Loading...
HomeMy WebLinkAboutSoil Nuclear GaugeSoil Nuclear Gau e g Client: Project: - Report Date: 8/26/2015 Standard Pacific Homes, South Florida .. 13-0183.00 �Arrnn9`'P. Test Method: ASTM D 6938 Riverbend Port St. Lucie St. Lucie: County,. Florida .: FBPE CA # 4930 521 NW Enterprise Drive Port St. Lucie. FL 34986 Phone: 772-924-35751 Fax: 772-924-.3560 Test.Results . . -Test # Retest Of . Test Date Proctor. ID Method Soil. Classification Optimum.- Moisture ("/o) Maximum Dry' Density' (pco _ In Place : Moisture.' _ (%} In Place Dry Density (pcf) Probe Depth (in) -.. Percent . Compaction Min%Ma)i Comp. (%) Remark. 1 8/11/15 P-1 N/A 10.2. 1.16.0 - 7.5 - 117.1 12 101 .95 / 105 Pass 2 8/11/15 P-1. .N/A 10.2.: - 1.16.0 9.8. .113.1 12. - 98' 95/105 .. Pass 3 8/11/15 P-1 N/A. .10.2 116:0. 7.0 117.5 12 101 ' 95 / 105 Pass Test Information Test # . ... . Test Location Elevation Reference Gauge Make / Model / SN .. Field Techniclan' 1 Below Slab Grade: Foundation Pad, Lot No. 19, Southwest Comer 0-1 Troxler f3430,36304 L'iverman, Robert. 2 Below Slab Grade: Foundation Pad, Lot No. 19, Center Area . 0-1 . .: Troxler T3430.36304 Liverrinan, Robert 3 Below Slab Grade: Foundation Pad, Lot No. 19, Northeast Area 0-1 Trokler-T3430 36304 Liveftan, Robert Remarks Comments Related Tests . Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter".. Gauge calibration, data on file with the testing agency. - 1, 2, 3: 1-- 2 HCP=70, > 95 %.Compaction, PASS. HCP tests are' empirically Correlated to the relative derisitV of the soil. Test # Related Test # TesY Type