Loading...
HomeMy WebLinkAboutRHVAC LoadsCorace Residence HVAC Load Calculations for Corace Lot 1335 Nettles Island Ft. Pierce, Florida RHVACftsmswnAL HVACoAD9 Prepared By: Residential Energy Calc's �. OF Wednesday, M 1�3, 01 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvc Residential Light•Commercial HVAC Loads „ Elite Software Development, Inc., Residential Energy Calc's Corace Residence . _ Port"Saint Lucie, FL 34 3 Pa e 2 Project Report. PGerieral Pro ect _Information 4 ,; Project Title: Corace Residence Designed By: QEA Assoc. Project Date: Wednesday, May 13, 2015 Client Name: Corace Client Address: Lot 1335 Nettles Island Client City: Ft. Pierce, Florida Company Name: Residential Energy Calc's Reference City: Fort Pierce, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 {yam,, ; �, � : . , . r Cilleck�Fl U�eS���.": u��k ' .., � ietk� J � a� an,Kr'ah�� ,. .. .' .7�, . . . . r �� �2 F;a.. '�rT Total Building Supply CFM: 898 CFM Per Square ft.: x 0.835 Square ft. of Room Area: 1,076 Square ft. Per Ton: 469 Volume (W) of Cond. Space: 9,298 - ,Builcim ,u Total Heating Required Including Ventilation Air: 20,327 Btuh 20.327 MBH Total Sensible Gain: 20,482 Btuh 74 % Total Latent Gain: 7,068 Btuh 26 , % Total Cooling Required Including Ventilation Air: 27,550 Btuh 2.30 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rhvay Residential ,& Light Commercial' HVAC Loads Elite Software Development, Inc.,. Residential Energy Catcs Corace Residence Port Saint Lucie, FL 34993 ': Page 3 Miscellaneous Repoit System $1 RheemOr EquivalentAt #h ° ®utdoor 3Outdoor�x�y�_�Outdoor"zfndoor� Intloor47} Gains i�J {�" r �4 f 4 J`P4 i _. i :.`1 ,£ 41 In ut'Data , .",._.Dry.Bulb1Net,BulbF...vReLHumy i4 Rel Hum;, pBulb, `Difference Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 buct Sizin 4In uts:'_ <N Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.'00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. .Maximum Height: 0 in. 0 in. Outside Air Data . `` Winter Summer Infiltration Specified: 0.450 AC/hr 0.230 AC/hr 70 CFM 36 CFM Infiltration Actual: 0.344 AC/hr 0.000 AC/hr Above Grade Volume: X 9,298 Cu.ft. X 9,298 Cu.ft. 3,196 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 53 CFM 0 CFM Total Building Ventilation: 45 CFM 45 CFM --System 1-- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.450 AC/hr (70 CFM), Construction: Average Summer Infiltration Specified: 0.230 AC/hr (36 CFM), Construction: Average C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM ,Rhvac Resttlenttal�8< Ught Gommesr�cialTHVAC`Loads� � y �� ' + } 4 �� r.���s��. �.z �{ � � �,, � �� Ehte�Software,�Developmentg Inc ! 1 J}SA�+ �x�fN•ffMv i' K4 Y�' `4''$W�. �,r�f eyYk* 3r` 4' � tR T 4 � $'Y'<Td wask� Residential EnergygCalcs Load Preview Report Net ft z Sen Lat Net Sen Sys Htg Sys Sys Act Duct Scope Ton /Ton Area Gain Gain Gain Loss CFMBuilding CFM CAM Size 2.30 469 I 1,076 20,482 7,068 27,550 20,3271 246 898, 898 System 1 2.30 4691,076, 20,482, 7 068 27,5501 20,327 246 898 10x17 Ventilation 742 1,868 2,610 ! 1,3851 Zone 1 1,076 19,741 1- 5,200, 24,941 18,942 : 246 898 ; 10x17 1-Living 170 4,504 600 5,104 4,046 53' 205 2-6 2-Foyer 65; 676- 0 676' 982 13' 31 1-4 3-Breakfast 110, 5,902. 1,000 6,902; 4,147' 54 269 3-6 4-l4tchen 182 2 782 1 000 , 3,782 1,471 19 127 2-5 5-Bath 2 56 227 0 227 660 9 10 1 6-Bedroom 2 156 : - 1 748: — 1,000 ; 2 748 2,449 i 32 80 ' 1-5 - 7-Bath 1 i 63 s 4771 oil477 , 823 I 11 22 1-4 8-Bedroom 1 182 2,4411 1,000 ; 3 441 ' 3 406 ; 44 ®- 111 2- 4 _. 9-Laundry -... - _ 64 --- - 9411 _ 600 1,541 667 � 9 ® 43 _ 1-4 _ 10-Hall 28 42: 0 42 291 4 2 1-4 CA ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Duct Size Preview Room or Source Minimum Maximum Rough. Designj SPI Dud Duct Htg Clg Act. Duct Dud Name Velocity Velocity Factor U100 Loss Velocity Length Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Living -- --- Built -In 450 ---- - _ - 750, 0.01 - 0.1. -- 521.8 - 53 - 2-Foyer Built -In ~, 450 7501 0.01 :. 0.1 352.E , 13 3-Breakfast Built In 450 750 001 ' 0.1 , - 455.9' 54 4-Kitchen Built -In 450 750' 0.01 0.1 464.2 19 &Bath 2 Built -In 450 750, 0.01 ' 0.11 118.3, 9 6-Bedroom 2 _ ....... - _ ... _ Built -In 450 750 ; 0.0 1 , 0.1 583.2 32 ..._.._. 7-Bath 1 Built -In 450 750 0.01 ' 0.1 ' 248.9 , 11 8-Bedroom 1 Built-in .. 450 750 . 0.01 : 0.1 636.2 ; 44 .. ..... ..... .._... 9-Laundry Built In _. 450 ._.... ._. 750 .. 0.01 , .. F 01 ..... ... 490.41 9 — - - 10-Hall Built-in 450: 750 0.01 0.1 22 4 Other Ducts in System 1 Supply Main Trunk Built-in 650 , 900, 0.003 0.11 760.7 246 205 - - 2-6 31 1-4 269 3-6 127: 2-5 10, 1-4 80' 1-5 22 1-4 - ----------------- 111 2-4 43 1-4 _—21-4 898 10x17 Summary System 1 .... _............. ..... ----- --------- .__....--------------- ---- _ .... .... ....... .-........_....... __........... ................. .............. _.------------ --...... ..... -......... .--- ---------- ------ __..---- _--------------- ---- -------- -----..._..------ ----- _......... ....... ........ - - Heating Flow: 246 Cooling Flow: 898 CA ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rhvac Residential 8 Light Commercial HVAC Loads Elite Software Development, Inc. Residential Energy Calc's .Corace Residence., Port Saint Lucie, FL 34983 Total Building Summp .. Loads - . . Com orient - Area Seri Lat ` Seri ToQ-1 Descry ;ton r ;Quart Loss Gain, Gain Gain IA-cb-o: Glazing -Single pane; operable window, clear, 117 3,541 0 5,211 5,211 metal frame with break, u-value 1.08, SHGC 0.75 IA-cm-o: Glazing -Single pane, operable window, clear, 76 2,703 0 4,386 4,386 metal frame no break, u-value 1.27, SHGC 0.75 11 D: Door -Wood - Solid Core 21 229 0 213 213 13A-5ocs: Wall -Block, board insulation only, R-5 board 1069 3,744 0 2,044 2,044 insulation, open core, siding finish 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1076 963 0 1,379 1,379 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation '22A-ph: Floor -Slab on grade, No edge insulation, no 161 6,122 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 17,302 0 13,233 13,233 People: 8 1,600 1,840 3,440 Equipment: 3,600 1,800 5,400 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 53, Summer CFM: 0 1,640 0 0 0 Ventilation: Winter CFM: 45, Summer CFM: 45 1,385 1,868 742 2,610 AED Excursion:_ 0 0 2,868 2,868 Total Building Load Totals: 20,327 7,068 20,482 27,550 Check,Fi Total Building Supply CFM: 898 CFM Per Square ft.: 0.835 Square ft. of Room Area: 1,076 Square ft. Per Ton: 469 Volume (ft3) of Cond. Space: 9,298 N"Ii - r: k ",... i g,� .. � i .� BUildm Loads . - k :.., � . � .: : ., .. per, +� .:. ' s a 1 r y,ny, r f1 3 � l „u rf 1 Total Heating Required Including Ventilation Air: 20,327 Btuh 20.327 MBH Total Sensible Gain: 20,482 Btuh 74 % Total Latent Gain: 7,068 Btuh 26 % Total Cooling Required Including Ventilation Air: 27,550 Btuh 2.30 Tons (Based On Sensible + Latent) ,Wtes A I Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rhvac Residential & Light Commercial'l-I Loads Elite Software Development, Inc. Residential Energy Calc's Corace Residence '.., P e 8 Detailed Room Loads - Room 1 - Living (Average Load Procedure) MneralA Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 170.0 sq.ft. Supply Air: 205 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 7.2 AC/hr Volume: 1,700.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 10 CFM Runout Air: 102 CFM Percent of Supply.: 5 % Runout Duct Size: 6 in. Actual Summer Vent.: 10 CFM Runout Air Velocity: 522 ft./min. Percent of Supply: 5 % Runout Air Velocity: 522 ft./min. Actual Winter Infil.: 10 CFM Actual Loss: 0.174 in.wg./l00 ft. Actual Summer Infil.: 0 CFM Item Sen Clg Lat Sen $Descn tion Qua t ty . Vale H M Loss HTM G_ ain Cain, SW-Wall-13A-5ocs 17 X 8 76 0.125 3.5 266 1.9 0 145 E -Wall-13A-5ocs 10 X 8 80 0.125 3.5 280 1.9 0 153 N -Wall-13A-5ocs 3 X 8 24 0.125 3.5 84 1.9 0 46 SW-GIs-lA-cb-o shgc-0.75 35%S 60 1.080 30.2 1,816 54.8 0 3,288 (4) UP-Ceil-16C-30 17 X 10 170 0.032 0.9 152 1.3 0 218 Floor-22A-ph 30 ft.. Per. 30 1.358 38.0 1,141 0.0 0 0 Subtotals for Structure: 3,739 0 3,850 Infil.: Win.: 10.0, Sum.: 0.0 240 1.279 307 0.000 0 0 AED Excursion: 654 Equipment: 600_ 0- Room Totals: _ _ _ 4,046 600 4,504 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rhvac - Residential & Light Commercial HVAC Loads .; Elite Software Development, Inc.: Residential Energy Calc's Corace Residence Port:Saint Lucie, FL 34983 .� Page 9 ,Detailed Room' ' Loads - Room .2 -) o er (Average Load Procedure Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 6.5 ft. Zone Number: 1 Area: 65.0 sq.ft. Supply Air: 31 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.8 AC/hr Volume: 650.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 31 CFM Percent of Supply.: 8 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 353 ft./min. Percent of Supply: 5 % Runout Air Velocity: 353 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.142 in.wg./100 ft. Actual Summer Infil.: 0 CFM ten "' Area hJ='. Htg Sen CIg Lat' S Descn tiara Quanti • ,.Value HTM Loss HTM Gain.. „Gain S -Wall-I3A-5ocs 6.5 X 10 38 0.125 3.5 133 1.9 0 73 S-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 S -GIs-IA-cm-o shgc-0.75 100%S 6 1.270 35.6 213 34.8 0 209 UP-Ceil-16C-30 10 X 6.5 65 0.032 0.9 58 1.3 0 83 Floor-22A-ph 7 ft..Per. 7 1.3_58 38.0 266 0.0_ _ _ 0 _ 0 Subtotals for Structure: 899- 0 578 Infil.: Win.: 2.7, Sum.: 0.0 65 1.277 83. 0.000 0 0 AED Excursion: 98 Room Totals: 982 0 676 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM „,Rhad Residential &Light CommercialrMVAC Residential Energy Calc's Loads e, Elite Software Development, Inc. Corace Residence_ Port Saint Lucie, FL 34983 Page. 16 Detailed, Room, Loads - Room 3 - Breakfast” (Avers . e. Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 110.0 sq.ft: Supply Air: 269' CFM Ceiling Height: 10.0 ft. Supply Air Changes: 14.6 AC/hr Volume: 1,100.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 10 CFM Runout Air: 90 CFM Percent of Supply.: 4 % Runout Duct Size: 6 in. Actual Summer Vent.: 13 CFM Runout Air Velocity: 456 ft./min. Percent of Supply: 5 % Runout Air Velocity: 456 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.134 in.wg./l00 ft. Actual Summer Infil.: 0 CFM °Item Area -U- Htg ' Sen Clg Lat Seh'. Descri � tion Quanti, - Value _ HTM Loss. _ HTM Gain . Gain-- W -Wall-I3A-5ocs 11 X 10 75 0.125 3.5 263 1.9 0 143 N -Wall-13A-5ocs 10 X 10 65 0.125 3.5 228 1.9 0 124 W -GIs-1A-cm-o shgc-0.75 11%S 35 1.270 35.6 1,245 84.5 0 2,957 N -GIs-1A-cm-o shgc-0.75100%S 35 1.270 35.6 1,245 34.9 0 1,220 UP-Ceil-16C-30 11 X 10 110 0.032 0.9 99 1.3 0 141 Floor- ,??, 21 ft._Per. 21 1.358 38.0 799 0.0 0 0 Subtotals for Structure: 3,879 0 4,585 Infil.: Win.: 8.7, Sum.: 0.0 210 1.276 268 0.000 0 0 AED Excursion: 857 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 0 _ _ Room Totals: 4,147 1,000 5,902 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rhvac esidential 8 Light -Commercial HVAC Loads Residential Energy Caic's ,06A Saint Lucie, FL 34983 . ` Elite Software Development, Inc.. Corace Residence Page 11 Detailed Room Loads - Room. 4- - Kitchen (Average Load Procedure) . Calculation Mode: Htg. & clg. occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 182.0 sq.ft. Supply Air: 127 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.2 AC/hr Volume: 1,456.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 3 CFM Runout Air: 63 CFM Percent of Supply.: 3 % Runout Duct Size: 5 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 464 ft./min. Percent of Supply: 5 % Runout Air Velocity: 464 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.178 in.wg./100 ft. Actual Summer Infil.: 0 CFM Itei7' Area =U- Htg Sen Clg I��"a"t Sen' Description Quanti , Value H1jM Loss FiTM Gain Gain, N -Wall-13A-5ocs 14 X 8 103 0.125 3.5 361 1.9 0 197 N -GIs-1A-cb-o shgc-0.75 100%S 9 1.080 30.2 272 32.0 0 288 UP-Ceil-16C-30 14 X 13 182 0.032 0.9 163 1.3 0 233 Floor-22A-ph 14 ft.. Per. 14 1.358 38.0 532 0.0 0 0 Subtotals for Structure: 1,328 0 718 Infil.: Win.: 4.7, Sum.: 0.0 112 1.277 143 0.000 0 0 AED Excursion: 404 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 1,200 Room Totals: 1,471 1,000 2,782 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM �;,Rh vac Residential & Light Commercial HVAC Loads Residential Energy Calc's Elite Software Development, Inc.: Cora`ce Residence, ;P6rt'"Saint Lucie,. FL 34993' Pa a 12' Detailed Room Loads - Room 5, -: Bath .2 (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 56.0 sq.ft. Supply Air: 10 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.4 AC/hr Volume: 448.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 10 CFM Percent of Supply.: 15 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 118 ft./min. Percent of Supply: 5 % Runout Air Velocity: 118 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.017 in.wg./100 ft. Actual Summer Infil.: 0 CFM ltem Area -U- Htg Sen Clg Lat Sen ®escri ; tion Quanti Valwe HTM Loss HTM Gain Gain, N -Wall-I3A-5ocs 8 X 8 64 0,125 3.5 224 1.9 0 122 UP-Cell-16C-30 8 X 7 56 0.032 0.9 50 1.3 0 72 Floor-22A-ph 8 ft..Per. 8 1.358 38.0 304 0.0 0 0 Subtotals for Structure: 578 0 194 Infil.: Win.: 2.7, Sum.: 0.0 64 1.281 82 0.000 0 0 AED Excursion: 33 Room Totals: 660 0 227 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rhvac Residential Light Corrimerc�al HVAC Loads " Elite Software D®velopment;,lnC. ILLEnergy Calds Resid' Corace Residence Port Saint Lucie, FL 34983 Pa a 13. Detailed. Room Loads - Room 6 = Bedroom.,2 (Average Load Procedure) (General,` ''' Lt Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 156.0 sq.ft. Supply Air: 80 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.8 AC/hr Volume: 1,248.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 6 CFM Runout Air: 80 CFM Percent of Supply.: 7 % Runout Duct Size: 5 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 583 ft./min. Percent of Supply: 5 % Runout Air Velocity: 583 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.280 in.wg./l00 ft. Actual Summer Infil.: 0 CFM Item Area -U' Htg Sen Clg Lat Sen` :'D se cription Q_ uanti Value; HTM Loss H�TM Gain .Gain. N -Wall-I3A-5ocs 13 X 8 89 0.125 3.5 312 1.9 0 170 E -Wall-13A-5ocs 12 X 8 96 0.125 3.5 336 1.9 0 184 N -GIs-IA-cb-o shgc-0.75 100%S 15 1.080 30.2 454 32.0 0 480 UP-Ceil-16C-30 13 X 12 156 0.032 0.9 140 1.3 0 200 Floor-22A-ph 25 ft.. Per. 25 1.358 38.0 951 0.0 0 0 Subtotals for Structure: 2,193 0 1,034 Infil.: Win.: 8.3, Sum.: 0.0 200 1.280 256 0.000 0 0 AED Excursion: 254 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600_ 0 Room Totals: _ 2,449 1,000 1,748 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rtivac Residential &Light Commercial HVAC loads_ ` ' Elde Software Development, Inc Residential Energy Calc`s Corace Residence port,Salnt Lucie, FL 34983 Detailed Room Loads - Room ,7 = Bath t (AVera a :Load Procedure) Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 9.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 63.0 sq.ft. Supply Air: 22 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.6 AC/hr Volume: 504.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 22 CFM Percent of Supply.: 9 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Ru.nout Air Velocity: 249 ft./min. Percent of Supply: 5 % Runout Air Velocity: 249 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.072 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item° 5� fay t� �kHtgClg,L F; K. �Gam Description �"4:���Quan_tit to Ualue,p�ry_Fi_TMz Lass HTMso sx�.Gam: .>,`� E -Wall-13A-5ocs 9 X 8 69 0.125 3.5 242 1.9 0 132 E -GIs-1A-cb-o shgc-0.75 41%S 3 1.080 30.2 91 65.0 0 195 UP-Ceil-16C-30 9 X 7 63 0.032 0.9 56 1.3 0 81 Floor-22A-ph 9 ft..Per. 9 1.358 38.0 342 0.0 0 0 Subtotals for Structure: 731 0 408 Infil.: Win.: 3.0, Sum.: 0.0 72 1.278 92 0.000 0 0 AED Excursion: 69 Room Totals: 823 0 477 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rhvac"Residential & Light Gommer`cial HVAC Loads L. Elite Software Development, Inc. Residential Er ergy Calc's I. Corac. Residence port:Saint Lucie FL 34983 ._ 1 , . :.,. Pa a 15 =Detailed Room Loads - Room 8 - Bedroom 1 (Average Load Procedure) Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 182.0 sq.ft. Supply Air: 111 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.6 AC/hr Volume: 1,456.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 8 CFM Runout Air: 56 CFM Percent of Supply.: 7 % Runout Duct Size: 4 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 636 ft./min. Percent of Supply: 5 % Runout Air Velocity: 636 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.455 in.wg./100 ft. Actual Summer Infil.: 0 CFM item"M ` Area -lmJ- " HtgfW�n Clg Lat Santity Value HTMs HTM Gain Gain.: E -Wall-I3A-5ocs 14 X 8 112 0.125 3.5 392 1.9 0 214 S -Wall-13A-5ocs 13 X 8 74 0.125 3.5 259 1.9 0 142 W -Wall-13A-5ocs 5 X 8 40 0.125 3.5 140 1.9 0 77 S-Gls-lA-cb-o shgc-0.75 1 00%S 30 1.080 30.2 908 32.0 0 960 (2) UP-Ceil-16C-3014 X 13 182 0.032 0.9 163 1.3 0 233 Floor-22A-ph 32 ft.. Per. 32 1.358 38.0 1,217 0.0 0 0 Subtotals for Structure: 3,079 0 1,626 Infil.: Win.: 10.6, Sum.: 0.0 256 1.277 327 0.000 0 0 AED Excursion: 355 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment:' _ _ 600 0 Room Totals: 3,406 1,000 2,441 C:1... 1Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM Rh4aa - esidential $ Light Commercial NVAC Loads Residential Energy Calc's Elite Software Development,, Inc. Corace Residence Port•Saint Lucie, ,FL 34983 , Pa `e,16: [tailed Room. Loads -.Room 9 - Laundry (Average Load Procedure) n Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 8.0 A. Zone Number: 1 Area: 64.0 sq.ft. Supply Air: 43 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.0 AC/hr Volume: 512.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 43 CFM Percent of Supply.: 4 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 490 ft./min. Percent of Supply: 5 % Runout Air Velocity: 490 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.272 in.wg./100 ft. Actual Summer Infil.: 0 CFM lltei Desert tion Area 1�1-, Quanti _ . Value Htg 3en ,, HTM Loss Clg HTtM Lat Gain Sen' Gain E -Wall-13A-5ocs 8 X 8 64 0.125 3.5 224 1.9 0 122 UP-Ceil-16C-30 8 X 8 64 0.032 0.9 57 1.3 0 82 Floor-22A-ph 8 ft..Per. 8 1.358 38.0 304 0.0 0 0 Subtotals for Structure: 585 0 204 Infil.: Win.: 2.7, Sum.: 0.0 64 1.281 82 0.000 0 0 AED Excursion: 137 Equipment: 600 600 Room Totals: 667 600 941 C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM ;ihva6Residential 916 Light Commerclal.HVAC Loads Elite`Software,Development, Inc. Residential Energy Calc's - , Corace Residence _ "Pori Sainfl-ucie, FL. 34983 Page 17 Detailed Room Loads,.- Room: 10 - Hall (Average Load Procedure) Gen'erat. �' Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 7.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 1 Area: 28.0 sq.ft. Supply Air: 2 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 0.5 AC/hr Volume: 224.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 2 CFM Percent of Supply.: 36 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 22 ft./min. Percent of Supply: 5 % Runout Air Velocity: 22 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.001 in.wg./l00 ft. Actual Summer Infil.: 0 CFM tterm Area -U- Htg Sen Clg tat Sem 3,Descri tion Quantit , Valu_e HTM Loss HTM ain UP-Ceil-16C-30 7 X 4 28 0.032 0.9 25 1.3 0 36 Floor-22A-ph 7 ft..Per. 7 1.358 38.0 266 0.0 0 0 Subtotals for Structure: 291 0 36 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 AED Excursion: 6 Room Totals _ 291 0 42 Q\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM `lZhvac esidential & Light Commercial HVAC Loads_ Elite Software Development, Inc: Residential Energy calc's '. Corace Residence Port Saint,Lude, FL, 34983 „ . Page, 18 System 9 Room Load Summary Area Sens Htg Duet Duct Sens Lat CIg44Sys: fRoom� ---Zone 1-- 1 Living 170 4,046 53 2-6 522 4,504 600 205 205 2 Foyer 65 982 13 1-4 353 676 0 31 31 3 Breakfast 110 4,147 54 3-6 456 5,902 1,000 269 269 4 Kitchen 182 1,471 19 2-5 464 2,782 1,000 127 127 5 Bath 2 56 660 9 1-4 118 227 0 10 10 6 Bedroom 2 156 2,449 32 1-5 583 1,748 1,000 80 80 7 Bath 1 63 823 11 1-4 249 477 0 22 22 8 Bedroom 1 182 3,406 44 2-4 636 2,441 1,000 111 111 9 Laundry 64 667 9 1-4 490 941 600 43 43 10 Hall 28 291 4 1-4 22 42 0 2 2 1,385 _ _ 742 1,868 _ _ _Ventilation System 1 total _ 1,076 20,327 246 20,482 7,068 898 898 System 1 Main Trunk Size: 10x17 in. Velocity: 761 ft./min Loss per 100 ft.: 0.097 in.wg - ti Net Required: 2.30 74% / 26% 20,482 7,068 27,550 Actual: 2.50 73%/27% 21,900 8,100 30,000 Equipment Heating System Cooling System Type: Two Speed Heat Pump Standard Air Conditioner Model: RSBH17A07J RPQL030JEZ Indoor Model: RHLLHM3617JA Brand: PRESTIGE PRESTIGE, Description: HEAT PUMP HSPF 9.0 15 SEER Efficiency: Hi: 9 / Lo: 0 HSPF 15 SEER Sound: 0 0 Capacity: 30,000 Btuh 30,000 Btuh Sensible Capacity: n/a 21,900 Btuh Latent Capacity: n/a 8,100 Btuh C:\ ...\Corace Residence.rh9 Wednesday, May 13, 2015, 3:01 PM