HomeMy WebLinkAboutCertification Of Insulation- a insulation a MASCO Company CERTIFICATION OF INSULATION N R-_y. I INSULATION INSTALLED ON EXTERIOR WALLS 0 INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot Block PERMIT #: 13 Q� - 00 g0 Sub -Division. JOBADDRESS:. � �eqo P1 PC 3CtIN9 BUILDER: f h Ne n I GALE W/O: ATTESTED BY: DATE: (' , �_ - / L-/ 9 7,A C_ RECEIVED JUL 16 2014 'Lld 3601 -A CROSSROADS PARKWAY FT. PIERCE, FL 34945 FT. PIERCE (772) 466-9191 o VERO BEACH (772) 589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: A. private Residence Builder Name: Street: Permit Office: St. Lucie County City, State, Zip: Hutchinson Island, FI , Permit.Number. Owner. Jurisdiction: 661000 Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types(6692.4 sgft.) Insulation Area 2.. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 6188.40 ft2 b. Frame - Steel, Exterior R=11.0 273.00 ft2 3. Number of units, if multiple family 1 c. Concrete Block - Int Insul, Exterior R=13.0 231.00 ft2 4. Number of Bedrooms 4 d. N/A 12= ft2 5. Is this a worst case? No 10. Ceiling Types (2599.0 sqft.) Insulation Area a. Cathedral/Single Assembly (Unvented) R=30.0 2599.00 ft2 6. Conditioned floor area above grade (ft2) 5100 b. NIA R= ft2 Conditioned floor area below grade (ftz) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(1373.0 sqft.) Description Area a. Sup: Main, Ret: Main, AH: Main 6 146 a. U-Factor: ON, U=0.65 1373.00 ft2 b. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 121 SHGC: SHGC=0.30 c. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 294 b. U-Factor. N/A ft2 12. Cooling systems kStu/hr Efficiency SHGC: a. Central Unit 35.8 SEER:19.00 c. U-Factor. NIA ft2 b. Central Unit c. Central Unit 46.4 SEER:18.00 47.0 SEER:18.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a. Electric Heat Pump 41.0 HSPF:8.20 SHGC: b. Electric Heat Pump 49.0 HSPR8.50 Area Weighted Average Overhang Depth: 5.198 ft. c. Electric Heat Pump 49.1 HSPF:8.50 Area Weighted Average SHGC: 0.300 14.. Hot water systems 8. Floor Types (5100.0 sgft:) Insulation Area a. Electric Cap: 85 gallons a. Raised Floor R=19.0 3027.00 ft2 b. Conservation features EF: 0.960 b. Raised Floor R=0.0 2073.06 ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.269 Total Proposed Modified Loads: 80.44 ®ASS Total Standard Reference Loads: 116.63 r I hereby certify that the plans and specifications covered by Review of the plans and ST'AT� this calculation are in compliance with the Florida Energy specifications covered by this o--tSE , , p Code. � 7 PREPARED BY: _ calculation indicates compliance with the Florida Energy Code. Before construction is completed yii,,'�%',����.�+ v DATE:r�� _ this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as de ' ned, is in compliance Florida Statutes. with the Florida Energy C d CpD.�ty OWNER/AGENT: _ BUILDING OFFICIAL: DATE: �- - L 2 _ _ DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #3 may be undersized. Size of 49.1 was increased to 51.6 for simulation. Please review the Manual J8 report- Cool sys #2 may be undersized. Size of 46.4 was increased to 46.4 for simulation. Please review the Manual J8 report. 8/6/2012 11:15 AM EnergyGaugeS USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7 '65' 4 i..5 2.5" 0.5" TAPERED, SECTION SLOPE 2 PANEL. SYSTEM NOT Tb SCALE. v 4:5" CRICKET SECTION 112"tFT. -SLOPE I PANEL SYSTEM -NIOT TO SCALE DatC Inc Lu Lu t It T"EIND SOLUTIONS, 1542APE)(RD SAR,ASOT.A'LFL 34240 OFF.;BG.D-627-37-OZ FAX. BM014-5059 t*brd"gh6in@ABCsupply.com pArr I