Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 - _FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Corace Residence Builder Name: Street: Lot 1335 Nettles Island Permit Office: St. Lucie County City, State, Zip: Ft. Pierce , FL , Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1048.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1048.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 Is 5. Is this a worst case? No 10. Ceiling Types (1076.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1076.00 ft2 6. floor area above grade (ft2) 1076 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(185.0 sgft.) Description Area a. Sup: Main, Ret: Main, AH: Main 6 215.2 a. U-Factor: Sgl, U=0.29 185.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 30.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1076.0 sgft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 1076.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.172 Total Proposed IYlodified Loads: 19.27 PASS T tal St dard ference Loads: 26.71 �7�7 I hereby certify that the plans and speci cationt covqbd by Review of the plans and fc'CKE STD?. this calculation are in compliance with the Florida Energy specifications covered by this _4V Code. calculation indicates compliance y��i,, ',:.��0 ` QIi��iJf 1�1UNy ,t ,�I� f with the Florida Energy Code. rnr„`��., - ;;;•` „ PREPARED BY: Before construction is completed DATE: r this building will be inspected for compliance with Section 553.908 0I - a I hereby certify that this building, as designed, is in compliance Florida Statutes. cab with the Florida Energy Code. HtE'� OWNER/AGENT: ��.�"� pr,�,_. BUILDING OFFICIAL: DATE:. S- /S- / S DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist ;. 5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 . ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 72 The lower the EnergyPerformance Index, the more efficient the home. Lot 1335 Nettles Island, Ft. Pierce, FL, 1. New construction or existing New (From Plans) . 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1048.00 ft2 b. N/A R= ft2 3: Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1076.00 ft2 6. Conditioned floor area (ft2) 1076 b. N/A R= ft2 7. Windows"* Description Area c. R= 2 a. U-Factor: Sgl, U=0.29 185.00 ft2 11. Ducts a. Sup: Main, Ret: Main, AH: Main R ft2 6 215.2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 30.0 SEER:15.00 SHGC: d. N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: SHGC: a. Electric Heat Pump 30.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1076.00 ft2 a. Electric EF: 0.99 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: /2/� yti �� Date: Address of New Home: / 3 7 S a, �rrL �s ,g a City/FL Zip: NSA W 3Y937 ST,a-1*9 WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Co tact the EnergyGauge Hotline at (321) .638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact tote Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Co pliant SoftwareRE COPY PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit'Office: Jurisdiction: Family Type: New/Existing: Comment: Corace Residence User 1 St. Lucie County Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1076 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Lot 1335 Nettles Island St. Lucie Ft. Pierce, FL, CLIMATE v Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1076 8608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1076 8608 Yes 1 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value I rea Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 161 ft 0 1076 ft2 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Composition shingles 1165 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 107I ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 1076 ft2 0.11 Wood 5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 COPY Co7pliant Software Page 2 of 5 i. tea► WALLS • Adjacent Cavity Width Space Height Sheathing Framing Solar Below :a Ornt To Wall Type 1 N Exterior Concrete Block - Int Insul Main 5 42 8 336.0 ft2 0 0.75 0 2 E Exterior Concrete Block - Int Insul Main 5 38 8 304.0 ft2 0 0.75 0 3 S Exterior Concrete Block - Int Insul Main 5 23 8 184.0 ft2 0 0.75 0 4 W Exterior Concrete Block - Int Insul Main 5 28 8 224.0 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 S Wood Main None .46 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. • / Wall Overhang �/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.29 0.3 30.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds None 2 N 1 Metal Single (Tinted) Yes 0.29 0.3 35.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds None 3 E 2 Metal Single (Tinted) Yes 0.29 0.3 4.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds None 4 S 3 Metal Single (Tinted) Yes 0.29 0.3 15.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds None 5 S 3 Metal Single (Tinted) Yes 0.29 0.3 6.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds None 6 W 4 Metal Single (Tinted) Yes 0.29 0.3 60.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds None 7 W 4 Metal Single (Tinted) Yes 0.29 0.3 35.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1411.2 77.47 145.7 .365 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 9 30 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 30 kBtu/hr 900 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.99 40 gal 50 gal 120 deg None 5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER SYSTEM - FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS — Supply -- -- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Main 6 215.2 ft Main 53.8 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Venting Jan Feb Mar Apr May Jrl un Jul ri [X i Aug ri Sep Occtt Oct W N Nov Dec Dec Jun Jul E Aug Sep X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM` 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) PM 68 68 68 68 68 68 68 68 66 68 68 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 FU,7�,, �'Oupy 5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist, - Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Lot 1335 Nettles Island PERMIT #: Ft. Pierce, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft, Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawispaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. F 5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5