Loading...
HomeMy WebLinkAboutDensity & Water Content Of Soil Test521 NW Enterprise Drive • Port St. Lucie, Florida 34986 (772) 924-3575 • (772) 924-3580 (fax) �GjFRNAT\GAP IN -PLACE DENSITY AND WATER CONTENT OF SOIL AND SOIL AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) - ASTM 6938 Project: Shoreline Mobile Home Repair - Various Projects Project ID: 14-1689.00 Address: Various _ Report ID: D-0006 Client: Shoreline Mobile Home Repair _ Date: 7/16/2015 Permit No: Field Tech: Daniel Decaro Test Mode: Direct Transmission Area Tested: 1335 Nettles Blvd., Jensen Beach - Footings (PERMIT N 1505'0356) Soil Description: Brown fine sand some rock Proctor / LBR ID: P-2 Max Density (PCF): 110.0 Opt Moisture (%): 10.0% Test Standard: D 1557 Compaction Required (%): 95.0% Probe Depth (in) Elev Wet Density (PCF) Dry Density (PCF) Moist. (%) Compaction Location oho Results Northwest 12 0-1 118.7 109.6 8.3% 99.6% Pass Southeast 12 0-1 118.8 109.1 8.9% 99.2% Pass Southwest 12 0-1 119.8 109.4 9.5% 99.5% Pass These tests and all previous tests do not certify the subgrade soils have a safe bearing capacity. F ECEIV D DEC ..1 2015 No soil borings were completed, and no Geotech reports were done.. Testing Gauge Information: Manufacturer: Troxler Density Standard (DS): 2173 Remarks: Testing Completed at Bottom of Footing Legend for Llevatlon: PR = Proofroll SL = Springline SG = Subgrad'e BC = Basecourse TOP = Top of Pipe 1, 2, 3 = 1st, 2nd, 3rd Lift FL = Final Lift BG = Below Grade BOF = Bottom of Footing FG = Finished Grade Model: 3430 S/N Moisture Standard (MS): Test report shall not be reproduced, except in full, without the written approval of GFA Interna Environmental • Geotechnical • Construction Materials Testing • Special and Threshold li Florida's Leading Engineering Source www.teamgfa.com I 34784 609 02 • ral6d—WL %`V� 7 /2015 -p •VoIer, P.E :�,P.rofqpsional Engineer# ES675 z0 ......••. CG iOAiA L VA 305 0 _ _ -A9 p.m. 07-17-2015 212 521 NW Enterprise Drive • Port St. Lucie, Florida 34986 (772) 924-3575 • (772) 924-3580 (fax) 'ryTFRNA'rIG�Pv IN -PLACE DENSITY AND WATER CONTENT OF SOIL AND SOIL AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) - ASTM 6938 Project: Shoreline Mobile Home Repair - Various Projects Project ID: 14-1689.00 Address: Various _ _ _ Report ID:_ D-0006 Client: Shoreline Mobile Home Repair _ Date: 7/16/2015 Permit No: Field Tech: Daniel Dec_aro Test Mode: Direct Transmission Area Tested: 1335 Nettles Blvd., Jensen Beach - Footings (PERMIT N� _ 15050� 3,56,) Soil Description: Brown fine sand some rock Proctor / LBR ID: P-2 Max Density (PCF): 110.0 Opt Moisture (%): 10.0% Test Standard: - D 1557 Compaction Required (%): 95.0% Probe Depth (in) Elev Wet Density (PCF) Dry Density (PCF) Moist. (%) Compaction Location % Results Northwest 12 0-1 118.7 109.6 8.3% 99.6% Pass Southeast 12 0-1 118.8 109.1 8.9% 199.2% Pass Southwest 12 0-1 119.8 109.4 9.5% 99.6% Pass , JUL 17 .201 These tests and all previous tests do not certify the subgrade soils have a safe bearing capacity. No soil borings were completed, and no Geotech reports were done. Testing Gauge Information: Manufacturer: _. Troxler Model: —.- 3430 S/N: _ 34784 Density Standard (DS): 2173 -M Moisture Standard (MS): 609 Remarks: Testing Completed at Bottom of Footing - w Legeno Tor tievation: PR = Proofroll 1, 2, 3 = 1st, 2nd, 3rd Lift SL = Springline FL = Final Lift SG = Subgrade BG = Below Grade BC = Basecourse BOF = Bottom of Footing TOP = Top of Pipe FG = Finished Grade ._ �Ea r 5 ;sir Ronald W. Moler E.� W rest report shall not be reproduced, except In full, without the written approval of GFA International Environmental . Geotechnical • Construction Materials Testing • Special and Threshold Inspectionsivj�t-W& VP Florida's Leading Engineering Source ,���1��111111 www.teamgfa.com