HomeMy WebLinkAboutEnergy Efficiency Code RECEII,'..D JUN^ 6 2 Ir
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Standard Pacific RB Wentworth Lot 19 Builder Name: Standard Pacific Homes
Street: `31 D® NA.) (Zd90 Permit Office: Port St Lucie
City,State,Zip: Port St Lucie,FL, Permit Number:
Owner: Standard Pacific Homes Jurisdiction: 461100
I Design Location: FL,Fort Pierce
1. Ncw construction or existing New(From Plans) 9. Wall Types(6556.9 sqft.) Insulation Area
2. dingle family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 6023.40 ftz
b.Frame-Wood,Adjacent R=11.0 373.45 ftz
3. Number of units,if multiple family 1 c.Concrete Block-Int Insul,Adjacent R=4.1 160.05 ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types (3300.0 sqft.) Insulation Area
a.Under Attic(Vented) R=38.0 3300.00 ftz
6. Conditioned floor area above grade(ftz) 6155 b.N/A R= 'ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(1530.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:AC 1 Club Room Living 6 175
a. U-Factor: Sgl,U=1.07 734.31 ftz b.Sup: Attic,Ret:AC 2 Family Kitchen Dining Foy, 6 150
SHGC: SHGC=0.30 c.Sup:Attic,Ret:Attic,AH:Attic 6 275
b. U-Factor: Sgl,U=1.00 389.76 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:14.00
b.Central Unit 45.5 SEER:14.00
c. U-Factor: Sgl,U=1.05 384.00 ftz c.Central Unit 41.0 SEER:14.00
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: other(see details) 22.67 ftz a.Electric Heat Pump 29.6 HSPF:8.00
SHGC: other(see details) b.Electric Heat Pump 45.0 HSPF:8.00
Area Weighted Average Overhang Depth: 6.934 ft. c.Electric Heat Pump 38.5 HSPF:8.00
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (3300.0 sqft.) Insulation Area a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 3300.00 ftz b. Conservation features EF:0.910
b.N/A R= ftz None
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.249 Total Proposed Modified Loads: 82.60 PASS
Total Standard Reference Loads: 109.96
I hereby certify that the plans and specifications covered by Review of the plans and O OBE s���
this calculation are in compliance with the Florida Energy specifications covered by this R RZp
Code. calculation indicates compliance
Digitally signed by Chris Wildroudt
Chris DN:cn=Chris Wildroudt,pus, with the Florida Energy Code.
-Engineered Air,LLC,ou-New
PREPARED BY: x g - Before construction is completed
:bnstroctlort5atesartd-E�tglneering,
DATE: \A/� tr/� email chisw(a�enolneeredalrllacom this building will be inspected for
�"t Date 2015.05.15'1153.57-04'00' compliance with Section 553.908
St
atutes.tatutes.
I hereby certify that this building, as designed, is in compliance Florida '�, 5
All
with the Florida Energy Code. GOD WE
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with 403.2.2.1.1. -
- Compliance requires completion of a Florida Air Barrier and Insulation.Inspection Checklist
-Heat sys#1 may be undersized.Size of 29.6 was increased to 36.8 for simulation: Please review the Manual J8 report.-Heat sys
#2 may be undersized.Size of 45.0 was increased to 50.3 for simulation. Please review the Manual J8 report.-Cool sys#2 may be
undersized.Size of 45.5 was increased to 48.0 for simulation. Please review the Manual J8 report.
5/15/2015 11:52 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7
V
PROJECT
Title: Standard Pacific RB Wentwor Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 6155 Lot# 19
Owner: Standard Pacific Homes Total Stories: 2 Block/SubDivision: Riverbend
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Standard Pacific Homes Rotate Angle: 225 Street:
Permit Office: Port St Lucie Cross Ventilation: County: St.Lucie
Jurisdiction: 461100 Whole House Fan: City,State,Zip: Port St Lucie,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low
BLOCKS
Number Name Area Volume
1 Block1 1465 15631.5498
2 Block2 1835 26142.3281
3 Block3 2855 26637.1503
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 AC 1 Club Room Li 1465 15631.55 No 3 1 1 Yes Yes Yes
2 AC 2 Family Kitche 1835 26142.3275 Yes 3 0 1 Yes Yes Yes
3 AC 3 Second Floor 2855 26637.15 No 4 3 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio AC 1 Club Room 173 ft 0 1465 ft2 ____ 0 0 1
2Slab-On-Grade Edge Insulatio AC 2 Family Kitch 183 ft 0 1835 ft2 _-__ 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Metal 3691 ft2 0 ft2 Medium 0.6 No 0.9 - No 1 26.6
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 3300 ft2 N N
5/15/2015 11:52 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7
T
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) AC 2 Family Kitch 38 697 ftz 0.11 Wood
2 Under Attic(Vented) AC 3 Second Flo 38 2603 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
t To Wall Type R Vag�P Et In Ft In Area R-N/alue Fraction Ahsor^Grad °
1 E=>NW Exterior Concrete Block-Int InsAIC 1 Club Ro 4.1 9 0 10.67 0 96.02999 0.4 0 0.4 0
2 S=>NE Exterior Concrete Block-Int InsAC 1 Club Ro 4.1 56 0 10.67 0 597.5200 0.4 0 0.4 0
3 W=>SE Exterior Concrete Block-Int InsAIC 1 Club Ro 4.1 22 0 10.67 0 234.7400 0.4 0 0.4 0
4 W=>SE Exterior Concrete Block-Int InsAIC 1 Club Ro 4.1 29.5 0 10.67 0 314.7650 0.4 0 0.4 0
5 N=>SW Exterior Concrete Block-Int InsAIC 1 Club Ro 4.1 14.5 0 10.67 0 154.7149 0.4 0 0.4 0
6 N=>SW Exterior Concrete Block-Int InsAIC 1 Club Ro 4.1 14 0 10.67 0 149.3800 0.4 0 0.4 0
7 E=>NW Garage Frame-Wood AC 1 Club Ro 11 16 0 10.67 0 170.7200 0.4 0 0.4 0
8 E=>NW Garage Concrete Block-Int Ins=1 Club Ro 4.1 6 0 10.67 0 64.02000 0.4 0 0.4 0
9 S=>NE Garage Frame-Wood AC 1 Club Ro 11 6 0 10.67 0 64.02000 0.4 0 0.4 0
10 E=>NW Exterior Concrete Block-Int InsiAC 2 Family 4.1 12 0 10.67 0 128.0400 0.4 0 0.4 0
11 E=>NW Exterior Concrete Block-Int InstAC 2 Family 4.1 12 0 10.67 0 128.0400 0.4 0 0.4 0
12 E=>NW Exterior Concrete Block-Int Ins&C 2 Family 4.1 9 0 10.67 0 96.02999 0.4 0 0.4 0
13 S=>NE Exterior Concrete Block-Int InsiAC 2 Family 4.1 18 0 21.67 0 390.0599 0.4 0 0.4 0
14 W=>SE Exterior Concrete Block-Int InsAC 2 Family 4.1 30 0 10.67 0 320.1000 0.4 0 0.4 0
15 W=>SE Exterior Concrete Block-Int InstAC 2 Family 4.1 22.5 0 21.67 0 487.5750 0.4 0 0.4 0
16 N=>SW Exterior Concrete Block-Int InsidC 2 Family 4.1 19 0 21.67 0 411.7300 0.4 0 0.4 0
17 N=>SW Exterior Concrete Block-Int InsiAC 2 Family 4.1 38.5 0 10.67 0 410.7950 0.4 0 0.4 0
18 E=>NW Garage Concrete Block-Int InstAC 2 Family 4.1 9 0 10.67 0 96.02999 0.4 0 0.4 0
19 E=>NW Garage Frame-Wood AC 2 Family 11 13 0 10.67 0 138.7100 0.4 0 0.4 0
_20 E=>NW Exterior Concrete Block-Int InsAC 3 Second 4.1 70 0 9.33 0 653.0999 0.4 0 0.4 0
_21 S=>NE Exterior Concrete Block-Int InsAC 3 Second 4.1 59 0 9.33 0 550.4699 0.4 0 0.4 0
_22 W=>SE Exterior Concrete Block-Int InsAC 3 Second 4.1 22 0 9.33 0 205.2599 0.4 0 0.4 0
_23 W=>SE Exterior Concrete Block-Int InsAC 3 Second 4.1 29.5 0 9.33 0 275.2349 0.4 0 0.4 0
_24 N=>SW Exterior Concrete Block-Int InsAC 3 Second 4.1 45 0 9.33 0 419.8500 0.4 0 0.4 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>NW Insulated AC 1 Club Ro None 0.4 2.67 0 8 0 21.36000
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 225 degrees).
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 E=>NW 1 Metal Low-E Single Yes 1.05 0.28 48 ft' 7 ft 0 in 2.67 ft 0 i None None
2 E=>NW 1 Metal Low-E Single Yes 1 0.32 9 ft2 7 ft 0 in 1 ft 0 in None None
3 S=>NE 2 Metal Low-E Single Yes 1 0.32 13.30560 1 ft 0 in 14.5 ft 0 i None None
4 S=>NE 2 Metal Low-E Single Yes 1.07 0.3 77.98559 1 ft 0 in 14.5 ft 0 i None None
5 S=>NE 2 Metal Low-E Single Yes 1.07 0.3 13.67280 1 ft 0 in 14.5 ft 0 i None None
5/15/2015 11:52 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7
t
i/
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 225 degrees).
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
6 W=>SE 3 Metal Low-E Single Yes 1.07 0.3 58.48919 1 ft 0 in 14.5 ft 0 i None None
7 W=>SE 4 Metal Low-E Single Yes 1.07 0.3 27.34560 13.5 ft 0 i 2 ft 0 in None None
8 W=>SE 4 Metal Low-E Single Yes 1.05 0.28 48 ft2 13.5 ft 0 i 2 ft 0 in None None
9 W=>SE 4 Metal Low-E Single Yes 1 0.32 56 ft2 13.5 ft 0 i 2 ft 0 in None None
10 N=>SW 5 Metal Low-E Single Yes 1.07 0.3 13.67280 1 ft 0 in 14.5 ft 0 i None None
11 N=>SW 6 Metal Low-E Single Yes 1.05 0.28 48 ft2 29.5 ft 0 i 2 ft 0 in None None
12 E=>NW 10 Metal Low-E Single Yes 1 0.32 9 ft2 12 ft 0 in 1 ft 0 in None None
13 E=>NW 10 Metal Low-E Single Yes 1.05 0.28 48 ft2 12 ft 0 in 2.67 ft 0 i None None
14 E=>NW 11 Metal Low-E Single Yes 1 0.3 13.67280 1 ft 0 in 1.33 ft 0 i None None
15 E=>NW 12 Metal Low-E Single Yes 1.05 0.32 9 ft2 7 ft 0 in 1 ft 0 in None None
16 E=>NW 12 Metal Low-E Single Yes 1.05 0.28 48 ft2 7 ft 0 in 2.33 ft 0 i None None
17 S=>NE 13 Metal Low-E Single Yes 1.05 0.28 48 ft2 29.5 ft 0 i 2 ft 0 in None None
18 W=>SE 14 Metal Low-E Single Yes 1.07 0.3 27.34560 13.5 ft 0 i 2 ft 0 in None None
19 W=>SE 14 Metal Low-E Single Yes 1.05 0.28 48 ft2 13.5 ft 0 i 2 ft 0 in None None
20 W=>SE 14 Metal Low-E Single Yes 1 0.32 56 ft2 13.5 ft 0 i 2 ft 0 in None None
21 W=>SE 15 Metal Low-E Single Yes 1.07 0.3 77.98559 1 ft 0 in 14.5 ft 0 i None None
22 W=>SE 15 Metal Low-E Single Yes 1 0.32 77.98559 1 ft 0 in 8 ft 0 in None None
23 W=>SE 15 Metal Low-E Single Yes 1 0.32 77.98559 1 ft 0 in 1.5 ft 0 in None None
24 N=>SW 16 Metal Low-E Single Yes 1.07 0.3 27.34560 1 ft 0 in 14.5 ft 0 i None None
25 N=>SW 16 Metal Low-E Single Yes 1.07 0.3 27.34560 1 ft 0 in 1.5 ft 0 in None None
26 N=>SW 17 Metal Low-E Single Yes 1.07 0.3 38.99279 1 ft 0 in 14.5 ft 0 i None None
27 N=>SW 17 Metal Low-E Single Yes 1.07 0.3 18.36000 1 ft 0 in 14.5 ft 0 i None None
28 E=>NW 20 Metal Low-E Single Yes 1.07 0.3 32.34000 1 ft 0 in 1.5 ft 0 in None None
29 E=>NW 20 Metal Low-E Single Yes 1.07 0.3 96 ft2 1.5 ft 0 in 1.33 ft 0 i None None
30 S=>NE 21 Metal Low-E Single Yes 1.07 0.3 9.180000 1 ft 0 in 1.5 ft 0 in None None
31 S=>NE 21 Metal Low-E Single Yes 1.07 0.3 34.02000 1 ft 0 in 1.5 ft 0 in None None
32 S=>NE 21 Metal Low-E Single Yes 1 0.32 25 ft2 1 ft 0 in 1.5 ft 0 in None None
33 S=>NE 21 Metal Low-E Single Yes 1 0.32 9.486399 1 ft 0 in 1.5 ft 0 in None None
34 W=>SE 22 Metal Low-E Single Yes 1.07 0.3 48.51000 1 ft 0 in 1.5 ft 0 in None None
35 W=>SE 23 Metal Low-E Single Yes 1.07 0.3 32.34000 13.5 ft 0 i 1.5 ft 0 in None None
36 W=>SE 23 Metal Low-E Single Yes 1.05 0.28 48 ft2 13.5 ft 0 i 1.33 ft 0 i None None
37 W=>SE 23 Metal Low-E Single Yes 1 0.32 56 ft2 13.5 ft 0 i 1.33 ft 0 i None None
38 N=>SW 24 Metal Low-E Single Yes 1.07 0.3 22.68000 1 ft 0 in 1.5 ft 0 in None None
39 N=>SW 24 Metal Low-E Single Yes 1.07 0.3 32.34000 1 ft 0 in 1.5 ft 0 in None None
40 N=>SW 24 Metal Low-E Single Yes 1.07 0.3 18.36000 1 ft 0 in 1.5 ft 0 in None None
5/15/2015 11:52 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 1005.984 ft2 1006 ft2 125 ft 10.67 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess 0.000500 8072.3 443.16 833.42 0.4493 7.0798
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8 29.6 kBtu/hr 1 sys#1
2 Electric Heat Pump None HSPF:8 45 kBtu/hr 2 sys#2
3 Electric Heat Pump None HSPF:8 38.5 kBtu/hr 3 sys#3
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER: 14 30 kBtu/hr 900 cfm 0.75 1 sys#1
2 Central Unit None SEER: 14 45.5 kBtu/hr 1365 cfm 0.75 2 sys#2
3 Central Unit None SEER:14 41 kBtu/hr 1230 cfm 0.75 3 sys#3
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.91 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
----Supply---- ----Return---- Air Percent HVAC#
V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool
1 Attic 6 175 ft2 Attic 75 ft2 Default Leakage AC 1 Club (Default) (Default)% 1 1
2 Attic 6 150 ft2 AC 2 Family 15 ft2 Default Leakage AC 3 Secon (Default) (Default)% 2 2
3 Attic 6 275 ft2 Attic 100 ft2 Default Leakage Attic (Default) (Default)% 3 3
5/15/2015 11:52 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7
T
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar A r Ma ri Jun rl
Jul rl
Au rl Se Oct r Nov Dec
Heatin Jan f X Feb f Xj Mar E Apr I
May Jun Jul Au Sep E i Oct [X�Nov H
Dec
Ventin Jan [ Feb X Mar [X A r May Jun Jul Aug Se [X Oct [[[Xlll Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooliing(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
5/15/2015 11:52 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7
r
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT#:
Port St Lucie, FL,
MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details.
COMPONENT SECTION SUMMARYOF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283.Windows and
doors= 0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces:
gasketed doors&outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
controls cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers,filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric)or shutoff(gas). Circulating system pipes insulated to= R-2
+accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per �+
Tables 503.2.3. Equipment efficiency verification required. Special /
equipment occasion cooling or heating capacity requires separate system or JJJ
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
5/15/2015 11:52 AM EnergyGauge®USA-RaRes2010 Section 405.4.1 Compliant Software Page 7 of 7