HomeMy WebLinkAboutSoil Nuclear GaugeSoil Nuclear Gau e
g Client: Project: -
Report Date: 8/26/2015 Standard Pacific Homes, South Florida .. 13-0183.00
�Arrnn9`'P. Test Method: ASTM D 6938 Riverbend
Port St. Lucie St. Lucie: County,. Florida .:
FBPE CA # 4930
521 NW Enterprise Drive
Port St. Lucie. FL 34986
Phone: 772-924-35751 Fax: 772-924-.3560
Test.Results . .
-Test #
Retest
Of .
Test
Date
Proctor. ID
Method
Soil.
Classification
Optimum.-
Moisture
("/o)
Maximum
Dry' Density'
(pco _
In Place
: Moisture.'
_ (%}
In Place
Dry Density
(pcf)
Probe
Depth
(in) -..
Percent
. Compaction
Min%Ma)i
Comp.
(%)
Remark.
1
8/11/15
P-1
N/A
10.2.
1.16.0
- 7.5
- 117.1
12
101
.95 / 105
Pass
2
8/11/15
P-1.
.N/A
10.2.:
- 1.16.0
9.8.
.113.1
12. -
98'
95/105 ..
Pass
3
8/11/15
P-1
N/A.
.10.2
116:0.
7.0
117.5
12
101 '
95 / 105
Pass
Test Information
Test #
. ... .
Test Location
Elevation
Reference
Gauge
Make / Model / SN ..
Field Techniclan'
1
Below Slab Grade: Foundation Pad, Lot No. 19, Southwest Comer
0-1
Troxler f3430,36304
L'iverman, Robert.
2
Below Slab Grade: Foundation Pad, Lot No. 19, Center Area .
0-1 . .:
Troxler T3430.36304
Liverrinan, Robert
3
Below Slab Grade: Foundation Pad, Lot No. 19, Northeast Area
0-1
Trokler-T3430 36304
Liveftan, Robert
Remarks
Comments
Related Tests .
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter"..
Gauge calibration, data on file with the testing agency. -
1, 2, 3: 1-- 2 HCP=70, > 95 %.Compaction, PASS. HCP tests are' empirically
Correlated to the relative derisitV of the soil.
Test #
Related Test #
TesY Type