HomeMy WebLinkAboutCertification Of Insulation-
a
insulation
a MASCO Company
CERTIFICATION OF INSULATION
N
R-_y. I INSULATION INSTALLED ON EXTERIOR WALLS
0 INSULATION INSTALLED IN CEILING AREAS
LEGAL: Lot Block
PERMIT #: 13 Q� - 00 g0
Sub -Division.
JOBADDRESS:. � �eqo P1 PC 3CtIN9
BUILDER: f h Ne n I
GALE W/O:
ATTESTED BY:
DATE: (' , �_ - / L-/
9 7,A C_
RECEIVED JUL 16 2014
'Lld
3601 -A CROSSROADS PARKWAY FT. PIERCE, FL 34945
FT. PIERCE (772) 466-9191 o VERO BEACH (772) 589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: A. private Residence
Builder Name:
Street:
Permit Office: St. Lucie County
City, State, Zip: Hutchinson Island, FI ,
Permit.Number.
Owner.
Jurisdiction: 661000
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types(6692.4 sgft.)
Insulation Area
2.. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 6188.40 ft2
b. Frame - Steel, Exterior
R=11.0 273.00 ft2
3. Number of units, if multiple family 1
c. Concrete Block - Int Insul, Exterior
R=13.0 231.00 ft2
4. Number of Bedrooms 4
d. N/A
12= ft2
5. Is this a worst case? No
10. Ceiling Types (2599.0 sqft.)
Insulation Area
a. Cathedral/Single Assembly (Unvented) R=30.0 2599.00 ft2
6. Conditioned floor area above grade (ft2) 5100
b. NIA
R= ft2
Conditioned floor area below grade (ftz) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(1373.0 sqft.) Description Area
a. Sup: Main, Ret: Main, AH: Main
6 146
a. U-Factor: ON, U=0.65 1373.00 ft2
b. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 121
SHGC: SHGC=0.30
c. Sup: Attic, Ret: Attic, AH: 2nd Floor
6 294
b. U-Factor. N/A ft2
12. Cooling systems
kStu/hr Efficiency
SHGC:
a. Central Unit
35.8 SEER:19.00
c. U-Factor. NIA ft2
b. Central Unit
c. Central Unit
46.4 SEER:18.00
47.0 SEER:18.00
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor N/A ft2
a. Electric Heat Pump
41.0 HSPF:8.20
SHGC:
b. Electric Heat Pump
49.0 HSPR8.50
Area Weighted Average Overhang Depth: 5.198 ft.
c. Electric Heat Pump
49.1 HSPF:8.50
Area Weighted Average SHGC: 0.300
14.. Hot water systems
8. Floor Types (5100.0 sgft:) Insulation Area
a. Electric
Cap: 85 gallons
a. Raised Floor R=19.0 3027.00 ft2
b. Conservation features
EF: 0.960
b. Raised Floor R=0.0 2073.06 ft2
None
c. NIA R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.269 Total Proposed Modified Loads: 80.44
®ASS
Total Standard Reference Loads: 116.63
r
I hereby certify that the plans and specifications covered by
Review of the plans and
ST'AT�
this calculation are in compliance with the Florida Energy
specifications covered by this
o--tSE
, , p
Code.
� 7
PREPARED BY: _
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
yii,,'�%',����.�+
v
DATE:r�� _
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as de ' ned, is in compliance
Florida Statutes.
with the Florida Energy C d
CpD.�ty
OWNER/AGENT: _
BUILDING OFFICIAL:
DATE: �- - L 2 _ _
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Heat sys #3 may be undersized. Size of 49.1 was increased to 51.6 for simulation. Please review the Manual J8 report- Cool sys
#2 may be undersized. Size of 46.4 was increased to 46.4 for simulation. Please review the Manual J8 report.
8/6/2012 11:15 AM EnergyGaugeS USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7
'65'
4 i..5
2.5"
0.5"
TAPERED, SECTION
SLOPE
2 PANEL. SYSTEM
NOT Tb SCALE.
v
4:5"
CRICKET SECTION
112"tFT. -SLOPE
I PANEL SYSTEM