Loading...
HomeMy WebLinkAboutAPPROVED, Design Pressure ReportProperty Information Owner:KUNKEL, JOSEPH /HICKS, JESSICA Address:11505 PALOMINO DR. FORT PIERCE, FL. 34987 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:41 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 35.75 36.25 7 37.8 -50.6 2 End 35.75 36.25 7 37.8 -50.6 3 Int 35.75 36.25 7 37.8 -41.0 4 Int 35.75 36.25 7 37.8 -41.0 5 Int 35.75 61 7 36.8 -40.0 6 Int 35.75 61 7 36.8 -40.0 7 Int 35.75 61 7 36.8 -40.0 8 Int 35.5 61 7 36.8 -40.0 9 Int 35.5 61 7 36.8 -40.0 10 End 35.5 36.75 7 37.8 -50.6 11 Int 35.25 36.25 7 37.8 -41.0 12 End 35.25 36.25 7 37.8 -50.6 13 Int 35.75 36.25 7 37.8 -41.0 14 Int 35.75 36.25 7 37.8 -41.0 15 End 25 24 7 37.8 -50.6 16 Int 25 24 7 37.8 -41.0 17 Int 35.75 36.25 7 37.8 -41.0 18 Int 35.75 36.25 7 37.8 -41.0 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1