HomeMy WebLinkAboutEnergy Efficiency Coderi' FORM R405-2020 C:i n01111e PKMP ,v 1=1z1=1r_A1=Nc'v r.nDF FOR BUILDING CONSTRUCTION i r Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Monaco Residence Builder Name- Street: XXX Soulhwind Trail Permit Office: St. Lucie County City, State, Zip- Fort Pierce. FL . 34951 Permit Number Owner: Jesus Monaco Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV081.3 sgft.) Insulation Area a. Concrete Block - int Insui. Exterior R=4.1 1703.30 ft' 2. Single Tamil or multiple family Detached 9 y p 5 b. Frame - Wood. Adjacent R=11.0 378.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. NIA R= ft' 11. Ceiling Types (2294.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2294.00 ft' 6. Conditioned floor area above grade (ft-) 2294 b. NIA R= ft' Conditioned floor area below grade (W) 0 c. N/A R= W 12. Ducts R ft2 7. Windows(229.0 sgfl.) Description Area a. Sup. Attic, Re(: Attic. AH: Garage 6 85 a. U-Factor: Sgl. U=0.65 229.00 ft' SHGC: SHGC=0.25 b. U-Factor: N/A ft' 13. Cooling systems kBtu`hr Efficiency SHGC: a. Central Unit 41.5 SEER:16.00 c. U-Factor: NIA ft' SHGC: Area Weighted Average Overhang Depth: 6.269 ft. 14. Heating systems a. Electric Strip Heat kBtutnr Efficiency 34.0 COP:1.00 Area Weighted Average SHGC: 0.250 8. Skylights Area c. U-Factor:(AVG) N/A ft' 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (2294.0 sgft-) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2294.00 ft' b. Conservation features b. N/A R= It' None c. N/A R= ft' 16. Credos CF. Pstat Total Proposed Modified Loads: 65.56 ®®S Glass/Floor Area: 0.100 Total Baseline Loads: 65.89 �'"�e7S�aa I hereby certify that the plans and specifications covered by Review of the plans and •ram===�_..- ; ft THE 5�7• this calculation are in compliance with the Florida Energy specifications covered by this ��'=" `' Code. calculation indicates compliance P �1• t-r ''1 =-'• ; = :'':: , f � with the Florida Energy Code. .! 1_4' •. •.`;:.•: ':.' .: •`.=: O r PREPARED BY: -- -- - Before construction is completed P C DATE: - ---- this building will be inspected for 9 p compliance with Section 553.908 Florida Statutes. :a,i�' . `- �' _7-2 I hereby certify that thi •Idi designed: is in compliance :. ` OU with the Florida E gy C e. = tti'T.��, OWNER/A BUILDING OFFICIAL: DATE: DATE: ___ �_ --__ Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1• - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). J 7/22/2021 7:20 PM EnergyGaugeCR: USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Monaco Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2294 Lot # Owner Name: Jesus Monaco Total Stories: 1 Block/SubdNision: # of Units: 1 Worst Case: No PlatBook: ,Builder Name: Rotate Angle: 0 Street: XXX Southwind Trail Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , ,Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2294 22716.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 287 3444 No 2 1 1 Yes Yes Yes 2 Hall 24 216 No 0 1 No Yes Yes 3 M WIC 81 729 No 0 1 No Yes Yes 4 Master Bath 169 1521 No 0 1 Yes Yes Yes 5 Dining 96 864 No 0 1 Yes Yes Yes 6 Kitchen 144 1296 Yes 1 1 Yes Yes Yes 7 Great Room 504 5745.6 No 2 1 Yes Yes Yes 8 Office 255 2295 No 1 1 Yes Yes Yes 9 Bedroom 2 187 1683 No 1 1 1 Yes Yes Yes 10 Bath 2 .54 486 No 0 1 Yes Yes Yes 11 Bedroom 3 184 1656 No 2 1 1 Yes Yes Yes 12 Hall 156 1404 No 0 1 No Yes Yes 13 Laundry 63 567 No 0 1 No Yes Yes 14 Pantry 36 324 No 0 1 No Yes Yes 15 Bath 3 54 486 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bedroom 40 ft 287 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio Hall 2 1 ft 24 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio M WIC 1 ft 81 ft2 ---- 1 0 0 7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Paget of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet { 4 Slab -On -Grade Edge Insulatio Master Bath 27 ft 169 ft2 ---- 1 0 0 w: 5 Slab -On -Grade Edge Insulatio Dining 8 ft 96 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio Kitchen 12 ft 144 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulatio Great Room 24 ft 504 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio Office 15 ft 255 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 2 28 ft 187 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Bath 2 6 ft 54 ft2 — 1 0 0 11Slab-On-Grade Edge Insulatio Bedroom 3 13 ft 184 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Hall 1 1 ft 156 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulatio Laundry 1 ft 63 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulatio Pantry 1 ft 36 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulatio Bath 3 3 ft 54 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2485 ft2 0 ft2 Light N 0.6 No 0.9 No 0 22.62 ATTIC Area RBS IRCC V # Type Ventilation Vent Ratio (1 in) 1 Full attic Vented 150 2294 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Master Bedroom 30 Batt 287 ft2 0.1 Wood 2 Under Attic (Vented) Hall 2 30 Batt 24 ft2 0.1 Wood 3 Under Attic (Vented) M WIC 30 Batt 81 ft2 0.1 Wood 4 Under Attic (Vented) Master Bath 30 Batt 169 ft2 0.1 Wood 5 Under Attic (Vented) Dining 30 Batt 96 ft2 0.1 Wood 6 Under Attic (Vented) Kitchen 30 Batt 144 ft2 0.1 Wood 7 Under Attic (Vented) Great Room 30 Batt 504 ft2 0 Wood 8 Under Attic (Vented) Office 30 Batt 255 ft2 0.1 Wood 9 Under Attic (Vented) Bedroom 2 30 Batt 187 ft2 0.1 Wood 10 Under Attic (Vented) Bath 2 30 Batt 54 ft2 0.1 Wood 11 Under Attic (Vented) Bedroom 3 30 Batt 184 ft2 0.1 Wood 12 Under Attic (Vented) Hall 1 30 Batt 156 ft2 0.1 Wood 13 Under Attic (Vented) Laundry 30 Batt 63 ft2 0.1 Wood 14 Under Attic (Vented) Pantry 30 Batt 36 ft2 0.1 Wood �L 15 Under Attic (Vented) Bath 3 30 Batt 54 ft2 0.1 Wood 7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceR-Nblhle le Et n Et n Area on sor 1 N Exterior Concrete Block - Int InsMaster Bedro 4.1 23 0 12 0 276.0 ft2 0 0 0.4 0 2 E Exterior Concrete Block - Int InsMaster Bedro 4.1 17 0 12 0 204.0 ft2 0 0 0.4 0 3 N Exterior Concrete Block - Int InsWaster Bath 4.1 10 0 9 0 90.0 ft2 0 0 0.4 0 4 W Exterior Concrete Block - Int Insdlllaster Bath 4.1 17 0 9 0 153.0 ft2 0 0 0.4 0 5 . E Exterior Concrete Block - Int Insul Dining 4.1 8 0 9 0 72.0 ft2 0 0 0.4 0 6 E Exterior Concrete Block - Int Insul Kitchen 4.1 12 0 9 0 108.0 ft2 0 0 0.4 0 7 W Exterior Concrete Block - Int Insu3reat Room 4.1 19 0 11 4 215.3 ft2 0 0 0.4 0 8 W Exterior Concrete Block - Int Insul Office 4.1 15 0 9 0 135.0 ft2 0 0 0.4 0 9 S Exterior Concrete Block - Int InsuBedroom 2 4.1 15 0 9 0 135.0 ft2 0 0 0.4 0 10 W Exterior Concrete Block - Int InsuBedroom 2 4.1 13 0 9 0 117.0 ft2 0 0 0.4 0 11 S Exterior Concrete Block - Int Insul Bath 2 4.1 6 0 9 0 54.0 ft2 0 0 0.4 0 12 S Exterior Concrete Block - Int InsuBedroom 3 4.1 13 0 9 0 117.0 ft2 0 0 0.4 0 13 N Exterior Concrete Block - Int Insul Bath 3 4.1 3 0 9 0 27.0 ft2 0 0 0.4 0 _ 14 E Garage Frame - Wood Bath 3 11 6 9 54.0 ft2 0.23 0.4 0 15 E Garage Frame - Wood Hall 1 11 4 9 36.0 ft2 0.23 0.4 0 16 S Garage Frame - Wood Hall 1 11 6 9 54.0 ft2 0.23 0.4 0 _ 17 E Garage Frame - Wood Laundry 11 7 ' 9 63.0 ft2 0.23 0.4 0 18 E Garage Frame - Wood Bedroom 3 11 2 9 18.0 ft2 0.23 0.4 0 19 N Garage Frame - Wood Bedroom 3 11 4 9 36.0 ft2 0.23 0.4 0 _ 20 E Garage Frame - Wood Bedroom 3 11 13 9 117.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Great Room None .39 6 8 48 ft2 2 S Insulated Hall 1 None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Metal Low-E Single Yes 0.65 0.25 Y 48.0 ft2 8 ft 0 in 1 ft 4 in None None 2 N 3 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 1 ft 6 in 1 ft 4 in None None 3 W 4 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 6 in 1 ft 4 in None None 4 E 5 Metal Low-E Single Yes 0.65 0.25 Y 48.0 ft2 8 ft 0 in 1 ft 4 in None None 5 E 6 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 8 ft 0 in 1 ft 4 in None None 6 W 7 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 8 ft 0 in 1 ft 4 in None None 7 W 8 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 8 ft 0 in 1 ft 4 in None None 8 W 10 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 6 in 1 ft 4 in None None 9 S 11 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 1 ft 6 in 1 ft 4 in None None 10 S 12 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 6 in 1 ft 4 in None None 7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R4'05-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 832 ft2 832 ft2 42 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000377 2271.7 124.63 233.98 .1179 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 41.5 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # ---- Supply ---- Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 85 ft2 Attic 20 ft2 Default Leakage Garage (Default) (Default) 1 1 7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R4105-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoollnDenting May Jul Aug Sep Oct Nov Dec Jan JX�Feb �Xj Mar �(� Apr May Jun ri Jun Jul ri Aug Sep Oct Dec LX� [ [ lX� lXNov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0. ft2 0 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft.. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Office Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/s .ft. ft2 ft 0.3 Bath 3 7/22/2021 7:20 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6