HomeMy WebLinkAboutSewage PERMIT #:66-SF-1 1309146
- STATE OF FLORIDA APPLICATION #:AP1190 06
•
'a. y
. DEPARTMENT OF HEALTI��LL JUN� 0 MIS DATE PAID
ONSITE SEWAGE TREATMEj ISPOSAE SYSTEM FEE PAID:
CONSTRUCTION PERMIT RECEIPT #:
• w� DOCUMENT #:PR9765 2
lj
CONSTRUCTION PERMIT FOR: OSTDS New
APPLICANT: (Standard Pacific of Florida GP Inc.)
PROPERTY ADDRESS: 3100 NW Radcliffe Way Palm City, FL 34990
LOT: 19 BLOCK: SUBDIVISION: Riverbend
PROPERTY ID #: 442570300240009 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL IND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 1,500 ] GALLONS / GPD Septic CAPACITY
A [ ] GALLONS / GPD N/A CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pum s [ ]
D [ 800 ] SQUARE FEET SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [x] STANDARD [ ] FILLED [ ] MOUND [ ]
I CONFIGURATION: [x] TRENCH [ ] BED [ ]
N
F LOCATION OF BENCHMARK: orange paint on top of catch basin at sw prop.corner of lot 20
I ELEVATION OF PROPOSED SYSTEM SITE [ 15.001 [ INCHES FT ] [ ABOVE BELOW]BENCHMARK/REFERENCE POINT
E BOTTOM OF DRAINFIELD TO BE [ 3.00 ] [ INCHES FT ] [ ABOVE BELOW]BENCHMARK/REFERENCE POINT
L
D FILL REQUIRED: [ 6.001 INCHES EXCAVATION REQUIRED: j 72.00 ] INCHES
The system is sized for 5 bedrooms with a maximum occupancy of 10 persons(2 per bedroom),for a total estimated flow
O of 640 gpd.
T The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with
H s.64E-6.013(3)(0,FAC.
E
R
SPECIFICATIONS BY: rian J Ingram TITLE:
APPROVED BY: .;I TITLE: Environmental Specialist I St. Luci CHD
Ja b K Kirchner
DATE ISSUED: 06/02/2015 EXPIRATION DATE: 12/O /2016
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page of 3
v 1.1.4 AP1190606 SE962229
NOTICE OF RIGHTS
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department,within twenty-one(21)days from the receipt of this order.'The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN#A02, Tallahassee, Florida 32399-1703. The
Agency Clerk's facsimile number is,850-410-1448.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order
will constitute a waiver of your right to an administrative hearing, and this order shall become
a 'final order'.
Should this order become a final order, a party who is adversely affected by it is
entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings
are governed by the Florida Rules of Appellate Procedure. Such proceedings may be
commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the
Department of Health and a second copy, accompanied by the filing fees required by law,
with the Court of Appeal in the appropriate District Court. The notice must be filed within 30
days of rendition of the final order.