.3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18" EACHWAY FROM HIPS AND VALLEYS PER NFPA 1, 11.12.2. * I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED. CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERALAND UPLIFT FORCES AND EQUIPMENT DEAD LOADS. *WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14' - 0"1' - 4"4' - 0"1' - 4"ZONE 1'XXXXZONE 2e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 2nXXXXZONE 2r4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3rXXXXMODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 66 MODULESMODULE TYPE = LG NEON: LG380N1C-A6 (380W) MODULESMODULE WEIGHT = 41.01 LBS / 18.6 KG.MODULE DIMENSIONS = 68.5" x 41.0" = 19.50 SFUNIT WEIGHT OF ARRAY = 2.10 PSFARRAY AREA & ROOF AREA CALC'SROOFROOF TYPEARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSSPACING#1S-TILE468.081286.6936.3822.6°146°2"X4"24" O.C.#2S-TILE370.57801.8241.3522.6°236°2"X4"24" O.C.#3S-TILE448.58922.4148.6322.6°326°2"X4"24" O.C.LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)(159) PV ROOF ATTACHMENT@ 24" & 48" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)(N) IRONRIDGE XR100 RAIL (TYP.)(N) (66) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF #1(24) LG NEON: LG380N1C-A6(380W) MODULES(E) FRONT YARDROOF #1TILT
-
22.6
°AZIM
.
-
146
°(E) BACK YARDROOF #2(19) LG NEON: LG380N1C-A6(380W) MODULESROOF #3(23) LG NEON: LG380N1C-A6(380W) MODULESROOF #2TILT - 22.6°AZIM. - 236°ROOF #1TILT - 22.6°AZIM. - 326°
4'-0" TYP.36'-0
"9'-11"10'-1"7'-9"9'-2"8'-0
"8'-0"8'-1
"13'-2"7'-6"7'-0"13'-6"11'-8"12'-1"7'-8"7'-6"P1P2P3P4P5P6P7P8P9P10P11P12P13P14 P15P16P17P18P19P20REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986PARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: 1/16" = 1'-0"1ARTIAL RESSURE ANDMODULES EXOSURELEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)NOTE: PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.2h2DISTANCE : 1' - 0"0.5hDISTANCE : 7' - 6"- MISSING MODULEFOR EXPOSED MODULESFOR NON-EXPOSED MODULESALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 88 PSF2h2ROOF #1(24) LG NEON: LG380N1C-A6(380W) MODULES(E) FRONT YARD(E) BACK YARDROOF #2(19) LG NEON: LG380N1C-A6(380W) MODULESROOF #3(23) LG NEON: LG380N1C-A6(380W) MODULES0.5h
6"REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986ATTACHMENT DETAIL2S-02SCALE: 4" = 1'-0"ATTACHMENT DETAIL (ENLARGED VIEW)SOLAR MODULE(E) ROOF SHEATHINGS-TILE ROOFATTACHMENT DETAILS-02SCALE: 1" = 1'-0"12"X4" TRUSSES @ 24" O.C.GROUNDING MID/END CLAMP5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING2"X4" TRUSSES @ 24" O.C.2"X4" TRUSS SPANNER FORMISSED TRUSS SPANNER(IF REQUIRED)SEE (2/S-02) FORENLARGED VIEWIRONRIDGE KNOCKOUTTILE ATTACHMENTIRONRIDGE TILE REPLACEMENTFLASHING (S-TILE)5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMINGIRONRIDGE XR-100 RAILh2PV MODULE FRAMEIRONRIDGE XR100 RAILIRONRIDGE UNIVERSALFASTENING OBJECTPV MODULE FRAMEIRONRIDGE STOPPER SLEEVEIRONRIDGE UNIVERSALFASTENING OBJECT3DETAIL, MID CLAMP FRONTS-02Scale: 6"=1'-0"4DETAIL, END CLAMP(UFO) FRONTS-02Scale: 6"=1'-0"IRONRIDGE XR100 RAILAPPLY A GENEROUS AMOUNT OFKARNAK SEALANT PRIOR TO ATTACHMENTINSTALL COVERING AREA SIMILAR IN SIZETO THE FLASHING. SEE SHEET DS-08 FORSEALANT SPECS.
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986STRUCTURECALCULATION
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986ELECTRICALLINE DIAGRAM1ELECTRICAL LINE DIAGRAME-01SCALE: NTSSOLAR ARRAY (25.080 kW-DC STC)(66) LG NEON: LG380N1C-A6 (380W) MODULES(06) BRANCH OF 11 MODULESQ CABLESL2L1NL2L1GN20A/2PGG15A(N) SOLADECK600 V, NEMA 3RUL LISTEDGGGGGGGGGGPV MODULESENPHASE: IQ7PLUS-72-2-USMICROINVERTERSGGL2L1L2L1(N) JUNCTION BOX600 V, NEMA 3RUL LISTED(3) #10 AWG THWN-2 – RED(3) #10 AWG THWN-2 – BLACKEGC #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNGGGGGGGGGGL2L1L2L1L2L120A/2PGGGGGGGGGGGGL2L1L2L1L2L120A/2PGGGGGGGGGGGGGGGGGGGGGGGL2L1L2L1L2L1L2L1L2L120A/2PL2L120A/2P(N)PV COMBINER BOX,125A RATED, 240VGGGGGGGGGGGGGL2L1L2L1L2L120A/2P(3) 10/2 NMC RUN IN ATTIC(IN INTERIOR DRY LOCATION ONLY)OR(3) #10 AWG THWN-2-RED(3) #10 AWG THWN-2-BLACKEGC #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUN(3) 10/2 NMC RUN IN ATTIC(IN INTERIOR DRY LOCATION ONLY)OR(3) #10 AWG THWN-2-RED(3) #10 AWG THWN-2-BLACKEGC #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUN(3) #10 AWG THWN-2 – RED(3) #10 AWG THWN-2 – BLACKEGC #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(3) #12 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT, ENTCONDUIT RUN#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION,INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUMNUMBER OF MODULES PER STRING, MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL NUMBER, INVERTERMANUFACTURER AND MODEL NUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANELGUTTER SPACE IS INADEQUATE.3. IF THE FUSED AC DISCONNECT WIRE RUN EXCEEDS 10 FTFROM THE POINT OF INTERCONNECTION, CABLE LIMITERS ORCURRENT-LIMITED CIRCUIT BREAKERS MUST BE INSTALLEDFOR EACH UNGROUNDED CONDUCTOR PER NEC 705.31.4.REFER SHEET NUMBER DS-09 FOR LOAD CALCULATION.L2L1L2L1NNGGEXISTING GROUNDINGELECTRODE SYSTEMTO UTILITY GRIDL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NL1L2N(E) MAIN BREAKER200A/2P, 240VNL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NN100A100A/2PL1L2N(E)BI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240V(E) MAIN SERVICEDISCONNECT/ MAINDISTRIBUTION PANEL,200A RATED, 240V(3) #2 AWG THWN-2IN 1-1/2" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT, ENTCONDUIT RUNSUPPLY SIDE CONNECTION USINGINSULATION PIERCING OR POLARIS TAPSPER NEC 705.12(A)(N) ALTERNATIVE POWERSOURCE AC DISCONNECT /RAPID SHUTDOWN:240V, 100AMP RATED,NEMA 3R, UL LISTED(DISCONNECT 1 OF 2)(INTERIOR)(N) ALTERNATIVE POWERSOURCE AC DISCONNECT /RAPID SHUTDOWN:240V, 100AMP RATED,NEMA 3R, UL LISTEDLOCKABLE & NON FUSIBLE(DISCONNECT 2 OF 2 )(EXTERIOR)(3) #2 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1-1/2" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT, ENTCONDUIT RUN (N) 125A ENPHASE IQCOMBINER 3 (X-IQ-AM1-240-3)[WITH UPTO (4) 2-POLEBREAKERS AND ENVOYCOMMUNICATION GATEWAY]NL2L1GNGG
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986 ELECTRICAL CALCULATIONELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.19.ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOFSURFACE.WIRING CALCULATIONSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION.
ACDUMMDPACDCBREVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986SYSTEM LABELINGTURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSPHOTOVOLTAIC SYSTEMWITH RAPIDSHUTDOWN SWITCHLABEL LOCATION:AC DISCONNECT(PER CODE: NEC 690.56(C)(3))LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 79.8 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTS! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!AC DISCONNECT25.08 KW SOLARDISCONNECT LOCATEDPHOTOVOLTAICSYSTEM MICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYAC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)LABEL LOCATION:INVERTER(PER CODE: NEC 690.52)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE VISIBLE, REFLECTIVE AND SUITABLE FORTHE ENVIRONMENT WHERE IT IS INSTALLED [NFPA 1, 11.12.2.1]· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]SOLAR CONNECTIONLINE SIDE TAPLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(A))WARNING:POWER SOURCE OUTPUT CONNECTION DONOT RELOCATE THIS OVERCURRENT DEVICENOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)DATA PER PANELCAUTION!POWER TO THIS BUILDINGSUPPLIED FROM MULTIPLE SOURCES EMERGENCY RESPONDER:THIS SOLAR PV SYSTEM IS EQUIPPEDWITH RAPID SHUTDOWN.TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''POSITION TO SHUTDOWN ENTIRE PV SYSTEM8805 BALLY BUNION RD, PORT ST. LUCIE, FL 34986WARNINGIN CASE OF EMERGENCY, CONTACT:SUNPRO SOLARPH. NO. : (866) 450-1012LABEL LOCATION:MAIN DISCONNECT(PER CODE: NFPA - 1, 11.12.2.1.5)!!LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 1204.5.1LABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECTLOCATED NO MORE THAN 3FT (1M) FROM THE SERVICE DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NEC 690.56(B), NEC 705.10, NFPA 1, 11.12.2.1)LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))PV SOLAR ARRAYON ROOFSERVICE POINT ANDUTILITY METERINGMAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANELPV COMBINER BOXALTERNATIVE POWER SOURCE ACDISCONNECT/RAPID SHUTDOWN(DISCONNECT 2 OF 2)ALTERNATIVE POWERSOURCE ACDISCONNECT/RAPIDSHUTDOWN(DISCONNECT 1 OF 2)
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-07CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-08CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERFURMAN RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-09CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC8805 BALLY BUNION RD,
PORT ST. LUCIE, FL 34986DATA SHEET