Loading...
HomeMy WebLinkAboutLetter ( Hangers For Girders )• Donald J. Nuelle P.E. 815 University Boulevard Apt. 301 Jupiter, FI. 33458 Mr. & Mrs. Balser Lot 4 Holiday Out St. Lucie County, FL RE: Hangers for Girders that frame into the MCU Walls Dear Mr. Balser, Date: 8/9/2015 After reviewing the truss package from Al truss all 2 ply floor girders that frame into the wall and don't bear shall be supported by a Simpson LGUM26-2- sds. All 3 ply floor girders shalFbear on Simpson LGUM36-3-sds. All connectors shall be installed according -to manufacturer's recommendations. If you or any other affected party have any questions or require additional information please contact me at (561)-629-6975. ero Donald J. uelle P.E. 52046 l ., '•mac X 1 �f A-1. ROOF TRUSSES A FLORIDA CORPORATION Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 These truss designs rely on lumber values established by others. RE: Job 61998 A-1 Roof Trusses 4451 St Lucie Blvd Site Information: Fort Pierce, FL 34946 Customer Info: L&C CONSTRUCTION INC. Project Name: BALSER RESIDENCE Lot/Block: Model: BALSER RESIDENCE Address: LOT 4 HOLIDAY OUT, JENSEN BEACH, Fl-wbdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2014ITP12007 Design Program: MiTek 20/20 7.6 Wind Code: ASCE 7-10 Wind Speed: 170 MPH Roof Load: 55.0 psf Floor Load: 55.0 psf This package includes 92 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss 'Name Date 1 A0556593 A01 G 7/31/15 13 A0556605 FL06 7/31/15 25 A0556617 FL18 7131 /15 2 A0556594 A02 7/31/15 14 A0556606 FL07G 7131115 26 A0556618 FL19 7/31/15 3 A0556595 A03 7/31/15 15 A0556607 FL08 7/31/15 27 A0556619 FL20 7/31/15 4 A0556596 A04 7/31/15 16 A0556608 FL09 7/31/15 28 A0556620 FL21 7/31/15 5 A0556597 A05 7/31/15 17 A0556609 FL10 7/31/15 29 A0556621 FL22 7/31/15 6 A0556598 A06 7/31/15 18 A0556610 FL11 7/31/15 30 A0556622 FL23G 7/31115 7 A0556599 A07G 7/31/15 19 A0556611 FL12 7/31/15 31 A0556623 FL24 7/31/15 8 A0556600 FL01G 7/31/15 20 A0556612 FL13 7/31/15 32 A0556624 FL27G 7/31/15 9 A0556601 FL02 7/31/15 21 A0556613 FL14G 7/31/15 33 A0556625 FL28 7131/15 10 A0556602 FL03G 7/31/15 22 A0556614 FL15G 7/31/15 34 A0556626 FL29G 7/31/15 11 A0556603 FL04 7/31/15 23 A0556615 FL16 7/31/15 35 A0556627 FL30G 7/31/15 12 A0556604 FL05G 7/31/15 24 1 A0556616 FL17 7/31/15 36 IA0556628 FL31 7/31/15 The truss drawing(s) referenced have been prepared by MiTek Industries, Inc, under my direct supervision based on the parameters provided by AA Roof Trusses, Ltd. Truss Design Engineer's Name: Manuel Martinez My license renewal date for the state of Florida is February28,2017. NOTE: The seal on these drawings Indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of components for any particular building is the responsibility of the building designer, perANSVTPI-1 Sea 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to at times as 'Structural Engineering Documents') provided by the Building Indicating the nature and character of the work. The design criteria therein have been transferred to Manuel Martinez PE by [A1 Roof Trusses orspecifle location]. These TDDs (also referred to at times Structural Delegated Engineering Documents') are specialty structural component designs and may be part of the project's deferred orphased submittals. As a Truss Design Engineer (i.e., Specialty Engineer), the seal here and on the Too represents an acceptance of professional engineering responsibility forthe design of the single Truss depicted an the Too only. The Building Designer is responsible for and shag coordinate and review the TDDs for compatibility with their written engineering requirements. Please review all TDDs and all related notes. Manuel `D9�Ya9^dbYManuN Mart n¢ WAmT�u#A�5 &alre.s ( ftp {l uve,a�MANOE MartinezSW'sRepresenb9mazso ront��aw .• Jill. MARTS •,. No 047162 .✓/�� �, STATE OF :(U =9 /EWl Page 1 of 2