HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 -
_FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Corace Residence
Builder Name:
Street: Lot 1335 Nettles Island
Permit Office: St. Lucie County
City, State, Zip: Ft. Pierce , FL ,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (1048.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1048.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
Is
5. Is this a worst case? No
10. Ceiling Types (1076.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1076.00 ft2
6. floor area above grade (ft2) 1076
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(185.0 sgft.) Description Area
a. Sup: Main, Ret: Main, AH: Main
6 215.2
a. U-Factor: Sgl, U=0.29 185.00 ft2
SHGC: SHGC=0.30
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
30.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
30.0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.300
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1076.0 sgft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 1076.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.172 Total Proposed IYlodified Loads: 19.27
PASS
T tal St dard ference Loads: 26.71
�7�7
I hereby certify that the plans and speci cationt covqbd by
Review of the plans and
fc'CKE STD?.
this calculation are in compliance with the Florida Energy
specifications covered by this
_4V
Code.
calculation indicates compliance
y��i,, ',:.��0
`
QIi��iJf 1�1UNy ,t ,�I� f
with the Florida Energy Code.
rnr„`��., - ;;;•` „
PREPARED BY:
Before construction is completed
DATE: r
this building will be inspected for
compliance with Section 553.908
0I - a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
cab
with the Florida Energy Code.
HtE'�
OWNER/AGENT: ��.�"� pr,�,_.
BUILDING OFFICIAL:
DATE:. S- /S- / S
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist ;.
5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
. ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 72
The lower the EnergyPerformance Index, the more efficient the home.
Lot 1335 Nettles Island, Ft. Pierce, FL,
1. New construction or existing
New (From Plans) . 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=5.0
1048.00 ft2
b. N/A
R=
ft2
3: Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
2 d. N/A
R=
ft2
5. Is this a worst case?
No 10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1076.00 ft2
6. Conditioned floor area (ft2)
1076 b. N/A
R=
ft2
7. Windows"* Description
Area c.
R=
2
a. U-Factor: Sgl, U=0.29
185.00 ft2 11. Ducts
a. Sup: Main, Ret: Main, AH: Main
R ft2
6 215.2
SHGC: SHGC=0.30
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
30.0 SEER:15.00
SHGC:
d. N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
SHGC:
a. Electric Heat Pump
30.0
HSPF:9.00
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.300
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1076.00 ft2 a. Electric
EF: 0.99
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: /2/� yti �� Date:
Address of New Home: / 3 7 S a, �rrL �s ,g a City/FL Zip: NSA W
3Y937
ST,a-1*9
WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Co tact the EnergyGauge Hotline at (321)
.638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact tote Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Co pliant SoftwareRE COPY
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit'Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Corace Residence
User
1
St. Lucie County
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 1076
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
Lot 1335 Nettles Island
St. Lucie
Ft. Pierce,
FL,
CLIMATE
v Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1076 8608
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1076 8608 Yes 1
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
I rea
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 161 ft 0
1076
ft2
0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Composition shingles 1165 ft2 0 ft2 Medium
0.96
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
107I
ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Main 30 1076
ft2
0.11
Wood
5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1
COPY
Co7pliant Software Page 2 of 5
i. tea►
WALLS
•
Adjacent
Cavity Width
Space
Height Sheathing Framing Solar
Below
:a
Ornt
To Wall
Type
1
N
Exterior Concrete Block - Int Insul Main
5 42 8
336.0 ft2
0 0.75
0
2
E
Exterior Concrete Block - Int Insul Main
5 38 8
304.0 ft2
0 0.75
0
3
S
Exterior Concrete Block - Int Insul Main
5 23 8
184.0 ft2
0 0.75
0
4
W
Exterior Concrete Block - Int Insul Main
5 28 8
224.0 ft2
0 0.75
0
DOORS
#
Omt
Door Type Space
Storms
U Value Width
Height
Area
Ft In
Ft In
1
S
Wood Main
None
.46 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
• /
Wall
Overhang
�/
#
Ornt ID Frame
Panes NFRC
U-Factor SHGC
Area Depth Separation
Int Shade
Screening
1
N 1 Metal
Single (Tinted) Yes
0.29 0.3
30.0 ft2 1 ft 0 in 0 ft 0 in
Drapes/blinds
None
2
N 1 Metal
Single (Tinted) Yes
0.29 0.3
35.0 ft2 1 ft 0 in 0 ft 0 in
Drapes/blinds
None
3
E 2 Metal
Single (Tinted) Yes
0.29 0.3
4.0 ft2 1 ft 0 in 0 ft 0 in
Drapes/blinds
None
4
S 3 Metal
Single (Tinted) Yes
0.29 0.3
15.0 ft2 1 ft 0 in 0 ft 0 in
Drapes/blinds
None
5
S 3 Metal
Single (Tinted) Yes
0.29 0.3
6.0 ft2 1 ft 0 in 0 ft 0 in
Drapes/blinds
None
6
W 4 Metal
Single (Tinted) Yes
0.29 0.3
60.0 ft2 1 ft 0 in 0 ft 0 in
Drapes/blinds
None
7
W 4 Metal
Single (Tinted) Yes
0.29 0.3
35.0 ft2 1 ft 0 in 0 ft 0 in
Drapes/blinds
None
INFILTRATION
#
Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
.0005
1411.2 77.47 145.7 .365 9.8363
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump None
HSPF: 9
30 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
None
SEER: 15
30 kBtu/hr 900 cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap
Use SetPnt
Conservation
1
Electric
None Exterior
0.99 40 gal
50 gal 120 deg
None
5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 3 of 5
SOLAR HOT WATER SYSTEM
- FSEC
Collector
Storage
Cert #
Company Name
System Model #
Collector Model
#
Area
Volume
FEF
None
None
ftz
DUCTS
— Supply
--
-- Return ---
Air
CFM 25 CFM25
HVAC #
#
Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1
Main 6
215.2 ft
Main
53.8 ftz
Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Venting Jan
Feb
Mar
Apr
May
Jrl un
Jul
ri
[X
i Aug
ri
Sep Occtt Oct
W
N
Nov
Dec
Dec
Jun
Jul
E Aug
Sep
X�
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM`
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
PM
68
68
68
68
68
68
68
68
66
68
68
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
FU,7�,, �'Oupy
5/13/2015 3:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist,
- Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: Lot 1335 Nettles Island PERMIT #:
Ft. Pierce, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft, Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawispaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
F