Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeF8F-zM 405-T0 'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: dennis and brenda balser Builder Name: L & C CONSTRUCTION Street: 10725 S OCEAN DRIVE LOT #4 Permit Office: st. lucie co. / ft. pierce City, State, Zip: , FL, 34957- Permit Number: Owner: SAME Jurisdiction: 661100 Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (3798.7 sqft.) Insulation Area 2. Single family or multiple family Single-family P. Concrete Block - Ext Insul, Exterior R=4.0 2632.70 ft2 b. Concrete Block - Ext Insul, Exterior R=11.0 1166.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (917.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 917.00 ft2 6. Conditioned floor area above grade (ft2) 1561 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(305.7 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 164 a. U-Factor: Dbl, U=0.40 285.73 ft2 SHGC: SHGC=0.40 b. U-Factor: Dbl, U=0.55 20.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.60 a. Central Unit 36.8 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 2.892 ft. Area Weighted Average SHGC: 0.413 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1834.0 sqft.) Insulation Area EF: 0.920 a. Floor Over Other Space R=20.0 917.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 917.00 ft2 None c. N/A R= ft2 15. Credits CF, CV, Pstat Total Proposed Modified Loads: 33.18 Glass/Floor Area: 0.196 PASS Total Standard Reference Loads: 49.22 I hereby certify that the plans and specifications covered by Review of the plans and - -00 S7- Ws calculation are in compliance with the FI rida Energy specifications covered by this �� Code. calculation indicates compliance PREPARED BY: with the Florida Energy Code. Before construction is completed fill, - DATE: this building will be inspected for compliance with Section 553.908 1 hereby certi that thit building, as designed, is in compliance Florida Statutes. ✓�, �� COD with the Florida Energy Code. WME S� , OWNER/AGENT: rC� BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Compliance requires a roof absorptance test in accordance with 405.6.2 7/28/201510:44 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: dennis and brenda balser Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1561 Lot # 4 Owner: SAME Total Stories: 2 Block/SubDivision: BLK. A # of Units: 1 Worst Case: No PlatBook: 14 PAGE 28 Builder Name: L & C CONSTRUCTION Rotate Angle: 0 Street: 10725 S OCEAN DRIV Permit Office: st. lucle co. / ft. pierce Cross Ventilation: Yes County: st. lucie Jurisdiction: 661100 Whole House Fan: No City, State, Zip: , Family Type: Single-family FL, 34957- New/Existing: New (From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree. Days Moisture Range FL, Fort Pierce FL_ST LUCIE_CO INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1561 9268 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 917 7336 Yes 2 3 1 Yes Yes No 2 Crawlspace 644 1932 No 2 0 1 Yes Yes No FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor Over Other Space Main ___- -- 917 ft2 20 0.5 0.5 0 2 Slab -On -Grade Edge Insulatio Crawlspace 135 ft 0 917 ft2 -- 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 966 ft2 0 ft2 Medium 0.96 Yes 0.9 No 20 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 917 ft2 N N 7/28/201510:44 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 20 917 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ornt To Wall Type R-Atalue Et In Ft In Area R-Alahle Fraction9 AbS 1 E Exterior Concrete Block - Ext Insul Main 4 31 8 8 253.3 ft2 0 0 0.75 0 -2 N Exterior Concrete Block - Ext Insul Main 4 11 5 8 0 91.3 ft2 0 0 0.75 0 3 E Exterior Concrete Block - Ext Insul Main 4 4 8 8 0 37.3 ft2 0 0 0.75 0 4 N Exterior Concrete Block - Ext Insul Main 4 8 11 8 0 71.3 ft2 0 0 0.75 0 _ 5 E Exterior Concrete Block - Ext Insul Main 4 42 8 8 0 341.3 ft2 0 0 0.75 0 _ 6 S Exterior Concrete Block - Ext Insul Main 4 24 10 8 0 198.7 ft2 0 0 0.75 0 _ 7 W Exterior Concrete Block - Ext Insul Main 4 42 8 8 0 341.3 ft2 0 0 0.75 0 8 N Exterior Concrete Block - Ext Insul Main 4 24 10 8 0 198.7 ft2 0 0 0.75 0 -9 E Exterior Concrete Block - Ext Insul Main 4 42 8 8 0 341.3 ft2 0 0 0.75 0 10 S Exterior Concrete Block - Ext Insul Main 4 9 5 8 0 75.3 ft2 0 0 0.75 0 11 E Exterior Concrete Block - Ext Insul Main 11 6 7 8 0 52.7 ft2 0 0 0.5 0 12 S Exterior Concrete Block - Ext Insul Main 11 4 4 8 0 34.7 ft2 0 0 0.5 0 _ 13 E Exterior Concrete Block - Ext Insul Main 11 6 10 8 0 54.7 ft2 0 0 0.5 0 _ 14 S Exterior Concrete Block - Ext Insul Main 11 2 9 8 0 22.0 ft2 0 0 0.5 0 _ 15 E Exterior Concrete Block - Ext Insul Main 11 3 9 8 0 30.0 ft2 0 0 0.5 0 _ 16 N Exterior Concrete Block - Ext Insul Main 11 2 9 8 0 22.0 ft2 0 0 0.5 0 _ 17 S Exterior Concrete Block - Ext Insul Main 11 118 9 8 0 950.0 ft2 0 0 0.5 0 18 E Exterior Concrete Block - Ext Insul Main 4 42 8 8 0 341.3 ft2 0 0 0.75 0 _ 19 E Exterior Concrete Block - Ext Insdlrawlspace 4 42 8 8 0 341.3 ft2 0 0 0.75 0 DOORS # Ornt Door Type Space StoFms U-Value Width Height Area Ft In Ft In 1 S Wood Main Wood .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Double (Tinted) Yes 0.4 0.4 22.8 ft2 1 ft 0 in 8 ft 0 in Drapes/blinds None 2 N 2 Metal Double (Tinted) Yes 0.4 0.4 40.0 ft2 9 ft 0 in 0 ft 8 in Drapes/blinds None 3 E 3 Metal Double (Tinted) Yes 0.4 0.4 20.0 ft2 14 ft 5 in 0 ft 8 in Drapes/blinds None 4 E 5 Metal Double (Tinted) Yes 0.4 0.4 23.2 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 5 S 6 Metal Double (Tinted) Yes 0.4 0.4 46.4 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 6 W 7 Metal Double (Tinted) Yes 0.4 0.4 19.5 ft2 0 ft 6 in 10 ft 5 in Drapes/blinds None 7 N 8 Metal Double (Tinted) Yes 0.4 0.4 77.1 ft2 1 ft 0 in 10 ft 5 in Drapes/blinds None 8 E 9 Metal Double (Tinted) Yes 0.4 0.4 36.8 ft2 1 ft 0 in 10 ft 5 in Drapes/blinds None 9 S 10 Metal Double (Tinted) Yes 0.55 0.6 20.0 ft2 1 ft 0 in 10 ft 5 in Drapes/blinds None 7/28/2015 10:44 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant -Software Page 3 of 5 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 i Wholehouse Best Guess .0003 1228.4 67.44 126.82 .2696 7.9523 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 164 ft2 Main 41 ft2 Default Leakage Main (Default) (Default) No 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Heating r jJanr Feb Mar Mar 1Feb Rj f A r Ma Jun Jul Au Xj Ap`MMay Jun JulX� Aug [X] Se [X] Sep Oct Nov X Dec Jan Feb Mar [X [X [X Jun [X Jul [X Aug [Xl Sep OctXj NovX DecVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Wafts HRV Heating System Run Time Cooling System None 0 0 0 0 - 0% 1- Central Unit 7/28/2015 10:44 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10725 S OCEAN DRIVE LOT #4 PERMIT #: , FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 7/28/2015 10:44 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5