Loading...
HomeMy WebLinkAboutDURDEN RES TRUSS LAYOUT ESS 11-12-21 CAUTION ! ! ! DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND 56' 011 BSCI-131 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE 11l 101, 161 011 281 211 IN PLACE PRIOR TO LOADING TRUSSES. (ie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. M LO ti ti LO M yV W W REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 7 1) NUMBER OF GIRDER PLIES AND CA CJ1 NAILING SCHEDULE. Hatch Legend 2) BEARING BLOCK REQUIREMENTS. CJ3 � o � o CJ3 3) SCAB DETAILS (IF REQUIRED) O Oo 4) UPLIFT AND GRAVITY REACTIONS. bo CJ5 � N > CJ5 BO ' � " AOFOF WARNING cry LO o co LO LO c Backcharges Will Not Be Accepted U Q C 1 co ti oo rn y U U Q '` v Q Q Q Q Q Q Q Q Q Q U U U �.' Regardless of Fault Without Prior U') L U") LO Notification By Customer Within 48 Q Q Q Q Q Q Q Q Hours And Investigation By Builders FirstSource. CA V CA NO EXCEPTIONS. The General Contractor Is Responsible TRUSS END DETAIL For All Connections Other Than Truss CJ3 V > - CJ3 to Truss, Gable Shear Wall, And Connections. Temporary and U Permanent Bracing, And Ceiling And CJ5 V z - CJ5 12 Roof Diaphragm Connections. PLUMB CUT OVERHANG 6 U EJ7 EJ7 co EJ7 a foil 1 011 1 0if 1 oll 1 oll 1 oll 1 oll 1 011 1 011 1 oll 1 oll oll oll oll oll oll oll oll oll oll W o EJ7 HEEL HEIGHT 7, o,� 71 0 11 EP �> EJ7 EJ7 EJ7 o EJ7 0 N PAUL WELCH INC. 1984 SW BILTMORE ST - #114 EJ7 PORT ST LUCIE, FL 34984 FL EJ7 REG N0. 29945 > EJ71 EJ7 z \ // \ / o REVIEWED BY: x - 0 U I \ // U /�\ EJ71 cn Digitally signed EJ7 U w z \,� \�/ Pa u I by Paul Welch Date: CJ5 Q Q �\ /x� L % % > EJ71 Welch 10:16:0612 ap \ LL \\ \ 10:16:06 05'00' �LL/ \// BUILDER: v\\ \ EJ71 CJ3 a PSL PROPERTIES \ RES- DURDEN V EJ7 CA j j j j jIr L0 ADDRESS: 5113 SUNSET BLVD > > AHU o D1 <11 LOT / BLOCK: -- � B2 11 211 COUNTY: ST LUCIE in o B2 M O - CITY: FORT PIERCE CA In D RAW N BY: J L o B2 JOB # : 2881008 DATE: 08/23/21 SCALE: NTS in U w w - 1> B3 0 B4 REVISIONS: 1. 2. 3. MAIN WIND FORCE RESISTING SYSTEM/C-C HYBRID IMPORTANT WIND ASCE7-16 4. ENCLOSED This Drawing Must Be Approved And EXPOSURE CATEGORY C Returned Before Fabrication Will 281411 81011 191811 OCCUPANCY CATEGORY II Begin. For Your Protection Check All WIND LOAD 160 MPH Dimensions And Conditions Prior To 011ders *TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSF Approval Of Plan. BOTTOM CHORD LIVE LOAD NONCONCURRENT WITH 561011 ANY OTHER LIVE LOADS SIGNATURE BELOW INDICATES ALL FirstSource NOTES AND DIMENSIONS HAVE ROOF LOADING FLOOR LOADING BEEN ACCEPTED. TCLL: 20 PSF TCLL: PSF 701 S. KINGS HIGHWAY TCDL: 07 PSF TCDL: PSF FORT PIECE, FL 34945 BCDL: 10 PSF BCDL: PSF By Date Ph. (772) - 461 5475 TOTAL: 37 PSF TOTAL: PSF DURATION: 1.25 DURATION: