Loading...
HomeMy WebLinkAbout18-2189 BNDY C3D 2020-FINALSS.pdf4.83N 50°10'40" W 76.62'(P&M)(RAD) N 22°08'11" W 122.92'(P&M)(NR)116.03'(P&M)134.88'(M)N 89°59'38" EN 81°16'31" W77.20'(P&M)60.85'(M)38.85'(M)PLATTED SURVEYCLOSURE LINEMHWLINDIAN RIVERALLWOOD RIVERFRONT(PLAT BOOK 32, PAGE 2)LOT 4LOT 3LOT 5"VC"ISLAND DUNES COVETRACT "A"60.00'(P)S 89°59'38" W 186.07'(P) 185.91'(M)S 00°00'22" W17.31'(P)FND 5/8"R&C LB 4286(VACANT)(OCCUPIED)FFE= 7.79FND 5/8"R&C LB 4286FND 4"X4" CMPRM 3859F N D 5 / 8 " I R N O I D FND 5/8" R&CLB 6018FND 5/8"R&C ILL35'27.01'(P)EOW39.53'(P)"FC""VC""FC"FND 5/8" IR NO IDE 0.16'(RP)NOT IN(PC)FND M&DPCP LB 428610' UE10' U E LOT 3(OCCUPIED)FFE= 9.62LOT 1&2(OCCUPIED)FFE= 7.44EXISTING BLDGEXISTING BLDGBST4.494.394.294.99"AE 4"4.684. 5 4.44. 5 5.3"AE 4"5.25.4 5.44.65.24.86.3CONSERVATION AREAMHWL5.24.55.04. 7 5.14. 8-0.33-0.33-0.33-0.33I C V RP Z 4. 5 4. 5 6.19CO2.02.01.71.74.0 4.1TOBTOB3.6 3.4EOW-1.0C1CURVE CHARTC1R= 60.00'(P&M)Δ= 37°06'32"L= 38.86'WOODSEAWALLS 2.75'L1L2LINE CHARTL1S 28°11'16" E 45.40'(M)L2S 13°03'07" E 36.52'(M)10.85'8.25'10.57'10.55'15' PAEBMSET M&TT NO IDEL= 4.36 NAVDMHWL FROMTIDE INTERPOLATION POINTSID: 949COUNTY: ST LUCIEQUAD NAME: EDENQUAD NUMBER: 2702MEAN HIGH: -0.33'(50' R/W)"AE 4""X""AE 6"APPROXIMATE FLOOD ZONEDELINEATION LINE"X"APPROXIMATE FLOOD ZONEDELINEATION LINEFND 5/8" R&CLB 82066"8"/12'4"16"/12'4"3.016"/12'18"/15'15"/10'13"/13'13"/10'14"8"15"/12'12"/12'15"/12'MANGROVES12"/24'10"/18'N 04°09'34" E 73.31'(P&M)PLATTED APPROXIMATEEASTERLY MHWL4.6"AE 4""AE 6"25.00'14.67'3.00'39.33'4.71'22.33'15.67'14.33'55.67'18.34'15.10'19.73' 15.49'36.38'0.67' X 1.35' (TYP)63.74'3 STORY CBSSINGLE FAMILYRESIDENCEFFE= 6.58POOL12.67'12.67'42.0'42.0'PAVERDECK60.08'PAVERDRIVESTAIRSCOVEREDTERRACECOVEREDTERRACE14.67'36.17'10.17'13.0'12.83'12.83'11.83'10.0'51.0'28.06'16.10'4.77'7.33'14.0'CECSCSGMCS3'11.33'4.94'5.24'6.29'3.44'PAVERDRIVE17 .0 ' 15 .65 '11.75'33.82'18.42'7.33'6.33'6.06.176.176.06.06.0'5.85.76.36.36.78'6.53'BLOCK WALL0.67' WIDESTATE OF FLORIDA (PSM)#6285PROFESSIONAL SURVEYOR AND MAPPERROBERT F. KEMERSON=POSTED SIGN=LIGHT POLE=WOOD POWER POLE=WIRE PULL BOX=BACK-FLOW PREVENTOR=WATER METER=WATER VALVE=FIRE HYDRANT=CLEAN-OUT=CURB INLET TYPE 6=SANITARY MANHOLE=DRAINAGE MANHOLE= YARD DRAIN= IRRIGATION VALVE= IRRIGATION CONTROL VALVEL E G E N D=BELLSOUTH TELEPHONE RISER=BELLSOUTH TELEPHONE MANHOLE=GREASE TRAP=TRAFFIC SIGNAL BOX=DOUBLE DETECTOR CHECK VALVE=FIRE DEPARTMENT CONECTOR=FIRE INDICATOR POST=ELECTRIC METER=GAS VALVE=CATCH BASIN=MITERED END SECTION=CONCRETE POWER POLE= ELECTRIC SERVICE BOX= AIR RELEASE VALVE= SANITARY VALVESHEET:1 OF 1JOB NUMBER:18-2189BOUNDARY & TOPOGRAPHIC SURVEY THE HRIBAR'S PREPARED FORAPPROVED BY:R. KEMERSONFIELD BOOK/PAGESPLANSDRAWN BY:G SANTOIEMMASCALE:1" = 20'DATE:12/19/18GJS 04-13-20 GJS 06-16-21 BY:DATE: REVISE PLOT PLAN ELEVATIONS REVISE RETAINING WALL REVISIONS Web Site: www.velconfl.com PORT ST. LUCIE, FLORIDA 34986 590 NW PEACOCK BLVD, SUITE 8 VELCON ENGINEERING PHONE (772) 879-0477 CERTIFICATE OF AUTHORIZATION NO. LB 8206A B B R E V I A T I O N S L E G E N DILLEGIBLEILLP PLATPOINT OF COMPOUND CURVATUREPRESSURE CLEAN OUT (SANITARY) PERMANENT CONTROL POINTPARKER KALON NAIL AND DISKPARKER KALON NAIL AND TIN TABPOINT OF CURVATUREPAGEPARKER KALON NAILPOINT OF INTERSECTIONPLASTIC FENCEPLAT BOOKPC PCC PCO PCP PG PK PI PK&D PK/TT PF PB NATIONAL GEODETIC VERTICAL DATUMNORTH AMERICAN VERTICAL DATUMPROPERTY LINEOVERHEAD ELECTRICOVERHEAD UTILITYOVERHEAD EASEMENTOFFSETNATIONAL GEODETIC SURVEYNAIL AND DISKNAILMINIMUMMITERED ENDOFFICIAL RECORDNON-APPLICABLEOFFICIAL RECORD BOOKP/L OHE OHU OE O/S NGVD NGSNAVD N&D N MIN MIT OR NA ORB MEAN HIGH WATER LINEMAN HOLEMEASURED MITERED END SECTIONMEASURED LICENSED SURVEYORLIGHT POLELICENSED BUSINESSLENGTH IRON PIPEIRON RODINVERT MHWL MH MEAS MES M LS LP LB L IP IR INV INTERSECTIONINT APPROXIMATEAPRXBMBENCHMARK DRAINAGE & UTILITY EASEMENTCONCRETE BLOCK STRUCTURE ELECTRIC SERVICE BOXELECTRIC METERENCROACHMENTEDGE OF WATEREDGE OF PAVEMENTELEVATIONDRAINAGE EASEMENTDUCTILE IRON PIPEDRAINAGE MANHOLEELEVATIONESB EM ENCEOW EP ELEV D.E. EL DMH DUE DIP CMCONCRETE MONUMENTCORRUGATED METAL PIPEDELTA ANGLECORRUGATED PLASTIC PIPE CORNER CONCRETE POWER POLEDRAIN FIELD CONCRETECLEAN OUTCOVEREDCONSTRUCTIONDEED INFORMATIONCONCRETE SLABCOVERED ENTRYCOVERED PORCHCMP COV D/F D ΔCORCPPCONC COCONST CPPIPECSCECOVPCULPEPPER & TERPENINGCENTERLINE CUT OUTCABLE TELEVISION BOXBARBED WIREBACK OF WALKBEARINGCHAIN LINK FENCECATCH BASIN CURVE INFORMATIONCOASTAL BARRIER CALCULATEDBACK OF CURBCL C/OCATVC&T BRGCBRSC1BW CBCBSCLF BOWC BOCBUFFER EASEMENTASPHALTBUILDING BACK FLOW PREVENTORBLOCK BFPBLDGASPBEBLKESMT EXT EX FNCFFE FH FND FPL HGW EASEMENTEXISTINGEXTENDEDFENCEFINISHED FLOOR ELEVATIONFIRE HYDRANT FOUNDFLORIDA POWER & LIGHTHOG WIRE A/CANCAPACAIR CONDITIONINGACRE ANCHOR ANCHOR POLE HYD ICV HYDRANTIRRIGATION CONTROL VALVEHEADWALL HW TELEPHONE RISERTRWOOD POWER POLEUNDER CONSTRUCTIONTRAFFIC SIGNAL BOXWP WS WPP WM WLWD "VC " U.E. UP WATER SERVICEWELL POINTWATER METERWOODWATER LINEVALLEY CURBUTILITY EASEMENTUTILITY POLEU/C TYPTWP TSB TT TRANS TYPICALTOWNSHIPTIN TABTRANSFORMERPOWER POLEPROPOSEDPSM PP POB POC PLS PROP PRO PRM PRC PROFESSIONAL SURVEYOR & MAPPERPOINT OF COMMENCEMENTPOINT OF BEGINNINGPRORATED DISTANCEPROFESSIONAL LAND SURVEYORPERMANENT REFERENCE MONUMENTPOINT OF REVERSE CURVATURERANGESECTIONRIGHT-OF-WAYROD AND CAPRADIUSRADIUS POINTSIDEWALKSQUARE FEETQUADP.U.E. SEC RGE R/W R&C RCP RP RLS S/W SMHSBT SF STANDARDSANITARY VALVESWALESTORYTAX MAPTOE OF SLOPETOP OF BANKTRAVERSE POINTSTDSV SWL STUTM TOB TOE TP SLP QUADRANTPRIVATE UTILITY EASEMENTREINFORCED CONCRETE PIPEREGISTERED LAND SURVEYORSANITARY SEWER MANHOLESOUTHERN BELL TELEPHONESTREET LIGHT SUPPORT POLEP/W PAVER WALKPTPOINT OF TANGENCYSHPSHIP SPIKE OR BOLT(NR)NON-RADIALRRSRAILROAD SPIKEIP&PIRON PIPE & PLUGCURB INLETCIELECTRICAL CONTROL PANELECPDC"D" CURBDROP INLETDI"F" CURB"FC"FACE OF WALKFOWFACE OF CURBFOCGREEN AREAGAGRINDERGRDELECELECTRICHCHEADER CURBLINE INFORMATIONL1M&TTMAGNETIC NAIL & TIN TABMONITORING WELLMWIWIRRIGATION WELLPRESERVATION AREA EASEMENTPAEVLTVAULTALUMINUMALDIAMETERDIAFIRE DEPARTMENT CONNECTIONFDCNTSNOT TO SCALELOCATIONLOCRRRAILROADTOP OF ASPHALTTAIDENTIFICATIONIDSANITARY SEWERS.S.FLORIDA EAST COAST RAILROADFECRRTELEPHONE MANHOLETMHGMHGAS MANHOLEGROUNDGNDMNMAGNETIC NAILP/C PROPERTY CORNERBRICK PAVERSBPSPCSTATE PLANE COORDINATESUNDER WATERUW M&DEDGE OF CONCRETEECURUTILITY RISERLAKE MAINTENANCE EASEMENTLMEHDPEHIGH DENSITY POLYETHYLENESLCRST LUCIE COUNTY RECORDSMETES AND BOUNDSM&BIRRIGATION CONTROL VALVEICVIVIRRIGATION VALVERSEPTIC TANKST PARKINGPRKGHCPHANDI-CAPWV WATER VALVERADIAL(RAD)IRRIRRIGATIONMN&DMAGNETIC NAIL & DISKYRDMES& SURVEYING, LLCADDRESS: 112 ISLAND DUNES COVE FORT PIERCE, FLNOTES:SUBJECT TO ANY APPLICABLE EASEMENTS, RIGHTS-OF-WAY, OR OTHERRESTRICTIONS OF RECORD.A SEARCH OF THE PUBLIC RECORDS HAS NOT BEEN MADE BY THIS OFFICE.ELEVATIONS ARE IN FEET AND RELATED TO NGS BENCHMARK "94 77 A O7 FLDT",PUBLISHED ELEVATION = 2.28 (FEET) NAVD 1988.BEARINGS SHOWN HEREON ARE BASED UPON AN PLATTED MERIDIAN, ALONG THECENTERLINE OF ISLAND DUNES COVE, HAVING AN PLATTED BEARING OFS 89°59'38" W. ALL OTHER BEARINGS ARE RELATIVE THERETO.PROPERTY LIES IN F.I.R.M. ZONE "X AND AE 4", AS SHOWN ON MAP NUMBER12111C0311 K, DATED 2/19/20. FLOOD ZONES ARE APPROXIMATE AS SCALED FROMFLOOD INSURANCE RATE MAPS AND ARE ONLY AS ACCURATE OF THE MAP SCALE OF1" = 500'.IN ACCORDANCE WITH CHAPTER 5J-17.051, ADDITIONS OR DELETIONS TO SURVEYMAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY, IS PROHIBITED WITHOUTWRITTEN CONSENT OF THE SIGNING PARTY.THERE MAY BE ADDITIONAL RESTRICTIONS THAT ARE NOT SHOWN ON THISSURVEY, THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY,FLORIDA.NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND RAISED SEAL OF A FLORIDALICENSED SURVEYOR AND MAPPER.THE EXPECTED USE OF THE SURVEY AND MAP IS RESIDENTIAL.ALL DISTANCES AND ELEVATIONS SHOWN ARE IN ACCORD WITH THE UNITEDSTATES STANDARD USING FEET.ALL DIRECTIONAL MEASUREMENTS SHOWN ARE IN THE FORMAT OF DEGREES,MINUTES AND SECONDS.LEGAL DESCRIPTION FROM WARRANTY DEED RECORDED IN OFFICIAL RECORD BOOK4146, PAGE 2853, ST LUCIE COUNTY PUBLIC RECORDS.PUBLIC WATER & SEWER AVAILABLE.LOT CONTAINS 13,474 SQUARE FEET TO THE MHWL ELEVATION -0.33' AND 16,124SQUARE FEET TO PLATTED APPROXIMATE EASTERLY MHWL.BOUNDARY & TOPOGRAPHIC SURVEY FIELD DATE: 12/18/18.UPDATE SURVEY FIELD DATE: 09-19-19.TREE LOCATION FIELD DATE: 10-22-19.FINAL SURVEY FIELD DATE: 2/01/22.CERTIFIED TO: GARY HRIBAR & SHERILYN D HRIBAR.LEGAL DESCRIPTION:LOT 4, LAS TORTUGAS AT HUTCHINSON ISLAND, ACCORDING TO THE MAP OR PLATTHEREOF AS RECORDED IN PLAT BOOK 44, PAGE 5 AND 5A, PUBLIC RECORDS OF ST.LUCIE COUNTY, FLORIDA.MAGNETIC NAIL & DISKRESOURCE SYSTEMBK 09-24-19 UPDATE SURVEY AND MHWL= SEAGRAPE CLUSTER= PALM TREE - INCHES/TRUNK HEIGHT= PINE TREETREE LEGEND= UNKNOWN TREE= GUMBO LIMBO TREEBK 10-25-19 ADD TREES TO SURVEY= PROPOSED ELEVATION= DRAINAGE FLOWBK 11-19-19 ADD 2ND RETAINING WALL TO PLOT PLAN BK 03-18-20 UPDATE FLOOD ZONE INFORMATION BK 08-11-20 FORMBOARD SC 2-07-22 FINAL SURVEY6.0= SPOT ELEVATION5. 0N:\Projects\2018\18-2189 Hribar - Island Dunes\18-2189 BNDY C3D 2020.dwg, 2/8/2022 9:29:31 AM, AutoCAD PDF (General Documentation).pc3