Loading...
HomeMy WebLinkAboutCertificate For Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 4��Eu MAY 2 2 v Certification for Design Load Compliance Project Name: 12 Gr i d c nc c -- Project Address: Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that ap0 )- 1. DESIGN CODE: Florida (S wrl� tic_ Code 2010 Edition with 20 / supplements using ASCE 7-10 2. Structure Designed as (check one): / '� Enclosed Partially Enclosed Open 3. Risk Category: _I -� II III IV Exposure Category: B C ✓ D 4. Design Wind Velocity I'Co'5 mph ASD ✓ LRFD End Zone Width: Y. 3 ft 5. Mean Roof Height 1 (10 ft Roof Pitch: _:12 Parapet: N�ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: rid . 0 Zone 2: 0, b Zone 3: 103, O Zone 4: Y 7. Y Zone 5: 5$.S Garage: r-),,A 7. Design Loads: Floor: PSF Roof/Dead: 2 S PSF Roof/Live:;?, o Balcony: 60 PSF Dock: PSF Deck: Ka PSF Stairs: ''(o PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? K Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2 So a PSF Soil Test Reports Submitted? K_Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: 5 /l 1S Signat e, Date, and Seal SLCCDV Form # 020-12 Revised 3/15/12 (JS) Print Name ^^ Cert # & Co. Cert Auth. Leo A✓L_ d (Iac�Dirnt� SiY Z(eb f-d, 6cac-L GcrJtA; F-L 33` I'T Company Name & Address L5 F, Lk -.�Y