HomeMy WebLinkAboutEnergy Efficiency CodeF8F-zM 405-T0
'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: dennis and brenda balser
Builder Name: L & C CONSTRUCTION
Street: 10725 S OCEAN DRIVE LOT #4
Permit Office: st. lucie co. / ft. pierce
City, State, Zip: , FL, 34957-
Permit Number:
Owner: SAME
Jurisdiction: 661100
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (3798.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
P. Concrete Block - Ext Insul, Exterior
R=4.0 2632.70 ft2
b. Concrete Block - Ext Insul, Exterior
R=11.0 1166.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (917.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 917.00 ft2
6. Conditioned floor area above grade (ft2) 1561
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(305.7 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 164
a. U-Factor: Dbl, U=0.40 285.73 ft2
SHGC: SHGC=0.40
b. U-Factor: Dbl, U=0.55 20.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.60
a. Central Unit
36.8 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 2.892 ft.
Area Weighted Average SHGC: 0.413
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1834.0 sqft.) Insulation Area
EF: 0.920
a. Floor Over Other Space R=20.0 917.00 ft2
b. Conservation features
b. Slab -On -Grade Edge Insulation R=0.0 917.00 ft2
None
c. N/A R= ft2
15. Credits
CF, CV, Pstat
Total Proposed Modified Loads: 33.18
Glass/Floor Area: 0.196
PASS
Total Standard Reference Loads: 49.22
I hereby certify that the plans and specifications covered by
Review of the plans and
- -00 S7-
Ws calculation are in compliance with the FI rida Energy
specifications covered by this
��
Code.
calculation indicates compliance
PREPARED BY:
with the Florida Energy Code.
Before construction is completed
fill,
-
DATE:
this building will be inspected for
compliance with Section 553.908
1 hereby certi that thit building, as designed, is in compliance
Florida Statutes.
✓�, ��
COD
with the Florida Energy Code.
WME
S� ,
OWNER/AGENT: rC�
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Compliance requires a roof absorptance test in accordance with 405.6.2
7/28/201510:44 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
Title:
dennis and brenda balser Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1561
Lot #
4
Owner:
SAME
Total Stories: 2
Block/SubDivision:
BLK. A
# of Units:
1
Worst Case: No
PlatBook:
14 PAGE 28
Builder Name:
L & C CONSTRUCTION Rotate Angle: 0
Street:
10725 S OCEAN DRIV
Permit Office:
st. lucle co. / ft. pierce
Cross Ventilation: Yes
County:
st. lucie
Jurisdiction:
661100
Whole House Fan: No
City, State, Zip:
,
Family Type:
Single-family
FL, 34957-
New/Existing:
New (From Plans)
Comment:
CLIMATE
V
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree. Days Moisture
Range
FL, Fort Pierce FL_ST LUCIE_CO INTL 2 39 90
70
75 722
62
Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1561 9268
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
Main
917 7336 Yes 2
3
1 Yes
Yes
No
2
Crawlspace
644 1932 No 2
0
1 Yes
Yes
No
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Floor Over Other Space
Main ___- --
917 ft2
20
0.5 0.5
0
2 Slab -On -Grade Edge Insulatio Crawlspace 135 ft 0
917 ft2
--
0 0
1
ROOF
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 966 ft2 0 ft2 Medium
0.96
Yes 0.9
No 20
18.4
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0
917 ft2
N N
7/28/201510:44 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
CEILING
#
Ceiling Type
Space
R-Value
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
Main
20
917 ft2
0.11
Wood
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar
Below
Ornt
To
Wall Type
R-Atalue
Et
In
Ft In
Area
R-Alahle
Fraction9 AbS
1
E
Exterior
Concrete Block - Ext Insul
Main
4
31
8
8
253.3 ft2
0
0 0.75
0
-2
N
Exterior
Concrete Block - Ext Insul
Main
4
11
5
8 0
91.3 ft2
0
0 0.75
0
3
E
Exterior
Concrete Block - Ext Insul
Main
4
4
8
8 0
37.3 ft2
0
0 0.75
0
4
N
Exterior
Concrete Block - Ext Insul
Main
4
8
11
8 0
71.3 ft2
0
0 0.75
0
_ 5
E
Exterior
Concrete Block - Ext Insul
Main
4
42
8
8 0
341.3 ft2
0
0 0.75
0
_ 6
S
Exterior
Concrete Block - Ext Insul
Main
4
24
10
8 0
198.7 ft2
0
0 0.75
0
_ 7
W
Exterior
Concrete Block - Ext Insul
Main
4
42
8
8 0
341.3 ft2
0
0 0.75
0
8
N
Exterior
Concrete Block - Ext Insul
Main
4
24
10
8 0
198.7 ft2
0
0 0.75
0
-9
E
Exterior
Concrete Block - Ext Insul
Main
4
42
8
8 0
341.3 ft2
0
0 0.75
0
10
S
Exterior
Concrete Block - Ext Insul
Main
4
9
5
8 0
75.3 ft2
0
0 0.75
0
11
E
Exterior
Concrete Block - Ext Insul
Main
11
6
7
8 0
52.7 ft2
0
0 0.5
0
12
S
Exterior
Concrete Block - Ext Insul
Main
11
4
4
8 0
34.7 ft2
0
0 0.5
0
_ 13
E
Exterior
Concrete Block - Ext Insul
Main
11
6
10
8 0
54.7 ft2
0
0 0.5
0
_ 14
S
Exterior
Concrete Block - Ext Insul
Main
11
2
9
8 0
22.0 ft2
0
0 0.5
0
_ 15
E
Exterior
Concrete Block - Ext Insul
Main
11
3
9
8 0
30.0 ft2
0
0 0.5
0
_ 16
N
Exterior
Concrete Block - Ext Insul
Main
11
2
9
8 0
22.0 ft2
0
0 0.5
0
_ 17
S
Exterior
Concrete Block - Ext Insul
Main
11
118
9
8 0
950.0 ft2
0
0 0.5
0
18
E
Exterior
Concrete Block - Ext Insul
Main
4
42
8
8 0
341.3 ft2
0
0 0.75
0
_ 19
E
Exterior
Concrete Block - Ext Insdlrawlspace
4
42
8
8 0
341.3 ft2
0
0 0.75
0
DOORS
#
Ornt
Door Type Space
StoFms
U-Value
Width
Height
Area
Ft In
Ft In
1
S
Wood Main
Wood
.46
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
E 1
Metal Double (Tinted)
Yes
0.4
0.4
22.8 ft2
1 ft 0 in
8 ft 0 in
Drapes/blinds
None
2
N 2
Metal Double (Tinted)
Yes
0.4
0.4
40.0 ft2
9 ft 0 in
0 ft 8 in
Drapes/blinds
None
3
E 3
Metal Double (Tinted)
Yes
0.4
0.4
20.0 ft2
14 ft 5 in
0 ft 8 in
Drapes/blinds
None
4
E 5
Metal Double (Tinted)
Yes
0.4
0.4
23.2 ft2
1 ft 0 in
0 ft 8 in
Drapes/blinds
None
5
S 6
Metal Double (Tinted)
Yes
0.4
0.4
46.4 ft2
1 ft 0 in
0 ft 8 in
Drapes/blinds
None
6
W 7
Metal Double (Tinted)
Yes
0.4
0.4
19.5 ft2
0 ft 6 in
10 ft 5 in
Drapes/blinds
None
7
N 8
Metal Double (Tinted)
Yes
0.4
0.4
77.1 ft2
1 ft 0 in
10 ft 5 in
Drapes/blinds
None
8
E 9
Metal Double (Tinted)
Yes
0.4
0.4
36.8 ft2
1 ft 0 in
10 ft 5 in
Drapes/blinds
None
9
S 10
Metal Double (Tinted)
Yes
0.55
0.6
20.0 ft2
1 ft 0 in
10 ft 5 in
Drapes/blinds
None
7/28/2015 10:44 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant -Software Page 3 of 5
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH
ACH 50
i Wholehouse
Best Guess
.0003 1228.4 67.44 126.82
.2696
7.9523
HOT WATER SYSTEM
# System Type SubType
Location EF Cap Use
SetPnt
Conservation
1 Electric None
Main 0.92 40 gal 40 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
V
— Supply —
— Return — Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location Area Leakage Type Handler TOT
OUT
ON
RLF
Heat Cool
1
Attic 6 164 ft2
Main 41 ft2 Default Leakage Main
(Default) (Default)
No 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan
Heating r jJanr
Feb Mar
Mar
1Feb Rj
f
A r Ma Jun Jul Au
Xj Ap`MMay Jun JulX� Aug
[X] Se
[X] Sep
Oct
Nov
X Dec
Jan
Feb Mar
[X
[X [X Jun [X Jul [X Aug
[Xl Sep
OctXj
NovX
DecVenting
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6 7
8
9
10
11
12
Cooling (WD)
AM 78
78
78 78 78 78 78
78
80
80
80
80
PM 80
80
78 78 78 78 78
78
78
78
78
78
Cooling (WEH)
AM 78
78
78 78 78 78 78
78
78
78
78
78
PM 78
78
78 78 78 78 78
78
78
78
78
78
Heating (WD)
AM 66
66
66 66 66 68 68
68
68
68
68
68
PM 68
68
68 68 68 68 68
68
68
68
66
66
Heating (WEH)
AM 66
66
66 66 66 68 68
68
68
68
68
68
PM 68
68
68 68 68 68 68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM Fan Wafts HRV Heating System
Run Time
Cooling System
None
0
0 0 0 -
0%
1- Central Unit
7/28/2015 10:44 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 10725 S OCEAN DRIVE LOT #4 PERMIT #:
, FL, 34957-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
7/28/2015 10:44 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5