Loading...
HomeMy WebLinkAboutShingle (16) BCI6 HRPH LRJ IQ 8VHU 5HJLVWUDWLRQ HRW 7RSLFV 6XEPLW 6XUFKDUJH 6WDWV & FDFWV 3XEOLFDWLRQV CRQWDFW 8V BCI6 6LWH MDS LLQNV 6HDUFK PURdXcW ASSURYal USER: 3XEOLF 8VHU 3URGXFW ASSURYDO MHQX > 3URGXFW RU ASSOLFDWLRQ 6HDUFK > ASSOLFDWLRQ LLVW > ASSOicaWiRQ DeWaiO FL #FL10674-R16 Application T\pe ReYision Code Version 2020 Application StatXs ApproYed Comments ArchiYed ProdXct ManXfactXrer OZens Corning Address/Phone/Email One OZens Corning ParkZa\ Toledo, OH 43659 (740) 404-7829 greg.keeler@oZenscorning.com AXthori]ed SignatXre Greg Keeler greg.keeler@oZenscorning.com Technical RepresentatiYe Mel Sancrant Address/Phone/Email 1 OZens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@oZenscornig.com QXalit\ AssXrance RepresentatiYe Address/Phone/Email Categor\Roofing SXbcategor\Asphalt Shingles Compliance Method EYalXation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer EYalXation Report - Hardcop\ ReceiYed Florida Engineer or Architect Name Zho deYeloped the EYalXation Report Robert J.M. Nieminen Florida License PE-59166 QXalit\ AssXrance Entit\PRI ConstrXction Materials Technologies, LLC QXalit\ AssXrance Contract E[piration Date 01/01/2099 Validated B\John W. Kne]eYich, PE Validation Checklist - Hardcop\ ReceiYed Certificate of Independence FL10674_R16_COI_2020_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)SWaQdaUd YeaU ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2019 EqXiYalence of ProdXct Standards Certified B\ Sections from the Code ProdXct ApproYal Method Method 1 Option D Date SXbmitted 12/11/2020 Date Validated 12/17/2020 Date Pending FBC ApproYal 12/26/2020 Date ApproYed 02/09/2021 SXmmaU\ Rf PURdXcWV FL #MRdel, NXmbeU RU Name DeVcUiSWiRQ 10674.1 OZens Corning Asphalt Roofing Shingles and Starters 3-tab, 4-tab, laminated, starter and hip & ridge shingles LimiWV Rf UVe ASSURYed fRU XVe iQ HVHZ: No ASSURYed fRU XVe RXWVide HVHZ: Yes ImSacW ReViVWaQW: N/A DeVigQ PUeVVXUe: N/A OWheU: Refer to ER, Section 5. IQVWallaWiRQ IQVWUXcWiRQV FL10674_R16_II_2020_12_11_FINAL_ER_OC_ASPHALT SHINGLES_FL10674-R16.pdf Verified B\: Robert J. M. Nieminen PE - 59166 Created b\ Independent Third Part\: Yes EYalXaWiRQ ReSRUWV FL10674_R16_AE_2020_12_11_FINAL_ER_OC_ASPHALT SHINGLES_FL10674-R16.pdf Created b\ Independent Third Part\: Yes BacN Ne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dXcW ASSURYaO AcceSWV: NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 Evaluation Report O37940.02.12-R11 FL10674-R16 Date of Issuance: 02/06/2012 Revision 11: 12/11/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The FůŽƌŝda PƌŽdƵcƚ AƉƉƌŽǀaů NƵŵbeƌ ;FLηͿ Ɖƌeceded bLJ ƚhe ǁŽƌdƐ ͞NEMOͮeƚc͘ EǀaůƵaƚed͟ ŵaLJ be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12/11/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 2 of 10 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 3. REFERENCES: Entity Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Standard Description Accessory Starter Strips Starter Strip Shingle H-TX, OR ASTM D3462 starter strips for asphalt roof shingles Starter Strip Plus MN, OR SRS TopShield Starter MN, OR Starter Shingle Roll NH ASTM D1970 mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter Asphalt Shingles Supreme® GA, CA, CO, I-TX, NJ, OH, TN, OR, IL ASTM D3462 fiberglass reinforced 3-tab asphalt roof shingles Berkshire® MN ASTM D3462 fiberglass reinforced, 4-tab asphalt roof shingles Duration® Premium CA, OR ASTM D3462 fiberglass reinforced, laminated asphalt roof shingles Duration® Premium COOL CA TruDefinition® Duration® IN, CA, CO, I-TX, FL, NJ, OH, MN, OR, GA, IL, TN TruDefinition® Duration® Designer Color Collection Oakridge® GA, IN, CA, CO, H-TX, I-TX, FL, NJ OH, TN TruDefinition® Oakridge® H-TX, I-TX WeatherGuard® HP TN NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 3 of 10 TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Standard Description Hip and Ridge Shingles Berkshire® Hip and Ridge Shingles with Sealant MN ASTM D3462 fiberglass reinforced, hip and ridge asphalt roof shingles DuraRidge® Hip and Ridge Shingles with Sealant MN ProEdge® GA, CA, OH, OR WeatherGuard® HP Hip and Ridge Shingles TN 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Supreme® ASTM D3161(F) & ASTM D7158(H) Berkshire® Duration® Premium Duration® Premium COOL TruDefinition® Duration® TruDefinition® Duration® Designer Color Collection Oakridge® TruDefinition® Oakridge® WeatherGuard® HP 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 4 of 10 TABLE 2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE Type Product FBC Table 1507.2.7.1 or R905.2.6.1 Starter Strips Starter Strip Shingle ASTM D3161, Class F Starter Strip Plus SRS TopShield Starter Hip & Ridge Shingles Berkshire® Hip and Ridge Shingles with Sealant ASTM D3161, Class F DuraRidge® Hip and Ridge Shingles with Sealant ProEdge® WeatherGuard® HP Hip and Ridge Shingles 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacƚƵƌeƌ͛Ɛ minimƵm ƌeqƵiƌemenƚƐ͘ 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufactureƌ͛Ɛ pƵbliƐhed ƌeqƵiƌemenƚƐ͕ bƵƚ noƚ leƐƐ ƚhan FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear-off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 5 of 10 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ¾ Berkshire® shingles require minimum five (5) nails per shingle. ¾ WeatherGuard® HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Figure 4: Minimum Nailing, Supreme (Standard Size) Figure 5: Minimum Nailing, Supreme (Metric Size) NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 6 of 10 6.3.1.2 Berkshire®: Figure 6: 5-Nail Pattern, Berkshire Figure 7: 6-Nail Pattern, Berkshire Figure 8: Mansard or Steep Slope Pattern, Berkshire NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 7 of 10 6.3.1.3 Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinition® Duration® Designer Color Collection: Figure 9: Standard 4-Nail Pattern, Duration Figure 10: 6-Nail Pattern, Duration Figure 11: Mansard or Steep Slope Pattern, Duration NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 8 of 10 6.3.1.4 TruDefinition® Oakridge®, Oakridge®: Figure 12: Standard 4-Nail Pattern, Oakridge Figure 13: 6-Nail Pattern, Oakridge Figure 14: Mansard or Steep-Slope Pattern, Oakridge 6.3.1.5 WeatherGuard® HP: Figure 15: 6-Nail Pattern, WeatherGuard HP Figure 16: Mansard or Steep-Slope Pattern, WeatherGuard HP NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 9 of 10 6.4 HIP AND RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ¾ Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. ¾ WeatherGuard® HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant: Figure 17: Isometric View, Berkshire and DuraRidge Figure 18: Plan View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard® HP Hip and Ridge Shingles: Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20: Plan View, WeatherGuard HP Hip and Ridge NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R11 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 10 of 10 6.4.1.3 ProEdge®: Figure 21: Isometric View, ProEdge Figure 22: Plan View, ProEdge 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLCʹ QUA9110 ; (813) 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT -