HomeMy WebLinkAboutEnergy Efficiency Coderi'
FORM R405-2020
C:i n01111e PKMP ,v 1=1z1=1r_A1=Nc'v r.nDF FOR BUILDING CONSTRUCTION
i
r
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Monaco Residence
Builder Name-
Street: XXX Soulhwind Trail
Permit Office: St. Lucie County
City, State, Zip- Fort Pierce. FL . 34951
Permit Number
Owner: Jesus Monaco
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV081.3 sgft.)
Insulation Area
a. Concrete Block - int Insui. Exterior
R=4.1 1703.30 ft'
2. Single Tamil or multiple family Detached
9 y p 5
b. Frame - Wood. Adjacent
R=11.0 378.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 3
d. NIA
R= ft'
11. Ceiling Types (2294.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2294.00 ft'
6. Conditioned floor area above grade (ft-) 2294
b. NIA
R= ft'
Conditioned floor area below grade (W) 0
c. N/A
R= W
12. Ducts
R ft2
7. Windows(229.0 sgfl.) Description Area
a. Sup. Attic, Re(: Attic. AH: Garage
6 85
a. U-Factor: Sgl. U=0.65 229.00 ft'
SHGC: SHGC=0.25
b. U-Factor: N/A ft'
13. Cooling systems
kBtu`hr Efficiency
SHGC:
a. Central Unit
41.5 SEER:16.00
c. U-Factor: NIA ft'
SHGC:
Area Weighted Average Overhang Depth: 6.269 ft.
14. Heating systems
a. Electric Strip Heat
kBtutnr Efficiency
34.0 COP:1.00
Area Weighted Average SHGC: 0.250
8. Skylights Area
c. U-Factor:(AVG) N/A ft'
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 50 gallons
9. Floor Types (2294.0 sgft-) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2294.00 ft'
b. Conservation features
b. N/A R= It'
None
c. N/A R= ft'
16. Credos
CF. Pstat
Total Proposed Modified Loads: 65.56
®®S
Glass/Floor Area: 0.100
Total Baseline Loads: 65.89
�'"�e7S�aa
I hereby certify that the plans and specifications covered by
Review of the plans and
•ram===�_..-
; ft THE 5�7•
this calculation are in compliance with the Florida Energy
specifications covered by this
��'=" `'
Code.
calculation indicates compliance
P
�1•
t-r ''1 =-'• ; = :'':: , f �
with the Florida Energy Code.
.! 1_4' •. •.`;:.•: ':.' .: •`.=: O r
PREPARED BY: -- -- -
Before construction is completed
P
C
DATE: - ----
this building will be inspected for
9 p
compliance with Section 553.908
Florida Statutes.
:a,i�'
. `- �'
_7-2
I hereby certify that thi •Idi designed: is in compliance
:.
` OU
with the Florida E gy C e.
= tti'T.��,
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
___ �_
--__
Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1•
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
J
7/22/2021 7:20 PM EnergyGaugeCR: USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Monaco Residence
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2294
Lot #
Owner Name:
Jesus Monaco
Total Stories: 1
Block/SubdNision:
# of Units:
1
Worst Case: No
PlatBook:
,Builder Name:
Rotate Angle: 0
Street:
XXX Southwind
Trail
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
,Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2294
22716.6
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
Master Bedroom
287
3444 No
2
1
1
Yes
Yes
Yes
2
Hall
24
216 No
0
1
No
Yes
Yes
3
M WIC
81
729 No
0
1
No
Yes
Yes
4
Master Bath
169
1521 No
0
1
Yes
Yes
Yes
5
Dining
96
864 No
0
1
Yes
Yes
Yes
6
Kitchen
144
1296 Yes
1
1
Yes
Yes
Yes
7
Great Room
504
5745.6 No
2
1
Yes
Yes
Yes
8
Office
255
2295 No
1
1
Yes
Yes
Yes
9
Bedroom 2
187
1683 No
1
1
1
Yes
Yes
Yes
10
Bath 2
.54
486 No
0
1
Yes
Yes
Yes
11
Bedroom 3
184
1656 No
2
1
1
Yes
Yes
Yes
12
Hall
156
1404 No
0
1
No
Yes
Yes
13
Laundry
63
567 No
0
1
No
Yes
Yes
14
Pantry
36
324 No
0
1
No
Yes
Yes
15
Bath 3
54
486 No
0
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio Master Bedroom 40 ft
287 ft2
----
1 0
0
2 Slab -On -Grade Edge Insulatio
Hall
2 1 ft
24 ft2
----
1 0
0
3 Slab -On -Grade Edge Insulatio
M WIC 1 ft
81 ft2
----
1 0
0
7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Paget of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
{
4 Slab -On -Grade Edge Insulatio
Master Bath 27 ft
169 ft2
----
1
0
0
w:
5 Slab -On -Grade Edge Insulatio
Dining 8 ft
96 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
Kitchen 12 ft
144 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulatio
Great Room 24 ft
504 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulatio
Office 15 ft
255 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulatio
Bedroom 2 28 ft
187 ft2
----
1
0
0
10SIab-On-Grade Edge Insulatio
Bath 2 6 ft
54 ft2
—
1
0
0
11Slab-On-Grade Edge Insulatio
Bedroom 3 13 ft
184 ft2
----
1
0
0
12SIab-On-Grade Edge Insulatio
Hall 1 1 ft
156 ft2
----
1
0
0
13SIab-On-Grade Edge Insulatio
Laundry 1 ft
63 ft2
----
1
0
0
14SIab-On-Grade Edge Insulatio
Pantry 1 ft
36 ft2
----
1
0
0
15SIab-On-Grade Edge Insulatio
Bath 3 3 ft
54 ft2
----
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials
Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 2485 ft2
0 ft2
Light
N
0.6
No 0.9
No 0
22.62
ATTIC
Area
RBS
IRCC
V
# Type
Ventilation
Vent Ratio (1 in)
1 Full attic
Vented
150
2294 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
Master Bedroom
30
Batt
287 ft2
0.1
Wood
2 Under Attic (Vented)
Hall 2
30
Batt
24 ft2
0.1
Wood
3 Under Attic (Vented)
M WIC
30
Batt
81 ft2
0.1
Wood
4 Under Attic (Vented)
Master Bath
30
Batt
169 ft2
0.1
Wood
5 Under Attic (Vented)
Dining
30
Batt
96 ft2
0.1
Wood
6 Under Attic (Vented)
Kitchen
30
Batt
144 ft2
0.1
Wood
7 Under Attic (Vented)
Great Room
30
Batt
504 ft2
0
Wood
8 Under Attic (Vented)
Office
30
Batt
255 ft2
0.1
Wood
9 Under Attic (Vented)
Bedroom 2
30
Batt
187 ft2
0.1
Wood
10 Under Attic (Vented)
Bath 2
30
Batt
54 ft2
0.1
Wood
11 Under Attic (Vented)
Bedroom 3
30
Batt
184 ft2
0.1
Wood
12 Under Attic (Vented)
Hall 1
30
Batt
156 ft2
0.1
Wood
13 Under Attic (Vented)
Laundry
30
Batt
63 ft2
0.1
Wood
14 Under Attic (Vented)
Pantry
30
Batt
36 ft2
0.1
Wood
�L
15 Under Attic (Vented)
Bath 3
30
Batt
54 ft2
0.1
Wood
7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Below
SpaceR-Nblhle
le
Et
n
Et
n
Area
on
sor
1
N
Exterior
Concrete Block - Int InsMaster Bedro
4.1
23
0
12
0
276.0 ft2
0
0
0.4
0
2
E
Exterior
Concrete Block - Int InsMaster Bedro
4.1
17
0
12
0
204.0 ft2
0
0
0.4
0
3
N
Exterior
Concrete Block - Int InsWaster Bath
4.1
10
0
9
0
90.0 ft2
0
0
0.4
0
4
W
Exterior
Concrete Block - Int Insdlllaster Bath
4.1
17
0
9
0
153.0 ft2
0
0
0.4
0
5
. E
Exterior
Concrete Block - Int Insul Dining
4.1
8
0
9
0
72.0 ft2
0
0
0.4
0
6
E
Exterior
Concrete Block - Int Insul Kitchen
4.1
12
0
9
0
108.0 ft2
0
0
0.4
0
7
W
Exterior
Concrete Block - Int Insu3reat Room
4.1
19
0
11
4
215.3 ft2
0
0
0.4
0
8
W
Exterior
Concrete Block - Int Insul Office
4.1
15
0
9
0
135.0 ft2
0
0
0.4
0
9
S
Exterior
Concrete Block - Int InsuBedroom 2
4.1
15
0
9
0
135.0 ft2
0
0
0.4
0
10
W
Exterior
Concrete Block - Int InsuBedroom 2
4.1
13
0
9
0
117.0 ft2
0
0
0.4
0
11
S
Exterior
Concrete Block - Int Insul Bath 2
4.1
6
0
9
0
54.0 ft2
0
0
0.4
0
12
S
Exterior
Concrete Block - Int InsuBedroom 3
4.1
13
0
9
0
117.0 ft2
0
0
0.4
0
13
N
Exterior
Concrete Block - Int Insul Bath 3
4.1
3
0
9
0
27.0 ft2
0
0
0.4
0
_ 14
E
Garage
Frame - Wood Bath 3
11
6
9
54.0 ft2
0.23
0.4
0
15
E
Garage
Frame - Wood Hall 1
11
4
9
36.0 ft2
0.23
0.4
0
16
S
Garage
Frame - Wood Hall 1
11
6
9
54.0 ft2
0.23
0.4
0
_ 17
E
Garage
Frame - Wood Laundry
11
7 '
9
63.0 ft2
0.23
0.4
0
18
E
Garage
Frame - Wood Bedroom 3
11
2
9
18.0 ft2
0.23
0.4
0
19
N
Garage
Frame - Wood Bedroom 3
11
4
9
36.0 ft2
0.23
0.4
0
_ 20
E
Garage
Frame - Wood Bedroom 3
11
13
9
117.0 ft2
0.23
0.4
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated Great Room
None
.39
6
8
48 ft2
2
S
Insulated Hall 1
None
.39
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E 2
Metal Low-E Single Yes
0.65
0.25
Y
48.0 ft2
8 ft 0 in
1 ft 4 in
None
None
2
N 3
Metal Low-E Single Yes
0.65
0.25
Y
8.0 ft2
1 ft 6 in
1 ft 4 in
None
None
3
W 4
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
4
E 5
Metal Low-E Single Yes
0.65
0.25
Y
48.0 ft2
8 ft 0 in
1 ft 4 in
None
None
5
E 6
Metal Low-E Single Yes
0.65
0.25
Y
12.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6
W 7
Metal Low-E Single Yes
0.65
0.25
Y
30.0 ft2
8 ft 0 in
1 ft 4 in
None
None
7
W 8
Metal Low-E Single Yes
0.65
0.25
Y
30.0 ft2
8 ft 0 in
1 ft 4 in
None
None
8
W 10
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
9
S 11
Metal Low-E Single Yes
0.65
0.25
Y
8.0 ft2
1 ft 6 in
1 ft 4 in
None
None
10
S 12
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R4'05-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
832 ft2
832 ft2
42 ft 9 ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000377
2271.7 124.63 233.98 .1179 6
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 41.5 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 85 ft2
Attic
20 ft2 Default Leakage Garage (Default) (Default)
1 1
7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R4105-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoollnDenting
May
Jul
Aug
Sep
Oct
Nov
Dec
Jan JX�Feb
�Xj Mar
�(�
Apr
May
Jun
ri Jun
Jul
ri
Aug
Sep
Oct
Dec
LX�
[
[
lX�
lXNov
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0. ft2
0 ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft..
ft2
ft
0.3
Great Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Office
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/s .ft.
ft2
ft
0.3
Bath 3